HomeMy WebLinkAboutDRB18-0149_approved plans_1525288085.pdfBASEMENT SOUTH
8195' - 0"
FIRST FLOOR
SOUTH
8203' - 11"
SECOND FLOOR
SOUTH
8212' - 10"
THIRD FLOOR
SOUTH
8221' - 9"
FOURTH FLOOR
SOUTH
8230' - 8"
TYP.17
TYP.1
TYP.1
TYP.1
TYP.5
TYP.2
TYP.2
NEW UTILITY ENCLOSURE
TYP.8
DOES NOT MATCH.
REPLACE AND NOTIFY
OWNERS.
NEW TRASH ENCLOSURE
INFILL W/ WOOD TRIM TO BELLY BAND INFILL W/ WOOD TRIM TO BELLY BAND
* * **
REPAINT UNIT #513 WINDOW
AND DOOR SASH TYP
11
A506
Sim
9
A505
Sim
11
A506
Sim
6
A506
Sim
2
A506
Sim
3
A506
Sim
7
A505
Sim
6
A506
Sim
10
A506
Sim
7
A505
Sim7
A505
Sim7
A505
Sim11
A506
Sim
6
A506
Sim
7
A505
Sim
5
A506
Sim
3
A506
Sim
11
A506
Sim
*ADD 2 X 6 TRIM @ 11/A506 TYP
DOWNSPOUTS TO BE
REINSTALLED
NEW TUBE STEEL COLUMN
DRIVE THRU
A906
1
SAVE EXISTING WINDOW
1
1
1
CEDAR PLANK - TO BE REMOVED
EXISTING MATERIALS
SPLIT-FACE CMU - TO REMAIN AND
BE COVERED WITH NEW SIDING
ASPHALT
SHINGLES TO
REMAIN
CEMENTIOUS LAP SIDING - 7"
EXPOSURE (MOUNTAIN SAGE - HARDIE
PLANK)¹
PROPOSED MATERIALS
CEMENTIOUS STUCCO
(CROISSANT - SHERWIN WILLIAMS)
¹
STONE¹
¹TO MATCH 100/200 BUILDING
ASPHALT SHINGLES (MATCH
EXISTING)
1. ALL EXISTING WINDOWS TO BE REPLACED, EXCEPT WHERE NOTED;
CONTRACTOR TO PROVIDE DOOR AND WINDOW SCHEDULE BASED ON
MINIMUM REDUCTION OF EXISTING OPENING DIMENSIONS AND TO VERIFY
EMERGENCY EGRESS REQUIREMENTS FOR NEW WINDOWS
2. MATERIAL COLORS TO MATCH EXISTING ON 100/200 BUILDING (STONE TO
MATCH 300/400 BUILDING)
3. EXISTING CEDAR SHAKE SIDING TO BE REMOVED
4. EXISTING SPLIT-FACE CMU TO REMAIN AND BE COVERED BY NEW MATERIALS
AS PROPOSED AND REPAIRED AS NECESSARY
5. STUCCO TO RECEIVE CONTROL JOINTS PER MFR'S RECOMMENDATION AND
PER PATTERNS INDICATED ON ELEVATIONS
6. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING GUTTERS AND
DOWNSPOUTS AND INSTALL NEW GUTTERS AND DOWNSPOUTS WHERE
NOTED AND BE PLUMB AND HORIZONTAL. RE A101
7. ALL EXISTING HEAT TAPE TO BE REPLACED; NEW HEAT TAPED INSTALLED AT
NEW GUTTERS AND DOWNSPOUTS
8. CONTRACTOR TO REMOVE AND REPLACE EXPOSED UTILITIES AS NEEDED TO
COMPLETE THE WORK IN A NEAT AND WORKMANLIKE MANNER
9. CONTRACTOR TO REMOVE AND REPLACE EXTERIOR LIGHT FIXTURES AND ADD
LIGHT AND OUTLET TO EACH UNIT DECK
10. CONTRACTOR TO CLEAN AND REPAINT ALL DECK STRUCTURE TO REMAIN
11. ALL DECKS TO BE RESURFACED WITH REDWOOD DECKING WITH NEW
FLASHING TO BE INSTALLED AT SURROUNDING WALLS AND EDGE. 1 X 6 AT
UNIT DECKS (EXCEPT AT UNIT 501). 2 X 6 AT COMMON WALKWAYS.
12. ALL EXISTING DRYER VENT TERMINATIONS TO BE REPLACED WITH SEIHO
MODEL SFB-P OR SFB AS APPROPRIATE; ALL OTHER VENT TERMINATIONS TO
BE REPLACED WITH SIMILAR SIMILAR TO MATCH 100/200 BUILDING
13. REPAIR AND PATCH EXISTING GYPSUM BOARD SHEATHING WHERE
NECESSARY WTH PLYWOOD
14. REPLACE EXTERIOR CONDUIT AS NECESSARY AND CONCEAL AS CONDITIONS
ALLOW.
