Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B18-0132_approved documents_1525378985.pdf
75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Construction B18-0132 Issued: 05/03/2018 TOWN OF VAIL Property Information Address: 1965 SUNBURST DR (210109103003) ( 210109103003 ) Unit #: Parcel Number: 210109103003 Legal Description: Subdivision: VAIL VALLEY 3RD FILING Lot: 11 R899269 DEC 12-01-04 Contacts Contact Type: Applicant Full Name: Chris Evans Address: PO Box 8266 77 Metcalf Road Avon, CO 81620 Phone: 9704715147 Contact Type: Property Owner Full Name: HANS G. STORR REVOCABLE TRUST Address: Phone: None Contractor Contractor Type: General Company: Evans Chaffee Construction Group State License #: 014348917 Phone: 970-845-0466 Project Information Project Name: Storr Residence 2018 Project Description: Renovation of interior & exterior finishes of single family home. Includes addition of 846 SF. New roofing, stucco, stone and exterior snow melt. Fees Paid Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$12,379.50 Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$8,046.68 Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$56,890.00 Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$2,420.00 Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$605.00 Account #: 001-0000.31111.00 - Plumbing Permit Fee Fee Amount:$810.00 Account #: 001-0000.31123.00 - Plumbing Plan Review Fee Fee Amount:$202.50 Account #: 111-0000.31127.00 - Recreation Amenities Fee Fee Amount:$126.90 Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Plumbing Scope)Fee Amount:$5.00 Total Paid:$81,495.58 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. Page 1 of 1 27 April 2018 Justin Lightfield Community Development Town of Vail 75 South Frontage Road Vail, Colorado 81657 RE: B18-0132_1965 Sunburst Drive– Building Permit Response Narrative Dear Justin, I wanted to provide a written recap of the minor modification changes proposed for this project and that we discussed on the phone yesterday. They are as follows: • A0.0: Updated to indicate occupancy, construction type and that an automatic fire suppression system is required. • A1.1: This sheet is resubmitted to match the Minor Modification Application. Grades have been changed to accommodate positive drainage away from the structure and to preserve the function of the existing drainage ditch. The ditch is slightly relocated to accommodate these goals. These grading changes impact the west building elevation. • A4.1: Updated to reflect the changes and match the Minor Modification. • A4.2: Updated to reflect the changes and match the Minor Modification. • A5.1: The note for the gas firepit has been modified to indicate the requirement for a 30 min automatic shutoff. Please let me know if I can answer any questions. Sincerely, Brian Sipes, AIA, LEED AP Sipes Architects A-PhaseElectric,LLC LOADCALCULATION WilsonResidence 1965SunburstDrive Vail,CO81657 GeneralLightingandReceptacleDemandLoad: 6000 sq.ft.x3VA= 18000 1,500VAx2= 3000 1,500VAx1= 1500 Totalconnectedload: 22,500 3,000VA@100%= 3,000 VA@35%= 6,825.0 2388.75 Totalgenerallightingand Receptacledemandload: 5,389 Rangedemandload: 8,000 DryerLoad: 5,000 Fixedapplianceload: Dishwasher 1200 2 2,400 Microwave 1800 1 1,800 Garbagedisposal 800 1 800 steamshower 5000 1 5000 other 0 0 0 other 0 0 0 other 0 0 0 other 0 0 0 other 0 0 0 other 0 0 0 Totalfixedapplianceload: 10,000 www.aphaseelectricllc.com A-PhaseElectric,LLC LOADCALCULATION WilsonResidence 1965SunburstDrive Vail,CO81657 Heatingload: Boiler 0.2 1 200 Pump 0.2 4 800 heattape 5 50 250 Totalheatingload: 1,250 25%oflargestmotor: 300 Totals: Generallightingandreceptacles: 5,389 Range: 8,000 Dryer: 5,000 Fixedappliance: 10,000 Heating: 1,250 25%oflargestmotor: 300 Total: VA 29,939 AMPS 143.94 InstalledServiceSize: 200Asinglephase x www.aphaseelectricllc.com LyteCaster L4R Downlight Spec 08/17 page 1 of 5 Project: Location: Cat.No: Type: Lamps: Qty: Notes: Trim Example: L4RDW Series L4R Luminaire type Finish L4R LyteCaster 4" Round D Open Downlight D Clear diffuse (with white flange) W White (with white flange) B Baffle Downlight W White (with white flange) 1. When ordering a Frame-in kit and a Light engine, the lumen package code must match. 