HomeMy WebLinkAboutB18-0142_Approved Documents_1526584147.pdf75 South Frontage Road
West,
Vail, CO 81657
Office: 970.479.2139
Inspection Line: 970.479.2149
Construction
B18-0142
Issued: 05/17/2018
TOWN OF VAIL
Property Information
Address: 1450 BUFFEHR CREEK RD (210312102007) ( 210312102007 )
Unit #:
Parcel Number: 210312102007
Legal Description: Subdivision: CLIFFSIDE Lot: 2
Contacts
Contact Type: Applicant
Full Name: Benno Scheidegger
Address: 0429 Edwards Access Road A207 Ed, CO 81657 Phone: 9709268771
Contact Type: Property Owner
Full Name: CLIFFTOP LLC
Address: Phone: None
Contractor
Contractor Type: General
Company: Vail Custom Builders
State License #: Phone: 970-904-0512
Project Information
Project Name: Clifftop LLC Residence 2017
Project Description: Complete Demo of an existing home and construct a new single family residence
Fees Paid
Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$14,514.75
Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$9,434.59
Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$68,600.00
Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$2,900.00
Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$725.00
Account #: 001-0000.31111.00 - Plumbing Permit Fee Fee Amount:$1,290.00
Account #: 001-0000.31123.00 - Plumbing Plan Review Fee Fee Amount:$322.50
Account #: 111-0000.31127.00 - Recreation Fee Fee Amount:$575.80
Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00
Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00
Account #: 001-0000.31128.00 - Will Call Fee (Plumbing Scope)Fee Amount:$5.00
Total Paid:$98,377.64
Conditions
CONDITIONS UNDER WHICH PERMITS BECOME VOID:
If construction is not begun within 6 months from the date permit was issued.
If more than 5 months elapses between inspections.
If incorrect information is given on the application at the time the permit was issued.
Christopher Jarecki - Town of Vail Building Official
NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal
law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees.
CEDAR SIDING AND TRIM STAIN COLOR
UTILITY APPROVAL & VERIFICATION
This frm serves to verif that the proposed improvements will not impact any existing or proposed utility services, and
also to verif service availability and location fr new construction and should be used in conjunction with preparing your
utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted
to the fllowing utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COM
MENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact
The Town of Vail.
Subject Property Address: __ ____ __ ___ __ Lot _ _ Block Subdivision: ______ _
Primary Contact/ Owner Representative: ___ ___ ____ _____ _ Phone: _______ _
Plans Dated: _______ _
Primary Contact/Owner Representative Signature
Authorized Signature
CENTURY LINK
970.328.8288 (tel)
970.328.8282 (fax)
Contacts: Kelly McClernon
kelly.mcclernon@centurylink.com
XCEL HIGH PRESSURE GAS
970.244.2788 (tel)
970.390.4777 (cell)
970.244.2661 (fax)
Contact: Ron Smith
ron.smith@xcelenerov.com
HOLY CROSS ENERGY
970.947.5425 (tel)
970.945.4081 (fax)
Contact: Jeff Vroom
jvroom@holycross.com
XCEL Energy
970.262.4032 (tel)
970.262.4038 (fax)
Contacts: Britt Mace
brittany.mace@xcelenergy.com
EAGLE RIVER WATER & SANITATION
DISTRICT
970.477.5449 (tel)
970.845. 7218 (fax)
Contact: Tug Birk
dbirk@erwsd.org
COMCAST CABLE
970.930.4713 (tel)
303.603.1004 (fax)
Contact: Michael Johnson
Michaeljohnson@cable.comcast.com
COOT (Only in COOT Right-of-way)
970.683.6284 (tel)
Contact: Dan Roussin
Daniel.roussin@dot.state.co.us
1. Utilit locations must be obtained befre digging.
NOTES:
Comments Date
2. A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way. Contact the
Public Work Department fr verification 970.479.2198.
3. It is the responsibilit of the utilit company and the applicant to resolve problems identified above.
4. The Primary ContactOwner Representative is required to submit any revised drawings to the above agencies for
re-approval & re-verification if the submited plans are altered in any way aſter the authorized signature date.
1450 Buffehr Creek Road 2 Cliffside
Micheal Suman / Suman Architects 970.471.6122
07.13.2017
It is the responsibility of the customer to obtain
locates and call to have moved any CenturyLink
facilities in conflict with this project.
07/13/2017Kelly A McClernon
5/10/2016 Item Specs: 6601143632
http://www.mcnichols.com/jsp/template/item/includes/itemDetailPrint.jsp 1/2
Item Number : 6601143632
Product Line : Grating
Product Type : Bar
Weight : 15.04 #/SF
Class : Close Mesh
Trade Name : McNICHOLS
Category : 11W4 Series
Major Material : Plain Steel
Minor Material : Hot Rolled
AKA Description : 11W4
Construction : Welded
Spacing Description : 11W4
Bearing Bar Height : 1.25
Bearing Bar Thickness : 0.1875
Bearing Bar Spacing : 0.6875
Surface : Smooth
Cross Bar Spacing : 4.0
Percent Open Area : 69
Width : 36.0000
Length (Span for Grating) : 240.0000
SKU Type : Panel
Cross Bar Type : Regular
HS Item Number : 6601143632
Item Specifications:
Accessories:
Angle Banding Clips, Anchors, Etc
End Plates Hardware Kick Plate
Nosing
Options:
Add Studs The process of adding additional studs, different studs or different spacing to
Embed angle
McNICHOLS® Quality Bar Grating, Plain Steel, Close Mesh, 11W4 Series, 11W4, 36.0000" x
240.0000"
PrintVisit us online at http://www.mcnichols.com
Order Now: 18778844653 or email sales@mcnichols.com
1450 Buffehr Creek Road
Chimney surround
UTILITY APPROVAL & VERIFICATION
This frm serves to verif that the proposed improvements will not impact any existing or proposed utility services, and
also to verif service availability and location fr new construction and should be used in conjunction with preparing your
utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted
to the fllowing utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COM
MENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact
The Town of Vail.