15. REPLACE COMMON WALKWAYS, STAIRS AND DECK STRUCTURE PER STRUCT
ENGINEER.
16. REMOVE AND REPLACE EXISTING PAINT ON TIMBER COLUMNS AT COMMON
WALKWAYS
17. ALL EXISTING CONCRETE WALKWAYS TO REMAIN EXCEPT WHERE NOTED
18.
19.
20. ALL MOUNTING ON HARDIE PLANK SIDING TO USE STURDIMOUNT MOUNTING
BLOCKS
21. REFER TO JAMES HARDE WEBSITE FOR REQUIRED INSTALLATION GUIDELINES
(WWW.JAMESHARDIEPROS.COM) REVIEW THE INSTALLATION INSTRUCTIONS
FOR THESE CRITICAL DETAILS(A) CLEARANCE TO SMF (B) CLEARANCE TO
GRADE, CONC., AND ROOF (C) PRIMING OF SIDES, INCLUDING FIELD CUT
EDGES (D) SEALANT AT LOCATIONS AS REQ'D BY MFGR. (E) MFGR.
RECOMENDED DETAILS AT LAP
GENERAL NOTES
1
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
04/16/18
A203
SOUTH
ELEVATIONBREAKAWAY WEST 500EXTERIOR IMPROVEMENTS1634__963 LIONS RIDGE LOOP, VAIL, CO 8167509/05/17
3/16" = 1'-0"A203
2 SOUTH ELEVATION - PROPOSED
# DESCRIPTION
1 FIBER CEMENT LAP SIDING, 7" EXPOSURE - COLOR: HARDIE FACTORY-APPLIED MOUNTAIN SAGE
JH50-30 BOTH FACES - ON TYVEK BUILDING WRAP
2 CEMENTITOUS STUCCO - COLOR: SHERWIN WILLIAMS SW7716 CROISSANT - ON TYVEK BUILDING
WRAP
3 BELLY BAND - 2X10 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 VAN BUREN
BROWN
5 WINDOW TRIM - 2X6 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 HASBROUCK
BROWN - OVER VYCOR WINDOW STRIP
8 DECK RAILING - POWDER COATED METAL RAILING TO MATCH 100/200 BLDG - COLOR: BLACK
17 STONE - TO MATCH EXISTING 100/200 BUILDING
18 STUCCO JOINTS TO MATCH 100/200 BUILDING
KEYNOTE LEGEND
1
DRB
APPROVED
5/2/2018 12:00:00
AM
BASEMENT SOUTH
8195' - 0"
FIRST FLOOR
SOUTH
8203' - 11"
SECOND FLOOR
SOUTH
8212' - 10"
THIRD FLOOR
SOUTH
8221' - 9"
FOURTH FLOOR
SOUTH
8230' - 8"
GARAGE / UNDER POOL
TYP.1
TYP.2
TYP.1
TYP.2
7' SECURITY POOL PROTECT FENCE
TRIM
SAVE / REUSE
TRASH ROOM
EGRESS
*
*
REPAINT UNIT #513 WINDOW
AND DOOR SASH TYP
OWNER TO VERIFY
2
A506
Sim
11
A506
Sim
6
A506
Sim
11
A506
Sim
11
A506
Sim
6
A506
Sim
6
A506
Sim
11
A506
Sim
11
A506
Sim
5
A506
Sim
6
A506
Sim
6
A506
Sim
7
A505
Sim 7
A505
Sim
7
A505
Sim
9
A505
Sim
5
A507
Sim
*BEYOND
*ADD 2 X 6 TRIM @ 11/A506 TYP
DRIVE THRU
BELLY BAND
METAL ROOF W/ SNOW FENCING
REPAINT DOORS AND FRAME
2 X 6 BETWEEN SIDING AND STUCCO
1
1
1
CEDAR PLANK - TO BE REMOVED
EXISTING MATERIALS
SPLIT-FACE CMU - TO REMAIN AND
BE COVERED WITH NEW SIDING
ASPHALT
SHINGLES TO
REMAIN
CEMENTIOUS LAP SIDING - 7"
EXPOSURE (MOUNTAIN SAGE - HARDIE
PLANK)¹