2. Version A (VA) frames and light engines are not compatible with previous versions. Frame-In kit Example: L4R10AE1VA Series L4R Lumens 1 Frame type Dimming / Voltage Version VA L4R LyteCaster 4" Round — 650 lm 10 1000 lm A AirSeal IC, New Construction, Screw AN AirSeal IC, New Construction, Nail E1 ELV/Triac dimming with 120V Z10U 0-10V with Universal 120V/277V VA Version A 2 06 650 lm 10 1000 lm R AirSeal IC, Remodeler Light engine Example: L4R10930VA Series L4R Lumens 1 CRI / CCT Version VA L4R LyteCaster 4" Round 06 650 lm 10 1000 lm 827 80 CRI / 2700K CCT 830 80 CRI / 3000K CCT 835 80 CRI / 3500K CCT 840 80 CRI / 4000K CCT 927 90 CRI / 2700K CCT 930 90 CRI / 3000K CCT VA Version A 2 Note: Lumen output is calculated based on 80 CRI and 3500K CCT. Please consult adjustment factors table on page 5 for other lumen outputs. New construction Remodeler Downlighting LyteCaster 4" Round downlight Complete Product = Frame-in kit + Light engine + Trim (order each separately) Philips Lightolier LyteCaster LED Downlights are ideal general purpose downlighting solution, providing comfortable, quality light. Available in new construction and remodeler frame with interchangeable light engine that is offered in two lumen packages. The downlight is wet location listed and comes in 3 standard option. LyteCaster L4R Downlight Spec 08/17 page 2 of 5 8" (202mm) 8 1/4" (210mm) 13 1/2" (342mm) 11 5/8" (296mm) 13" Min. (330mm) 24" Max. (610mm) BOTTOM VIEW 1" (25mm) 3 3/8" (86mm) 11 1/2" (292mm) 4 3/8" (111mm) Cut out L4R LyteCaster 4" Round General purpose downlight Bottom view Side view New construction frame-in kit 1 13/16" (47mm) 3 1/2" (89mm) 5" (127mm)LIGHT MODULE Features 1. Housing: .026" galvanized steel. UL listed for direct contact with thermal insulation. Airseal® housing minimizes air leakage to less than 2 CFM at 1.57PSF (or 75PA), the International Energy Conservation Code, and Washington State Energy Code (Section 502.4). This reduces heat loss and condensation in ceiling. Access door for inspection of junction box. 2. Lower frame and top cover: .026" galvanized steel. Accommodates ceilings up to 1" (25mm) thick. 3/8" (9.5mm) deep integral lip with four notches at 90° apart to simplify alignment. Locks into position along length of mounting bars with locking screws. 3. Junction Box: 2.5" X 5 3/8" X 2" (27 cu. in) .032" galvanized steel. UL listed 90˚ supply conductors. Rated for branch circuit wiring supplying connected luminaires (daisy chaining). 4. Retaining clips: Permit easy and fast installation of light engine/trim. 5. Mounting bars: .059" galvanized steel. Bars pivot for easy attachment and wire-in below ceiling line. Bars extend to accommodate 16" (406mm) to 24" (610mm) O.C. joist spacing. Bars can accommodate 12" (305mm) O.C. joist spacing after a slight field modification (see Instruction sheet). Features integral self tapping phillips/square drive screws for secure attachment to wood or metal construction. Also available with integral nails. Attaches to T-bar ceilings without the need of accessories. Bars installed on shortest dimension of frame,but can be easily repositioned 90° from original position. 6. Ceiling cutout: 4 ⅜" (111mm). Electrical Lifetime: Expected lifetime 50,000 hours and backed by a 5-year warranty. (see Philips.com/warranties for details) Driver ELV /Triac: 120V, 50/60Hz. RoHS compliant, Class 2 power supply. Complies with FCC rules per Title 47 Part 15 (Class B) for EMI / RFI (conducted & radiated). Class A sound rating. 