HomeMy WebLinkAboutA18-0006_LIPNICK DATA SHEETS_1520633850.pdf Honeywell VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS iii4 , , The VISTA-128BPE is a powerful member of the Honeywell The VISTA-128BP and VISTA-128BPE(VISTA-128BP Rev.4) family of commercial alarm panels, integrating burglary, COW are Listed for residential burglary, residential fire and commercial and access control functions. Many features are available that burglary applications(see agency listings in this document for extend the applications of the VISTA-128BP while simplifying more details).They are compatible with a wide range of end-user operation. AlarmNet communications products for alarm reporting, uploading/downloading and remote services. FEATURES Standard features •Zone 7 may be used for keyswitch •Scheduled check-in (VISTA-128BP and VISTA-128BPE): arming/disarming •Arm stay by group • Provides nine style-B hardwired zones • Supports V-Plex®addressable • Supports up to 119 additional zones VistaKey access control (up to eight Enhanced features using a built-in polling (V-Plex, doors and 250 cards) (VISTA-128BPE only): multiplex) loop interface • Easily programmed and maintained • Carbon monoxide(CO)zone • Supports up to 127 wireless zones by Compass Windows-based type support using up to two 5800 series wireless downloader • Expanded RS-232 capability receivers(fewer if using hardwire • Supports up to 96 programmable for third party interface and and/or polling loop zones) outputs automation • Provides one power-limited bell circuit • Programmable to meet SIA false • Internet upload/download over delivering 1.7Amp(max)at 12Vdc alarm prevention specifications. AlarmNet GSM, iGSM and IP • Provides the ability to control eight To meet UL approval for ANSI/SIA communicators over the panel's separate partitions independently, CP-01-2000 order part number keypad (ECP) bus each functioning as if it had its own VISTA-128SIA • Ringback support for AlarmNet separate control • Panel Linking up to eight panels communicators(confirmation of closing report) •Accommodates 150 user codes with • Supports eight numeric •24-hour dialer test support for seven authority levels pager numbers pp •Accommodates 32 keypad macro • AlarmNet devices YpSupports touchscreen Advanced commands per system User Interface(AUI) • Keeps a log of up to 512 events • Smoke detector reset at keypad •VistaView-100 CCTV support • Quick exit • Supports up to 16 compatible two- • Group bypass wire smoke detectors on zone 1 •Arm faulted • Supports up to 50 latching-type • Event arming glassbreak detectors on zone 8 Honeywell VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ADDITIONAL FEATURES Basic Hardwired Zones •Tamper protection for supervised •A Master partition (9), used strictly to Provides nine style-B hardwired zones transmitters assign keypads for the purpose of with the following characteristics: • Individually assignable to one of viewing the status of all eight partitions • EOLR supervision (optional for zones eight partitions at the same time(master keypads) 2-8)supporting N.O. or N.C. sensors Scheduling •All zones assignable to one of (EOLR supervision required for fire Provides the following scheduling eight partitions and UL burglary installations) capabilities: • Keypads assignable to one of eight • Individuallyassignable to one of partitions or to Master partition 9 to g Open/close schedules(for control of eight partitions arming/disarming and reporting) view system status Polling Loop Expansion • Holiday schedules(allows different •Ability to assign relays to one or all Supports up to 119 additional zones time windows for open/close eight partitions using a built-in polling (V-Plex, multiplex) schedules) •Ability to display fire and/or burglary loopinterface. Current draw can total and panic and/or trouble conditions Timed events(for activation of relays, up to 128mA. Polling loop zones have auto-bypassing and unbypassing, at all other partitions' keypads the following characteristics: auto-arming and disarming, etc.) (selectable option) • Must use V-Plex devices • • Individually programmable account Access schedules(for limiting system number, entry delay and exit delay by • Supervised by control panel access to users by time) partition • Individually assignable to one of • End user output programming mode eight partitions (provides 20 timers for output control) Wireless Expansion Eight Partitions Supports up to 127 wireless zones Provides the ability to control eight using up to two 5800 series wireless separate areas independently, each receivers(fewer if using hardwire functioning as if it had its own separate and/or polling loop zones). control. Partitioning features include: Wireless zones have the following •A Common Lobby partition (1-8), characteristics: which can be programmed to arm • Supervised by control panel for automatically when the last partition check-in signals(except certain that shares the common lobby is non-supervised transmitters) armed, and to disarm when the first partition that shares the common lobby is disarmed 1 V-Plex Loop 1 . i I_ I_ �I - FG1625SN Glassbreak 4208U Eight-zone 5193 4101 SN DT7500SN Expansion Module and 4293SN Adapters Series Smoke Detectors Relay Module V-Plex DUAL TEC 4208EX Eight-zone Motion Sensor V-flex Expander 5881 ECP Bus 1 Wireless Receiver 6160 Console 710 Light Parallel Printer RS-232 s Notification • •I 14204 ii Relay Module 1(:tAppliances Keyswitch al Serial Printer Option 4 4146 titi...... : Phone Line to Central Station at 748 � { Horn JI Alpha Paging —or— or- Module 78471 GSM iGSM NOTE:Please refer to the website(www.honeywell.com/security/hsc)for the latest product information. Honeywell VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ACCESSORIES Auxiliary Devices • 5193SD Wireless Devices • 4204 - Relay Module, four form C • 5193SDT • 5804 -Wireless Key contacts Passive Infrared Detectors • 5804BD- Bidirectional Key • 5881 Series RF Receiver supporting • 998MX • 5804BDV- Bidirectional with voice 5800 wireless detectors • 6160 Alpha Keypad/Annunciator • IS2500SN • 5816 - Door/Window Transmitter • 6220S -System Printer used with • DT7500SN • 5819 -Shock Sensor 4100SM serial module • QUEST2260SN • 5827BD- Bidirectional Keypad •VA8200 - (PLM) Panel Linking Module V-Plex(Addressable)Contacts • 5853 -Glassbreak Detector •VA8201 - (APM)Alpha Paging Module • 4939SN-WH • 5894 -Wireless PIR Motion Sensor Manual Pull Stations • 4944SN-WH • 5890 - Passive Infrared Detection • 5140MPS-1 • 4959SN, 9500SN • 5800PIR-OD -Outdoor • 5140MPS-2 V-Plex Glassbreak Detectors Motion Sensor V-Plex(addressable) Devices • FG1625SN • 5870API Asset Protection Device • 4101 SN Single Relay/zone Module VISTA Interactive Phone Module • COM—Wireless