HomeMy WebLinkAboutE18-0109_Approved Plans_1528302601.pdf r a 17b m ELECTRICAL SYSTEMS LEGEND ALL SYMBOLSSHOWN ON LEGEND ARE ELECTRICAL SHEET INDEX b NOT NECESSARILY USED. ,?-1 -o _ ISSUE LOG 00 06/06/18 LIGHTING FIXTURE SYMBOLS POWER SYMBOLS ABBREVIATIONS o Co Q RECESSED LIGHTING FIXTURE Q SINGLE RECEPTACLE AFC - ABOVE FINISHED CEILING 0 ri 0 a DIRECTIONAL/ADJUSTABLE RECESSED LIGHTING FIXTURE ec DUPLEX RECEPTACLE AFF - ABOVEFINISHED FLOOR n SURFACE MOUNTED LIGHT CIc DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER AFG - ABOVEFINISHEDGRADE co co co z Lu N. NO N O N2 PENDANT MOUNTED LIGHT � DOUBLE DUPLEX RECEPTACLE AHJ - AUTHORITY HAVING JURISDICTION N V Xi D (V CV 0 Q-I WALL MOUNTED LIGHT ec GFCI DUPLEX RECEPTACLE AL ALUMINUM 00 o 0 0 0 0 0-1 WALL MOUNTED UP-LIGHT ec DUPLEX RECEPTACLE; HALF SWITCHED AP - ACCESS POINT w r� cn cn w O 1>0 MONO-POINT LIGHTING FIXTURE IJP ISOLATED GROUND DUPLEX RECEPTACLE AWG - AMERICAN WIRE GAUGE r- 0) N U 11 RECESSED STEP LIGHT _ rel MULTI-OUTLET PLUG STRIP BAS - BUILDINGAUTOMATION SYSTEM cin oo C\1 0 0 w 1- D W F-0-I FLUORESCENT STRIP LIGHT gL FLUSH CEILING MOUNTED DOUBLE DUPLEX RECEPTACLE BFG - BELOW FINISH GRADE O 0- D- (1 z I J WALL MOUNTED LINEAR FLUORESCENT LIGHT E FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE BMS - BUILDING MANAGEMENT SYSTEM TITLE o 0_ 0 U U U CD w E0.00 ELECTRICAL COVER SHEET 4 4 4 1 4 A/ I2 RECESSED OR SURFACE MOUNTED FLUORESCENT TROFFER ❑® FLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE C - CONDUIT E0.01 ELECTRICAL SCHEDULES 4 4 4 4 '1 40 w V//////A 0 FIXTURE WITH EMERGENCY BACKUP OR ON EM CIRCUIT E FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHED CATV- COMMUNITY(CABLE)ANTENNA TELEVISION SYSTEM E0.99 EXISTING SITE LIGHTING PLAN Al A/ 4 4 4 U C1) CEILING MOUNTED EXIT SIGN W/FACES&ARROWS AS SHOWN ❑® FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOM CCTV- CLOSED CIRCUIT TELEVISION E1.00 PROPOSED ELECTRICAL SITE PLAN Al 4 1f 1f el WALL MOUNTED EXIT SIGN W/FACES&ARROWS AS SHOWN g-i WALL MOUNTED SPECIAL OUTLETAS NOTED CKT - CIRCUIT E1.01 ELECTRICAL LEVELS 1 &2 Al AI 1f A/ -4 .................. EMERGENCY LIGHTS SPECIALOUTLETAS NOTED CPU - CENTRAL PROCESSINGUNIT E1.02 ELECTRICAL LEVELS 3&4 �I 1f 'i 1f 1I 0 �, C, - � ® �' � ►off/ III-0 EXTERIOR POLE MOUNTED LIGHT Q JUNCTION BOX CT - CURRENT TRANSFORMER E4.00 ELECTRICAL ONE-LINE DIAGRAM 4 4 4 A/ A/ A/ A 4,'1 C:;, 1-%1: no EXTERIOR POST(BOLLARD) MOUNTED LIGHT OHWALL MOUNTED JUNCTION BOX DISP GARBAGE DISPOSAL E4.01 ELECTRICAL DIAGRAMS A1 A/ 4 4 4 4 15 Q FLOOR MOUNTED JUNCTION BOX DW - DISHWASHER ISSUE LOG KEY: = '' Vg,.'.4,<<` LIGHTING CONTROL SYMBOLS e DIVISION 15 EQUIPMENTPOWERCONNECTION (E) - EXISTING ' ' NOT PARTOF SETOF SET =��-r6's�0NALS�,+��,►' S SWITCH © TIMER SWITCH EM - EMERGENCY ' * ' ISSUED FOR INFORMATION ONLY '''••■....... S3 THREE-WAY SWITCH ❑., FUSED DISCONNECT EWC - ELECTRIC WATER COOLER GENERAL NOTES: ENGINEER'SSTAMP S4 FOUR-WAY SWITCH IN NON FUSED DISCONNECT FA - FIRE ALARM SJ DOOR JAMB SWITCH ® MOTOR STARTER FACP- FIRE ALARM CONTROL PANEL 1. THESE DRAWINGS ACCOMPANY THE PUBLISHED CONSTRUCTION DOCUMENT SPECIFICATION BOOK(PROJECT MANUAL). 551 N Frontage RCI W, Vail, CO 81657 5K KEY SWITCH ® ENCLOSED CIRCUIT BREAKER FBO - FURNISHED BY OTHERS 2. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGSAND IN FIELD PRIOR TO COMMENCEMENT OF WORK. SV VARIABLE SPEEDSWITCH H PULL BOX GC - GENERAL CONTRACTOR 3. VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS. ST THERMAL OVERLOAD SWITCH 0 PUSH BUTTON GFI - GROUND FAULTCIRCUIT INTERRUPTER 4. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER-IN WRITING. WORK WHICH COULD RESULT IN AN E DIMMER ® TIME CLOCK GRD - GROUND ACCIDENTAL OUTAGE(BEYOND BRANCH CIRCUITS)SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK. E3 THREE-WAY DIMMER 0 PHOTO-CELL IAW - IN ACCORDANCE WITH 5. SERVICE SHALL BE MAINTAINED TO EXISTING AREAS DURING CONSTRUCTION. CONTRACTOR SHALL PROVIDE PORTABLE GENERATORS, n LOW VOLTAGE SWITCH ❑T TRANSFORMER IC - INTERMEDIATE CROSS-CONNECT CABLES,OUTLETS,ETC.AS REQUIRED TO MAINTAIN CONTINUITY OF SERVICE. PLACEMENT OF SUCH PORTABLE EQUIPMENT SHALL BE SUBJECT TO OWNER APPROVAL. ^, So WALL OCCUPANCY SENSOR/SWITCH G PANELBOARD OR LOADCENTER IDF - INTERMEDIATE DISTRIBUTION FRAME I �/ 6. REVIEWARCHITECTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID. t OCCUPANCY SENSOR-WALL MOUNTED E CONTACTOR IG - ISOLATED GROUND 7. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. ® OCCUPANCY SENSOR-CEILING MOUNTED ky ELECTRIC MOTOR IR - INFRARED AO 8. WORK,MATERIALS,AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL,STATE,AND NATIONAL CODES AND <®> OCCUPANCY SENSOR-CORRIDOR CEILING MOUNTED g METER LAN - LOCALAREA NETWORK ORDINANCES. U n DAYLIGHT PHOTO SENSOR O THERMOSTAT MDF - MAIN DISTRIBUTION FRAME 9. PROVIDE PERMITSAND INSPECTIONS REQUIRED. ATS AUTOMATIC TRANSFER SWITCH (N) - NEW 10. PROVIDE 1/4"SCALE LAYOUT DRAWINGS OF ROOMS WITH ELECTRICAL SWITCHBOARDS AND TRANSFORMERS WITH SHOP DRAWING SUBMITTAL. LAYOUTSSHALL SHOW LOCATIONS OF,AND SHALL BE COORDINATED WITH MECHANICAL EQUIPMENT. ALL EQUIPMENT A , CIRCUIT HOMERUN NIC - NOT IN CONTRACT SHALL BE DRAWN TO SCALE. - CONDUIT RUN NL - NIGHT LIGHT 11. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO U) SUBSTITUTE ALTERNATE MATERIALS,EQUIPMENT,OR INSTALLATION METHODS. - CONDUIT RUN BELOW GRADE NTS - NOT TO SCALE 12. VERIFY EXACT LOCATIONSOF EXISTINGAND NEW UNDERGROUND UTILITIES,PIPING AND RACEWAY SYSTEMS PRIOR TO TRENCHING. -0 CONDUIT UP OC - ON CENTER PROVIDE NECESSARY TRENCHING,BACKFILL,EXCAVATION,SUPPORTS,SERVICE FEEDERS(CONDUIT AND/OR WIRE),PULLBOXES, TRANSFORMER PADS,SAWCUTTING AND PATCHING,CONCRETE/PAVING,ETC.REQUIRED. BACKFILL TRENCHES TO 90 PERCENT -a CONDUIT DOWN PA - PUBLIC ADDRESS COMPACTION AND PATCH TO MATCH EXISTING. CONTRACTOR SHALL OBTAIN AND VERIFY EXACT UTILITY COMPANY DRAWINGSAND ■ REQUIREMENTS. ELECTRICAL CONTRACTOR IS TO SUBMIT A COMPLETE CONSTRUCTION DRAWINGSET TO THE ELECTRICAL UTILITY S SWITCH REF - REFRIGERATOR COMPANY WITH-IN 10 DAYS OF AWARD OF CONTRACT. COORDINATE TIMELINE OF THEIR REVIEW,APPROVAL,CONSTRUCTION SCHEDULINGAND INSTALLATION OF THE UTILITY TRANSFORMER WITH THE UTILITY COMPANY. NOTIFY OWNER OF ANY SCHEDULING L. ST THERMAL OVERLOAD SWITCH TTB - TELECOMMUNICATIONS TERMINAL BOARD CONFLICTS. 5V VARIABLE SPEEDSWITCH TVSS - TRANSIENT VOLTAGE SURGE SUPPRESSOR 13. EXISTING SYSTEMSANDCONDITIONS SHOWN ON DRAWINGS FOR EXISTING BUILDINGS ARE TO BE NOTED"FOR GUIDANCE ONLY". THE CO ELECTRICAL CONTRACTOR TO FIELD CHECK ALL EXISTING CONDITIONS PRIOR TO BIDDING AND TO INCLUDE IN HIS BID AN ALLOWANCE SK KEYSWITCH TVTB - TELEVISION TERMINAL BOARD FOR REMOVAL AND/OR RELOCATION OF EXISTING CONDUITS,WIRES,DEVICES,FIXTURES,OR OTHER EQUIPMENT AS INDICATED ON THECL PLANS OR AS REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL SYSTEM TO ALL OTHER WORK AS REQUIRED UG - UNDERGROUND 14. PROVIDE ELECTRICAL DEMOLITION REQUIRED. REFER TO ARCHITECTURAL AND ELECTRICAL DEMOLITION DRAWINGS FOR LOCATION AND ' ONE-LINE DIAGRAM SYMBOLS UNO - UNLESS NOTED OTHERWISE EXTENT OF DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. - DISCONNECT SWITCH V - VOLT 15. PROVIDE ALL NECESSARY DEMOLITION TO REMOVE EXISTING UNUSED CONDUIT,WIRE,CABLE,J-BOXES,RECEPTACLES,SWITCHES, LIGHTS,FIRE ALARMS DEVICES,ETC. COMPLETE WITH ASSOCIATED CIRCUITING TO SOURCE. WHERE IT IS NOT FEASIBLE TO REMOVE II I I FUSE W - WATT THE ABOVE,OUTLET SHALL BE ABANDONED,WIRE REMOVED,AND BLANK COVER PLATES PROVIDED. L. _(Th_ CIRCUIT BREAKER WAN - WIDE AREA NETWORK 16. ALL(E)EQUIPMENT,LAMPS,BALLASTS, ETC.BEING REMOVED SHALL BE DISCARDED IN ACCORDANCE WITH APPLICABLE EPA F C13 CURRENT TRANSFORMER WAP - WIRELESSACCESS POINT REQUIREMENTS. I 1 I A-•-3E17. EXISTING LIGHT FIXTURES,ELECTRICAL EQUIPMENT,ETC. BEING REMOVED SHALL BE RETURNED TO THE OWNER,EXCEPT FOR THOSE Wj C POTENTIAL TRANSFORMER WLAN- WIRELESS LOCAL AREA NETWORK ITEMS BEING RELOCATED. W O METER WP - WEATHERPROOF 18. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN. 2 (') Q VOLT-METER XP - EXPLOSIONPROOF 19. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO /'1i Q AMP-METER +18" - MOUNTING HEIGHT TO CENTERLINE OF THE ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION. �,/ DEVICEABOVE FINISH FLOOR(VERIFY W/ARCH ELEVS) 20. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS,DETAILS,AND SS SURGE SUPPRESSION DEVICE INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH gr SELECTOR SWITCH EQUIPMENT ACTUALLY SUPPLIED. UJ ILI 21. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED 0- GROUND FAULT PROTECTION UNDER THIS SECTION,OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. NOTES: n' CD- SHUNT TRIP 22. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L.OR OTHER RECOGNIZED TESTING FACILITY. O W NORMALLY OPEN CONTACT LIGHT LINEWEIGHT INDICATES EXISTING. 23. WIRING DEVICESSHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES,AND20 AMPERES FOR DUPLEX C -kr- NORMALLY CLOSED CONTACT - HATCHED AREAS INDICATE DEMOLITION. ////// RECEPTACLES. THE COLOR OF THE DEVICESAND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT. ) O 24. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS. EMT FITTINGS SHALL BE MALLEABLE IRON OR STEEL. CONNECTORS v GROUND - 'CC'ADJACENT TO A DEVICE INDICATES CQ SHALL BE INSULATED THROATTYPE. MINIMUM CONDUIT SIZE IS 3/4". FOLLOW NEC FOR MAXIMUM NUMBER OF CONDUCTORS PER J �I Q COLD WATER GROUND CONNECTION MOUNTING ABOVE COUNTERTOP. CONDUIT. CONDUIT SHALL BE OF SUFFICIENT SIZE AND CONDUCTOR QUANTITY SHALL BE LIMITED TO ELIMINATE THE NEED TO DE-RATE ♦/� CONDUCTORS. METAL CLAD CABLE IS[NOT]PERMITTED. v, I BUILDING STEEL GROUND CONNECTION 25. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A200LBNYLON PULL STRING OREQUAL,AND SHALL BEIDENTIFIED ATALL JUNCTION,PULL ♦ ` AND TERMINATION POINTS,USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT,ORIGINATION,AND V TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT. 26. WIRE SHALL BE COPPER,75 DEGREE CELSIUS RATED FOR GENERAL USE. WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE11 CU SHALL BE COPPER,MINIMUM 90 DEGREE CELSIUS RATED.SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREE CELSIUS AMBIENT. CONDUCTORAMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS. F U) 27. PROVIDE NEW UPDATED PANELBOARD DIRECTORIES FOR EXISTING AND NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT. / , 28. PANEL DIRECTORIES SHALL BE REMOVABLE. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES SHALL BE TYPEDAND INSTALLED UNDER CLEAR PLASTIC COVERS. LLI 29. FINAL CONNECTIONS TO MOTORS,TRANSFORMERS,AND OTHER VIBRATING EQUIPMENT SHALL BE SEAL TITE FLEX AND APPROVED J FITTINGS. DO NOT SECURE CONDUITS,DISCONNECTS,OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT. 30. FIRE ALARM,SOUND,TELEPHONE,COMPUTER AND SIMILAR SYSTEMS CONDUITS LARGER THAN 1"SHALL HAVE LONG RADIUS SWEEPS(12 LLI I2 TIMES THE DIAMETER). 31. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE,CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO OWNER. 32. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 33. SYSTEMS SHALL BE COMPLETE,OPERABLE,AND READY FOR CONTINUOUS OPERATION. LIGHTS,SWITCHES,RECEPTACLES,MOTORS, O ETC.SHALL BE CONNECTEDAND OPERABLE. 