Loading...
HomeMy WebLinkAboutB18-0181 approved plans.pdfr)/G~ J/L/6l(03cJ· (J. l '1 S--Uf fh'nofl >Y L/0~ C/ H I L8'I I F1f_8Yn l_ - Proposal -Detailed Pella Window and Door Showroom of Glenwood Springs 5317 Rd 154 204 Glenwood Springs, CO 81601 Phone: (970) 945-2289 Fax: (970) 945-4419 Sales Rep Name: Triebel, Michael Sales Rep Phone: (970) 945-2289 Sales Rep E-Mail: mtriebel@pellacolorado.com Sales Rep Fax: (970) 945-4419 Customer Information Project/Delivery Address Order Information HMR construction Jared Freml PO BOX2502 2195 Chamoniox 9A EDWARDS, CO 81632 Lot# Primary Phone: (970) 328-0581 VAIL, CO 81657 Mobile Phone: County: EAGLE Fax Number: (970) 9260250 Owner Name: E-Mail: hmrconst@aol.com Contact Name: Owner Phone: Great Plains#: 8403029 Customer Number: 1002826106 Customer Account 1000478143 Quote Name: Proline Order Number: 042 Quote Number: 10044247 Order Type: Non-Installed Sales Wall Depth: Payment Terms: Net30 Days Tax Code: llA Cust Delivery Date: None Quoted Date: 4/13/2018 Contracted Date: Booked Date: Customer PO I: fown of Vail REVIEWED FOR CODE COMPLIANCE Date: _ __.:..._r..._.:..' -l!!i~---- By: ___ r;.,~~---- Code: JS- For more infonmation regarding the finishing, maintenance, service and warranty of all Pella® products, visit the Pella® website at www.pella.com Printed on 4/1312018 Detailed Proposal Page 1 of 9 Customer: HMR construction ! Linet Loc:Mlon: 10 Living, Bed 1 'gJ2' ·. "'-... ;;; .. I · .... , =--ro-~ Viewed From Ex1erior PK# 2004 Rough Opening: 70 -314" X 62 -1/4" Project Name: Jared Freml Architect, 2-Wide Casement, 70 X 61.5, White 1: Non-Standard Size Left Casement Frame Size: 35 X 61112 General Information: Standard, Clad, Pine, 5", 3 11/16" Exterior Color I Finish: Painted, Standard Enduraclad, White Interior Color I Finish: Prefinished White Interior Sash I Panel: Ogee, Ogee, Standard Attributes Glass: Insulated Dual Tempered Low-E Advanced Low-E Insulating Glass Air Filled High Altitude Quote Number: 10044247 Item Price ~ Ext'd Price $1,866.03 2 $3,732.06 Hardware Options: Wash Hinge Hardware, Fold-Away Crank, White, No Window Opening Control Device, No Limited Opening Hardware, No Integrated Sensor ....... ,,..,,_..-----......, Screen: Full Screen, Whita w Performance lnformatlo • U-Factor 0.31, SHGC 0.26 T 0.48, CPD PEL-N-11-17169-00001, Performance Class CW, PG 50, Calculated Positive DP Rating 50, Calculated Nega D , ear a ed 08, Egress Meets Typical 5.7 sqfl (E) (United States Only) Grille: No Grille, Vertical Mull 1: FactoryMull, Standard Joining Mullion, Frame To Frame Width-O", Mull Design Pressure-20 2: Non-Standard Size Right Casement Frame Size: 35 X 61 112 General Information: Standard, Clad, Pine, 5", 3 11116" Exterior Color I Finish: Painted, Standard Enduraclad, White Interior Color I Finish: Prefinished White Interior Sash I Panel: Ogee, Ogee, Standard Glass: Insulated Dual Tempered Low-E Advanced Low-E Insulating Glass Air Filled High Altitude Hardware Options: Wash Hinge Hardware, Fold-Away Crank, White, No Window Opening Control Device, No Limited Opening Hardware, No Integrated Sensor ScrHn: Full Screen, White, lnVlew"' Perfomulnce Information: U-Factor 0.31, SHGC 0.26, VL T 0.48, CPD PEL-N-11-17169-00001, Performance Class CW, PG 50, Calculated Positive DP Rating 50, Calculated Negative DP Rating 50, Year Rated 08, Egress Meets Typical 5.7 aqfl (E) (United States Only) Grille: No Grille, Vertical Mull 1: FactoryMull, Standard Joining Mullion, Frame To Frame Width-O", Mull Design Pressure-20 Wrapping Information: Foldout Fins, Factory Applied, No Extertor Trim, 4 9/16", 5 718", Standard Four Sided Jamb Extension, Factory Applied, Pella Recommended Clearance, Perimeter Length = 263". For more information regarding the finishing, maintenance, service and warranty of all Pella® products, visit the Pella® website at www.pella.com Printed on 4/1312018 Detailed Proposal Page 2 of 9 Customer: HMR construction I Linet LOCltlon: 15 Bed 2 Viewed From Exterior PKI 2004 Rough Opening: 47 -314' X 50-314' Project Name: Jared Freml Architect, 2-Wide Casement, 47 X 50, White 1: Non-Standard Size Non-Standard Size Left Casement Frame Size: 23 1/2 X 50 General Information: Standard, Clad, Pine, 5", 3 11/16" Exterior Color I Finish: Painted, Standard Enduraclad, White Interior Color I Finish: Prefinished White Interior Sash I Panel: Ogee, Ogee, Standard Attributes Glass: Insulated Dual Low-E Advanced Low-E Insulating Glass Air Filled