Loading...
HomeMy WebLinkAboutB18-0090_B18-0090 Permit Documents_1526591042.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Construction B18-0090 Issued: 05/17/2018 TOWN OF VAIL Property Information Address: 2794 SNOWBERRY DR (210314301046) ( 210314301046 ) Unit #: Parcel Number: 210314301046 Legal Description: Subdivision: VAIL INTERMOUNTAIN DEV SUB Block: 9 Lot: 16 Contacts Contact Type: Applicant Full Name: Gary Manchester Address: 2794 Snowberry Vail, CO 81657 Phone: 7206708129 Contact Type: Property Owner Full Name: MANCHESTER, GARY P. & JEANE M. Address: Phone: None Contact Type: Architect Full Name: Seth Bossung Address: 1891 Eagle Ranch Road PO Box 3835 Eagle, CO 81631 Phone: 9703066612 Contractor Contractor Type: General Company: Last Ridge Development Corp. State License #: State ID No. 20141742737 Phone: 7206708129 Project Information Project Name: Manchester Residence 2016 Project Description: Primary unit of new wood-framed duplex (primary / secondary) residence. 2.5 stories above grade plane. 1- hour fire separation between dwelling units. A monitored alarm and fire suppression system to be installed per NFPA 13R. Fees Paid Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$7,561.50 Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$4,914.98 Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$30,486.58 Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$1,640.00 Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$410.00 Account #: 001-0000.31111.00 - Plumbing Permit Fee Fee Amount:$1,080.00 Account #: 001-0000.31123.00 - Plumbing Plan Review Fee Fee Amount:$270.00 Account #: 111-0000.31127.00 - Recreation Amenities Fee Fee Amount:$820.80 Account #: 110-23010.00 - Traffic Impact Fee Fee Amount:$6,333.00 Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Plumbing Scope)Fee Amount:$5.00 Total Paid:$53,531.86 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. Residential Contact Information Project Assumptions Project Number Project Quote Project Name Designed For .1 Last Ridge Snowberry Duplex South VAIL, CO (Colorado) Designed By Brent Hettinger Company Name George T. Sanders Company Phone Number 970-468-8254 Outdoor Temp -21 °F Elevation 8200 ft Wind Speed 10 mph Job Type Project Information Pump Specs Zone Name Flow Head Delta T Supply Fluid Temp Zone 1 2.1 GPM 2.1 ft 20 105 °F Zone 2 1 GPM 1.1 ft 20 105 °F Zone 3 1.3 GPM 1.2 ft 20 110 °F Zone 4 0.4 GPM 0.2 ft 20 120 °F Zone 5 0.7 GPM 1.4 ft 20 120 °F Zone 6 0.5 GPM 0.3 ft 20 120 °F Zone 7 0.2 GPM 0.2 ft 20 95 °F Zone 8 2.7 GPM 1.6 ft 20 120 °F Zone 9 1 GPM 1.3 ft 20 120 °F Zone 10 0.3 GPM 0.3 ft 20 95 °F Copyright(c) Watts Radiant 2008 Page 1 of 4Last Ridge Snowberry Duplex S..rad 2/16/2018RadiantWorks Professional Mechanical Summary Report Heated Area Descriptions Application Construction Heated Area Product Totals Zone 1 <> Room List (Garage) Radiant Heating Slab None 1126 ft² (5) 250' Lengths of 1/2" RadiantPEX+ Zone 2 <> Room List (Entry Hall,Mud, Gear Storage) Radiant Heating Slab None 509 ft² (3) 200' Lengths of 1/2" RadiantPEX+ Zone 3 <> Room List (Family, Pwdr, Lndry,Storage) Radiant Heating ThinSlab None 882 ft² (4) 250' Lengths of 1/2" RadiantPEX+ Zone 4 <> Room List (S.E. Bed, Clst, Bath) Radiant Heating ThinSlab None 323 ft² (2) 175' Lengths of 1/2" RadiantPEX+ Zone 5 <> Room List (S.W. Bed, Clst, Bath) Radiant Heating ThinSlab None 454 ft² (2) 250' Lengths of 1/2" RadiantPEX+ Zone 6 <> Room List (Jr Master, Clst) Radiant Heating ThinSlab None 348 ft² (2) 200' Lengths of 1/2" RadiantPEX+ Zone 7 <> Room List (2nd Master Bath) Radiant Heating ThinSlab None 111 ft² (1) 125' Lengths of 1/2" RadiantPEX+ Zone 8 <> Room List (Living,Kit,Din, Pwdr, Hall) Radiant Heating ThinSlab None 1057 ft² (7) 225' Lengths of 1/2" RadiantPEX+ Zone 9 <> Room List (M.Bed, Clst) Radiant Heating ThinSlab None 499 ft² (3) 250' Lengths of 1/2" RadiantPEX+ Zone 10 <> Room List (M. Bath) Radiant Heating ThinSlab None 140 ft² (1) 150' Lengths of 1/2" RadiantPEX+ Heating Load Summary Tube Spacing (in) Intensity (BTU/h·ft²) Back/Edge Losses (BTU/h·ft²) Total Required (BTU/h) Total Provided (BTU/h) Supp. Needed Zone 1 18052 39448 Garage 12 16.03 2.79 18052 39448 Copyright(c) Watts Radiant 2008 Page 2 of 4Last Ridge Snowberry Duplex S..rad 2/16/2018RadiantWorks Professional Mechanical Summary Report 10.2 GPM 2.1 ft 102289 BTU/h 66 Gallons 5449 ft² Project Summary Total Flow: Total System Head: Boiler Load: Total System Volume: Total Heated Area: Please verify all project information for accuracy. Zone 2 7948 15402 Entry Hall,Mud 12 18.52 2.86 4668 7377 Gear Storage 12 12.76 5.16 3280 8025 Zone 3 12037 22331 Family 12 13.93 0.85 8876 12908 Pwdr 12 6.41 0.73 192 1038 Lndry,Storage 12 13.81 0.78 2969 8385 Zone 4 3757 9406 S.E. Bed 12 12.06 0.95 2351 4688 Clst 12 6.41 0.73 397 1413 Bath 12 15.29 1.02 1009 3305 Zone 5 6576 13383 S.W. Bed 12 15.2 1.04 4606 7686 Clst 12 10.6 0.96 636 1367 Bath 12 14.66 1.04 1334 4330 Zone 6 4525 8672 Jr Master 12 14.38 1.00 4141 7305 Clst 12 6.41 0.73 384 1367 Zone 7 2104 2652 2nd Master Bath 12 18.96 0.50 2104 2652 Zone 8 25969 30912 Living,Kit,Din 8 25.22 1.44 21491 24358 Pwdr 12 19.1 1.07 955 2509 Hall 12 22.73 1.37 3523 4045 Zone 9 9523 12524 M.Bed 8 24.75 1.52 8118 8644 Clst 12 8.22 0.82 1405 3880 Zone 10 2523 3341 M. Bath 12 18.02 0.48 2523 3341 Copyright(c) Watts Radiant 2008 Page 3 of 4Last Ridge Snowberry Duplex S..rad 2/16/2018RadiantWorks Professional Mechanical Summary Report Signature: Date: Copyright(c) Watts Radiant 2008 Page 4 of 4Last Ridge Snowberry Duplex S..rad 2/16/2018RadiantWorks Professional Mechanical Summary Report Generated by REScheck-Web Software Compliance Certificate Project Manchester Snowberry Duplex Energy Code: 2015 IECC Location: Vail, Colorado Construction Type: Single-family Project Type: New Construction Orientation: Bldg. faces 0 deg. from North Conditioned Floor Area: 9,280 ft2 Glazing Area 24% Climate Zone: 6 (9248 HDD) Permit Date: Construction Site: 2794 Snowberry Drive Vail, CO 81657 Owner/Agent: Gary Manchester Last Ridge Development 1720 Wazee, Unit 5D Denver, CO 80202 (720) 670-8129 garymanchester@haselden.com Designer/Contractor: Seth Bossung Intention Architecture 1891 Eagle Ranch Road Eagle, Colorado 81631 seth@intentionarchitecture.com Permit Number: Compliance: Passes using UA trade-off 7.0% Better Than Code Maximum UA: 1657 Your UA: 1541 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Ceiling: Cathedral Ceiling (no attic) 4,375 56.0 21.0 0.013 57 NORTH WALL TOTAL EXPOSED: Wood Frame, 24" o.c. Orientation: Front 2,791 23.0 0.0 0.053 110 Solid Doors: Solid Door (under 50% glazing) Orientation: Front 170 0.210 36 Door: Glass Door (over 50% glazing) Orientation: Front 26 0.230 6 WINDOWS: Wood Frame Orientation: Front 526 0.290 153 WEST WALL TOTAL EXPOSED: Wood Frame, 24" o.c. Orientation: Right side 3,352 23.0 0.0 0.053 130 Door: Solid Door (under 50% glazing) Orientation: Right side 152 0.210 32 Door: Glass Door (over 50% glazing) Orientation: Right side 33 0.230 8 Window: Wood Frame Orientation: Right side 708 0.290 