RE Motion Detectors COM—Wireless Detectors • 4190SN Remote Point Module- • 4286 VIP Module • 580000/A Wireless Carbon two zones Optional Communicators Monoxide Detector • 4193SN Two zone Serial Interface •AlarmNet Internet/Intranet • 5800RP-Wireless Repeater Module communicators and digital cellular • 4208EX- Eight zone expander for communicators • 5808W3 Wireless Smoke Detector ULC commercial installations Access Control • 5809 -Wireless Heat Detector • 4208U Loop Expansion Module •VISTAKey V Plex(addressable) Commercial Listed eight zones Access Control Wireless Devices • 4209U Group zoning Module .VISTAKey SK Starter Kit • 5817CB- Commercial UL Burglary, two/four zones Universal Contact Monitoring • 4293SN One zone Serial Interface •VISTAKey-EX Expansion Kit Transmitter* Module • 5869 -Commercial UL Wireless • 4297 Isolation/Extender Module V-Plex CCTV Hold-up Button* (addressable)smoke detectors • Optiflex CCTV module • 5881 ENHC and 5883H Receivers •VSI Short/Overload Isolation Module *When used with 5881 ENHC and/or 5883H receiver. , 1 III 4190SN 4959SN 4944SN IS2500SN 4208U 4193SN Remote Point Module Overhead Door Contact Contact VISTAKey V-Plex V-Plex PIR Eight-zone Serial Interface Module Access Control Motion Sensor Expansion Module - 5808W3 Module 5881ENHC Wireless Glassbreak Detectors Commercial Wireless Receiver Smoke ECP Bus (Max Two) Detector 5800 Series Wireless — 5890 S. MIN 6160 5816I Devices Wireless PIR Console Door/Window - 1 Transmitter / I `� 4209U ing �� 11.1•11114,an GroModuleiliaftik 5869 Commercial UL Supports Up To 4204 Wireless Hold-up 5817CB Universal 16 Conventional __ Relay 4204CF Button Contact Monitoring +1�� Two-Wire Module Supervised Smoke Detectors 41111111/10 NAC Module Transmitter 111111 OF Panel Linking Module Panel Linking Module VISTA-128BP SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS SPECIFICATIONS Agency Listed to the Electrical Main Dialer Following Standards: •Voltage Input: From Honeywell No. • Formats Supported:ADEMCO • UL609 Grade A Local Mercantile 1361 Plug-In Transformer or Contact ID, ADEMCO High Speed, Premises and Mercantile Safe 1361X10 transformer(for X-10 ADEMCO 4+2 Express,ADEMCO and Vault installations)rated 16.5VAC,40 VA Low Speed, Sescoa and Radionics • UL611/UL1610 Grades A, M • Use 1361CN plug-in transformer Low Speed Central Station for Canada • Line Seize: Double Pole • UL365 Grades A,M Police Connect •Alarm Sounder Output: 10VDC- • Ringer Equivalence: 0.7B • UL985 Household Fire 13.8VDC, 1.7 amps max., (UL1023, Cabinet Dimensions UL609 installations); 750mA less aux. • UL1023 Household Burglar Alarm current draw(UL985 installations) 12-1/2" W X 14 1/2" H X 3" D California State Fire Marshall (CSFM) • UL1635 Digital Alarm •Auxiliary Power Output: 9.6VDC- 13.8VDC, 750mA max. For UL Communicator System Units installations,the accessories • CAN/ULC -S303 connected to the output must be UL • CAN/ULC -S304 Listed, and rated to operate in the • CAN/ULC -S545 above voltage range • CAN/ULC -S1023 • Backup Battery: 12VDC, 4AH or 7AH sealed-lead acid.YUASA NP4-12 • For commercial burglary attack proof (12V, 4AH)or NP7-12(12V, 7AH) requirements, use VISTA-ULKT attack recommended proof enclosure • Standby Time: Four hours min. with 750mA aux. load using 7AH battery • Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts).A solid state circuit breaker is used on auxiliary power output to protect against wiring faults(shorts). ORDERING VISTA-128BP Commercial Burglary Alarm Control Panel (UL Listed) VISTA-128BPE Enhanced Commercial Burglary Alarm Control Panel (ETL Listed as VISTA-128BP Rev. 4, UL Pending) VISTA-128SIAE SIA Approved Enhanced Commercial Burglary Alarm Control Panel For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security&Communications 2 Corporate Center Dr. Suite 100 Honeywell P.O. Box 9040 Melville, NY 11747 1.800.467.5875 L ISTA128BPD/D April 2010 www.honeywell.com ©2010 Honeywell International Inc. ****DISARMED**** RERDY TO ARM 6160 -- ALPHA DISPLAY KEYPAD 'NY ****DI{ARMED**** .. I. READY TO ARM 1 WITH DOOR ATTACHED .,. f „ t_. 3 aW s .. Is.. ^-• 7... 8 9 r. WITHOUT DOOR The 6160 Deluxe Keypad is easy to install and simple to The oversized function keys are easily accessed even when use. The attractive white console blends with any decor and the keypad door is closed, and can be programmed for fire, features a contoured, removable door that conceals burglary, personal emergencies and other operations. Colored illuminated soft-touch keys.The 6160 also features a new self-adhesive labels are included. larger and brighter 32-character display with easy-to-read plain-English status messages. FEATURES • Large, easy-to-use keypad •Zones and system events displayed •System functions clearly labeled • Keys continuously backlit for greater in plain English • Functions performed by just entering visibility • No confusing blinking lights security code plus command • Speaker with audible beeps • Four programmable function keys •White with removable door blends to indicate: with any decor -System status - Entry/exit delay -Other alarm situations SPECIFICATIONS Physical Wiring Compatibility • 5-5/16"H x 7-3/8"W x 1-3/16"D • - (Black): Ground • Fully compatible with all (135mm x 190mm x 30mm) VISTA controls. • +(Red): +12 VDC (Aux. Power) Current • D1 (Green): "Data in"to control panel • Standby 40mA • DO(Yellow):"Data out"from •Activated Transmission-160mA control panel ORDERING 6160 Alpha Display Keypad Honeywell Security&Custom Electronics Honeywell Honeywell International Inc. PO Box 9035 COo6o10 Syosset, NY 11791 U6160/D September 2006 www.honeywell.com ©2006 Honeywell International Inc. SYSTEM �$ SENSOR Smoke Detectors with Sounder and Relay Option 7 System Sensor ir sounder and relay smoke detectors apply the guiding principles of installation ease, 3 intelligence,and instant inspection in a series of TM specialty conventional devices. Features Installation ease.Throughout the i3 series,installation is simple •85 dB sounder with its installer-friendly base and plug-in design.The base accommodates a broad range of back box and direct mounting •Form C relay options and provides ample space for pre-wiring the device.To Isolated thermal sensor complete the installation,the i3 detector plugs into its base with a • simple Stop-Drop'N Lock action. •Plug-in design(base included) Intelligence.To reduce the likelihood of nuisance alarms,all •In-line terminals i3 detectors are equipped with both drift compensation and •Flexible mounting options smoothing algorithms.These capabilities minimize both short-and •Stop-Drop'N Lock"attachment to the base long-term causes of nuisance alarms,such as RF interference and dust accumulation.When connected to the 2W-MOD2 loop test/ •Removable