Loading...
HomeMy WebLinkAboutB18-0204_approved documents_1527107962.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Construction B18-0204 Issued: 05/23/2018 TOWN OF VAIL Property Information Address: 846 FOREST RD (210107216002) ( 210107216002 ) Unit #: Parcel Number: 210107216002 Legal Description: Subdivision: EAGLE RIVER WATER & SANITATION DISTRICT Lot: 1 PART OF R871144 MAP 03-18-04 R881472 EAS 06-22-04 R907750 EAS 03-03-05 R926962 EAS 08-22-05 Contacts Contact Type: Applicant Full Name: Eric Moberg Address: 770 Lindbergh Dr 501 Gypsum, CO 81637 Phone: 8776377397 Contact Type: Property Owner Full Name: EAGLE RIVER WATER & SANITATION DISTRICT Address: Phone: None Contractor Contractor Type: Mechanical Company: American Mechanical Services Of Denver, LLC State License #: Phone: 970-376-0423 Project Information Project Name: Eagle River Water & Sanitation District AC Units 2018 Project Description: Install larger Mitsubishi ductless split system in IT room. Fees Paid Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount: $120.00 Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount: $320.00 Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount: $80.00 Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope) Fee Amount: $5.00 Total Paid: $525.00 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. Job Name: System Reference: Date: Indoor Unit: PKA-A24KA7 Outdoor Unit: □ PUY-A24NHA7 □ PUY-A24NHA7-BS INDOOR UNIT FEATURES • Sleek, compact design • Simple installation • Vane setting for air flow direction control • Auto fan speed mode • Ideal for spaces such as server rooms, daycare centers, classrooms, churches, small offices, and more OUTDOOR UNIT FEATURES • Variable speed INVERTER-driven compressor • Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30) • Low ambient cooling down to -20ºF providing 100% capacity (only for PUY models with wind baffles installed) • 24-hour continuous operation (cooling mode) • High pressure protection • Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers • Superior energy and operational efficiency SUBMITTAL DATA: PKA-A24KA7 & PUY-A24NHA7(-BS) 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. P-SERIES Model Number Indoor Unit PKA-A24KA7 Outdoor Unit PUY-A24NHA7 PUY-A24NHA7-BS Cooling*1 Maximum Capacity Btu/h 24,000 Rated Capacity Btu/h 24,000 Minimum Capacity Btu/h 10,000 Maximum Power Input W 1,960 Rated Power Input W 1,960 Moisture Removal Pints/h 5.0 Sensible Heat Factor 0.77 Power Factor % 95.7 Efficiency SEER 21.4 EER *1 12.2 Electrical Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 198 – 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote controller V DC 12 Recommended Fuse/Breaker Size A 25 Recommended Wire Size (Indoor - Outdoor) AWG 14 Indoor Unit MCA A 1 Fan Motor Full Load Amperage A 0.36 Fan Motor Output W 56 Airflow Rate, Dry CFM 635-705-775 Airflow Rate, Wet CFM 570-635-700 External Static Pressure in.WG n/a Sound Pressure Level dB(A) 39-42-45 Drain Pipe Size In. (mm) 5/8 (16) Condensate Lift Mechanism, Max. Distance In. (mm) n/a Heat Exchanger Type Plate fin coil External Finish Color White Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm) 46-1/16 (1170) D: In. (mm) 11-5/8 (295) SPECIFICATIONS: PKA-A24KA7 & PUY-A24NHA7(-BS) Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. Model Number Indoor Unit PKA-A24KA7 Outdoor Unit PUY-A24NHA7 PUY-A24NHA7-BS