Subject Property Address: __ ____ __ ___ __ Lot _ _ Block Subdivision: ______ _
Primary Contact/ Owner Representative: ___ ___ ____ _____ _ Phone: _______ _
Plans Dated: _______ _
Primary Contact/Owner Representative Signature
Authorized Signature
CENTURY LINK
970.328.8288 (tel)
970.328.8282 (fax)
Contacts: Kelly McClernon
kelly.mcclernon@centurylink.com
XCEL HIGH PRESSURE GAS
970.244.2788 (tel)
970.390.4777 (cell)
970.244.2661 (fax)
Contact: Ron Smith
ron.smith@xcelenerov.com
HOLY CROSS ENERGY
970.947.5425 (tel)
970.945.4081 (fax)
Contact: Jeff Vroom
jvroom@holycross.com
XCEL Energy
970.262.4032 (tel)
970.262.4038 (fax)
Contacts: Britt Mace
brittany.mace@xcelenergy.com
EAGLE RIVER WATER & SANITATION
DISTRICT
970.477.5449 (tel)
970.845. 7218 (fax)
Contact: Tug Birk
dbirk@erwsd.org
COMCAST CABLE
970.930.4713 (tel)
303.603.1004 (fax)
Contact: Michael Johnson
Michaeljohnson@cable.comcast.com
COOT (Only in COOT Right-of-way)
970.683.6284 (tel)
Contact: Dan Roussin
Daniel.roussin@dot.state.co.us
1. Utilit locations must be obtained befre digging.
NOTES:
Comments Date
2. A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way. Contact the
Public Work Department fr verification 970.479.2198.
3. It is the responsibilit of the utilit company and the applicant to resolve problems identified above.
4. The Primary ContactOwner Representative is required to submit any revised drawings to the above agencies for
re-approval & re-verification if the submited plans are altered in any way aſter the authorized signature date.
1450 Buffehr Creek Road 2 Cliffside
Micheal Suman / Suman Architects 970.471.6122
07.13.2017
Michael Johnson 7-20-17Approved by Comcast
UTILITY APPROVAL & VERIFICATION
This frm serves to verif that the proposed improvements will not impact any existing or proposed utility services, and
also to verif service availability and location fr new construction and should be used in conjunction with preparing your
utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted
to the fllowing utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COM
MENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact
The Town of Vail.
Subject Property Address: ___________ __ Lot _ _ Block Subdivision: ______ _
Primary Contact/ Owner Representative: ___ ___ ____ _____ _ Phone: _______ _
Plans Dated: _______ _
Primary Contact/Owner Representative Signature
Authorized Signature
CENTURY LINK
970.328.8288 (tel)
970.328.8282 (fax)
Contacts: Kelly McClernon
kelly.mcclernon@centurylink.com
XCEL HIGH PRESSURE GAS
970.244.2788 (tel)
970.390.4777 (cell)
970.244.2661 (fax)
Contact: Ron Smith
ron.smith@xcelenerov.com
HOLY CROSS ENERGY
970.947.5425 (tel)
970.945.4081 (fax)
Contact: Jeff Vroom
jvroom@holycross.com
XCEL Energy
970.262.4032 (tel)
970.262.4038 (fax)
Contacts: Britt Mace
brittany.mace@xcelenergy.com
EAGLE RIVER WATER & SANITATION
DISTRICT
970.477.5449 (tel)
970.845. 7218 (fax)
Contact: Tug Birk
dbirk@erwsd.org
COMCAST CABLE
970.930.4713 (tel)
303.603.1004 (fax)
Contact: Michael Johnson
Michaeljohnson@cable.comcast.com
COOT (Only in COOT Right-of-way)
970.683.6284 (tel)
Contact: Dan Roussin
Daniel.roussin@dot.state.co.us
1. Utilit locations must be obtained befre digging.
NOTES:
Comments Date
2. A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way. Contact the
Public Work Department fr verification 970.479.2198.
3. It is the responsibilit of the utilit company and the applicant to resolve problems identified above.
4. The Primary ContactOwner Representative is required to submit any revised drawings to the above agencies for
re-approval & re-verification if the submited plans are altered in any way aſter the authorized signature date.
7/14/17
1450 Buffehr Creek Road 2 Cliffside
Micheal Suman / Suman Architects 970.471.6122
07.13.2017
PAINTED METAL FLASHING,
PANELS AND STANDING SEAM
ROOF COLOR
NATURAL SANDSTONE VENEER
WITH DRYSTACK JOINTS
STUCCO COLOR BY SHERWIN
WILLIAMS
STUCCO FINISH
1450 Buffehr Creek Road
Exterior Light Fixture-Type A
Fixture Type:
Catalog Number:
Project:
Location:
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Avenue • Ontario, CA 91760
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAn 2014
Model: WL-LED100
LEDme® Step Light
FEATURES
• 316 marine grade cast stainless steel (SS) available
• Direct wiring, no driver needed
• Low profile, flush to wall aesthetics with no visible hardware
• Turtle friendly (AM, RD colors)
• 40,000 hour rated life
• Balanced lighting, free of shadows with minimum glare
• Up to 200 fixtures can be connected in parallel
• Replaceable LED module
• 5 year WAC Lighting product warranty
ORDER NUMBER
Model # Color Finish
WL-LED100
WL-LED100F
120V
277V
C
AM
RD
BL
White
Amber
Red
Blue
3000K
610nm
640nm
450nm
SS
BK
WT
BN
BZ
Stainless Steel
Black
White
Brushed nickel
Bronze – –
Example: WL-LED100F-BL-SS
FIXTURE PERFORMANCE
Model # Lm Model # Lm Model # Lm Model # Lm Model # Lm
WL-LED100-C-SS 45 WL-LED100-C-BK 31 WL-LED100-C-WT 68 WL-LED100-C-BN 31 WL-LED100-C-BZ 32
WL-LED100-AM-SS 28 WL-LED100-AM-BK 19 WL-LED100-AM-WT 38 WL-LED100-AM-BN 19 WL-LED100-AM-BZ 21
WL-LED100-RD-SS 3 WL-LED100-RD-BK 2 WL-LED100-RD-WT 4 WL-LED100-RD-BN 2 WL-LED100-RD-BZ 2
WL-LED100-BL-SS 5 WL-LED100-BL-BK 3 WL-LED100-BL-WT 8 WL-LED100-BL-BN 3 WL-LED100-BL-BZ 4
WL-LED100F-C-SS 37 WL-LED100F-C-BK 25 WL-LED100F-C-WT 58 WL-LED100F-C-BN 25 WL-LED100F-C-BZ 27
WL-LED100F-AM-SS 20 WL-LED100F-AM-BK 14 WL-LED100F-AM-WT 29 WL-LED100F-AM-BN 14 WL-LED100F-AM-BZ 15
WL-LED100F-RD-SS 2 WL-LED100F-RD-BK 1.5 WL-LED100F-RD-WT 3 WL-LED100F-RD-BN 1.5 WL-LED100F-RD-BZ 2
WL-LED100F-BL-SS 4 WL-LED100F-BL-BK 3 WL-LED100F-BL-WT 6 WL-LED100F-BL-BN 3 WL-LED100F-BL-BZ 3
PRODUCT DESCRIPTION
Horizontal rectangle LEDme® Step Light. Designed for safety and style on stairways, patios, decks, balcony areas, walkways and building perimeters.