0 ■ 0 NE O "' WN O � N n1 0 > o . to o al ti ♦, ch t co ca ch W (II E ,mii/Ill�■ .,s ti W 2 U 1::::01 l 0 (0y r .CO 113 > Q 2 O '�C���u N = O " ��u � CD V 07M a C1� c w 1_��1 000- z (n iii Illl U IY� (a („i L 0) Iri4 ilco 03'03 V 0) LVJ D_ O 0 c/�� W co ce u) Ow Q ce coco I_ N 00 LL ti: CL a 0 0 o m J Q L Nli••� O c inC...7 c m o E 5 c U i..e LLI m U InO Q U c CS 0 U systems f u I I H e d a) o u)• coN o 303.278.3820 wwwbgbuildingworks corn ■ L ti 0 .A Project No.9864.00 Copyright 2017 i o U M ALBUQUERQUEIAVONIDENVERIFORTCOLLINS Q p °F I/4 iti15 Branch Panel: MDP MECHANICAL EQUIPMENT SCHEDULE LUMINAIRE SCHEDULE e iib Location: MECHANICAL 5 Volts: 120/208 Wye A.I.C.Rating: 22,000 VOLT/ DISCONNECT/FUSE LUMEN MARK DESCRIPTION HP WATTS FLA MCA MOCP FEEDER CIRCUIT SPECIFIC NOTES TYPE DESCRIPTION MOUNTING COLOR INPUT WATTS VOLT MANUFACTURER CATALOG NUMBER SPECIFIC Supply From: Utility Phases: 3 Bus Rating 1200A PHASE SIZE OUTPUT TEMP.(K) NOTES 06/06/18 Mounting: Surface Wires: 4 MLO or MCB: MLO 1P MOTOR RATED TOV STANDARD PARKING STRUCTURE LIGHT,BLACK Enclosure:Type 1 MCB Rating: 1200 A HRV-1 BATHROOM VENTILATOR 120/1 300 2.5 3.1 20A/1P SWITCH 20A(2WG) MDP-46 G1 FINISH,INTEGRAL OCCUPANCY SENSOR PENDANT 8066 5000 69 120 CREE PKG-3045M PD 06 E UL BK 350ML (1) NO. LOAD DESCRIPTION TYPE POLE TRIP A B C TRIP POLE TYPE LOAD DESCRIPTION NO. 1P MOTOR RATED TOV STANDARD PARKING STRUCTURE LIGHT,BLACK 1 MECH 5 R 1 20 A 360 1160 20 A 1 E LEVEL 1 ENTRY GATE 2 EF-1 GARAGE EXHAUST FAN#1 120/1 3/4 1656 13.8 17.3 20A/1P SWITCH 20A(2WG) SEE PLANS 3 IT 9 R 1 20 A 540 1160 20 A 1 E LEVEL2 ENTRY GATE 4 G1E FINISH,INTEGRAL OCCUPANCY SENSOR,EMERGENCY PENDANT 8066 5000 69 120 CREE PKG-3045M PD 06 E UL BK 350 ML (1) BATTERY BACKUP 5 MALE 6/FEMALE 7 R 1 20 A 360 1160 20 A 1 E LEVEL 3 ENTRY GATE 6 1P MOTOR RATED 20A(2WG)EF-2 CEILING EXHAUST FAN 120/1 224 1.9 2.3 20A/1P SWITCH ( ) MDP-53 7 MALE 6 HAND DRYER E 1 20 A 1300 1160 20 A 1 E LEVEL ENTRY GATE 8 9 FEMALE 7 HAND DRY E 1 20 A 1300 209 20 A 1 L LEVEL 1 LIGHTING 10 S1 4FT LED STRIP LIGHT SURFACE 2500 4000 23 120 CREE LS4 25L 40K 10V 11 LEVEL 1 REC R 1 20 A 540 552 20 A 1 L LEVEL 1 GARAGE 12 WH-1 ELECTRIC WATER HEATER 208/3 -- 12000 33.3 41.7 50A/3P 60A,3 P,NF 50A(3 WG) MDP-52,54,56 13 LEVEL 1 REC R 1 20 A 540 621 20 A 1 L LEVEL2 GARAGE 14 4FT LED STRIP LIGHT WITH EMERGENCY BATTERY 15 LEVEL 2 REC R 1 20 A 1080 642 20 A 1 L LEVEL 3 GARAGE 16 P-1 DOMESTIC HOT WATER 120/1 25 0.2 0.3 20A/1P 1P MOTOR RATED 20A(2WG) MDP-55 S1E BACKUP SURFACE 2500 4000 23 120 CREE LS4 25L 40K 10V EB14 17 LEVEL 3 REC R 1 20 A 900 225 20 A 1 L EAST STAIR TOWER 18 RECIRC PUMP SWITCH ( ) w 19 LEVEL REC R 1 20 A 720 200 20 A 1 L WEST STAIR TOWER 20 CEILING MOUNTED UNIT MDP-48,50 TOV STANDARD LED POLE LIGHT WITH INTEGRAL 21 LEVEL 1 CAR CHARGE E 2 40 A 3328 168 20 A 2 L LEVEL4 LIGHTING 22 UH-1 HEATER 208/1 3700 17.8 22.2 25A/2P 30A,2P,NF 30A(2WG) MDP-62,64 SP1 PHOTOCELL BLACK FINISH-16FT ROUND STEEL POLE POLE 5327 4000 56 208 PHILLIPS 55W32LED4KLE4 UNIV DMG PH8 (1)(2) 23 3328 168 24 WALL RECESSED CABINET MDP-38,40 LLJ 25 LEVEL CAR CHARGE E 2 40 A 3328 1500 20 A 1 L EM INVERTER(1) 26 CUH-1 208/1 2000 9.6 12.0 20A/2P 30A,2P,NF 20A(2WG)UNIT HEATER ( ) MDP-42,44TOV STANDARD LED POLE LIGHT,BLACK FINISH-14FT 27 -- -- -- -- 3328 1380 30A 2 E HEATTRACE(2) 28 SP2 ROUND STEEL POLE POLE 5327 4000 56 208 PHILLIPS 55W32LED4KLE4 UNIV DMG (1)(3) I- 29 LEVEL3CARCHARGE E 2 40A 3328 1380 -- -- -- -- 30 DC-1 HRV PREHEAT COIL 208/3 -- 4100 11.4 14.2 20A/3P 30A,3P,NF 20A(3WG) MDP-32,34,36 0 w 31 -- -- -- -- 3328 1367 20 A 3 E DC-1 32 4FT VANDAL RESISTANT LED WALL SURFACE MOUNTED 33 LEVEL CAR CHARGE E 2 40 A 3328 1367 -- -- -- -- 34 GENERAL NOTES: W1 FIXTURE SURFACE 2836 4000 25 120 LUMINAIRE CLF7446" 25W 4000K CP GRY U r/1 35 -- -- -- -- 3328 1367 -- -- -- -- 36 A. SEE SPECIFICATIONS FOR ELECTRICAL DIVISION AND MECHANICAL DIVISION MOTOR STARTER COORDINATION. v v J 37 LEVEL 4 CAR CHARGE E 2 40 A 3328 1000 20 A 2 E CUH-1-MALE 6 38 B. PROVIDE PHASE PROTECTION FOR ALL THREE PHASE MOTORS ABOVE 7-1/2 HP. 4FT VANDAL RESISTANT LED WALL SURFACE MOUNTED W1E SURFACE 2836 4000 25 120 LUMINAIRE CLF74 46"-25W 4000K CP GRY EMB722 +++ +R,„„+ 39 -- -- -- -- 3328 1000 -- -- -- -- 40 C. PROVIDE ALL EXTERIOR DISCONNECTS WITH NEMA 3 R RATING. FIXTURE ,r 41 EF-1-LEVEL 1 M 1 20 A 1656 1000 20 A 2 E CUH-1-FEMALE 7 42 D. WHEN EQUIPMENT IS LISTED WITH ONLY A HORSEPOWER RATING THE DISCONNECT AND FEEDER ARE SIZED PER THE N.E.C. ++��'O �►b t/C,. 