Loading...
HomeMy WebLinkAboutB18-0142_Approved Documents_1526584147.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Construction B18-0142 Issued: 05/17/2018 TOWN OF VAIL Property Information Address: 1450 BUFFEHR CREEK RD (210312102007) ( 210312102007 ) Unit #: Parcel Number: 210312102007 Legal Description: Subdivision: CLIFFSIDE Lot: 2 Contacts Contact Type: Applicant Full Name: Benno Scheidegger Address: 0429 Edwards Access Road A207 Ed, CO 81657 Phone: 9709268771 Contact Type: Property Owner Full Name: CLIFFTOP LLC Address: Phone: None Contractor Contractor Type: General Company: Vail Custom Builders State License #: Phone: 970-904-0512 Project Information Project Name: Clifftop LLC Residence 2017 Project Description: Complete Demo of an existing home and construct a new single family residence Fees Paid Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$14,514.75 Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$9,434.59 Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$68,600.00 Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$2,900.00 Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$725.00 Account #: 001-0000.31111.00 - Plumbing Permit Fee Fee Amount:$1,290.00 Account #: 001-0000.31123.00 - Plumbing Plan Review Fee Fee Amount:$322.50 Account #: 111-0000.31127.00 - Recreation Fee Fee Amount:$575.80 Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Plumbing Scope)Fee Amount:$5.00 Total Paid:$98,377.64 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. CEDAR SIDING AND TRIM STAIN COLOR UTILITY APPROVAL & VERIFICATION This frm serves to verif that the proposed improvements will not impact any existing or proposed utility services, and also to verif service availability and location fr new construction and should be used in conjunction with preparing your utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted to the fllowing utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COM­ MENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact The Town of Vail. Subject Property Address: __ ____ __ ___ __ Lot _ _ Block Subdivision: ______ _ Primary Contact/ Owner Representative: ___ ___ ____ _____ _ Phone: _______ _ Plans Dated: _______ _ Primary Contact/Owner Representative Signature Authorized Signature CENTURY LINK 970.328.8288 (tel) 970.328.8282 (fax) Contacts: Kelly McClernon kelly.mcclernon@centurylink.com XCEL HIGH PRESSURE GAS 970.244.2788 (tel) 970.390.4777 (cell) 970.244.2661 (fax) Contact: Ron Smith ron.smith@xcelenerov.com HOLY CROSS ENERGY 970.947.5425 (tel) 970.945.4081 (fax) Contact: Jeff Vroom jvroom@holycross.com XCEL Energy 970.262.4032 (tel) 970.262.4038 (fax) Contacts: Britt Mace brittany.mace@xcelenergy.com EAGLE RIVER WATER & SANITATION DISTRICT 970.477.5449 (tel) 970.845. 7218 (fax) Contact: Tug Birk dbirk@erwsd.org COMCAST CABLE 970.930.4713 (tel) 303.603.1004 (fax) Contact: Michael Johnson Michaeljohnson@cable.comcast.com COOT (Only in COOT Right-of-way) 970.683.6284 (tel) Contact: Dan Roussin Daniel.roussin@dot.state.co.us 1. Utilit locations must be obtained befre digging. NOTES: Comments Date 2. A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way. Contact the Public Work Department fr verification 970.479.2198. 3. It is the responsibilit of the utilit company and the applicant to resolve problems identified above. 4. The Primary ContactOwner Representative is required to submit any revised drawings to the above agencies for re-approval & re-verification if the submited plans are altered in any way aſter the authorized signature date. 1450 Buffehr Creek Road 2 Cliffside Micheal Suman / Suman Architects 970.471.6122 07.13.2017 It is the responsibility of the customer to obtain locates and call to have moved any CenturyLink facilities in conflict with this project. 07/13/2017Kelly A McClernon 5/10/2016 Item Specs: 6601143632 http://www.mcnichols.com/jsp/template/item/includes/itemDetailPrint.jsp 1/2 Item Number : 6601143632 Product Line : Grating Product Type : Bar Weight : 15.04 #/SF Class : Close Mesh Trade Name : McNICHOLS Category : 11­W­4 Series Major Material : Plain Steel Minor Material : Hot Rolled AKA Description : 11­W­4 Construction : Welded Spacing Description : 11­W­4 Bearing Bar Height : 1.25 Bearing Bar Thickness : 0.1875 Bearing Bar Spacing : 0.6875 Surface : Smooth Cross Bar Spacing : 4.0 Percent Open Area : 69 Width : 36.0000 Length (Span for Grating) : 240.0000 SKU Type : Panel Cross Bar Type : Regular HS Item Number : 6601143632 Item Specifications: Accessories: Angle Banding Clips, Anchors, Etc End Plates Hardware Kick Plate Nosing Options: Add Studs The process of adding additional studs, different studs or different spacing to Embed angle McNICHOLS® Quality Bar Grating, Plain Steel, Close Mesh, 11­W­4 Series, 11­W­4, 36.0000" x 240.0000" PrintVisit us online at http://www.mcnichols.com Order Now: 1­877­884­4653 or email sales@mcnichols.com 1450 Buffehr Creek Road Chimney surround UTILITY APPROVAL & VERIFICATION This frm serves to verif that the proposed improvements will not impact any existing or proposed utility services, and also to verif service