PROPOSED MATERIALS
CEMENTIOUS STUCCO
(CROISSANT - SHERWIN WILLIAMS)
¹
STONE¹
¹TO MATCH 100/200 BUILDING
ASPHALT SHINGLES (MATCH
EXISTING)
1. ALL EXISTING WINDOWS TO BE REPLACED, EXCEPT WHERE NOTED;
CONTRACTOR TO PROVIDE DOOR AND WINDOW SCHEDULE BASED ON
MINIMUM REDUCTION OF EXISTING OPENING DIMENSIONS AND TO VERIFY
EMERGENCY EGRESS REQUIREMENTS FOR NEW WINDOWS
2. MATERIAL COLORS TO MATCH EXISTING ON 100/200 BUILDING (STONE TO
MATCH 300/400 BUILDING)
3. EXISTING CEDAR SHAKE SIDING TO BE REMOVED
4. EXISTING SPLIT-FACE CMU TO REMAIN AND BE COVERED BY NEW MATERIALS
AS PROPOSED AND REPAIRED AS NECESSARY
5. STUCCO TO RECEIVE CONTROL JOINTS PER MFR'S RECOMMENDATION AND
PER PATTERNS INDICATED ON ELEVATIONS
6. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING GUTTERS AND
DOWNSPOUTS AND INSTALL NEW GUTTERS AND DOWNSPOUTS WHERE
NOTED AND BE PLUMB AND HORIZONTAL. RE A101
7. ALL EXISTING HEAT TAPE TO BE REPLACED; NEW HEAT TAPED INSTALLED AT
NEW GUTTERS AND DOWNSPOUTS
8. CONTRACTOR TO REMOVE AND REPLACE EXPOSED UTILITIES AS NEEDED TO
COMPLETE THE WORK IN A NEAT AND WORKMANLIKE MANNER
9. CONTRACTOR TO REMOVE AND REPLACE EXTERIOR LIGHT FIXTURES AND ADD
LIGHT AND OUTLET TO EACH UNIT DECK
10. CONTRACTOR TO CLEAN AND REPAINT ALL DECK STRUCTURE TO REMAIN
11. ALL DECKS TO BE RESURFACED WITH REDWOOD DECKING WITH NEW
FLASHING TO BE INSTALLED AT SURROUNDING WALLS AND EDGE. 1 X 6 AT
UNIT DECKS (EXCEPT AT UNIT 501). 2 X 6 AT COMMON WALKWAYS.
12. ALL EXISTING DRYER VENT TERMINATIONS TO BE REPLACED WITH SEIHO
MODEL SFB-P OR SFB AS APPROPRIATE; ALL OTHER VENT TERMINATIONS TO
BE REPLACED WITH SIMILAR SIMILAR TO MATCH 100/200 BUILDING
13. REPAIR AND PATCH EXISTING GYPSUM BOARD SHEATHING WHERE
NECESSARY WTH PLYWOOD
14. REPLACE EXTERIOR CONDUIT AS NECESSARY AND CONCEAL AS CONDITIONS
ALLOW.
15. REPLACE COMMON WALKWAYS, STAIRS AND DECK STRUCTURE PER STRUCT
ENGINEER.
16. REMOVE AND REPLACE EXISTING PAINT ON TIMBER COLUMNS AT COMMON
WALKWAYS
17. ALL EXISTING CONCRETE WALKWAYS TO REMAIN EXCEPT WHERE NOTED
18.
19.
20. ALL MOUNTING ON HARDIE PLANK SIDING TO USE STURDIMOUNT MOUNTING
BLOCKS
21. REFER TO JAMES HARDE WEBSITE FOR REQUIRED INSTALLATION GUIDELINES
(WWW.JAMESHARDIEPROS.COM) REVIEW THE INSTALLATION INSTRUCTIONS
FOR THESE CRITICAL DETAILS(A) CLEARANCE TO SMF (B) CLEARANCE TO
GRADE, CONC., AND ROOF (C) PRIMING OF SIDES, INCLUDING FIELD CUT
EDGES (D) SEALANT AT LOCATIONS AS REQ'D BY MFGR. (E) MFGR.