cover and chamber maintenance module or an i3 Ready' panel,2-wire i3 detectors can generate a remote maintenance signal when in a maintenance or •Remote maintenance signaling freeze trouble condition.To measure the sensitivity of any i3 detector, •Drift compensation and smoothing algorithms the SENS-RDR displays the reading,in terms of percent-per-foot •Simplified sensitivity measurement obscuration,within seconds. •Dual-color LEDs Instant inspection.i3 has red and green LEDs to simplify local status indication during power-up,standby,alarm,maintenance, and freeze trouble conditions.When in alarm,i3 sounder models generate an 85 dB temporal tone.If connected to the RRS-MOD reversing relay/synchronization module,all i3 sounders on the loop will activate when one detector is in alarm.The RRS-MOD also synchronizes i3 sounder output to ensure a clear audible signal. Agency Listings Should the application call for differentiating between a local and a general alarm,the i3 line offers an isolated thermal model,which (13 ® sO MEA MSFMETA initiates a local alarm when smoke is detected,and a general alarm LISTED APPROVED approved approved cC r. us when the thermal sensor is activated. i�11 3015195 7272-1653:164 372-02-E 2133 3180932 �j�Smoke Detector Specifications Electrical Specifications LED Modes Operating Voltage Nominal:12/24V non-polarized LED Mode Green LED Red LED Condition Duration 2-wire:8.5 V to 35 V Power up Blink every Blink every 10 Initial LED 80 seconds 4-wire:10 V to 35 V 10 seconds seconds status Maximum Ripple Voltage 30%of applied voltage(peak to peak) indication Standby Current 2-wire:50 pA maximum average Normal Blink every 5 off 4-wire:50 pA maximum average (standby) seconds Peak Standby Current 2-wire:100 pA Out of off Blink every 5 4-wire:n/a sensitivity seconds Maximum Alarm Current 2-wire:2WTR-B:130 mA limited by control Freeze off Blink every 10 panel trouble seconds 2WTA-B:130 mA** Alarm off Solid 4-wire:4VVTAB,4WTR 6:35 mA Power-Up Sequence for LED Indication 4WTAR-B,4WITAR-B:50 mA **Direct Power(Non-Reverse Polarity):130 Condition Duration mA limited by panel.Reverse Polarity Power: Initial LED 80 seconds 30 mA for the 2WTA-B in alarm;12 mA for all status other 2WTA-B units on the loop.Add 25 mA indication for the RRS-MOD reversing relay alarm current. Architect/Engineer Specifications Alarm Contact Ratings 2-wire:n/a Smoke detector shall be a System Sensor i3 Series model number , 4-wire:0.5 A @ 30 V AC/DC listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Form C Contact Ratings 2 A @ 30 V AC/DC Systems.The detector shall be a combination photoelectric/thermal Physical Specifications equipped with a sounder(model 2WTA-B,4WTA-B),a Form C relay(model 2VVTR-B),a combination sounder/relay(model 4WTAR-B),or an isolated Operating Temperature 32°F to 100°F(0°C to 37.8°C) thermal/sounder/relay(model 4WITAR-B).The detector shall include a Range mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang, Operating Humidity 0 to 95%RH non-condensing and 4-inch square back boxes with a plaster ring,or direct mount to the Range ceiling using drywall anchors.Wiring connections shall be made by means Thermal Sensor 135°F(57.2°C)fixed of SEMS screws.The detector shall allow pre-wiring of the base and the Freeze Trouble 41°F(5°C) head shall be a plug-in type.The detector shall have a nominal sensitivity Sensitivity 2.5%/ft.nominal of 2.5 percent per foot as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift Input Terminals 14-22 AWG compensation and smoothing algorithms.The detector shall provide dual- Dimensions(including 5.3 inches(134 mm)diameter,2.0 inches color LED indication that blinks to indicate power-up,normal standby,out of base) (51 mm)height sensitivity,alarm,and freeze trouble conditions.When used in conjunction Approximate Weight 7.1 oz(200 g) with the 2W-MOD2 module,2-wire models shall include a maintenance Sound Pressure Output 85 dBA(models 2WTA-B,4WTA-B,4WTAR-B, signal to indicate the need for maintenance at the alarm control panel and and 4WITAR-B only) shall provide a loop testing capability to verify the circuit without testing each Mounting 311/z inch octagonal back box,4-inch octagonal detector individually.When used in conjunction with the RRS-MOD module, back box,single gang back box,4-inch square all i3 sounder models on a loop shall sound when one sounder alarms,all shall back box with a plaster ring,direct mount to be synchronized,and all sounders may be silenced from the panel. ceiling Ordering Information Model Thermal Wiring Alarm Current Model Description 2WTA-B Yes 2-wire 130 mA max.limited by RRS-MOD Reversing relay/synchronization module control panel 2W-MOD2 2-wire loop test/maintenance module 2WTR-B Yes 2-wire 130 mA max.limited by SENS-RDR Sensitivity reader control panel RT Removal/replacement tool 4WTA-B Yes 4-wire 35 mA A77-AB2 Retrofit adapter bracket 4WTR-B Yes 4-wire 35 mA 4WTAR-B Yes 4-wire 50 mA 4WITAR-B Yes 4-wire 50 mA *--. SYSTEM 02009 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Vsit systemsensor.com for �� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0348-004.6/09•#2170 SYSTEM SENSOR • i4 Series . . Combination CO/Photoelectric w Smoke Detector • f1 • Best-in-class carbon monoxide(CO)and smoke detection technology in a single, system-connected device. Features Integration:The i4 Series combines CO and smoke detection into one device, requiring less wiring and fewer back boxes than • Single device for CO and smoke detection that uses less wiring two separate devices.The i4 Series is compatible with i3(2WTA-B and fewer junction boxes or 4WTA-B),so an attractive CO monitoring solution can easily be • Compatible with a wide range of control panels with the use of the retrofitted into existing i3 installations.The i4 Series CO cell can be required i4 Interface Module. easily replaced at end-of-life, resulting in a much lower life cost than • Sends distinct smoke and CO signals to the panel having to replace the entire detector. • Sounds Temporal 3 for smoke and Temporal 4 for CO Installation ease:The i4 Series Combination CO/Smoke detector • Built-in 85dB sounder requires less wiring than two separate CO and smoke devices. • LEDs display both CO and smoke status Installers can pre-wire its plug-in base,while its large wire-entry port External IR LED provides extended range sensitivity testing and in-line terminals provide ample room for neatly routing wiring.The • base accommodates several back box options and also direct mounts • Versatile mounting allows for wall or ceiling placement using drywall anchors.The i4 head plugs into the base with a simple • Easily replaceable electrochemical CO cell with 6-year end-of-life Stop-Drop'N LockTM action.When the detector's CO