HomeMy WebLinkAboutB18-0071_Approved Plans_1526315353.pdfScale:
Date:
*FIELD VERIFY
ALL DIM'S
3D VIEWS -
EXISTING
05/23/2017G O RE C REEK C O N D O M IN IU M S| EX TERIO R REM O D ELA0.05014 MAIN GORE DRIVE | VAIL, COLORADO, 81657
OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI1 3D VIEW (NW) - EXISTING 2 3D VIEW (NE) - EXISTING
3 3D VIEW (SW) - EXISTING 4 3D VIEW (SE) - EXISTING
No. Revisions Date
05/14/18
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
3D VIEWS -
PROPOSED
05/23/2017G O RE C REEK C O N D O M IN IU M S| EX TERIO R REM O D ELA0.0P5014 MAIN GORE DRIVE | VAIL, COLORADO, 81657
OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI1 3D VIEW (NE) - PROPOSED
2 3D VIEW (NW) - PROPOSED
3 3D VIEW (SE) - PROPOSED
4 3D VIEW (SW) - PROPOSED
No. Revisions Date
05/14/18
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
3D VIEWS -
PROPOSED (WEST,
AERIAL, & CLOSE
UP 3D VIEWS)
05/23/2017G O RE C REEK C O N D O M IN IU M S| EX TERIO R REM O D ELA0.1P5014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI4 FRONT DECK - CLOSE UP 1
6 REAR DECK - CLOSE UP 17REAR DECK - CLOSE UP 2
2 FRONT DECK - AERIAL 3D VIEW1REAR DECK - AERIAL 3D VIEW
3 3D VIEW (W) - PROPOSED
5 FRONT DECK - CLOSE UP 28REAR DECK - CLOSE UP 3
No. Revisions Date
05/14/18
N00° 00'00"E35.00'N90°00'00"W
87.00'S00° 00'00"E35.00'87.00'
165.00'
S 90°00'00" E
136.00'N 11° 18'36.00" E147.87'N 90°00'00"E
S
3
8
°9'4
3
2
8
TREE
C #1
TREE
C #2
TREE
C #3
TREE
C #4
TREE
C #6
TREE
C #5
TREE
D #1
TREE
D #2
TREE
D #3
TREE
D #4
FOUND 1-1/2"
DIAMETER ALUMINUM
CAP PLS 20695
ON A 5/8" DIAMETER
REBAR
8556.9
8557.8 GM GM G
M GMEMEM EXIST.
ASPHALT
PARKING
BUILDING D
5014 MAIN GORE DR.
(4-PLEX w/ 1
STORY+LOFT UNITS)
UP
UP
EXISTING
STAIRS
EXISTING
BEAR STATUE
UP 18.40'33.20'SETBACK15.00'SETBACK
15.00'SETBACK15.00'SETBACK
20.00'MAIN GORE DRIVE(50' R.O.W.)GORE CREEK MEADOWS
ABSORPTION FIELD
BLDG-E-AREA
0.262 ACRES
ABSORPTION FIELD
BLDG-B-AREA
ABSORPTION FIELD
BLDG-C-AREA
UNIT 1
UNIT 2
UNIT 4
UNIT 3
NATURAL
DRAINAGE DITCH
0.5' WIDE0.5' DEEP
1.0' WIDE
STONE WALL
EDGE OF LAWN
EXISTING
WOOD SHED
POWER POLE
OVERHEAD
ELECTRIC SERVICE
12' DIAMETER
CMP INLET
GORE CREEK MEADOWS
LOT 4
0.502 AC
GORE CREEK SUB
BLOCK 3
O HE
O HE
OHE
OH E
OHE
OH E
OH E
OH E
OH E
OH E
O HE
OHE
OHE
OH E
OH E
O H E
OHE
O HE
OHE
OH E
NATURAL
DRAINAGE DITCH
0.5' WIDE0.5' DEEP
54.10'
12' DIAMETER
CMP OUTLET
8559.7'
E XI STING
WOO D DE C K
EXISTING
STAIRS
EXISTING
SHED
E X IST ING WOO
D
DE CK
E XI S TING B EN C H
E
XI
STI
NG BE
NCHE XI S T ING BENCH EX
I
STI
NG BE
NCHE XI STING BEN CH EXIS
TI
NG BENCHEXIST. CONC.
STEPS & WALK
EXISTING CONC.SIDEWALK
F.F THRESHOLD
= 8565.0'
F.F THRESHOLD
= 8565.0'
F.F. THRESHOLD
= 8565.0'
F.F. THRESHOLD
= 8565.0'
8562.23'
T.O. DECK:8564.6'
T.O. DECK:
8564.7'
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
1" = 10'-0"
SITE PLAN -
EXISTING
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA0.25014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 1" = 10'-0"1 SITE PLAN - EXISTING
No. Revisions Date
05/14/18
N00° 00'00"E35.00'N90°00'00"W
87.00'S00° 00'00"E35.00'87.00'
165.00'
S 90°00'00" E
136.00'N 11° 18'36.00" E147.87'N 90°00'00"E
S
3
8
°
9
'
4
3
2
8
TREE
C #1
TREE
C #2
TREE
C #3
TREE
C #4
TREE
C #6
TREE
C #5
TREE
D #1
TREE
D #2
TREE
D #3
TREE
D #4
FOUND 1-1/2"
DIAMETER ALUMINUM
CAP PLS 20695
ON A 5/8" DIAMETER
REBAR
8556.9
8557.8
G
M GM GM G
MEMEM EXIST.
ASPHALT
PARKING
BUILDING D
5014 MAIN GORE DR.
(4-PLEX w/ 1
STORY+LOFT UNITS)
UP
UP
EXISTING
STAIRS
EXISTING
BEAR STATUE
UP 18.40'33.20'SETBACK15.00'SETBACK
15.00'SETBACK15.00'SETBACK
20.00'MAIN GORE DRIVE(50' R.O.W.)GORE CREEK MEADOWS
ABSORPTION FIELD
BLDG-E-AREA
0.262 ACRES
ABSORPTION FIELD
BLDG-B-AREA
ABSORPTION FIELD
BLDG-C-AREA
UNIT 1
UNIT 2
UNIT 4
UNIT 3
NATURAL
DRAINAGE DITCH
0.5' WIDE0.5' DEEP
1.0' WIDE
STONE WALL
EDGE OF LAWN
EXISTING
WOOD SHED
POWER POLE
OVERHEAD
ELECTRIC SERVICE
12' DIAMETER
CMP INLET
GORE CREEK MEADOWS
LOT 4
0.502 AC
GORE CREEK SUB
BLOCK 3
OH E
OH E
OH E
O HE
O H E
O HE
O HE
OHE
O HE
OHE
OH E
OH E
O H E
OHE
OHE
OHE
OH E
OH E
OH E
OHE
NATURAL
DRAINAGE DITCH
0.5' WIDE0.5' DEEP
54.10'
12' DIAMETER
CMP OUTLET
8559.7'
EXISTING
DECK
EXISTING
DECK
DEMO ENTIRE
DECK/RAILING/
STAIRS/BENCHES
DEMO ENTIRE
DECK/RAILING/ST
AIRS/BENCHES
DEMO EXIST.
SIDEWALK
DEMO EXIST.