availability and location fr new construction and should be used in conjunction with preparing your utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted to the fllowing utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COM­ MENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact The Town of Vail. Subject Property Address: __ ____ __ ___ __ Lot _ _ Block Subdivision: ______ _ Primary Contact/ Owner Representative: ___ ___ ____ _____ _ Phone: _______ _ Plans Dated: _______ _ Primary Contact/Owner Representative Signature Authorized Signature CENTURY LINK 970.328.8288 (tel) 970.328.8282 (fax) Contacts: Kelly McClernon kelly.mcclernon@centurylink.com XCEL HIGH PRESSURE GAS 970.244.2788 (tel) 970.390.4777 (cell) 970.244.2661 (fax) Contact: Ron Smith ron.smith@xcelenerov.com HOLY CROSS ENERGY 970.947.5425 (tel) 970.945.4081 (fax) Contact: Jeff Vroom jvroom@holycross.com XCEL Energy 970.262.4032 (tel) 970.262.4038 (fax) Contacts: Britt Mace brittany.mace@xcelenergy.com EAGLE RIVER WATER & SANITATION DISTRICT 970.477.5449 (tel) 970.845. 7218 (fax) Contact: Tug Birk dbirk@erwsd.org COMCAST CABLE 970.930.4713 (tel) 303.603.1004 (fax) Contact: Michael Johnson Michaeljohnson@cable.comcast.com COOT (Only in COOT Right-of-way) 970.683.6284 (tel) Contact: Dan Roussin Daniel.roussin@dot.state.co.us 1. Utilit locations must be obtained befre digging. NOTES: Comments Date 2. A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way. Contact the Public Work Department fr verification 970.479.2198. 3. It is the responsibilit of the utilit company and the applicant to resolve problems identified above. 4. The Primary ContactOwner Representative is required to submit any revised drawings to the above agencies for re-approval & re-verification if the submited plans are altered in any way aſter the authorized signature date. 1450 Buffehr Creek Road 2 Cliffside Micheal Suman / Suman Architects 970.471.6122 07.13.2017 Michael Johnson 7-20-17Approved by Comcast UTILITY APPROVAL & VERIFICATION This frm serves to verif that the proposed improvements will not impact any existing or proposed utility services, and also to verif service availability and location fr new construction and should be used in conjunction with preparing your utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted to the fllowing utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COM­ MENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact The Town of Vail. Subject Property Address: ___________ __ Lot _ _ Block Subdivision: ______ _ Primary Contact/ Owner Representative: ___ ___ ____ _____ _ Phone: _______ _ Plans Dated: _______ _ Primary Contact/Owner Representative Signature Authorized Signature CENTURY LINK 970.328.8288 (tel) 970.328.8282 (fax) Contacts: Kelly McClernon kelly.mcclernon@centurylink.com XCEL HIGH PRESSURE GAS 970.244.2788 (tel) 970.390.4777 (cell) 970.244.2661 (fax) Contact: Ron Smith ron.smith@xcelenerov.com HOLY CROSS ENERGY 970.947.5425 (tel) 970.945.4081 (fax) Contact: Jeff Vroom jvroom@holycross.com XCEL Energy 970.262.4032 (tel) 970.262.4038 (fax) Contacts: Britt Mace brittany.mace@xcelenergy.com EAGLE RIVER WATER & SANITATION DISTRICT 970.477.5449 (tel) 970.845. 7218 (fax) Contact: Tug Birk dbirk@erwsd.org COMCAST CABLE 970.930.4713 (tel) 303.603.1004 (fax) Contact: Michael Johnson Michaeljohnson@cable.comcast.com COOT (Only in COOT Right-of-way) 970.683.6284 (tel) Contact: Dan Roussin Daniel.roussin@dot.state.co.us 1. Utilit locations must be obtained befre digging. NOTES: Comments Date 2. A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way. Contact the Public Work Department fr verification 970.479.2198. 3. It is the responsibilit of the utilit company and the applicant to resolve problems identified above. 4. The Primary ContactOwner Representative is required to submit any revised drawings to the above agencies for re-approval & re-verification if the submited plans are altered in any way aſter the authorized signature date. 7/14/17 1450 Buffehr Creek Road 2 Cliffside Micheal Suman / Suman Architects 970.471.6122 07.13.2017 PAINTED METAL FLASHING, PANELS AND STANDING SEAM ROOF COLOR NATURAL SANDSTONE VENEER WITH DRYSTACK JOINTS STUCCO COLOR BY SHERWIN WILLIAMS STUCCO FINISH 1450 Buffehr Creek Road Exterior Light Fixture-Type A Fixture Type: Catalog Number: Project: Location: WAC Lighting www.waclighting.com Phone (800) 526.2588 • Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050 Western Distribution Center 1750 Archibald Avenue • Ontario, CA 91760 Phone (800) 526.2588 • Fax (800) 526.2585 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAn 2014 Model: WL-LED100 LEDme® Step Light FEATURES • 316 marine grade cast stainless steel (SS) available • Direct wiring, no driver needed • Low profile, flush to wall aesthetics with no visible hardware • Turtle friendly (AM, RD colors) • 40,000 hour rated life • Balanced lighting, free of shadows with minimum glare • Up to 200 fixtures can be connected in parallel • Replaceable LED module • 5 year WAC Lighting product warranty ORDER NUMBER Model # Color Finish WL-LED100 WL-LED100F 120V 277V