E18-0068_Ford Amp Catwalk Panel E10_1525204159.pdf
*siti OF go it".•.1% m. PANEL SDP PANEL CATWALK S°' ELECTRICALLEGEND PROJECT: FORD AMPHITHEATER ENGINEER: SOH PROJECT:FORD AMPHITHEATER ENGINEER: SOH 05/01/18 (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) PROJECT#: 18018 VOLTAGE: 120/208V,3P,4W PROJECT#: 18018 VOLTAGE: 120/208V,3P,4W MOUNTING:SURFACE MAINS: 600A MLO MOUNTING:SURFACE MAINS: 200A MLO Q RECESSED OR SURFACE DOWNLIGHT ABBREVIATIONS TYPE:SQUARE D NQOD NEMA 3R AIC: 10K TYPE:SQUARE D NQOD NEMA 3R AIC: 10K 0-1 WALL MOUNTED LIGHT FIXTURE AC ABOVE COUNTER PHASE PHASE PHASE PHASE RECESSED FLUOR.LIGHT FIXTURE AFF -ABOVE FINISHED FLOOR DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION Aa AFG -ABOVE FINISHED GRADE SURFACE FLUOR.LIGHT FIXTURE AHJ -AUTHORITY HAVING JURISDICTION STAGE RIGHT 200A#2 18050 200 3 1 2 0 SPACE HUBBELL HOIST CONTROLS 2407 30 3 1 _2 1 20 720 RECEPTACLES Aa AL -ALUMINUM FIXTURE DESIGNATIONS: CU -COPPER 18050 3 4 0 SPACE " 2407 3 4 1 20 720 RECEPTACLES UPPER CASE-FIXTURE TYPE EC -ELECTRICAL CONTRACTOR " 18050 5 6 0 SPACE II 2407 5 6 1 20 720 RECEPTACLES LOWER CASE-SWITCH DESIGNATION EM -EMERGENCY II - O GC GENERAL CONTRACTOR 0 7 8 0 SPACE LED CURTAIN WALL 1500 20 2 7 8 0 SPACE CV ��/ SHADING ON FIXTURE INDICATES EMERG.BATTERY BACKUP GND -GROUND 0 9 10 0 SPACE 1500 9 10 0 SPACE 03 8 GFI -GROUNDFAULTINTERRUPTER II I I FLUORESCENT STRIP FIXTURE 0 11 12 0 SPACE LED CURTAIN WALL 1500 20 2 11 12 0 SPACE _ > o 0 co MC -MECHANICAL CONTRACTOR 1 I .6. .6, I TRACK LIGHT AS NOTED OR SCHEDULED NIC -NOT IN CONTRACT SPACE 0 13 14 3 200 18050 STAGE LEFT 200A#1 " 1500 13 14 0 SPACE a) .tn p co NL -NIGHT LIGHT SPACE 0 15 16 18050 " LED CURTAIN WALL 1500 20 2 15 16 0 SPACE C ti WALL WASHER C O , NTS -NOT TO SCALE SPACE 0 17 18 18050 " 1500 17 18 0 SPACE O O)O o 0 0 . 0 POLE-MOUNTED FIXTURE PC -PLUMBING CONTRACTOR U ti REF -REFERENCE SPACE 0 19 20 0 LED CURTAIN WALL 1500 20 2 19 20 0 SPACE 0 N a rn 0 POST(BOLLARD)FIXTURE - 0 -0 c E UG UNDERGROUND SPACE 0 21 22 0 " 1500 21 22 0 SPACE N O X O N_ STEP LIGHT UNO UNLESS NOTED OTHERWISE SPACE 0 23 24 0 LED CURTAIN WALL 1500 20 2 23 24 0 SPACE C c- Q co 0 UTP -UNSHIELDED TWISTED PAIR ® CEILING OR WALL MOUNTED EXIT LIGHT . 96) '‘.4. J WP -WEATHER PROOF STAGE RIGHT 200A#1 18050 200 3 25 26 3 100 9000 SOUND BOARD 1500 25 26 0 SPACE - L .co EMERGENCY BATTERY LIGHTS XFMR -TRANSFORMER 18050 27 28 9000 LED CURTAIN WALL 1500 20 2 27 28 0 SPACE N , 0 , 0 > DUPLEX RECEPTACLE @ 18"UNLESS NOTED +18" MOUNTING HEIGHT TO CENTERLINE CV OF DEVICE AFF OR AFG II 18050 29 30 9000 1500 29 30 0 SPACE - °6 2 w Loco) N d=• DOUBLE DUPLEX RECEPTACLE @ 18"UNLESS NOTED FIRE ALARM SYSTEM II 0 31 32 3 200 9127 PANEL CATWALKco SPACE 0 31 32 0 SPACE 0) L Cl) ap co. FLUSH FLOOR DUPLEX RECEPTACLE II 0 33 34 9127 " SPACE 0 33 34 0 SPACE CL W ti -j A SPECIAL OUTLET AS NOTED .1 FACP FIRE ALARM CONTROL PANEL II0 35 36 9127 " SPACE 0 35 36 0 SPACE w_ 2 J 06 O Ca DUPLEX RECEPTACLE