cell reaches end- timer that signals the panel and chirps to alert the homeowner of-life,it can be easily replaced in the field without a tool. • RealTest®enables functional test using canned CO Intelligence:With the help of the module,the i4 Series transmits • Drift compensation and smoothing algorithms provide false distinct CO and smoke signals,allowing appropriate response alarm immunity from the central monitoring station. Intelligent features,such as drift • Compatible with SENS-RDR sensitivity tester compensation and smoothing algorithms, reduce nuisance alarms. • Full agency compliance with UL 268 and UL 2075 Instant inspection:The i4 Series LEDs enable instant inspection of detector status signaling normal/standby condition,alarm condition,maintenance/trouble condition or functional test mode. 2-wire devices allow loop testing via the EZ Walk feature where wiring can easily be verified by checking the LED status at each detector. Smoke sensitivity can be easily measured using the wireless SENS- RDR device.CO cell functionality can also be quickly validated in the field with canned CO per NFPA 720:2009 requirements using the Agency Listings detector's RealTest functionality. ,T U o 4, rt LISTED S268 1653:0227 i4 Series Combination CO/Smoke Detector Specifications Carbon monoxide(CO)/Smoke detector shall be a System Sensor model number COSMO-2W(2-Wire)/COSMO-4W(4-Wire)listed to UL 268 for Fire Protection Signaling Systems and to UL 2075 for Carbon Monoxide Gas Detection.The detector shall be photoelectric smoke sensing and electrochemical CO sensing and equipped with a sounder capable of Temp 3 and Temp 4 audible signals.The detector shall have nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector's base shall be able to mount to a single-gang electrical box or direct(surface mount)to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide LED indication that blinks to indicate normal standby,smoke alarm,smoke maintenance,CO alarm,CO trouble/end-of-life.When the detector is in CO trouble condition,it shall send a trouble signal to the panel.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The 2-wire model shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually.The detector shall have a replaceable CO cell that can be replaced at end of cell life. Electrical Specifications Operating Voltage(VDC): Nominal: 12/24;Minimum:8.5;Maximum:35 Maximum Standby Current: 50 pA Maximum Alarm Current: 2-Wire 50mA;4-Wire 40mA Audible Signal: 85 dBA Maximum Reverse Polarity Current: 20 mA Maximum Start-up Current: 200uA Maximum Start-up Capacitance: .10 pF Physical Specifications Dimension: Diameter:5.5 Depth:2.5"(includes base) Weight: 9.2 oz.(261 g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 20-95%RH Storage Temperature Range: -10—70°C(14—158°F) Sensitivity: 2.5%/ft nominal Input Terminals: 14 to 22 AWG Mounting: Back boxes:3.5"and 4"Octagonal;Single-gang;4"Square;2 x 4",3.5"and 4"round ceiling. Direct mount to wall or ceiling. Operation Modes/LED Status Green Red Blue Sounder Alarm Smoke: Off On Off Temp 3 Alarm CO: Off Off On Temp 4 Alarm Smoke&CO: Off On On Temp 3 Power Up: Blink 5 sec. Blink 5 sec Blink 5 sec. Off Standby: Blink 5 sec. Off Off Off RealTest®Mode(CO): Off Off Blink 1 sec. Off After CO is Sprayed: Off Off On Temp 4 Smoke Maintenance: Off Blink 5 sec. Off Off CO Trouble: Off Off Blink 5 sec. Off End-of-Life: Off Off Blink 5 sec. Intermittent i4 Series Interface 11i and Reversing • Y Relay Module • • 4 The i4 Interface Module connects up to 12 detectors to a + wide range of control panels using only 2 to 3 zones. It also interconnects the devices, so when one device alarms, they all sound. Features Integration:The i4 module allows up to 12 i4 Series or compatible • Easily integrates up to 12 compatible detectors to a wide range of i3 Series smoke detector models to be integrated into a fire alarm panel using only 2 to 3 zones:a smoke zone,a CO zone and an control panels optional trouble zone. Detectors sound Temp 3 for smoke and Temp • 2-wire module is compatible with COSMO-2W combination 4 for CO events.The i4 module can be used to alarm all sounders in detectors and 2WTA-B smoke detectors. compatible detectors for smoke and CO events.When one detector • 4-wire module is compatible with COSMO-4W combination detects smoke or CO and goes into alarm,all connected detectors detectors and 4WTA-B smoke detectors. alarm,offering the highest level of warning to the homeowner. • Sends distinct smoke and CO signals from i4 detectors to the panel Installation ease:The i4 Series Interface Module mounts to a • LED indication shows when a detector on the loop requires 411/16-inch square back box for quick and easy installation.Terminal cleaning or maintenance(2-wire detectors only) blocks with durable SEMS screws ensure a reliable connection. It • Initiates the EZ Walk loop test(2-wire detectors only) also has pre-drilled holes for easy mounting inside a metal enclosure • Module interconnects the sounders of all devices connected to it. Intelligence:The i4 Interface Module allows i4 and compatible i3 No RSS-MOD is required.Optional trigger inputs are provided to sound multiple modules. smoke detector models(2WTA-B and 4WTA-B)to communicate with any listed fire alarm control panel capable of utilizing this module. Instant inspection:The i4 Interface Module provides LED status indication for the loop,displaying normal operation,loop wiring fault, smoke events,smoke maintenance(2-wire only),CO events,and CO maintenance/end-of-life. Agency Listings s kRvi LISTED SHI 1653:0228 i4 Series Interface Module Specifications The i4 module shall be a System Sensor i4 Series model number COSMOD2W(2-wire)or COSMOD4W(4-wire)listed to UL 864 and UL 985 for Control Units for Fire Protection Signaling Systems.The module shall include provisions for mounting to 4-inch square back box. Wiring connections shall be made by means of SEMS screws.The module shall provide 4 LED indicators that blink or illuminate to indicate communication status,maintenance alert,alarm or freeze trouble conditions,and EZ Walk loop test mode(2-wire module only).The module shall allow communication to i4 Series and i3 Series detectors with sounders with any UL 864-and UL 985-listed fire alarm control panel capable of utilizing this module.The 2-wire module shall offer provisions for Style D/Class A wiring on IDC loops and shall provide a loop testing capability(EZ Walk)to verify the initiating loop wiring. Electrical Specifications Module Operating Voltage(VDC): Nom.: 12/24;Min.:8.5(2-wire), 10(4-wire,power limited);Max.:35 VDC(power limited) Standby Current: 2-Wire:61mA(max.),45mA(12V In),26mA(24V In); 4-Wire:52mA'(max.),37mA'(12V In),22mA'(24V In) Alarm Current2: 2-Wire: 181 