0-10V: 120/277V, 50/60Hz. RoHS compliant, Class 2 power supply. Complies with FCC rules per Title 47 Part 15 (Class A) for EMI / RFI (conducted & radiated). Class A sound rating. Recommended dimmers See LED-DIM Specification Sheet. Labels cULus Listed Type I.C., frames are suitable for damp location. Trims are cULus suitable for wet location (no shower lens unit required). Complies with Air Leakage. Energy Star certified. Downlight trim Light engine LyteCaster L4R Downlight Spec 08/17 page 3 of 5 11 1/8" (282mm) 4 57/64" (124mm) 3 5/8" (92mm) 5 3/8" (137mm) 1/2" (13mm) 2 3/4" (70mm) 4 3/8" (111mm) L4R LyteCaster 4" Round General purpose downlight Features 1. Housing: .032 Aluminum. UL listed for direct contact with thermal insulation. Integral retaining spring secures housing to ceilings up to 2" thick. Removable for access to junction box and ceiling plenum. 5 ½" maximum for use in 2" x 6" joist construction and shallow plenum applications. Airseal® housing minimizes air leakage to less than 2 CFM at 1.57PSF (or 75PA), which complies with the International Energy Conservation Code, and Washington State Energy Code (Section 502.4). This reduces heat loss and condensation in ceiling. 2. Junction Box: 2 ½" x 2 ½" x 4 ⅞" (29 cu in.) .031” galvanized steel. UL listed for 90°C supply conductors. Rated for branch circuit wiring supplying connected fixtures. 3. Retaining clips: Permit easy and fast installation of light engine/trim. 4. Ceiling cutout: 4 ⅜" (111mm). Electrical Lifetime: Expected lifetime 50,000 hours and backed by a 5-year warranty. (see Philips.com/warranties for details) Driver ELV /Triac: 120V, 50/60Hz. RoHS compliant, Class 2 power supply. Complies with FCC rules per Title 47 Part 15 (Class B) for EMI / RFI (conducted & radiated). Class A sound rating. 0-10V: 120/277V, 50/60Hz. RoHS compliant, Class 2 power supply. Complies with FCC rules per Title 47 Part 15 (Class A) for EMI / RFI (conducted & radiated). Class A sound rating. Recommended dimmers See LED-DIM Specification Sheet. Labels cULus Listed Type I.C., frames are suitable for damp location. Trims are cULus suitable for wet location (no shower lens unit required). Complies with Air Leakage. Energy Star certified. Bottom view Side view Side view Remodeler kit LyteCaster L4R Downlight Spec 08/17 page 4 of 5 Std 1 7 2 3 4 5 6 L4R LyteCaster 4" Round General purpose downlight Electrical specifications 1. Housing: (0.05”) thick powder coated aluminum provides integrated thermal management allowing for a low profile at less than 3-1/2” tall. 2. LED board: High efficiency mid-flux LED’s. 3. Mixing chamber: 98% reflective, highly diffuse film. 4. Diffusion lens: (0.06”) thick acrylic opal lens provides an even source of illumination. 5. Retaining ring: (0.04”) thick powder coated aluminum, secures module components. 6. Reflector: 30% glass reinforced injection molded polycarbonate is durable and provides a 70° cutoff to the source. 7. Retaining clips: 29 gauge Stainless Steel, allows tool-less installation of light engine to trim. Frame-in kit / Remodeler Lumens Input volts Input freq. Input current LED drive current Input power LED power THD factor Power factor L4RAE1VA / L4R06RE1VA 650 120V 50/60Hz 0.07A 220mA 7W 6W <20% >0.9 L4RAZ10UVA / L4R06RZ10UVA 650 120V 50/60Hz 0.07A 220mA 8W 6W <10% >0.9 277V 50/60Hz 0.04A 220mA 8W 5W <10% >0.9 L4R10AE1VA / L4R10RE1VA 1000 120V 50/60Hz 0.09A 220mA 11W 9W <20% >0.9 L4R10AZ10UVA / L4R10R10UVA 1000 120V 50/60Hz 0.14A 220mA 12W 9W <5% >0.96 277V 50/60Hz 0.06A 220mA 12W 9W <10% >0.96 Downlight trim kit LyteCaster L4R Downlight Spec 08/17 page 5 of 5 L4R LyteCaster 4" Round General purpose downlight © 2017 Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. philips.com/luminaires