Features an architectural design. Energy efficient for long-lasting indoor and outdoor lighting solutions. Creates an attractive, romantic impression at night.
5"
3"
2a"
18"
front
12"
18"
x"
2"
side
1d"
22"
back
SPECIFICATIONS
Construction: Die-cast aluminum or 316 marine grade cast stainless steel
Power: Direct wiring, no remote driver needed. Input voltage: 120V or 277V
AC 50/60Hz
Light Source: 3000K CCT Samsung HV-AC High Power LED, CRI: 85
Optional color lenses. Total power consumption of 3.9W
Mounting: Fits into 2” × 4” J-Box with minimum inside dimensions of 3"L × 2"W × 2"H
Includes bracket for J-Box mount. See next page for spacing recommendations
Dimming: Dim to 10% with electronic low voltage (ELV) dimmer
Approved dimmers: Lutron Skylark SELV-300P-WH and Leviton Vizia VPE04
Standards: IP66, UL listed for wet locations
FINISHES
SS BK WT BN BZ
1450 Buffehr Creek Road
Exterior Light Fixture-Type B
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Avenue • Ontario, CA 91760
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAn 2014
Model: WL-LED100
LEDme® Step Light
Spacing Recommendations for Optimal Light Distribution
Stairs - Step Mount
Mount in center of stair as close to the upper tread as possible.
For best results use one light per step for steps narrower than 5'.
Stairs - Wall Mount
8"
11"
12"
22"
8"
Corridors / Hallways
12" - 18"
36" 36"
H HEVI LITE, INC.
9714 Variel Ave, Chatsworth, CA 91311
Tel., (818) 341-8091 - Fax (818) 998-1986
Web Site http://www.hevilite.com
HL-368
NOTE:
e
APPROVED:
PROJECT:
CATALOG NUMBER:
TYPE:
MADE IN THE USA
Fixture Finish Lamping Voltage Options/Access.
Wet/damp/dry location.
SPECIFICATIONS
DESCRIPTION:
Compact MR16 adjustable accent fixture with
integral straight glare shield. Suitable for
wet/damp/dry location installations.
MATERIAL:
Standard overall material is 6061 aluminum.
HL-368 - Machined Aluminum (Standard)
HL-368-1 - Machined Stainless Steel
HL-368-2b - Machined Brass
FINISH:
AA - Anodized Satin Aluminum
AP - Powder Coat Aluminum
BK - Powder Coat Black
BZ - Powder Coat Bronze
WT - Powder Coat White
N - Natural, for Stainless Steel and Brass
LAMPING:
Halogen Lamps
Lamp Type - 12V halogen MR16 lamp, bi-pin
GX5.3 base, 50W max, not included.
LED Lamps
Lamp Type - High output LED, warm white
(3000K CCT) standard, others available.
3LED - 3x1W LED, ave light output 260 lm
8LED - 3x2.7W LED, ave light output 457 lm
Optics
SP - Spot, 12º
NF - Narrow Flood, 24º
FL - Flood, 36º
VOLTAGE:
12 - 12 VAC output transformer required,
not included.
MOUNTING:
Fixture is designed with a 1/2" NPS
adjustable mounting stem.
OPTIONS:
Lenses/Louvers/Color Filters
LA-1 - Hexcell Louver (Black)
LA-2 - Prismatic lens
LA-3 - Linear spread lens
LA-4 - Soft focus lens (diffused)
LA-5 - Moonlight lens
LA-6 - Blue lens
See fixture accessories for more
information.
SAMPLE ORDER SPECIFICATION:
HL-368-2b-N-12-LA-2
RATING:
ORDER SPECIFICATION: _______________ - ________________ - _______________ - _______________ - _______________
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF HEVI LITE, INC. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF HEVI LITE, INC. IS PROHIBITED.
57
2 1/4"
79
3 1/8"
4 9/16"
116
1 3/8"
35
1450 Buffehr Creek Road
Exterior Light Fixture - Type C
WINDOW AND DOOR
CLADDING, WINDOW DIVIDE
AND PAINTED STEEL
STRUCTURE COLOR
UTILITY APPROVAL & VERIFICATION
This frm serves to verif that the proposed improvements will not impact any existing or proposed utility services, and
also to verif service availability and location fr new construction and should be used in conjunction with preparing your
utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted
to the fllowing utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COM
MENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact
The Town of Vail.
Subject Property Address: ___ ___ ______ _ Lot _ _ Block Subdivision: ______ _
Primary Contact/ Owner Representative: ___ ___ ____ _____ _ Phone: _______ _
Plans Dated: _______ _
Primary Contact/Owner Representative Signature
Authorized Signature
CENTURY LINK
970.328.8288 (tel)
970.328.8282 (fax)
Contacts: Kelly McClernon
kelly.mcclernon@centurylink.com
XCEL HIGH PRESSURE GAS
970.244.2788 (tel)
970.390.4777 (cell)
970.244.2661 (fax)
Contact: Ron Smith
ron.smith@xcelenerov.com
HOLY CROSS ENERGY
970.947.5425 (tel)
970.945.4081 (fax)
Contact: Jeff Vroom
jvroom@holycross.com
XCEL Energy
970.262.4032 (tel)
970.262.4038 (fax)
Contacts: Britt Mace
brittany.mace@xcelenergy.com
EAGLE RIVER WATER & SANITATION
DISTRICT
970.477.5449 (tel)
970.845. 7218 (fax)
Contact: Tug Birk
dbirk@erwsd.org
COMCAST CABLE
970.930.4713 (tel)
303.603.1004 (fax)
Contact: Michael Johnson
Michaeljohnson@cable.comcast.com
COOT (Only in COOT Right-of-way)
970.683.6284 (tel)
Contact: Dan Roussin
Daniel.roussin@dot.state.co.us
1. Utilit locations must be obtained befre digging.
NOTES:
Comments Date
2. A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way. Contact the
Public Work Department fr verification 970.479.2198.
3. It is the responsibilit of the utilit company and the applicant to resolve problems identified above.
4. The Primary ContactOwner Representative is required to submit any revised drawings to the above agencies for
re-approval & re-verification if the submited plans are altered in any way aſter the authorized signature date.