mA(max.), 121 mA(12V In),64mA(24V In); 4-Wire:78mA'(max.),57mA'(12V In),34mA'(24V In) Maximum Ripple Voltage: 30%of applied power Maximum Alarm Threshold: 9.2 Volts DC Alarm and Maintenance Contact Rating: 100 mA I@ 36 Volts DC,resistive,25 ohms Maximum Loop Wiring Resistance: 2-Wire 50 Ohms;4-Wire 300 Ohms Trigger inputs: Min On Voltage: 1.5V;Max.:Vin Does not include current draw from attached detectors or EOL relay.2 Does not include reverse polarity current draw from attached detectors. Physical Specifications Module Dimension: Height:6.04 Width:6.04 Depth: 1.00" Weight: 9.6 oz.272(g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 5-95%RH Storage Temperature Range: -20—70°C(-4—158°F) Input Terminals: 14 to 22 AWG Mounting: 411/16"square back box or inside a metal enclosure Operation Modes/LED Status Green Yellow Red Blue Alarm Smoke: Blink 1 sec. Off On Off Alarm CO: Blink 1 sec. Off Off On Alarm Smoke&CO: Blink 1 sec. Off On On No power/No communication: Off Off Off Off Loop wiring fault: Blink 1 sec. On Off Off EZ Walk Test Mode(2-wire only): Blink 1 sec. Blink 5 sec. Off Off Smoke Maintenance(2-wire only): Blink 1 sec. Off Blink 5 sec. Off Smoke Freeze Trouble(P 2WTA-B only): Blink 1 sec. Off Blink 10 sec. Off CO Trouble: Blink 1 sec. Off Off Blink 5 sec. Module Power-Up Sequence/LED Status Condition Duration Maintenance/Freeze trouble LED indication 6 minutes EZ Walk test available 6 minutes after power up or panel reset Ordering Information Part No. Description COSMO-2W 12/24 volt,2-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMO-4W 12/24 volt,4-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMOD2W 2-wire interface module(required to use with COSMO-2W models) COSMOD4W 4-wire interface module(required to use with COSMO-4W models) CO-REPL Replacement CO cell for COSMO-2W and COSMO-4W models SENS-RDR Sensitivity reader EOLR-1 End-of-line relay(required with 4-wire systems) *Th_ SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2013 System Sensor. Phone:800-SENSOR2•Fax 630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com SEw SO� for current product information,including the latest version of this data sheet. ,vJ www.systemsensor.com CODS30302•11/13 SYSTEM �$ SENSOR r P Selectable Output •I Y� Horns, Strobes, and Horn Strobes SpectrAlert®Advance selectable-output horns,strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTF',4N�ert A N Features The SpectrAlert Advance series offers the most versatile and •Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. With white and red plastic housings,wall and ceiling mounting •Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance can •Automatic selection of 12-or 24-volt operation at 15 and 15/75 meet virtually any application requirement. candela •Field-selectable candela settings on wall and ceiling units:15,15/75, Like the entire SpectrAlert Advance product line,horns,strobes, 30,75,95,110,115,135,150,177,and 185 and horn strobes include a variety of features that increase their •Horn rated at 88+dBA at 16 volts application versatility while simplifying installation.All devices •Rotary switch for horn tone and three volume selections feature plug-in designs with minimal intrusion into the back box,which make installations fast and foolproof while virtually •Universal mounting plate for wall and ceiling units eliminating costly and time-consuming ground faults.Furthermore, •Mounting plate shorting spring checks wiring continuity before a universal mounting plate with an onboard shorting spring tests device installation wiring continuity before the device is installed,protecting devices •Electrically compatible with existing SpectrAlert products from damage. •Compatible with MDL sync module In addition,field-selectable candela settings,automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGNALING O 41i> MEA roved (indstrobes) LISTED APPROVED approved 7125-16531887125-1653:186(hornoor strobes, 54011(chimes,horn strobes,horns) 3023572 MEA452-05-E chime strobes) S5512(strobes) 7135-1653:189(horns,chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync-Circuit-Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30, 75,95,110,115,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16x 411/16 x 21/a-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Rangez 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm Lx 119 mm W x 33 mm D) Wall-Mount Back Box Skirt Dimensions(BBS-2,BBSW-2) 5.9"L x 5.0"W x 2.2"D(151 mm L x 128 mm W x 56 mm D) Ceiling-Mount Back Box Skirt Dimensions(BBSC-2,BBSCW-2) 7.1"diameter x 2.2"high(180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS,TRW-HS) 5.7"L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) Ceiling-Mount Trim Ring Dimensions(sold as a 5 pack)(TRC-HS,TRCW-HS) 6.9"diameter x 0.35"high(175 mm diameter x 9 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12V nominal only for 15 and 15/75 cd. A05-0395-007 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. A05-0395-007 SpectrAlert Advance Dimensions 1156111 dH Wall-mount horn strobes Ceiling-mount horn strobes 7.1" r-2.251 5.05"� �—2.231 \ Dia. 0 1 I I 70 0 o 0 a\\ r 00000 I, 5.98" ! r I0 a , o l :0 00 ¢ \o o di/ c o ��� o t Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Ceiling Strobes P2R*t 2-Wire Horn Strobe,Standard cd$,Red SCR Strobe,Standard cd,Red P2RH* 2-Wire Horn Strobe,High cd,Red SCRH Strobe,High cd,Red P2W* 2-Wire Horn Strobe,Standard cd,White SCW* Strobe,Standard cd,White P2WH* 2-Wire Horn Strobe,High cd,White SCWH Strobe,High cd,White P4R* 4-Wire Horn Strobe,Standard cd,Red Horns P4RH 4-Wire Horn Strobe,High cd,Red HR Horn,Red P4W 4-Wire Horn Strobe,Standard cd,White HW Horn,White Wall Strobes Accessories SR*t Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red SRH*t Strobe,High cd,Red BBSW-2 Back Box Skirt,Wall,White SW* Strobe,Standard cd,White BBSC-2 Back Box Skirt,Ceiling,Red SWH* Strobe,High cd,White BBSCW-2 Back Box Skirt,Ceiling,White Ceiling Horn Strobes TR-HS Trim Ring,Wall,Red PC2R* 2-Wire Horn Strobe,Standard cd,Red TRW-HS Trim Ring,Wall White PC2RH 2-Wire Horn Strobe,High cd,Red TRC-HS Trim Ring,Ceiling,Red PC2W*t 2-Wire Horn Strobe,Standard cd,White TRCW-HS Trim Ring,Ceiling,White PC2WH* 2-Wire Horn Strobe,High cd,White PC4R 4-Wire Horn Strobe,Standard cd,Red PC4RH 4-Wire Horn Strobe,High cd,Red PC4W 4-Wire Horn Strobe,Standard cd,White Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P. t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SR. t"Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. *--. SYSTEM m2009 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Vsit systemsensoccom for �� SENSOR Phone:800-SENSOR2•Fax:630-377-6495 current product information,including the latest version of this data