Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A18-0021_Approved documents_1525985311.pdf
75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Fire - Construction Permit A18-0021 Issued: 05/10/2018 TOWN OF VAIL Property Information Address: 22 W MEADOW DR (210107108999) ( 210107108999 ) Unit #: Parcel Number: 210107108999 Legal Description: Contacts Contact Type: Applicant Full Name: Karen Morgan Address: PO Box 534 730 Nottingham Road Avon, CO 81620 Phone: 9709494638 Contact Type: Property Owner Full Name: Common Area Address: Phone: None Contractor Contractor Type: Alarm Company: Xssentials By Thul Electronics State License #: Phone: 970-949-4638 Project Information Project Name: Villa Cortina Alarm 2018 Project Description: Project: Villa Cortina Elevator Replacement - Fire Alarm scope of work associated with adding elevator recall to Villa Cortina. Fees Paid Account #: 001-0000.31111.00 - Fire Scope Letter Fee Fee Amount:$216.00 Total Paid:$216.00 Conditions Issued By: Town of Vail Fire and Emergency Services Department NOTICE: By issuance of this Permit the applicant agrees to comply to all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. df-60379:A1 08/04/09 Page 1 of 2 CRF-300(A) Relay Module Addressable Devices df-60379:A1 E-400 General The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeed is a communication protocol developed by FireLite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED blinks green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01 159 for MS-9600(A) series panels, 01 99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 μA direct poll (CLIP mode), 255 μA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load DescriptionApplicationMaximum Voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5ms) Coded 30 VDC 0.5 A Inductive (L/R=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A CRF-300(A)60379cov.jpg Page 2 of 2 df-60379:A1 08/04/09 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact FireLite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com LiteSpeed is a trademark and FireLite® Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Made in the U.S. A. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA: 72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. : Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document I56-1190-005 and refer to the SLC Wiring Manual, document 51309. Before InstallIng This information is included as a quick reference installation guide. Refer to the control panel installation manual for detailed system information. If the modules will be installed in an existing operational system, inform the opera- tor and local authority that the system will be temporarily out of service. Dis- connect power to the control panel before installing the modules. NOTICE: This manual should be left with the owner/user of this equipment. general DescrIptIon The CRF-300 Relay Control Module is intended for use in addressable, two- wire systems, where the individual address of each module is selected using the built-in rotary switches. It allows a compatible control panel to switch discrete contacts by code command. The relay contains two isolated sets of Form-C contacts, which operate as a DPDT switch and are rated in accordance with the table in the manual. Circuit connections to the relay contacts are not supervised by the module. The module also has a panel controlled LED indicator. This module can be used to replace an C304 module that has been configured for Form-C operation. compatIBIlIty requIrements To ensure proper operation, these modules shall be connected to listed com- patible system control panels only. fIgure 1. controls anD InDIcators: C1071-00 specIfIcatIons Normal Operating Voltage: 15 to 32 VDC Maximum Current Draw: 6.5mA (LED on) Average Operating Current: 230 µA direct poll; 255 µA group poll EOL Resistance: Not used Temperature Range: 32°F to 120°F (0°C to 49°C) Humidity: 10% to 93% Non-condensing Dimensions: 41/2˝ H × 4˝ W × 11/4˝ D (Mounts to a 4˝ square by 21/8˝ deep box.) Accessories: SMB500 Electrical Box; CB500 Barrier crf-300 relay control module FL-460-001 1 I56-3651-002 I56-3651-002InstallatIon anD maIntenance InstructIons mountIng The CRF-300 mounts directly to 4-inch square electrical boxes (see Figure 2A). The box must have a minimum depth of 21/8 inches. Surface mounted electri- cal boxes (SMB500) are available. fIgure 2a. moDule mountIng fIgure 2B: wIth BarrIer: C1070-00 wIrIng NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. When using control modules in nonpower limited applications, the CB500 Module Barrier must be used to meet UL requirements for the sepa- ration of power-limited and nonpower-limited terminals and wiring. The bar- rier must be inserted into a 4˝×4˝×21/8˝ junction box, and the control module must be placed into the barrier and attached to the junction box (Figure 2A). The power-limited wiring must be placed into the isolated quadrant of the module barrier (Figure 2B). 1. Install module wiring in accordance with the job drawings and appropri- ate wiring diagrams. 2. Set the address on the module per job drawings. 3. Secure module to electrical box (supplied by installer), as shown in Figure 2A. One FireLite Place Northford, CT 06472 Phone: 203.484.7161 relay contact ratIngs: CURRENT RATING MAXIMUM VOLTAGE LOAD DESCRIPTION APPLICATION 3 A 30 VDC Resistive Non-coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-coded .9 A 125 VDC Resistive Non-coded .5 A 30 VDC Inductive (L/R=5ms) Coded 1 A 30 VDC Inductive (L/R=2ms) Coded .3 A 125 VAC Inductive (PF=.35) Non-coded 1.5 A 25 VAC Inductive (PF = .35) Non-coded .7 A 70.7 VAC Inductive (PF=.35) Non-coded 2 A 25 VAC Inductive (PF=.35) Non-coded WARNING All relay switch contacts are shipped in the standby state (open) state, but may have transferred to the activated (closed) state during shipping. To ensure that the switch contacts are in their correct state, modules must be made to communicate with the panel before connecting circuits controlled by the module. fIgure 3. relay moDule wIrIng DIagram: MODULE FROM PANEL ORTO NEXT DEVICE CONTROL CONNECT MODULES TO LISTED COMPATIBLE RELAY COMMON 1 RELAY COMMON 2 NORMALLY CLOSED 1 NORMALLY OPEN 2 NORMALLY CLOSED 2 MODULE DOES NOT SUPERVISE CONTROLLED CIRCUITS NORMALLY OPEN 1 CONTROL PANELS ONLY PREVIOUS DEVICE SIGNAL LINE CIRCUIT (SLC) 32 VDC MAX. TWISTED PAIR IS RECOMMENDED UNUSED *NOTE: ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE. IF ANY WIRING TO TERMINALS 4 10 IS NONPOWER LIMITED, THE CB500 BARRIER IS REQUIRED. THE CB500 INCLUDES A NONPOWER LIMITED LABEL, WHICH MUST BE PLACED OVER THE POWER LIMITED TERMINAL INFORMATION ON THE NAMEPLATE LABEL. C0924-04 FL-460-001 2 I56-3651-002 ©2008 Fire-Lite Alarms, Inc. PERMIT FEE RECEIPT Case # A18-0021 Date Printed: 04/30/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: A18-0021 Status: Created Permit Number: Date Started: 04/27/2018 Permit Type: Fire - Construction Permit Subcases Fire Alarm Lot Number: H Property: 22 W MEADOW DR (210107108999) (210107108999) Contacts Contact Type: Applicant Company Name: Xssentials Full Name: Karen Morgan Address: PO Box 534 730 Nottingham Road Avon, CO 81620 Email: karen.morgan@xssentials.com Contact Type: Property Owner Full Name: Common Area Address: Permit Fees Fee Information Account Amount Fire Scope Letter Fee 001-0000.31111.00 $216.00 Payment Information Date Paid Payment Type Amount Fire Scope Letter Fee 04/30/2018 Credit Card $216.00 Paid By: - Notes: mc-mary thul FEE TOTAL $216.00 AMOUNT PAID $216.00 BALANCE DUE $0.00 04/30/2018 - 12:17:27 PM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657 1 / 1