Loading...
HomeMy WebLinkAboutDRB18-0114_approved plans_1525291084.pdf1. ALL DISTRIBUTIONS OF THESE DRAWINGS BY THE GENERAL CONTRACTOR SHALL INCLUDE ALL ADDITIONAL DOCUMENTS ASSOCIATED WITH THIS ISSUE. THESE DOCUMENTS INCLUDE, BUT ARE NOT LIMITED TO, PROJECT MANUAL, SPECIFICATIONS, AND DETAIL MANUAL. FURTHERMORE, NONE OF THE ADDITIONAL DOCUMENTS SHALL BE DISTRIBUTED WITHOUT THESE DRAWINGS. 2. IT IS THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS TO ESTABLISH A STANDARD OF QUALITY. THE ARCHITECT RESERVES THE RIGHT TO TAKE EXCEPTIONS TO METHODS AND MATERIALS NOT REFLECTED HEREIN. 3. WORK SHALL BE PERFORMED IN A WORKMANLIKE OR CRAFTSMANLIKE MANNER TO THE SATISFACTION OF THE OWNER. 4. THE DRAWINGS SHALL NOT BE SCALED TO DETERMINE CONSTRUCTION DIMENSIONS. THE CONTRACTOR AND EACH SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO EXECUTION OF THE WORK, AND SHALL BE RESPONSIBLE FOR THE CORRECT AND ACCURATE LAYOUT AND CONSTRUCTION OF THE PROJECT. 5. DIMENSIONS ARE TO FACE OF STUD OR TIMBER, CENTERLINE OF TIMBER AND FACE OF CONCRETE, UNLESS NOTED OTHERWISE. 6. DOOR SIZES ARE NOTED AS 2670, WHICH IS A 2'-6"x7'-0" DOOR. 7. REFER TO PLANS SECTIONS AND ELEVATIONS FOR WINDOW LOCATIONS AND SIZES. SIZES ARE NOTED AS 4848 WHICH IS A 48"x48" WINDOW. WINDOWS ARE TO BE ALUMINUM CLAD WOOD WINDOWS. 8. COORDINATE ELECTRICAL AND MECHANICAL WORK WITH STRUCTURAL FRAMING. 9. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO TOILETS, BATH ACCESSORIES, CEILING AND WALL MOUNTED ELECTRICAL FIXTURES, SHELVES, CLOSET RODS, CABINETRY, COUNTER TOPS, STAIR HANDRAILS AND FALSE BEAMS. 10. ALL NON 90 DEGREE ANGLES ON PLANS ARE 45 DEGREES UNLESS OTHERWISE NOTED. 11. IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. FLOOR PLANS TAKE PRECEDENCE. 12. ALL ARCHES ARE TO HAVE A RADIUS THAT EQUALS THE WIDTH OF THE OPENING. THE SPRING LINE OF THE ARCH IS LOCATED AT 7'-0" AFF UNLESS NOTED OTHERWISE.. 13. WOOD/TIMBER MEMBERS NOTED AS "ACTUAL" REFER TO THE ACTUAL FINISHED DIMENSION OF THE MEMBER. FOR EXAMPLE: "4X12 ACTUAL" REFERS TO A MEMBER THAT MEASURES 4 INCHES WIDE BY 12 INCHES DEEP. MEMBERS NOT NOTED AS "ACTUAL" REFER TO THE NOMINAL FINISHED DIMENSION OF THE MEMBER. FOR EXAMPLE: "4X12" REFERS TO A MEMBER THAT MEASURES 3 1/2 INCHES WIDE BY 11 1/4 INCHES DEEP. REFER TO SPECIFICATIONS FOR SURFACE TEXTURE AND FINISH. 14. INSTALL PERFORATED PIPE PERIMETER DRAIN SYSTEM AND SOLID PIPE UNDER DRAIN SYSTEM AS REQUIRED. REFERENCE SOILS REPORT FOR ADDITIONAL REQUIREMENTS. SLOPE SYSTEM TO DRYWELL OR DAYLIGHT. ALL DOWNSPOUTS ATTACHED TO DRAIN SYSTEM AND HEAT TRACED TO 48" BELOW FINISHED GRADE . 15. TYPICAL OFFSET OF INTERIOR DOORS IS 4", UNLESS AT END OF CORRIDOR (WHERE THEY ARE CENTERED),OR UNO. 16. ALL WINDOW AND DOOR DIMENSIONS ARE TO CENTERLINE OF UNIT, UNO. 17. PER IBC CHAPTER 17, SPECIAL INSPECTIONS AND TESTS ARE REQUIRED. THESE SHALL BE PERFORMED BY A 3RD PARTY INSPECTOR APPROVED BY THE TOWN OF VAIL. INSPECTIONS AND TESTS INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING; STEEL CONSTRUCTION, CONCRETE CONSTRUCTION, MASONRY CONSTRUCTION, SOILS, DRIVEN DEEP FOUNDATIONS/PILES, SEISMIC RESISTANCE, SPRAY APPLIED FIRE RESISTIVE MATERIALS. TOP OF FINISHED FLOOR 2 STORIES + BASEMENT TYPE OF OCCUPANCY: TYPE OF CONSTRUCTION: LEVELS: TYPE V-N R3 (SINGE FAMILY) PROJECT INFORMATION PROJECT DIRECTORY GRAGE AREA: GROSS GRFA: UPPER LEVEL: MAIN LEVEL: LIVING AREA BELOW GARAGE: LOWER LEVEL: DATUM ELEVATION OF 100'-0" DATUM REFERENCE INDEX OF DRAWINGS GENERAL NOTES EQUALS ACTUAL ELEVATION OF XXXX'-0" ABOVE SEA LEVEL PARKING: 2 SPACES FIRE SUPPRESSION SYSTEM: NO BUILDING LOT SIZE: 0.1576 ACRES (6,865 S.F.) PARCEL NUMBER: A LEGAL DESCRIPTION: LOT 20, BLOCK 7, VAIL VILLAGE FILING 1 CLASS OF WORK: REMODEL 1/2 DUPLEX SECONDARY SIDE SF1,250 1,348 SF 360 SF 790 SF 475 SF 4,223 SF GRFA CALCULATIONS A0.00 COVER/INDEX A1.00 SITE PLAN A1.01 LANDSCAPE PLAN A1.02 GRFA DATA A1.03 GRFA PLANS A2.01D LOWER LEVEL EXISTING/DEMO PLAN A2.02D MAIN LEVEL EXISTING/DEMO PLAN A2.03D UPPER LEVEL EXISTING/DEMO PLAN A2.04D ROOF DEMO PLAN A2.00 GARAGE EXIST./PROPOSED PLANS +ELEVS. A2.01 PROPOSED LOWER LEVEL PLAN A2.02 PROPOSED MAIN LEVEL PLAN A2.03 PROPOSED UPPER LEVEL PLAN A2.04 PROPOSED ROOF PLAN A3.01 EAST ELEVATIONS A3.02 SOUTH ELEVATIONS A3.03 WEST ELEVATIONS A3.04 NORTH ELEVATIONS A4.01 BUILDING SECTIONS A8.00 WINDOW SCHEDULE A8.01 DOOR SCHEDULE COPYRIGHT RESERVATION ALL DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY THE ARCHITECT (DOUGLAS MILLER DECHANT ARCHITECTS / SHEPHERD RESOURCES, INC./ AIA HERE IN AFTER , "SRI") FOR PROJECTS FOR WHICH THE ARCHITECT HAS BEEN RETAINED ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE FOR USE SOLELY WITH RESPECT TO THE SPECIFIC PROJECT, UNLESS OTHERWISE PROVIDED IN WRITING, THE ARCHITECT SHALL BE DEEMED THE SOLE AND EXCLUSIVE AUTHOR OF SUCH DOCUMENTS AND SHALL RETAIN, WITHOUT LIMITATION, ALL COMMON LAW, STATUTORY AND OTHER REVERSED RIGHTS, INCLUDING THE COPYRIGHT HEREOF. NO PERSON (INCLUDING, WITHOUT LIMITATION, ALL EMPLOYEES AND/OR INDEPENDENT CONTRACTORS OF THE ARCHITECT), WHETHER HAVING COME RIGHTLY INTO POSSESSION THERE OF OR OTHERWISE, SHALL EMPLOY THESE DOCUMENTS ON ANY OTHER PROJECT, NOR FOR ADDITIONS TO ANY PROJECT NOR FOR THE COMPLETION OF ANY PROJECT FOR WHICH THE ARCHITECT HAS BEEN RETAINED BY OTHERS, OR MAKE ANY OTHER USE THEREOF WHATSOEVER, UNLESS WITH THE PRIOR EXPRESS WRITTEN CONSENT OF THE ARCHITECT AND UPON APPROPRIATE COMPENSATION TO THE ARCHITECT IN AN AMOUNT AND KIND SATISFACTORY TO THE ARCHITECT AS AGREED TO BY THE ARCHITECT IN WRITING. THE ARCHITECT EXPRESSLY CLAIMS ALL PROPRIETARY RIGHTS IN ALL MATERIAL FOR WHICH ARE ISSUED IN CONFIDENCE FOR DESIGN AND/OR CONSTRUCTION PURPOSES OF ALL PROJECTS FOR WHICH THE ARCHITECT HAS BEEN RETAINED AS NOTED. THESE MATERIALS MAY NOT BE COPIED, MODIFIED, NOR EMPLOYED IN ANY WAY