SIDEWALK/STEPS
DEMO EXIST. SHED
(-12.5 SF)
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
1" = 10'-0"
SITE PLAN - DEMO
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA0.2D5014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 1" = 10'-0"1 SITE PLAN - DEMO
No. Revisions Date
05/14/18
N00° 00'00"E35.00'N90°00'00"W
87.00'S00° 00'00"E35.00'87.00'
165.00'
S 90°00'00" E
136.00'N 11° 18'36.00" E147.87'N 90°00'00"E
S 3
8
°
9'
4
3
2
8
TREE
C #1
TREE
C #2
TREE
C #3
TREE
C #4
TREE
C #6
TREE
C #5
TREE
D #1
TREE
D #2
TREE
D #3
TREE
D #4
FOUND 1-1/2"
DIAMETER ALUMINUM
CAP PLS 20695
ON A 5/8" DIAMETER
REBAR
8556.9
GM GM GM GME
MEM 18.40'33.20'SETBACK15.00'SETBACK
15.00'SETBACK15.00'SETBACK
20.00'
EXISTING
WOOD SHED
54.10'
EXIST.
ASPHALT
PARKING
BUILDING D
5014 MAIN GORE DR.
(4-PLEX w/ 1
STORY+LOFT UNITS)
NEWBEAR
STATUE MAIN GORE DRIVE(50' R.O.W.)GORE CREEK MEADOWS
ABSORPTION FIELD
BLDG-E-AREA
0.262 ACRES
ABSORPTION FIELD
BLDG-B-AREA
ABSORPTION FIELD
BLDG-C-AREA
UNIT 1
UNIT 2
UNIT 4
UNIT 3
NATURAL
DRAINAGE DITCH
0.5' WIDE0.5' DEEP
1.0' WIDE
STONE WALL
EDGE OF LAWN
POWER POLE
OVERHEAD
ELECTRIC SERVICE
12' DIAMETER
CMP INLET
GORE CREEK MEADOWS
LOT 4
0.502 AC
GORE CREEK SUB
BLOCK 3
O HE
OH E
OH E
OH E
OH E
OH E
O H E
O HE
O H E
O HE
O HE
OHE
OH E
OH E
OH E
O HE
OHE
OHE
OH E
OH E
NATURAL
DRAINAGE DITCH
0.5' WIDE0.5' DEEP
12' DIAMETER
CMP OUTLET
8559.7'
NEWSTAIRS
N E W W O O D or T R E X DEC K
F.F THRESHOLD
= 8565.0'
F.F. THRESHOLD
= 8565.0'
F.F. THRESHOLD
= 8565.0'
T.O. MAINDECK:8564.6'
T.O. MAIN DECK:8564.7'
NEW CONC.SIDEWALK
NEW CONC.SIDEWALK
NEWSTAIRS
T.O. LWR. DECK:8563.64'
T.O. UPPERDECK:8565.68'
T.O. UPPERDECK:8565.68'
FIRE PIT
NEW DININGPLATFORM(RAISED 13" FROM
MAIN DECK)
DN BUILT-IN BENCHNE W W O O D or T R E X DE C K
UP
NEW DINING PLATFORM
(RAISED 13" FROMMAIN DECK)
N E W WOOD
or T R E X D E C K
PLANTERS
GRI LLUP NEW
STAIRS
CONCRETE WEDGE(TO DIVERT WATER
AWAY FROM BLDG.)
NEW UTILITY SHED FORELECTRICAL METERS
(SHINGLE SIDING TO
MATCH DORMERS)NEW DININGPLATFORM
(RAISED 13" FROM
MAIN DECK)
NEW DINING PLATFORM(RAISED 13" FROMMAIN DECK)
STONE WALL UNDER THISDINING DECK ONLY
(TO HIDE AREA UNDERDECK/STRUCTURE)
BUI LT -IN BEN CH REMOVABLE PLANTER(w/ HOOK -ON OR OTHERTEMPORARY ATTACHMENT)NEW STONE WALLBUMP-OUTS
(+/- 10" THICK)
NEW STONE WALL
BUMP-OUTS(+/- 10" THICK)
REMOVABLE PLANTER
(w/ HOOK -ON OR OTHER
TEMPORARY ATTACHMENT)REMOVABLE PLANTER
(w/ HOOK -ON OR OTHER
TEMPORARY ATTACHMENT)NEW STONE WALL
BUMP-OUTS(+/- 10" THICK)
NEW STONE WALLBUMP-OUTS(+/- 10" THICK)
NEW TRASH SHED #1
(+33.5 SF)
NEW TRASH SHED #2
(+34.5 SF)
21.05' 15.30'
22.64'
16.
21'
NEW LO WER W OOD o r TRE X D EC K
NEW UTILITY
ENCLOSURE
(+7 SF)
NE W W O O D or T R E X DECK
SUNKEN HOT TUB(w/ GRADE LEVELSLAB BENEATH)
PLANTERSBUILT-IN B
EN
C
H
RE
MOVA
BLE PLA
NTE
R(w/ H
OOK -ON OR OT
HER
TE
MPO
RARY AT
TA
CH
MENT)
BUI LT -IN BENCH
REMOVABLE PLANTER
(w/ HOOK -ON OR OTHER
TEMPORARY ATTACHMENT)REMOVABLE PLANTER
(w/ HOOK -ON OR OTHER
TEMPORARY ATTACHMENT)
DN
UP
LOWER DECK(11.5" LOWER THAN
MAIN DECK)
T.O. UPPER DECK:8565.78'
T.O. UPPER DECK:8565.78'
UP
NEW SHED
(FOR TRASH &SKI STORAGE)
F.F THRESHOLD= 8565.0'
NEW SHED(FOR TRASH &
SKI STORAGE)
MAINTENANCE
HATCH
(32"x32",MAX)*VERIFY
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
1" = 10'-0"
SITE PLAN -
PROPOSED
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA0.2P5014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 1" = 10'-0"1 SITE PLAN - PROPOSED
No. Revisions Date
05/14/18
L
1
N00° 00'00"E35.00'N90°00'00"W
87.00'S00°00'00"E35.00'87.00'
136.00' 147.87'N 90°00'00"E S 3
8°9'4
5" E
3
2
8
.
