Construction
B18-0090
Issued: 05/17/2018
TOWN OF VAIL
Property Information
Address: 2794 SNOWBERRY DR (210314301046) ( 210314301046 )
Unit #:
Parcel Number: 210314301046
Legal Description: Subdivision: VAIL INTERMOUNTAIN DEV SUB Block: 9 Lot: 16
Contacts
Contact Type: Applicant
Full Name: Gary Manchester
Address: 2794 Snowberry Vail, CO 81657 Phone: 7206708129
Contact Type: Property Owner
Full Name: MANCHESTER, GARY P. & JEANE M.
Address: Phone: None
Contact Type: Architect
Full Name: Seth Bossung
Address: 1891 Eagle Ranch Road PO Box 3835 Eagle, CO 81631 Phone: 9703066612
Contractor
Contractor Type: General
Company: Last Ridge Development Corp.
State License #: State ID No. 20141742737 Phone: 7206708129
Project Information
Project Name: Manchester Residence 2016
Project Description:
Primary unit of new wood-framed duplex (primary / secondary) residence. 2.5 stories above grade plane. 1-
hour fire separation between dwelling units. A monitored alarm and fire suppression system to be installed
per NFPA 13R.
Fees Paid
Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$7,561.50
Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$4,914.98
Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$30,486.58
Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$1,640.00
Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$410.00
Account #: 001-0000.31111.00 - Plumbing Permit Fee Fee Amount:$1,080.00
Account #: 001-0000.31123.00 - Plumbing Plan Review Fee Fee Amount:$270.00
Account #: 111-0000.31127.00 - Recreation Amenities Fee Fee Amount:$820.80
Account #: 110-23010.00 - Traffic Impact Fee Fee Amount:$6,333.00
Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00
Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00
Account #: 001-0000.31128.00 - Will Call Fee (Plumbing Scope)Fee Amount:$5.00
Total Paid:$53,531.86
Conditions
CONDITIONS UNDER WHICH PERMITS BECOME VOID:
If construction is not begun within 6 months from the date permit was issued.
If more than 5 months elapses between inspections.
If incorrect information is given on the application at the time the permit was issued.
Christopher Jarecki - Town of Vail Building Official
NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal
law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees.
Residential
Contact Information Project Assumptions
Project Number
Project Quote
Project Name
Designed For
.1
Last Ridge Snowberry Duplex
South
VAIL, CO (Colorado)
Designed By Brent Hettinger
Company Name George T. Sanders Company
Phone Number 970-468-8254
Outdoor Temp -21 °F
Elevation 8200 ft
Wind Speed 10 mph
Job Type
Project Information
Pump Specs
Zone Name Flow Head Delta T Supply Fluid Temp
Zone 1 2.1 GPM 2.1 ft 20 105 °F
Zone 2 1 GPM 1.1 ft 20 105 °F
Zone 3 1.3 GPM 1.2 ft 20 110 °F
Zone 4 0.4 GPM 0.2 ft 20 120 °F
Zone 5 0.7 GPM 1.4 ft 20 120 °F
Zone 6 0.5 GPM 0.3 ft 20 120 °F
Zone 7 0.2 GPM 0.2 ft 20 95 °F
Zone 8 2.7 GPM 1.6 ft 20 120 °F
Zone 9 1 GPM 1.3 ft 20 120 °F
Zone 10 0.3 GPM 0.3 ft 20 95 °F
Copyright(c) Watts Radiant 2008 Page 1 of 4Last Ridge Snowberry Duplex S..rad
2/16/2018RadiantWorks Professional Mechanical Summary Report
Heated Area Descriptions
Application Construction Heated Area Product Totals
Zone 1 <> Room List (Garage)
Radiant Heating Slab
None
1126 ft² (5) 250' Lengths of 1/2"
RadiantPEX+
Zone 2 <> Room List (Entry Hall,Mud, Gear Storage)
Radiant Heating Slab
None
509 ft² (3) 200' Lengths of 1/2"
RadiantPEX+