1450 Buffehr Creek Road 2 Cliffside
Micheal Suman / Suman Architects 970.471.6122
07.13.2017
Ron Smith HP Gas Clear 7-13-17
UTILITY APPROVAL & VERIFICATION
This frm serves to verif that the proposed improvements will not impact any existing or proposed utility services, and
also to verif service availability and location fr new construction and should be used in conjunction with preparing your
utility plan and scheduling installations. A site plan, including grading plan, floor plan, and elevations, shall be submitted
to the fllowing utilities for approval and verification. PLEASE ALLOW UP TO 2 WEEKS FOR APPROVAL OR COM
MENTS FROM THE UTILITY COMPANIES. If you are unable to obtain comments within that timeframe please contact
The Town of Vail.
Subject Property Address: ___________ __ Lot _ _ Block Subdivision: ______ _
Primary Contact/ Owner Representative: ___ ___ ____ _____ _ Phone: _______ _
Plans Dated: _______ _
Primary Contact/Owner Representative Signature
Authorized Signature
CENTURY LINK
970.328.8288 (tel)
970.328.8282 (fax)
Contacts: Kelly McClernon
kelly.mcclernon@centurylink.com
XCEL HIGH PRESSURE GAS
970.244.2788 (tel)
970.390.4777 (cell)
970.244.2661 (fax)
Contact: Ron Smith
ron.smith@xcelenerov.com
HOLY CROSS ENERGY
970.947.5425 (tel)
970.945.4081 (fax)
Contact: Jeff Vroom
jvroom@holycross.com
XCEL Energy
970.262.4032 (tel)
970.262.4038 (fax)
Contacts: Britt Mace
brittany.mace@xcelenergy.com
EAGLE RIVER WATER & SANITATION
DISTRICT
970.477.5449 (tel)
970.845. 7218 (fax)
Contact: Tug Birk
dbirk@erwsd.org
COMCAST CABLE
970.930.4713 (tel)
303.603.1004 (fax)
Contact: Michael Johnson
Michaeljohnson@cable.comcast.com
COOT (Only in COOT Right-of-way)
970.683.6284 (tel)
Contact: Dan Roussin
Daniel.roussin@dot.state.co.us
1. Utilit locations must be obtained befre digging.
NOTES:
Comments Date
2. A Revocable Right-of-Way Permit may be required for any improvements within a street right-of-way. Contact the
Public Work Department fr verification 970.479.2198.
3. It is the responsibilit of the utilit company and the applicant to resolve problems identified above.
4. The Primary ContactOwner Representative is required to submit any revised drawings to the above agencies for
re-approval & re-verification if the submited plans are altered in any way aſter the authorized signature date.
1450 Buffehr Creek Road 2 Cliffside
Micheal Suman / Suman Architects 970.471.6122
07.13.2017
7/20/17
If gas meter relocation is needed please apply
for service at xcelenergy.com
1 of 3 4/13/18
Service Calculation Clifftop Residence
Lighting Demand Load line neutral
Square Footage 5758 17274 17274
Small Appliance 2 1500 3000 3000
Laundry Circuit 2 1500 3000 3000
Total Load 23274 23274
First 3000w @ 100% 3000 3000
Next 3001 to 120000 @ 35% 7096 7095.9
Remainder @ 25% 0 0
Total Lighting Demand =======> 10096 10095.9
A/C and Heat Demand
Air Conditioning Load 240V Qua KVA Total
3hp 2.5 ton 2 4.5 9
0
Air Conditioning Total 9
Electric Heat Load 240V 0 0 0
0 0 0
Electric Heat Total 0
Air Conditioning Larger Total Heat vs. Air Conditioning=> 9000
omit electric heat
2 of 3 4/13/18
Appliance Fastened in Place Voltage Qua Watts Line Neutral
Dishwasher 120 2 1600 3200 3200
Disposal 120 2 1200 2400 2400
Refrigerator 120 1 1500 1500 1500
Under Cabinet Refrig 120 1 1000 1000 1000
Whirlpool Tub 120 2 1900 3800 3800
Hot Tub 240 1 5000 5000 0
Boiler Pump 120 6 200 1200 1200
Insta Hot 120 1 600 600 600
Microwave 120 1 800 800 800
compactor 120 1 1200 1200 1200
Fan blower 240 1 100 100 0
audio visual equipment 120 1 700 700 700
washer 120 1 1500 1500 1500
gas dryer 120 1 1500 1500 1500
Boiler 120 2 500 1000 1000
Steam Unit 240 1 8000 8000 0
Exhaust Fans 120 8 200 1600 1600
fan coil unit 240 3 800 2400 0
humidifier 240 1 1800 1800 0
fan coil unit 240 1 500 500 0
Heat Tape 240 8 2000 16000 0
0 0
0 0
0 0
Total Appliance (75% for 4 or more) 55800 22000 41850 16500
3 of 3 4/13/18
Elec.Clothes Dryer (5Kw min) 2 5000
Demand Factor % (220-18) 100% 10000 7000
Electric Cooking Equipment
Demand Factor Kw (220-19) 6.4 6400 4480
Largest Motor * 25% volts , watts 240 4500 1125 0
Total Demand line 78471
Total Demand Neutral 38076
Line Amperage Demand 327
Neutral Amperage 159
220-22 First 200 at 100% 159
Remainder at 70% 0
Neutral Amperage Demand 159
System Voltage H,L 240 120
Service Size ====>> 350
Conductor Type AL or CU AL
Wire Size per 310-16 note 3 500 AL XHHW
Service lateral length in feet 400
Resistance per ft. in ohms==> 21.2
Percentage of voltage drop 3
Wire Size per voltage drop 3@ 250 AL XHHW
Wire size 3@ 250 AL XHHW
LOWER DOOR SCHEDULE - CLIFFTOP RESIDENCE 04.02.18
DOOR ROOM TYPE SIZE HINGE TEMP MATERIAL GLASS NOTES
NO. NAME WxH (VIEW FROM OUT) U-VALUE
103 ELEVATOR HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR
104 HALL HINGED 3 0 x 8 0 R WOOD WOOD INTERIOR DOOR (OPTIONAL)
105 CLOSET 2 HINGED (2) 3 0x 8 0 R/L WOOD PAIR WOOD INTERIOR DOORS
106 BEDROOM 2 HINGED 3 0 x 8 0 R WOOD WOOD INTERIOR DOOR
107 BATH 2 HINGED 2 6 x 8 0 L WOOD WOOD INTERIOR DOOR
108 EXERCISE BARN DOOR (2) 2 6x 8 0 BARN WOOD WOOD INTERIOR DOORS, BARN DOOR HARDWARE
112 GAME ROOM SLIDING 6 5 1/2 x 8 0 RE:ELEV. T WOOD/GLASS 0.35 MULTI-SLIDE CUSTOM WOOD CLAD/GLASS EX. DOOR
