Loading...
HomeMy WebLinkAboutS-6 Details_Dumpster Enclosure10'-0" 8" 8'-8" 8" 15'-0" 8" 6'-8" 2'-10" 2'-10" 1'-4" 8" 8" 5'-112" 8'-612" 8" C -- A -- B -- 12" THICKENED EDGE 6" DIA CONC. FILLED STEEL PIPE BOLLARD TYP. OF (3) 6" SLAB ON GRADE W/ #4 BARS @ 12" o.c. E.W. 8x8 DF No. 2 COL. UP, TYP. 8x8 DF No. 2 COL. UP, TYP. D -- ROOF FRAMING PLAN SLAB FOUNDATION PLAN 1 4 " DIA TENSION WIRE OR ROD X-BRACE, TYPICAL AT BOTH SIDE WALLS AND BACK WALL SCALE: 3 4"=1'-0 A -- SCALE: 3 4"=1'-0 B -- C -- SCALE: 3 4"=1'-0 D -- SCALE: 3 4"=1'-0 PLAN NOTES: 1. ROOF SHEATHING IS 1/2" EXTERIOR EXPOSURE RATED AND NAILED TO ROOF MEMBERS AT 6" O.C. AROUND PERIMETER OF PANELS AND 12" IN FIELD OF PANELS. ORIENT LONG DIRECTION OF PANEL ACROSS RAFTERS AND STAGGER JOINTS. 2. RAFTERS ARE: 2X8 DOUGLAS FIR No. 2 DRESSED LUMBER, SPACED AT 12" o.c., TYPICAL, UNLESS NOTED OTHERWISE. ALTERNATIVES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE REVIEWED BY THE ENGINEER OF RECORD. 3. PERIMETER SIDING SHALL BE 2x6 WOOD MEMBERS (WESTERN CEDAR, WESTER WOODS WITH APPEARANCE GRADE B &BTR SELECT WITH ALLOWABLE BENDING STRESS Fb OF 700psi OR GREATER), PROFILE SIDING MEMBERS AS SHIPLAPPED OR T&G AS APPROVED BY ARCHITECT. FASTENED AT ALL SUPPORTING COLUMNS WITH (3) No. 8 x 3" SCREWS. PRE-DRILL SIDING MEMBER AS REQUIRED TO PREVENT SPLITTING. 4. RE: ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF ROUGH OPENINGS IN ENCLOSURE 4x6 PLATE AT TOP OF SIDING BOTH SIDE WALLS AND BACK WALL SIMPSON HL55PC HEAVY GUSSET ANGLE 1 4 " DIA TENSION WIRE OR ROD X-BRACE, TYPICAL AT BOTH SIDE WALLS AND BACK WALL ENCLOSURE SECTION 15031 S-6 DUMPSTER ENCLOSURE 0 10.15.15 ISSUED FOR PERMIT TOWN OF VAIL, CO MATTERHORN INN NO. ISSUE PROJECT: JOB NO. SHEET NO. JURISDICTION: 10.16.15 11/04/15