43 EF-1-LEVEL 1 M 1 20 A 1656 1000 -- -- -- -- 44 SPECIFIC NOTES: LED WALL PACK AT GARAGE ENTRANCE WITH INTEGRAL 11 O,', 5 ` - W2 SURFACE 6368 4000 90 120-277 CREE SEC-EDG 2MB WM 08 E UL BZ 350 P + c ) 45 EF-1-LEVEL 1 M 1 20 A 1656 300 20 A 1 M HRV-1 46 (1) PHOTOCELL : ;;. Z: 47 EF-1-LEVEL 2 M 1 20 A 1656 1850 25 A 2 E UH-1-MECH 5 48 (2) 15 49 EF-1-LEVEL 2 M 1 20 A 1656 1850 -- -- -- -- 50 (3) LED WALL PACK AT GARAGE ENTRANCE WITH INTEGRAL W2E SURFACE 6368 4000 90 120-277 CREE SEC-EDG 2MB WM 08 E UL BZ 350 P : -o '•, 51 EF-1-LEVEL 2 M 1 20 A 1656 4000 20 A 3 E WH-1 52 (4) PHOTOCELL PROTECTED WITH POWER INVERTER. =/0,,,....3-8rVg.:' `�r 53 I EF-2 M 1 20 A 448 4000 -- -- -- -- 54 SINGLE FACE EXIT SIGN WITH GREEN LETTERS, =; .f•.'.••••,••.•�N�+,Ft 55 P-1 M 1 20 A 25 4000 -- -- -- -- 56 - `�.570NAL E�+++y 57 MONUMENT SIGN E 1 20 A 1000 112 20 A 2 L SITE LIGHTING 58 X1 EMERGENCY BATTERY BACKUP, INTERNAL HEATER SURFACE 2.8 120 DUAL LITE S G W E HTR .,,,,,,.++' 59 MONUMENT SIGN E 1 20 A 1000 112 -- -- 60 ENGINEER'SSTAMP 61 MONUMENT SIGN E 1 20 A 1000 1850 20 A 2 E UH-1-IT 9 62 DOUBLE FACE EXIT SIGN WITH GREEN LETTERS, 63 Spare -- 1 20 A 0 1850 -- -- -- -- 64 X2 EMERGENCY BATTERY BACKUP,INTERNAL HEATER SURFACE 2.8 120 DUAL LITE S G W E HTR 65 Spare -- 1 20 A 0 0 20 A 1 -- Spare 66 551 N Frontage Rd W, Vail, 67 Spare -- 1 20 A 0 0 40 A 3 -- PV INVERTER 68 SINGLE FACE EXIT SIGN WITH GREEN LETTERS, 69 Spare -- 1 20 A 0 0 -- -- -- -- 70 X3 EMERGENCY BATTERY BACKUP, INTERNAL HEATER WALL MOUNT 2.8 120 DUAL LITE S G W E HTR CO 81657 71 Spare -- 1 20 A 0 0 -- -- -- -- 72 A B C Total Load: 32949 VA 32732VA 28358 VA EM1 EMERGENCY EGRESS FIXTURE WITH LOW-TEMP OPTION WALL MOUNT 675 -- 20.64 120 HOLOPHANE DM90X654 LPO5VS P3 Total Amps: 280 A 278 A 236A GENERAL NOTES: LOAD CLASSIFICATION FEEDER SUBTOTAL DEMAND FACTOR FEEDER TOTAL A. THE LUMINAIRE SCHEDULE CAN NOT BE USED INDEPENDENTLY OF THE DRAWINGS AND SPECIFICATIONS TO OBTAIN LUMINAIRE COSTS. THE INDIVIDUAL ESTABLISHING LUMINAIRE COSTS SHALL PANEL TOTALS NOT QUOTE PRICING WITHOUT FIRST SEEING APPLICABLE ELECTRICAL DRAWINGS AND ELECTRICAL DIVISION SPECIFICATIONS. THE CONTRACTOR IS REPONSIBLE FOR PROVIDING NECESSARY Lighting 4509 VA 125% 5636VA DRAWINGS AND SPECIFICATIONS TO THE INDIVIDUAL QUOTING LUMINAIRE PRICING. Receptacles 5040 VA Per Nec 220 5040 VA TOTAL LOAD: 95.6 kVA B. REFER TO DRAWINGS FOR FIXTURES REQUIRING EMERGENCY BATTERY BACKUP OPTION(SHOWN BY HATCH IN/OVER SYMBOL).MINIMUM LIGHT OUTPUT FOR EM BALLAST SHALL BE 600 LUMENS. Motors 10709 VA Per NEC 430.24 11123 VA C. ALL FLUORESCENT LAMPS ARE TO BE 3500°KELVIN COLOR TEMPERATURE a) Equipment 73 780 VA 100% 73 780 VA TOTAL 265 A SPECIFIC NOTES: 111 Appliances 0 VA Per NEC 220.56 0 VA CURRENT: (1) TOWN OF VAIL STANDARD FIXTURES-ALTERNATES WILL NOT BE CONSIDERED. Specifc Notes: (2) POLE-PHILIPS LUMEC#SPR5J16 (3) POLE-PHILIPS LUMEC#SPR5J14 A. (1) PROVIDE HANDLE LOCK ON CIRCUIT BREAKER. (2)PROVIDE 30-mAGFEP CIRCUIT BREAKER. (4) U 11 Al CO 0) C N . CU I1 I Si c CO �0 v/ C I (1) J E D 0 O w W Z a) OC c O —I V%Q U C CC CU F- (/) U -C:3w O w Q O • O N - ONN LV N `O co <i)o H Li C . CD VJ O � ) ti Z a) o W U fV 0 O g ,_, A J Vp .50) W >n az 1 co a, T,N = o M J M co <.O , W � I- -2o z ► Ln o A U al -0ZE cz LU CO2 IR co -0 LC) LLJ (9 a) c L(6 L N p_ O o (n •L W W CD > ci) Etco O W O rx co S_ 2 in __ (�2 E o J i1 /� J To I..L O O o W CDCO 5 L 2- CD O (3 Ct a) i C C .5 c U Ce LLJ m U o Q U 66 : ig BUOLJ NGWO KS � O` o> Q U C7 CC CD systems fulfMed a) o N 303.278.3820 wwwbgbuildingworks corn ■ U Project No.9864.00 Copyright 2017 i o U co ALBUQUERQUE IAVON IDENVER IFORTCOLLINS Q tv la IL r 1▪71' V OfE IN} Q07 H7 , De 1,0 OF ge. 06/06/18 w amen iiiv _____ itiolwal_11, 1,______ , Ltip..............0,0 "iikatravaill *17111111►�1111 ---------______-------______ iffir 1 I � w 0 w U to er,Af law/ . i **Q iv ri • 1 ,�''o`'\ 1 / / 0. • ' - -.