5
4'
TREE
C #6
TREE
D #2
FOUND 1-1/2"
DIAMETER ALUMINUM
CAP PLS 20695
ON A 5/8" DIAMETER
REBAR
PROJECT BENCHMARK
TOP OF ALUMINUM CAP
ELEVATION =8571.71
FOUND 1-1/2"
DIAMETER PLASTIC CAP
PLS 2183 ON A 5/8"
DIAMETER REBAR IN PLACE
FOR THE SOUTHERLY COMMON
CORNER FOR LOTS 4 & 5
GORE CREEK SUBDIVISION N00° 00'00"E35.00'N90°00'00"W
87.00'S00°00'00"E35.00'87.00'
136.00'147.87'N 90°00'00"E
S 3
8°
9'4
3
2
TREE
C #6
TREE
D #2
FOUND 1-1/2"
DIAMETER ALUMINUM
CAP PLS 20695
ON A 5/8" DIAMETER
REBAR
EXIST. WOOD
SHED
COVERAGE(124 SF)
EXISTING BUILDING
COVERAGE(2,213 SF)
EXISTING F R ON T DECK COV ERAGE
(45 4 SF )
EXISTIN G REAR DE CK COV ERAGE
(467 SF)
EXISTING REAR SIDEWALK COVERAGE
(341 SF)
EXIST. FRONT SIDEWALK COVERAGE(114 SF)
EXISTING PARKINGCOVERAGE
(*AREA WITHIN PROPERTYLINES ONLY)
(1,345 SF)
TOTAL SITE AREA:
EXIST. APARTMENT BUILDING COVERAGE:
EXIST. FRONT DECK COVERAGE:
EXIST. REAR DECK COVERAGE:
EXIST. WOOD SHED COVERAGE:
*TOTAL EXISTING SITE COVERAGE:
3,258 SF/24,661 SF = .1321
*TOTAL EXISTING SITE COVERAGE (%):
24,661 SF
2,213 SF
454 SF
467 SF
124 SF
3,258 SF
13.21%
TOTAL SITE AREA:
TOTAL EXIST. SITE COVERAGE:
*TOTAL EXIST. LANDSCAPED AREA:
EXIST. PARKING COVERAGE (WITHIN PROPERTY LINES):
EXIST. FRONT SIDEWALK COVERAGE:
EXIST. REAR SIDEWALK COVERAGE:
EXIST. STONE WALL COVERAGE:
*TOTAL EXIST. HARDSCAPED AREA:
*TOTAL EXIST. SOFTSCAPED AREA:
24,661 SF
- 3,258 SF
21,403 SF
1,345 SF
114 SF
341 SF
50 SF
1,850 SF
21,403 SF
- 1,850 SF
19,653 SF
*EXISTING SITE COVERAGE: SF *EXISTING LANDSCAPED AREA (HARD vs. SOFT): SF
EXIST. STONE WALLCOVERAGE
(50 SF)
BUILDING COVERAGE
LEGEND:
DECK/PORCH COVERAGE
HARDSCAPING
SOFTSCAPING
EXIST. WOOD
SHED
COVERAGE(124 SF)
PROPOSED BUILDING
COVERAGE(2,319 SF)
PRO P OSE D F RON T DE CK COV ERAGE
(621 SF)
PRO P OS E D REA R D E CK COVERAGE
(1 ,3 19 SF)
PROPOSED REAR SIDEWALK COVERAGE(193 SF)
PROPOSED FRONT SIDEWALK COVERAGE
(151 SF)
EXISTING PARKINGCOVERAGE
(*AREA WITHIN PROPERTYLINES ONLY)
(1,345 SF)
TOTAL SITE AREA:
PROPOSED APARTMENT BUILDING COVERAGE:
PROPOSED FRONT DECK COVERAGE:
PROPOSED REAR DECK COVERAGE:
EXIST. WOOD SHED COVERAGE:
*TOTAL PROPOSED SITE COVERAGE:
4,384 SF/24,661 SF = .1777
*TOTAL PROPOSED SITE COVERAGE (%):
24,661 SF
2,319 SF
622 SF
1,319 SF
124 SF
4,384 SF
17.77%
TOTAL SITE AREA:
TOTAL PROPOSED SITE COVERAGE:
*TOTAL PROPOSED LANDSCAPED AREA:
EXIST. PARKING AREA (WITHIN PROPERTY LINES):
EXIST. STONE WALL AREA:
PROPOSED FRONT SIDEWALK AREA:
PROPOSED REAR SIDEWALK AREA:
*TOTAL PROPOSED HARDSCAPED AREA:
*TOTAL PROPOSED SOFTSCAPED AREA:
24,661 SF
-4,384 SF
20,277 SF
1,345 SF
50 SF
151 SF
193 SF
1,739 SF
20,277 SF
- 1,739 SF
18,538 SF
*PROPOSED SITE COVERAGE: SF SF
EXIST. STONE WALLCOVERAGE
(50 SF)
*PROPOSED LANDSCAPED AREA (HARD vs. SOFT):
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
1/16" = 1'-0"
SITE ANALYSES
(EXISTING vs.
PROPOSED)
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA0.35014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 1/16" = 1'-0"1 SITE ANALYSIS (EXISTING)
1/16" = 1'-0"2 SITE ANALYSIS (PROPOSED)
No. Revisions Date
05/14/18
EMEM5'-1 3/4" 3'-0" 6'-6 3/4" 3'-2 3/4"
6"
1'-4 3/4"
1'-4"
6'-1"
1'-5 1/2"1'-4 3/4"
6" 3'-1 1/2" 6'-10" 3'-1" 5'-1 3/4"
7 1/4"48'-9 1/2"
7 1/4"
EXISTING DECK = 50'-0" WIDE
5'-2 3/4" 3'-0" 6'-8 3/4" 3'-0"
5 1/2"
1'-5" 9'-3"
1'-4 3/4"
4 1/2" 3'-0" 7'-0" 2'-11" 5'-0 1/4"
9 3/4" 48'-6"8 1/4"
2'-3 63/128" 17'-1 1/128" EXISTING STAIRS = 9'-9" WIDE 17'-1 1/128" 2'-3 63/128"
19'-4 1/2" EXISTING STAIRS = 9'-9" WIDE 17'-1 1/128" 2'-3 63/128"
9 3/4"
EXISTING DECK = 48'-6" WIDE
8 1/4"
7 1/4"
48'-9 1/2"
7 1/4"2'-3 247/256" 6'-1 137/256" 44'-0" 6'-2 1/128" 2'-3 63/128"5'-0" 1'-0"5'-0" EXISTING DECK = 8'-5 1/2" DEEP 44'-0" EXISTING DECK = 8'-5 1/2" DEEP 1'-0"5'-0" EXISTING DECK = 8'-5 1/2" DEEP 44'-0" EXISTING DECK = 8'-5 1/2" DEEP 5'-0" 2'-3 63/128" 6'-2 1/128" 44'-0" 6'-1 137/256" 2'-3 247/256"EXIST. SHED
UNIT 1
UNIT 4
UNIT 2
UNIT 35'-0 1/4"3'-1" 5'-3 1/2" 5'-4" 5'-4 1/2" 5'-4" 5'-3 1/2" 3'-0" 5'-0 3/4" 7 1/4"7 1/4" 7 1/4"5'-0 1/4"3'-1" 5'-3 1/2" 5'-4" 5'-4 1/2" 5'-4" 5'-3 1/2" 3'-0" 5'-0 3/4" 7 1/4"2'-0 1/2"13 3/4"14 1/4"15 1/4"13 1/2" 15 3/4"13 1/2"
EXISTING BENCH
EXISTING BENCHEXISTING BENCH EXISTING BENCH EXISTING BENCH EXISTING BENCH12" 12" 12" 12" 12"12" 12" 12" 12" 12" 12"EXIST.
WOOD STAIRS
EXIST.
CONC. STEP
EXIST.
WOOD STAIRS
3 1 2 2 1 1
9
8
7
6
12 2 13 14 2 15
6
7
8
9
EXIST.
WOOD DECK
EXIST.