Philips Lighting North America Corporation 200 Franklin Square Drive, Somerset, NJ 08873 Tel. 855-486-2216 Philips Lighting Canada Ltd. 281 Hillmount Rd, Markham, ON, Canada L6C 2S3 Tel. 800-668-9008 Downlight, 650lm Engine, 96.1 lm/w Downlight, 1000lm Engine, 90.6 lm/w Candela Curve 75 150 225 300 Candela Curve 100 200 300 400 Frame: L4RAE1VA, L4RAZ10UVA, L4R06RE1VA, L4R06RZ10UVA Engine: L4R06835VA Trim: L4RDW Output lumens: Input watts : CRI: CCT 1: Spacing Crit.: 662.8 lms 6.9 W 80 min 3500K 1.2 Frame: L4R10AE1VA, L4R10AZ10UVA, L4R10RE1VA, L4R10RZ10UVA Engine: L4R10835VA Trim: L4RDW Output lumens: Input watts : CRI: CCT 1: Spacing Crit.: 941.7 lms 10.4 W 80 min 3500K 1.2 Zonal summary Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 229 364 581 663 34.5% 54.9% 87.6% 100.0% Zonal summary Zone Lumens %Luminaire 0-30 0-40 0-60 0-90 328 519 826 942 34.8% 55.1% 87.7% 100.0% Coefficients of utilization Ceiling 80% 70% 50% 30% 0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio0 1 2 3 4 5 6 7 8 9 10 119 110 101 93 86 80 74 69 64 60 57 119 106 94 84 75 68 62 56 52 48 44 119 102 88 77 67 60 53 48 44 40 37 119 99 83 71 61 54 47 42 38 35 32 116 104 92 82 74 67 61 55 51 47 44 116 97 82 70 61 53 47 42 38 34 31 111 100 89 80 72 65 59 54 50 46 43 111 94 80 69 60 53 47 42 38 34 31 106 96 86 77 69 63 57 53 48 45 42 106 91 78 68 59 52 46 42 38 34 31 100 87 75 65 56 50 44 39 36 32 29 Coefficients of utilization Ceiling 80% 70% 50% 30% 0% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal cavity method - Effective floor reflectance = 20%Room Cavity Ratio 0 1 2 3 4 5 6 7 8 9 10 119 110 101 93 86 80 74 69 64 60 57 119 106 94 84 75 68 62 56 52 48 44 119 102 88 77 67 60 53 48 44 40 37 119 99 83 71 61 54 48 42 38 35 32 116 104 92 82 74 67 61 56 51 47 44 116 97 82 70 61 53 47 42 38 35 32 111 100 89 80 72 65 59 54 50 46 43 111 94 80 69 60 53 47 42 38 34 31 106 96 86 77 69 63 57 53 49 45 42 106 92 78 68 59 52 47 42 38 34 31 100 87 75 65 57 50 44 40 36 32 30 Single unit data Height to lighted plane Initial center beam foot-candles Beam diameter (ft)* 5' 6' 7' 8' 9' 12 9 6 5 4 6.0' 7.2' 8.4' 9.6' 10.8' * Beam diameter is where foot-candles drop to 50% of maximum. Single unit data Height to lighted plane Initial center beam foot-candles Beam diameter (ft)* 5' 6' 7' 8' 9' 18 12 9 7 5 6.0' 7.2' 8.4' 9.6' 10.8' * Beam diameter is where foot-candles drop to 50% of maximum. Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq. ft. 5' 6' 7' 8' 9' 27.6 18.1 13.0 10.8 8.6 0.31 0.20 0.14 0.12 0.10 38' x 38' x 10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances Multiple unit data - RCR 2 Spacing on center Initial center beam foot-candles Watts per sq. ft. 5' 6' 7' 8' 9' 39.3 25.8 18.4 15.4 12.3 0.46 0.30 0.22 0.18 0.14 38' x 38' x 10' Room, Workplane 2.5' above floor, 80/50/20% Reflectances Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 307 303 297 289 275 258 241 216 191 162 132 103 74 49 33 24 15 6 0 29 81 119 135 125 92 50 25 7 Angle Mean CP Lumens 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 438 434 427 414 394 370 341 307 270 230 187 145 104 69 47 34 21 9 0 41 117 170 192 177 130 70 36 10 Efficacy: 96.1 lm/w Report 2: 659GFR Efficacy: 90.6 lm/w Report 2: 774GFR CRI and CCT adjustment factors 90CRI 2700K = 71% 90CRI 3000K = 81% 80CRI 2700K = 89% 80CRI 3000K = 97% 80CRI 3500K = 100% 80CRI 4000K = 102% CRI and CCT adjustment factors 90CRI 2700K = 71% 90CRI 3000K = 81% 80CRI 2700K = 89% 80CRI 3000K = 97% 80CRI 3500K = 100% 80CRI 4000K = 102% Reflector finish adjustment factors CL = 100% CC = 97% D = 88% W = 79% Reflector finish adjustment factors CL = 100% CC = 97% D = 88% W = 79% 1. Correlated Color Temperature within specs as defined in ANSI_NEMA_ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products. 2. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products.