H: In. (mm) 14-3/8 (365) Package Dimensions W: In. 51 D: In. 18-8/16 H: In. 14-4/16 Unit Weight Lbs. (kg) 46 (21) Package Weight Lbs. 53 Indoor Unit Operating Temperature range Cooling Intake Air Temp (Maximum / Minimum) °F 90 DB, 73 WB / 66 DB, 59 WB Outdoor Unit MCA A 19 MOCP A 26 Fan Motor Full Load Amperage A 0.40 Fan Motor Output W 86 Airflow Rate CFM 1,940 Refrigerant Control Electronic Expansion Valve Heat Exchanger Type Cross fin Sound Pressure Level, Cooling*1 dB(A) 47 Sound Pressure Level, Heating*2 dB(A) 48 Compressor Type INVERTER-driven twin rotary Compressor Model SNB172FWHM1 Compressor Rated Load Amps A 7 Compressor Locked Rotor Amps A 11 Compressor Oil Type // Charge oz. FV50S // 23 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater n/a Unit Dimensions W: In. (mm) 37-13/32 (950) D: In. (mm) 13 + 1-3/16 (330 + 30) H: In. (mm) 37-1/8 (943) Package Dimensions W: In. 40-15/16 D: In. 17-11/16 H: In. 40-11/16 SPECIFICATIONS: PKA-A24KA7 & PUY-A24NHA7(-BS) Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. Model Number Indoor Unit PKA-A24KA7 Outdoor Unit PUY-A24NHA7 PUY-A24NHA7-BS Unit Weight Lbs. (kg) 151 (68) Package Weight Lbs. (kg) 176 (80) Outdoor Unit Operating Temperature Range Cooling Intake Air Temp (Maximum / Minimum) °F 115 DB / -20* DB Refrigerant Type R410A Charge Lbs, oz 7 lbs, 11 oz Piping Gas Pipe Size O.D. (Flared) In.(mm) 5/8 (15.88) Liquid Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52) Maximum Piping Length Ft. (m) 225 (69) Maximum Height Difference Ft. (m) 100 (30) Maximum Number of Bends 15 AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) *1 Cooling (Indoor // Outdoor) °F 80°F DB, 67°F WB // 95°F DB, 75°F WB Notes *Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -20°F - 115°F. Refer to wind baffle documentation for further information. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures SEACOAST PROTECTION • External Outer Panel: Phosphate coating + Acrylic-Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly; Valve Bed: Epoxy resin coating (at edge face) • “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Notes: SPECIFICATIONS: PKA-A24KA7 & PUY-A24NHA7(-BS) Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. 3-Pole Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] □ TAZ-MS303 Drain Pan Level Sensor (Control for indoor unit shut off to prevent drain pan overflow) □ DPLS2 MaxiBlue Advanced Blue Diamond Mini-Condensation pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] □ X87-711 - 110 MaxiBlue Advanced Blue Diamond Mini-Condensation pump w/ Reservoir & Sensor (208/230V) up to 48,000 Btu/h [recommended] □ X87-721 - 208/230 Extension Cord for Blue Diamond Pump □ C13-103 Sauermann Mini-Condensation pump (115V) □ SI30-115 Sauermann Mini-Condensation pump (230V) □ SI30-230 MegaBlue Blue Diamond Condensate Pump (110-230V) □ X87-835 Remote Sensor (extensible) □ PAC-SE41TS-E Connector for CN32 (remote ON/OFF) □ PAC-SE55RA-E Connector for CN152 (Back up heating) □ PAC-SE59RA-E External fan / Heater control relay adapter □ CN24RELAY-KIT-CM3 Backlit, wall-mounted, wireless □ MHK1 Wireless Remote Controller □ MRCH1 Wireless Receiver □ MFH1 Portable Central Controller □ MCCH1 Outside Air Sensor □ MOS1 Wireless adapter □ PAC-USWHS002-WF-1 BACnet® and Modbus Interface □ PAC-UKPRC001-CN-1 Wall-mounted, Wired □ PAC-YT53CRAU-J Wired Remote Controller □ PAR-33MAA-J T-STAT