Zone 3 <> Room List (Family, Pwdr, Lndry,Storage)
Radiant Heating ThinSlab
None
882 ft² (4) 250' Lengths of 1/2"
RadiantPEX+
Zone 4 <> Room List (S.E. Bed, Clst, Bath)
Radiant Heating ThinSlab
None
323 ft² (2) 175' Lengths of 1/2"
RadiantPEX+
Zone 5 <> Room List (S.W. Bed, Clst, Bath)
Radiant Heating ThinSlab
None
454 ft² (2) 250' Lengths of 1/2"
RadiantPEX+
Zone 6 <> Room List (Jr Master, Clst)
Radiant Heating ThinSlab
None
348 ft² (2) 200' Lengths of 1/2"
RadiantPEX+
Zone 7 <> Room List (2nd Master Bath)
Radiant Heating ThinSlab
None
111 ft² (1) 125' Lengths of 1/2"
RadiantPEX+
Zone 8 <> Room List (Living,Kit,Din, Pwdr, Hall)
Radiant Heating ThinSlab
None
1057 ft² (7) 225' Lengths of 1/2"
RadiantPEX+
Zone 9 <> Room List (M.Bed, Clst)
Radiant Heating ThinSlab
None
499 ft² (3) 250' Lengths of 1/2"
RadiantPEX+
Zone 10 <> Room List (M. Bath)
Radiant Heating ThinSlab
None
140 ft² (1) 150' Lengths of 1/2"
RadiantPEX+
Heating Load Summary
Tube
Spacing
(in)
Intensity
(BTU/h·ft²)
Back/Edge
Losses
(BTU/h·ft²)
Total
Required
(BTU/h)
Total
Provided
(BTU/h)
Supp.
Needed
Zone 1 18052 39448
Garage 12 16.03 2.79 18052 39448
Copyright(c) Watts Radiant 2008 Page 2 of 4Last Ridge Snowberry Duplex S..rad
2/16/2018RadiantWorks Professional Mechanical Summary Report
10.2 GPM
2.1 ft
102289 BTU/h
66 Gallons
5449 ft²
Project Summary
Total Flow:
Total System Head:
Boiler Load:
Total System Volume:
Total Heated Area:
Please verify all project information for accuracy.
Zone 2 7948 15402
Entry Hall,Mud 12 18.52 2.86 4668 7377
Gear Storage 12 12.76 5.16 3280 8025
Zone 3 12037 22331
Family 12 13.93 0.85 8876 12908
Pwdr 12 6.41 0.73 192 1038
Lndry,Storage 12 13.81 0.78 2969 8385
Zone 4 3757 9406
S.E. Bed 12 12.06 0.95 2351 4688
Clst 12 6.41 0.73 397 1413
Bath 12 15.29 1.02 1009 3305
Zone 5 6576 13383
S.W. Bed 12 15.2 1.04 4606 7686
Clst 12 10.6 0.96 636 1367
Bath 12 14.66 1.04 1334 4330
Zone 6 4525 8672
Jr Master 12 14.38 1.00 4141 7305
Clst 12 6.41 0.73 384 1367
Zone 7 2104 2652
2nd Master Bath 12 18.96 0.50 2104 2652
Zone 8 25969 30912
Living,Kit,Din 8 25.22 1.44 21491 24358
Pwdr 12 19.1 1.07 955 2509
Hall 12 22.73 1.37 3523 4045
Zone 9 9523 12524
M.Bed 8 24.75 1.52 8118 8644
Clst 12 8.22 0.82 1405 3880
Zone 10 2523 3341
M. Bath 12 18.02 0.48 2523 3341
Copyright(c) Watts Radiant 2008 Page 3 of 4Last Ridge Snowberry Duplex S..rad
2/16/2018RadiantWorks Professional Mechanical Summary Report
Signature: Date:
Copyright(c) Watts Radiant 2008 Page 4 of 4Last Ridge Snowberry Duplex S..rad
2/16/2018RadiantWorks Professional Mechanical Summary Report
Generated by REScheck-Web Software
Compliance Certificate
Project Manchester Snowberry Duplex
Energy Code: 2015 IECC
Location: Vail, Colorado
Construction Type: Single-family
Project Type: New Construction
Orientation: Bldg. faces 0 deg. from North
Conditioned Floor Area: 9,280 ft2
Glazing Area 24%
Climate Zone: 6 (9248 HDD)
Permit Date:
Construction Site:
2794 Snowberry Drive
Vail, CO 81657
Owner/Agent:
Gary Manchester
Last Ridge Development
1720 Wazee, Unit 5D
Denver, CO 80202
(720) 670-8129
garymanchester@haselden.com
Designer/Contractor:
Seth Bossung
Intention Architecture
1891 Eagle Ranch Road
Eagle, Colorado 81631
seth@intentionarchitecture.com
Permit Number:
Compliance: Passes using UA trade-off
7.0% Better Than Code Maximum UA: 1657 Your UA: 1541
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Ceiling: Cathedral Ceiling (no attic) 4,375 56.0 21.0 0.013 57
NORTH WALL TOTAL EXPOSED: Wood Frame, 24" o.c.