C AM RD BL White Amber Red Blue 3000K 610nm 640nm 450nm SS BK WT BN BZ Stainless Steel Black White Brushed nickel Bronze – – Example: WL-LED100F-BL-SS FIXTURE PERFORMANCE Model # Lm Model # Lm Model # Lm Model # Lm Model # Lm WL-LED100-C-SS 45 WL-LED100-C-BK 31 WL-LED100-C-WT 68 WL-LED100-C-BN 31 WL-LED100-C-BZ 32 WL-LED100-AM-SS 28 WL-LED100-AM-BK 19 WL-LED100-AM-WT 38 WL-LED100-AM-BN 19 WL-LED100-AM-BZ 21 WL-LED100-RD-SS 3 WL-LED100-RD-BK 2 WL-LED100-RD-WT 4 WL-LED100-RD-BN 2 WL-LED100-RD-BZ 2 WL-LED100-BL-SS 5 WL-LED100-BL-BK 3 WL-LED100-BL-WT 8 WL-LED100-BL-BN 3 WL-LED100-BL-BZ 4 WL-LED100F-C-SS 37 WL-LED100F-C-BK 25 WL-LED100F-C-WT 58 WL-LED100F-C-BN 25 WL-LED100F-C-BZ 27 WL-LED100F-AM-SS 20 WL-LED100F-AM-BK 14 WL-LED100F-AM-WT 29 WL-LED100F-AM-BN 14 WL-LED100F-AM-BZ 15 WL-LED100F-RD-SS 2 WL-LED100F-RD-BK 1.5 WL-LED100F-RD-WT 3 WL-LED100F-RD-BN 1.5 WL-LED100F-RD-BZ 2 WL-LED100F-BL-SS 4 WL-LED100F-BL-BK 3 WL-LED100F-BL-WT 6 WL-LED100F-BL-BN 3 WL-LED100F-BL-BZ 3 PRODUCT DESCRIPTION Horizontal rectangle LEDme® Step Light. Designed for safety and style on stairways, patios, decks, balcony areas, walkways and building perimeters. Features an architectural design. Energy efficient for long-lasting indoor and outdoor lighting solutions. Creates an attractive, romantic impression at night. 5" 3" 2a" 18" front 12" 18" x" 2" side 1d" 22" back SPECIFICATIONS Construction: Die-cast aluminum or 316 marine grade cast stainless steel Power: Direct wiring, no remote driver needed. Input voltage: 120V or 277V AC 50/60Hz Light Source: 3000K CCT Samsung HV-AC High Power LED, CRI: 85 Optional color lenses. Total power consumption of 3.9W Mounting: Fits into 2” × 4” J-Box with minimum inside dimensions of 3"L × 2"W × 2"H Includes bracket for J-Box mount. See next page for spacing recommendations Dimming: Dim to 10% with electronic low voltage (ELV) dimmer Approved dimmers: Lutron Skylark SELV-300P-WH and Leviton Vizia VPE04 Standards: IP66, UL listed for wet locations FINISHES SS BK WT BN BZ 1450 Buffehr Creek Road Exterior Light Fixture-Type B WAC Lighting www.waclighting.com Phone (800) 526.2588 • Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive • Port Washington, NY 11050 Phone (516) 515.5000 • Fax (516) 515.5050 Western Distribution Center 1750 Archibald Avenue • Ontario, CA 91760 Phone (800) 526.2588 • Fax (800) 526.2585 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAn 2014 Model: WL-LED100 LEDme® Step Light Spacing Recommendations for Optimal Light Distribution Stairs - Step Mount Mount in center of stair as close to the upper tread as possible. For best results use one light per step for steps narrower than 5'. Stairs - Wall Mount 8" 11" 12" 22" 8" Corridors / Hallways 12" - 18" 36" 36" H HEVI LITE, INC. 9714 Variel Ave, Chatsworth, CA 91311 Tel., (818) 341-8091 - Fax (818) 998-1986 Web Site http://www.hevilite.com HL-368 NOTE: e APPROVED: PROJECT: CATALOG NUMBER: TYPE: MADE IN THE USA Fixture Finish Lamping Voltage Options/Access. Wet/damp/dry location. SPECIFICATIONS DESCRIPTION: Compact MR16 adjustable accent fixture with integral straight glare shield. Suitable for wet/damp/dry location installations. MATERIAL: Standard overall material is 6061 aluminum. HL-368 - Machined Aluminum (Standard) HL-368-1 - Machined Stainless Steel HL-368-2b - Machined Brass FINISH: AA - Anodized Satin Aluminum AP - Powder Coat Aluminum BK - Powder Coat Black BZ - Powder Coat Bronze WT - Powder Coat White N - Natural, for Stainless Steel and Brass LAMPING: Halogen Lamps Lamp Type - 12V halogen MR16 lamp, bi-pin GX5.3 base, 50W max, not included. LED Lamps Lamp Type - High output LED, warm white (3000K CCT) standard, others available. 3LED - 3x1W LED, ave light output 260 lm 8LED - 3x2.7W LED, ave light output 457 lm Optics SP - Spot, 12º NF - Narrow Flood, 24º FL - Flood, 36º VOLTAGE: 12 - 12 VAC output transformer required, not included. MOUNTING: Fixture is designed with a 1/2" NPS adjustable mounting stem. OPTIONS: Lenses/Louvers/Color Filters LA-1 - Hexcell Louver (Black) LA-2 - Prismatic lens LA-3 - Linear spread lens LA-4 - Soft focus lens (diffused) LA-5 - Moonlight lens LA-6 - Blue lens See fixture accessories for more information. SAMPLE ORDER SPECIFICATION: HL-368-2b-N-12-LA-2 RATING: ORDER SPECIFICATION: _______________ - ________________ - _______________ - _______________ - _______________ THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF HEVI LITE, INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF HEVI LITE, INC. IS PROHIBITED. 