HomeMy WebLinkAboutDRB18-0061_Approved Documents_1525124879.pdfACTION FORM Design Review Board (DRB) Department of Community Development 75 South Frontage Road West Vail, CO 81657 Tel: 970-479-2139 www.vailgov.com Project Name: Boyd Residence 2018 Application Number: DRB18-0061 Application Type: Exterior Alteration Date Applied: 03/06/2018 Project Description: Add Single Zone AC System to master bedroom CONTACTS Contact Type: Applicant Full Name: Skyline Mechanical INC (Justin Nielsen) Address:134 Air Park DR #2C 134 Air Park DR #2C Gypsum, CO 81637 Phone: 9705246809 Contact Type: Property Owner Full Name: BOYD, MICHAEL J. & MARIAN M. Address: Phone: None Project Address: 9 VAIL RD 1B (210107106002 1B) (210107106002) Job Site Location: 1B Legal Description: Subdivision: VAIL VILLAGE FILING 2 Lot: B Block:No Data Parcel Number: 210107106002 BOARDS/STAFF ACTION Motion By: Action: Staff Approved Second By: Vote: Date: 04/27/2018 Conditions: - All exposed metal flashing, trim, flues, vents, and rooftop mechanical equipment shall be anodized, painted (adjacent facade/roof material color or flat black), or capable of weathering so as to be non-reflective pursuant to Section 14-10-5C, Building Materials and Design, Vail Town Code, pror to requesting final inspections. - Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. - Design Review Board approval does not constitute a permit for building. Please consult with Town of Vail building personnel prior to construction activities. - Design Review Board approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12-3-3 Appeals. - No changes to these plans maybe made without the written consent of Town of Vail staff and/or the appropriate review committee(s). - Screening fence shall be painted to match the background color. Planner: Chris Neubecker at @ it Linesets through garage @ Ceiling Outdoor unit location A on DRAIN aIndoor Unit M-SERIES Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Job Name: System Reference: Date: SUBMITTAL DATA: MSY-GL12NA-U1 & MUY-GL12NA-U1 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM Indoor Unit: MSY-GL12NA-U1 Outdoor Unit: MUY-GL12NA-U1 Wireless Remote Controller ACCESSORIES: Indoor Unit □Condensate Pump (BlueDiamond X87-711/721; 115/230V) □Condensate Pump (Sauermann SI30-115/230; 115/230V) □Anti-Allergy Enzyme Filter (MAC-408FT-E) □Drain Pan Level Sensor (DPLS2) Outdoor Unit □Outdoor Mounting Pad (ULTRILITE1) □Drain Pan Heater (MAC-640BH-U) □3-1/4” Mounting Base [Pair] (DSD-400P) □Drain Pan Socket (MAC-860DS) □Air Outlet Guide (MAC-889SG) □Wall Mounting Bracket (QSWB2000M-1) Controls □Wireless Controller (MHK1) □Wired Remote Controller PAR-32MAA (Requires MAC-333IF-E) □Wireless Interface for kumo cloud™ (PAC-USWHS002-WF-1) □Thermostat Interface (PAC-US444CN-1) SPECIFICATIONS: Rated Conditions (Capacity / Input) Cooling1 Btu/h / W 12,000 / 920 Capacity Range Minimum Maximum Cooling1 Btu/h 1,500 13,600 1 Cooling | Indoor: 80º F(27º C)DB / 67º F(19º C)WB; Outdoor: 95º F(35º C)DB / 75º F(24º C)WB* * Rating Conditions per AHRI Standard: Operating Conditons (Indoor Intake Air Temp.) (Max./ Min.) Cooling2 90º F (32º C) DB / 67º F (19º C) DB Operating Conditons (Outdoor Intake Air Temp.) (Max./ Min.) Cooling2 115º F (46º C) DB / 14º F (-10º C) DB 2 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. AHRI Efficiency Ratings SEER 23.1 Energy Star® Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Electrical Power Requirements 208 / 230V, 1-Phase, 60 Hz Minimum Circuit Ampacity (MCA) Indoor / Outdoor A 1 / 7 Indoor Unit Blower Motor (ECM) F.L.A.0.76 Blower Motor Output W 30 SHF / Moisture Removal 0.740 / 2.5 pt./h Field Drainpipe Size O.D. In.