Loading...
HomeMy WebLinkAboutF18-0019_Approved Plans_1527006846.pdfGARAGE MECHANICAL MUD ROOM LAUNDRY RES. ENTRY COATS ENTRY BEDROOM WC BATH CLOSET GARAGE RES. ENTRY MECHANICAL SKI ROOM REF.DW W D DW crawlspace SD CM SD A.Sub-Flr dropped ceiling 10' - 7" A.Sub-Flr dropped ceiling11' - 7" A.Sub-Flr dropped ceiling10' - 7" A.Sub-Flr dropped ceiling 9' - 7" A.Sub-Flr dropped ceiling 9' - 1" ceiling at btm of structure above 10'-1" 3'x3' ACCESS DOOR INTO CRAWLSPACE SD CM SD CM PUMP PUMP 1 A4.3 NO SCALE T/S T/S T/S T/S THIS SET OF FIRE SPRINKLER SHOP DRAWINGS HAVE BEEN REVIEWED AND FOUND TO BE ACCEPTABLE BY TIMOTHY N. TROSTEL, JR - N.I.C.E.T. IV # 102055. SR. ENGINEERING TECHNICIAN - FIRE PROTECTION NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINNERING TECHNOLOGIES ____________________________________/____/____ A2.0 MAIN LEVEL8047' - 0" A3.0 UPPER LEVEL 8057' - 9" Plate Height8066' - 1" A1.0 LOWER LEVEL8032' - 0" A1.5 Jr MASTER LVL 8034' - 6" A1.9 MASTER LVL8045' - 10" A1.9 MASTER LVL 8045' - 10" B 0.5 GARAGE8031' - 6" B1.7 MAIN LEVEL8042' - 6" B2.7 UPPER LVL 8055' - 6" 1 A4.2 8036' - 9" 2.75:12 4 A4.2 3 A4.1 1 A4.1 2 A4.2 3 A4.2 4 A4.1 High Plate Height (West)8072' - 3 3/4"East-West High Plate Height8070' - 6" West Living Room High Plate Height8062' - 9 1/2" East Partywall Plate Height 8063' - 7" PARTY WALL East Master High Plate Height 8069' - 10" 8068' - 1" 8065' - 7" 3:12 5 A5.1 1 A5.2 40.50 0.00 22.50 650.00 FLOW TEST: STATIC: 45-10%=40.5 RESIDUAL: 25-10%=22.5 FLOWING: 650 ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS, INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED BY MILE HIGH DESIGN GROUP, LLC THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -MILE HIGHDESIGN GROUP5151 Bannock St.Denver, CO 80216303-291-1012303-383-5023 FAXfiresprinkler@mhdgllc.com A FIRE SPRINKLER DESIGN COMPANY UP DN UP DN REF.DW W D REF. REF.DW A.Sub-Flr dropped ceiling 9' - 1" A.Sub-Flrdropped ceiling9' - 8" A.Sub-Flr dropped ceiling 9' - 1" CLOSET W208 FAMILY ROOM /BEDROOM LANDING LIVING KITCHENDINING POWDER BATH WC A.Sub-Flr dropped ceiling9' - 1" A.Sub-Flrdropped ceiling9' - 1" A.Sub-Flrdropped ceiling 9' - 1" A.Sub-Flr dropped ceiling 9' - 1" CEILING ATBTM OFSTRUCTURE ABOVE11'-9 1/4" 3:12 POWDER DINING KITCHEN MUD ROOM LIVING ENTRY PANTRY LAUNDRY 1 A4.3 LANDING CLOSET BATH CLOSET BATH CLOSET BATH CLOSET CLOSET BATH CLOSET BATH WC BATH WC A.Sub-Flr dropped ceiling9' - 9" A.Sub-Flr dropped ceiling9' - 9" 2.75:12 2.75:12 2:12 2:12 3:12 2:12 3:12 3:12 3:12 A.Sub-Flrdropped ceiling8' - 4" A.Sub-Flr dropped ceiling 8' - 4" A.Sub-Flrdropped ceiling8' - 4" A.Sub-Flr dropped ceiling 8' - 4" A.Sub-Flr dropped ceiling 8' - 4" 2:12 2:12 A.Sub-Flrdropped ceiling9' - 9" A.Sub-Flr dropped ceiling 10' - 1" A.Sub-Flrdropped ceiling10' - 1" 2:12 A.Sub-Flrdropped ceiling9' - 9" BEDROOM BEDROOM UPPER MASTER MASTER BEDROOM BEDROOM LANDING BEDROOM ASSESS CEILING HT INTHIS AREA OVER DOOR TO LEAVE MAXHEIGHT, BUT ENOUGHROOM TO GET FLUEACROSS 3:12 A.Sub-Flr dropped ceiling 8' - 4" DA Name: 1DA Area: 304.82 DA Name: 2DA Area: 287.68 1 A4.3 THIS SET OF FIRE SPRINKLER SHOP DRAWINGS HAVE BEEN REVIEWED AND FOUND TO BE ACCEPTABLE BY TIMOTHY N. TROSTEL, JR - N.I.C.E.T. IV # 102055. SR. ENGINEERING TECHNICIAN - FIRE PROTECTION NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINNERING TECHNOLOGIES ____________________________________/____/____ A2.0 MAIN LEVEL 8047' - 0" A3.0 UPPER LEVEL8057' - 9" Plate Height8066' - 1" A1.0 LOWER LEVEL 8032' - 0" A1.5 Jr MASTER LVL 8034' - 6" A1.9 MASTER LVL 8045' - 10" B 0.5 GARAGE 8031' - 6" B1.7 MAIN LEVEL 8042' - 6" B2.7 UPPER LVL 8055' - 6" High Plate Height (West)8072' - 3 3/4" East Master High Plate Height 8069' - 10" BEDROOM W310 BEDROOM W306 LANDING W301 UPPER MASTER W300 FAMILY ROOM /BEDROOM W205 LANDING W204 KITCHEN W202 DINING W201 GARAGE W100 RES. ENTRY W104 JR. SUITE BEDROOM W107 LANDING E300 MASTER BEDROOM E307 LIVING E200 GARAGE E100 ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS, INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED BY MILE HIGH DESIGN GROUP, LLC THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM - SCALE: Pipe Insulation Detail NTS1 MILE HIGHDESIGN GROUP5151 Bannock St.Denver, CO 80216303-291-1012303-383-5023 FAXfiresprinkler@mhdgllc.com A FIRE SPRINKLERDESIGN COMPANYSCALE: 1/8" = 1'-0" FIRE SPRINKLER PLANS SECTION - GRID A4.3