Orientation: Front
2,791 23.0 0.0 0.053 110
Solid Doors: Solid Door (under 50% glazing)
Orientation: Front
170 0.210 36
Door: Glass Door (over 50% glazing)
Orientation: Front
26 0.230 6
WINDOWS: Wood Frame
Orientation: Front
526 0.290 153
WEST WALL TOTAL EXPOSED: Wood Frame, 24" o.c.
Orientation: Right side
3,352 23.0 0.0 0.053 130
Door: Solid Door (under 50% glazing)
Orientation: Right side
152 0.210 32
Door: Glass Door (over 50% glazing)
Orientation: Right side
33 0.230 8
Window: Wood Frame
Orientation: Right side
708 0.290 205
SOUTH WALL TOTAL EXPOSED: Wood Frame, 24" o.c.
Orientation: Back
1,934 23.0 0.0 0.053 73
Window: Wood Frame
Orientation: Back
561 0.290 163
Project Title: Manchester Snowberry Duplex
Data filename: Page 1 of10
04/07/18Report date:
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
EAST WALL TOTAL EXPOSED: Wood Frame, 24" o.c.
Orientation: Left side
1,459 23.0 0.0 0.053 56
Window: Wood Frame
Orientation: Left side
393 0.290 114
CRAWLSPACE FLOOR: All-Wood Joist/Truss 437 30.0 0.0 0.033 14
FIRST FLOOR SLAB ON GRADE: Slab-On-Grade (Heated)
Insulation depth: 2.0'
411 10.0 0.767 315
North Basement: Solid Concrete or Masonry
Orientation: Front
Wall height: 10.0'
Depth below grade: 9.0'
Insulation depth: 10.0'
601 23.0 10.0 0.029 17
West Basement: Solid Concrete or Masonry
Orientation: Right side
Wall height: 10.0'
Depth below grade: 10.0'
Insulation depth: 10.0'
93 23.0 10.0 0.027 3
South Basement: Solid Concrete or Masonry
Orientation: Back
Wall height: 10.0'
Depth below grade: 10.0'
Insulation depth: 10.0'
1,666 23.0 10.0 0.027 45
Crawlspace Wall: Solid Concrete or Masonry
Wall height: 7.0'
Depth below grade: 4.0'
Insulation depth: 5.0'
124 10.0 10.0 0.050 4
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: Manchester Snowberry Duplex
Data filename: Page 2 of10
04/07/18Report date:
Inspection Checklist
Requirements: 41.0% were addressed directly in the REScheck software
REScheck Software Version : REScheck-Web
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2015 IECC
Section
#
& Req.ID
Pre-Inspection/Plan Review Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
103.1,
103.2
[PR1]1
Construction drawings and
documentation demonstrate
energy code compliance for the
building envelope. Thermal
envelope represented on
construction documents.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec:
A0.1, BUILDING SECTIONS
AND DETAILS
103.1,
103.2,
403.7
[PR3]1
Construction drawings and
documentation demonstrate
energy code compliance for
lighting and mechanical systems.