sheet. A05-0395-007.4/09•#2132 INSTALLATION AND MAINTENANCE INSTRUCTIONS SYSTEM 0, w 00 .4 SENSOR® Series Interface Module 3825 Ohio Avenue,St.Charles,Illinois 60174 COSMOD2W and COSMOD4W 1-800-SENSOR2,FAX:630-377-6583 *For use with COSMO-2W and COSMO-4W detectors www.systemsensor.com SPECIFICATIONS Electrical Specifications Power Supply Voltage: Resettable power;2-Wire:Min.8.5 Volts DC(Power limited);Max.35 Volts DC(Power limited); 4-Wire:Min.10 Volts DC(Power limited);Max.35Volts DC(Power limited) Device Power-up Time: 200 milliseconds Max.Standby Current: 2-Wire:62mA;4-Wire:52mA(Does not include current draw from attached detectors or EOL relay) Max.Alarm Current: 2-Wire: 174mA;4-Wire:75mA(Does not include reverse polarity current draw from attached detectors) Nom.Standby Current: 2-Wire:45mA@12V,27mA@24V;4-Wire:36mA@12V,21mA@24V (Does not include current draw from attached detectors or EOL relay) Alarm Contact Rating: 100 mA @ 36 Volts DC,resistive,25 ohms Maintenance Contact Rating: 100 mA @ 36 Volts DC,resistive,25 ohms Max.IDC Loop Wiring Resistance: 2-Wire:50 Ohms;4-Wire:300 Ohms Trigger Inputs: Min.On Voltage: 1.5V;Max.On Voltage=Vin Aux Power Out: Same Voltage as Input Power(Unregulated,limited to 250mA) Min.Reset Time: 300 milliseconds Initial Communication Cycle: 6 minutes EZ Walk Test Availability: 6 minutes after power up or panel reset Physical Specifications Operating Temperature Range: 0-50°C(32-122°F) Operating Humidity Range: 5-95% RH Storage Temperature Range: -20-70°C(-4-158°F) Height: 6.04 inches Width: 6.04 inches Depth: 1.16 inches Shipping Weight: 0.6 lbs Wire Gauge Acceptance: Min:22 AWG;Max: 14 AWG 2-wire Compatibility Requirements Min.Loop Voltage: 12.9 Volts DC Max.Loop Voltage: 14.5 Volts DC Max.Loop Resistance: 50 Ohms Max.Loop Ripple: 240 mVpp Max.Loading Capacitance: 0.01 mF Max.Alarm Current: 46 mA Max.Reset Voltage: 0.30 Volts DC Alarm Delay: n/a Min.Alarm Reset Time: 0.3 seconds Max.Normal Load Current: 2.4 mA Zone Type: Standard EOL Device: 3.9k Ohms(+-5%) Loop Style: B and D Compatibility Zone Identifier: A Detector Zone Identifier: A Max.Detectors Per Zone: (12)2-wire i4 series model#COSMO-2W and/or i3 series model#2WTA-B detectors BEFORE INSTALLATION The i4 COSMOD2W, 2-wire interface module, offers additional functionality This information is included as a quick reference installation guide. Refer to including: the control panel installation manual for detailed system information. If the module will be installed in an existing operational system,inform the operator • Ability to query for a "need for maintenance" condition from 2-wire i4 and local authority that the system will be temporarily out of service.Discon- series model COSMO-2W and i3 series model 2WTA-B smoke detectors nect power to the control panel before installing the module. • One relay is available to indicate a multitude of maintenance conditions Notice: This manual should be left with the owner/user of this equipment. at the control panel This product is intended for use in ordinary indoor locations. • All conditions are displayed at the module and at the detector GENERAL DESCRIPTION The i4 series module is designed to interface between compatible i4 series • EZ Walk test mode allows the installer to easily verify that all detectors combination CO/smoke detectors (Model COSMO-2W and COSMO-4W) and on a loop are operational compatible security/fire panels. It can also be used to retrofit compatible i4 • Allows 2-wire smoke detectors to be used on any compatible 4-wire series detectors into an existing loop of i3 smoke detector models 2WTA-B or control panel and provides Style D wiring on the detector loop 4WTA-B,without adding wires.The module interprets signals and translates FEATURES them into a separate smoke zone and a separate CO zone, each with alarm • Compatible with System Sensor i4 series combination CO/smoke detectors and trouble signals.When signaled by the panel,a module will synchronize and System Sensor i3 Series smoke detectors models 2WTA-B or 4WTA B. connected detector sounders in either Temporal 3 or Temporal 4 pattern.Local status indication is provided by 4 LED's and a 3 position DIP switch enables • Allows up to 12 compatible devices including the i4 series combination user configuration. CO/smoke detector to be integrated with a panel SS-500-004 1 156-3871-001 • Allows sounder activation of all detectors on loop in either Temporal 3 A CO alarm is self-clearing.Once a CO alarm has been signaled,the blue LED or Temporal 4 pattern will illuminate. Once the initiating device ceases to signal the CO event,the VISIBLE ANNUNCIATON blue LED will turn off. If a CO alarm is signaled, and not cleared,prior to a The i4 series interface module has four visible LED's:The green LED is a su smoke alarm condition, the module will keep both the blue and red LED's pervisory LED;it blinks during power on,reset,and during normal operation. illuminated.If a smoke alarm is signaled first,the module will not be able to The yellow LED is used to indicate a loop wiring fault and will blink when it receive notification of a CO alarm condition and will not be able to report it is in EZ Walk test mode.The red LED signals smoke events;it blinks during to the panel. smoke maintenance events and lights constantly during smoke alarm events. MAINTENANCE The blue LED signals CO events;it blinks during CO trouble or CO end-of-life, This condition means one or more detectors on the loop have a smoke main- and lights constantly during CO alarm. tenance issue.See"Smoke Maintenance Inquiry"section for further details. FIGURE 1:MODULE FRONT VIEW FREEZE TROUBLE \ This condition means one or more detectors on the loop are measuring the ambient temperature is near the freezing point.See"Freeze Trouble Inquiry" O section for further details. CO TROUBLE Green LED ► p .,,,ca,.,,,tecomax The module can be notified of a detector with a CO trouble condition.All CO Yellow LED ► p r wm Xi .x100F trouble conditions will be reported on the CO zone and displayed with a blink- Red LED ► ©"""Q, '•""""' ing blue LED. The module is not able to determine the number of detectors °X'"101¢"`""' that have a CO trouble condition or which trouble condition exists. Blue LED O.Q X1XXt23 EZ Walk Test Switch MIBeroXFZwAutlsT INSTALLATION (2-wire only) ► CR � rtDITICIDOUBLE MOUNTING 4JKIlANISTA1W' I O CAUTION The module can be mounted to a 4-"/16 inch back box or inside a listed,dedi- DEENmGI UNIT enclosure.When mounting inside an enclosure with pre-stamped holes, PRIOR TO SERVIGNB it may be easier to align the bottom screw hole first.It is not necessary to use the module cover when mounting inside an enclosure. S0331-00 TABLE 1:OPERATION MODES FIGURE 2:MOUNTING OPERATION GREEN YELLOW HOLE FOR MOUNTING TO