113 BEDROOM SUITE 3 HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR
114 SUITE 3 CLOSET HINGED (2) 2 0x 8 0 R/L WOOD PAIR WOOD INTERIOR DOORS
115 BATH 3 HINGED 2 8 x 8 0 L WOOD WOOD INTERIOR DOOR
116 POWDER ROOM 3 HINGED 2 6 x 8 0 R WOOD WOOD INTERIOR DOOR
117 STORAGE ROOM 3 HINGED 2 8 x 8 0 L WOOD WOOD INTERIOR DOOR
118a MECH ROOM HINGED 3 0 x 8 0 L WOOD 20 MIN WOOD SOILD CORE-ACOUSTICAL SEALS
118b MECH ROOM HINGED 3 0 x 8 0 L WOOD 20 MIN WOOD SOILD CORE-WEATHER STRIPPING
MAIN DOOR SCHEDULE - CLIFFTOP RESIDENCE 04.02.18
DOOR ROOM TYPE SIZE HINGE TEMP MATERIAL GLASS NOTES
NO. NAME WxH (VIEW FROM OUT) U-VALUE
202 WINE ROOM HINGED 3 0 x 8 0 L T GLASS INTERIOR GLASS DOOR, WEATHER STRIPPING
203 ELEV. HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR
204 HALL HINGED 3 0 x 8 0 R WOOD WOOD INTERIOR DOOR
205 CLOSET 1 HINGED 2 6 x 8 0 R WOOD WOOD INTERIOR DOOR
206 BEDROOM SUITE 1 HINGED 3 0 x 8 0 R WOOD WOOD INTERIOR DOOR (OPTIONAL)
207 BATH 1 HINGED 2 6 x 8 0 L WOOD WOOD INTERIOR DOOR
208 STUDY BARN (2) 2 6x 8 0 BARN WOOD WOOD INTERIOR DOORS, BARN DOOR HARDWARE
210 GUEST BATHROOM HINGED 2 6 x 8 0 L WOOD WOOD INTERIOR DOOR
211 GUEST TOILET HINGED 2 4 x 8 0 L WOOD WOOD INTERIOR DOOR
212 UTILITY CLOSET HINGED 2 6 x 8 0 L WOOD WOOD INTERIOR DOOR
214 GUEST BEDROOM HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR
215 GUEST CLOSET HINGED 2 8 x 8 0 L WOOD WOOD INTERIOR DOOR
216 POWDER ROOM 2 HINGED 2 6 x 8 0 R WOOD WOOD INTERIOR DOOR
217 LAUNDRY HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR
218 LAUNDRY STORAGE HINGED 2 6 x 8 0 R WOOD WOOD INTERIOR DOOR
219 STORAGE ROOM 2 HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR
UPPER DOOR SCHEDULE - CLIFFTOP RESIDENCE 04.02.18
DOOR TYPE SIZE HINGE TEMP MATERIAL GLASS NOTES
NO. NAME WxH (VIEW FROM OUT) U-VALUE
302 ENTRY HINGED 3 8 x 8 1 1/2 L T WOOD/GLASS 0.35 CUSTOM WOOD/GLASS EXTERIOR DOOR
303 ELEV. HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR
304 DINING ROOM SLIDING 12 9 x 10 6 RE:ELEV. T WOOD/GLASS 0.35 MULTI-SLIDE CUSTOM WOOD CLAD/GLASS EX. DOOR
306 KITCHEN HINGED 3 0 x 8 4 R T WOOD/GLASS 0.35 WOOD CLAD/GLASS EXTERIOR DOOR
309 LIVING ROOM SLIDING 16 0 x 10 6 RE:ELEV. T WOOD/GLASS 0.35 LIFT/SLIDE CUSTOM WOOD CLAD/GLASS EX. DOOR
310 MASTER BATHROOM HINGED 2 6 x 8 0 L WOOD WOOD INTERIOR DOOR
311 MASTER TOILET HINGED 2 4 x 8 0 L WOOD WOOD INTERIOR DOOR
312 COAT CLOSET HINGED 2 6 x 8 0 L WOOD WOOD INTERIOR DOOR
314 MASTER BEDROOM SLIDING 10 0 x 8 0 RE:ELEV. T WOOD/GLASS 0.35 MULTI-SLIDE CUSTOM WOOD CLAD/GLASS EX. DOOR
315 MASTER CLOSET HINGED 2 8 x 8 0 L WOOD WOOD INTERIOR DOOR
316 POWER ROOM 1 HINGED 2 6 x 8 0 R WOOD WOOD INTERIOR DOOR
317a MUD ROOM HINGED 3 0 x 8 0 R WOOD 20 MIN WOOD SOILD CORE-WEATHER STRIPPING
317b MUD ROOM HINGED 3 0 x 8 0 R T WOOD/GLASS 0.35 WOOD CLAD/GLASS EXTERIOR DOOR
317c MUD ROOM HINGED 3 0 x 8 0 L WOOD WOOD INTERIOR DOOR
318 MUD CLOSET HINGED 3 0 x 8 0 R WOOD WOOD INTERIOR DOOR
319 GARAGE GARAGE DR 18 0 x 9 0 GARAGE DR T WOOD/GLASS 0.35 GARAGE DOOR
321 ELECTRICAL CLOSET HINGED 3 0 x 6 0 L WOOD CUSTOM WOOD DOOR WITH METER CUTOUT
REScheck Software Version 4.6.4
Compliance Certificate
Project Clifftop Residence
Energy Code: 2015 IECC
Location: Vail, Colorado
Construction Type: Single-family
Project Type: New Construction
Conditioned Floor Area: 5,486 ft2
Glazing Area 30%
Climate Zone: 6 (9248 HDD)
Permit Date:
Construction Site:
1450 Buffehr Creek Road
Vail, CO 81657
Owner/Agent:
Michael Suman
Suman Architects
michael@sumanarchitects.com
Designer/Contractor:
Permit Number:
Compliance: Passes using UA trade-off
8.5% Better Than Code Maximum UA: 915 Your UA: 837
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Above Grade Walls: Wood Frame, 16" o.c. 4,850 24.0 12.5 0.030 97
Windows: Wood Frame:Double Pane with Low-E 889 0.300 267
Garage Door: Solid 162 0.300 49
Glass Door: Glass 582 0.350 204
Slab: Slab-On-Grade:Unheated
Insulation depth: 6.0'
176 10.0 0.684 120
Flat Roof: Flat Ceiling or Scissor Truss 434 48.0 34.4 0.014 6
Pitched Roof: Flat Ceiling or Scissor Truss 1,268 48.0 34.4 0.014 18
Gaden Roof: Flat Ceiling or Scissor Truss 581 52.0 15.0 0.018 10
Basement Wall 1: Solid Concrete or Masonry
Wall height: 9.5'
Depth below grade: 9.5'
Insulation depth: 9.5'
1,384 6.2 6.2 0.048 66
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: Clifftop Residence
Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop
Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck
Page 1 of10
04/02/18Report date:
Project Title: Clifftop Residence
Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop
Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck
Page 2 of10
04/02/18Report date:
Inspection Checklist
Requirements: 0.0% were addressed directly in the REScheck software
REScheck Software Version 4.6.4
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2015 IECC
Section
#
& Req.ID
Pre-Inspection/Plan Review Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
103.1,
103.2
[PR1]1
Construction drawings and
documentation demonstrate
energy code compliance for the
building envelope. Thermal
envelope represented on
construction documents.