BY ANY PERSON (INCLUDING, WITHOUT LIMITATION, AN EMPLOYEE OR EMPLOYEES) WITHOUT THE SPECIFIC PRIOR WRITTEN CONSENT AND PERMISSION OF THE ARCHITECT. THE FOREGOING SHALL APPLY EQUALLY TO ALL CONCEPT DRAWINGS, RENDERINGS, SKETCHES, BIDS AND ALL OTHER WORK PRODUCT OF THE ARCHITECT EVEN IN THE EVENT THAT THE ARCHITECT IS NOT ULTIMATELY RETAINED FOR THE SPECIFIC PROJECT FOR WHICH SUCH MATERIALS WERE CREATED AND TO ALL OTHER WORKS AND WORK PRODUCT OF THE ARCHITECT. (C) 2018 SHEPHERD RESOURCES, INC. ALL RIGHTS RESERVED. ALL ISSUANCES SHALL BE DISTRIBUTED IN FULL, WHICH INCLUDES BUT IS NOT LIMITED TO, ALL OF THE SHEETS LISTED IN THE INDEX OF DRAWINGS ON THIS SHEET, THE DETAIL MANUAL, THE PROJECT MANUAL, ADDENDA AND ARCHITECTURAL SUPPLEMENTAL INSTRUCTIONS. PLEASE CONTACT THE GENERAL CONTRACTOR IF YOU HAVE NOT RECEIVED A COMPLETE SET OF DOCUMENTS. PROJECT NORTH PROJECT NORTH IS INDICATED WITH A DARK LINE. ACTUAL NORTH IS INDICATED WITH A COMPASS NEEDLE. REFER TO SITE PLAN OR SURVEY DOCUMENTS TO VERIFY ACTUAL NORTH. XX TOP OF PLYWOOD (P) OR CONCRETE (C) SYSTEM NOTE ARCHITECT SHEPHERD RESOURCES, INC/AIA DOUG DECHANT BEN MARION PO BOX 1624 EDWARDS, CO 81632 (PHONE) 970.949.3302 (FAX) 970.949.5121 STRUCTURAL ENGINEER KRM CONSULTANTS, INC PO BOX 4572 VAIL, CO 81658 (PHONE) 970.949.9391 (FAX) 970.949.1577 LANDSCAPE ARCHITECT CERES LANDSCAPE ARCHITECTS SCOTT SONES PO BOX 3124 EAGLE CO 81631 INTERIOR FIXED FINISHES CAROL MUSICK DESIGN CAROL MUSICK 720-309-6730 SOILS ENGINEER N/A GENERAL CONTRACTOR MASTIFF DEVELOPMENT RON AMASS PO BOX 2096 EDWARDS, CO 81632 (PHONE) 970.926.8726 ABBREVIATIONS PRHT PARTIAL HEIGHT PVMT PAVEMENT QT QUARRY TILE R RISER R & S ROD AND SHELF RAD RADIUS RD ROOF DRAIN REF REFERENCE REFRIG REFRIGERATOR REINF REINFORCED REQD REQUIRED RESL RESILIENT REV REVISION RFG ROOFING RM ROOM RO ROUGH OPENING R/S ROUGH SAWN SCHED SCHEDULE SECT SECTION SF SQUARE FEET SHT SHEET SHTG SHEATHING SHWR SHOWER SIM SIMILAR SIPS STRUCTURAL INSULATED PANEL SPEC SPECIFICATION (S) SPRING SPRING POINT SQ SQUARE SST STAINLESS STEEL STC SOUND TRANSMISSION CLASS STD STANDARD STL STEEL STN STONE STRG STORAGE STRUCT or S STRUCTURAL SUSP SUSPENDED SYM SYMMETRICAL T TREAD TB TOWEL BAR TBD TO BE DETERMINED TC TRASH COMPACTOR TEL TELEPHONE THK THICK TMB TIMBER TJI ENGINEERED -BEAM TLT TOILET TMPR TEMPERED GLASS TPTN TOILET PARTITION TV TELEVISION THRU THROUGH T O TOP OF (MATERIAL) TRAP TRAPEZOID (WINDOW) TRTD TREATED TYP TYPICAL T & G TONGUE AND GROOVE UNCOND UNHEATED / UNCONDITIONED SPACE UND UNDER UNF UNFINISHED UNO UNLESS NOTED OTHERWISE UR URINAL UTIL UTILITY(IES) VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD W WIDTH, WIDE W/ WITH W/O WITHOUT WC WATER CLOSET WD WOOD WDW WINDOW WP WATERPROOFING WS WEATHERSTRIPPING WSCT WAINSCOT WT WEIGHT WWF WELDED WIRE FABRIC FRZR FREEZER FT FOOT / FEET FTG FOOTING FURR FURRING FUT FUTURE GA GAUGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GL GLASS, GLAZING GLAM GLUE LAMINATED BEAM GR GRADE GWB GYPSUM WALL BOARD GYP GYPSUM / GYPCRETE HB HOSE BIB HDR HEADER HDRL HANDRAIL HDWD HARDWOOD HDWR HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT HVAC HEATING/VENTING/AIR IB INSTALLED BY (WHOM) ID INSIDE DIAMETER IN INCH INCL INCLUDE (D), (ING) INFO INFORMATION INSUL INSULATION INT INTERIOR JAN JANITOR CLOSET JT JOINT KIT or K KITCHEN KP KICKPLATE L LENGTH LAM LAMINATE(D) LAV LAVATORY LDG LANDING LT LIGHT LV LOUVER LVL LAMINATED VENEER LUMBER MATL MATERIAL MAX MAXIMUM MC MEDICINE CABINET MECH MECHANICAL MFR MANUFACTURE (ER) MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MTL METAL N/A NOT APPLICABLE NIC NOT IN CONTRACT NOM NOMINAL NTS NOT TO SCALE OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OFC OFFICE OH OVERHEAD OPG OPENING OPP OPPOSITE OSB ORIENTED STRAND BOARD OV OVER PAN PANEL(ING) PARTN PARTITION PKT POCKET PL PLATE PLAS PLASTER PLMB PLUMBING PLYWD PLYWOOD PR PAIR PT POINT PTD PAINT(ED) (A) ACTIVE ABV ABOVE ACOUS ACOUSTICAL ADD ADDENDUM ADDL ADDITIONAL ADJ ADJACENT AFF ABOVE FINISHED FLOOR AFG ABOVE FINISH GRADE ALT ALTERNATE ALUM ALUMINUM AP ACCESS PANEL APPROX APPROXIMATE A or ARCH ARCHITECT (URAL) A/V AUDIO-VISUAL BATT BATT INSULATION BD BOARD BIT BITUMINOUS BLDG BUILDING BLK BLOCK(ING) BM BEAM B O BOTTOM OF (MATERIAL) BR BEER BRG BEARING BSMT BASEMENT BYO BY OTHERS CJ CONTROL JOINT CL CLOSET C/L or CENTERLINE CLK CAULK CLG CEILING CLR CLEAR (ANCE) CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONN CONNECTION CONT CONTINUOUS CORR CORRIDOR CPT CARPET CSMT CASEMENT CT CERAMIC TILE CUST CUSTOM DBL DOUBLE DEMO DEMOLISH, DEMOLITION DF DRINKING FOUNTAIN DIA or Ø DIAMETER DIM DIMENSION DN DOWN DOCS DOCUMENTS DS DOWNSPOUT DR DOOR DTL or D DETAIL DW DUMBWAITER DWG DRAWING EA EACH EJ EXPANSION JOINT ELEC ELECTRIC (AL) ELEV ELEVATION ENG ENGINEER(ING) EPB ELECTRICAL PANEL BOARD EQ EQUAL EQUIP EQUIPMENT EXG EXISTING EXT EXTERIOR FA FIRE ALARM FD FLOOR DRAIN FE FIRE EXTINGUISHER FF FINISHED FLOOR FIN FINISH FIXT FIXTURE FLR FLOOR (ING) F O FACE OF (MATERIAL) FNDN FOUNDATION FP FIREPLACE FRMG FRAMING BUTTERWORTH RESIDENCE 285 FOREST ROAD, VAIL COLORADO PROJECT DESCRIPTION: REMODEL OF SECONDARY HALF OF RESIDENTIAL DUPLEX. REPLACE A GABLE DORMER WITH NEW SHED DORMER. REPLACE AND ADD NEW WINDOWS AND DOORS. * REFER TO SHEETS A1.02 AND A1.03 FOR FULL GRFA CALCULATIONS AND SITE COVERAGE INFORMATION. PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION COVER SHEET A0.00 DATE ISSUE 3-28-18 SRI REVIEW 4-2-18 OWNER REVIEW 4-9-18 DRB - Change to Approved Plans 4-24-18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM SCALE: SITE PLAN1 1" = 10'-0" A1.00 NOTE: REQUIRED USE OF RIGHT OF WAY FOR STAGING, PARKING, ETC. REQUIRES A PUBLIC WAY PERMIT APPLICATION, CONTACT THE PUBLIC WORKS DEPARTMENT, LEONARD SANDOVAL AT 970.479.2198 PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION SITE