- ,..... ,,,,.. til, I off ,Likill --........._________________ 4 gs a, ............4.7 -11,..„______ * a hkik 4 ...... .. maw °,�n_ ,ft A,aa en ,......._ , --.................. fill • -_-:......._. NW ilk 1 ens fie . ii _ If W isaija a ��'gii ftlx,Air U ►- , ENGINEER'SSTAMP ,,___ ____ ___ ____ 8 L-------- _____ ____ .............................,1C � = 551N Frontage Rd W, Vail, or.awl l ` `'riisszto111. u�tar'r-s.ieraste.., .fPjf� — •� a -� 11W21'1/11/Ta. __ CO 81657 L. ti wils, i , rair, 4 i 1 �zza, o 4 �•1 ealliMirth 4, 113. 1st " 0 _ ............3111.1111ph,..L. a ____ 1 11 Till 0 0 illir6s , ,.....L1 �r.•��t���;' ��'?r►,�. SO ' 1111 �. �a sr......,....... .... �.. ire �� J �I`I 111111 i �� �I Akfausoo avtiivv�pormsvwsr �� JNIMMII A... , eft all -_____Ati a- N �� w# as * ----L--- ------ I / . a oiftmemei �irri�/�. �� : ► �sitrr�r�i j'�� �s� -04-14,-.4%...,...... �`` sr r ��R��� spa-- ........ ui �f �: sl �o� �' C� �s 1111111 % — e. �LIt j/rr�r i1s���%���r�iil!1. \ �i�,��l��a aft" ; I� �� oSSa 0) 00 .- 00 Yo2 R 0_ % 1 .. 1 cV OiiiDo i 11 YO 11 gal71a J n ° SIr c3 c 00 1 0 o I °oZ E H 0 1„......H........11.1 �1,........„ 0 I-1-1I C� __'lli — .J...../ 0111111 0 lop iiii_� 111111231.0' NO SCOPE OF WORK IN THIS AREA. H '/#‘ �O 2 a 111111 I 0 0 : ---3 0 n .O L _ 0. FLAG NOTES: Z CO I REMOVE EXISTING LIGHT. PRESERVE . co EXISTING CIRCUIT FOR REUSE. H 11P 2 REMOVE AND SALVAGE EXISTING LIGHT. V j, PRESERVE EXISTING CIRCUIT FOR REUSE. a) X LLI I2 • o _ ,aos1O CD • aos / : -,,,, Ili ON ao ti O 2 NO Ili N °° co M N O Q' III"I `� SII (II:1111 mwr. I�ILIII ,` ♦, ch W °' (II���P o cfl (II E co !61,IIIh a� O J U a) m 61 W iiik Io IIP ti III1Itl1;IIP � 0)1.--- ' H r Illlllrlll Q Z l�l�ull N = O CO IIIC�I��I Iu N co V �M C1111�I `� CII'I[,I, o II ti Et z -0 U w tr4. 1 u-lco i U L m ca Existing Site Lighting i O 0 SCALE: 1" = 20'-0" + •c W ce c 1 w w co ce - W CD4 cpo !` - Q o To I C CD O O C EY _i O co co C...7 C Es p U EtU OIne d cp Q U 6 systems fulfilled o N o 303.278.3820 wwwbgbuildingworks com ■ L (Ni Project No.9864.00 Copyright 2017 i o U ALBUQUERQUE I AVON I DENVER I FORTCOLLINS Q p iakv OF le :rf:404410,41/e iu fro. r at �Q07� 06/06/18 ft al imVit W - !II'1j►���1 I iftwqest _is., -,.....„„,... w / . si---- _ I � 0 W .....i....4, 41, 111W I111111►11iy� w"�11d+ - _ _il 1 ' 11:•,..'/3eit--1:s_ ci .6::i: - I +++frrrrrrrrr :. „„„„p,,,,,, la 1111111111141111---:1 — —_ m /III ,L A ir Alla _fa%1 _0•1641:-"-"-"-"-"-"-"-"-"Za. I-I lyirr, ENGINEER'SSTAMP 0 W 73 ��! � kMille iftlei el- Issim- II�I�I�■�°!s�/rs '�����L�� �� . _ t g Rd a ' rll 'y-1s� ��� 551N Fron a e W V itPP- ok Vis_. �•__ - ■c '�� �1ilLC�JIs�� pa„� �j a�liz.*„.z �l)�" �- •��� _ i� '� �o = CO81657 ( ‘ -51. a‘ t` Io �II /III o � ;' III „I 1_r� _ o ----iilr------at.....:.*::'" r I/ befilf. e i \iv neftemor anti (kJ ,- \ I II �I� L / AMMMMMmmIfit 41.„ ' ; � j 0 a ,I i I /iii , - - 6 I IDiiiiii 0 0ti ,.......__I ai- ' , L, ,___. ........jur I all lard* �.>. I ilit is �`` �■ ■I�j �n mill teaI # = , , i� ,� 7. ■■ ■■ ear \ _i_. • 0.7,„_ teli,r,,..0„,Tial .4,01..,01_,,_, __,_____„_.14,,,,..7,47,7tm.s... c—, , - ____ i ......... 0 44t......, . ... lie 41011 ja„.i.,.._t.„----____ .1_...4,,:ii.„.„..„1„0,,,,.._._;0,00 igamew-------0--E----0***gazzortro--- 1,„ .____••‘•• , 1 ,•4•41-444.4414,1,:z.*arm Neirmillser any* gi EXISTING COMMUNICATION `- �'� t ii. � NO SCOPE OF WORK IN THIS AREA. SP1 ___ ~� iii 6 _iii„„,�..._ :.? ---F— PEDESTAL.BURY PEDESTAL IN , oOL - �J�� . / • ., }, li HANDHOLE AND EXTEND tai CONDUIT TO NEW PEDESTAL. MDP-58,60 —_� /GARAGE MATCHLI •_ �`� , _ I \ (3) RE:CIVIL. i NE _al�e'•o �� , 12 •SP1 . © O MDP 58,60 �,.