HomeMy WebLinkAboutA18-0024_approved documents_1526654638.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Fire - Construction Permit A18-0024 Issued: 05/18/2018 TOWN OF VAIL Property Information Address: 551 N FRONTAGE RD W (210106302013) ( 210106302013 ) Unit #: Parcel Number: 210106302013 Legal Description: RED SANDSTONE ELEMENTARY SCHOOL Contacts Contact Type: Applicant Full Name: Tim Ward Address: 210 Marmot Lane B5 Eagle, CO 81631 Phone: 970.328.1951 Contact Type: Property Owner Full Name: EAGLE COUNTY SCHOOL DISTRICT RE-50J Address: Phone: None Contractor Contractor Type: Alarm Company: Commercial Specialists Of Western Colorado, LLC State License #: Phone: 970-328-1951 Project Information Project Name: Red Sandstone Elementary 2017 Project Description: RSPG - Installation of new fire alarm system throughout new parking garage. Fees Paid Conditions Issued By: Town of Vail Fire and Emergency Services Department NOTICE: By issuance of this Permit the applicant agrees to comply to all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. RED SANDSTONE PARKING GARAGE 551 NORTH FRONTAGE ROAD WEST VAIL, COLORADO FIRE ALARM PRODUCT DATA SUBMITTAL Fire Alarm Contractor: Commercial Specialists, Inc 601 Mulberry Street Grand Junction, CO 81501 Ph: (970) 241-0268 DATE: 5/1/18 DN-60959:A • 3/6/2018 — Page 1 of 4 NFW-100X Intelligent Addressable FACP with Communicator General The FireWarden-100X (NFW-100X) is the latest intelligent address- able Fire Alarm Control Panel (FACP) within the FireWarden Series. The NFW-100X comes with a pre-installed communicator and sup- ports up to 198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the NFW-100X programs just like FireWarden-100 products, yet fits into applications previ- ously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator’s internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-N. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel’s USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTM). Features •Listed to UL Standard 864, 10th edition •Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator over AlarmNet •Optional CELL-MOD or CELL-CAB-N GSM Central Station Com- municator over AlarmNet® •Automated activation of the NFC-50/100 Emergency Command Center •NFC-FFT Firefighter Telephone option •Compatible with SWIFT® wireless devices •Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address •Four built-in, independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits •Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices •Notification Appliance Circuit End of Line resistor matching •Four programmable function keys for ease of maintenance •Two programmable relays and one fixed trouble relay •Built-in Programmer •Integral 80-character LCD display with backlighting •Real-time clock/calendar with automatic daylight savings control •History file with 1,000 event capacity •Addressable sounder base compatibility •Control module delay timer •Automatic detector sensitivity testing (NFPA 72 compliant) •Automatic device type-code verification •Point trouble identification •Waterflow selection per module point •Alarm verification selection per detector point •Maintenance alert warns when smoke detector dust accumula- tion is excessive •One-person audible or silent walk test with walk-test log and printout •System alarm verification selection per detector point •PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) •Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus •Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator •Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP •Supports FlashScan® and CLIP protocols •SLC operates up to 10,000 ft. (3,000 m) in FlashScan mode with twisted, unshielded wire •Single addressable SLC loop which meets NFPA Class B and Class A requirements •198 addressable device capacity (99 addressable detectors and 99 modules) •Compatible with NOTIFIER FireWarden and ONYX Series addressable devices (refer to the FireWarden SLC Wiring Man- ual) NOTIFICATION APPLIANCE CIRCUITS (NACS) • Four independently programmable output circuits. Circuits can be configured for the following outputs: –Style Y (Class B) –Style Z (Class A) • Silence Inhibit and Autosilence timer options • Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability • Selectable strobe synchronization per NAC • 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7A Page 2 of 4 — DN-60959:A • 3/6/2018 PROGRAMMING AND SOFTWARE •Autoprogramming (learn mode) reduces installation time •Custom English labels (per point) may be manually entered or selected from an internal library file •Two programmable Form-C relay outputs •99 software zones •Continuous fire protection during online