PLAN A1.00 DATE ISSUE 3.28.18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM LIVING TERRACE BUILDING AREA BELOW HEATED STONE FINISH FOOTPRINT OF BUILDING BELOW EXISTING COVERED ENTRY SETBACK LINEPROPERTY LINESECONDAR Y UNIT PRI MARY UNI T SLOPE PER PL AN EXISTING DRAIN NEW DRAIN UP 2 STORY GARAGE DENOTES NEW EVERGREEN TREE DENOTES NEW DECIDUOUS TREE DENOTES NEW 5 GALLON SHRUBS DENOTES GROUND COVER DENOTES NEW 5 GALLON SHRUBS SCALE: LANDSCAPE PLAN1 1" = 10'-0"A1.01 LANDSCAPE AREA REQUIREMENT: LOT AREA .5019 ACRES = 21,863 SQ.FT. HARDSCAPE TOTAL PROPOSED = 3,358 SQ. FT. LANDSCAPE AREA PROPOSED SOFTSCAPE = 13,500 SQ.FT. HARDSCAPE (20% MAX) = 2,624 SQ.FT. TOTAL SOFTSCAPE AND HARDSCAPE = 16,124 SQ. FT. LANDSCAPE REQUIRED 60% MINIMUM (21,863x60%) = 13,118 SQ. FT. NEW DRYSTACK STONE VENEER DN SLOPE BBQ PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION LANDSCAPE PLAN A1.01 DATE ISSUE 3.28.18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Change t Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM WALL TOTAL WALL AREA UNEXPOSED AREA 1 211 SF 211 SF 2 44 SF 44 SF 3 55 SF 55 SF 4 28 SF 28 SF 5 84 SF 59 SF 6 75 SF 0 SF 7 82 SF 0 SF 8 101 SF 8 SF 9 33 SF 5 SF 10 277 SF 125 SF TOTAL 990 SF 535 SF SECONDARY UNIT BASEMENT CALCULATIONS WALL TOTAL WALL AREA UNEXPOSED AREA 1 71 SF 60 SF 2 75 SF 48 SF 3 62 SF 34 SF 4 159 SF 92 SF 5 162 SF 32 SF 6 136 SF 0 SF 7 259 SF 0 SF 8 108 SF 0 SF 9 24 SF 0 SF 10 284 SF 84 SF 11 196 SF 196 SF 12 212 SF 111 SF 13 64 SF 0 SF 14 76 SF 0 SF 15 111 SF 0 SF 16 272 SF 143 SF TOTAL 2,271 SF 800 SF PRIMARY UNIT BASEMENT CALCULATIONS TOTAL 3,261 SF 1,335 SF BASEMENT EXCLUSION % = 41% SCALE: SITE COVERAGE4 1/8" = 1'-0"A2.00 PRIMARY GARAGE 624 SF COVERED ENTRY 103 SF COVERED ENTRY 97 SF SECONDARY GARAGE SECONDARY UNIT 1,505 SF 475 SQ. FT. PRIMARY RESIDENCE GRFA CALCULATIONS: FLOOR AREA CALCULATIONS: LOWER LEVEL 1,179 SQ. FT. LIVING AREA BELOW GARAGE 266 SQ. FT. MAIN LEVEL 1,590 SQ. FT. GARAGE 624 SQ. FT. UPPER LEVEL 722 SQ. FT. GROSS GRFA 4,381 SQ. FT. GARAGE CREDIT (UP TO 600 SQ. FT.) (600) SQ. FT. BASEMENT CREDIT (41% x 1,179 SF) (483) SQ. FT. NET PRIMARY TOTAL GRFA 3,298 SQ. FT. PRIMARY TOTAL ALLOWABLE 4,435 SQ. FT. SECONDARY RESIDENCE GRFA CALCULATIONS: FLOOR AREA CALCULATIONS: LOWER LEVEL 1,250 SQ. FT. MAIN LEVEL 1,348 SQ. FT. LIVING AREA BELOW GARAGE 360 SQ. FT. UPPER LEVEL 790 SQ. FT. GARAGE AREA 475 SQ. FT. GROSS GRFA 4,223 SQ. FT. GARAGE CREDIT (UP TO 600 SQ. FT.) (475) SQ. FT. BASEMENT CREDIT (41% x 1,250 SF) (510) SQ. FT. NET SECONDARY TOTAL GRFA 3,238 SQ. FT. SECONDARY TOTAL ALLOWABLE 2,957 SQ. FT. SITE COVERAGE PRIMARY TOTAL SITE COVERAGE 2,317 SQ. FT. SECONDARY TOTAL SITE COVERAGE 2,077 SQ. FT. TOTAL SITE COVERAGE 4,394 SQ. FT. TOTAL SITE COVERAGE ALLOWED 4,373 SQ. FT. PRIMARY UNIT 1,590 SF PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION GRFA 1 A1.02 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM SCALE: SECONDARY LOWER LEVEL GRFA 1 1/8" = 1'-0"A2.00 BEDROOMONE 009 BEDROOMTWO 007 BEDROOMTHREE 002 FAMILYROOM 001 BATHONE 008 MECHROOM 006 BATHTWO 005 BATHTHREE 004 CLOSETTHREE 003 TERRACEW/D 1250 SF SECONDARY UNIT 1 2 3 4 5 7 6 8 10 9 PRIMARY RESIDENCE AREAS RE: TO GRFA PLANS PREPARED BY K.H. WEBB ARCHITECTS P.C.6'-334" 12'-1114"3'-1134" 10"33'-014"1245 SF 3'-1" 30'-2" 8'-5" 3'-1" SECONDARY UNIT 10'-814"37'-0"15'-734" 3'-11" 7'-11" 6'-7"8'-1" 2'-2" 1'-1" 7"14'-9" 4'-11" 8'-7" 6'-412" 7'-0" AFF 7'-0" AFF 7'-7 1/2" AFF 7'-0" AFF 7'-7 1/2" AFF 7'-8" AFF 6'-6" AFF 7'-0"6'-6"6' -6"7'-0" 6'-6" 7'-8"6'-6"7'-8"7'-7 12" 7'-0" 266 SQ. FT. BELOW GRADE 266 SQ. FT. WALL AREA 28 SQ. FT. BELOW GRADE 28 SQ. FT. WALL AREA 52 SQ. FT. BELOW GRADE 199 SQ. FT. WALL AREA 44 SQ. FT. BELOW GRADE 44 SQ. FT. WALL AREA 7 SQ. FT. BELOW GRADE 176 SQ. FT. WALL AREA 119 SQ. FT. BELOW GRADE 277 SQ. FT. WALL AREA 7'-2" AFF DININGROOM 101 LAUNDRY 107 BEDROOM/STUDY 104 STUDYBATH 105 LIVINGROOM 103 EXTERIORENTRY 100 KITCHEN 102 MUD ROOM 106 FOYER 108 SCALE: SECONDARY MAIN LEVEL GRFA2 1/8" = 1'-0"A2.00 1,348 SF SECONDARY UNIT PRIMARY RESIDENCE AREAS RE: TO GRFA PLANS PREPARED BY K.H. WEBB ARCHITECTS P.C. SCALE: SECONDARY UPPER LEVEL GRFA3 1/8" = 1'-0"A2.00 STUDY 205 MASTERBEDROOM 201 BALCONY 204 WICCLOSET 203 MASTERBATH 202 ATTIC 206 790 SF SECONDARY UNIT PRIMARY RESIDENCE AREAS RE: TO GRFA PLANS PREPARED BY K.H. WEBB ARCHITECTS P.C. BATH LIVING CRAWLSPACE STUDY SCALE: SECONDARY GARAGE GRFA5 1/8" = 1'-0"A2.00 360 SF GARAGE LIVING PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION GRFA 2 A1.03 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM W.S.BOILER 1 UP 12Tx13R 11'-712" 512" 5'-312"RELOCATE ELECTRICAL PANEL IN NEW WALL EXISTING LOW VOLTAGE PANEL BEDROOM ONE 009 BEDROOM TWO 007 BEDROOM THREE 002 FAMILY ROOM 001 BATH ONE 008 MECH ROOM 006 BATH TWO 005 BATH THREE 004 2'-112" 512" NEW FURRING WALL FOR PLUMBING NEW INFILL WALL BELOW GRADE WITH CMU RE: STRUCTURAL 3'-1112" 512"NEW BATHROOM 312"MODIFY EXISTING BEARING WALL FOR 6'-8" AFF HEIGHT DOOR RE: STRUCTURAL NEW STEAM SHOWER 5'-0" NEW WET BAR DOOR REFRAME 312" DEMO EXISTING LOWER LEVEL HEATING REGISTERS, INSTALL NEW INFLOOR GENERAL NOTES: 1. CONTRACTOR TO VERIFY ALL EXISTING SEPARATION WALL LOCATIONS, WALL/FLOOR/ROOF SYSTEMS, AND MECHANICAL/ELECTRICAL SERVICE LOCATIONS AND ROUTING. 2. SMOKE DETECTORS TO BE INTERCONNECTED PER IBC CODE -HARDWIRE 3. CARBON MONOXIDE DETECTORS TO BE INSTALLED PER IBC 4. EXISTING FIRE ALARM SYSTEMS TO REMAIN. REQUIRED MODIFICATIONS TO BE ENGINEERED BY BUILDING SUB-CONTRACTORS AND APPROVED BY FIRE DEPARTMENT PRIOR TO INSTALLATION 5. DO NOT SCALE DRAWINGS, IF DIMENSIONS ARE IN CONFLICT OR DO NOT APPEAR ON THE DRAWINGS, NOTIFY ARCHITECT. 6. ALL PLAN DIMENSIONS LOCATING PARTITIONS ARE TO FACE OF STUD OR BLOCK WALL FACE, U.N.O. 7. FINISH DIMENSIONS ARE TO THE FINISH FACE AND NOTES "FIN" OR "CLR". 