57 2 1/4" 79 3 1/8" 4 9/16" 116 1 3/8" 35 1450 Buffehr Creek Road Exterior Light Fixture - Type C WINDOW AND DOOR CLADDING, WINDOW DIVIDE AND PAINTED STEEL STRUCTURE COLOR UTILITY APPROVAL & VERIFICATION This frm serves to verif that the proposed improvements will not impact any existing or proposed utility services, and also to verif service availability and location fr new construction and should be used in conjunction with preparing your utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted to the fllowing utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COM­ MENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact The Town of Vail. Subject Property Address: ___ ___ ______ _ Lot _ _ Block Subdivision: ______ _ Primary Contact/ Owner Representative: ___ ___ ____ _____ _ Phone: _______ _ Plans Dated: _______ _ Primary Contact/Owner Representative Signature Authorized Signature CENTURY LINK 970.328.8288 (tel) 970.328.8282 (fax) Contacts: Kelly McClernon kelly.mcclernon@centurylink.com XCEL HIGH PRESSURE GAS 970.244.2788 (tel) 970.390.4777 (cell) 970.244.2661 (fax) Contact: Ron Smith ron.smith@xcelenerov.com HOLY CROSS ENERGY 970.947.5425 (tel) 970.945.4081 (fax) Contact: Jeff Vroom jvroom@holycross.com XCEL Energy 970.262.4032 (tel) 970.262.4038 (fax) Contacts: Britt Mace brittany.mace@xcelenergy.com EAGLE RIVER WATER & SANITATION DISTRICT 970.477.5449 (tel) 970.845. 7218 (fax) Contact: Tug Birk dbirk@erwsd.org COMCAST CABLE 970.930.4713 (tel) 303.603.1004 (fax) Contact: Michael Johnson Michaeljohnson@cable.comcast.com COOT (Only in COOT Right-of-way) 970.683.6284 (tel) Contact: Dan Roussin Daniel.roussin@dot.state.co.us 1. Utilit locations must be obtained befre digging. NOTES: Comments Date 2. A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way. Contact the Public Work Department fr verification 970.479.2198. 3. It is the responsibilit of the utilit company and the applicant to resolve problems identified above. 4. The Primary ContactOwner Representative is required to submit any revised drawings to the above agencies for re-approval & re-verification if the submited plans are altered in any way aſter the authorized signature date. 1450 Buffehr Creek Road 2 Cliffside Micheal Suman / Suman Architects 970.471.6122 07.13.2017 Ron Smith HP Gas Clear 7-13-17 UTILITY APPROVAL & VERIFICATION This frm serves to verif that the proposed improvements will not impact any existing or proposed utility services, and also to verif service availability and location fr new construction and should be used in conjunction with preparing your utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted to the fllowing utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COM­ MENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact The Town of Vail. Subject Property Address: ___________ __ Lot _ _ Block Subdivision: ______ _ Primary Contact/ Owner Representative: ___ ___ ____ _____ _ Phone: _______ _ Plans Dated: _______ _ Primary Contact/Owner Representative Signature Authorized Signature CENTURY LINK 970.328.8288 (tel) 970.328.8282 (fax) Contacts: Kelly McClernon kelly.mcclernon@centurylink.com XCEL HIGH PRESSURE GAS 970.244.2788 (tel) 970.390.4777 (cell) 970.244.2661 (fax) Contact: Ron Smith ron.smith@xcelenerov.com HOLY CROSS ENERGY 970.947.5425 (tel) 970.945.4081 (fax) Contact: Jeff Vroom jvroom@holycross.com XCEL Energy 970.262.4032 (tel) 970.262.4038 (fax) Contacts: Britt Mace brittany.mace@xcelenergy.com EAGLE RIVER WATER & SANITATION DISTRICT 970.477.5449 (tel) 970.845. 7218 (fax) Contact: Tug Birk dbirk@erwsd.org COMCAST CABLE 970.930.4713 (tel) 303.603.1004 (fax) Contact: Michael Johnson Michaeljohnson@cable.comcast.com COOT (Only in COOT Right-of-way) 970.683.6284 (tel) Contact: Dan Roussin Daniel.roussin@dot.state.co.us 1. Utilit locations must be obtained befre digging. NOTES: Comments Date 2. A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way. Contact the Public Work Department fr verification 970.479.2198. 3. It is the responsibilit of the utilit company and the applicant to resolve problems identified above. 4. The Primary ContactOwner Representative is required to submit any revised drawings to the above agencies for re-approval & re-verification if the submited plans are altered in any way aſter the authorized signature date. 1450 Buffehr Creek Road 2 Cliffside Micheal Suman / Suman Architects 970.471.6122 07.13.2017 7/20/17 If gas meter relocation is needed please apply for service at xcelenergy.com 1 of 3 4/13/18 Service Calculation Clifftop Residence Lighting Demand Load line neutral Square Footage 5758 17274 17274 Small Appliance 2 1500 3000 3000 Laundry Circuit 2 1500 3000 3000 Total Load 23274 23274 First 3000w @ 100% 3000 3000 Next 3001 to 120000 @ 35% 7096 7095.9 Remainder @ 25% 0 0 Total Lighting Demand =======> 10096 10095.9 A/C and Heat Demand Air Conditioning Load 240V Qua KVA Total 3hp 2.5 ton 2 4.5 9 0 Air Conditioning Total 9 Electric Heat Load 240V 0 0 0 0 0 0 Electric Heat Total 0 Air Conditioning Larger Total Heat vs. Air Conditioning=> 9000 omit electric heat 2 of 3 4/13/18 Appliance Fastened in Place Voltage Qua Watts Line Neutral Dishwasher 120 2 1600 3200 3200 Disposal 120 2 1200 2400 2400 Refrigerator 120 1 1500 1500 1500 Under Cabinet Refrig 120 1 1000 1000 1000 Whirlpool Tub 120 2 1900 3800 3800 Hot Tub 240 1 5000 5000 0 Boiler Pump 120 6 200 1200 1200 Insta Hot 120 1 600 600 600 Microwave 120 1 800 800 800 compactor 120 1 1200 1200 1200 Fan blower 240 1 100 100 0 audio visual equipment 120 1 700 700 700 washer 120 1 1500 1500 1500 gas dryer 120 1 1500 1500 1500 Boiler 120 2 500 1000 1000 Steam Unit 240 1 8000 8000 0 Exhaust Fans 120 8 200 1600 1600 fan coil unit 240 3 800 2400 