WOOD DECK
EXISTING
BEAR STATUE
6'-2 1/128"Scale:
Date:
*FIELD VERIFY
ALL DIM'S
1/4" = 1'-0"
1ST FLOOR PLAN -
EXISTING
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA1.05014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 1/4" = 1'-0"1 1ST FLOOR PLAN - EXISTING
No. Revisions Date
05/14/18
EMEM5'-1 3/4" 3'-0" 6'-6 3/4" 3'-2 3/4"
6"
1'-4 3/4"
1'-4"
6'-1"
1'-5 1/2"1'-4 3/4"
6" 3'-1 1/2" 6'-10" 3'-1" 5'-1 3/4"
7 1/4"48'-9 1/2"
7 1/4"
EXISTING DECK = 50'-0" WIDE
5'-2 3/4" 3'-0" 6'-8 3/4" 3'-0"
5 1/2"
1'-5" 9'-3"
1'-4 3/4"
4 1/2" 3'-0" 7'-0" 2'-11" 5'-0 1/4"
9 3/4" 48'-6"8 1/4"
2'-3 63/128" 17'-1 1/128" EXISTING STAIRS = 9'-9" WIDE 17'-1 1/128" 2'-3 63/128"
19'-4 1/2" EXISTING STAIRS = 9'-9" WIDE 17'-1 1/128" 2'-3 63/128"
9 3/4"
EXISTING DECK = 48'-6" WIDE
8 1/4"
7 1/4"
48'-9 1/2"
7 1/4"2'-3 247/256" 6'-1 137/256" 44'-0" 6'-2 1/128" 2'-3 63/128"5'-0" 1'-0"5'-0" EXISTING DECK = 8'-5 1/2" DEEP 44'-0" EXISTING DECK = 8'-5 1/2" DEEP 1'-0"5'-0" EXISTING DECK = 8'-5 1/2" DEEP 44'-0" EXISTING DECK = 8'-5 1/2" DEEP 5'-0" 2'-3 63/128" 6'-2 1/128" 44'-0" 6'-1 137/256" 2'-3 247/256"EXIST. SHED
UNIT 1
UNIT 4
UNIT 2
UNIT 35'-0 1/4"3'-1" 5'-3 1/2" 5'-4" 5'-4 1/2" 5'-4" 5'-3 1/2" 3'-0" 5'-0 3/4" 7 1/4"7 1/4" 7 1/4"5'-0 1/4"3'-1" 5'-3 1/2" 5'-4" 5'-4 1/2" 5'-4" 5'-3 1/2" 3'-0" 5'-0 3/4" 7 1/4"2'-0 1/2"13 3/4"14 1/4"15 1/4"13 1/2" 15 3/4"13 1/2"
EXISTING BENCH
EXISTING BENCHEXISTING BENCH EXISTING BENCH EXISTING BENCH EXISTING BENCH12" 12" 12" 12" 12"12" 12" 12" 12" 12" 12"EXIST.
WOOD STAIRS
EXIST.
CONC. STEP
EXIST.
WOOD STAIRS
3 1 2 2 1 1
9
8
7
6
12 2 13 14 2 15
6
7
8
9
EXIST.
WOOD DECK
EXIST.
WOOD DECK
DEMO ENTIRE
DECK/RAILING/STAIRS/
BENCHES/SHED
DEMO ENTIRE
DECK/RAILING/
STAIRS/BENCHES
REPLACE &
RELOCATE EXISTING
BEAR STATUE
DEMO EXIST. SHED
(-12.5 SF)
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
1/4" = 1'-0"
1ST FLOOR PLAN -
DEMO
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA1.0D5014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 1/4" = 1'-0"1 1ST FLOOR PLAN - DEMO
No. Revisions Date
05/14/18
GM GM GM GMEM EMUP
UPUP
5'-1 3/4" 3'-0" 6'-6 3/4" 3'-2 3/4"
6"
1'-4 3/4"
1'-4 3/4"
6" 3'-1 1/2" 6'-10" 3'-1" 5'-1 3/4"
7 1/4"48'-9 1/2"
7 1/4"
50'-0"
5'-2 3/4" 3'-0" 6'-8 3/4" 3'-0"
5 1/2"
1'-5" 9'-3"
1'-4 3/4"
4 1/2" 3'-0" 7'-0" 2'-11" 5'-0 1/4"
7 1/4"
48'-9 1/2"7 1/4"44'-0" 44'-0" UNIT 1
UNIT 4
UNIT 2
UNIT 35'-0 1/4" 3'-1" 5'-3 1/2" 5'-4" 5'-4 1/2" 5'-4" 5'-3 1/2" 3'-0" 5'-0 3/4" 7 1/4"7 1/4" 7 1/4"5'-0 1/4"3'-1" 5'-3 1/2" 5'-4" 5'-4 1/2" 5'-4"5'-3 1/2" 3'-0" 5'-0 3/4" 7 1/4"3 1 2 2 1 1
9
8
7
6
12 2 13 14 2 15
6
7
8
9
8'-10 1/2"
50'-0"10" NEW
STAIRS
NEW SHED
(FOR TRASH &
SKI STORAGE)
FIRE PIT
GRILL
STONE WALL UNDER THIS
DINING DECK ONLY
(TO HIDE AREA UNDER
DECK/STRUCTURE)
NEW DINING PLATFORM
(SOUTH DECK)
(RAISED 13" FROM MAIN
DECK, 12FT x 10FT)
NEW WOOD or TREX DECK
PLANTERS
(15"D x 36"T)BUILT-IN BENCHSUNKEN HOT TUB
(w/ GRADE LEVEL
SLAB BENEATH)
NEW
STAIRS
REMOVABLE PLANTER
(w/ HOOK -ON OR OTHER
TEMPORARY ATTACHMENT)
NEW WOOD or TREX DECK
CONCRETE WEDGE
(TO DIVERT WATER
AWAY FROM BLDG.)
NEW UTILITY SHED FOR
ELECTRICAL METERS
(SHAKE SIDING TO
MATCH DORMERS)
NEW
CONCRETE
WALK
NEW CONCRETE
WALK
NEW STAIRS
UP UPREMOVABLE PLANTER(w/ HOOK -ON OR OTHERTEMPORARY ATTACHMENT)UP
NEW STONE WALL
BUMP-OUTS
(+/- 10" THICK)75"
NEW STONE WALL
BUMP-OUTS
(+/- 10" THICK)
NEW STONE WALL
BUMP-OUTS
(+/- 10" THICK)
NEW STONE WALL
BUMP-OUTS
(+/- 10" THICK)
2
A1.0P
NEW TRASH SHED #1
(+33.5 SF)
NEW TRASH SHED #2
(+34.5 SF)
NEW UTILITY
ENCLOSURE
(+7 SF)48"75"10" 11 1/2"OPEN
(NO RAILING HERE)10" 10"7'-3 1/2" 16'-5" 23'-8 1/2"10" 10"10"NEW WOOD or TREX DECK
NEW WOOD or TREX DECK
NEW LOWER
COMMUNAL DECK
(11 1/2" LOWER THAN MAIN
DECK, WOOD or TREX)4'-1 1/2" 10'-0"4'-5 1/2" 10'-0" 4'-11 1/2" 8'-0" 4'-11 1/2" 6'-9"
NEW DINING PLATFORM
(NORTH DECK)
(RAISED 13" FROM MAIN
DECK, 10FT x 10FT)
7'-1" 18"3 1/2"3/4"4'-10 1/2" 10'-0" 2'-9 1/2" 5'-3" 9 1/2" 23'-8 1/2" 1'-0"1'-0" 1'-0" 12"12" 12" 12"12" 12" 12" 3 1/2"+/- 8'-7"
INSET RAIL 1/2" FROM INSIDE FACE OF RIM
(*PER MANUF. SPEC.)
1 1/2"3 1/2" TOP RAILS/POSTS
NEW DINING
PLATFORM
(SOUTH DECK)
(RAISED 13" FROM
MAIN DECK,
12FT x 10FT)
NEW DINING
PLATFORM
(NORTH DECK)
(RAISED 13" FROM
MAIN DECK,
10FT x 10FT)
*TYPICAL RAILINGS
(FORTRESSVERTICAL CABLE RAILING SYSTEM,"
34"T x 69.5"L & 93.5"L PRE-FAB. PANELS w/ 1/8"Ø
VERT. STEEL CABLES @ 3 1/4"O.C. & ONE 5/8"Ø
VERT. CENTER SUPPORT PER PANEL, ADD 4x4
CEDAR POSTS & 2x4 CEDAR TOP RAILS,
FINISHED RAILING HEIGHT: 3'-3 1/4",
INSET RAILING 1/2" FROM INSIDE FACE OF RIM
JOIST PER MANUF. SPEC.)