8. CONTRACTOR TO REVIEW NEW ELECTRICAL PANEL, OUTLET, AND SWITCH LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN AND DRYWALL INSTALLATION. 9. REFER TO ELECTRICAL, LIGHTING AND LOW VOLTAGE DRAWINGS FOR COORDINATION. 10. ALL INTERIOR WALL TYPES ARE WP1 U.N.O. 11. IN-FLOOR RADIANT HEAT TO REPLACE EXISTING BASEBOARD HEATERS. 12. COORDINATE BLOCKING FOR BATH HARDWARE WITH INTERIOR ELEVATIONS AND CONTRACTOR. NEW BUILT-IN UNDER STAIR SCALE: PROPOSED LOWER PLAN1 1/4" = 1'-0"A2.01 BOILER 2 3'-034"10'-1014"512"2 A4.01 BOOK SHELVESW/ DOORS ANDDRAWERS BELOWNEW FREE STANDING HOT TUB ACOUSTICALLY FORTIFY WALL WITH ADDITIONAL LAYER OF 5 8" QUIET ROCK ON BEDROOM SIDE 3'-814" 2'-8" 512" 6'-3" NEW POCKET DOOR BENCH 3'-9"312 " 312"3'-812" 2'-112" 312"2'-2"312"4'-812"2 A3.01 2 A3.03 2 A3.04 UP CLOSETTHREE 003 BUILT-IN DESK14'-3" V.I.F.PRIMARY UNIT PRIMARY UNIT GARAGE LIVING 3'-0"2'-6" 2'-6"2'-6" 2'-6" 2'-0" 2'-0" 2'-0" 2'-6"2 A4.02 2 A4.01 TERRACE FIREPLACEREPLACE GAS FIREPLACE WITH NEW LOGSET AND FINISHES. FLUSH HEARTH WITH NEW FLOORING. WINDOW TO REMAIN WINDOW TO REMAIN WINDOW TO REMAIN WINDOW TO REMAIN WINDOW TO REMAIN WINDOW TO REMAIN DOOR TO REMAIN NEW BOILER SIDEWALL TERMINATION PER MANUF. REQ. REMOVE SHAFT AND CHIMNEY ABOVE. EXTEND DECK SIX FEET TO THE EAST, NEW STONE AND CAP WINDOW TO REMAIN PARTITION LEGEND: NEW WALL CONSTRUCTION EXISTING WALL CONSTRUCTION NEW STONE VENEER NEW STONE VENEER AT SITE WALLS NEW STONE VENEER ON REBUILT WALLS AND STAIRSREPLACE STONE VENEER PLUMB AN WIRE FOR FUTURE W/D W/D NEW DRYER VENT MIN. 3'-0" FROM WINDOW DECK ABOVE TO REMAIN EGRESS EGRESS EGRESS REPLACE, REPAIR AND EXTEND FLAGSTONE AND SNOWMELT AT PATIO NEW FLAT FURRING PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION PROPOSED LOWER LEVEL PLAN A2.01 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM PARTITION LEGEND: EXISTING WALL CONSTRUCTION DEMO EXISTING SCALE: DEMO LOWER PLAN1 1/4" = 1'-0" A2.01D HEATER HEATER TUBHEATERHEATERHEATER HEATERHEATERHEATER UP 12Tx13R WASHER DRYER ELECTRICAL PANEL BEDROOM ONE BEDROOM TWO BEDROOM THREE FAMILY ROOM MECH ROOM LAUNDRY ROOM BATHROOM TWO LIVING CLOSET BATH ONE TERRACE DEMOLITION NOTES: 1. CONTRACTOR TO COORDINATE ALL WORK WITH THE TOWN OF VAIL 2. REMOVE ALL EXISTING FURNITURE PRIOR TO STARTING DEMOLITION 3. PROCEED WITH CAUTION IN DEMOLISHING ANY EXISTING WALLS - REMOVE DRYWALL AND ANY OTHER FINISHES PRIOR TO REMOVING FRAMING. NOTIFY ARCHITECT AND ENGINEERS AS SOON AS WALLS, CEILINGS, AND FLOOR STRUCTURE HAVE BEEN EXPOSED FOR REVIEW OF EXISTING CONDITIONS. 4. CONTRACTOR TO NOTIFY ARCHITECT IF MECH, PLUMBING OR ELECTRICAL COMPONENTS ARE EXPOSED SO COMPONENTS CAN BE PROPERLY RE-ENGINEERED OR RE-ROUTED AS NECESSARY. 5. REMOVE ALL FLOOR FINISHES ON THIS LEVEL. 6. RECYCLE ALL APPLIANCES AND FIXTURES 7. REMOVE ALL DECORATIVE EXTERIOR WALL SCONCES. PREP FOR NEW FIXTURES W.S. BOILER 1 BOILER 2 PRIMARY UNIT PRIMARY UNIT GARAGE LIVING REMOVE ALL EXISTING HEATING ELEMENTS ON THIS LEVEL REMOVE EXISTING DOORS AND WALLS, PREP FOR NEW WALL REMOVE EXISTING PLUMBING FIXTURES, PREP FOR NEW PLUMBING FIXTURES PER PLAN REMOVE ALL EXISTING HEATING ELEMENTS ON THIS LEVEL REMOVE ALL EXISTING HEATING ELEMENTS ON THIS LEVEL REMOVE EXISTING FRAMING, PREP FOR CMU WALL REMOVE EXISTING PLUMBING FIXTURES, CABINETS, DOORS, WALLS, AND HEATING ELEMENTS, PREP FOR NEW BATHROOM DEMO END OF WALL, EXTEND PATIO, BUILD NEW WALL SIX FEET TO EAST DEMO STONE VENEER AND REPLACE WITH NEW STONE DEMO STONE VENEER AND REPLACE WITH NEW STONE PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION DEMO PLAN LOWER LEVEL A2.01D DATE ISSUE 3.28.18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM PRIMARY UNIT PRIMARY GARAGE 7'-2" AFF DINING ROOM 101 LAUNDRY 107 BEDROOM/STUDY 104 STUDY BATH 105 2 A4.01 SCALE: PROPOSED MAIN LEVEL PLAN1 1/4" = 1'-0"A2.02BALCONY LINE ABOVE 2 A4.02 LIVING ROOM 103 EXTERIOR ENTRY 100 SEE A2.02a FOR GARAGE LIVING AREA PLANS BUILDING LINE BELOW RIDGE BEAM ABOVE 2 A3.02 2 A3.01 2 A3.03 2 A3.04 UP GENERAL NOTES: 1. CONTRACTOR TO VERIFY ALL EXISTING SEPARATION WALL LOCATIONS, WALL/FLOOR/ROOF SYSTEMS, AND MECHANICAL/ELECTRICAL SERVICE LOCATIONS AND ROUTING. 2. SMOKE DETECTORS TO BE INTERCONNECTED PER IBC CODE -HARDWIRE 3. CARBON MONOXIDE DETECTORS TO BE INSTALLED PER IBC 4. EXISTING FIRE ALARM SYSTEMS TO REMAIN. REQUIRED MODIFICATIONS TO BE ENGINEERED BY BUILDING SUB-CONTRACTORS AND APPROVED BY FIRE DEPARTMENT PRIOR TO INSTALLATION 5. DO NOT SCALE DRAWINGS, IF DIMENSIONS ARE IN CONFLICT OR DO NOT APPEAR ON THE DRAWINGS, NOTIFY ARCHITECT. 6. ALL PLAN DIMENSIONS LOCATING PARTITIONS ARE TO FACE OF STUD OR BLOCK WALL FACE, U.N.O. 7. FINISH DIMENSIONS ARE TO THE FINISH FACE AND NOTES "FIN" OR "CLR". 8. CONTRACTOR TO REVIEW NEW ELECTRICAL PANEL, OUTLET, AND SWITCH LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN AND DRYWALL INSTALLATION. 9. REFER TO ELECTRICAL, LIGHTING AND LOW VOLTAGE DRAWINGS FOR COORDINATION. 10. ALL INTERIOR WALL TYPES ARE WP1 U.N.O. 11. IN-FLOOR RADIANT HEAT TO REPLACE EXISTING BASEBOARD HEATERS. 