High Altitude Quote Number: 10044247 Item Price ~ Ext'd Price $1,570.41 $1 ,570.41 Hardware Options: Side Pivot Hardware, Fold-Away Crank, White, No Window Opening Control Device, No Limited Opening Hardware, No Integrated Sensor S er , , erformance Information: LI-Factor 0.31 , SH 0.26, Vl T 0.48, CPD PEL-N-11-17169-00001, Performance Class CW, PG 50, Calculated Positive DP · g , culat ega , ear Rated 08, Egress Does not meet typical United States egress, but may comply with local code requirements Grille: No Grille, Vertical Mull 1: FactoryMull, Standard Joining Mullion, Frame To Frame Width-O", Mull Design Pressure-20 2: Non-Standard SlzeNon-Standard Size Right Casement Frame Size: 23 112 X 50 General Information: Standard, Clad, Pine, 5", 311/16" Exterior Color I Finish: Painted, Standard Enduraclad, White Interior Color I Finish: Prefinished White Interior Sash I Panel: Ogee, Ogee, Standard Glass: Insulated Dual Low-E Advanced Low-E Insulating Glass Air Filled High Altitude Hardware Options: Side Pivot Hardware, Fold-Away Crank, White, No Window Opening Control Device, No Limited Opening Hardware, No Integrated Sensor Screen: Full Screen, White, lnView"' Performance Information: LI-Factor 0.31 , SHGC 0.26, Vl T 0.48, CPD PEL-N-11-17169-00001, Performance Clan CW, PG 50, Calculated Positive DP Rating 50, Calculated Negative DP Rating 50, Year Rated 08, Egress Does not meet typical United States egress, but may comply with local code requirements Grille: No Grille, Vertical Mull 1: FactoryMull, Standard Joining Mullion, Frame To Frame Width-O", Mull Design Pressure-20 Wrapping lnfonn•tion: Foldout Fins, Factory Applied, No Extertor Trim, 4 9/16", 5 7/8", Standard Four Sided Jamb Extension, Factory Applied, Pella Recommended Clearance, Pertmeter Length = 194". For more information regarding the finishing, maintenance, service and warranty of all Pella® products, visit the Pella® website at www.pella.com Printed on 4/1312018 Detailed Proposal Page 3 of 9 Account Account: R013408 Sketch by Ape~ Medinao 0 ('") 18.5' BAS 555.0 sf 18.5' 0 ('") 0 ('") WDB 16.0 sf ~Fl FUS 555.0 sf 18.5' 0 ('") Page 1 of 1 http:/ !property .eaglecounty. us/assessor/taxweb/account.j sp?accountNum=RO 13408&doc=SKETCH&ske... 0510412018 PINE RIDGE TOWNHOUSES ASSOCIATION ARCHITECTURAL CONTROL COMMITTEE (ACC) IMPROVEMENT REQUEST COMMUNITY MANAGEMENT SPECIALISTS, INC. 1224 Wadsworth Blvd, Lakewood, CO 80214 720/377-0100 * * 720/377-0111 Fax FOR OFFICE USE ONLY Date Received, ____ _ Critical Date ____ _ Date Sent to ACC ___ _ Date Received from ACC __ Rep. _______ _ Filing:Rne R1a\ce..-Block: fkDY/ I\\ Lot:____,_,9 ,.....__.,,...,...- J Home Phone: L/0(}.-;;</G -ZI 8%' CO Zip: 216'7? Work Phone: _______ _ Mailing address if different than proposed improvement(s)399?. S. C/oY-kSoV>.. S+. 1 DeY)\(Cc 1 CCJ 80209 My request involves the following type of improvement: D Satellite Dish {Satellite dishes cannot be installed on roofs. The preferred location Is on the patio/deck on a free standing pole.) o Air Conditioner D Patio/Deck Improvements or Changes ~Window Replacements D Front Door Replacement o Other ______________________ _ I understand that I must receive approval of the Architectural Control Committee or Board of Directors in order to proceed. I understand that AC approval does not constitute approval of the local building department and that I may be required to obtain a building permit. I agree to complete improvements promptly after receiving approval. I have read the instruction sheet and will comply. I also understand that I shall maintain proper drainage away from my foundation and not impede proper drainage swales on my lot when installing landscape or building improvements. Upon the completion of my improvement I hereby authorize the Architectural Committee and Community Management Specialists to enter onto my property for exterior inspection at a mutually agreed upon time. !_!_ Date: ~D \ I~,. fXO j ~ Homeowners Signature:_...,~~._/a...._ .... W?..._.:i_,.......___.::t ................... J ..... ~-------- AC ACTION: Xl Approved as Submitted. n Apprpved subject to the following requirements _______________________ _ CJ Disapproved:, __________________________________ _ Arehitectural Control Committee Member ___ ...,2_...! ......... :"-J--'-"t~-----------Date: __ 4_·_2_5_· _18 ____ _ PleaH remember to get any permits that may be required for your improvement from the City before construction begins.