REMOVABLE PLANTER
(w/ HOOK -ON OR OTHER
TEMPORARY ATTACHMENT)
1 1/2" RIM JOIST
INSET RAIL 1/2" FROM INSIDE FACE OF RIM
(*PER MANUF. SPEC.)
OFFSET 2"
*TYPICAL RAILINGS
(FORTRESSVERTICAL CABLE RAILING SYSTEM,"
34"T x 69.5"L & 93.5"L PRE-FAB. PANELS w/ 1/8"Ø
VERT. STEEL CABLES @ 3 1/4"O.C. & ONE 5/8"Ø
VERT. CENTER SUPPORT PER PANEL, ADD 4x4
CEDAR POSTS & 2x4 CEDAR TOP RAILS,
FINISHED RAILING HEIGHT: 3'-3 1/4",
INSET RAILING 1/2" FROM INSIDE FACE OF RIM
JOIST PER MANUF. SPEC.)
BUILT-IN BENCH
UP
DNDN 2'-6 91/256"2'-6
91/256" BUILT-IN BENCH15" 15"
TO HOT TUB
42"
100"L HOT TUB TO HOT TUB
36" 88" 82" 66" 30" 15" 15"
12" 12"36"91"W HOT TUB TO HOT TUB36 1/2" 70 1/2" 66" 49" 1'-3" 1'-3"15" 15"
3'-9 19/128" 34'-5 181/256" 3'-9 19/128"
12'-0" 42'-0" 12'-0"
PLANTERS
(15"D x 36"T)
3'-1"
4'-11 1/2" 8'-0"
REMOVABLE PLANTER
(w/ HOOK -ON OR OTHER
TEMPORARY ATTACHMENT)
U
P
REMOVABLE PLANTER(w/ HOOK -ON OR OTHERTEMPORARY ATTACHMENT)REMOVABLE PLANTER
(w/ HOOK -ON OR OTHER
TEMPORARY ATTACHMENT)
3
A1.0P
4'-11 1/2" 10'-0"
62'-7"10'-0"4'-5 1/2" *SLAT RAILINGS(BEHIND HANGING PLANTERSON NORTH DECK, 1x2 HORIZ. SLATS,EVENLY SPACED, *SEE DETAIL)
HATCH/OPENING
(32" x 32" (MAX)
*VERIFY
GAP TO DECKING:
+/- 1/2" (*VERIFY)36"3'-5 1/2"1/2"11 1/2"1" OVHG64"1" OVHG OVHG
1"
64"OVHG
1"57 1/2" 101"TO HOT TUB30"
15" 15
"
TO
HO
T
TUB30"12"4"48"48"76" 4" 4" 73 1/2"48"12"3'-1"11 1/2"NEW EXTERIOR
LIGHT 18"NEW EXTERIOR
LIGHT
NEW EXTERIOR
LIGHT
NEW EXTERIOR
LIGHT 8'-5 1/2" 12"
18"
18"18"*SLAT RAILINGS(BEHIND HANGING PLANTERSON NORTH DECK, 1x2 HORIZ. SLATS,EVENLY SPACED, *SEE DETAIL)
*SLAT RAILINGS(BEHIND HANGING PLANTERSON NORTH DECK, 1x2 HORIZ. SLATS,EVENLY SPACED, *SEE DETAIL)
*SLAT RAILINGS(BEHIND HANGING PLANTERSON NORTH DECK, 1x2 HORIZ. SLATS,EVENLY SPACED, *SEE DETAIL)
7'-1"
4" TO HOT TUB 58" 1/2" GAP (*VERIFY)1/2" GAP (*VERIFY)*VERIFY UPPER DECK STAIRLOCATION FOR HATCHSIZING/CLEARANCE
GAP TO DECKING:
+/- 1/2" (*VERIFY)92" +/- 4'-0" TO EXIST. WALL*CENTER SHEDS BETWEENADJACENT WINDOWS.
*VERIFY CLEARANCE BETWEEN
NEW WINDOW TRIM.
*VERIFY REQ'D TRASH CANCLEARANCE.+/- 4'-0" TO EXIST. WALL 4'-6 1/2"+/- 8'-3 1/2"
NEW SHED
(FOR TRASH &
SKI STORAGE)
*CENTER SHED BETWEEN
ADJACENT WINDOWS.
*VERIFY CLEARANCEBETWEEN NEW WINDOWTRIM.
*VERIFY REQ'DEQUIPMENT CLEARANCE.
*CENTER SHEDS BETWEENADJACENT WINDOWS.
*VERIFY CLEARANCE BETWEENNEW WINDOW TRIM.
*VERIFY REQ'D TRASH CAN
CLEARANCE.
CEDAR TOP RAILS
(1 1/2"T x 3 1/2"W)
*TYPICAL RAILINGS
(FORTRESSVERTICALCABLE RAILING SYSTEM,"
34"T x 69.5"L & 93.5"L PRE-
FAB. PANELS w/ 1/8"ØVERT. STEEL CABLES @ 3
1/4"O.C. & ONE 5/8"Ø
VERT. CENTER SUPPORT PER
PANEL, ADD 4x4 CEDAR
POSTS & 2x4 CEDAR TOP
RAILS, FINISHED RAILING
HEIGHT: 3'-3 1/4",INSET RAILING 1/2" FROM
INSIDE FACE OF RIM JOIST
PER MANUF. SPEC.)