HALF-SWITCHED @ 18"UNLESS NOTED ma FIRE ALARM ANNUNCIATOR PANEL 0 37 38 3 100 15722 PANEL TP SPACE 0 37 38 0 SPACE CU w -c CO O POP-UP RECEPTACLE Q FIRE ALARM PULL STATION 0 39 40 15722 " SPACE 0 39 40 0 SPACE i -•3 ® TELE-POWER POLE ❑4 ALARM HORN OR SPEAKER 0 41 42 15722 " SPACE 0 41 42 0 SPACE U v v = o I MULTI-OUTLET PLUG STRIP Imo; COMBINATION HORN/STROBE OR SPEAKER/STROBE a) C � Q Q JQ JQ--I JUNCTION BOX IN FLOOR,CEILING OR IN WALL •H THERMAL HEAT DETECTOR LOAD CALCULATION SUMMARY LOAD CALCULATION SUMMARY PROVIDE PANEL SURGE SUPPRESSION OPTION FOR OWNER TO REVIEW N O D a- TD 8 V COMPUTER/TELEPHONE OUTLET IN FLOOR OR WALL •I SMOKE/IONIZATION DETECTOR (,� 2 < c'761- 1-÷- 1— I-- - TELEVISION OUTLET •P PHOTOELECTRIC SMOKE DETECTOR CALCULATED POWER FACTOR: CALCULATED POWER FACTOR: i o 1.00 0.96 Q o rit TELEPHONE BACKBOARD •H/P HEAT/PHOTOELECTRIC SMOKE DETECTOR CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING Sl ER DUCT DETECTOR LIGHTING/CONTINUOUS 18000 50 22500 62 LIGHTING/CONTINUOUS 18000 50 22500 62 CIRCUIT HOMERUN FQ SPRINKLER SYSTEM FLOW SWITCH RECEPTACLES 238775 661 124388 345 RECEPTACLES 2160 6 2160 6 — — — CONDUIT RUN BELOW FLOOR OR GRADE M- SPRINKLER SYSTEM TAMPER SWITCH MECHANICAL 7220 24 9025 29 MECHANICAL 7220 24 9025 29 '•+.,'QO . EG!',,,, ] CONDUIT STUB-UP-CAP&MARK ID �`S STROBE KITCHEN 0 0 0 0 KITCHEN 0 0 0 0 , N Sjp, LIGHT SWITCH AT 46"UNLESS NOTED QD SMOKE/FIRE DAMPER CONNECTION TOTAL 263995 735 155913 436 TOTAL 27380 79 33685 98 Q d h;, c<`,101SUBSCRIPTS: : 0 2=2-POLE SWITCH REMOTE INDICATOR LIGHT ` lmiliji a 3=3- WAY SWITCH SECURITY SYSTEM - =r !`.; 4=4-WAY SWITCH • • M=MOTION-OPERATED SWITCH DC CONTACT DOOR SWITCH IN JAMB OR HINGE -J + K=KEY-OPERATED SWITCH O C [, c" TO=THERMAL OVERLOAD SWITCH � INTRUSION MOTION DETECTOR AS SPECIFIED,CORRIDOR/ROOM P=SWITCH WITH PILOT LIGHT C OR R �'0, \.41 Z O a`' • ON1\- �K KEY-OPERATED ACCESS SWITCH •" `�� ❑D DIMMER SWITCH W/WATTAGE •• Sf • Q PUSHBUTTON CONTROL STATION >11 SURVEILLANCE CAMERA ,,."�' ,,,,,, PC PHOTOELECTRIC CELL TS TIME SWITCH DISTRIBUTION EQUIPMENT SYMBOLS QT THERMOSTAT AT 60"UNLESS NOTED DISCONNECT SWITCH eDIVISION 15 EQUIPMENT —,1-N— FUSES I I FOOD SERVICE EQUIPMENT CIRCUIT BREAKER COMMUNICATION SYSTEM \ AJ CURRENT TRANSFORMER TRANSFORMER Ill ® 0-I SPEAKER IN CEILING OR WALL RD METER PANEL PANEL 11 E-1 VOLUME CONTROL AT 60"UNLESS NOTED CATWALK TP ® MAGNETIC MOTOR STARTER OM OM I MICROPHONE OUTLET IN FLOOR BOX OR WALL EF, DISCONNECT SWITCH i_ __ OC -I CALL-IN SWITCH ' PANELBOARD OR LOAD CENTER,FLUSH OR SURFACE MOUNTED F— © PROGRAM BELL < H I SWITCHBOARD,MOTOR CONTROL CENTER OR DISTRIBUTION BOARD Q INTERCOM NEW WORK IS CLOUDED LITRANSFORMERO. < QQ CLOCK SII, GROUND �A AMPLIFIER E CIRCUIT BREAKER 12 "..' Ill QM MOTOR OUTLET 4,676 AIC OE AUTOMATIC TRANSFER SWITCH 0 (4#3/0 CU, 1 #4 AL G)2"C F' w E 0 L.L ELECTRICAL SPECIFICATIONS PANEL O P 2'-S 0 0 General Requirements 10P 11 v 600/3 CL 1. SCOPE: Furnish all materials and