RECOMENDED DETAILS AT LAP
GENERAL NOTES
1
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
04/16/18
A204
NORTH
ELEVATIONBREAKAWAY WEST 500EXTERIOR IMPROVEMENTS1634__963 LIONS RIDGE LOOP, VAIL, CO 8167509/05/17
3/16" = 1'-0" A204
3 NORTH ELEVATION - PROPOSED
# DESCRIPTION
1 FIBER CEMENT LAP SIDING, 7" EXPOSURE - COLOR: HARDIE FACTORY-APPLIED MOUNTAIN SAGE
JH50-30 BOTH FACES - ON TYVEK BUILDING WRAP
2 CEMENTITOUS STUCCO - COLOR: SHERWIN WILLIAMS SW7716 CROISSANT - ON TYVEK BUILDING
WRAP
3 BELLY BAND - 2X10 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 VAN BUREN
BROWN
5 WINDOW TRIM - 2X6 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 HASBROUCK
BROWN - OVER VYCOR WINDOW STRIP
8 DECK RAILING - POWDER COATED METAL RAILING TO MATCH 100/200 BLDG - COLOR: BLACK
17 STONE - TO MATCH EXISTING 100/200 BUILDING
18 STUCCO JOINTS TO MATCH 100/200 BUILDING
KEYNOTE LEGEND
DRB
APPROVED
5/2/2018 12:00:00
AM
FIRST FLOOR
SOUTH
8203' - 11"
SECOND FLOOR
SOUTH
8212' - 10"
THIRD FLOOR
SOUTH
8221' - 9"
FOURTH FLOOR
SOUTH
8230' - 8"
FIRST LEVEL
NORTH
8202' - 9"
SECOND LEVEL
NORTH
8213' - 2 1/4"
THIRD FLOOR
NORTH
8222' - 1 1/4"
2
A505
NEW RAILING WHERE
NONE CURRENTLY
EXISTS
TYP.2
TYP.1
TYP.17
NEW TRASH
ENCLOSURE TO
REPLACE EXIST.
GATE STYLE
DOOR
MOCK UP WINDOW / SAVE
INFILL W/ WOOD TRIM TO BELLY BAND
* *
11
A506
Sim
11
A506
Sim
11
A506
Sim
2
A506
Sim
1
A506
Sim
2
A506
Sim
A507
6 Sim
A505
11 Sim
6
A506
Sim
11
A506
Sim
7
A505
Sim
1
1. ALL EXISTING WINDOWS TO BE REPLACED, EXCEPT WHERE NOTED;
CONTRACTOR TO PROVIDE DOOR AND WINDOW SCHEDULE BASED ON
MINIMUM REDUCTION OF EXISTING OPENING DIMENSIONS AND TO VERIFY
EMERGENCY EGRESS REQUIREMENTS FOR NEW WINDOWS
2. MATERIAL COLORS TO MATCH EXISTING ON 100/200 BUILDING (STONE TO
MATCH 300/400 BUILDING)
3. EXISTING CEDAR SHAKE SIDING TO BE REMOVED
4. EXISTING SPLIT-FACE CMU TO REMAIN AND BE COVERED BY NEW MATERIALS
AS PROPOSED AND REPAIRED AS NECESSARY
5. STUCCO TO RECEIVE CONTROL JOINTS PER MFR'S RECOMMENDATION AND
PER PATTERNS INDICATED ON ELEVATIONS
6. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING GUTTERS AND
DOWNSPOUTS AND INSTALL NEW GUTTERS AND DOWNSPOUTS WHERE
NOTED AND BE PLUMB AND HORIZONTAL. RE A101
7. ALL EXISTING HEAT TAPE TO BE REPLACED; NEW HEAT TAPED INSTALLED AT
NEW GUTTERS AND DOWNSPOUTS
8. CONTRACTOR TO REMOVE AND REPLACE EXPOSED UTILITIES AS NEEDED TO
COMPLETE THE WORK IN A NEAT AND WORKMANLIKE MANNER
9. CONTRACTOR TO REMOVE AND REPLACE EXTERIOR LIGHT FIXTURES AND ADD
LIGHT AND OUTLET TO EACH UNIT DECK
10. CONTRACTOR TO CLEAN AND REPAINT ALL DECK STRUCTURE TO REMAIN
11. ALL DECKS TO BE RESURFACED WITH REDWOOD DECKING WITH NEW
FLASHING TO BE INSTALLED AT SURROUNDING WALLS AND EDGE. 1 X 6 AT
UNIT DECKS (EXCEPT AT UNIT 501). 2 X 6 AT COMMON WALKWAYS.
12. ALL EXISTING DRYER VENT TERMINATIONS TO BE REPLACED WITH SEIHO
MODEL SFB-P OR SFB AS APPROPRIATE; ALL OTHER VENT TERMINATIONS TO
BE REPLACED WITH SIMILAR SIMILAR TO MATCH 100/200 BUILDING
13. REPAIR AND PATCH EXISTING GYPSUM BOARD SHEATHING WHERE
NECESSARY WTH PLYWOOD
14. REPLACE EXTERIOR CONDUIT AS NECESSARY AND CONCEAL AS CONDITIONS
ALLOW.
15. REPLACE COMMON WALKWAYS, STAIRS AND DECK STRUCTURE PER STRUCT
ENGINEER.
16. REMOVE AND REPLACE EXISTING PAINT ON TIMBER COLUMNS AT COMMON
WALKWAYS
17. ALL EXISTING CONCRETE WALKWAYS TO REMAIN EXCEPT WHERE NOTED
18.