4x4 CEDAR POSTS
(3 1/2" x 3 1/2")
3 1/4" O.C. 3 1/4" O.C.3 3/4" 2'-10"T PRE-FAB PANELSFLAT TOP RAIL1 1/2" x 3 1/2"RAILING HEIGHT: 3'-3 1/4"CHANNEL1 1/4" x 1 1/4"2'-7 1/2"CHANNEL1 1/4" x 1 1/4"3'-3 1/4"1x2 HORIZ. SLATS:2"T x 3/4" THICK (EVENLY SPACED)3'-1 3/4"(TO MATCH OTHER RAILS)1 1/2" x 3 1/2" FLAT TOP RAILCEDAR TOP RAILS
(1 1/2"T x 3 1/2"W, TO
MATCH OTHER RAILS)
*SLAT RAILINGS
(BEHIND HANGING PLANTERS
ON NORTH DECK,
1x2 HORIZ. SLATS, EVENLY SPACED)
4x4 CEDAR POSTS
(3 1/2" x 3 1/2", TO
MATCH OTHER RAILS)
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
As indicated
1ST FLOOR PLAN -
PROPOSED
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA1.0P5014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 1/4" = 1'-0" 1 1ST FLOOR PLAN - PROPOSED
1/2" = 1'-0"2 RAILING DETAIL - FORTRESS VERTICAL CABLE RAILING SYSTEM
1/2" = 1'-0"3 RAILING DETAIL - SLAT RAILING @ NORTH PLANTERS
No. Revisions Date
30 minute
automatic shutoff
Nelson Electric Permit
970-390-6812
See permit app in system
Gas piping for grill and fire pit
will connect to existing meter from unit # 3
Eagle Valley - Roger D. Villeda 970-977-0567
3/4" Black iron gas pipe will be wrapped with 20mill PVC tape
for underground run of the steep pipe
NEC 680.26(7) Noted
05/14/18
11
10
5 5
11
10
1617 17 16
4 47 1/4"14'-1 1/2" 3'-10 1/2" 6'-10" 3'-10 1/2" 14'-1"7 1/4" 44'-0"EXIST. FAUX
BALCONY
UNIT 1
UNIT 4
UNIT 2
UNIT 3
EXIST. FAUX
BALCONY
OPEN TO
BELOW
OPEN TO
BELOW
OPEN TO
BELOW
OPEN TO
BELOW
7 1/4" 5'-1 3/4" 3'-0" 9'-9 3/4" 4'-0" 5'-7" 4'-0" 9'-0 3/4" 3'-0" 5'-2 1/4" 7 1/4"
50'-0" 14'-8 1/4" 3'-10 1/2" 6'-10" 3'-10 1/2" 14'-1 1/2" 7 1/4"44'-0"7 1/4" 5'-2 3/4" 3'-0" 9'-8 1/4" 4'-0" 5'-9 1/2" 4'-0" 9'-1 1/4" 3'-0" 4'-11 3/4" 7 1/4"
50'-0"19" 19"22'-3 9/16"
22'-3 9/16"
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
1/4" = 1'-0"
2ND FLOOR PLAN
- EXISTING
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA2.05014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 1/4" = 1'-0"1 2ND FLOOR PLAN - EXISTING
No. Revisions Date
05/14/18
11
10
5 5
11
10
1617 17 16
4 47 1/4"14'-1 1/2" 3'-10 1/2" 6'-10" 3'-10 1/2" 14'-1"7 1/4" 44'-0"DEMO ENTIRE FAUX
BALCONY/RAILING
UNIT 1
UNIT 4
UNIT 2
UNIT 3
OPEN TO
BELOW
OPEN TO
BELOW
OPEN TO
BELOW
OPEN TO
BELOW
7 1/4" 5'-1 3/4" 3'-0" 9'-9 3/4" 4'-0" 5'-7" 4'-0" 9'-0 3/4" 3'-0" 5'-2 1/4" 7 1/4"
50'-0"14'-8 1/4" 3'-10 1/2" 6'-10" 3'-10 1/2" 14'-1 1/2" 7 1/4"44'-0"7 1/4" 5'-2 3/4" 3'-0" 9'-8 1/4" 4'-0" 5'-9 1/2" 4'-0" 9'-1 1/4" 3'-0" 4'-11 3/4" 7 1/4"
50'-0"19" 19"22'-3 9/16"
22'-3 9/16"
DEMO ENTIRE FAUX
BALCONY/RAILING
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
1/4" = 1'-0"
2ND FLOOR PLAN
- DEMO
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA2.0D5014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 1/4" = 1'-0"1 2ND FLOOR PLAN - DEMO
No. Revisions Date
05/14/18
GRADE - EXISTING
0' - 0"
T.O. PLATE - EXISTING
10' - 6"
T.O. MAIN DECK - EXISTING
2' - 6"
1ST FLOOR PLAN - EXISTING
2' - 3"
2ND FLOOR PLAN - EXISTING
11' - 6"
T.O. ROOF - EXISTING
20' - 8"2'-3" 3" 8'-0" 1'-0" 9'-2"20'-8"2'-6"4
5 5
1 1
2
1
2
3
4
GRADE - EXISTING
0' - 0"
T.O. PLATE - EXISTING
10' - 6"
T.O. MAIN DECK - EXISTING
2' - 6"
1ST FLOOR PLAN - EXISTING
2' - 3"
2ND FLOOR PLAN - EXISTING
11' - 6"
T.O. ROOF - EXISTING
20' - 8"9'-2"1'-0" 8'-0" 3" 2'-3" 20'-8"2'-6"16
12 2
17
13 14
17
2 15
16
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
3/8" = 1'-0"
NORTH/SOUTH
ELEVATIONS -
EXISTING
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA3.05014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 3/8" = 1'-0"1 NORTH ELEVATION - EXISTING
3/8" = 1'-0"2 SOUTH ELEVATION - EXISTING
No. Revisions Date
05/14/18
GRADE - EXISTING
0' - 0"
T.O. PLATE - EXISTING
10' - 6"
T.O. MAIN DECK - EXISTING
2' - 6"
1ST FLOOR PLAN - EXISTING
2' - 3"
2ND FLOOR PLAN - EXISTING
11' - 6"
T.O. ROOF - EXISTING
20' - 8"2'-3" 3" 8'-0" 1'-0" 9'-2"20'-8"2'-6"4
5 5
1 1
2
1
2
3
4
DEMO ENTIRE
DECK/RAILING/STAIRS/
BENCHES/SHED
DEMO ALL
EXISTING
SIDING/TRIM
DEMO ENTIRE FAUX
BALCONY/RAILING
EXISTING CHIMNEYS
(TO REMAIN)
EXISTING CHIMNEYS
(TO REMAIN)
DEMO & REPLACE
EXISTING FASCIAS
& SOFFITS
GRADE - EXISTING
0' - 0"
T.O. PLATE - EXISTING
10' - 6"
T.O. MAIN DECK - EXISTING
2' - 6"
1ST FLOOR PLAN - EXISTING
2' - 3"
2ND FLOOR PLAN - EXISTING
11' - 6"
T.O. ROOF - EXISTING
20' - 8"9'-2"1'-0" 8'-0" 3" 2'-3" 20'-8"2'-6"16
12 2
17
13 14
17
2 15
16
DEMO ALL
EXISTING
SIDING/TRIM
DEMO ENTIRE
DECK/RAILING/STAIRS/
BENCHES
DEMO ENTIRE FAUX
BALCONY/RAILING
EXISTING CHIMNEYS
(TO REMAIN)
EXISTING CHIMNEYS
(TO REMAIN)
DEMO & REPLACE
EXISTING FASCIAS
& SOFFITS