205 SOUTH WALL TOTAL EXPOSED: Wood Frame, 24" o.c. Orientation: Back 1,934 23.0 0.0 0.053 73 Window: Wood Frame Orientation: Back 561 0.290 163 Project Title: Manchester Snowberry Duplex Data filename: Page 1 of10 04/07/18Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA EAST WALL TOTAL EXPOSED: Wood Frame, 24" o.c. Orientation: Left side 1,459 23.0 0.0 0.053 56 Window: Wood Frame Orientation: Left side 393 0.290 114 CRAWLSPACE FLOOR: All-Wood Joist/Truss 437 30.0 0.0 0.033 14 FIRST FLOOR SLAB ON GRADE: Slab-On-Grade (Heated) Insulation depth: 2.0' 411 10.0 0.767 315 North Basement: Solid Concrete or Masonry Orientation: Front Wall height: 10.0' Depth below grade: 9.0' Insulation depth: 10.0' 601 23.0 10.0 0.029 17 West Basement: Solid Concrete or Masonry Orientation: Right side Wall height: 10.0' Depth below grade: 10.0' Insulation depth: 10.0' 93 23.0 10.0 0.027 3 South Basement: Solid Concrete or Masonry Orientation: Back Wall height: 10.0' Depth below grade: 10.0' Insulation depth: 10.0' 1,666 23.0 10.0 0.027 45 Crawlspace Wall: Solid Concrete or Masonry Wall height: 7.0' Depth below grade: 4.0' Insulation depth: 5.0' 124 10.0 10.0 0.050 4 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: Manchester Snowberry Duplex Data filename: Page 2 of10 04/07/18Report date: Inspection Checklist Requirements: 41.0% were addressed directly in the REScheck software REScheck Software Version : REScheck-Web Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Pre-Inspection/Plan Review Plans Verified Value Field Verified Value Complies? Comments/Assumptions 103.1, 103.2 [PR1]1 Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: A0.1, BUILDING SECTIONS AND DETAILS 103.1, 103.2, 403.7 [PR3]1 Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. Complies Does Not Not Observable Not Applicable 302.1, 403.7 [PR2]2 Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_____ Cooling: Btu/hr_____ Heating: Btu/hr_____ Cooling: Btu/hr_____ Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Manchester Snowberry Duplex Data filename: Page 3 of10 04/07/18Report date: Section # & Req.ID Foundation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 402.1.2 [FO1]1 Slab edge insulation R-value. R-_____ Unheated Heated R-_____ Unheated Heated Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.2 [FO3]1 Slab edge insulation depth/length. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1 [FO4]1 Conditioned basement wall insulation R-value. Where interior insulation is used, verification may need to occur during Insulation Inspection. Not required in warm-humid locations in Climate Zone 3. R-_____ R-_____ R-_____ R-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [FO5]1 Conditioned basement wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: A5.1 402.2.9 [FO6]1 Conditioned basement wall insulation depth of burial or distance from top of wall. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.2.11 [FO7]1 Unvented crawl space wall insulation R-value. R-_____ R-_____ R-_____ R-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [FO8]1 Unvented crawl space wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable 402.2.11 [FO9]1 Unvented crawl space continuous vapor retarder installed over exposed earth, joints overlapped by 6 in. and sealed, extending at least 6 in. up and attached to the wall. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: A2.1 402.2.11 [FO10]1 Unvented crawl space wall insulation depth of burial or distance from top of wall. _____ in. _____ in. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2.1 [FO11]2 A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.9 [FO12]2 Snow- and ice-melting system controls installed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Manchester Snowberry Duplex Data filename: Page 4 of10 04/07/18Report date: Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 402.1.1, 402.3.4 [FR1]1 Door U-factor. U-_____ U-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1, 402.3.1, 402.3.3, 402.5 [FR2]1 Glazing U-factor (area-weighted average). U-_____ U-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.3 [FR4]1 U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.1.1 [FR23]1 Air barrier and thermal barrier installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: A0.1, A5.2 402.4.3 [FR20]1 Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.5 [FR16]2 IC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate ≤2.0 cfm leakage at 75 Pa. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.3.1 [FR12]1 Supply and return ducts in attics insulated >= R-8 where duct is >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. Complies Does Not Not Observable Not Applicable 403.3.5 [FR15]3 Building cavities are not used as ducts or plenums. Complies Does Not Not Observable Not Applicable 403.4 [FR17]2 HVAC piping conveying fluids above 105 ºF or chilled fluids below 55 ºF are insulated to ≥R- 3. R-_____ R-_____ Complies Does Not Not Observable Not Applicable 403.4.1 [FR24]1 Protection of insulation on HVAC piping. Complies Does Not Not Observable Not Applicable 403.5.3 [FR18]2 Hot water pipes are insulated to ≥R-3. R-_____ R-_____ Complies Does Not Not Observable Not Applicable 403.6 [FR19]2 Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: A0.1 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Manchester Snowberry Duplex Data filename: Page 5 of10 04/07/18Report date: Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Manchester Snowberry Duplex Data filename: Page 6 of10 04/07/18Report date: Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 303.1 [IN13]2 All installed insulation is labeled or the installed R-values provided. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.1.1, 402.2.6 [IN1]1 Floor insulation R-value. R-_____ Wood Steel R-_____ Wood Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2, 402.2.7 [IN2]1 Floor insulation installed per manufacturer’s instructions and in substantial contact with the underside of the subfloor, or floor framing cavity insulation is in contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: BUILDING SECTIONS/DETAILS 402.1.1, 402.2.5, 402.2.6 [IN3]1 Wall insulation R-value. If this is a mass wall with at least ½ of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). R-_____ Wood Mass Steel R-_____ Wood Mass Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [IN4]1 Wall insulation is installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: A5.2 Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Manchester Snowberry Duplex Data filename: Page 7 of10 04/07/18Report date: Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions 402.1.1, 402.2.1, 402.2.2, 402.2.6 [FI1]1 Ceiling insulation R-value. R-_____ Wood Steel R-_____ Wood Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.1.1, 303.2 [FI2]1 Ceiling insulation installed per manufacturer’s instructions. Blown insulation marked every 300 ft². Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: A5.2 402.2.3 [FI22]2 Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 402.2.4 [FI3]1 Attic access hatch and door insulation ≥R-value of the adjacent assembly. R-_____ R-_____ Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: NOTAPPLICABLE 402.4.1.2 [FI17]1 Blower door test @ 50 Pa. <=5 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. ACH 50 =_____ ACH 50 =_____ Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: A0.1 403.3.4 [FI4]1 Duct tightness test result of <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing Inspection. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable 403.3.3 [FI27]1 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer’s air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer’s air handler enclosure. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable 403.3.2.1 [FI24]1 Air handler leakage designated by manufacturer at <=2% of design air flow. Complies Does Not Not Observable Not Applicable 403.1.1 [FI9]2 Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. Complies Does Not Not Observable Not Applicable 403.1.2 [FI10]2 Heat pump thermostat installed on heat pumps. Complies Does Not Not Observable Not Applicable 403.5.1 [FI11]2 Circulating service hot water systems have automatic or accessible manual controls. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Manchester Snowberry Duplex Data filename: Page 8 of10 04/07/18Report date: Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions 403.6.1 [FI25]2 All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits. Complies Does Not Not Observable Not Applicable 403.2 [FI26]2 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. Complies Does Not Not Observable Not Applicable 403.5.1.1 [FI28]2 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. Complies Does Not Not Observable Not Applicable 403.5.1.2 [FI29]2 Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. Complies Does Not Not Observable Not Applicable 403.5.2 [FI30]2 Water distribution systems that have recirculation pumps that pump water from a heated water supply pipe back to the heated water source through a cold water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104ºF. Complies Does Not Not Observable Not Applicable 403.5.4 [FI31]2 Drain water heat recovery units tested in accordance with CSA B55.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. Complies Does Not Not Observable Not Applicable 404.1 [FI6]1 75% of lamps in permanent fixtures or 75% of permanent fixtures have high efficacy lamps. Does not apply to low-voltage lighting. Complies Does Not Not Observable Not Applicable 404.1.1 [FI23]3 Fuel gas lighting systems have no continuous pilot light. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Manchester Snowberry Duplex Data filename: Page 9 of10 04/07/18Report date: Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions 401.3 [FI7]2 Compliance certificate posted. Complies Does Not Not Observable Not Applicable Requirement will be met. 303.3 [FI18]3 Manufacturer manuals for mechanical and water heating systems have been provided. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Manchester Snowberry Duplex Data filename: Page 10 of10 04/07/18Report date: 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value 23.00Above-Grade Wall 33.00Below-Grade Wall 30.00Floor 77.00Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.29Window 0.21Door Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name: Date: Comments Residential Contact Information Project Assumptions Project Number Project Quote Project Name Designed For .1 Last Ridge Snowberry Duplex South VAIL, CO (Colorado) Designed By Brent Hettinger Company Name George T. Sanders Company Phone Number 970-468-8254 Outdoor Temp -21 °F Elevation 8200 ft Wind Speed 10 mph Job Type Project Information Pump Specs Zone Name Flow Head Delta T Supply Fluid Temp Zone 1 2.1 GPM 2.1 ft 20 105 °F Zone 2 1 GPM 1.1 ft 20 105 °F Zone 3 1.3 GPM 1.2 ft 20 110 °F Zone 4 0.4 GPM 0.2 ft 20 120 °F Zone 5 0.7 GPM 1.4 ft 20 120 °F Zone 6 0.5 GPM 0.3 ft 20 120 °F Zone 7 0.2 GPM 0.2 ft 20 95 °F Zone 8 2.7 GPM 1.6 ft 20 120 °F Zone 9 1 GPM 1.3 ft 20 120 °F Zone 10 0.3 GPM 0.3 ft 20 95 °F Copyright(c) Watts Radiant 2008 Page 1 of 4Last Ridge Snowberry Duplex S..rad 2/16/2018RadiantWorks Professional Mechanical Summary Report Heated Area Descriptions Application Construction Heated Area Product Totals Zone 1 <> Room List (Garage) Radiant Heating Slab None 1126 ft² (5) 250' Lengths of 1/2" RadiantPEX+ Zone 2 <> Room List (Entry Hall,Mud, Gear Storage) Radiant Heating Slab None 509 ft² (3) 200' Lengths of 1/2" RadiantPEX+ Zone 3 <> Room List (Family, Pwdr, Lndry,Storage) Radiant Heating ThinSlab None 882 ft² (4) 250' Lengths of 1/2" RadiantPEX+ Zone 4 <> Room List (S.E. Bed, Clst, Bath) Radiant Heating ThinSlab None 323 ft² (2) 175' Lengths of 1/2" RadiantPEX+ Zone 5 <> Room List (S.W. Bed, Clst, Bath) Radiant Heating ThinSlab None 454 ft² (2) 250' Lengths of 1/2" RadiantPEX+ Zone 6 <> Room List (Jr Master, Clst) Radiant Heating ThinSlab None 348 ft² (2) 200' Lengths of 1/2" RadiantPEX+ Zone 7 <> Room List (2nd Master Bath) Radiant Heating ThinSlab None 111 ft² (1) 125' Lengths of 1/2" RadiantPEX+ Zone 8 <> Room List (Living,Kit,Din, Pwdr, Hall) Radiant Heating ThinSlab None 1057 ft² (7) 225' Lengths of 1/2" RadiantPEX+ Zone 9 <> Room List (M.Bed, Clst) Radiant Heating ThinSlab None 499 ft² (3) 250' Lengths of 1/2" RadiantPEX+ Zone 10 <> Room List (M. Bath) Radiant Heating ThinSlab None 140 ft² (1) 150' Lengths of 1/2" RadiantPEX+ Heating Load Summary Tube Spacing (in) Intensity (BTU/h·ft²) Back/Edge Losses (BTU/h·ft²) Total Required (BTU/h) Total Provided (BTU/h) Supp. Needed Zone 1 18052 39448 Garage 12 16.03 2.79 18052 39448 Copyright(c) Watts Radiant 2008 Page 2 of 4Last Ridge Snowberry Duplex S..rad 2/16/2018RadiantWorks Professional Mechanical Summary Report 10.2 GPM 2.1 ft 102289 BTU/h 66 Gallons 5449 ft² Project Summary Total Flow: Total System Head: Boiler Load: Total System Volume: Total Heated Area: Please verify all project information for accuracy. Zone 2 7948 15402 Entry Hall,Mud 12 18.52 2.86 4668 7377 Gear Storage 12 12.76 5.16 3280 8025 Zone 3 12037 22331 Family 12 13.93 0.85 8876 12908 Pwdr 12 6.41 0.73 192 1038 Lndry,Storage 12 13.81 0.78 2969 8385 Zone 4 3757 9406 S.E. Bed 12 12.06 0.95 2351 4688 Clst 12 6.41 0.73 397 1413 Bath 12 15.29 1.02 1009 3305 Zone 5 6576 13383 S.W. Bed 12 15.2 1.04 4606 7686 Clst 12 10.6 0.96 636 1367 Bath 12 14.66 1.04 1334 4330 Zone 6 4525 8672 Jr Master 12 14.38 1.00 4141 7305 Clst 12 6.41 0.73 384 1367 Zone 7 2104 2652 2nd Master Bath 12 18.96 0.50 2104 2652 Zone 8 25969 30912 Living,Kit,Din 8 25.22 1.44 21491 24358 Pwdr 12 19.1 1.07 955 2509 Hall 12 22.73 1.37 3523 4045 Zone 9 9523 12524 M.Bed 8 24.75 1.52 8118 8644 Clst 12 8.22 0.82 1405 3880 Zone 10 2523 3341 M. Bath 12 18.02 0.48 2523 3341 Copyright(c) Watts Radiant 2008 Page 3 of 4Last Ridge Snowberry Duplex S..rad 2/16/2018RadiantWorks Professional Mechanical Summary Report Signature: Date: Copyright(c) Watts Radiant 2008 Page 4 of 4Last Ridge Snowberry Duplex S..rad 2/16/2018RadiantWorks Professional Mechanical Summary Report