� 0 4 A1 (1)4"C.ROUTED Q \ 1 BELOW GRADE. C RE:CIVIL. 1101 O 1 ■ / 000. ffissinzisammIlli (3)4"C.ROUTED ainint._ BELOW GRADE ' ,• ' I I 11 11 _- 1TO IT ROOMo / - �� OZ_ _ __ - ir _ `oo - - CO _I CL Aie if, ), , ni / ills 1 • 11-------__________ _ _ , Art: 1111111P/ /11// \\ II • CZ Japt alIiimit 2--------...,/,,-_.__-..-,-- __________% o . / 0 , -----1 ,i — I -1, CT CABINET AND ........... =— • 1/1 .'��� � MAIN SERVICE �� OMDP5860 = 1 DISCONNECT.� 1 O - [jjj Y1 V /11111°1 C 1/ 11.----OliI, E ` 1 � o �gni IIIII��-���1 raw ----=� -- - - ia) 1 1 i m it_____ _________. ' , I •�, --------- I • (..)1:2 ______• 1 n uuuuw o 4 MDP-57Oil1.111111, W ------ ---_-- SC 'll" SP1 --------a\ jj______Ajfis 1 � LLI cWn 16 nil 03� DE. � • O O. W O -Fr, \ \ \- MDP-58,60 muIImo , s 12 ��� � ��B►�� MDP-59 *r_P1 � 0)00_ I2°�% s12SP1 ri, 1060, � o • FLAG NOTES: 0. • • • o ��� �, EG0�0s 1 UTILITY TRANSFORMER CD ��� / 2 FIBER PEDESTAL.RE: CIVIL. o ct -� ` N O ill10 3 REFER TO ELECTRICAL ONE LINE W o DIAGRAM ON SHEET E4.00 FOR FEEDER SIZE. ����� 4 CONDUITNFROM T SIGN MDPOTO WEA HOERIPROOF lu;i � rAl* JUNCTION BOX LOCATION. � _ 1.0000000000000 5 REPLACE EXISTING POLE LIGHT WITH NEW (In o POLE LIGHT. DISCONNECT EXISTING LIGHT (1:1III ti AND RECONNECT TO NEW LIGHT. ♦ uu CC (,2 co W _F., N CD 0 O (II E 6 STUB UP CONDUIT TO GRADE FOR li„„�IIV' a), o J FUTURE EXPANSION. I'~IIP (73 1.1.1 �, 4 (CV � y r ��co MDP-61 7 PROVIDE(2)4"C. FROM IT ROOM TO VAIL co m Q c GYMNASTICS BUILDING. COORDINATE liC;'t = c3 EXACT TERMINATION POINTS WITH VAIL �`'> / GYMNASTICS BUILDING. RE: CIVIL. C1 , CO �';''rpl O iii !I U8 COMMUNICATIONS HAND HOLE ` U IN-GRADE.PROVIDEBOX SIZED 24"W Xcci - comco 0 30"L, DEPTH AS REQ'D.RE: CIVIL. i w 'g o 9 EXISTING FIBER MANHOLE. EXTEND (1)4" w 11> �' C.TO NEW FIBER PEDESTAL.RE:CIVIL. 10 INCLUDED IN PARKING GARAGE SCOPE OF O w w WORK. 0 0 11 REUSE EXISTING ELECTRICAL CIRCUIT ce cC SERVING EXISTING POLE LIGHT SHOWNc 1- ON EXISTING SITE PLAN. ii=_ 12 FIXTURE SHALL BE CONTROLLED VIA 0_ a co U ELECTRICAL SITE PLAN INTEGRAL PHOTOCELL. o oo J • ci SCALE: 1" = 20'-0" 0 17 a CD U Q� -8 C...7 . 2 .5 c U Inem 0 0 W : IgBUDLDD�GWO [ o _ C7 '� ° c r U systems fui � uiled • o N cm E) 303.278.3820 wwwbgbuildingworks corn L c� Project No.9864.00 Copyright 2017 i o U ALBUQUERQUE I AVON I DENVER I FORT COLLINS Q p ,siti CFI, AN:4044.44, 4;40(5 M. POWER -POI 1QOJ'o 1. ELECTRICAL CONDUIT SHALL BE ROUTED 06/06/18 TIGHT TO STRUCTURE BACK. 2. 'G1' FIXTURES SHALL BE CONTROLLED VIA INTEGRAL MOTION SENSOR.WHEN MOTION IS DETECTED,FIXTURE BRIGHTNESS GOES TO 100%. WHEN NO MOTION IS DETECTED FOR 30 MINUTES,FIXTURE AUTOMATICALLY SETBACK TO 50%. 0 0 0 4 0 6 0 8 9 10 3. ALL EXIT SIGNS SHALL BE CIRCUITED TO LOCAL LIGHTING CIRCUIT. 0 FLAG NOTES: w 1 AUTO-GATE, PROVIDE CONDUITS WITH w PULL STRING FOR POWER AND DATA �y 1 —1 CONNECTION.COORDINATE JUNCTION LL I— BOX INSTALLATION LOCATION WITH (DC) (HRV) MDP-11 MDP-45® A MANUFACTURERSPRODUCTDATA, 0 UJ 6 1 MDP O MDP-11 NP W WP v WP PLANS,AND INSTRUCTIONAL MANUAL. U (n O _ MDP-41 -21,23 2 MDP-43 MDP-11 Si E 2 PROVIDE 40A(2WG)TO JUNCTION BOX l MDP-1 MECHANIC L FOR ELECTRIC CAR CHARGER. PROVIDE +,,r" "• CAT6 CABLE CHARGING STATION. 0 or- ,,0_ /C,. EF rj 2 3 PROVIDE JUNCTION BOX FOR OWNER ,/• - ; \ ' / s1E PROVIDED, OWNER INSTALLED CCTV 15 • CAMERA. MOUNT AT 90"AFF.PROVIDE 1"C. ' • rr FROM JUNCTION BOX BACK TO IT ROOM 9. '/3 ':. 3-8-Vg .44/ : o 4 PROVIDE JUNCTION BOX FOR OWNER SIONAL '+0 MDP' MDP -10 .CTOAC M P` CAMERA. PROVIDE 1PROVIDED, OWNER I C FROM JUNCTION III s I -roAc -1 ENGINEER'S STAMP -�,I - - - - - - - - - - - - - - - - - - - - - - - - - - - - BOX BACK TO IT ROOM 9. r MDP-1 • G1 • G1 • G1 • G1 - MAIN EQUIPMENT 1' IjI MDP-26 0 IT 1 1 1 1 5 PROVIDE 20A(2WG)TO JUNCTION BOX 551 N Frontage Rd W, Vali, ROOM(ER)/IDF. 4II MDP-3 /II FOR HAND DRYER. COORDINATE EXACT CO 81657 Al MDP g IN-GRADE HAND HOLE. LOCATION WITH ARCHITECT PRIOR TO © 51 (2)4"C.FROM ROUGH-IN. 10 18"W X 24"L-DEPTH AS r—� � GYMNASTICS BUILDING, REQ'D.PROVIDE TRAFFIC I m BELOW GRADE. 