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
3/8" = 1'-0"
NORTH/SOUTH
ELEVATIONS -
DEMO
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA3.0D5014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 3/8" = 1'-0"1 NORTH ELEVATION - DEMO
3/8" = 1'-0"2 SOUTH ELEVATION - DEMO
No. Revisions Date
05/14/18
NEW STONE BUMP-OUT
(AT CORNERS, +/- 10" THICK)
NEW UNIFORM TRIM
(FOR ALL WINDOWS & DOORS)
NEW STONE WALL
(TO HIDE STRUCTURE
UNDER NW DECK ONLY)
NEW EXTERIOR LIGHTING
("DARK LIGHTS" ONE PER UNIT)
NEW VERTICAL SIDING
(VERTICAL CHARRED CEDAR
SIDING, *PROFILE TBD)
NEW HORIZONTAL CEDAR SIDING
(w/ DARK, NATURAL STAIN)
NEW "BELLY BAND"
(10" TALL, DARK OR CHARRED TO
MATCH CHARRED SIDING)
NEW HORIZONTAL CEDAR SIDING
ON DORMERS
(w/ DARK, NATURAL STAIN)
NEW STONE BUMP-OUT
(AT CORNERS, +/- 10" THICK)
NEW UNIFORM TRIM
(FOR ALL WINDOWS & DOORS)
NEW EXTERIOR LIGHTING
("DARK LIGHTS" ONE PER UNIT)
NEW VERTICAL SIDING
(VERTICAL CHARRED CEDAR SIDING,
*PROFILE TBD)
NEW HORIZONTAL CEDAR SIDING
(w/ DARK, NATURAL STAIN)
NEW "BELLY BAND"
(10" TALL, DARK OR CHARRED TO
MATCH CHARRED SIDING)
NEW HORIZONTAL CEDAR SIDING
ON DORMERS
(w/ DARK, NATURAL STAIN)
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
3/8" = 1'-0"
NORTH/SOUTH
ELEVATIONS -
PROPOSED
05/23/2017G O RE C REEK C O N D O M IN IU M S| EX TERIO R REM O D ELA3.0P5014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 3/8" = 1'-0"1 NORTH ELEVATION - PROPOSED
3/8" = 1'-0"2 SOUTH ELEVATION - PROPOSED
No. Revisions Date
05/14/18
GRADE - EXISTING
0' - 0"
T.O. PLATE - EXISTING
10' - 6"
T.O. MAIN DECK - EXISTING
2' - 6"
1ST FLOOR PLAN - EXISTING
2' - 3"
2ND FLOOR PLAN - EXISTING
11' - 6"
T.O. ROOF - EXISTING
20' - 8"20'-8"9'-2"1'-0" 8'-0" 3" 2'-3" 2'-6"6 7 8 9
10 11
GRADE - EXISTING
0' - 0"
T.O. PLATE - EXISTING
10' - 6"
T.O. MAIN DECK - EXISTING
2' - 6"
1ST FLOOR PLAN - EXISTING
2' - 3"
2ND FLOOR PLAN - EXISTING
11' - 6"
T.O. ROOF - EXISTING
20' - 8"20'-8"2'-6"9'-2"1'-0" 8'-0" 3" 2'-3" 9 8 7 6
1011
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
3/8" = 1'-0"
EAST/WEST
ELEVATIONS -
EXISTING
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA3.15014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 3/8" = 1'-0"1 EAST ELEVATION - EXISTING
3/8" = 1'-0"2 WEST ELEVATION - EXISTING
No. Revisions Date
05/14/18
GRADE - EXISTING
0' - 0"
T.O. PLATE - EXISTING
10' - 6"
T.O. MAIN DECK - EXISTING
2' - 6"
1ST FLOOR PLAN - EXISTING
2' - 3"
2ND FLOOR PLAN - EXISTING
11' - 6"
T.O. ROOF - EXISTING
20' - 8"20'-8"9'-2"1'-0" 8'-0" 3" 2'-3" 2'-6"6 7 8 9
10 11
DEMO ENTIRE
DECK/RAILING/STAIRS/
BENCHES/SHED
DEMO ALL
EXISTING
SIDING/TRIM
DEMO ENTIRE
DECK/RAILING/STAIRS/
BENCHES
EXISTING CHIMNEYS
(TO REMAIN)
EXISTING CHIMNEYS
(TO REMAIN)
DEMO & REPLACE
EXISTING FASCIAS
& SOFFITS
GRADE - EXISTING
0' - 0"
T.O. PLATE - EXISTING
10' - 6"
T.O. MAIN DECK - EXISTING
2' - 6"
1ST FLOOR PLAN - EXISTING
2' - 3"
2ND FLOOR PLAN - EXISTING
11' - 6"
T.O. ROOF - EXISTING
20' - 8"20'-8"2'-6"9'-2"1'-0" 8'-0" 3" 2'-3" 9 8 7 6
1011
DEMO ENTIRE
DECK/RAILING/STAIRS/
BENCHES/SHED
DEMO ENTIRE
DECK/RAILING/STAIRS/
BENCHES
DEMO ALL
EXISTING
SIDING/TRIM
EXISTING CHIMNEYS
(TO REMAIN)
EXISTING CHIMNEYS
(TO REMAIN)
DEMO & REPLACE
EXISTING FASCIAS
& SOFFITS
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
3/8" = 1'-0"
EAST/WEST
ELEVATIONS -
DEMO
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA3.1D5014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 3/8" = 1'-0"1 EAST ELEVATION - DEMO
3/8" = 1'-0"2 WEST ELEVATION - DEMO
No. Revisions Date
05/14/18
NEW STONE BUMP-OUT
(AT CORNERS, +/- 10" THICK)
NEW UNIFORM TRIM
(FOR ALL WINDOWS & DOORS)
NEW VERTICAL SIDING
(VERTICAL CHARRED CEDAR
SIDING, *PROFILE TBD)
NEW HORIZONTAL CEDAR
SIDING ON DORMERS
(w/ DARK, NATURAL STAIN)
NEW UTILITY SHED FOR ELECT. METERS
(VERTICAL CHARRED CEDAR SIDING TO
MATCH MAIN WALLS, *PROFILE TBD)
NEW STONE BUMP-OUT
(AT CORNERS, +/- 10" THICK)
NEW UNIFORM TRIM
(FOR ALL WINDOWS & DOORS)LOWEST GRADE POINT TO T.O. STONE: 6'-0"T 1
*REVISION:
TOP OF STONE WALLS NOW ONLY
6FT FROM LOWEST GRADE POINT
PER CODE, USE WOOD PANELING
ABOVE STONE TO CONCEAL
STRUCTURE UNDER DECK.WOOD TRIM1'-11"T (*VERIFY)
NEW VERTICAL SIDING
(VERTICAL CHARRED CEDAR SIDING,
*PROFILE TBD)
NEW HORIZONTAL CEDAR
SIDING ON DORMERS
(w/ DARK, NATURAL STAIN)
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
3/8" = 1'-0"
EAST/WEST
ELEVATIONS -
PROPOSED
05/23/2017G O RE C REEK C O N D O M IN IU M S| EX TERIO R REM O D ELA3.1P5014 MAIN GORE DRIVE | VAIL, COLORADO, 81657
OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKI 3/8" = 1'-0"
1 EAST ELEVATION - PROPOSED
3/8" = 1'-0"
