Loading...
HomeMy WebLinkAboutA000FOR CONSTRUCTION Project number Date Drawn by 5/27/2016 11:02:31 AM A000 COVER SHEET MAT-15 1552 MATTERHORN CIRCLE VAIL, COLORADO MATTERHORN INN CONDOMINIUMS 05.26.2016 wmc 05.26.2016 MATTERHORN INN CONDOMINIUMS GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. 2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR AREAS. 4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED. 5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS. 6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR TYPES. 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS. 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL RESIDENTIAL CODE. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN UBC AND ALL LOCAL AND REGIONAL CODES. 11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL PROBLEMS WITH THESE SURFACES. 14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN APPROVAL. 15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. 16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO THE SITE. 18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE. 19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER. 20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT. 1552 MATTERHORN CIRCLE, VAIL, COLORADO DRAWING INDEX CIVIL C001 TOPOGRAPHIC SURVEY ARCHITECTURAL: A001 SITE AND LANDSCAPE PLAN A002 GRFA AREA PLAN A100 FOUNDATION/CRAWLSPACE PLAN A101 EXISTING MAIN LEVEL FLOOR PLAN A102 PROPOSED MAIN LEVEL FLOOR PLAN A103 LOFT FLOOR PLAN A104 ROOF PLAN A111 REFLECTED CEILING PLAN AND ELEC LOAD CALCS A201 EXISTING ELEVATIONS A202 PROPOSED ELEVATIONS A301 BUILDING AND WALL SECTIONS A601 WINDOW AND DOOR SCHEDULES AND DETAILS A900 EXISTING PERSPECTIVE A901 PROPOSED PERSPECTIVES STRUCTURAL: S-0 GENERAL NOTES S-1 FOUNDATION PLAN S-2 MAIN LEVEL FRAMING S-3 LOFT LEVEL FRAMING PLAN S-4 ROOF FRAMING PLAN S-5 STRUCTURAL DETAILS S-6 STRUCTURAL DETAILS S-7 STRUCTURAL DETAILS MECHANICAL: M1.0 GAS PIPING DIAGRAM AND VENTING PLAN PROJECT SUMMARY: CODE: IBC 2012 ZONING: TWO-FAMILY PRIMARY/SECONDARY (NO ZONING WHEN ORIGINALLY CONSTRUCTED IN 1972) OCCUPANCY CLASSIFICATION: TYPE R DIV. 3 CONSTRUCTION TYPE: TYPE V-B ONE STORY, WOOD FRAMED, 11 UNIT BUILDING WITH 2-HOUR PARTY WALL SEPARATION, 1-HOUR EXTERIOR WALLS AND ROOF ASSEMBLIES, FULLY SPRINKLED WITH MONITORED ALARM SYSTEM PROJECT TEAM: ARCHITECT: CURRENT ARCHITECTS PO BOX 5293 VAIL, CO 81657 PH: 970.331.6345 CONTACT: MICHAEL CURRENT STRUCTRUAL ENGINEER: KERRIGAN ENGINEERING PO BOX 3032 EAGLE, CO 81631 PH: 970.331.4733 CONTACT: SEAN KERRIGAN SURVEYOR: KIPP LAND SURVEYING PO BOX 3154 EAGLE, CO 81631 PH: 970.390.9540 CONTACT: RANDY KIPP GENERAL CONTRACTOR: ROCKY MOUNTAIN CONSTRUCTION GROUP 120 WILLOW BRIDGE RD, STE. 7 VAIL, CO 81657 970-476-4458 CONTACT: STAN BELVIN VICINITY MAP: No. Description Date 06/15/16