HomeMy WebLinkAboutF18-0019_Approved Plans_1527006846.pdfGARAGE
MECHANICAL
MUD ROOM LAUNDRY
RES. ENTRY
COATS
ENTRY
BEDROOM
WC
BATH
CLOSET
GARAGE
RES. ENTRY
MECHANICAL
SKI ROOM REF.DW
W D
DW
crawlspace
SD
CM
SD
A.Sub-Flr
dropped ceiling
10' - 7"
A.Sub-Flr
dropped ceiling11' - 7"
A.Sub-Flr
dropped ceiling10' - 7"
A.Sub-Flr
dropped ceiling
9' - 7"
A.Sub-Flr
dropped ceiling
9' - 1"
ceiling at btm of
structure above
10'-1"
3'x3' ACCESS DOOR INTO CRAWLSPACE
SD CM
SD
CM
PUMP
PUMP
1
A4.3
NO SCALE
T/S T/S T/S T/S
THIS SET OF FIRE SPRINKLER SHOP
DRAWINGS HAVE BEEN REVIEWED
AND FOUND TO BE ACCEPTABLE BY
TIMOTHY N. TROSTEL, JR - N.I.C.E.T.
IV # 102055. SR. ENGINEERING
TECHNICIAN - FIRE PROTECTION
NATIONAL INSTITUTE FOR CERTIFICATION IN
ENGINNERING TECHNOLOGIES
____________________________________/____/____
A2.0 MAIN LEVEL8047' - 0"
A3.0 UPPER LEVEL
8057' - 9"
Plate Height8066' - 1"
A1.0 LOWER
LEVEL8032' - 0"
A1.5 Jr MASTER
LVL
8034' - 6"
A1.9 MASTER LVL8045' - 10"
A1.9 MASTER LVL
8045' - 10"
B 0.5 GARAGE8031' - 6"
B1.7 MAIN LEVEL8042' - 6"
B2.7 UPPER LVL
8055' - 6"
1
A4.2
8036' - 9"
2.75:12
4
A4.2
3
A4.1
1
A4.1
2
A4.2
3
A4.2
4
A4.1
High Plate Height
(West)8072' - 3 3/4"East-West High
Plate Height8070' - 6"
West Living Room
High Plate Height8062' - 9 1/2"
East Partywall Plate
Height
8063' - 7"
PARTY
WALL
East Master High
Plate Height
8069' - 10"
8068' - 1"
8065' - 7"
3:12
5
A5.1
1
A5.2
40.50 0.00
22.50 650.00
FLOW TEST:
STATIC: 45-10%=40.5
RESIDUAL: 25-10%=22.5
FLOWING: 650
ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,
INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION
CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE
UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL
IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR
EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR
AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY
TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION
CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR
INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE
COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND
STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN
GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH
ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED
THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED
BY MILE HIGH DESIGN GROUP, LLC
THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT
FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -MILE HIGHDESIGN GROUP5151 Bannock St.Denver, CO 80216303-291-1012303-383-5023 FAXfiresprinkler@mhdgllc.com
A FIRE SPRINKLER
DESIGN COMPANY
UP
DN
UP
DN REF.DW
W D REF. REF.DW
A.Sub-Flr
dropped ceiling
9' - 1"
A.Sub-Flrdropped ceiling9' - 8"
A.Sub-Flr
dropped ceiling
9' - 1"
CLOSET
W208
FAMILY ROOM
/BEDROOM
LANDING
LIVING
KITCHENDINING POWDER
BATH
WC
A.Sub-Flr
dropped ceiling9' - 1"
A.Sub-Flrdropped ceiling9' - 1"
A.Sub-Flrdropped ceiling 9' - 1"
A.Sub-Flr
dropped ceiling
9' - 1"
CEILING ATBTM OFSTRUCTURE
ABOVE11'-9 1/4"
3:12
POWDER DINING
KITCHEN
MUD ROOM
LIVING
ENTRY
PANTRY
LAUNDRY
1
A4.3
LANDING
CLOSET
BATH
CLOSET BATH
CLOSET
BATH
CLOSET CLOSET
BATH
CLOSET
BATH
WC
BATH
WC
A.Sub-Flr
dropped ceiling9' - 9" A.Sub-Flr
dropped ceiling9' - 9"
2.75:12
2.75:12
2:12
2:12
3:12 2:12
3:12
3:12
3:12
A.Sub-Flrdropped ceiling8' - 4"
A.Sub-Flr
dropped ceiling
8' - 4"
A.Sub-Flrdropped ceiling8' - 4"
A.Sub-Flr
dropped ceiling
8' - 4"
A.Sub-Flr
dropped ceiling
8' - 4" 2:12
2:12
A.Sub-Flrdropped ceiling9' - 9"
A.Sub-Flr
dropped ceiling
10' - 1"
A.Sub-Flrdropped ceiling10' - 1" 2:12
A.Sub-Flrdropped ceiling9' - 9"
BEDROOM
BEDROOM
UPPER MASTER
MASTER
BEDROOM
BEDROOM
LANDING
BEDROOM
ASSESS CEILING HT INTHIS AREA OVER
DOOR TO LEAVE MAXHEIGHT, BUT ENOUGHROOM TO GET FLUEACROSS
3:12
A.Sub-Flr
dropped ceiling
8' - 4"
DA Name: 1DA Area: 304.82
DA Name: 2DA Area: 287.68
1
A4.3
THIS SET OF FIRE SPRINKLER SHOP
DRAWINGS HAVE BEEN REVIEWED
AND FOUND TO BE ACCEPTABLE BY
TIMOTHY N. TROSTEL, JR - N.I.C.E.T.
IV # 102055. SR. ENGINEERING
TECHNICIAN - FIRE PROTECTION
NATIONAL INSTITUTE FOR CERTIFICATION IN
ENGINNERING TECHNOLOGIES
____________________________________/____/____
A2.0 MAIN LEVEL
8047' - 0"
A3.0 UPPER LEVEL8057' - 9"
Plate Height8066' - 1"
A1.0 LOWER
LEVEL
8032' - 0"
A1.5 Jr MASTER
LVL
8034' - 6"
A1.9 MASTER LVL
8045' - 10"
B 0.5 GARAGE
8031' - 6"
B1.7 MAIN LEVEL
8042' - 6"
B2.7 UPPER LVL
8055' - 6"
High Plate Height
(West)8072' - 3 3/4"
East Master High
Plate Height
8069' - 10"
BEDROOM
W310
BEDROOM
W306
LANDING
W301
UPPER MASTER
W300
FAMILY ROOM
/BEDROOM
W205
LANDING
W204
KITCHEN
W202 DINING
W201
GARAGE
W100
RES. ENTRY
W104
JR. SUITE
BEDROOM
W107
LANDING
E300
MASTER
BEDROOM
E307
LIVING
E200
GARAGE
E100
ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,
INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION
CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE
UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL
IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR
EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR
AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY
TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION
CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR
INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE
COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND
STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN
GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH
ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED
THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED
BY MILE HIGH DESIGN GROUP, LLC
THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT
FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -
SCALE:
Pipe Insulation Detail
NTS1 MILE HIGHDESIGN GROUP5151 Bannock St.Denver, CO 80216303-291-1012303-383-5023 FAXfiresprinkler@mhdgllc.com
A FIRE SPRINKLERDESIGN COMPANYSCALE: 1/8" = 1'-0"
FIRE SPRINKLER PLANS SECTION - GRID A4.3