HomeMy WebLinkAboutA100A202
2
A202 4
A202
3
A202
1
1
2
3
A B C D E F G H I J K L
1
A301
VFY
151' - 6"
VFY
32' - 4"
4' - 10" INFILL EXISTING CRAWL SPACE ACCESS
BACK-FILL UNDER EXTG ENTRY WALKWAY, NEW THICKENED EDGE CONC WALK ABV
4' - 6 1/4" 0' - 6"
REMOVE ALL DEBRIS - WIRING, PIPING,
INSULATION, LUMBER, ETC. FROM EXISTING
CRAWLSPACE LEVEL REMAINING SOIL
CRAWL SPACE ACCESS HATCHES, TYP.
EXPOSED EARTH TO BE
COVERED WITH A CONTINUOUS
CLASS I VAPOR RETARDER.
JOINTS SHALL OVERLAP BY 6"
MIN, AND SHALL BE SEALED OR
TAPED. THE EDGES SHALL
EXTEND UP STEM AND PARTY
WALLS 12" MIN, AND SHALL BE
ATTACHED AND SEALED TO THE
STEM AND PARTY WALLS., TYP.
3-4" DIA. PERF
PIPE
CONNECTED TO
PVC T-FITTING
SUPPORT FOR
PVC VENT PIPE
THROUGH MECH
CLOSET, SEE
DETAIL, TYP. 11
UNITS
4
A301
FOUNDATION WALL
INSULATION:
EXTERIOR R-20 DRAIN
AND DRY BOARD,
CONTINOUS FROM TOP
OF FNDN WALL TO T.O.
FTG, TYP.
RETURN R-20 RIGID
INSULATION 24" INSIDE
PERIMETER OF FNDN
WALL, TYP.
FIRE SPRINKLER
RISER ROOM
ABOVE, R-38 MIN
INSULATION IN
CANTELEAVERED
FLR ASSEMBLY
FOR CONSTRUCTION
Project number
Date
Drawn by
5/27/2016
11:31:47 AM
A100
CRAWLSPACE PLAN
MAT-15
1552
MATTERHORN
CIRCLE
VAIL,
COLORADO
MATTERHORN INN
CONDOMINIUMS
05.26.2016
WMC
3/16" = 1'-0"
1
CRAWL SPACE
No. Description Date
06/15/16