0 humidifier 240 1 1800 1800 0 fan coil unit 240 1 500 500 0 Heat Tape 240 8 2000 16000 0 0 0 0 0 0 0 Total Appliance (75% for 4 or more) 55800 22000 41850 16500 3 of 3 4/13/18 Elec.Clothes Dryer (5Kw min) 2 5000 Demand Factor % (220-18) 100% 10000 7000 Electric Cooking Equipment Demand Factor Kw (220-19) 6.4 6400 4480 Largest Motor * 25% volts , watts 240 4500 1125 0 Total Demand line 78471 Total Demand Neutral 38076 Line Amperage Demand 327 Neutral Amperage 159 220-22 First 200 at 100% 159 Remainder at 70% 0 Neutral Amperage Demand 159 System Voltage H,L 240 120 Service Size ====>> 350 Conductor Type AL or CU AL Wire Size per 310-16 note 3 500 AL XHHW Service lateral length in feet 400 Resistance per ft. in ohms==> 21.2 Percentage of voltage drop 3 Wire Size per voltage drop 3@ 250 AL XHHW Wire size 3@ 250 AL XHHW LOWER DOOR SCHEDULE - CLIFFTOP RESIDENCE 04.02.18 DOOR ROOM TYPE SIZE HINGE TEMP MATERIAL GLASS NOTES NO. NAME WxH (VIEW FROM OUT) U-VALUE 103 ELEVATOR HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR 104 HALL HINGED 3 0 x 8 0 R WOOD WOOD INTERIOR DOOR (OPTIONAL) 105 CLOSET 2 HINGED (2) 3 0x 8 0 R/L WOOD PAIR WOOD INTERIOR DOORS 106 BEDROOM 2 HINGED 3 0 x 8 0 R WOOD WOOD INTERIOR DOOR 107 BATH 2 HINGED 2 6 x 8 0 L WOOD WOOD INTERIOR DOOR 108 EXERCISE BARN DOOR (2) 2 6x 8 0 BARN WOOD WOOD INTERIOR DOORS, BARN DOOR HARDWARE 112 GAME ROOM SLIDING 6 5 1/2 x 8 0 RE:ELEV. T WOOD/GLASS 0.35 MULTI-SLIDE CUSTOM WOOD CLAD/GLASS EX. DOOR 113 BEDROOM SUITE 3 HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR 114 SUITE 3 CLOSET HINGED (2) 2 0x 8 0 R/L WOOD PAIR WOOD INTERIOR DOORS 115 BATH 3 HINGED 2 8 x 8 0 L WOOD WOOD INTERIOR DOOR 116 POWDER ROOM 3 HINGED 2 6 x 8 0 R WOOD WOOD INTERIOR DOOR 117 STORAGE ROOM 3 HINGED 2 8 x 8 0 L WOOD WOOD INTERIOR DOOR 118a MECH ROOM HINGED 3 0 x 8 0 L WOOD 20 MIN WOOD SOILD CORE-ACOUSTICAL SEALS 118b MECH ROOM HINGED 3 0 x 8 0 L WOOD 20 MIN WOOD SOILD CORE-WEATHER STRIPPING MAIN DOOR SCHEDULE - CLIFFTOP RESIDENCE 04.02.18 DOOR ROOM TYPE SIZE HINGE TEMP MATERIAL GLASS NOTES NO. NAME WxH (VIEW FROM OUT) U-VALUE 202 WINE ROOM HINGED 3 0 x 8 0 L T GLASS INTERIOR GLASS DOOR, WEATHER STRIPPING 203 ELEV. HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR 204 HALL HINGED 3 0 x 8 0 R WOOD WOOD INTERIOR DOOR 205 CLOSET 1 HINGED 2 6 x 8 0 R WOOD WOOD INTERIOR DOOR 206 BEDROOM SUITE 1 HINGED 3 0 x 8 0 R WOOD WOOD INTERIOR DOOR (OPTIONAL) 207 BATH 1 HINGED 2 6 x 8 0 L WOOD WOOD INTERIOR DOOR 208 STUDY BARN (2) 2 6x 8 0 BARN WOOD WOOD INTERIOR DOORS, BARN DOOR HARDWARE 210 GUEST BATHROOM HINGED 2 6 x 8 0 L WOOD WOOD INTERIOR DOOR 211 GUEST TOILET HINGED 2 4 x 8 0 L WOOD WOOD INTERIOR DOOR 212 UTILITY CLOSET HINGED 2 6 x 8 0 L WOOD WOOD INTERIOR DOOR 214 GUEST BEDROOM HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR 215 GUEST CLOSET HINGED 2 8 x 8 0 L WOOD WOOD INTERIOR DOOR 216 POWDER ROOM 2 HINGED 2 6 x 8 0 R WOOD WOOD INTERIOR DOOR 217 LAUNDRY HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR 218 LAUNDRY STORAGE HINGED 2 6 x 8 0 R WOOD WOOD INTERIOR DOOR 219 STORAGE ROOM 2 HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR UPPER DOOR SCHEDULE - CLIFFTOP RESIDENCE 04.02.18 DOOR TYPE SIZE HINGE TEMP MATERIAL GLASS NOTES NO. NAME WxH (VIEW FROM OUT) U-VALUE 302 ENTRY HINGED 3 8 x 8 1 1/2 L T WOOD/GLASS 0.35 CUSTOM WOOD/GLASS EXTERIOR DOOR 303 ELEV. HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR 304 DINING ROOM SLIDING 12 9 x 10 6 RE:ELEV. T WOOD/GLASS 0.35 MULTI-SLIDE CUSTOM WOOD CLAD/GLASS EX. DOOR 306 KITCHEN HINGED 3 0 x 8 4 R T WOOD/GLASS 0.35 WOOD CLAD/GLASS EXTERIOR DOOR 309 LIVING ROOM SLIDING 16 0 x 10 6 RE:ELEV. T WOOD/GLASS 0.35 LIFT/SLIDE CUSTOM WOOD CLAD/GLASS EX. DOOR 310 MASTER BATHROOM HINGED 2 6 x 8 0 L WOOD WOOD INTERIOR DOOR 311 MASTER TOILET HINGED 2 4 x 8 0 L WOOD WOOD INTERIOR DOOR 312 COAT CLOSET HINGED 2 6 x 8 0 L WOOD WOOD INTERIOR DOOR 314 MASTER BEDROOM SLIDING 10 0 x 8 0 RE:ELEV. T WOOD/GLASS 0.35 MULTI-SLIDE CUSTOM WOOD CLAD/GLASS EX. DOOR 315 MASTER CLOSET HINGED 2 8 x 8 0 L WOOD WOOD INTERIOR DOOR 316 POWER ROOM 1 HINGED 2 6 x 8 0 R WOOD WOOD INTERIOR DOOR 317a MUD ROOM HINGED 3 0 x 8 0 R WOOD 20 MIN WOOD SOILD CORE-WEATHER STRIPPING 317b MUD ROOM HINGED 3 0 x 8 0 R T WOOD/GLASS 0.35 WOOD CLAD/GLASS EXTERIOR DOOR 317c MUD ROOM HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR 318 MUD CLOSET HINGED 3 0 x 8 0 R WOOD WOOD INTERIOR DOOR 319 GARAGE GARAGE DR 18 0 x 9 0 GARAGE DR T WOOD/GLASS 0.35 GARAGE DOOR 321 ELECTRICAL CLOSET HINGED 3 0 x 6 0 L WOOD CUSTOM WOOD DOOR WITH METER CUTOUT REScheck Software Version 4.6.4 Compliance Certificate Project Clifftop Residence Energy Code: 2015 IECC Location: Vail, Colorado Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 5,486 ft2 Glazing Area 30% Climate Zone: 6 (9248 HDD) Permit Date: Construction Site: 1450 Buffehr Creek Road Vail, CO 81657 Owner/Agent: Michael Suman Suman Architects michael@sumanarchitects.com Designer/Contractor: Permit Number: Compliance: Passes using UA trade-off 8.5% Better Than Code Maximum UA: 915 Your UA: 837 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Above Grade