Loading...
HomeMy WebLinkAboutDRB18-0159_approved plans_1525361887.pdf „.,,,,,,:;,110,„ Z' c Ote.l.g., elt 174 DRB APPROVED Schacht Residence 5/3/2018 12:00 00 AM 1800 SIERRATRAIL VAIL COLORADO CURRENT ARCHITECTS AND ASSOCIATES PO BOX 5293 GENERAL NOTES : PROJECT LOCATION : PROJECT SUMMARY : DRAWING INDEX . VAIL COLORADO 81657 970 331.6345 1. DO NOT SCALE DRAWINGS. � � Y�.- ,� r � - , � i� � � �. ” '� �• 0 � f "i"�� � www.currentarchitects com ,. — , • A po' F -441 ', ,d ' °` �rk4 , CODE: ARCHITECTURAL 2. VERIFYALL DIMENSIONS, CONDITIONS,AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY - ,_' ", :�� ;- > '� ' al s �, �- '- . i i, ��" q 2009 INTERNATIONAL RESIDENTIAL CODE A 000 COVER SHEET .0, 3 ,-,-.. . . ',, -" �. FCO/O . c f-• e Lei''^ .� x!.' ,.� ,� - O WORK OR ORDERING ANY MATERIALS. NOTIFYARCHITECTOF ANY CONE LICTSOR �; F `, ;; n ,7'; �k ' A 001 GRFAANALYSIS , DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. ' ` •" , z, - AC '•j+• i ZONING: �-9 �� W. MICHAEL ' � g; - . Y 4' A 100 EXISTING LOWER LEVEL PLAN Q • •F AA 'S? �' '` � - � ' �%r " , PLANNED URBAN DEVELOPMENTcr) CURRENT o 3. AREAS OF CONFLICTSOR DISCREPANCIES MUST BE FULLYRESOLVED WITH WRITTEN $ q T' '- ��, " qrr tom _ , A 101 EXISTING AND PROPOSED MAIN LEVEL PLAN APPROVAL FROMTHEARCHITECTSBEFORECONSTRUCTIONCONTINUES IN THESE '1/4 �� = * 1x� i �.... tf` - ' - ! �" ..�w ~•--,,f,„1.3 ,-.1,,,. r ��' vk ' K ` '� - -�. OCCUPANCY CLASSIF KATION: A 103 EXISTING AND PROPOSED UPPER LEVEL PLAN r {— PARTICULAR AREAS. ; , ., 7, ! 41 r `. '• t ie F, h -' --,;e1.$,-..g2 _ J , ` ,.0 ,., • ,. "'�' � -' ' ;; -rr- ,' ' • TYPE R DIV. 3 (. 402525 r STRUCTURAL 4. PLAN DIMENSIONS ARE TO FACEOF STUD,CENTERLINE OF STEEL,TIMBER,STUD r °® s •.g t " V'..-,..3. --... -:(-2-, .. ? �' � 3 x'` " . /1/. -- - � COLUMNS, OR FACEOF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION % 0.-: 4. • , =• . . _ ei-t';,.; J h : , i CONSTRUCTION CLASSIFICATION: Si F RAMINGPLANS FD ARG DIMENSIONS ARE TO TOP OF CONCRETE,TOP OF PLYWOOD,OR TOP OF WALL PLATES OR ,� 4 ''.,..:V j'3,. 4'`, --,3c .' i. 'i or • r r.4 TYPE V-B S2 DETAILS BEAMS UNLESS OTHERWISE NOTED. �,;ir /♦'`i ' ' ; • 'N.; I flit °'-., -po t ., - .i A. - •"R r , s` •- `/` ' - . 'rE�d-,— _ • r Tsai- 5. PROVIDEALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE FF r `� r kr.