19.
20. ALL MOUNTING ON HARDIE PLANK SIDING TO USE STURDIMOUNT MOUNTING
BLOCKS
21. REFER TO JAMES HARDE WEBSITE FOR REQUIRED INSTALLATION GUIDELINES
(WWW.JAMESHARDIEPROS.COM) REVIEW THE INSTALLATION INSTRUCTIONS
FOR THESE CRITICAL DETAILS(A) CLEARANCE TO SMF (B) CLEARANCE TO
GRADE, CONC., AND ROOF (C) PRIMING OF SIDES, INCLUDING FIELD CUT
EDGES (D) SEALANT AT LOCATIONS AS REQ'D BY MFGR. (E) MFGR.
RECOMENDED DETAILS AT LAP
GENERAL NOTES
1
CEDAR PLANK - TO BE REMOVED
EXISTING MATERIALS
SPLIT-FACE CMU - TO REMAIN AND
BE COVERED WITH NEW SIDING
ASPHALT
SHINGLES TO
REMAIN
CEMENTIOUS LAP SIDING - 7"
EXPOSURE (MOUNTAIN SAGE - HARDIE
PLANK)¹
PROPOSED MATERIALS
CEMENTIOUS STUCCO
(CROISSANT - SHERWIN WILLIAMS)
¹
STONE¹
¹TO MATCH 100/200 BUILDING
ASPHALT SHINGLES (MATCH
EXISTING)
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
04/16/18
A205
WEST
ELEVATIONBREAKAWAY WEST 500EXTERIOR IMPROVEMENTS1634__963 LIONS RIDGE LOOP, VAIL, CO 8167509/05/17
3/16" = 1'-0"A205
2 WEST ELEVATION - PROPOSED
# DESCRIPTION
1 FIBER CEMENT LAP SIDING, 7" EXPOSURE - COLOR: HARDIE FACTORY-APPLIED MOUNTAIN SAGE
JH50-30 BOTH FACES - ON TYVEK BUILDING WRAP
2 CEMENTITOUS STUCCO - COLOR: SHERWIN WILLIAMS SW7716 CROISSANT - ON TYVEK BUILDING
WRAP
3 BELLY BAND - 2X10 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 VAN BUREN
BROWN
5 WINDOW TRIM - 2X6 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 HASBROUCK
BROWN - OVER VYCOR WINDOW STRIP
8 DECK RAILING - POWDER COATED METAL RAILING TO MATCH 100/200 BLDG - COLOR: BLACK
17 STONE - TO MATCH EXISTING 100/200 BUILDING
18 STUCCO JOINTS TO MATCH 100/200 BUILDING
KEYNOTE LEGEND
DRB
APPROVED
5/2/2018 12:00:00
AM
BASEMENT SOUTH
8195' - 0"
FIRST FLOOR
SOUTH
8203' - 11"
SECOND FLOOR
SOUTH
8212' - 10"
THIRD FLOOR
SOUTH
8221' - 9"
FOURTH FLOOR
SOUTH
8230' - 8"
FIRST FLOOR
EAST
8209' - 0"
SECOND FLOOR
EAST
8217' - 11"
THIRD FLOOR
EAST
8226' - 10"
2
A505
TYP.3
LOWER DOOR BEING REPLACED
WITH FIXED WINDOW. UPPER
WINDOW IS MULLED TO THE
DOOR AND WILL NEED TO BE
REPLACED. NOTIFY OWNER
SEE D1/A207
HAVE TO REPLACE.
DOES NOT MATCH.