programming •Program Check automatically catches common errors not linked to any zone or input point • OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows®-based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.notifier.com. User interface LED INDICATORS KEYPAD PRODUCT LINE INFORMATION NFW-100X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display chassis with trans- former, backbox with door, plastic bag containing screws, cables, key, etc. FS-Tools: Programming software for Windows®-based PC com- puter. Available for download at www.notifier.com. CELL-CAB-N/CELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the NFW-100X (red). DP-ES-B: Optional dress panel for NFW-100X (black). TR-CE-B: Optional trim ring for semi-flush mounting. (Black. For red, order TR-CE.) BB-XP: Optional cabinet for one or two modules. BB-25: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG- 75. NFS-LBB: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-25 cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than 18AH. BAT Series: Batteries, see data sheet DN-6933. PRN Series: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTM Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. PWRMOD24 Power Expander Module: Optional power module. Increases alarm power output to 6 amps. COMPATIBLE ANNUNCIATORS N-ANN-80: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. (Basic model is black; order -W for white; see DN-7114.) N-ANN-100R: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. (Basic model is black; order R for red.) N-ANN-I/O: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DN-7105.) N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DN-60242.) N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242.) N-ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DN-7107.) N-ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) ADDRESSABLE DEVICES FSP-951: Addressable low-profile photoelectric smoke detector. FlashScan only. FSP-951-IV: Addressable low-profile photoelectric smoke detector. Ivory. FlashScan and CLIP mode. NP-200: Addressable low-profile photoelectric smoke detector. B300-6 base included, FlashScan only. NP-200-IV: Addressable low-profile photoelectric smoke detector. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951T: Addressable low-profile photoelectric smoke detector with thermal sensor. FlashScan only. FSP-951T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. FlashScan and CLIP mode. NP-200T: Addressable low-profile photoelectric smoke detector with thermal sensor. B300-6 base included. FlashScan only. NP-200T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. FSP-951R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. FlashScan and CLIP mode. NP-200R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. NP-200R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory, FlashS- can and CLIP mode. FST-951: Low-profile 135°F fixed thermal sensor. FlashScan only. FST-951-IV: Low-profile 135°F fixed thermal sensor. Ivory. FlashS- can and CLIP mode. NH-200: Low-profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200-IV: Low-profile 135°F fixed thermal sensor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. FST-951R: Low-profile, intelligent, rate-of-rise thermal sensor. FlashScan only. FST-951R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. FlashScan and CLIP mode. •Fire Alarm (red) •CO Alarm (red) •AC Power (green) •Supervisory (yellow) •Trouble (yellow) •Ground fault (yellow) •Battery fault (yellow) •Disabled (yellow) •Maintenance (yellow) •Communication (yellow) •Alarm Silenced (yellow)•F1-F4 Programmable Function Keys (yellow) •16 key alpha-numeric pad •Acknowledge •Alarm Silence •Drill (Manual Evacuate) •Four (4) programmable function keys•Reset (lamp test) DN-60959:A • 3/6/2018 — Page 3 of 4 NH-200R: Low-profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200R-IV: Low-profile 135°F fixed thermal sensor. Ivory. B300-6- IV base included, FlashScan and CLIP mode. FST-951H: Low-profile intelligent 190°F/88°C fixed thermal sensor. FlashScan only. FST-951H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- sor. Ivory. FlashScan and CLIP mode. NH-200H: Low-profile intelligent 190°F/88°C fixed thermal sensor. B300-6 base included, FlashScan only. NH-200H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- sor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. Legacy Devices FSI-851: Addressable low-profile ionization smoke detector. NI-100: Addressable low-profile ionization smoke detector. FSP-851: Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. FSP-851T: Addressable low-profile photoelectric smoke detector with thermal sensor. NP-100T: Addressable low-profile photoelectric smoke