Complies
Does Not
Not Observable
Not Applicable
103.1,
103.2,
403.7
[PR3]1
Construction drawings and
documentation demonstrate
energy code compliance for
lighting and mechanical systems.
Systems serving multiple
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
Complies
Does Not
Not Observable
Not Applicable
302.1,
403.7
[PR2]2
Heating and cooling equipment is
sized per ACCA Manual S based
on loads calculated per ACCA
Manual J or other methods
approved by the code official.
Heating:
Btu/hr_____
Cooling:
Btu/hr_____
Heating:
Btu/hr_____
Cooling:
Btu/hr_____
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Clifftop Residence
Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop
Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck
Page 3 of10
04/02/18Report date:
Section
#
& Req.ID
Foundation Inspection Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
402.1.2
[FO1]1
Slab edge insulation R-value. R-_____
Unheated
Heated
R-_____
Unheated
Heated
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.2
[FO3]1
Slab edge insulation
depth/length.
_____ ft _____ ft Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.1
[FO4]1
Conditioned basement wall
insulation R-value. Where interior
insulation is used, verification
may need to occur during
Insulation Inspection. Not
required in warm-humid locations
in Climate Zone 3.
R-_____
R-_____
R-_____
R-_____
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2
[FO5]1
Conditioned basement wall
insulation installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
402.2.9
[FO6]1
Conditioned basement wall
insulation depth of burial or
distance from top of wall.
_____ ft _____ ft Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2.1
[FO11]2
A protective covering is installed
to protect exposed exterior
insulation and extends a
minimum of 6 in. below grade.
Complies
Does Not
Not Observable
Not Applicable
403.9
[FO12]2
Snow- and ice-melting system
controls installed.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Clifftop Residence
Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop
Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck
Page 4 of10
04/02/18Report date:
Section
#
& Req.ID
Framing / Rough-In Inspection Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
402.1.1,
402.3.4
[FR1]1
Door U-factor. U-_____ U-_____ Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.1,
402.3.1,
402.3.3,
402.3.6,
402.5
[FR2]1
Glazing U-factor (area-weighted
average).
U-_____ U-_____ Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.1.3
[FR4]1
U-factors of fenestration products
are determined in accordance
with the NFRC test procedure or
taken from the default table.
Complies
Does Not
Not Observable
Not Applicable
402.4.1.1
[FR23]1
Air barrier and thermal barrier
installed per manufacturer’s
instructions.
Complies
Does Not
Not Observable
Not Applicable
402.4.3
[FR20]1
Fenestration that is not site built
is listed and labeled as meeting
AAMA /WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC
400 that do not exceed code
limits.
Complies
Does Not
Not Observable
Not Applicable
402.4.5
[FR16]2
IC-rated recessed lighting fixtures
sealed at housing/interior finish
and labeled to indicate ≤2.0 cfm
leakage at 75 Pa.
Complies
Does Not
Not Observable
Not Applicable
403.2.1
[FR12]1
Supply and return ducts in attics
insulated >= R-8 where duct is
>= 3 inches in diameter and >=
R-6 where < 3 inches. Supply and
return ducts in other portions of
the building insulated >= R-6 for
diameter >= 3 inches and R-4.2
for < 3 inches in diameter.
Complies
Does Not
Not Observable
Not Applicable
403.3.3.5
[FR15]3
Building cavities are not used as
ducts or plenums.
Complies
Does Not
Not Observable
Not Applicable
403.4
[FR17]2
HVAC piping conveying fluids
above 105 ºF or chilled fluids
below 55 ºF are insulated to ≥R-
3.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
403.4.1
[FR24]1
Protection of insulation on HVAC
piping.
Complies
Does Not
Not Observable
Not Applicable
403.5.3
[FR18]2
Hot water pipes are insulated to
≥R-3.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
403.6
[FR19]2
Automatic or gravity dampers are
installed on all outdoor air
intakes and exhausts.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Clifftop Residence
Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop
Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck
Page 5 of10
04/02/18Report date:
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Clifftop Residence
Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop
Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck
Page 6 of10
04/02/18Report date:
Section
#
& Req.ID
Insulation Inspection Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
303.1
[IN13]2
All installed insulation is labeled
or the installed R-values
provided.
Complies
Does Not
Not Observable
Not Applicable
402.1.1,
402.2.5,
402.2.6
[IN3]1
Wall insulation R-value. If this is a
mass wall with at least ½ of the
wall insulation on the wall
exterior, the exterior insulation
requirement applies (FR10).
R-_____
Wood
Mass
Steel
R-_____
Wood
Mass
Steel
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2
[IN4]1
Wall insulation is installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Clifftop Residence
Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop
Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck
Page 7 of10
04/02/18Report date:
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
402.1.1,
402.2.1,
402.2.2,
402.2.6
[FI1]1
Ceiling insulation R-value. R-_____
Wood
Steel
R-_____
Wood
Steel
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.1.1.1,
303.2
[FI2]1
Ceiling insulation installed per
manufacturer’s instructions.
Blown insulation marked every
300 ft².
Complies
Does Not
Not Observable
Not Applicable
402.2.3
[FI22]2
Vented attics with air permeable
insulation include baffle adjacent
to soffit and eave vents that
extends over insulation.
Complies
Does Not
Not Observable
Not Applicable
402.2.4
[FI3]1
Attic access hatch and door
insulation ≥R-value of the
adjacent assembly.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
402.4.1.2
[FI17]1
Blower door test @ 50 Pa. <=5
ach in Climate Zones 1-2, and
<=3 ach in Climate Zones 3-8.
ACH 50 =_____ ACH 50 =_____ Complies
Does Not
Not Observable
Not Applicable
403.2.3
[FI4]1
Duct tightness test result of <=4
cfm/100 ft2 across the system or
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in
tests, verification may need to
occur during Framing Inspection.