NOTIFY OWNERA506
7 Sim
A506
2 Sim
A506
1 Sim
A506
7 Sim
EGRESS
43" HT RAILING TYP SNOW FENCE ON METAL ROOF
2
A506
Sim
7
A505
Sim
11
A506
Sim
11
A506
Sim
11
A506
Sim
11
A506
Sim
STONE CAP
NEW GATE OR SLIDING DOOR NEW GARAGE DOOR TRANSOM AND CLADDING TO MATCH BLDG 100 & 200
2 X 6 BETWEEN SIDING AND STUCCO
2 X 6 BETWEEN STONE AND STUCCO
A906
2
1. ALL EXISTING WINDOWS TO BE REPLACED, EXCEPT WHERE NOTED;
CONTRACTOR TO PROVIDE DOOR AND WINDOW SCHEDULE BASED ON
MINIMUM REDUCTION OF EXISTING OPENING DIMENSIONS AND TO VERIFY
EMERGENCY EGRESS REQUIREMENTS FOR NEW WINDOWS
2. MATERIAL COLORS TO MATCH EXISTING ON 100/200 BUILDING (STONE TO
MATCH 300/400 BUILDING)
3. EXISTING CEDAR SHAKE SIDING TO BE REMOVED
4. EXISTING SPLIT-FACE CMU TO REMAIN AND BE COVERED BY NEW MATERIALS
AS PROPOSED AND REPAIRED AS NECESSARY
5. STUCCO TO RECEIVE CONTROL JOINTS PER MFR'S RECOMMENDATION AND
PER PATTERNS INDICATED ON ELEVATIONS
6. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING GUTTERS AND
DOWNSPOUTS AND INSTALL NEW GUTTERS AND DOWNSPOUTS WHERE
NOTED AND BE PLUMB AND HORIZONTAL. RE A101
7. ALL EXISTING HEAT TAPE TO BE REPLACED; NEW HEAT TAPED INSTALLED AT
NEW GUTTERS AND DOWNSPOUTS
8. CONTRACTOR TO REMOVE AND REPLACE EXPOSED UTILITIES AS NEEDED TO
COMPLETE THE WORK IN A NEAT AND WORKMANLIKE MANNER
9. CONTRACTOR TO REMOVE AND REPLACE EXTERIOR LIGHT FIXTURES AND ADD
LIGHT AND OUTLET TO EACH UNIT DECK
10. CONTRACTOR TO CLEAN AND REPAINT ALL DECK STRUCTURE TO REMAIN
11. ALL DECKS TO BE RESURFACED WITH REDWOOD DECKING WITH NEW
FLASHING TO BE INSTALLED AT SURROUNDING WALLS AND EDGE. 1 X 6 AT
UNIT DECKS (EXCEPT AT UNIT 501). 2 X 6 AT COMMON WALKWAYS.
12. ALL EXISTING DRYER VENT TERMINATIONS TO BE REPLACED WITH SEIHO
MODEL SFB-P OR SFB AS APPROPRIATE; ALL OTHER VENT TERMINATIONS TO
BE REPLACED WITH SIMILAR SIMILAR TO MATCH 100/200 BUILDING
13. REPAIR AND PATCH EXISTING GYPSUM BOARD SHEATHING WHERE
NECESSARY WTH PLYWOOD
14. REPLACE EXTERIOR CONDUIT AS NECESSARY AND CONCEAL AS CONDITIONS
ALLOW.
15. REPLACE COMMON WALKWAYS, STAIRS AND DECK STRUCTURE PER STRUCT
ENGINEER.
16. REMOVE AND REPLACE EXISTING PAINT ON TIMBER COLUMNS AT COMMON
WALKWAYS
17. ALL EXISTING CONCRETE WALKWAYS TO REMAIN EXCEPT WHERE NOTED
18.
19.
20. ALL MOUNTING ON HARDIE PLANK SIDING TO USE STURDIMOUNT MOUNTING
BLOCKS
21. REFER TO JAMES HARDE WEBSITE FOR REQUIRED INSTALLATION GUIDELINES
(WWW.JAMESHARDIEPROS.COM) REVIEW THE INSTALLATION INSTRUCTIONS
FOR THESE CRITICAL DETAILS(A) CLEARANCE TO SMF (B) CLEARANCE TO
GRADE, CONC., AND ROOF (C) PRIMING OF SIDES, INCLUDING FIELD CUT
EDGES (D) SEALANT AT LOCATIONS AS REQ'D BY MFGR. (E) MFGR.