2 WEST ELEVATION - PROPOSED
No. Revisions Date
1 T.O. STONE 6 FT MAX.
FROM LOWEST GRADE
POINT @ NW STONE WALL
03/20/2017
Doors to meters 30" above grade
7" view holes at each meter
05/14/18
Scale:
Date:
*FIELD VERIFY
ALL DIM'S
MATERIAL
TAKEOFFS
05/23/2017G O RE C REEK C O N D O M IN IUM S| EXTERIO R REM O D ELA4.0P5014 MAIN GORE DRIVE | VAIL, COLORADO, 81657OWNERS: MELISSA HEWITT, STACY OHLSSON, JAMES & ELIZABETH KREZOWSKISIDING - VERTICAL CHARRED CEDAR (PROFILE TBD)
MATERIAL NAME WALL TYPE AREA (SF)
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (MAIN WALLS) 218.303 SF
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (MAIN WALLS) 217.683 SF
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (MAIN WALLS) 321.961 SF
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (MAIN WALLS) 319.468 SF
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (SHEDS) 81.156 SF
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (SHEDS) 46.469 SF
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (SHEDS) 42.141 SF
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (SHEDS) 83.708 SF
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (SHEDS) 46.469 SF
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (SHEDS) 42.141 SF
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (SHEDS) 24.306 SF
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (SHEDS) 9.5 SF
VERTICAL SIDING (CHARRED CEDAR) VERT. CHARRED SIDING (SHEDS) 7.012 SF
TOTAL: 1460.317 SF
SIDING - HORIZONTAL STAINED CEDAR
MATERIAL NAME WALL TYPE AREA (SF)
WALL SIDING
(NATURAL-STAINED CEDAR)
HORIZ. SIDING WALL
(NATURAL-STAINED CEDAR SIDING)
- DORMERS
129.351 SF
WALL SIDING
(NATURAL-STAINED CEDAR)
HORIZ. SIDING WALL
(NATURAL-STAINED CEDAR SIDING)
- DORMERS
26.881 SF
WALL SIDING
(NATURAL-STAINED CEDAR)
HORIZ. SIDING WALL
(NATURAL-STAINED CEDAR SIDING)
- DORMERS
26.812 SF
WALL SIDING
(NATURAL-STAINED CEDAR)
HORIZ. SIDING WALL
(NATURAL-STAINED CEDAR SIDING)
- DORMERS
130.108 SF
WALL SIDING
(NATURAL-STAINED CEDAR)
HORIZ. SIDING WALL
(NATURAL-STAINED CEDAR SIDING)
- DORMERS
26.881 SF
WALL SIDING
(NATURAL-STAINED CEDAR)
HORIZ. SIDING WALL
(NATURAL-STAINED CEDAR SIDING)
- DORMERS
26.812 SF
WALL SIDING
(NATURAL-STAINED CEDAR)
HORIZ. SIDING WALL
(NATURAL-STAINED CEDAR SIDING)
- MAIN WALLS
204.045 SF
WALL SIDING
(NATURAL-STAINED CEDAR)
HORIZ. SIDING WALL
(NATURAL-STAINED CEDAR SIDING)
- MAIN WALLS
202.813 SF
TOTAL: 773.702 SF
STONE WALLS - @ BLDG. CORNERS
MATERIAL NAME WALL TYPE AREA (SF)
STONE WALLS (@ BLDG. CORNERS) STONE WALLS @ CORNERS -
10" THICK
92.31 SF
STONE WALLS (@ BLDG. CORNERS) STONE WALLS @ CORNERS -
10" THICK
88.771 SF
STONE WALLS (@ BLDG. CORNERS) STONE WALLS @ CORNERS -
10" THICK
80.547 SF
STONE WALLS (@ BLDG. CORNERS) STONE WALLS @ CORNERS -
10" THICK
48.665 SF
STONE WALLS (@ BLDG. CORNERS) STONE WALLS @ CORNERS -
10" THICK
38.527 SF
STONE WALLS (@ BLDG. CORNERS) STONE WALLS @ CORNERS -
10" THICK
38.527 SF
STONE WALLS (@ BLDG. CORNERS) STONE WALLS @ CORNERS -
10" THICK
48.665 SF
STONE WALLS (@ BLDG. CORNERS) STONE WALLS @ CORNERS -
10" THICK
80.547 SF
TOTAL: 516.558 SF
STONE WALLS - UNDER NW DINING DECK
MATERIAL NAME WALL TYPE AREA (SF)
CMU WALLS + STONE VENEER
(NW DECK)
8" CMU WALLS (NW DECK) -
WITH STONE VENEER
61.667 SF
CMU WALLS + STONE VENEER
(NW DECK)
8" CMU WALLS (NW DECK) -
WITH STONE VENEER
39.969 SF
CMU WALLS + STONE VENEER
(NW DECK)
8" CMU WALLS (NW DECK) -
WITH STONE VENEER
61.667 SF
CMU WALLS + STONE VENEER
(NW DECK)
8" CMU WALLS (NW DECK) -
WITH STONE VENEER
39.969 SF
CMU WALLS - WITHOUT STONE
VENEER (NW DECK)
8" CMU WALLS (NW DECK) -
WITHOUT STONE VENEER
30.685 SF
TOTAL: 233.957 SFDECKS - TREX or WOOD DECKING (TBD)
MATERIAL NAME DECK TYPE AREA (SF)
DECKING (TREX or WOOD) DECKS (TREX or WOOD - DINING DECKS) 241.925 SF
DECKING (TREX or WOOD) DECKS (TREX or WOOD - DINING DECKS) 187.62 SF
DECKING (TREX or WOOD) DECKS (TREX or WOOD - MAIN DECKS) 867.019 SF
DECKING (TREX or WOOD) DECKS (TREX or WOOD - MAIN DECKS) 595.628 SF
DECKING (TREX or WOOD) DECKS (TREX or WOOD - MAIN DECKS) 8 SF
TOTAL: 1900.192 SF
STAIRS - TREX or WOOD DECKING (TBD)
MATERIAL NAME STAIR TYPE AREA (SF)
STAIRS (TREX or WOOD) STAIRS 5.75" 23.496 SF
STAIRS (TREX or WOOD) STAIRS 6.5" 9.562 SF
STAIRS (TREX or WOOD) STAIRS 6.5" 9 SF
STAIRS (TREX or WOOD) STAIRS 6.5" 3 SF
STAIRS (TREX or WOOD) STAIRS 6.5" 3 SF
STAIRS (TREX or WOOD) STAIRS 6.5" 3 SF
TOTAL: 51.057 SF
BENCHES - TREX or WOOD DECKING (TBD)
MATERIAL NAME LOCATION/TYPE AREAS (SF)
BENCHES (TREX or WOOD) N&S DECKS BUILT-IN BENCHES (15"D x 18"T) -
SOUTH DECK 43.15 SF
BENCHES (TREX or WOOD) N&S DECKS FLOATING BENCHES (18"D x 18"T
x 3.5" THICK) - NORTH DECK 21.25 SF
TOTAL: 64.4 SF
PLANTERS - TREX or WOOD DECKING (TBD)
MATERIAL NAME TYPE/LOCATION AREA OF SIDES (SF)
PLANTERS (TREX or WOOD) BUILT-IN PLANTERS - SOUTH DECK (15"D x 36"T) 246.975 SF
PLANTERS (TREX or WOOD) HANGING PLANTERS - NORTH DECK (18"D x 13"T) 85.042 SF
TOTAL: 332.017 SF
RAILING SCHEDULE
RAILING TYPE LENGTH (LF)
FORTRESS-VERTICAL CABLE RAIL (DECKS) 165' - 2 5/8"
FORTRESS-VERTICAL CABLE RAIL (STAIRS) 21' - 9 19/32"
HORIZONTAL SLAT RAILING 31' - 3"
TOTAL 218' - 3 7/32"
REPLACEMENT FASCIA
LENGTH (LF)
299' - 0 31/32"
REPLACEMENT SOFFITS
LENGTH (LF)
299' - 10 19/32"
BELLY BOARDS (10" TALL)
LENGTH
63' - 8"
STONE ACCENTS (GRILL AREA & FIRE PIT)
MATERIAL NAME AREA (SF)
GAS FIRE PIT: MATERIALS
SOLID STONE TOP/LEDGE (FIRE PIT) 34.833 SF
STACKED STONE WALLS (FIRE PIT) 88.5 SF
GAS GRILL AREA: MATERIALS
SOLID STONE COUNTERS (GRILL) 22.567 SF
STACKED STONE WALLS (GRILL AREA) 94.672 SF
HOT TUB & FIRE PIT DIMENSIONS
HOT TUB: 100"W x 91"L x 38"T
GAS FIRE PIT: 66"W x 66"L (Incl. 1" Ledge Ovhg.) x 24"T (Incl. 2" Stone Top)
No. Revisions Date
FIXTURES/WIRING/ETC. FOR:
NEW "DARK LIGHT" EXTERIOR WALL FIXTURES
*VERIFY IF OTHER EXISTING LIGHTING NEEDS REPLACEMENT
4 COUNT
05/14/18
05/14/18
05/14/18
05/14/18
05/14/18
05/14/18