labor required to execute this work C 2 J as indicated on drawing and as specified, as necessary to complete the contract. Electrical work shall include, but not limited to, these major 8,500 AIC items: A. Complete wiring system for new lighting and power as shown, 2[(4#500 MCM AL, 1 #250 MCM ALG)3"C] r' including new panelboards, new conduits, new wires, new wiring 0 devices, new control devices, etc.for a complete lighting and and power system. a. Complete feeder(s) installation as required for new and/or 150 208V DELTA TO electrical apparatus as shown on single line diagram and 120/208V 3P 4W F O drawings. 2. Complete provision, installation and connection of lighting fixtures, < LL exit signs and lamps as specified and as shown on drawings. 2[(4#500 MCM AL, 1 #250 MCM ALG)3"C] r' 3. Provide grounding and bonding Facilities. 0 4. Test of entire system and work. 5. Operating, Maintenance and identification instructions manuals, if any. 6. PERMITS AND FEES: Obtain and pay for all necessary permits, inspec- AEC PROJECT #: 18018 tions, examinations and fees or charges necessary for execution and METER#910392 HIGHEST DEMAND completion of electrical work. CONCESSION UNIDENTIFIED DIMMING PANEL PANEL HEATING COMPANY LIGHTING AND EAST LIGHTING AND L1A WEST SERVICE 156KW OR 432 PANEL MP1 MP2 PANEL L1D SWITCH POWER L1C SERVICE POWER L1B BUILDING DATE: ISSUE: 7. REGULATIONS AND CODES: AMPS FOR LTG BLD 05/27/15 PERMIT A. Applicable codes: National Electric Code(2008) — — — — — — 1— — — — — — l'‘ t — — — — — — — —Conform to the prevailing edition and amendments thereto of the Local Electrical Codes, pertinent NFPA publications600/3 200/3 150/3 600/3 200/3 200/3 400/3 400/3 0/3 100/3 100/3 100/3 100/3 and to the requirements of Federal, State or other City agencies (2)200A having jurisdiction. 1,000 AIC 31,738 AIC(I I ^ SPACES I 8. CONDUIT AND WIRE: 7[(4#500 MCM AL)3"C]I U1/4) I 2000/3 I A. CONDUCTOR SIZES AND TYPES: For sizes#1/0 AWG and larger, use copper THW or aluminum XHHW. For sizes#1 AWG and smaller, use only UTILITY Drawn By: Checked By: copper wire with 600V insulation, types TW, THHN, or THW-stranded in — — — — — — — — — — — — — — — — — — — — — — — — SOH AEC sizes#8 and larger, solid in sizes#10 nd smaller. Control wiring shall be#14, TRANSFORMER MAIN DISTRIBUTION CENTER "MDC" stranded. Provide a minimum#8 wireper EC drawings. PAD MOUNTED 2000A, 20/2osv, 3P, 4W ELECTRICAL NEMA 3R 42kAIC ALL INFORMATION SHOWN IS BY SITE ONE-LINE OBSERVATION. IF THE CONTRACTOR DISCOVERS ANY DEVIATION FROM THE & PANEL INFORMATION SHOWN, PLEASE ALERT THE PARTIAL ELECTRICAL ONE-LINE DIAGRAM ELECTRICAL ENGINEER. NO SCALE SCHEDULE NOTE: PROVIDE SHORT CIRCUIT BRACING TO MEET FAULT CURRENT LEVELS NOTED ON ONE-LINE AS "X AFC", WHERE X IS IN AMPS. SERIES RATED CIRCUIT BREAKER COMBINATIONS ACCEPTABLE; SUBMIT MANUFACTURER'S SERIES RATINGS WITH SHOP DRAWING REVIEW. E1 . O 1 of 1 ®COPYRIGHT 2014 ARCHITECTURAL ENGINEERING CONSULTANTS, INC.=