RECOMENDED DETAILS AT LAP
GENERAL NOTES
1
CEDAR PLANK - TO BE REMOVED
EXISTING MATERIALS
SPLIT-FACE CMU - TO REMAIN AND
BE COVERED WITH NEW SIDING
ASPHALT
SHINGLES TO
REMAIN
CEMENTIOUS LAP SIDING - 7"
EXPOSURE (MOUNTAIN SAGE - HARDIE
PLANK)¹
PROPOSED MATERIALS
CEMENTIOUS STUCCO
(CROISSANT - SHERWIN WILLIAMS)
¹
STONE¹
¹TO MATCH 100/200 BUILDING
ASPHALT SHINGLES (MATCH
EXISTING)
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
04/16/18
A206
EAST
ELEVATIONBREAKAWAY WEST 500EXTERIOR IMPROVEMENTS1634__963 LIONS RIDGE LOOP, VAIL, CO 8167509/05/17
3/16" = 1'-0"A206
1 EAST ELEVATION - PROPOSED
# DESCRIPTION
1 FIBER CEMENT LAP SIDING, 7" EXPOSURE - COLOR: HARDIE FACTORY-APPLIED MOUNTAIN SAGE
JH50-30 BOTH FACES - ON TYVEK BUILDING WRAP
2 CEMENTITOUS STUCCO - COLOR: SHERWIN WILLIAMS SW7716 CROISSANT - ON TYVEK BUILDING
WRAP
3 BELLY BAND - 2X10 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 VAN BUREN
BROWN
5 WINDOW TRIM - 2X6 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 HASBROUCK
BROWN - OVER VYCOR WINDOW STRIP
8 DECK RAILING - POWDER COATED METAL RAILING TO MATCH 100/200 BLDG - COLOR: BLACK
17 STONE - TO MATCH EXISTING 100/200 BUILDING
18 STUCCO JOINTS TO MATCH 100/200 BUILDING
KEYNOTE LEGEND
1
1
1
1
DRB
APPROVED
5/2/2018 12:00:00
AM
SECOND FLOOR
SOUTH
8212' - 10"
G
NEW REDWOOD DECKING
TO REPLACE EXISTING;
OUTER-MOST DECK FRAMING TO BE
REPLACED WITH PT 4x10 AT ALL
LOCATIONS; PAINT TO MATCH
BELLYBANDS. FLASH AT WALL
INTERFACE
STEEL PLATE RAILING CONNECTION
BOLTS
NEW METAL RAILING TO REPLACE
EXISTING
EXISTING FRAMING TO BE
REPLACED WHERE
NECESSARY
1X4 TO CONCEAL ENDGRAIN OF COMPOSITE
DECKING & PLANK PROUD OF 4X10; NOTCH AT
GUARDRAIL POSTS; TREAT NOTCH CUTS AS
REQ'D BY MFG.
ADD BLOCKING AS REQ'D. TO SUPPORT
NEW PT 4x10 AND RAILING0' - 3 1/2" MAX.GAP BETWEEN PLANKS
AS REQ. BY MFG.
0' - 1"
MIN BEARING PER MFG OF COMP DECKING
11
A505
FACE OF STUCCO BELOW
BLOCKING AS REQ.
NEW HARDIE-PLANK OVER WRB
OVER SHEATHING ON EXIST.
FRAME WALL TO REMAIN
NEW "REAL-TRIM" BRAND
TRIM; MATCH 100/200
NEW RAILING
BACKER ROD AND CAULK
FACE OF BELLYBAND BELOW
KYNAR "L"
FLASHING
LINE OF "L" FLASHING WRAPPING
AROUND AND INTERFACING WITH
"Z" FLASHING
WEATHER RESISTIVE BARRIER
(WRB) (TYVEK OR APPROVED
EQUAL) INSTALLED OVER
SHEATHING AND BLOCKING
0' - 5 1/2"ALIGN TO STUCCO BELOW
7
G
EXISTING CMU
WALL TO REMAIN
NEW STUCCO
NEW RAILING
3 1/2" MAX.
7
NEW HARDI PLANK LAP SIDING
TO REPLACE EXIST. WOOD
SHAKES
EXIST. CMU WALL TO REMAIN
NEW STUCCO ON LATH ON
30# FELT ON WSB ON PLY
EXIST. FRAME WALL AND GYP.
SHEATHING TO REMAIN EXCEPT
WHERE REPLACEMENT / REPAIR IS
NECESSARY
EXIST. SILL PLATES OF FRAME
WALL TO REMAIN
WEATHER - RESITIVE BARRIER (WRB)
(TYVEK OR APPROVED EQUAL) LAP
OVER FLASHING @ B/ WALL
KYNAR "L" FLASHING WITH
HEMMED DRIP EDGE
KYNAR "Z" FLASHING WITH HEMMED
DRIP EDGEMIN0' - 2"PROVIDE WEEPED CASING BEAD
@ STUCCO
0' - 4"
WRB OVER LOWER SMF & BEHIND
UPPER SMF
WRB LAP OVER SMF
KYNAR FLASHING W/
HEMMED DRIP EDGE
NEW BLOCKING
EXISTING BLOCKING
NEW FLASHING
EXISTING DECK JOISTS
NEW REDWOOD
DECKING
EXIST.
SIDING
TYPICAL
EXIST.
WINDOW
TYPICAL
EXIST.
SIDING
TYPICAL
EXIST.
RAILINGS
TYPICAL
EXIST.
CMU
TYPICAL
FIRST FLOOR
SOUTH
8203' - 11"
SECOND FLOOR
SOUTH
8212' - 10"
THIRD FLOOR
SOUTH
8221' - 9"
FOURTH FLOOR
SOUTH
8230' - 8"
10
A505
7
A505
Sim
NEW
SIDING
TYPICAL
NEW
WINDOW
TYPICAL
NEW
RAILINGS
TYPICAL
NEW STUCCO
TYPICAL
NEW
WINDOW
TYPICAL
STUCCO
8
A505
Sim
A505
3 Sim
A505
4 Sim
6
A505
Sim
7
A505
Sim
NEW HARDIE-PLANK OVER BLDG. PAPER
OVER WRB OVER SHEATHING ON EXIST.