12. COORDINATE BLOCKING FOR BATH HARDWARE WITH INTERIOR ELEVATIONS AND CONTRACTOR. EXISTING DECK DRAIN KITCHEN TO REMAIN PRIMARY UNIT PRIMARY UNIT GARAGE 2'-1012"3'-2" 4'-10"2'-6"4'-10"2'-4"1'-11" 1'-11" 1'-10" 1'-11" 1'-11" 9" 2 A4.02 ELEVATION +07'-10 14" POSITIVE EXISTING SLOPE +07'-10 14" ELEVATION +07'-10 1 2" NEW BI-FOLD DOORS IN EXISTING LOWER OPENINGS LOWER SILL TO FLOOR KITCHEN 102 D.W.RANGEREF.MUD ROOM 106 PANTRY W EXISTING DECK DRAIN NEW DOOR AND WINDOWS NEW LAUNDRY ROOM, ADD SINK AND WASHER / DRYER FLUE TO THE ROOF NEW WINDOWS, ALIGN WITH WINDOWS ABOVE AND CENTER ON DORMER. NEW MUD ROOM, BUILT IN BENCH, HOOKS, SHELF AND CUBBIES INFILL OLD WINDOW LOCATIONS NEW BI-FOLD DOORS IN EXISTING LOWER OPENINGS LOWER SILL TO FLOOR WALKWAY ABOVE DN BEAM ABOVE BEAM ABOVE WINDOWS REMAIN DECK AND RAIL TO REMAIN WINDOWS REMAIN WINDOWS REMAIN WINDOW REMAIN WINDOWS REMAIN WINDOW REMAIN WINDOWS REMAIN EXISTING FIREPLACE TO REMAIN, REFER TO INTERIOR ELEVATIONS FOR NEW INTERIOR FINISHES FOYER 108 LOW CEILING 5'-0" A.F.F. 2'-1012" 2'-1012" 2'-1012" NEW WINDOW 2'-1012"6'-5" REMOVE CENTER POST D PARTITION LEGEND: NEW WALL CONSTRUCTION EXISTING WALL CONSTRUCTION NEW STONE VENEER NEW SINK AND COUNTER NEW STONE VENEER REPLACE FLAGSTONE PATIO AND SNOWMELT NEW WINDOW 1'-6" 6" 3'-0" 6"1'-6"2'-1012" REPLACE EXISTING STAIR AND STONE VENEER WALL REPLACE STONE VENEER REPLACE STONE VENEER REPLACE STONE VENEER BEAM ABOVE 7'-0" 5'-0" EGRESS RAILING TO REMAIN NEW EPA WOOD BURNING INSERT PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION PROPOSED MAIN LEVEL PLAN A2.02 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Change to Approved Plans 4.24.18 OWNER REVEW DRB APPROVED 4/30/2018 12:00:00 AM 360 SF LIVING SPACE BELOW GARAGE 22'-6" 22'-6"8'-5"6'-1" 6'-118"8'-10"10'-8"14'-6"19'-6" 6'-2" BATH LIVING CRAWL SPACE STUDY 7'-4" AFF 22'-6"22'-6" 9'-6" 10'-0"14'-6"19'-6" 6'-2" LIVING G01 NEW BATH G02CRAWL SPACE G03 7'-4" AFF WASHER/DRYERSTACK3'-112"2'-7" 3'-018" 312" 6'-218" T.V. CABINETSLEEPERSOFAKITCHENETTE36"x36" TABLE 6'-1" 5'-5" 3'-0"6'-0" 8'-0" 1'-3" 2'-0" 60" EGRESS DOOR 6'-8" STONE VENEER TO REMAIN WOOD SIDING TO REMAIN 1'-758" 5'-0" 5'-6" 4:12 SCALE: PROPOSED GARAGE ROOF8 1/4" = 1'-0"A2.00 TWO CAR GARAGE G04 BUILDING OUTLINE BELOW NEW COPPER GUTTERS AND DRAIN LEADERS - TYP. EXISTING SHAKE TO REMAIN SCALE: PROPOSED LIVING SPACE BELOW GARAGE2 1/4" = 1'-0"A2.00 SCALE: EXISTING LIVING SPACE BELOW GARAGE1 1/4" = 1'-0"A2.00SCALE: EXISTING GARAGE NORTH ELEVATION 4 1/4" = 1'-0" A2.00 SCALE: EXISTING GARAGE3 1/4" = 1'-0"A2.00 SCALE: EXISTING GARAGE ROOF 6 1/4" = 1'-0"A2.00 4:12 4:124:12 BUILDING OUTLINE BELOW CEDAR SHAKE FINISH NEW DOUBLE BAR SNOW FENCE ANCHORED TO SEAMS - TYP. SCALE: PROPOSED GARAGE EAST ELEVATION7 1/4" = 1'-0"A2.00 2'-4" 4'-4"REPLACE CLAD WOOD WINDOWS TO MATCH EXISTING NEW COPPER GUTTERS AND DRAIN LEADERS - TYP. EXISTING SHAKE TO REMAIN NEW DOUBLE BAR SNOW FENCE ANCHORED TO SEAMS - TYP.6'-0"50 51 NEW CLAD WOOD WINDOWS TO MATCH EXISTING REPLACE ENTRY DOOR SCALE: PROPOSED GARAGE NORTH ELEVATION5 1/4" = 1'-0"A2.00 4:124:12 2'-4" 4'-4"50 51 SCALE: DOOR SCHEDULE 10 NTS A2.00 SCALE: WINDOW SCHEDULE9 NTSA2.00 PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION GARAGE EXISTING AND PROPOSED A2.00 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM SCALE: MAIN DEMO PLAN1 1/4" = 1'-0"A2.02D DINING ROOM 101 ENTRY 100 LIVING ROOM 103 KITCHEN 102 BEDROOM/STUDY 104 RANGEREF. STUDY BATH 105 HEATER HEATERHEATERSEE A2.02a FOR GARAGE LIVING AREA PLANS BUILDING LINE BELOW DEMOLITION NOTES: 1. CONTRACTOR TO COORDINATE ALL WORK WITH THE TOWN OF VAIL 2. REMOVE ALL EXISTING FURNITURE PRIOR TO STARTING DEMOLITION 3. PROCEED WITH CAUTION IN DEMOLISHING ANY EXISTING WALLS - REMOVE DRYWALL AND ANY OTHER FINISHES PRIOR TO REMOVING FRAMING. NOTIFY ARCHITECT AND ENGINEERS AS SOON AS WALLS, CEILINGS, AND FLOOR STRUCTURE HAVE BEEN EXPOSED FOR REVIEW OF EXISTING CONDITIONS. 4. CONTRACTOR TO NOTIFY ARCHITECT IF MECH, PLUMBING OR ELECTRICAL COMPONENTS ARE EXPOSED SO COMPONENTS CAN BE PROPERLY RE-ENGINEERED OR RE-ROUTED AS NECESSARY. 5. REMOVE ALL FLOOR FINISHES THROUGHOUT 6. RECYCLE ALL APPLIANCES AND FIXTURES 7. REMOVE ALL DECORATIVE EXTERIOR WALL SCONCES. PREP FOR NEW FIXTURES PRIMARY UNIT PRIMARY UNIT GARAGE REMOVE EXISTING WINDOWS AND WALLS, PREP FOR NEW WINDOWS REPLACE EXISTING WINDOWS AND DOORS REMOVE EXISTING LOWER WINDOWS, CENTER POST AND HEATING ELEMENT, PREP FOR NEW DOORS IN EXISTING OPENINGS. D.W. NEW INTERIOR FINISHES ON EXISTING FIREPLACE. REMOVE SHAFT AND CHIMNEY ABOVE, FLL IN FLOOR AND CEILING FOR PANTRY DEMO EXISTING STAIRS AND REPLACE WITH CODE COMPLIANT STAIR AND RAIL. EXISTING BALCONY ABOVE TO REMAIN REMOVE EXISTING FLAGSTONE PATIO AND SNOWMELT, REPLACE WITH NEW FLAGSTONE AND SNOWMELT SYSTEM. NEW WINDOW REPLACE WINDOWS WITH BAD SEALS - MATCH EXISTING TYP. PARTITION LEGEND: EXISTING WALL CONSTRUCTION DEMO EXISTING PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION DEMO PLAN MAIN LEVEL A2.02D DATE ISSUE 3.28.18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM STUDY 205 MASTER BEDROOM 201 BALCONY 204 2 A4.02 2 A4.01 WIC CLOSET 203 3'-114" MASTER BATH 202 3'-2"4'-012" FIN. 2'-0"4'-0" FIN.TUB SCALE: PROPOSED UPPER PLAN1 1/4" = 1'-0" A2.03ATTIC 3'-6" HEIGHT MAX.7'-0"NEW HEATED TOWEL BAR FRAMELESS GLASS SHOWER ENCLOSURE 312"312" 512"312"312" 6'-8"10'-134" 312"312" 7'-114" 4'-0"3'-2" 9" 2'-1012" 5'-9" 4'-10"CENTER NEW WINDOW GROUP ON NEW SHED DORMER 4" 4'-10"2'-10" 8'-834" ATTIC 3'-6" HEIGHT MAX. 312" 2 A3.02 2 A3.03 2 A3.01 2 A3.04 GENERAL NOTES: 1. CONTRACTOR TO VERIFY ALL EXISTING SEPARATION WALL LOCATIONS, WALL/FLOOR/ROOF SYSTEMS, AND MECHANICAL/ELECTRICAL SERVICE LOCATIONS AND ROUTING. 2. SMOKE DETECTORS TO BE INTERCONNECTED PER IBC CODE -HARDWIRE 3. CARBON MONOXIDE DETECTORS TO BE INSTALLED PER IBC 4. EXISTING FIRE ALARM SYSTEMS TO REMAIN. REQUIRED MODIFICATIONS TO BE ENGINEERED BY BUILDING SUB-CONTRACTORS AND APPROVED BY FIRE DEPARTMENT PRIOR TO INSTALLATION 5. DO NOT SCALE DRAWINGS, IF DIMENSIONS ARE IN CONFLICT OR DO NOT APPEAR ON THE DRAWINGS, NOTIFY ARCHITECT. 6. ALL PLAN DIMENSIONS LOCATING PARTITIONS ARE TO FACE OF STUD OR BLOCK WALL FACE, U.N.O. 7. FINISH DIMENSIONS ARE TO THE FINISH FACE AND NOTES "FIN" OR "CLR". 8. CONTRACTOR TO REVIEW NEW ELECTRICAL PANEL, OUTLET, AND SWITCH LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN AND DRYWALL INSTALLATION. 9. REFER TO ELECTRICAL, LIGHTING AND LOW VOLTAGE DRAWINGS FOR COORDINATION. 10. ALL INTERIOR WALL TYPES ARE WP1 U.N.O. 11. BASEBOARD HEATERS TO REMAIN ON THIS LEVEL. 12. COORDINATE BLOCKING FOR BATH HARDWARE WITH INTERIOR ELEVATIONS AND CONTRACTOR. DN PRIMARY UNIT 2'-6"1'-10" 1'-10" 1'-11" 1'-11" 2'-4"2 A4.02 NEW PLUMBING TO BE COORDINATED WITH NEW AND EXISTING STRUCTURE NEW PLUMBING TO BE IN WALL, ROUTE IN WALL TO KITCHEN SOFFIT BELOW ATTIC 206 2'-1012" 4" 5'-0" HEIGHT MAX.2'-0" NEW WINDOW WINDOW TO REMAIN WINDOW TO REMAIN REPLACE WINDOW WINDOWS TO REMAIN WINDOWS TO REMAIN NEW WINDOWS WINDOW TO REMAIN NEW WINDOW NEW STONE VENEER EXIST. RIDGE BEAM EXIST. BEAM EXIST. BEAM EXIST. BEAM ROOF OVERHANGROOF OVERHANG NEW 30X30 SKYLIGHT LINEN WINDOW TO REMAIN 42" WALL PARTITION LEGEND: NEW WALL CONSTRUCTION EXISTING WALL CONSTRUCTION NEW STONE VENEER ATTIC ACCESS PANELATTIC ACCESS PANEL EXISTING RAIL AT REMAIN 5'-8"REPLACE WINDOW5'-8" 8" EGRESS PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION PROPOSED UPPER LEVEL PLAN A2.03 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Chage to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM SCALE: UPPER DEMO PLAN1 1/4" = 1'-0"A2.03D MASTER CLOSET 203 MASTER BATH 202 MASTER BEDROOM 201 BALCONY 204 HEATERHEATERHEATER HEATER HEATER DEMOLITION NOTES: 1. CONTRACTOR TO COORDINATE ALL WORK WITH THE TOWN OF VAIL 2. REMOVE ALL EXISTING FURNITURE PRIOR TO STARTING DEMOLITION 3. PROCEED WITH CAUTION IN DEMOLISHING ANY EXISTING WALLS - REMOVE DRYWALL AND ANY OTHER FINISHES PRIOR TO REMOVING FRAMING. NOTIFY ARCHITECT AND ENGINEERS AS SOON AS WALLS, CEILINGS, AND FLOOR STRUCTURE HAVE BEEN EXPOSED FOR REVIEW OF EXISTING CONDITIONS. 4. CONTRACTOR TO NOTIFY ARCHITECT IF MECH, PLUMBING OR ELECTRICAL COMPONENTS ARE EXPOSED SO COMPONENTS CAN BE PROPERLY RE-ENGINEERED OR RE-ROUTED AS NECESSARY. 5. REMOVE ALL FLOOR FINISHES THROUGHOUT 6. RECYCLE ALL APPLIANCES AND FIXTURES 7. REMOVE ALL DECORATIVE EXTERIOR WALL SCONCES. PREP FOR NEW FIXTURES REMOVE WALL SECTION AND PREP AREA FOR NEW WINDOW UNITS - TYP. DN PRIMARY UNIT REMOVE EXISTING WINDOWS, DORMER AND WALLS, PREP FOR NEW WALLS REMOVE EXISTING PLUMBING FIXTURES, CABINETS, DOORS, WALLS, AND HEATING ELEMENTS, PREP FOR NEW BATHROOM PREP FOR NEW WINDOW CEILING BEAM TO REMAIN CEILING BEAM TO REMAIN CEILING BEAM TO REMAIN CEILING BEAM TO REMAIN REMOVE WINDOW IN FILL FRAMING REMOVE WINDOW IN FILL FRAMING REMOVE WINDOW PREP FOR NEW WINDOW PARTITION LEGEND: EXISTING WALL CONSTRUCTION DEMO EXISTING PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION DEMO PLAN UPPER LEVEL A2.03D DATE ISSUE 3.28.18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM NEW VALLEY FLASHING TO BE TIED IN TO NEW ROOF WATERPROOF MEMBRANE 2 A3.02 2 A3.04 SCALE: PROPOSED ROOF PLAN1 1/4" = 1'-0"A2.04 2 A4.02 2 A4.01 BUILDING OUTLINE BELOW NEW STANDING SEAM METAL PANELS - DARK BRONZE COLOR NEW DOUBLE BAR SNOW FENCE ANCHORED TO SEAMS - TYP. NEW COPPER GUTTERS AND DRAIN LEADERS - TYP. NEW COPPER GUTTERS AND DRAIN LEADERS - TYP. EXISTING CHIMNEY TO REMAIN, ADD NEW STONE VENEER AND STONE CAP 4:12 EXISTINGNEW 1:12 PITCH AT SOUTH FACING SLOPE 2 A3.01 2 A3.03 PRIMARY UNIT 1:124:12 REPLACE WOOD SHAKES WITH NEW CLASS A STANDING SEAM METAL ROOFING - DARK BRONZE COLOR REPLACE WOOD SHAKES WITH NEW CLASS A STANDING SEAM METAL ROOFING - DARK BRONZE COLOR REPLACE WOOD SHAKES WITH NEW CLASS A STANDING SEAM METAL ROOFING - DARK BRONZE COLOR NEW SKYLIGHT DARK BRONZE STANDING SEAM METAL ROOF / ICE + WATER SHIELD , FLASHING AND SNOW FENCE PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION PROPOSED ROOF PLAN A2.04 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM SCALE: ROOF DEMO PLAN1 1/4" = 1'-0" A2.04D4:12REMOVE THIS AREA OF SOUTH FACING ROOF SLOPE AND PREPARE AREA FOR NEW 1:12 PITCH AND FINISH REMOVE ENTIRE DORMER REMOVE MECHANICAL CHIMNEY PRIMARY UNIT DEMOLITION NOTES: 1. CONTRACTOR TO COORDINATE ALL WORK WITH THE TOWN OF VAIL 2. REMOVE ALL EXISTING FURNITURE PRIOR TO STARTING DEMOLITION 3. PROCEED WITH CAUTION IN DEMOLISHING ANY EXISTING WALLS - REMOVE DRYWALL AND ANY OTHER FINISHES PRIOR TO REMOVING FRAMING. NOTIFY ARCHITECT AND ENGINEERS AS SOON AS WALLS, CEILINGS, AND FLOOR STRUCTURE HAVE BEEN EXPOSED FOR REVIEW OF EXISTING CONDITIONS. 4. CONTRACTOR TO NOTIFY ARCHITECT IF MECH, PLUMBING OR ELECTRICAL COMPONENTS ARE EXPOSED SO COMPONENTS CAN BE PROPERLY RE-ENGINEERED OR RE-ROUTED AS NECESSARY. 5. REMOVE ALL FLOOR FINISHES THROUGHOUT 6. RECYCLE ALL APPLIANCES AND FIXTURES 7. REMOVE ALL DECORATIVE EXTERIOR WALL SCONCES. PREP FOR NEW FIXTURES4:12 REMOVE EXISTING SHAKE SHINGLES FROM ROOF, REPLACE WITH 1 12" RIGID INSULATION, NEW ICE AND WATER SHIELD AND STANDING SEAM METAL ROOFING. REPAIR EXISTING ROOF SHEATHING AS NEEDED. REMOVE EXISTING SHAKE SHINGLES FROM ROOF, REPLACE WITH 1 12" RIGID INSULATION, NEW ICE AND WATER SHIELD AND STANDING SEAM METAL ROOFING. REPAIR EXISTING ROOF SHEATHING AS NEEDED. REMOVE EXISTING SHAKE SHINGLES FROM ROOF, REPLACE WITH 1 12" RIGID INSULATION, NEW ICE AND WATER SHIELD AND STANDING SEAM METAL ROOFING. REPAIR EXISTING ROOF SHEATHING AS NEEDED. REMOVE ROOF SECTION AND PREP AREA FOR NEW SKYLIGHT PARTITION LEGEND: EXISTING WALL CONSTRUCTION DEMO EXISTING PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION DEMO PLAN ROOF A2.04D DATE ISSUE 3.28.18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM SCALE: EXISTING EAST ELEVATION1 1/4" = 1'-0"A3.01 LOWER LEVEL FF EL: 100'-0" MAIN LEVEL FF EL: 107'-10 1/4"' UPPER LEVEL FF EL: 116'-0 1/4" 1 A4.02 LOWER LEVEL FF EL: 100'-0" MAIN LEVEL FF EL: 107'-10 1/4"' UPPER LEVEL FF EL: 116'-0 1/4" 1 A4.02 4 12 1 12 2 A4.03 SCALE: PROPOSED EAST ELEVATION1 1/4" = 1'-0"A3.01 NEW 1:12 SHED ROOF DORMER MATCH EXISTING SIDING, TRIM, FASCIA AND SOFFIT REPLACE LOWER WINDOWS WITH BI-FOLD DOORS NEW STUCCO WITH SIDING, MATCH EXISTING REPLACE STONE VENEER NEW STONE VENEER, REPLACE STUCCO REPLACE UPPER WINDOWS REPLACE DOOR AND WINDOWS NEW WINDOW PARTIAL VIEW NEW SKYLIGHT 1 1 1 2 2 2 3 3 4 6 7 GENERAL NOTES: 1) ALL WINDOWS AND EXTERIOR DOORS CLAD WOOD 2) ALL FLASHING TO BE METAL TO MATCH ROOF AND INSTALLED AT ALL LOCATIONS REQUIRED BY CODE. 3) DIMENSIONED WALL OPENINGS ARE NOMINAL. WINDOW REP. TO FIELD VERIFY ALL OPENINGS. 4) EXTEND FOUNDATION WATERPROOF MEMBRANE UP WALL 30" MINIMUM ABOVE GRADE 5) EXTERIOR LOUVERS/VENTS TO BE PAINTED TO MATCH ADJACENT FINISH 6) ALL VENT STACKS TO BE PAINTED TO MATCH ROOF COLOR 7) SAMPLES OF ALL MATERIALS AND FINISHES TO BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION 8) ALL EXPOSED STEEL TO BE SHOP PRIMED AND FIELD FINISH PAINTED 9) ALL EXPOSED GUTTER AND DOWNSPOUT METAL TO MATCH ROOF. DOWNSPOUTS TO BE HEAVY GAUGE PIPE - NO FLEX CONNECTORS 10) EXTEND ROOF WATERPROOFING UP ALL SIDE WALLS AND CHIMNEY FORMS A MINIMUM OF 24" 11) SEE ARCHITECTURAL SUPPLEMENTAL INFORMATION BOOK AND DETAILS FOR ADDITIONAL CORE/SHELL INFORMATION AND SPECIFICATIONS 7 1 3 4 2 5 HEM FIR TRIM WITH SEMI-TRANSPARENT FINISH 6 DECORATIVE CLOSE MESH METAL SHROUD STANDING SEAM METAL ROOF WITH FLAT PAN - MINIMUM 24 GAUGE - DARK BRONZE COLOR 1x T&G VERTICAL GRAIN HEM FIR SOFFIT DECKING WITH +/- 5" FACE EXPOSURE - SEMI-TRANSPARENT FINISH EXPOSED HEAVY TIMBER 1x T&G VERTICAL GRAIN HEM FIR SIDING WITH +/- 5" FACE EXPOSURE - SEMI-TRANSPARENT FINISH DRYSTACK REGIONAL STONE VENEER MATERIAL KEY: PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION EAST ELEVATION EXISTING AND PROPOSED A3.01 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM SCALE: EXISTING SOUTH ELEVATION1 1/4" = 1'-0"A3.02 1 A4.01 LOWER LEVEL FF EL: 100'-0" MAIN LEVEL FF EL: 107'-10 1/2"' UPPER LEVEL FF EL: 116'-0 1/2"7'-1012" 8'-2"1 A4.01 LOWER LEVEL FF EL: 100'-0" MAIN LEVEL FF EL: 107'-10 1/2"' UPPER LEVEL FF EL: 116'-0 1/2"7'-1012" 8'-2" SCALE: PROPOSED SOUTH ELEVATION2 1/4" = 1'-0"A3.026'-6"3'-6"5'-9" 4" 2'-1012" 4" 2'-1012" NEW WINDOW WINDOWS REMAIN NEW WINDOWS REPLACE WOOD SHAKES WITH SANDING SEAM METAL ROOFNG NEW DORMER WITH STANDING SEAM COVERING NEW WINDOW REPLACE WOOD SHAKES WITH SANDING SEAM METAL ROOFNG NEW STONE VENEER, REPLACE STUCCO 2'-1012"2'-1012" NEW SKYLIGHT 1 2 3 4 5 55 GENERAL NOTES: 1) ALL WINDOWS AND EXTERIOR DOORS CLAD WOOD 2) ALL FLASHING TO BE METAL TO MATCH ROOF AND INSTALLED AT ALL LOCATIONS REQUIRED BY CODE. 3) DIMENSIONED WALL OPENINGS ARE NOMINAL. WINDOW REP. TO FIELD VERIFY ALL OPENINGS. 4) EXTEND FOUNDATION WATERPROOF MEMBRANE UP WALL 30" MINIMUM ABOVE GRADE 5) EXTERIOR LOUVERS/VENTS TO BE PAINTED TO MATCH ADJACENT FINISH 6) ALL VENT STACKS TO BE PAINTED TO MATCH ROOF COLOR 7) SAMPLES OF ALL MATERIALS AND FINISHES TO BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION 8) ALL EXPOSED STEEL TO BE SHOP PRIMED AND FIELD FINISH PAINTED 9) ALL EXPOSED GUTTER AND DOWNSPOUT METAL TO MATCH ROOF. DOWNSPOUTS TO BE HEAVY GAUGE PIPE - NO FLEX CONNECTORS 10) EXTEND ROOF WATERPROOFING UP ALL SIDE WALLS AND CHIMNEY FORMS A MINIMUM OF 24" 11) SEE ARCHITECTURAL SUPPLEMENTAL INFORMATION BOOK AND DETAILS FOR ADDITIONAL CORE/SHELL INFORMATION AND SPECIFICATIONS 7 1 3 4 2 5 HEM FIR TRIM WITH SEMI-TRANSPARENT FINISH 6 DECORATIVE CLOSE MESH METAL SHROUD STANDING SEAM METAL ROOF WITH FLAT PAN - MINIMUM 24 GAUGE - DARK BRONZE COLOR 1x T&G VERTICAL GRAIN HEM FIR SOFFIT DECKING WITH +/- 5" FACE EXPOSURE - SEMI-TRANSPARENT FINISH EXPOSED HEAVY TIMBER 1x T&G VERTICAL GRAIN HEM FIR SIDING WITH +/- 5" FACE EXPOSURE - SEMI-TRANSPARENT FINISH DRYSTACK REGIONAL STONE VENEER MATERIAL KEY: PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION SOUTH ELEVATION EXISTING AND PROPOSED A3.02 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM SCALE: EXISTING WEST ELEVATION1 1/4" = 1'-0"A3.03 1 A4.02 LOWER LEVEL FF EL: 100'-0" MAIN LEVEL FF EL: 107'-10 1/2"' UPPER LEVEL FF EL: 116'-0 1/2" 1 A4.02 LOWER LEVEL FF EL: 100'-0" MAIN LEVEL FF EL: 107'-10 1/2"' UPPER LEVEL FF EL: 116'-0 1/2" 4 12 112 SCALE: PROPOSED WEST ELEVATION2 1/4" = 1'-0"A3.03 NEW MECHANICAL SIDE WALL VENT, LOCATION PER MANUF. REQUIREMENTS COORD. LOCATION WITH OWNER AND ARCHITECT. NEW WINDOW NEW WINDOW EXISTING ROOF CUT BACK, REPAIR AS NEEDED NEW DORMER, TIE INTO EXISTING ROOF; REFER TO STRUCTURAL DRAWINGS NEW PITCH BREAK EXISTING ROOF TO REMAIN NEW WINDOW NEW STONE VENEER, REPLACE STUCCO NEW SKYLIGHT DRIER VENT 7 1 4 6 BOILER VENT 2 3 GENERAL NOTES: 1) ALL WINDOWS AND EXTERIOR DOORS CLAD WOOD 2) ALL FLASHING TO BE METAL TO MATCH ROOF AND INSTALLED AT ALL LOCATIONS REQUIRED BY CODE. 3) DIMENSIONED WALL OPENINGS ARE NOMINAL. WINDOW REP. TO FIELD VERIFY ALL OPENINGS. 4) EXTEND FOUNDATION WATERPROOF MEMBRANE UP WALL 30" MINIMUM ABOVE GRADE 5) EXTERIOR LOUVERS/VENTS TO BE PAINTED TO MATCH ADJACENT FINISH 6) ALL VENT STACKS TO BE PAINTED TO MATCH ROOF COLOR 7) SAMPLES OF ALL MATERIALS AND FINISHES TO BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION 8) ALL EXPOSED STEEL TO BE SHOP PRIMED AND FIELD FINISH PAINTED 9) ALL EXPOSED GUTTER AND DOWNSPOUT METAL TO MATCH ROOF. DOWNSPOUTS TO BE HEAVY GAUGE PIPE - NO FLEX CONNECTORS 10) EXTEND ROOF WATERPROOFING UP ALL SIDE WALLS AND CHIMNEY FORMS A MINIMUM OF 24" 11) SEE ARCHITECTURAL SUPPLEMENTAL INFORMATION BOOK AND DETAILS FOR ADDITIONAL CORE/SHELL INFORMATION AND SPECIFICATIONS 7 1 3 4 2 5 HEM FIR TRIM WITH SEMI-TRANSPARENT FINISH 6 DECORATIVE CLOSE MESH METAL SHROUD STANDING SEAM METAL ROOF WITH FLAT PAN - MINIMUM 24 GAUGE - DARK BRONZE COLOR 1x T&G VERTICAL GRAIN HEM FIR SOFFIT DECKING WITH +/- 5" FACE EXPOSURE - SEMI-TRANSPARENT FINISH EXPOSED HEAVY TIMBER 1x T&G VERTICAL GRAIN HEM FIR SIDING WITH +/- 5" FACE EXPOSURE - SEMI-TRANSPARENT FINISH DRYSTACK REGIONAL STONE VENEER MATERIAL KEY: PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION WEST ELEVATION EXISTING AND PROPOSED A3.03 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM SCALE: EXISTING NORTH ELEVATION1 1/4" = 1'-0"A3.03 LOWER LEVEL FF EL: 100'-0" MAIN LEVEL FF EL: 107'-10 1/2"' UPPER LEVEL FF EL: 116'-0 1/2" SCALE: PROPOSED NORTH ELEVATION1 1/4" = 1'-0"A3.03 LOWER LEVEL FF EL: 100'-0" MAIN LEVEL FF EL: 107'-10 1/2"' UPPER LEVEL FF EL: 116'-0 1/2" 1 A4.03 REPLACE WOOD SHAKE ROOF WITH STANDING SEAM METAL ROOFING INFILL NICHE WITH NEW STONE VENEER NEW STONE VENEER 4 5 1 1 2 3 GENERAL NOTES: 1) ALL WINDOWS AND EXTERIOR DOORS CLAD WOOD 2) ALL FLASHING TO BE METAL TO MATCH ROOF AND INSTALLED AT ALL LOCATIONS REQUIRED BY CODE. 3) DIMENSIONED WALL OPENINGS ARE NOMINAL. WINDOW REP. TO FIELD VERIFY ALL OPENINGS. 4) EXTEND FOUNDATION WATERPROOF MEMBRANE UP WALL 30" MINIMUM ABOVE GRADE 5) EXTERIOR LOUVERS/VENTS TO BE PAINTED TO MATCH ADJACENT FINISH 6) ALL VENT STACKS TO BE PAINTED TO MATCH ROOF COLOR 7) SAMPLES OF ALL MATERIALS AND FINISHES TO BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION 8) ALL EXPOSED STEEL TO BE SHOP PRIMED AND FIELD FINISH PAINTED 9) ALL EXPOSED GUTTER AND DOWNSPOUT METAL TO MATCH ROOF. DOWNSPOUTS TO BE HEAVY GAUGE PIPE - NO FLEX CONNECTORS 10) EXTEND ROOF WATERPROOFING UP ALL SIDE WALLS AND CHIMNEY FORMS A MINIMUM OF 24" 11) SEE ARCHITECTURAL SUPPLEMENTAL INFORMATION BOOK AND DETAILS FOR ADDITIONAL CORE/SHELL INFORMATION AND SPECIFICATIONS 7 1 3 4 2 5 HEM FIR TRIM WITH SEMI-TRANSPARENT FINISH 6 DECORATIVE CLOSE MESH METAL SHROUD STANDING SEAM METAL ROOF WITH FLAT PAN - MINIMUM 24 GAUGE - DARK BRONZE COLOR 1x T&G VERTICAL GRAIN HEM FIR SOFFIT DECKING WITH +/- 5" FACE EXPOSURE - SEMI-TRANSPARENT FINISH EXPOSED HEAVY TIMBER 1x T&G VERTICAL GRAIN HEM FIR SIDING WITH +/- 5" FACE EXPOSURE - SEMI-TRANSPARENT FINISH DRYSTACK REGIONAL STONE VENEER MATERIAL KEY: PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION NORTH ELEVATION EXISTING AND PROPOSED A3.04 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.8 DRB - Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM 7'-8"13'-112"12'-212"9'-1"4'-914" 2'-8 12"6'-614"8'-112"SCALE: EXISTING CROSS SECTION1 1/4" = 1'-0"A4.01 1 A4.02 LOWER LEVEL FF EL: 100'-0" MAIN LEVEL FF EL: 107'-10 1/2"' UPPER LEVEL FF EL: 116'-0 1/2" EXISTING ROOF STRUCTURE 7'-8" 13'-112"12'-212"9'-1"6'-9"8'-112"LOWER LEVEL FF EL: 100'-0" MAIN LEVEL FF EL: 107'-10 1/2"' UPPER LEVEL FF EL: 116'-0 1/2"7'-2" +/-SCALE: PROPOSED CROSS SECTION2 1/4" = 1'-0" A4.01 NEW ATTIC STORAGE SPACE 5'-0"NEW STUDY 6'-6" +/-MASTER CLOSET MASTER BATH MASTER BEDROOM PREFAB TRUSS STRUCTURE AT ATTIC AREA AREA OF NEW SHED DORMER NEW SKYLIGHT 3'-0"1 12 EGRESS WINDOW EGRESS WINDOW EGRESS WINDOW EGRESS WINDOW GENERAL ASSEMBLY NOTES: NEW SLOPING ROOF CEILING ASSEMBLY ▪ STANDING SEAM METAL ROOF OVER ▪ ROOF WATERPROOF MEMBRANE OVER ▪ STRUCTURAL PLYWOOD SHEATHING OVER (RE: STRUCTURAL) OVER ▪ 11.5" SPRAY FOAM INSULATION AT BOTTOM SIDE OF SHEATHING_R-71.3 MIN. ▪ STRUCTURAL ROOF JOISTS (RE: STRUCTURAL) ▪ 2 MIL SMART MEMBRANE VAPOR RETARDER ▪ 1x6 T&G DECKING OR DRYWALL PER REFLECTED CEILING PLANS NEW FLAT ROOF/TERRACE CEILING ASSEMBLY ▪ STONE PAVER OVER ▪ LIGHTWEIGHT CONCRETE SETTING BED WITH RADIANT HEAT LOOPS OVER, ▪ DRAINAGE BOARD OVER ▪ PROTECTION LAYER OVER ▪ HOT-FLUID APPLIED MONOLITHIC WATERPROOF MEMBRANE (AMERICAN HYDROTECH 6125 FR) ON ▪ ADHERED COVER BOARD OVER - MECHANICALLY-ATTACHED RIGID BOARD INSULATION 3" MINIMUM AT DRAINS OVER HABITABLE SPACE_R-18.0 MIN. ▪ TAPERED RIGID INSULATION ▪ STRUCTURAL STEEL DECKING WITH CONCRETE TOPPING (RE: STRUCTURAL) ▪ 6" SPRAY FOAM INSULATION AT BOTTOM SIDE OF STEEL DECKING_R-37.2 MIN. ▪ STRUCTURAL ROOF JOISTS UNLESS NOTED OTHERWISE (RE: STRUCTURAL) ▪ 2 MIL SMART MEMBRANE VAPOR RETARDER ▪ 1x6 T&G DECKING OR DRYWALL PER REFLECTED CEILING PLANS STEEL ROOF SUPPORTS AND ALL STEEL STRUCTURE AT EXTERIOR TO INTERIOR TRANSITION ▪ ENCAPSULATE AT INTERIOR SIDE WITH 1 1/2" MIN. SPRAY FOAM INSULATION TO MIN. 4'-0" INSIDE FROM EXTERIOR FACE OF EXTERIOR WALLS; MAKE CONTINUOUS WITH SPRAY FOAM INSULATION IN ROOF AND WALLS FLOOR CEILING ASSEMBLY ▪ SEE PLANS FOR FINISH ▪ 58" "WARM BOARD" WITH RADIANT HEAT LOOPS OVER ▪ PLYWOOD DECKING (RE: STRUCTURAL) OR EXISTING DECKING OVER ▪ STRUCTURAL MEMBERS (RE: STRUCTURAL) OR EXISTING DECKING OVER ▪ BLOWN-IN BLANKET INSULATION AT JOIST CAVITIES_R-38 MIN. OR EXPOSED PER RCP ▪ SEE RCP'S FOR CEILING FINISH SLAB ON GRADE ASSEMBLY (INTERIOR FLOOR SLABS ONLY) ▪ SEE PLANS FOR FINISH ▪ STRUCTURAL CONCRETE SLAB WITH ▪ HYDRONIC HEAT TUBING OVER ▪ 15 MIL POLYETHYLENE VAPOR DIFFUSION RETARDER OVER ▪ RIGID INSULATION_R-10 MIN. OVER ▪ 6" GRAVEL BALLAST FRAMED EXTERIOR WALLS ▪ SEE ELEVATIONS FOR FINISH ▪ HOME SLICKER RAINSCREEN OVER ▪ AIR BARRIER/WEATHER-RESISTIVE BARRIER OVER ▪ 12" PLYWOOD SHEATHING (PER STRUCTURE) OR EXISTING SHEATHING ON ▪ 2X6 WOOD STUDS OR EXISTING STUDS ▪ 3" SPRAY FOAM INSULATION AT INSIDE FACE OF SHEATHING_R-18.6 MIN. ▪ 2.5" BLOWN-IN BLANKET INSULATION _R-10 MIN. (R-28.6 TOTAL) FOUNDATION WALLS ▪ DRAIN AND DRY BOARD BY MAR-FLEX_R-10 OVER ▪ HOT-FLUID APPLIED WATERPROOFING OVER ▪ CONCRETE FOUNDATION WALL (RE: STRUCTURAL) ▪ 2x FURRING AND INSULATION PER PLAN ON INTERIOR_R-9 MINIMUM FRAMED INTERIOR PARTITION WALLS ▪ BLOWN-IN CELLULOSE INSULATION PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION BUILDING SECTIONS A4.01 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 DRB - Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 20 21 42 43 44 45 SCALE: WINDOW SCHEDULE1 NTS A8.00 PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION WINDOW SCHEDULE A8.00 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM SCALE: DOOR SCHEDULE1 NTS A8.01 PROJECT: S H E P H E R D R E S O U R C E S I N C / A I A VAIL / BEAVER CREEK EDWARDS C O L O R A D O 8 1 6 32 9 7 0 9 4 9 3 3 0 2 W W W . S R I A R C H I T E C T . C O M 1720 FOREST ROAD 285 March 23, 2018 VAIL, DESIGN DEVELOPMENT COLORADO LOT 20, BLOCK 7 VAIL VILLAGE FILING 1 FOR NOT CONSTRUCTION DOOR SCHEDULE A8.01 DATE ISSUE 3-28-18 SRI REVIEW 4.2.18 OWNER REVIEW 4.9.18 Change to Approved Plans 4.24.18 OWNER REVIEW DRB APPROVED 4/30/2018 12:00:00 AM