Interface □ PAC-US444CN-1 Simple remote controller □ PAC-YT53CRAU Wireless Remote Controller □ PAR-FL32MA-E Wire for Remote ON/OFF with CN32 connector □ PAC-715AD Lockdown Bracket for wireless, hand-held, remote controllers □ RCMKP1CB ACCESSORIES: PKA-A24KA7 Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. Twinning Distribution Pipe (50:50) □ MSDD-50TR-E Air Outlet Guide □ PAC-SG59SG-E Front Wind Baffle □ WB-PA5 Side Advanced Wind Baffle □ WB-SD5 Rear Advanced Wind Baffle □ WB-RE5 Hail Guard □ HG-A6 Drain Socket □ PAC-SG61DS-E Centralized Drain Pan □ PAC-SG64DP-E Control/Service Tool □ PAC-SK52ST Wall Mounting Bracket (Powder-coated Steel) □ QCWB2000M-1 Wall Mounting Bracket (316 Series Stainless Steel) □ QSWBSS M-NET Control Adapter for Building Management System □ PAC-SF83MA-E Outdoor Unit Mounting Pad 24" x 42" x 3" □ ULTRILITE2 Outdoor Unit 3-1/4 inch Mounting Base - Pair (Plastic) □ DSD-400N MiniSplit Mounting Stand-Single Fan Models - 12" □ QSMS1201M MiniSplit Mounting Stand-Single Fan Models - 18" □ QSMS1801M MiniSplit Mounting Stand-Single Fan Models - 24" □ QSMS2401M 3/8 x 5/8 x 10' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-10 3/8 x 5/8 x 15' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-15 3/8 x 5/8 x 30' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-30 3/8 x 5/8 x 50' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-50 3/8 x 5/8 x 65' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-65 3/8 x 5/8 x 100' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-100 ACCESSORIES: PUY-A24NHA7(-BS) Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. PKA-A24KA7 Front side 46-1/16(1170) 9-1/2(241)33-21/32(855) 2-29/32(74) 14-3/8(365) Emergency operation switch(cooling/heating) Terminal block for Outdoor unit Terminal block forMA-remote controller Front side(Grille open) Terminal block for power supply (option) Filter hook 6-1/16(154) 4-27/32(123) 18-31/32(482)Liquid pipe 17-15/32(444)Gas pipeDrain hose 5-9/32(134)Min.9/32(7)Center measurement hole[3/32([2.5) Knockout hole forrear piping 75-[3/16([5.1)Tapping screw hole Mount board Wall hole forright rear piping Indoor unit outline 4-[11/32([9) Bolt hole 1/8(3)R1-15/32(R37.5)2-1/8(54)05/8(15.5)0 17-9/32(439)017-9/32(439)15-1/8(384)13/32(10)20-3/8(517.4)17-7/8(454)16-3/32(408.5)15-1/8(384)14-11/32(364)12-3/8(314)4-11/32(110) 2-3/8(60)13/32(10)18-5/16(465.5)17-7/8(454)16-3/32(408.5)15-1/8(384.5)14-11/32(364)12-3/8(314)4-11/32(110) 2-3/8(60)1-1/4(32) 12-5/32(308.5) 31/32(25) 11-1/2(292) 11(279.5) 9-17/32(242) 7-9/16(192) 5-19/32(142) 4-29/32(125)4-19/32(117)3-15/16(100)2-15/16(75)1-31/32(50)15-1/8(384)013-3/4(349.2)16-15/16(430.5)1/2(12.5) 11-1/2(292)10-13/32(264)9-1/32(229.5)8-17/32(217) 6-9/16(167) 5-3/32(129.5) 4-1/8(104.5)3-7/16(87.5)2-15/32(62.5)1-15/32(37.5)1/2(12.5) 2-1/8(54) 31/32(25) 0 12-1/4(311)8-17/32(216.5)13-11/32(339) 20-7/8(530.5)7-7/16(189)13-11/32(339)17-11/16(449.2)23-1/32(585)23-1/32(585)A 5/16(7.8)3-1/32(77)2-5/8(67)2-9/16(65) B Knockout hole for piping 13/32(10.7)2-9/16(65)3-1/32(77) 3-7/16(87) C 5/16(7.8)2-9/16(65)3-1/32(77)2-5/8(67)Louver(manual) Vane(auto) Knockout holefor lower piping Under side BB Receiver DEFROST/STAND BY lamp Operation lamp 2-19/32(66)23/32(18)1-1/4(32)2-3/32(53)1-3/16(30) 1-3/8(35) Mount board C Knockout holefor right piping Right side 11-5/8(295) 3/16(5) Left side A Knockout holefor left piping Top side 