_____ cfm/100
ft2
_____ cfm/100
ft2
Complies
Does Not
Not Observable
Not Applicable
403.3.2
[FI27]1
Ducts are pressure tested to
determine air leakage with
either: Rough-in test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the system including
the manufacturer’s air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer’s air
handler enclosure.
_____ cfm/100
ft2
_____ cfm/100
ft2
Complies
Does Not
Not Observable
Not Applicable
403.3.2.1
[FI24]1
Air handler leakage designated
by manufacturer at <=2% of
design air flow.
Complies
Does Not
Not Observable
Not Applicable
403.1.1
[FI9]2
Programmable thermostats
installed for control of primary
heating and cooling systems and
initially set by manufacturer to
code specifications.
Complies
Does Not
Not Observable
Not Applicable
403.1.2
[FI10]2
Heat pump thermostat installed
on heat pumps.
Complies
Does Not
Not Observable
Not Applicable
403.5.1
[FI11]2
Circulating service hot water
systems have automatic or
accessible manual controls.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Clifftop Residence
Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop
Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck
Page 8 of10
04/02/18Report date:
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
403.6.1
[FI25]2
All mechanical ventilation system
fans not part of tested and listed
HVAC equipment meet efficacy
and air flow limits.
Complies
Does Not
Not Observable
Not Applicable
403.2
[FI26]2
Hot water boilers supplying heat
through one- or two-pipe heating
systems have outdoor setback
control to lower boiler water
temperature based on outdoor
temperature.
Complies
Does Not
Not Observable
Not Applicable
403.5.1.1
[FI28]2
Heated water circulation systems
have a circulation pump. The
system return pipe is a dedicated
return pipe or a cold water supply
pipe. Gravity and thermos-
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
Complies
Does Not
Not Observable
Not Applicable
403.5.1.2
[FI29]2
Electric heat trace systems
comply with IEEE 515.1 or UL
515. Controls automatically
adjust the energy input to the
heat tracing to maintain the
desired water temperature in the
piping.
Complies
Does Not
Not Observable
Not Applicable
403.5.2
[FI30]2
Water distribution systems that
have recirculation pumps that
pump water from a heated water
supply pipe back to the heated
water source through a cold
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104ºF.
Complies
Does Not
Not Observable
Not Applicable
403.5.4
[FI31]2
Drain water heat recovery units
tested in accordance with CSA
B55.1. Potable water-side
pressure loss of drain water heat
recovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
Complies
Does Not
Not Observable
Not Applicable
404.1
[FI6]1
75% of lamps in permanent
fixtures or 75% of permanent
fixtures have high efficacy lamps.
Does not apply to low-voltage
lighting.
Complies
Does Not
Not Observable
Not Applicable
404.1.1
[FI23]3
Fuel gas lighting systems have
no continuous pilot light.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Clifftop Residence
Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop
Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck
Page 9 of10
04/02/18Report date:
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
401.3
[FI7]2
Compliance certificate posted. Complies
Does Not
Not Observable
Not Applicable
303.3
[FI18]3
Manufacturer manuals for
mechanical and water heating
systems have been provided.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Clifftop Residence
Data filename: J:\Jobs\2017 - Jobs\17075.00 - Clifftop
Residence\Mechanical\Calculations\Rescheck\17075-Rescheck.rck
Page 10 of10
04/02/18Report date:
2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
36.50Above-Grade Wall
12.50Below-Grade Wall
10.00Floor
82.38Ceiling / Roof
_______Ductwork (unconditioned spaces):
Glass & Door Rating SHGCU-Factor
0.30Window
0.35Door
Heating & Cooling Equipment Efficiency
_______Heating System:_________________________
_______Cooling System:_________________________
_______Water Heater:___________________________
Name: Date:
Comments
WINDOW SCHEDULE - CLIFFTOP RESIDENCE 04.02.18
WIN ROOM TYPE NOM. HINGE TEMP GLAZING U- NOTES
NO. NAME W/H (VIEW FROM OUT) VALUE
1 BEDROOM SUITE 3 C/FIX (2) 3 4 x 4 8 / 3 4 x 4 8 L/R LOW-E DOUBLE 0.30 EGRESS
2 REC ROOM C/FIX (2) 2 6x 5 8/6 4x 5 8 L/R LOW-E DOUBLE 0.30
3 EXERCISE C/FIX 2 6x 5 0/5 0x 5 0 R LOW-E DOUBLE 0.30 EGRESS
4 BEDROOM 2 C/FIX 2 6x 5 0/5 0x 5 0 L LOW-E DOUBLE 0.30 EGRESS
5A GUEST BEDROOM C/FIX (2) 3 4x 6 0/ 3 4x 6 0 L/R LOW-E DOUBLE 0.30 EGRESS
5B GUEST BATHROOM C 3 0x 6 0 R T LOW-E DOUBLE 0.30 ELECTRIFIED GLASS
6 GUEST BATHROOM C 3 0x 6 0 L T LOW-E DOUBLE 0.30 WATERPROOF FINISH IN SHOWER, ELECTRIFIED GLASS
7 FAMILY ROOM C/FIX (2) 2 6x 6 10/6 4x 6 10 L/R LOW-E DOUBLE 0.30
8 STUDY C/FIX 2 6x 5 0/5 0x 5 0 R LOW-E DOUBLE 0.30 EGRESS
9 BEDROOM SUITE 1 C/FIX 2 6x 5 0/5 0x 5 0 L LOW-E DOUBLE 0.30 EGRESS
10 MASTER BATHROOM C 3 0x 6 0 R T LOW-E DOUBLE 0.30 ELECTRIFIED GLASS
11 MASTER BATHROOM C 3 0x 6 0 L T LOW-E DOUBLE 0.30 WATERPROOF FINISH IN SHOWER, ELECTRIFIED GLASS
12 KITCHEN AWN/FIX 3 11x 5 6/3 11x 2 0 AWN LOW-E DOUBLE 0.30 MULL TO WDW 13, MOTORIZED OPERATION
13 KITCHEN AWN/FIX 3 11x 5 6/3 11x 2 0 AWN LOW-E DOUBLE 0.30 MULL TO WDW 12,14, MOTORIZED OPERATION