VISTA ENCLOSURE MODE LED LED RED LED BLUE LED (No.6x3/4 Type AB) Normal(standby) Blink 5 Sec. OFF OFF OFF e' No power/ 11 16; CO Ilq OFF OFF OFF OFF Non-operational \I i� aaa o v Loop wiring fault Blink 5 Sec. ON OFF OFF � --- � I � O EZ Walk Test Mode Blink 5 Sec. Blink 5 Sec. OFF OFF O [ � (2-wire only) iI A mi Alarm Smoke Blink 5 Sec. OFF ON OFF al O i am Alarm CO Blink 5 Sec. OFF OFF ON f O iI Alarm Smoke&CO Blink 5 Sec. OFF ON ON 611 I I- © I�N1 i u� Maintenance Blink 5 Sec. OFF Blink 5 Sec. OFF � (2-wire only) 8 NC' 0 Freeze Trouble(2- Blink 5 Sec. OFF Blink 10 Sec. OFF 1 wire only) CO Trouble Blink 5 Sec. OFF OFF Blink 5 Sec. SLOTS FOR MOUNTING SLOT FOR MOUNTING TO VISTA ENCLOSURE TO 4-11/16 JUNCTION BOX 0331-00 NORMAL(STANDBY) (No.6x5/16Type AB or Type F) The module is powered and detectors on the loop are operating normally. WIRING GUIDELINES NO POWER/NON-OPERATIONAL All wiring must be installed in compliance with the NFPA 70 standards,Na- Power is not applied to the module or communication between the module tional Electrical Code, applicable state and local codes, and any special re- and the detectors on the loop is unsuccessful. quirements at the local Authority Having Jurisdiction(AHJ). LOOP WIRING FAULT The screw terminals in the mounting base will accept 14-22 gauge wire.Wire If an open circuit occurs on the loop,the module will indicate the condition connections are made by stripping approximately 1/a" of insulation from the by illuminating the yellow LED.2-wire units will then power the style-D ter- end of the feed wire,inserting it into the proper base terminal,and tightening minals.When the wiring issue on the loop has been resolved,the module will the screw to secure the wire in place. Do not put wires more than 2 gauge turn the yellow LED off. apart under the same clamping plate. EZ WALK TEST MODE Note: The module must be installed in the same room and within 20 feet of This indicates the module and detectors are in EZ Walk Test Mode.See"EZ Walk the panel and enclosed within conduit or equivalently protected against me- Test"section for instructions on how to initiate and perform the EZ Walk test. chanical injury. ALARM SMOKE/ALARM CO/ALARM SMOKE&CO A smoke alarm will be indicated by the red LED.A CO alarm will be indicated AWARNING by the blue LED. Remove power from alarm control unit or initiating device circuits before in- A smoke alarm is not self-restoring. Once a smoke alarm has been signaled, stalling detectors. the red LED will illuminate until the module is reset by removal of power. Note:On some panels,resetting a smoke alarm may require additional steps at the keypad to clear the trouble conditions on CO and smoke mainte- nance zones due to power loss to the module. SS-500-004 2 156-3871-001 FIGURE 3:COSMOD2W WIRING DIAGRAM ALL CIRCUITS ARE SUPERVISED Note:See Table 3 for dip (EXCEPT TRIGGERS)AND MUST switch configurations SMOKE 0 BE POWER LI MITER AUXPOWER O O (resettable) 1 C °° i�� Opp9����� 1®10 � [_I r� �5 �o SMOKE O �r_1 © , 1 L1 Panel �/ ®� 0 [ 71 Resistors A ZONE O [:.I F o �i ® 14)J �o ' i 3.9k �� r� EI )I RESISTOR I I (IB 1- O LSF I I ea7 /O o I (suppled Ic0 I +� , ® with module) CO Q I + IQ ® 'ZONE 0 I (.,;, /-6`—'4, --.-) n B lI I \$ ' __,. /.0\ r/ I MAI NT. O COSMOD2W I LOOP STYLED WIRING I ZONE O EOL I COSMO 2W BELL [ 5f. Resistor , OR F —I SMOKE I TRIGGER OUT43 50329-00 CO TRIGGER , OUT FIGURE 4:COSMOD4W WIRING DIAGRAM ALL CIRCUITS ARE SUPERVISED SMOKE Q (EXCEPT TRIGGERS)AND MUST BE POWER LIMITED POWER O (resettable) Q °o Ela I vol) p �Panel oil ET SMOKE , �� EOL _ P oQ o * oo ZONE oflel © - 111 N 3.9k CO 0 _ __�I,VI © 1 — _ — /��� ���; RESISTOR f "I— �� �," (supplied ZONE Q e e with module) COSMOD4W COSMO-4W I , BELL 10, I OR : I SMOKELI J I 50330-00 I TRIGGER OUT I CO TRIGGER OUT L a / + `\ FIGURE 5:MODULE TERMINALS l OO 0 %In LJ \POWER IN + Na P ®I , •SMOKE ZONE EOL RESISTOR POWER IN— , a © j (VALUE DEFINED BY PANEL) SMOKE ALARM CONTACT © ICI, CO ZONE EOL RESISTOR t3•-,l ISI (VALUE DEFINED BY PANEL) MAINTENANCE TROUBLE RELAY CONTACT O O- 1 IDC+ (COSMOD2W ONLY) �+� II IDC— CO ALARM CONTACT I 14I O Sle — STYLE D+(4-WIRE DETECTOR POWER+) vI © IC I� STYLE D—(4-WIRE DETECTOR POWER—) CO TRIGGER I SMOKE TRIGGER/BELL IN i O � � O ~ ® O 50334-00 SS-500-004 3 I56-3871-001 WIRING DIAGRAMS FREEZE TROUBLE INQUIRY Install module wiring in accordance with appropriate wiring diagrams. The module sends a freeze trouble inquiry to the detectors every four hours. (Figure 3 and Figure 4) (Compatible i3 Series 2-wire smoke detectors only) If a response indicating a The module relays have a maximum ON resistance of 25 ohms. This resis- freeze problem is received,the red LED on the module will blink once every tance plus the wiring resistance to the panel must be less than the maximum 10 seconds and a smoke maintenance condition will be indicated to the panel. zone wiring resistance stated in the panel manual. TESTING INPUT TRIGGERS/SOUNDER ACTIVATION Modules must be tested after installation and following periodic maintenance. Many panels can be programmed with triggers which are auxiliary relays that Testing should be performed at least once per year. activate upon an alarm condition. Two inputs are used to signal the module NOTE:Before testing,notify the proper authorities that the system will be tem- to activate device sounders.The first is configurable by DIP switch to one of porarily out of service. Disable the zone or system to prevent any unwanted two modes;bell in or smoke trigger.When in the bell mode,the module will alarms. follow a valid coded signal from a Bell Out/NAC circuit consisting of high to EZ WALK TEST low,then low to high for less than 1.9 seconds each. In smoke trigger mode, The communication loop between the 2-wire modules and detectors can be while the input is held high,the module will synchronize the detectors in a manually tested by putting the module and detectors into EZ Walk test mode. Temporal 3 pattern. This feature is for use with System Sensor detectors(i4 series model COSMO-2W The second input is for a CO trigger;the CO trigger input allows a single mod- and i3 series model 2WTA-B)installed with the model COSMOD2W module. ule to have CO silence/hush capability and allows multiple module installa- The EZ Walk loop test verifies the initiating loop wiring and provides visual tions to have all sounders activated in Temporal 4 in the event of a CO alarm. status indication at each detector: While the CO trigger is held high,the module will synchronize the detectors in a Temporal 4 pattern.After 30 minutes in Temporal 4 alarm,the time period 1. Ensure proper wiring and power is applied. Wait approximately 5 min- between the Temporal 4 pulse will change from 5 seconds to 60 seconds. utes from