2-9/16(65.2)5-17/32(140.3)7/16(11)17(431.7)16-11/16(423.7) Air outlet Air inlet Min.1-7/8(48)Min.9-27/32(250)Required space(Indoor unit) Min.3-31/32(100.5)Min.8-21/32(220) Min.2-1/16(52.3) 3 2 1 Refrigerant pipe: 3/8 O.D([9.52) Refrigerant pipe: 5/8 O.D([15.88) 5/8([16) O.D3 Drain hose Piping connection 1 Liquid pipe 2 Gas pipeThrough hole [2-15/16 ([75) [2-15/16~[3-5/32([75~[80) Sleeve(purchased locally) Flared connection: 5/8F Flared connection: 3/8F Effective length: 23-1/32 (585) Unit: inch (mm) DIMENSIONS: PKA-A24KA7 & PUY-A24NHA7 (-BS) Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. PUY-A24NHA7(-BS)Z-A24NHA7-BS PUZ-A30NHA7-BS PUY-A24NHA7-BS PUY-A30NHA7-BSDrain hole(5-ø33<1-5/16>) Bottom piping hole(knockout) 145<5-23/32> 145 <5-23/32>145 <5-23/32>220 <8-21/32> 30<1-3/16> 81<3-3/16> 219 <8-5/8>71<2-13/16>71<2-13/16> Rear piping cover Front piping cover 2-12×36 oval holes(Foundation Bolt M10<W3/8>) Air Discharge Rear Air Intake Side Air Intake 2-U Shaped notched holes(Foundfation Bolt M10<W3/8>) Installation Feet 330<13>175<6-7/8> 57<2-1/4> 41<1-5/8>417 <1-1/32>28<1-3/32> 370<14-9/16>19<3/4>25<31/32> 70<2-3/4> 175<6-7/8> 600<23-5/8> 40<19/32> 53<2-3/32> 61<2-13/32> 0 Side Air Intake Handlefor moving Air Intake Rear Air Intake Handle formoving Min.100mm<3-15/16>Min. 500mm<19-11/16> 2 1 Handlefor moving Handle for moving Service panel Earth terminal Left ... Power supply wiringReight ... Indoor/Outdoor wiring Terminal Connections 669<26-11/32> 950<37-13/32> 322<12-11/16> 943 <37-1/8>473 <18-5/8>23 <29/32> *1 447<17-5/8>*1 431<16-31/32> Min. 10mm<3/8>Min. 10mm<3/8>FREEWhen installing the conduit, Set the attachment to the inner side of each panel. 1/2 Conduit attachment 2-ø22.2<7/8> 31<1-7/32> 74<2-19/32> 40<1-9/16> 2 1 ... Refrigerant GAS pipe connection (FLARE)ø15.88(5/8F)... Refrigerant LIQUID pipe connection (FLARE)ø 9.52(3/8F) *1... Indication of STOP VALVE connection location. Example of Notes Power supply wiring hole(2- ø27<1-1/16>knockout) Rear trunking hole (knockout) Rear piping hole (knockout)63<2-1/2>73<2-7/18> 23<29/32> 55 <2-3/16>27<1-1/16> 92<3-5/18> 65<2-9/16> 45<1-25/32> 40<1-9/16> ø92<3-5/8> Power supply wiring hole (2-ø27knockout) Front trunking hole (knockout) Front piping hole(knockout) 45<1-25/32> 65<2-9/16> 92<3-5/8> 40<1-9/16> 63<2-1/2> 23<29/32> 73<2-7/8> 55<2-3/16> 27<1-1/16> 92<3-5/8> Right piping hole(knockout)Right trunking hole (knockout) Power supply wiring hole(2-ø27knockout) 19<3/4> 55<2-3/16>23<29/32> 27 <1-1/16>92<3-5/8> 92<3-5/8> 40<1-9/16>75<2-31/32> 73<2-7/18> 63<2-1/2>92<3-5/8> Piping knockout Hole Details Max.<Foundation bolt height>30<1-3/16>Min. Min.Servicespace 10<13>Min. 500 <19-11/16>500 <19-11/16>100 <3-15/16>Min.Dimensions of space neededfor service access areshown in the below diagram. Please secure the unit firmlywith 4 foundation (M10<W3/8>) bolts.(Bolts and washers must bepurchased locally.) Piping and wiring connectionscan be made from 4 directions:FRONT,Right,Rear and Below. 4 PIPING-WIRING DIRECTIONS 3 FOUNDATION BOLTS 2 SERVICE SPACE 1 FREE SPACE (Around the unit) The diagram below shows abasic example.Explantion of particular details aregiven in the installation manuals etc. ø ø FOUNDATION Unit: mm<in> FORM# PKA-A24KA7 / PUY-A24NHA7(-BS) - 201709 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: PKA-A24KA7 & PUY-A24NHA7 (-BS) Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc.