HomeMy WebLinkAboutB18-0144_Approved Plans_1527198902.pdf05/24/18 05/24/18 Edwards Residence Remodel 2670 Bald Mountain Rd. Permit Application No. B18-0144 Review Response Narrative Cover Sheet • The client has opted to reduce the clear height at the crawl space to 4’-10” (T/Concrete +94’-2”) and the No. 2 door accessing the crawl space has been eliminated thus confirming with the planning code provision and excluding the proposed crawl space from the GRFA calculations. • Building Code Notes have been added including conformance to THE 2015 IECC. All Plan Sheets: • A graphic scale has been added to all plan sheets and dimensions added where missing (Lower Level Plan). Please note that remaining plan sheets are divided into “Layout” Plan Sheets (A2.2 & A2.4) and separate “Finish” Plans. The later are reserved for finishes and various call-outs and do not show dimensions by design. All requisite dimensions are located on the “layout” Plans. A2.2: • A note has been added regarding conformance of to 2015 RBC Chapter 3 BUILDING PLANNING; 302.5 and 302.6. • The notes on the Door Schedule for Door Tag 4 also require conformance to the 2015 RBC Chapter 3 BUILDING PLANNING; 302.5. A2.6: • The requirement that the matching asphalt shingles provide a Class A roof rating has been noted on this and the elevations sheets as requested. A2.4: • All notations regarding smoke and carbon monoxide detectors have been added to the Lighting & Power Layout sheets as well as to the general notes on the Cover Sheet. • All notations regarding windows including matters of Egress, Safety Glazing, U Value Minimums and Fall Protection can be found on the Window Schedule sheet A6.0 and variously noted on Sheets A3.0 & A3.1. A2.7: • The requirement that the matching asphalt shingles provide a Class A roof rating has been noted on this and the elevations sheets as requested. 05/24/18 A3.0: • The Class A roof rating has been noted. • Dimensions have been added to windows to identify sill heights. • A note has been added regarding conformance of to 2015 RBC Chapter 3 BUILDING PLANNING; 308 Glazing; 310 Emergency Escape and Rescue Openings; 312 Window Fall Protection; and Chapter 4 Building Thermal Envelope of the 2015 IECC for conformance with glazing U value. • Door 2 accessing the crawl space has been eliminated to assure that the crawl space is not counted as GRFA. A3.1: • The railing indicated on the drawings represents an existing railing that is remaining. In spite of this, I have added a notation that stipulates that the raining conform to current height and member spacing criteria per the 2015 RBC. • The Class A roof rating has been noted. • The requires insulation values per 2015 RBC have been indicated on the Cover Sheet. • A note has been added regarding conformance of to 2015 RBC Chapter 3 BUILDING PLANNING; 308 Glazing; 310 Emergency Escape and Rescue Openings; 312 Window Fall Protection; and Chapter 4 Building Thermal Envelope of the 2015 IECC for conformance with glazing U value. A6.0: • A note has been added regarding conformance of to 2015 RBC Chapter 3 BUILDING PLANNING; 308 Glazing; 310 Emergency Escape and Rescue Openings; 312 Window Fall Protection; and Chapter 4 Building Thermal Envelope of the 2015 IECC for conformance with glazing U value. S2: • As this is an existing residence and we were unable to access an existing sols investigation, we are opting to develop our drawings with assumed criteria and are directing the General Contractor (See Sheet S1 – “Foundation Design” – Note f.) to retain a geotechnical engineer to verify soils conditions and types during excavation. The note continues on to require these confirmations with the Structural Engineer prior to proceeding with the construction of foundations. 05/24/18 05/24/18 05/24/18 05/24/18 GRFA 426.9 SF 05/24/18 GRFA 1130 SF Garage 825 SF 05/24/18 05/24/18 GRFA 1972 SF 05/24/18 05/24/18 05/24/18 05/24/18 05/24/18 05/24/18 05/24/18 Geologically Sensitive Area Moderate Hazard Debris Flow 05/24/18 Geologically Sensitive Area Moderate Hazard Debris Flow 05/24/18 Geologically Sensitive Area Moderate Hazard Debris Flow 05/24/18 05/24/18 05/24/18 05/24/18 04/13/2018 05/24/18 04/13/2018 Soils Report to be submitted prior to footings inspection to confirm 2000psf min 05/24/18 04/13/2018 05/24/18 04/13/2018 05/24/18 04/13/2018 05/24/18 04/13/2018 05/24/18