14 KITCHEN AWN/FIX 3 11x 5 6/3 11x 2 0 AWN LOW-E DOUBLE 0.30 MULL TO WDW 13, MOTORIZED OPERATION
15 STAIR FIX (2) 7 6x 1 7 1/2 T LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER
WINDOW SCHEDULE - CLIFFTOP RESIDENCE 04.02.18
WIN ROOM TYPE NOM. HINGE TEMP GLAZING U- NOTES
NO. NAME W/H (VIEW FROM OUT) VALUE
16 GUEST BEDROOM AWN (2) 4 0x 2 6 AWN LOW-E DOUBLE 0.30
17 MASTER BEDROOM AWN (2) 4 0x 2 6 AWN LOW-E DOUBLE 0.30
18 POWER ROOM 1 C 2 0x 3 6 L LOW-E DOUBLE 0.30
19 STAIR FIX/AWN (2) 5 1 3/4x 1 7 1/2 AWN LOW-E DOUBLE 0.30 FIELD VER. HEIGHT WITH MANF. MULLION COVER, MOTORIZED OPERATION
WINDOW SCHEDULE - CLIFFTOP RESIDENCE 04.02.18
WIN ROOM TYPE NOM. HINGE TEMP GLAZING U- NOTES
NO. NAME W/H (VIEW FROM OUT) VALUE
20 DINING FIX 8 0x 5 6/8 0x 1 10 LOW-E DOUBLE 0.30 MULL TO WDW 21
21 DINING C/FIX 3 7 3/4x 5 6/3 7 3/4x 1 10 L LOW-E DOUBLE 0.30 MULL TO WDW 20
22 ENTRY FIX/AWN (3) 3 1 1/2x 2 8 1/2 AWN T LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER
23 ENTRY FIX 3 1 1/2x 1 7 1/2 T LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER
24 ENTRY FIX 4 0x 1 7 1/2 T LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER
25 STAIR FIX (6) 3 6 1/4x 1 7 1/2 LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER
26 STAIR FIX (2) 7 6x 1 7 1/2 LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER
WINDOW SCHEDULE - CLIFFTOP RESIDENCE 04.02.18
WIN ROOM TYPE NOM. HINGE TEMP GLAZING U- NOTES
NO. NAME W/H (VIEW FROM OUT) VALUE
27 BEDROOM SUITE 1 AWN 6 0x 2 6 AWN T LOW-E DOUBLE 0.30
28 KITCHEN FIX 2 6x 5 4/2 6x 2 0 T LOW-E DOUBLE 0.30
29 KITCHEN F IX 3 4x 2 0 T LOW-E DOUBLE 0.30
30 KITCHEN FIX 2 6x 5 4/2 6x 2 0 T LOW-E DOUBLE 0.30
31 KITCHEN FOLDING (3) 3 0x 5 6 FOLDING T LOW-E DOUBLE 0.30 CUSTOM WINDOW, COOR'D WITH COUNTERTOP
31a KITCHEN AWN/FIX (3) 3 0x 2 0 AWN T LOW-E DOUBLE 0.30 MOTORIZED OPERATION
32 ENTRY FIX (3) 1 3 1/2x 2 8 1/2 T LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER
33 ENTRY FIX 1 3 1/2x 1 7 1/2 T LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER
34 STAIR FIX (6) 5 1 3/4x 1 7 1/2 LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER
35 STAIR AWN/FIX (2) 5 1 3/4x 1 7 1/2 AWN LOW-E DOUBLE 0.30 FIELD VERIFY HEIGHT WITH MANF. MULLION COVER
PERMIT FEE RECEIPT
Case # B18-0142
Date Printed: 05/17/2018
TOWN OF VAIL - FEES RECEIPT
Permit Summary
Case Number: B18-0142 Status: Approved
Permit Number: Date Started: 04/16/2018
Permit Type: Construction Subcases Single Family
Lot Number: 2
Property: 1450 BUFFEHR CREEK RD (210312102007) (210312102007)
Contacts
Contact Type: Applicant
Company Name: Vail Custom Builders
Full Name: Benno Scheidegger
Address: 0429 Edwards Access Road A207 Ed, CO 81657
Email: benno@vailcustom.com
Contact Type: Property Owner
Full Name: CLIFFTOP LLC
Address:
Permit Fees
Fee Information Account Amount
Construction Tax 110-0000.31060.00 $68,600.00
Will Call Fee 001-0000.31128.00 $15.00
Payment Information Date Paid Payment Type Amount
Will Call Fee 05/17/2018 Credit Card $15.00
Paid By: - Notes: visa-benno scheidegger
Construction Tax 05/17/2018 Credit Card $982.40
Paid By: - Notes: visa-benno scheidegger
FEE TOTAL $68,615.00
AMOUNT PAID $997.40
BALANCE DUE $0.00
05/17/2018 - 12:59:21 PM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657
1 / 1
ACTION FORM
Design Review Board (DRB)
Department of Community Development
75 South Frontage Road West
Vail, CO 81657
Tel: 970-479-2139
www.vailgov.com
Project Name: Clifftop LLC Residence 2017 Application Number: DRB17-0323
Application Type: New Construction Date Applied: 07/24/2017
Project Description:The redevelopment of 1450 Buffehr Creek Road with a new single family
residence.
CONTACTS
Contact Type: Applicant
Full Name: Beck Building Company (Kevin O'Donnell)
Address: P.O. Box 4030 Vail, CO 81658 Phone: 9709040087
Contact Type: Applicant
Full Name: Suman Architects (Michael Suman)
Address: 141 East Meadow Drive Suite 211 Vail, CO 81657 Phone: 9704716122
Contact Type: Property Owner
Full Name: CLIFFTOP LLC (Jim Stovall)
Address: Phone: None
Contact Type: Property Owner
Full Name: CLIFFTOP LLC (Don Brownstein)
Address: Phone: None
Project Address: 1450 BUFFEHR CREEK RD (210312102007) (210312102007)
Job Site Location:
Legal Description: Subdivision: CLIFFSIDE SUBDIVISION Lot: 2 Block:No
Data
Parcel Number: 210312102007
BOARDS/STAFF ACTION
Motion By: Kjesbo Action: Approved
Second By: Cahill
Vote: 4-0-0 Date: 08/16/2017
Conditions:
- Prior to submittal of a building permit application, the applicant shall revise the plans to show a minimum of
ten (10) serviceberry shrubs, 5-gallon container size, and three (3) aspen trees, 2-inch caliper, on the south
and southeast side of the proposed home.
- Approval of this project shall lapse and become void one (1) year following the date of final approval, unless
a building permit is issued and construction is commenced and is diligently pursued toward completion.
- Design Review Board approval shall not become valid for 20 days following the date of approval, pursuant
to the Vail Town Code, Chapter 12-3-3 Appeals.
- No changes to these plans maybe made without the written consent of Town of Vail staff and/or the
appropriate review committee(s).
Planner: Jonathan Spence