detector with thermal sensor. FSP-851R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. NP-100R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FST-851: Fast-response, low-profile heat detector. NH-100: Fast-response, low-profile heat detector. FST-851R: Fast-response, low-profile heat detector with rate-of-rise option. NH-100R: Fast-response, low-profile heat detector with rate-of-rise option. FST-851H: Fast-response, low-profile heat detector that activates at 190°F/88°C. NH-100H: Fast-response, low-profile heat detector that activates at 190°F/88°C. FAPT-851: Addressable low-profile multi-sensor detector. NP-A100: Addressable low-profile multi-sensor detector. B200SR: Addressable sounder base. DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order FSP-851R, FSP-951R, or NP-100R separately.) DNRW: InnovairFlex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order FSP-851R, FSP-951R, or NP- 100R separately.) Addressable Modules FMM-1: Addressable Monitor Module for one zone of normally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NMM-100: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. FDM-1: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs. NDM-100: Dual Monitor Module. Same as NMM-100 except it pro- vides two Style B (Class B) only IDCs. FMM-101: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. FZM-1: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. NZM-100: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. FCM-1: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. FRM-1: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NBG-12LX: Addressable manual pull station with interface module mounted inside. NOT-BG12LX: Addressable manual pull station with interface mod- ule mounted inside. ISO-X: Fault Isolator Module. N100-ISO: Fault Isolator Module. ISO-6: Six-fault isolator module. Mount one or two modules in a BB- XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SMB500: Used to mount all modules except the FMM-101/NMM- 100P. NMM-100-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NZM-100-6: Six-zone interface module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SWIFT Wireless Devices FWSG: Wireless Gateway FWD-200P: intelligent, wireless photo detector. FWH-200ROR135: LiteSpeed intelligent wireless rate of rise (135°) heat detector. FWD-200ACCLIMATE: Wireless Acclimate Detector FWH-200FIX135: intelligent wireless fixed-temperature (135°) heat detector. FW-MM: Intelligent wireless monitor module. FW-RM: Intelligent wireless relay module. NBG-12LW: Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the FireWarden-100X, see the following data sheets (document numbers): NP-200 Series (DN-60979), NH-200 Series (DN-60980), FSP-851 Series (DN-6935), FSP-951 Series (DN-60977), FST-851 Series (DN-6936), FST-951 Series (DN-60975), FAPT-851 (DN-6937), N100-ISO (DN-6994), NP-100 series (DN-6995), NH-100/NH-100R (DN- 6997), DNR/InnovairFlex (DN-60424, DN-60429), NP-A100 (DN-6998), NMM-100/NMM-100P/NDM-100/NZM-100 (DN-6999), NC-100 (DN- 7000), NC-100R (DN-60383), NMM-100-10 (DN-6990), MM-1/FDM-1/ FZM-1/FMM-101 (DN-6720), FCM-1/FRM-1 (DN-6724), NOT-BG12LX (DN-7001), NBG-12LX (DN-6726), and FireWarden SLC Manual (52304). AlarmNet®, NOTIFIER®, FireWarden®, SWIFT®, and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of Origin: USA NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com SPECIFICATIONS System Capacity •Intelligent Signaling Line Circuits................................................1 •Addressable device capacity..................................................198 •Programmable software zones.................................................99 • Annunciators.............................................................................16 Electrical Specifications AC Power: 120/240 VAC, 50/60 Hz, 3.25A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, super- vised. Battery: Two 12 V 18AH lead-acid batteries. Battery Charger Capacity: 7-18AH (FireWarden-100X cabinet holds maximum of two 18AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connec- tions for four NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5amps special application, 250mA regulated. End-of-Line Resistor: 4.7kohm, ½ watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 kΩ - 22kΩ ELR range. Refer to the NOTIFIER Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0A @ 30 VDC (resistive), 0.5A @ 30 VAC (resistive). Form-C relays, non-power-limited, non-supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE/B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00” (50.80 cm.) high x 22.5” (57.15 cm.) wide x 8.5” (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 – 49°C/32 –120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. Addressable Device Accessories End-of-Line Resistor Assembly (R-47K and R-3.9K): The 47kohm assembly supervises the NMM-100-10, NDM-100, NMM- 100P, and NC-100 module circuits. The 3.9kohm assembly super- vises the NZM-100-6 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. NFPA Standards The FireWarden-100X complies with the following NFPA 72 Fire Alarm Systems requirements: – LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). – AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). –REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) – PROPRIETARY (Automatic, Manual and Waterflow). –CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). –OT, PSDN (Other Technologies, Packet-switched Data Net- work) –IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). –CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic FireWarden- 100X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S635 • CSFM: 7165-0028:0505 DN-6937:D • 12/07/2011 — Page 1 of 2 FAPT-851(A) Acclimate® Plus™ Multi-Sensor Low-Profile Intelligent Detector Intelligent/Addressable Devices DN-6937:D General The Notifier FAPT-851(A) Acclimate® Plus™ detector is an intelligent, addressable, multi-sensing, low-profile detector designed for use with Notifier Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). The Acclimate Plus detector uses a combination of photoelec- tric and thermal sensing technologies to increase immunity to false alarms. Unlike traditional intelligent detectors, the Accli- mate Plus detector has a microprocessor in the detector head that processes alarm data. As a result, the Acclimate Plus detector adjusts its sensitivity automatically, without operator intervention or control panel programming. Areas where the Acclimate Plus detector is especially useful include office complexes, schools, college campuses, manu- facturing and industrial facilities, and anywhere else the use of a particular area may change. The Acclimate Plus detector automatically adjusts its sensitivity to the environment. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed to greatly enhance the speed of communica- tion between analog intelligent devices and compatible systems. Intelligent devices communicate in a grouped fash- ion. If one of the devices within the group has new information, the panel’s CPU stops the group poll and concentrates on sin- gle points. The net effect is response speed greater than five times that of earlier designs. Features •Automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. •Microprocessor-based, combination photo and thermal technology. •Compatible with all Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). •Addressable-analog communication. •Sleek, low-profile design. •Two-wire SLC connection. •Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). •Addresses can be viewed and changed without electronic programmers. •Dual bi-color LED design provides 360° viewing angle. •LEDs lock red when in alarm. In FlashScan, LEDs flash green in standby for normal condition. •Built-in tamper-resistant feature. •Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. •SEMS screws for wiring of the separate base. •Several base options, including relay, isolator, and sounder. •Built-in functional test switch activated by external magnet. •Listed to UL 268. •Capable of heat-only alarm mode, enabled by a special command from the panel. Smoke alarms are ignored. •Low-temperature signal at 45°F +/– 10°F (7.22°C +/– 5.54°C). Specifications Sensitivity: auto-adjusting levels: 1 to 2%/ft. and 2 to 4%/ft. with classic CLIP systems; 1 to 2, 2 to 3, and 3 to 4%/ft. with systems; fixed-sensitivity levels: 1, 2, and 4%/ft. with classic CLIP systems; 0.5, 1, 2, 3, and 4%/ft. with FlashScan systems. Size: 2.0" (5.3 cm) high; base determines diameter. – B210LP(A): 6.1" (15.5 cm) diameter. – B501(A): 4.1" (10.4 cm) diameter. – B200S(A): 6.875" (17.46 cm) diameter. – B200SR(A): 6.875" (17.46 cm) diameter. – B224RB(A): 6.2" (15.748 cm) diameter. Shipping weight: 5.2 oz. (147 g). Operating temperature: 0°C to 38°C (32°F to 100°F). UL-Listed velocity range: 0 – 4000 ft./min. (1219.2 m/min.), suitable for installation in ducts. Relative humidity: 10% – 93% noncondensing. Thermal sensing rating: fixed-temperature setpoint 135°F (57°C). ELECTRICAL SPECIFICATIONS Voltage range: 15 – 32 volts DC peak. Standby current (max. avg.): 300 A. Loop resistance: 50 ohms maximum; varies according to control panel used. Refer to panel installation manuals. LED current (max.): 6.5 mA @ 24 VDC (“ON”). Installation The FAPT-851(A) plug-in detector uses a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove detec- tors without using a ladder. Suitable mounting base boxes include: FAPT-851(A) in B210LP(A) Base FAPT-851 with B210.png Page 2 of 2 — DN-6937:D • 12/07/2011 Notifier®, ONYX®, FlashScan®, and Acclimate® are registered trademarks and Acclimate Plus™ is a trademark of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. •4.0" (10.16 cm) square box. •3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. •Single-gang box (except relay or isolator base). NOTE: The FAPT-851(A) detector has the unique ability to adjust sensitivity according to the environment, based on heat and smoke levels. Avoid installing these detectors in locations that are susceptible to rapid and high temperature changes. An example of an incorrect application would be near or in line with the output of a self-contained heater. Agency Listings and Approvals These listings and approvals apply to the modules specified in this. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL Listed: S1115. • ULC Listed: S1115. • MEA Listed: 225-02-E. •FM Approved. • CSFM: 7272-0028:0206. • U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B210LP(A)). • Lloyd’s Register: 11/600013 (NFS2-640, NFS-320/NFS- 320C, excluding B210LP(A)). • Maryland State Fire Marshal: Permit # 2122. Ordering Information NOTE: “A” suffix indicates ULC Listed model. FAPT-851: Low-profile intelligent multi-sensor detector. FAPT-851A: Same as FAPT-851 but with ULC Listing. INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B210LP(A): Plug-in detector base; standard U.S. flanged low- profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tem- poral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Relay base Screw terminals: up to 14 AWG (2.0 mm²). Relay type Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224BI(A): Isolator base. Maximum: 25 devices between iso- lator bases. ACCESSORIES F110: Retrofit flange to convert B210LP to match the B710LP profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Fits U.S. single-gang electrical box. Supported by B210LP(A) and B501(A) bases only. SMB600: Surface mounting kit for use with B210LP(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. T55-127-010: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. DN-6726:D • 4/13/2012 — Page 1 of 2 NBG-12LX Addressable Manual Pull Station Intelligent/Addressable Devices DN-6726:D • H-240 The NBG-12LX Addressable Manual Pull Station 6643cov1.jpg‘General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features •Maintenance personnel can open station for inspection and address setting without causing an alarm condition. •Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. •Handle latches in down position and the word “ACTIVATED” appears to clearly indicate the station has been operated. •Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm² wire). •Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. •Smooth dual-action design. •Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. •Highly visible. •Attractive shape and textured finish. •Key reset. •Includes Braille text on station handle. •Optional trim ring (BG12TR). •Meets UL 38, Standard for Manually Actuated Signaling Boxes. •Up to 99 NBG-12LX stations per loop on CLIP protocol loops. •Up to 159 NBG-12LX stations per loop on FlashScan® pro- tocol loops. •Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications • Shipping Weight: 9.6 oz. (272.15 g) • Normal operating voltage: 24 VDC. • Maximum SLC loop voltage: 28.0 VDC. • Maximum SLC standby current: 375 A. • Maximum SLC alarm current: 5 mA. • Temperature Range: 32°F to 120°F (0°C to 49°C) • Relative Humidity: 10% to 93% (noncondensing) • For use indoors in a dry location Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word “ACTI- VATED” (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 – 159 on FlashScan® systems, 1 – 99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or Page 2 of 2 — DN-6726:D • 4/13/2012 NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. 4"(10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA: 67-02-E. • CSFM: 7150-0028:0199. •FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). • BSMI: CI313066760047. •U.S. Coast Guard. •Lloyd’s Register. •FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. DN-6720:E • 07/30/2015 — Page 1 of 4 FMM-1(A), FMM-101(A), FZM-1(A) & FDM-1(A) Monitor Modules with FlashScan® Intelligent/Addressable Devices DN-6720:E General Four different monitor modules are available for Notifier’s intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1(A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that mon- itors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. FMM-1(A) Monitor Module •Built-in type identification automatically identifies this device as a monitor