power-up before performing the EZ Walk test.The green LED on the module must be blinking indicating the module is in ready/ Note: CO trigger may not be used with UL 864 panels.All detectors will sound standby mode to start the EZ Walk mode. with no triggers connected,however,hush capability is not enabled. TABLE 2:DIP SWITCH CONFIGURATIONS 2. Locate the EZ Walk recessed test switch located behind the module cover (See Figure 1).Depress the test switch with a small screwdriver. The yel- DIP SWITCH#1 DIP SWITCH#2 DIP SWITCH#3 low LED will blink showing that the module and detectors are in EZ Walk Smoke Maint on mode for 5 minutes. ON Bell In Smoke Trouble and Unused 3. Observe the LEDs at each detector to make sure the green LED is double (DEFAULT) Form-B Maint Relay blinking every 5 seconds as listed in Table 3. (COSMOD2W only) 4. At the end of the five minute period,the module will terminate EZ Walk Smoke Maint on and the yellow LED will stop blinking. The EZ Walk test period can be Form-B Smoke main- extended bypressingthe test switch multiple times.Each press will add OFF Smoke Trigger Unused P tenance Relay only 5 minutes of additional time. (COSMOD2W only) If a module or detector fails the test, its wiring should be checked. If the POWER UP AND COMMUNICATIONS module still fails,it should be replaced.Notify the proper authorities when all COMMUNICATIONS CHECK(2-WIRE ONLY) testing has been completed. Upon power up,the module will send a request for communication check.All compatible detectors on the loop that understand the communication protocol NOTE:The EZ Walk loop test should not be used in lieu of functional testing will respond.If all detectors respond correctly,the green LED will blink once (alarm,trouble and other functional tests)of the system. every 5 seconds. If the module does not get a response, it will turn off the TABLE 3:EZ WALK TEST DETECTOR MODES green LED and continue to try every 2 minutes until a response is received. DETECTOR DETECTOR SMOKE MAINTENANCE INQUIRY GREEN LED RED LED The module sends a smoke maintenance inquiry to the detectors every 24 PROPER OPERATION Double Blink 5 Seconds OFF hours. (Compatible 2-wire detectors only) If a response indicating a mainte- nance problem is received,the red LED on the module will blink once every 5 OUT OF SENSITIVIY OFF Double Blink 5 Seconds seconds and a smoke maintenance condition will be indicated to the panel.It is likely that the detector needs to be cleaned or replaced,refer to the detector FREEZE CONDITION OFF Double Blink 10 Seconds instruction manual for maintenance instructions. FCC STATEMENT This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:(1)This device may not cause harmful interference,and(2)this device must accept any interference received,including interference that may cause undesired operation. NOTE:This equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates,uses and can radiate radio frequency energy and,if not installed and used in accordance with the instructions,may cause harmful interference to radio communications.However,there is no guarantee that interference will not occur in a particular installa- tion.If this equipment does cause harmful interference to radio or television reception,which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. THREE-YEAR LIMITED WARRANTY System Sensor warrants its enclosed product to be free from defects in materials and # ,3825 Ohio Avenue,St.Charles,IL 60174.Please include a note describing workmanship under normal use and service for a period of three years from date of the malfunction and suspected cause of failure.The Company shall not be obligated to manufacture.System Sensor makes no other express warranty for the enclosed product. replace units which are found to be defective because of damage, unreasonable use, No agent,representative,dealer,or employee of the Company has the authority to in- modifications,or alterations occurring after the date of manufacture.In no case shall the crease or alter the obligations or limitations of this Warranty.The Company's obligation Company be liable for any consequential or incidental damages for breach of this or any of this Warranty shall be limited to the replacement of any part of the product which other Warranty,expressed or implied whatsoever,even if the loss or damage is caused by is found to be defective in materials or workmanship under normal use and service the Company's negligence or fault.Some states do not allow the exclusion or limitation of during the three year period commencing with the date of manufacture.After phoning incidental or consequential damages,so the above limitation or exclusion may not apply System Sensor's toll free number 800-SENSOR2 (736-7672) for a Return Authorization to you.This Warranty gives you specific legal rights,and you may also have other rights number,send defective units postage prepaid to:System Sensor,Returns Department,RA which vary from state to state. SS-500-004 4 I56-3871-001 ©2012 System Sensor i4 Series Combination Carbon Monoxide(CO)/Photoelectric Smoke Detector it4 COSMO 4W (4 wire) Wiring Diagram PANEL (4-wi re) SMOKE 0- i4 MODULE* i4 DETECTOR POWER O r N _ (resettable) , D- 923 �I lIi 0 —®llc___ l Panel Eo SMOKE EOL ol RELAV ZONE I SII l Resistors / \ 4wlR: \ . FOLK-, 0 as I { cra -011 6 �l O El III7H 3.9k CO - (�I © Imo, 9/ RESISTOR - - 0 r - - -+(• ! [®JI - , ` I (supplied I `ZONE 0 with module) 0 71 1 `� � � I COSMOD4W � COSMO-4W I BELL 0- -i I OR I I I i4 MODULE TERMINALS F -I J SMOKE TRIGGER OUT //i 144,1_ J I I � � O1:11 QI POWER IN+ MiIG}Il1 1�IM� CO ■-II«'�7 �"�� SMOKE ZONE EOL RESISTOR TRIGGER r J POWER IN- 151 © I-. �-■ (VALUE DEFINED BY PANEL) ■�Il� I-■ CO ZONE EOL RESISTOR QST** J SMOKE ALARM CONTACT i ■ (VALUE DEFINED BY PANEL) MAINTENANCE TROUBLE RELAY CONTACT i O IDC+ ■-III-■DIP SWITCH CONFIGURATIONS (COSMOD2W ONLY) iIDC■ Wili }.-I STYLE D/CLASS A+(4-WIRE DETECTOR POWER+) DIP SWITCH#1 DIP SWITCH#2 DIP SWITCH#3 CO ALARM CONTACT ■ iji1 ■ l OSTYLED/CLASSA–(4-WIRE DETECTOR POWER–) ONSmoke Maint on Smoke Trouble CO TRIGGER lii] lSMOKE TRIGGER/BELL IN (DEFAULT) Bell In and Form-B Maint Relay Unused -' (COSMOD2W only) I 8Ick— O 7c9 171 I Smoke Maint on Form-B OFF Smoke Trigger Smoke maintenance Relay only Unused ° � 0 `� J (COSMOD2W only) COSMOD4W �� SYSTEM Module is also compatible withSmoke Detector **Triggers are optional and can bee used used to interconnect multiple modules with a bell output or positive voltage from the panel. �� SENSOR' Please consult panel manufacturer for programming outputs advanced ideas.advanced solutions° ***Up to 12 detectors per module;models COSMO-4W or 4WTA-B only. Module interconnects sounders of both devices(RSS-MOD not needed). ©lois System sensor.coFL8lo2•7/13