(mm)5/8 (15) Outdoor Unit Compressor DC INVERTER-driven Twin Rotary Fan Motor (ECM) F.L.A. 0.50 Airflow Rate (Quiet - Lo - Med - Hi - Super Hi) Indoor (Cooling) DRY CFM 145-170-237-321-399 WET 109-134-201-286-364 Outdoor 1,229 / 1,172 Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi) Indoor Cooling dB(A) 19-22-30-37-45 Outdoor Cooling 49 External Dimensions Indoor (H x W x D) In.(mm) 11-5/8 x 31-7/16 x 9-1/8 (295 x 798 x 232) Outdoor (H x W x D)21-5/8 x 31-1/2 x 11-1/4 (550 x 800 x 285) Net Weight Indoor Lbs.(kg) 22 (10) Outdoor 81 (37) External Finish Indoor Munsell 1.0Y 9.2 / 0.2 Outdoor Munsell No. 3Y 7.8 / 1.1 Refrigerant R410A; 2 lb. 9 oz. Refrigerant Piping (Flared) Liquid (High Pressure) In.(mm) 1/4 (6.35) Gas (Low Pressure) 3/8 (9.52) Max. Total Refrigerant Pipe Length (Height Diff.) Ft. (m) 40 (12) Max. Total Refrigerant Pipe Length (Length.)65 (20) Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com FORM# MSY-GL12NA-U1 / MUY-GL12NA-U1 - 201611 DIMENSIONS: MSY-GL12NA-U1 & MUY-GL12NA-U1 MSY-GL12NA-U1 MUY-GL12NA-U1 Unit: in. (mm)clear *1*1 4 in. (100 mm) or more when front and sides of the unit are clear *2 When any 2 sides of left, right and rear of the unit are clear holes (GL09/12/15NA)(GL09/12/15NAH) REQUIRED SPACE Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 4 in. (1 00 mm) or mor e 14 in. (350 mm) or mor e8 in . (200 mm ) o r mo r e *2 4 in. (100 mm) or more Unit: in. (mm) MSY-GL09NA MSY-GL12NA MSY-GL15NA PipingInsulation ø1 - 3/8 O.D Liquid line ø1/4 19 - 11/16 (Flared connection ø1/4) Gas line ø3/8 16 - 15/16(Flared connection: ø3/8 (GL06/09/12NA), ø1/2 (GL15NA)) Drain hose Insulation ø1-1/8 O.D Connected part ø5/8 O.D PLANNING FEE RECEIPT Case # DRB18-0061 Date Printed: 04/30/2018 TOWN OF VAIL - FEES RECEIPT Planning Summary Type: Design Review Board (DRB) Submittal Date: 03/06/2018 Subcases: Exterior Alteration Bond Expire Date: Description of Work: Add Single Zone AC System to master bedroom Property Information Address: 9 VAIL RD 1B (210107106002 1B) Tax ID: 210107106002 Owner: BOYD, MICHAEL J. & MARIAN M. Contacts Contact Type: Applicant Company Name: Skyline Mechanical INC Full Name: Justin Nielsen Address: 134 Air Park DR #2C 134 Air Park DR #2C Gypsum, CO 81637 Email: justin@skylinemechanical.com Contact Type: Property Owner Full Name: BOYD, MICHAEL J. & MARIAN M. Address: Planning Fees Fee Information Account Amount DRB - Exterior Alteration 001-0000.31122.00 $250.00 Payment Information Date Paid Payment Type Amount DRB - Exterior Alteration 03/06/2018 Credit Card $250.00 Paid By: Web payment - Notes: Transaction ID: 40580612790 , auth code: 06907D FEE TOTAL $250.00 AMOUNT PAID $250.00 BALANCE DUE $0.00 04/30/2018 - 3:44:31 PM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657 1 / 1 April 24, 2018 Marian and Mike Boyd 31336 Burn Lane Evergreen CO 80439 Re: Request to install air conditioning in Unit 11 Dear Marian and Mike: The Board of Directors reviewed your application to install air conditioning in its meeting April 23, 2018. The review was based on the prior application reviewed March 26 as modified by Justin Nielsen of Skyline Mechanical Inc. in e-mails dated April 20: − Plan M-1 dated March 7, 2018 (attached) − Representations made by Justin Nielsen of Skyline Mechanical Inc. regarding structural engineering recommendation in e-mail April 20: “His [Structural engineer] reccomendation was the same as our plan & that is to simly enlarge a Existing