Systems serving multiple
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
Complies
Does Not
Not Observable
Not Applicable
302.1,
403.7
[PR2]2
Heating and cooling equipment is
sized per ACCA Manual S based
on loads calculated per ACCA
Manual J or other methods
approved by the code official.
Heating:
Btu/hr_____
Cooling:
Btu/hr_____
Heating:
Btu/hr_____
Cooling:
Btu/hr_____
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Manchester Snowberry Duplex
Data filename: Page 3 of10
04/07/18Report date:
Section
#
& Req.ID
Foundation Inspection Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
402.1.2
[FO1]1
Slab edge insulation R-value. R-_____
Unheated
Heated
R-_____
Unheated
Heated
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.2
[FO3]1
Slab edge insulation
depth/length.
_____ ft _____ ft Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.1
[FO4]1
Conditioned basement wall
insulation R-value. Where interior
insulation is used, verification
may need to occur during
Insulation Inspection. Not
required in warm-humid locations
in Climate Zone 3.
R-_____
R-_____
R-_____
R-_____
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2
[FO5]1
Conditioned basement wall
insulation installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec:
A5.1
402.2.9
[FO6]1
Conditioned basement wall
insulation depth of burial or
distance from top of wall.
_____ ft _____ ft Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.2.11
[FO7]1
Unvented crawl space wall
insulation R-value.
R-_____
R-_____
R-_____
R-_____
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2
[FO8]1
Unvented crawl space wall
insulation installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
402.2.11
[FO9]1
Unvented crawl space continuous
vapor retarder installed over
exposed earth, joints overlapped
by 6 in. and sealed, extending at
least 6 in. up and attached to the
wall.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec:
A2.1
402.2.11
[FO10]1
Unvented crawl space wall
insulation depth of burial or
distance from top of wall.
_____ in. _____ in. Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2.1
[FO11]2
A protective covering is installed
to protect exposed exterior
insulation and extends a
minimum of 6 in. below grade.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement is
not applicable.
403.9
[FO12]2
Snow- and ice-melting system
controls installed.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Manchester Snowberry Duplex
Data filename: Page 4 of10
04/07/18Report date:
Section
#
& Req.ID
Framing / Rough-In Inspection Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
402.1.1,
402.3.4
[FR1]1
Door U-factor. U-_____ U-_____ Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.1,
402.3.1,
402.3.3,
402.5
[FR2]1
Glazing U-factor (area-weighted
average).
U-_____ U-_____ Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.1.3
[FR4]1
U-factors of fenestration products
are determined in accordance
with the NFRC test procedure or
taken from the default table.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
402.4.1.1
[FR23]1
Air barrier and thermal barrier
installed per manufacturer’s
instructions.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec:
A0.1, A5.2
402.4.3
[FR20]1
Fenestration that is not site built
is listed and labeled as meeting
AAMA /WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC
400 that do not exceed code
limits.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
402.4.5
[FR16]2
IC-rated recessed lighting fixtures
sealed at housing/interior finish
and labeled to indicate ≤2.0 cfm
leakage at 75 Pa.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
403.3.1
[FR12]1
Supply and return ducts in attics
insulated >= R-8 where duct is
>= 3 inches in diameter and >=
R-6 where < 3 inches. Supply and
return ducts in other portions of
the building insulated >= R-6 for
diameter >= 3 inches and R-4.2
for < 3 inches in diameter.
Complies
Does Not
Not Observable
Not Applicable
403.3.5
[FR15]3
Building cavities are not used as
ducts or plenums.
Complies
Does Not
Not Observable
Not Applicable
403.4
[FR17]2
HVAC piping conveying fluids
above 105 ºF or chilled fluids
below 55 ºF are insulated to ≥R-
3.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
403.4.1
[FR24]1
Protection of insulation on HVAC
piping.