module to the control panel. •Powered directly by two-wire SLC loop. No additional power required. •High noise (EMF/RFI) immunity. •SEMS screws with clamping plates for ease of wiring. •Direct-dial entry of address: 01 – 159 on FlashScan loops; 01 – 99 on CLIP loops. •LED flashes green during normal operation (programma- ble option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 μA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FMM-1(A) (TypeH)6999cov.jpg Page 2 of 4 — DN-6720:E • 07/30/2015 FMM-101(A) Mini Monitor Module •Built-in type identification automatically identifies this device as a monitor module to the panel. •Powered directly by two-wire SLC loop. No additional power required. •High noise (EMF/RFI) immunity. •Tinned, stripped leads for ease of wiring. •Direct-dial entry of address: 01 – 159 on FlashScan loops; 01 – 99 on CLIP loops. The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 μA, 1 communication every 5 seconds, 47k EOL; 600 μA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 μA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM-1(A) Interface Module •Supports compatible two-wire smoke detectors. •Supervises IDC wiring and connection of external power source. •High noise (EMF/RFI) immunity. •SEMS screws with clamping plates for ease of wiring. •Direct-dial entry entry of address: 01 – 159 on FlashScan loops, 01 – 99 on CLIP loops. •LED flashes during normal operation; this is a program- mable option. •LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing systems. FZM-1(A) APPLICATIONS Use the FZM-1(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 μA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals T10 and T11): •DC voltage: 24 volts power limited. •Ripple voltage: 0.1 Vrms maximum. •Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C).6720m101.wmf DN-6720:E • 07/30/2015 — Page 3 of 4 Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1(A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 μA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 μA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1(A) is set to address “26”, then it will automatically assign itself to addresses “26” and “27”. NOTE: “Ones” addresses on the FDM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635. • ULC: S635. •FM Approved. • CSFM: 7300-0028:0219, 7165-0028:0224, 7165-0028:0243. • MEA: 457-99-E. • U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, NFS2-3030). • Lloyd’s Register: 11/600013 (NFS2-640, NFS2-320, NFS2-3030). • Fire Dept. of New York: COA #6121 (NFS2-640, NFS- 320), COA# 6114 (NFS2-3030). Product Line Information NOTE: “A” suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-101(A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. ! CAUTION: Avoid duplicating addresses on the system. Page 4 of 4 — DN-6720:E • 07/30/2015 FlashScan® and NOTIFIER® are registered trademarks and FireWatch™ is a trademark of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Agency Listings Features • Weatherproof NEMA 4X, IP56 rated • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from –40°F to 151°F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Listed for ceiling or wall mounting SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from −40°F to 151°F. Like the entire SpectrAlert Advance line, outdoor strobes and horn strobes for ceiling applications include a variety of features that increase application flexibility and simplify installation. First, field- selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Plastic and metal weatherproof back boxes come with ¾-inch top and bottom conduit entries and ¾-inch knock-outs at the back. Three screw-in NPT plugs with O-ring gaskets for a watertight seal is included with each back box. Outdoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. MEA452-05-E3023572 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn strobes, chime strobes) 7135-1653:189 (horns, chimes) S4011 (chimes, horn strobes, horns) S3593 (outdoor and alert strobes) AVDS11401 SpectrAlert Advance Outdoor Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Outdoor SpectrAlert Advance products shall operate between −40 and 151 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1638 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1638 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four- wire products, the strobe shall be powered independently of the sounder. The horn strobe on a 2-wire model shall work on a non-coded power supply. The horn on 4-wire horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor listed per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range with MDL3 Sync Module 8.5 to 17.5V (12 V nominal) or 16.5 to 33V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8˝ diameter × 2.5˝ high (173 mm diameter × 64 mm high) Strobe / Horn Strobe Dimensions 5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D) Strobe / Horn Strobe Dimensions with Back Box 5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D) Ceiling-Mount Weatherproof Back Box Dimensions 7.1˝ diameter × 2.0˝ high (180 mm diameter × 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS11401 Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7† Coded High 82 82 88 88 93 92 101 101 8† Coded Medium 78 78 85 85 90 90 97 98 9† Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobe. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 UL Max. Horn Current Draw for 4-Wire Horn Strobes (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Horn Tones and Sound Output DataCandela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2015 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS11402 • 02/15 SpectrAlert Advance Diagrams Model Description Ceiling Horn Strobes PC2RK 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) PC2RHK 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) PC2WK 2-Wire, Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) PC2WHK 2-Wire, Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Ceiling Strobes SCRK Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SCRHK Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SCWK Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SCWHK Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Accessories SA-WBBC Red, Metal Weatherproof Back Box SA-WBBCW White, Metal Weatherproof Back Box MP120K SpectrAlert Advance Ordering Information Notes: “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing outdoor units, both the device and back box must be replaced. 6.8®Dia. 2.5® Ceiling-Mount Horn Strobes Ceiling-Mount Horn Strobe with Plastic Weatherproof Back Box Ceiling Plastic Weatherproof Back Box DN-60938:A • 2/3/2017 — Page 1 of 4 Indoor Selectable-Output Strobes and Horn Strobes for Ceiling Applications Audio/Visual Devices DN-60938:A SCRL PC2WL General System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthet- ics. The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any appli- cation requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually elim- inating costly and time-consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela set- tings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Features •Plug-in design with minimal intrusion into the back box •Tamper-resistant construction •Automatic selection of 12- or 24-volt operation at 15 and 30 candela •Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 •Horn rated at 88+ dBA at 16 volts •Rotary switch for horn tone and two volume selections •Universal mounting plate for ceiling units •Mounting plate shorting spring feature checks wiring conti- nuity before device installation •Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices •Compatible with MDL3 sync module •Listed for ceiling mounting only Architect/Engineer Specifications GENERAL L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17/8 inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall termi- nate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24- volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regu- lated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. STROBE The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective ser- vice. The strobe shall be wired as a primary-signaling notifica- tion appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. HORN STROBE COMBINATION The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signal- ing appliances, flashing at 1 Hz over the strobe’s entire operat- ing voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pat- tern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non- coded power supply. Page 2 of 4 — DN-60938:A • 2/3/2017 SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 × 411/16 × 21/8 inch back box. The module shall also con- trol two Style Y (class B) circuits or one Style Z (class A) cir- cuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAL/ELECTRICAL SPECIFICATIONS • Standard Operating Temperature: 32°F to 120°F (0°C to 49°C) • Humidity Range: 10 to 93% non-condensing • Strobe Flash Rate: 1 flash per second • Nominal Voltage: Regulated 12VDC or regulated 24DC/ FWR1 • Operating Voltage Range2: 8 to 17.5V (12V nominal) or 16 to 33V (24V nominal) • Operating Voltage Range with MLD3: 8.5 to 17.5V (12V nominal) or 16.5 to 33V (24V nominal) • Input terminal wire gauge: 12 to 18 AWG • Ceiling-Mount Dimensions (including lens): 6.8" diame- ter 2.5" high (173 mm diameter 64 mm high) • Ceiling-Mount Surface Mount Back Box Skirt Dimen- sions (SBBCR, SBBCW): 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1.Full Wave Rectified (FWR) voltage is a non-filtered, time varying power source that is used on some power supply and panel outputs. 2.P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. UL Current Draw Data UL MAX. STROBE CURRENT DRAW (MA RMS) *This data represents coding at 3 chimes per second. Actual current draw will vary depending upon coding selected. Candela 8–17.5 Volts 16–33 Volts DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 DN-60938:A • 2/3/2017 — Page 3 of 4 UL MAX. CHIME/STROBE CURRENT DRAW (MA RMS), 2-WIRE HORN STROBE Horn Strobe Tones and Sound Output Data HORN AND HORN STROBE OUTPUT (DBA) Candela 8 VDC 16 VDC 15 30 15 30 75 95 115 150 177 EM Temp Hi 103 167 71 90 143 165 187 217 254 EM Temp Low 96 165 54 71 137 161 185 211 249 EM Cont Hi 106 173 71 90 141 165 187 230 273 EM Cont Low 95 166 54 71 124 161 170 216 258 3.1K Temp Hi 111 164 69 94 147 163 184 229 257 3.1K Temp Low 103 163 54 88 143 155 185 212 252 3.1K Cont Hi 111 172 69 94 144 164 202 229 271 3.1K Cont Low 103 169 54 88 131 155 187 217 259 Candela 16VFWR 15 30 75 95 115 150 177 EM Temp Hi 107 135 179 198 223 254 286 EM Temp Low 78 101 151 172 199 229 262 EM Cont Hi 107 135 179 198 223 254 286 EM Cont Low 78 101 151 172 199 229 262 3.1K Temp Hi 108 135 179 200 225 255 289 3.1K Temp Low 79 101 150 171 196 229 260 3.1K Cont Hi 108 135 179 200 225 255 289 3.1K Cont Low 79 101 150 171 196 229 260 Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 Page 4 of 4 — DN-60938:A • 2/3/2017 NOTIFIER® and SpectrAlert® are registered trademarks and Sync•Circuit™ is a trademark of Honeywell International Inc. ©2017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Product Drawings: L-Series Dimensions Agency Listings and Approvals The listings and approvals below apply to L-series devices. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC-Listed – S4011 Ceiling horn strobes – S5512 Ceiling strobes – S5512 ALERT strobes with clear lenses •FM Approved Product Line Information Note: ULC-listed devices include required French labeling. See Agency Listings for listing details. CEILING HORN STROBES PC2WL, PC2RL. 2-Wire, Horn Strobe (White, Red). CEILING STROBES SCWL, SCRL. Strobe (White, Red). SCWL-CLR-ALERT. Strobe, ALERT (White). ACCESSORIES TR-2W, TR-2. Universal Wall Trim Ring (White, Red). SBBCWL, SBBCRL. Ceiling Surface Mount Back Box (White, Red).oly_ceil_horn_strobe_datasheet_08152016_OL.epsHorn Strobes (Ceiling) Surface Mount Back Box (Ceiling) Agency Listings Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from –40°F to 151°F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Listed for ceiling or wall mounting SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from −40°F to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with ¾-inch top and bottom conduit entries and ¾-inch knock-outs at the back. A screw-in NPT plug with an O-ring gasket for a watertight seal is included with each back box. Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. MEA452-05-E3023572 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn strobes, chime strobes) 7135-1653:189 (horns, chimes) S4011 (chimes, horn strobes, horns) S3593 (outdoor and alert strobes) AVDS01201 SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between −40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6˝ L × 4.7˝ W × 2.5˝ D (142 mm L × 119 mm W × 64 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7˝ L × 5.1˝ W × 2.0˝ D (145 mm L × 130 mm W × 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7† Coded High 82 82 88 88 93 92 101 101 8† Coded Medium 78 78 85 85 90 90 97 98 9† Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobe. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Horn Tones and Sound Output DataCandela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS01201 • 3/12 SpectrAlert Advance Diagrams Model Description Wall Horn Strobes P2RK*† 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*† 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*† 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*† 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RK† 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*† Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*† Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*† Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*† Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRK† Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2RK-P. † Add “-R” to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 4.7® 5.6® 2.5® Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box Wall-Mount Horn Strobe with Plastic Weatherproof Back Box