pentration & not create a new one. this will be easy to do. since we are not bring drain through the slab now our required hole will be 1" round or less. we can simply chip the fill oaround the existing pentration for our lines & Re Groute when complete. With your approval we would like to move forward as proposed please advice.” [sic] On file with the Association is a signed Application for Unit Remodel and a Construction Agreement signed by Skyline Mechanical Inc. the Construction Agreement will be fully executed when the owners return to Colorado. A Certificate of Liability for Skyline Mechanical Inc. will also be required before construction may begin. The application is approved with the following conditions: − The specific location and orientation of the outside unit and location of penetrations of the exterior wall of the building are to be marked in place and reviewed by the Association before the slab is laid and the penetrations made. Penetrations must be behind and hidden by the outside unit. − Confirmation of the capability of the house electrical system to support the 208/223 Volt single phase specifications for the exterior unit. AEC can confirm. − Exterior compressor unit: mounting is to incorporate vibration dampening − Exterior compressor unit must be screened from view from the patio / pool area with slat fencing painted grey to match the wood trim of the building or other screening approved by the Association. − All plumbing and electrical conduit will be contained entirely within Unit 11 with the exception of the proposed “line hide pipe” to be located in the garage as shown on plan M-1. − The pre-stressed concrete floor plate may not be trenched. − Condensate from the interior unit will be drained to the sink drain as shown on plan M-1. − No interior units may interfere with the operation of the fire sprinkler system. − The owner is responsible for all upgrades to electrical service to support this installation. − The low voltage connection between the thermostat and the baseboard heating zone valves in the bedroom and living room is in a serial link to other units and must be preserved. − Copies of all permits and satisfaction of permits are to be provided to the Association. All approvals are subject to the terms of the Construction Agreement, Rules and Regulations, Architectural Change and Design Review of Unit Modifications, Common Element Modification Policy and Universal Policy on Unit Renovations, all of which can be found on the 9 Vail Road website. All logistics regarding parking, trash removal, construction materials delivery and building access must be coordinated with Tom Saalfeld before any work starts. Please make sure that all vehicles on site indicate “Unit 11” on their dash. This letter also documents to Town of Vail Community Development department the approval of this proposal by the 9 Vail Road Condominiums Board of Directors. Any further application for changes to the building permit will require an HOA approval letter specific to those applications. Any further changes requiring a review of “Minor Exterior Alteration” will require an HOA approval letter for each change element. Sincerely, For the Board of Directors Cc: Alfredo Catan, 9 Vail Road Board of Directors Debbie Ford, 9 Vail Road Board of Directors Rhoda Kaplan, 9 Vail Road Board of Directors Pat Parrish, 9 Vail Road Board of Directors Tom Saalfeld, Ptarmigan Management Christopher Jarecki, Town of Vail Community Development Chris Neubecker, Town of Vail Community Development Justin Nielsen, Skyline Mechanical Inc.