Complies
Does Not
Not Observable
Not Applicable
403.5.3
[FR18]2
Hot water pipes are insulated to
≥R-3.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
403.6
[FR19]2
Automatic or gravity dampers are
installed on all outdoor air
intakes and exhausts.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec:
A0.1
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Manchester Snowberry Duplex
Data filename: Page 5 of10
04/07/18Report date:
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Manchester Snowberry Duplex
Data filename: Page 6 of10
04/07/18Report date:
Section
#
& Req.ID
Insulation Inspection Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
303.1
[IN13]2
All installed insulation is labeled
or the installed R-values
provided.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
402.1.1,
402.2.6
[IN1]1
Floor insulation R-value. R-_____
Wood
Steel
R-_____
Wood
Steel
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2,
402.2.7
[IN2]1
Floor insulation installed per
manufacturer’s instructions and
in substantial contact with the
underside of the subfloor, or floor
framing cavity insulation is in
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec:
BUILDING SECTIONS/DETAILS
402.1.1,
402.2.5,
402.2.6
[IN3]1
Wall insulation R-value. If this is a
mass wall with at least ½ of the
wall insulation on the wall
exterior, the exterior insulation
requirement applies (FR10).
R-_____
Wood
Mass
Steel
R-_____
Wood
Mass
Steel
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2
[IN4]1
Wall insulation is installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec:
A5.2
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Manchester Snowberry Duplex
Data filename: Page 7 of10
04/07/18Report date:
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
402.1.1,
402.2.1,
402.2.2,
402.2.6
[FI1]1
Ceiling insulation R-value. R-_____
Wood
Steel
R-_____
Wood
Steel
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.1.1.1,
303.2
[FI2]1
Ceiling insulation installed per
manufacturer’s instructions.
Blown insulation marked every
300 ft².
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec:
A5.2
402.2.3
[FI22]2
Vented attics with air permeable
insulation include baffle adjacent
to soffit and eave vents that
extends over insulation.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement is
not applicable.
402.2.4
[FI3]1
Attic access hatch and door
insulation ≥R-value of the
adjacent assembly.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec:
NOTAPPLICABLE
402.4.1.2
[FI17]1
Blower door test @ 50 Pa. <=5
ach in Climate Zones 1-2, and
<=3 ach in Climate Zones 3-8.
ACH 50 =_____ ACH 50 =_____ Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec:
A0.1
403.3.4
[FI4]1
Duct tightness test result of <=4
cfm/100 ft2 across the system or
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in
tests, verification may need to
occur during Framing Inspection.
_____ cfm/100
ft2
_____ cfm/100
ft2
Complies
Does Not
Not Observable
Not Applicable
403.3.3
[FI27]1
Ducts are pressure tested to
determine air leakage with
either: Rough-in test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the system including
the manufacturer’s air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer’s air
handler enclosure.
_____ cfm/100
ft2
_____ cfm/100
ft2
Complies
Does Not
Not Observable
Not Applicable
403.3.2.1
[FI24]1
Air handler leakage designated
by manufacturer at <=2% of
design air flow.
Complies
Does Not
Not Observable
Not Applicable
403.1.1
[FI9]2
Programmable thermostats
installed for control of primary
heating and cooling systems and
initially set by manufacturer to
code specifications.
Complies
Does Not
Not Observable
Not Applicable
403.1.2
[FI10]2
Heat pump thermostat installed
on heat pumps.
Complies
Does Not
Not Observable
Not Applicable
403.5.1
[FI11]2
Circulating service hot water
systems have automatic or
accessible manual controls.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Manchester Snowberry Duplex
Data filename: Page 8 of10
04/07/18Report date:
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
403.6.1
[FI25]2
All mechanical ventilation system
fans not part of tested and listed
HVAC equipment meet efficacy
and air flow limits.
Complies
Does Not
Not Observable
Not Applicable
403.2
[FI26]2
Hot water boilers supplying heat
through one- or two-pipe heating
systems have outdoor setback
control to lower boiler water
temperature based on outdoor
temperature.
Complies
Does Not
Not Observable
Not Applicable
403.5.1.1
[FI28]2
Heated water circulation systems
have a circulation pump. The
system return pipe is a dedicated
return pipe or a cold water supply
pipe. Gravity and thermos-
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
Complies
Does Not
Not Observable
Not Applicable
403.5.1.2
[FI29]2
Electric heat trace systems
comply with IEEE 515.1 or UL
515. Controls automatically
adjust the energy input to the
heat tracing to maintain the
desired water temperature in the
piping.
Complies
Does Not
Not Observable
Not Applicable
403.5.2
[FI30]2
Water distribution systems that
have recirculation pumps that
pump water from a heated water
supply pipe back to the heated
water source through a cold
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104ºF.
Complies
Does Not
Not Observable
Not Applicable
403.5.4
[FI31]2
Drain water heat recovery units
tested in accordance with CSA
B55.1. Potable water-side
pressure loss of drain water heat
recovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
Complies
Does Not
Not Observable
Not Applicable
404.1
[FI6]1
75% of lamps in permanent
fixtures or 75% of permanent
fixtures have high efficacy lamps.
Does not apply to low-voltage
lighting.
Complies
Does Not
Not Observable
Not Applicable
404.1.1
[FI23]3
Fuel gas lighting systems have
no continuous pilot light.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Manchester Snowberry Duplex
Data filename: Page 9 of10
04/07/18Report date:
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
401.3
[FI7]2
Compliance certificate posted. Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
303.3
[FI18]3
Manufacturer manuals for
mechanical and water heating
systems have been provided.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Manchester Snowberry Duplex
Data filename: Page 10 of10
04/07/18Report date:
2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
23.00Above-Grade Wall
33.00Below-Grade Wall
30.00Floor
77.00Ceiling / Roof
_______Ductwork (unconditioned spaces):
Glass & Door Rating SHGCU-Factor
0.29Window
0.21Door
Heating & Cooling Equipment Efficiency
_______Heating System:_________________________
_______Cooling System:_________________________
_______Water Heater:___________________________
Name: Date:
Comments
Residential
Contact Information Project Assumptions
Project Number
Project Quote
Project Name
Designed For
.1
Last Ridge Snowberry Duplex
South
VAIL, CO (Colorado)
Designed By Brent Hettinger
Company Name George T. Sanders Company
Phone Number 970-468-8254
Outdoor Temp -21 °F
Elevation 8200 ft
Wind Speed 10 mph
Job Type
Project Information
Pump Specs
Zone Name Flow Head Delta T Supply Fluid Temp
Zone 1 2.1 GPM 2.1 ft 20 105 °F
Zone 2 1 GPM 1.1 ft 20 105 °F
Zone 3 1.3 GPM 1.2 ft 20 110 °F
Zone 4 0.4 GPM 0.2 ft 20 120 °F
Zone 5 0.7 GPM 1.4 ft 20 120 °F
Zone 6 0.5 GPM 0.3 ft 20 120 °F
Zone 7 0.2 GPM 0.2 ft 20 95 °F
Zone 8 2.7 GPM 1.6 ft 20 120 °F
Zone 9 1 GPM 1.3 ft 20 120 °F
Zone 10 0.3 GPM 0.3 ft 20 95 °F