--� ? _ ,/• /'' e+i } f BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED F IXTURES,TOILETS,TOILET ` .. .6/ �" 1 lr ,,' ACCESSORIES,CABINETRY, COUNTERTOPS,SHELVES,CLOSET RODS AND FALSEBEAMS. a: s '� - i" '``�` 4.),-.4:',A4` 6. REF ERTO F LOORPLANS F OR DOOR LOCATIONS. REF ERTO DOOR SCHEDULE F OR DOOR e• e ";' r +� TYPES. { ♦ t G' `` _r:_. - r i' 1 K•; •!' •LTi' .A' ', - VE.Ihflpnr-F..• / .e ''%.. r 7. REF ERTO FLOORPLANS FORWINDOW LOCATIONS. REF ERTO WINDOW SCHEDULE FOR , ; .. „ '' ; jt WINDOW TYPES. _, may► "R+.i i, - ___ t..— • 8. COORDINATE ALL ELECTRICAL AND MECHANICAL F IXTURESTO F IT WITHIN CEILING FLOOR '� F i' e- t AND WALL SPACES. VERIFYWITHARCHITECT WHEN DIVERTING FROMDRAWINGS. .' 't { - - �r� • Ili' �,-? 4•' i' 7r� a Se0.a a A7;� y' • 1 :a ' r FSI y Cr 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR ' + '` , i., ,< F OR CONSTRUCTION OF ANY ASPECT OF THE PROJECT,THEY SHALL IMMEDIATELY NOTIFY � _> :; lit- ilf;• THE ARCHITECT. FAILURETO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. 10. THE GENERAL CONTRACTORSHALL BE RESPONSIBLE F OR SATISF YINGALL APPLICABLE 1800 SIERRA TRAIL /\ CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. COMPLIANCE WITH ALL VAIL, COLORADO Mr CURRENT CODES IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT 81657 WORK THAT DOES NOT CONE ORMTO ALL RELEVANT CODES INCLUDING THE INTERNATIONAL BUILDING CODE AND ALL LOCAL AND REGIONAL CODES. 11. THE GENERAL CONTRACTORAND SUBCONTRACTORS SHALL F IELDCOORDINATE AND OBTAIN APPROVALS F ROMTHE ARCHITECT/ENGINEER BEF OREANY CUTTING, NOTCHING, OR DRILLING OF ANY CAST-IN-PLACE CONCRETE,STRUCTURAL F RAMING,OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AF F ECTTHE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. PROJECT TEAM W 12. THE GENERAL CONTRACTORSHALL VERIFYALL EXISTING GRADES AND SCALE OUT THE ' ` BUILDING F OOTPRINTF OR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY V SITE WORK. ARCHITECT: 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS,ROOF& CURRENT ARCHITECTS W DECK SURFACESMUST BE MAINTAINED REASONABLY F REEOF ICE &SNOW TO ENSURE Q MINIMAL PROBLEMS WITH THESE SURFACES. PO BOX 9253 VAIL, CO 81657 �— 14. SUBSTITUTIONS OF"EQUAL"PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WWW.CURRENTARCHITECTS.COM V J WRITTEN APPROVAL. PHONE: 970-331-6345 W 15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTACT: MICHAEL CURRENT CONTRACTORAND EACH SUBCONTRACTORPROVIDEALL LABOR,MATERIALS TRANSPORTATION, SUPPLIES,EQUIPMENT, ETC.TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. STRUCTURAL ENGINEER: KERRIGAN ENGINEERING I— J 16. ALL CONSTRUCTION IS TO F IT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS. NOTIFYARCHITECTIMMEDIATELY