Walls: Wood Frame, 16" o.c. 4,850 24.0 12.5 0.030 97 Windows: Wood Frame:Double Pane with Low-E 889 0.300 267 Garage Door: Solid 162 0.300 49 Glass Door: Glass 582 0.350 204 Slab: Slab-On-Grade:Unheated Insulation depth: 6.0' 176 10.0 0.684 120 Flat Roof: Flat Ceiling or Scissor Truss 434 48.0 34.4 0.014 6 Pitched Roof: Flat Ceiling or Scissor Truss 1,268 48.0 34.4 0.014 18 Gaden Roof: Flat Ceiling or Scissor Truss 581 52.0 15.0 0.018 10 Basement Wall 1: Solid Concrete or Masonry Wall height: 9.5' Depth below grade: 9.5' Insulation depth: 9.5' 1,384 6.2 6.2 0.048 66 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: Clifftop Residence Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck Page 1 of10 04/02/18Report date: Project Title: Clifftop Residence Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck Page 2 of10 04/02/18Report date: Inspection Checklist Requirements: 0.0% were addressed directly in the REScheck software REScheck Software Version 4.6.4 Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Pre-Inspection/Plan Review Plans Verified Value Field Verified Value Complies? Comments/Assumptions 103.1, 103.2 [PR1]1 Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. Complies Does Not Not Observable Not Applicable 103.1, 103.2, 403.7 [PR3]1 Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. Complies Does Not Not Observable Not Applicable 302.1, 403.7 [PR2]2 Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_____ Cooling: Btu/hr_____ Heating: Btu/hr_____ Cooling: Btu/hr_____ Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Clifftop Residence Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck Page 3 of10 04/02/18Report date: Section # & Req.ID Foundation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 402.1.2 [FO1]1 Slab edge insulation R-value. R-_____ Unheated Heated R-_____ Unheated Heated Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.2 [FO3]1 Slab edge insulation depth/length. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1 [FO4]1 Conditioned basement wall insulation R-value. Where interior insulation is used, verification may need to occur during Insulation Inspection. Not required in warm-humid locations in Climate Zone 3. R-_____ R-_____ R-_____ R-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [FO5]1 Conditioned basement wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable 402.2.9 [FO6]1 Conditioned basement wall insulation depth of burial or distance from top of wall. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2.1 [FO11]2 A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. Complies Does Not Not Observable Not Applicable 403.9 [FO12]2 Snow- and ice-melting system controls installed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Clifftop Residence Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck Page 4 of10 04/02/18Report date: Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 402.1.1, 402.3.4 [FR1]1 Door U-factor. U-_____ U-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1, 402.3.1, 402.3.3, 402.3.6, 402.5 [FR2]1 Glazing U-factor (area-weighted average). U-_____ U-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.3 [FR4]1 U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. Complies Does Not Not Observable Not Applicable 402.4.1.1 [FR23]1 Air barrier and thermal barrier installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable 402.4.3 [FR20]1 Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. Complies Does Not Not Observable Not Applicable 402.4.5 [FR16]2 IC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate ≤2.0 cfm leakage at 75 Pa. Complies Does Not Not Observable Not Applicable 403.2.1 [FR12]1 Supply and return ducts in attics insulated >= R-8 where duct is >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. Complies Does Not Not Observable Not Applicable 403.3.3.5 [FR15]3 Building cavities are not used as ducts or plenums. Complies Does Not Not Observable Not Applicable 403.4 [FR17]2 HVAC piping conveying fluids above 105 ºF or chilled fluids below 55 ºF are insulated to ≥R- 3. R-_____ R-_____ Complies Does Not Not Observable Not Applicable 403.4.1 [FR24]1 Protection of insulation on HVAC piping. Complies Does Not Not Observable Not Applicable 403.5.3 [FR18]2 Hot water pipes are insulated to ≥R-3. R-_____ R-_____ Complies Does Not Not Observable Not Applicable 403.6 [FR19]2 Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Clifftop Residence Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck Page 5 of10 04/02/18Report date: Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Clifftop Residence Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck Page 6 of10 04/02/18Report date: Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 303.1 [IN13]2 All installed insulation is labeled or the installed R-values provided. Complies Does Not Not Observable Not Applicable 402.1.1, 402.2.5, 402.2.6 [IN3]1 Wall insulation R-value. If this is a mass wall with at least ½ of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). R-_____ Wood Mass Steel R-_____ Wood Mass Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [IN4]1 