Copyright(c) Watts Radiant 2008 Page 1 of 4Last Ridge Snowberry Duplex S..rad
2/16/2018RadiantWorks Professional Mechanical Summary Report
Heated Area Descriptions
Application Construction Heated Area Product Totals
Zone 1 <> Room List (Garage)
Radiant Heating Slab
None
1126 ft² (5) 250' Lengths of 1/2"
RadiantPEX+
Zone 2 <> Room List (Entry Hall,Mud, Gear Storage)
Radiant Heating Slab
None
509 ft² (3) 200' Lengths of 1/2"
RadiantPEX+
Zone 3 <> Room List (Family, Pwdr, Lndry,Storage)
Radiant Heating ThinSlab
None
882 ft² (4) 250' Lengths of 1/2"
RadiantPEX+
Zone 4 <> Room List (S.E. Bed, Clst, Bath)
Radiant Heating ThinSlab
None
323 ft² (2) 175' Lengths of 1/2"
RadiantPEX+
Zone 5 <> Room List (S.W. Bed, Clst, Bath)
Radiant Heating ThinSlab
None
454 ft² (2) 250' Lengths of 1/2"
RadiantPEX+
Zone 6 <> Room List (Jr Master, Clst)
Radiant Heating ThinSlab
None
348 ft² (2) 200' Lengths of 1/2"
RadiantPEX+
Zone 7 <> Room List (2nd Master Bath)
Radiant Heating ThinSlab
None
111 ft² (1) 125' Lengths of 1/2"
RadiantPEX+
Zone 8 <> Room List (Living,Kit,Din, Pwdr, Hall)
Radiant Heating ThinSlab
None
1057 ft² (7) 225' Lengths of 1/2"
RadiantPEX+
Zone 9 <> Room List (M.Bed, Clst)
Radiant Heating ThinSlab
None
499 ft² (3) 250' Lengths of 1/2"
RadiantPEX+
Zone 10 <> Room List (M. Bath)
Radiant Heating ThinSlab
None
140 ft² (1) 150' Lengths of 1/2"
RadiantPEX+
Heating Load Summary
Tube
Spacing
(in)
Intensity
(BTU/h·ft²)
Back/Edge
Losses
(BTU/h·ft²)
Total
Required
(BTU/h)
Total
Provided
(BTU/h)
Supp.
Needed
Zone 1 18052 39448
Garage 12 16.03 2.79 18052 39448
Copyright(c) Watts Radiant 2008 Page 2 of 4Last Ridge Snowberry Duplex S..rad
2/16/2018RadiantWorks Professional Mechanical Summary Report
10.2 GPM
2.1 ft
102289 BTU/h
66 Gallons
5449 ft²
Project Summary
Total Flow:
Total System Head:
Boiler Load:
Total System Volume:
Total Heated Area:
Please verify all project information for accuracy.
Zone 2 7948 15402
Entry Hall,Mud 12 18.52 2.86 4668 7377
Gear Storage 12 12.76 5.16 3280 8025
Zone 3 12037 22331
Family 12 13.93 0.85 8876 12908
Pwdr 12 6.41 0.73 192 1038
Lndry,Storage 12 13.81 0.78 2969 8385
Zone 4 3757 9406
S.E. Bed 12 12.06 0.95 2351 4688
Clst 12 6.41 0.73 397 1413
Bath 12 15.29 1.02 1009 3305
Zone 5 6576 13383
S.W. Bed 12 15.2 1.04 4606 7686
Clst 12 10.6 0.96 636 1367
Bath 12 14.66 1.04 1334 4330
Zone 6 4525 8672
Jr Master 12 14.38 1.00 4141 7305
Clst 12 6.41 0.73 384 1367
Zone 7 2104 2652
2nd Master Bath 12 18.96 0.50 2104 2652
Zone 8 25969 30912
Living,Kit,Din 8 25.22 1.44 21491 24358
Pwdr 12 19.1 1.07 955 2509
Hall 12 22.73 1.37 3523 4045
Zone 9 9523 12524
M.Bed 8 24.75 1.52 8118 8644
Clst 12 8.22 0.82 1405 3880
Zone 10 2523 3341
M. Bath 12 18.02 0.48 2523 3341
Copyright(c) Watts Radiant 2008 Page 3 of 4Last Ridge Snowberry Duplex S..rad
2/16/2018RadiantWorks Professional Mechanical Summary Report
Signature: Date:
Copyright(c) Watts Radiant 2008 Page 4 of 4Last Ridge Snowberry Duplex S..rad
2/16/2018RadiantWorks Professional Mechanical Summary Report