OFANY PO BOX 3032 T O Q< 0 DISCREPANCIES. EAGLE, CO 81631 U I– Q f 17. THE GENERAL CONTRACTORSHALL F IELDVERIFYTHE LOCATIONS OF ALL EXISTING PHONE: 970-331-4733 < Ct 0 UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION _I CONTACT: SEAN KERRIGAN IMPACTS TO THE SITE. T I L.I 0 18. THE GENERAL CONTRACTORSHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE GENERAL CONTRACTOR: U o J ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. v,' ^ 0 j ALL AREAS OF DISTURBANCE SHALL BE RE VEGETATED TO BLEND WITH THE NON DISTURBED LMS CONSTRUCTION LANDSCAPE. PO BOX 3497 19. THE SOILS REPORT IS AVAILABLE F ROMOWNER'S SOILS ENGINEER. VAIL, CO 81657 PHONE: 970-393-2163 PROJECT : 17-SCH 20. GENERAL CONTRACTOR SHALL VERIFYALL SITE DEVELOPMENT WITH LANDSCAPE CONTACT: LEE SEDOTA CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS DRAWN B Y : - FORLAYOUT; IN CASE OF ANY DISCREPANCIES VERIFYWITH ARCHITECT. DATE : 04.30.2018 REVISIONS : COVER SHEET lei OF bit. ApApiiiiiiiiiiiiiI 1 0 c DRB APPROVED 5/3/2018 12:00 00 AM p i CURRENT i 4I ARCHITECTS riiiir LiIP .1 AND ASSOCIATES / PO BOX 5293 /I VAIL,COLORADO 81657 A 970.331.6345 vv .crrenarchitects.com •uu'pip#J MICHAAW (� CURRENT Q %r /Pi' L A 0 402525 MAIN LEVEL AREA: .S.\ ,, ARG 2 070sf ir A Will Orr IF _ GRFA ANALYSIS: I ZONING: TWO-FAMILY P/S ..)1 LOT AREA: 10,634sf / SITE COVERAGE ALLOWED: 2,127sf ` /0/ SITE COVERAGE EXISTING: 2,080sf . Ii � GRFA ALLOWED: 4,841sf I , GRFA EXISTING AND PROPOSED: N.,', i L ,e,� LOWER LEVEL: 434sf MAIN LEVEL: 2,071sf UPPER LEVEL: 1,009sf TOTAL: 3,514sf *LOWER LEVEL INCLUDES 600sf GARAGE CREDIT,AND CRAWLSPACE OVER 5' IN HEIGHT, BUT DOES NOT INCLUDE BELOW GRADE WALL DEDUCTION. MAIN LEVEL INCLUDES CRAWL/STORAGE AREA SPACES OVER 5' IN HEIGHT. (2)MAIN LEVEL AREA PLAN 1/8"= 1'-0" ILI 0 z W 0 rr V r - ---\4r— Ar (/) ; , I 1 ', L Li \ ,, r 'd r►A Q O QFY U < D: o ct J J L r--i LLJ 0 ji A A I r LEVEL V c) J AAREA: 1,009sL /: I /1 PROJECT : 17-SCH DRAWN BY : - A W L WER LEVE AREA: 1 034sf DATE : 04.30.2018 Ai#... 1 REVISIONS : \ 1 I, I I 1 I SITE PLANS UPPER LEVEL AREA PLAN LOWER LEVEL AREA PLAN 1/8"= 1'-0" 1/8"= 1,-0" A001 Itt(1 CIF 1°4 iii; '141 ,1111 VA S C g 31120D'el' DRB APPROVED 5/3/2018 12:00 00 AM / 7'-0" 37'-92" 7._22.. / **EXISTING CONDITIONS DIMENSIONS FOR REFERENCE ONLY CURRENT r _ \ ARCHITECTS AND ASSOCIATES PO BOX 5293 VAIL,COLORADO 81 657 970 331.6345 w}nrw.currentarch itects.corn t NI 4,0f COLO/5) it,...'Sr W. MICHAEL -1Q (r) CUR ENT 