Wall insulation is installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Clifftop Residence Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck Page 7 of10 04/02/18Report date: Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions 402.1.1, 402.2.1, 402.2.2, 402.2.6 [FI1]1 Ceiling insulation R-value. R-_____ Wood Steel R-_____ Wood Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.1.1, 303.2 [FI2]1 Ceiling insulation installed per manufacturer’s instructions. Blown insulation marked every 300 ft². Complies Does Not Not Observable Not Applicable 402.2.3 [FI22]2 Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. Complies Does Not Not Observable Not Applicable 402.2.4 [FI3]1 Attic access hatch and door insulation ≥R-value of the adjacent assembly. R-_____ R-_____ Complies Does Not Not Observable Not Applicable 402.4.1.2 [FI17]1 Blower door test @ 50 Pa. <=5 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. ACH 50 =_____ ACH 50 =_____ Complies Does Not Not Observable Not Applicable 403.2.3 [FI4]1 Duct tightness test result of <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing Inspection. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable 403.3.2 [FI27]1 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer’s air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer’s air handler enclosure. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable 403.3.2.1 [FI24]1 Air handler leakage designated by manufacturer at <=2% of design air flow. Complies Does Not Not Observable Not Applicable 403.1.1 [FI9]2 Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. Complies Does Not Not Observable Not Applicable 403.1.2 [FI10]2 Heat pump thermostat installed on heat pumps. Complies Does Not Not Observable Not Applicable 403.5.1 [FI11]2 Circulating service hot water systems have automatic or accessible manual controls. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Clifftop Residence Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck Page 8 of10 04/02/18Report date: Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions 403.6.1 [FI25]2 All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits. Complies Does Not Not Observable Not Applicable 403.2 [FI26]2 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. Complies Does Not Not Observable Not Applicable 403.5.1.1 [FI28]2 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. Complies Does Not Not Observable Not Applicable 403.5.1.2 [FI29]2 Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. Complies Does Not Not Observable Not Applicable 403.5.2 [FI30]2 Water distribution systems that have recirculation pumps that pump water from a heated water supply pipe back to the heated water source through a cold water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104ºF. Complies Does Not Not Observable Not Applicable 403.5.4 [FI31]2 Drain water heat recovery units tested in accordance with CSA B55.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. Complies Does Not Not Observable Not Applicable 404.1 [FI6]1 75% of lamps in permanent fixtures or 75% of permanent fixtures have high efficacy lamps. Does not apply to low-voltage lighting. Complies Does Not Not Observable Not Applicable 404.1.1 [FI23]3 Fuel gas lighting systems have no continuous pilot light. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Clifftop Residence Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck Page 9 of10 04/02/18Report date: Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions 401.3 [FI7]2 Compliance certificate posted. Complies Does Not Not Observable Not Applicable 303.3 [FI18]3 Manufacturer manuals for mechanical and water heating systems have been provided. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Clifftop Residence Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck Page 10 of10 04/02/18Report date: 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value 36.50Above-Grade Wall 12.50Below-Grade Wall 10.00Floor 82.38Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.30Window 0.35Door Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name: Date: Comments WINDOW SCHEDULE - CLIFFTOP RESIDENCE 04.02.18 WIN ROOM TYPE NOM. HINGE TEMP GLAZING U- NOTES NO. NAME W/H (VIEW FROM OUT) VALUE 1 BEDROOM SUITE 3 C/FIX (2) 3 4 x 4 8 / 3 4 x 4 8 L/R LOW-E DOUBLE 0.30 EGRESS 2 REC ROOM C/FIX (2) 2 6x 5 8/6 4x 5 8 L/R LOW-E DOUBLE 0.30 3 EXERCISE C/FIX 2 6x 5 0/5 0x 5 0 R LOW-E DOUBLE 0.30 EGRESS 4 BEDROOM 2 C/FIX 2 6x 5 0/5 0x 5 0 L LOW-E DOUBLE 0.30 EGRESS 5A GUEST BEDROOM C/FIX (2) 3 4x 6 0/ 3 4x 6 0 L/R LOW-E DOUBLE 0.30 EGRESS 5B GUEST BATHROOM C 3 0x 6 0 R T LOW-E DOUBLE 0.30 ELECTRIFIED GLASS 6 GUEST BATHROOM C 3 0x 6 0 L T LOW-E DOUBLE 0.30 WATERPROOF FINISH IN SHOWER, ELECTRIFIED GLASS 7 FAMILY ROOM C/FIX (2) 2 6x 6 10/6 4x 6 10 L/R LOW-E DOUBLE 0.30 8 STUDY C/FIX 2 6x 5 0/5 0x 5 0 R LOW-E DOUBLE 0.30 EGRESS 9 BEDROOM SUITE 1 C/FIX 2 6x 5 0/5 0x 5 0 L LOW-E DOUBLE 0.30 EGRESS 10 MASTER BATHROOM C 3 0x 6 0 R T LOW-E DOUBLE 0.30 ELECTRIFIED GLASS 11 MASTER BATHROOM C 3 0x 6 0 L T LOW-E DOUBLE 0.30 WATERPROOF FINISH IN SHOWER, ELECTRIFIED