FRAME WALL
BLOCKING
AS REQ.
PLYWOOD SHEATHING
WEATHER RESISTIVE BARRIER
(WRB) ( TYVEK OR APPROVED
EQUAL)
SAM FLASHING (TAMKO OR APPROVED
EQUAL) WRAP CORNERS FOUR-INCHES
(4")
BACKER ROD AND CAULK AT SIDING
JOINT - TYPICAL ALL SUCH LOCATIONS
EXIST. WALL FRAMING
"L" FLASHING WRAPPING
AROUND AND INTERFACING W/
"2" FLASH
*SEE (3/A505) AND (2/A505)
FOR FLASHING OF BEAMS
NEW REDWOOD DECKING
TO REPLACE EXISTING
OUTER-MOST DECK FRAMING SHALL BE
REPLACED WITH PT 4x10 AT ALL LOCATIONS;
PAINT TO MATCH BELLYBANDS
STEEL PLATE RAILING CONNECTION;
RE: STRUCT. DWGS.
NEW RAILING TO REPLACE EXISTING
EXISTING FRAMING
TO BE REPLACED
WHERE NECESSARY
P.T. 1 X 4 TO CONCEAL ENDGRAIN OF
COMPOSITE DECKING & PLANK PROW OVER
4X10; NOTCH AT GUARDRAIL POSTS; TREAT
NOTCH CUTS AS REQ'D. BY MFG.
ADD BLOCKING AS
REQ'D. TO SUPPORT
NEW 4x10 AND RAILING
EXIST. STEEL STRUCTURE AND
WOOD BLOCKING
NEW SAM FLASHING AROUND END OF BEAM AS
INDICATED BY DETAILS ON THIS SHEET
RAILING ATTACHMENT PLATE (THICK ENOUGH
TO ALLOW FLASHING TO DRAIN, TYP.)
BACKER ROD AND
SEALENT, TYP.
TRIM
KYNAR "Z" FLASHING w/ DRIP
EDGE
SAM FLASHING (TAMKO OR APPROVED
EQUAL) FOLD OVER EDGE OF BEAM FLANGE
WEATHER RESISTIVE BARRIER (WRB) (TYVEK
OR APPORVED EQUAL), LAP OVER SMF
KYNAR FLASHING
WITH DRIP EDGES EXTENDING
OVER STEEL BEAM AND OVER
EXTRIOR TRIM
PLYWOOD SHEATHING OVER WOOD
BLOCKING
GAP BETWEEN PLANKS
AS REQ. BY MFG.0' - 2"BELLY BAND
COVER FACE OF SAM
W/ TRIM (SEE 3/A505)
STEP 1 STEP 2
STEP 3 STEP 4
2" WRAP
AROUND BEAM
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
04/16/18
A505
DECK
DETAILSBREAKAWAY WEST 500EXTERIOR IMPROVEMENTS1634__963 LIONS RIDGE LOOP, VAIL, CO 8167509/05/17
1 1/2" = 1'-0"A505
10 DECK EDGE SECTION - TYP.
1 1/2" = 1'-0"A505
7 DECK EDGE PLAN - LVL.3 - TYP.
1 1/2" = 1'-0" A505
6 DECK EDGE PLAN - LVL. 1 - TYP.
1 1/2" = 1'-0"A505
11 DECK SIDE WALL TRANSITION SECTION - 2
1/4" = 1'-0"A505
1 DECK ELEVATION - EXISTING
1/4" = 1'-0"A505
2 DECK ELEVATION - PROPOSED
1 1/2" = 1'-0"A505
8 DECK EDGE PLAN - LVL. 2 - TYP.
1 1/2" = 1'-0"A505
9 DECK EDGE @ DRIVE THROUGH
1 1/2" = 1'-0"A505
4 "L" FLASHING ISOMETRIC
1 1/2" = 1'-0"A505
3 MEMBRANE WRAP FOR NEW BEAMS
WD TRIM TO COVER SAM
1
COPPER FLASHING
SWITCH TO KYNAR
FINISH
DRB
APPROVED
5/2/2018 12:00:00
AM
DRB
APPROVED
5/2/2018 12:00:00
AM
DRB
APPROVED
5/2/2018 12:00:00
AM
DRB
APPROVED
5/2/2018 12:00:00
AM
DRB
APPROVED
5/2/2018 12:00:00
AM