0 i ~ L FOUNDATION FOOTER/STEP TYP. J 0c<,02525 r 1 D FOUNDATION �1- PAD. N r 1 I 1 FOUNDATION r PAD. L 1 1 1 L J r I- J L 1 I t 1- r 11 1 F L 1 FOUNDATION FOOTER/STEP TYP. 1 SIN Eo L J \ CRAWL 205 SO FT.OVER 5' i� w / . ` 0 Z UP w 0 / J ,, // w 0 \ / \ / J � �/ OI- < N �/ \ / LLO _ � � = w O U1 U vo - C� GARAGE PROJECT : 17-SCH DRAWN BY : - DATE : 04.30.2018 REVISIONS : / 33'-0" 23'-0" J. FLOOR PLANS 0 EXISTING LOWER LEVEL PLAN A 1 0 0 1/4"=1'-0" 0 S C eC 417 % 53P5 j 1120D 1°1' DRB APPROVED 5/3/2018 12:00 00 AM CURRENT ARCHITECTS AND ASSOCIATES PO BOX 5293 VAIL,COLORADO 81657 970.331.6345 www.currentarch itects.com / 13.-34" / 13' 6Z" / 8'-6" / OF COLO V - W. MICHAEL� /.... . 1 (/) CUR ENT O i /- 3T'3Z' 'CV1402525 NEW BATH FOR BEDROOM 2. INCLUDES / 3'-0' 4'-0" /1' 6" 1'-6" 3'-0" / + / 2'-6" /1'-6"/1'-6"/ 3'-0" / S DEMO OF EXISTING FLOOR& STAIR FD ARG ` FRAMING TO EXTEND EXISTING LANDING, VERIFY LOC. OF CLOSET ABOVE,ALIGN WEST WALL Ci!DEXISTING STEP AND ELEC PANEL TO REMAINJ • e —0— ,:\ co co NEW BATH IN EXISTING CRAWL,ONE STEP AT ENTRY IF REQ'D. En in (-7-,,,,,-0, t 7-;cc)c (N)30x806x6—\ 1 \ i30x66 / 3'-6" 7//4, 2'-4" / 6'-84„ / 2'-4" /1'-7"/ 62� // - — POSSIBLE ADDITIONAL STORAGE LOCATION UNDER STAIRS FOR BEDROOM BEDROOM 4? 2 ---1— / REPLACE EXISTING NON-EGRESS WINDOW WITH NEW 34"x60"WINDOW, NEW HEADER NOT REQ'D, LOWER SILL TO±34"AFF k \ 3Z = TWO STEPS AT ENTRY TO BEDRM TO REMAIN / 34 �/ ±2'-52" 0 UP wN.M ivNEW CLOSET M_ Rico M +1 UP 7 svI w 0 = W _ a DN w I I II C I I �- J 0I- < • Quo = w O E5 0 * * Uo _ 1 • ., 'I. PROJECT : 17-SCH 4 - i_Lr— * DRAWN BY : - .1 C IV DATE : 04.30.2018 REVISIONS : FLOOR PLANS A1010 PROPOSED MAIN LEVEL PLAN 0 1/4"=1'-0" Vecz S C '-'11213D IP DRB APPROVED 5/3/2018 12:00 00 AM CURRENT ARCHITECTS AND ASSOCIATES PO BOX 5293 VAIL,COLORADO 81 657 970 331.6345 w}nrw.currentarch itects.corn 4,0f coLO'Q it,...'Sr W. MICHAEL -1Q NEW BATH FOR BEDROOM 3. RAISE FLOOR UP TO (/) CUR ENT 0 LEVEL WITH EXISTING BEDROOM.NEW DOOR AND / ±9'-112" / DEMO OF EXISTING STAIRS TO MIDLEVEL i ~ C� 402525 ��u I I �SFD ARG ` 30 (N)28x80 0 0 w o x -� w in /— / BEDROOM ® Ccil) , / / 3 / 7))//' `//////////, /////// 0 / / 2'-1O' 1. 2 8 7.-8i" 'IN -� HIGH BATH BATHROOM 2 MASTER in STORAGE BELOW BATH \ ' 1 , r (STORAGE ABOVE) 0 N., B— C{ N ) ( BEDROOM 2 — BELOW MASTER CLO DN <- l N _ ILI 0 MASTER z W a ILI = g 8 OI < < aO = w O U vow U) 053 > PROJECT : 17-SCH DRAWN BY : - DATE : 04.30.2018 REVISIONS : FLOOR PLANS A1020 PROPOSED UPPER LEVEL PLAN 0 1/4"=1'-0"