GLASS 12 KITCHEN AWN/FIX 3 11x 5 6/3 11x 2 0 AWN LOW-E DOUBLE 0.30 MULL TO WDW 13, MOTORIZED OPERATION 13 KITCHEN AWN/FIX 3 11x 5 6/3 11x 2 0 AWN LOW-E DOUBLE 0.30 MULL TO WDW 12,14, MOTORIZED OPERATION 14 KITCHEN AWN/FIX 3 11x 5 6/3 11x 2 0 AWN LOW-E DOUBLE 0.30 MULL TO WDW 13, MOTORIZED OPERATION 15 STAIR FIX (2) 7 6x 1 7 1/2 T LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER WINDOW SCHEDULE - CLIFFTOP RESIDENCE 04.02.18 WIN ROOM TYPE NOM. HINGE TEMP GLAZING U- NOTES NO. NAME W/H (VIEW FROM OUT) VALUE 16 GUEST BEDROOM AWN (2) 4 0x 2 6 AWN LOW-E DOUBLE 0.30 17 MASTER BEDROOM AWN (2) 4 0x 2 6 AWN LOW-E DOUBLE 0.30 18 POWER ROOM 1 C 2 0x 3 6 L LOW-E DOUBLE 0.30 19 STAIR FIX/AWN (2) 5 1 3/4x 1 7 1/2 AWN LOW-E DOUBLE 0.30 FIELD VER. HEIGHT WITH MANF. MULLION COVER, MOTORIZED OPERATION WINDOW SCHEDULE - CLIFFTOP RESIDENCE 04.02.18 WIN ROOM TYPE NOM. HINGE TEMP GLAZING U- NOTES NO. NAME W/H (VIEW FROM OUT) VALUE 20 DINING FIX 8 0x 5 6/8 0x 1 10 LOW-E DOUBLE 0.30 MULL TO WDW 21 21 DINING C/FIX 3 7 3/4x 5 6/3 7 3/4x 1 10 L LOW-E DOUBLE 0.30 MULL TO WDW 20 22 ENTRY FIX/AWN (3) 3 1 1/2x 2 8 1/2 AWN T LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER 23 ENTRY FIX 3 1 1/2x 1 7 1/2 T LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER 24 ENTRY FIX 4 0x 1 7 1/2 T LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER 25 STAIR FIX (6) 3 6 1/4x 1 7 1/2 LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER 26 STAIR FIX (2) 7 6x 1 7 1/2 LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER WINDOW SCHEDULE - CLIFFTOP RESIDENCE 04.02.18 WIN ROOM TYPE NOM. HINGE TEMP GLAZING U- NOTES NO. NAME W/H (VIEW FROM OUT) VALUE 27 BEDROOM SUITE 1 AWN 6 0x 2 6 AWN T LOW-E DOUBLE 0.30 28 KITCHEN FIX 2 6x 5 4/2 6x 2 0 T LOW-E DOUBLE 0.30 29 KITCHEN F IX 3 4x 2 0 T LOW-E DOUBLE 0.30 30 KITCHEN FIX 2 6x 5 4/2 6x 2 0 T LOW-E DOUBLE 0.30 31 KITCHEN FOLDING (3) 3 0x 5 6 FOLDING T LOW-E DOUBLE 0.30 CUSTOM WINDOW, COOR'D WITH COUNTERTOP 31a KITCHEN AWN/FIX (3) 3 0x 2 0 AWN T LOW-E DOUBLE 0.30 MOTORIZED OPERATION 32 ENTRY FIX (3) 1 3 1/2x 2 8 1/2 T LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER 33 ENTRY FIX 1 3 1/2x 1 7 1/2 T LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER 34 STAIR FIX (6) 5 1 3/4x 1 7 1/2 LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER 35 STAIR AWN/FIX (2) 5 1 3/4x 1 7 1/2 AWN LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER PERMIT FEE RECEIPT Case # B18-0142 Date Printed: 05/17/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: B18-0142 Status: Approved Permit Number: Date Started: 04/16/2018 Permit Type: Construction Subcases Single Family Lot Number: 2 Property: 1450 BUFFEHR CREEK RD (210312102007) (210312102007) Contacts Contact Type: Applicant Company Name: Vail Custom Builders Full Name: Benno Scheidegger Address: 0429 Edwards Access Road A207 Ed, CO 81657 Email: benno@vailcustom.com Contact Type: Property Owner Full Name: CLIFFTOP LLC Address: Permit Fees Fee Information Account Amount Construction Tax 110-0000.31060.00 $68,600.00 Will Call Fee 001-0000.31128.00 $15.00 Payment Information Date Paid Payment Type Amount Will Call Fee 05/17/2018 Credit Card $15.00 Paid By: - Notes: visa-benno scheidegger Construction Tax 05/17/2018 Credit Card $982.40 Paid By: - Notes: visa-benno scheidegger FEE TOTAL $68,615.00 AMOUNT PAID $997.40 BALANCE DUE $0.00 05/17/2018 - 12:59:21 PM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657 1 / 1 ACTION FORM Design Review Board (DRB) Department of Community Development 75 South Frontage Road West Vail, CO 81657 Tel: 970-479-2139 www.vailgov.com Project Name: Clifftop LLC Residence 2017 Application Number: DRB17-0323 Application Type: New Construction Date Applied: 07/24/2017 Project Description:The redevelopment of 1450 Buffehr Creek Road with a new single family residence. CONTACTS Contact Type: Applicant Full Name: Beck Building Company (Kevin O'Donnell) Address: P.O. Box 4030 Vail, CO 81658 Phone: 9709040087 Contact Type: Applicant Full Name: Suman Architects (Michael Suman) Address: 141 East Meadow Drive Suite 211 Vail, CO 81657 Phone: 9704716122 Contact Type: Property Owner Full Name: CLIFFTOP LLC (Jim Stovall) Address: Phone: None Contact Type: Property Owner Full Name: CLIFFTOP LLC (Don Brownstein) Address: Phone: None Project Address: 1450 BUFFEHR CREEK RD (210312102007) (210312102007) Job Site Location: Legal Description: Subdivision: CLIFFSIDE SUBDIVISION Lot: 2 Block:No Data Parcel Number: 210312102007 BOARDS/STAFF ACTION Motion By: Kjesbo Action: Approved Second By: Cahill Vote: 4-0-0 Date: 08/16/2017 Conditions: - Prior to submittal of a building permit application, the applicant shall revise the plans to show a minimum of ten (10) serviceberry shrubs, 5-gallon container size, and three (3) aspen trees, 2-inch caliper, on the south and southeast side of the proposed home. - Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. - Design Review Board approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12-3-3 Appeals. - No changes to these plans maybe made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Planner: Jonathan Spence