6 PROVIDE 1"C.BACK TO IT ROOM FOR MDP-5 RATED COVER. RE:E1.00 SITE PLAN wQ - � - 1 1 ALE FOR CONTINUATION. FUTUR CASH/CARD MACHINE. w1 7 CIRCUIT FIXTURE TO OUTPUT BREAKER#1 ® MDP MDP 6 IN THE CENTRAL INVERTER LOCATED IN Ei 0 " MDP-5i WP MECHANICAL 5. • •S•E O O 8 PROVIDE LITHONIA#EAC FTT 1500 120/120 1 0 MDP 7 0 1E 0 1E 0 1E 0 1E 0B3 CENTRAL LIGHTING INVERTER OR - y EQUIVALENT FOR EMERGENCY LIGHT O - - - - - - - - - - - - - - - - - - - - - - - - + - - - �((d3 - - FIXTURES. � AO II W 11777df7T7]MDPE 1 a �� c...) 181 II 1 ® O7 ( / 1 9 CIRCUIT FIXTURE TO OUTPUT BREAKER#2 ====�11 v MDP_ © 00 • MECHANICAL 4t$ IN THE R5 L INVERTER LOCATED IN Si = 11- Si S1E 0 MDP-9 G1E G1 0 -==�I�===7 ml , 1 ===Th OS 1111111111P-1111111111P- MDP 'S� �1 C ====JIB=-� -10 TO'MDP-2 (in V-...FEMALE - w1 1 DETECTOR 7___ - .•. 7 LOOP,TYP. 0) (53EM8P ® r - - 1OI r - - J ■ — I L — — Ni O 3 X1 WP WP MDP I IMDP-13 G1• I • () - W1E -18 ®X1 J n I �MDP-13 `�' �� 4 1 p Li (13 -1 1 1"C.,TYPICAL. 1 0 - - I -IlCL I 6 MDP I II II II II II II II II I MDP ' Fy W1E -20 0 G1E G1 / / LJIJ1-LJIJ1_Lli r - - T NEI - , 0 0 0 0-I w1E� ELECTRICAL PLAN LEVEL 1 I II 11 II III I 11S. L J L _ _ J 01 LII 11 JIII IIIS___--l V = SCALE: 1/8" = 1'-0" �W2E -1-0O O 0 W 13) x- E u) a) J W III CD 0 0 0 4 0 6 0 8 9 1 o W J o J -1- J Q U 73 c MDP-15 A 1 1 All© O�MDP MDP-15� P WP� EF M��� 0 O U) MDF-47 25,27 MDP-49 MDP-51 I- U w J 13) �/ I w Q B MDP • • • • -14 1 G1 G1 G1 G1 O ■ N - N O .N W ,- o X1 _ O O O O co v L — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — o W •G1E /G1E •G1E %G1E I . _ Z t =-,,71 coo 0 W1E MDP 1 I� 0 E • • 18 11 / �0 - d — G1 G1 0 5ci) ti W o m N = (I TO'MDP-4'S� 1"C 3 v O Q a _1 `----�'- : DETECTOR m , , , _ LOOP,TYP. z , , -- - - \ OU , o - r as - -I . - MDP O O CD W WP WP ® IR W1E -18 '■' Q G1 I I 1 4 qp MDP-15 ISI MDP-15 _ vito�iii 1 - ii — — I — I — – — — — 1 1 — – — — — — — 1 1 — — — — �� Imo — — — — D N 0_ W2E 1'I MDP-15 I •2 o 9 WP w O OI C a) W L II G1E j )it 6 �M0DP fl,J I I:1 L'I I. H , -' w O I / I I- "1. I' I, I ,1 ,1,-I 11 - 'MDPICC 71: -y`.W1E I I, 1 1 '1 ,I -1 '1- I' 1 • co 1"C.,TYPICAL. / 20 C_ I I_ l _I' i "I I_ 1 1 ,l I •' = rn _ _ / L I 1 '1- I .I- I' l'-1 'I •I . - c o �� 1 I I-'1 -i' 1' 1_,I - W1E-/ N _J k L — — JI I- 1 l'', 1f 1' I Q Ta L — — J •' 0 o O O I1Li CD fa _ o 0) 1." r) cK ELECTRICAL PLAN LEVEL 2CD c 2 _ _ CD z E c U 0 2 SCALE: 1/8" = 1'-0" Ce LLI `° — — O BUOONOOOOKS c d Q t O a) - systems fulfMed a) a Cr) o A 303.278.3820 wwwbgbuildingworks corn L N Project No.9864.00 Copyright 2017 • i o P.6 cAALBUQUERQUEIAVON IDENVER IFORT COLLINS Q O .slti OF 10 „r„:074.0000.44, i..;*.15 M. HEAT TRACE NOTES: , shop 1. PROVIDE 12W/FT, 208 VOLT ELECTRICAL, 06/06/18 SELF REGULATING,HEATING CABLE IN ALL GUTTERS AND DOWNSPOUTS.ELECTRIC HEATING CABLE SHALL BE UL AND CSA LISTED SPECIFICALLY AS ELECTRIC ROOF AND GUTTER DE-ICING AND SNOWMELTING EQUIPMENT.CABLE BE QUALIFIED FOR PROLONGED UV EXPOSURETO THE SUN PER IEEE 0 :2 14 5\ 60 i-8 9 1- 10 515-1997 AND TO WITHSTAND CONTINUOUS SUBMERSION IN WATER PER \ 0 IEEE 515.1-1997. PROVIDE ALL ELECTRICAL CONNECTION KITS,SUPPORTS, 1.. DETECTOR DOWNSPOUT HANGERS,CONTROLS,AND TO'MDP-6'S,... 4- 4 LOOP,TYP. OTHER APPERTENANCES FOR A COMPLETEAND OPERABLE SYSTEM IN w r OL _ _ d im O r , REOCOMIENDAT OINS MANUFACTURER'S > 2. OVERCURRENT PROTECTION FOR LIJ ELECTRIC HEATING CABLE CIRCUITS W2 10 �w2E SHALL BE 30-mA-TRIP GROUND FAULT �1 I I 1— __— I \ — —II A Q 6 ID MDP-17 b (i) TYPE CIRCUIT BREAKERS. G1 I I I G1 MDP O WP MDP 0 MDP-17 WP MDP-17 WP U O I 1 irN 29,31 -33,35 3. CONTRACTOR SHALL PROVIDE COMPLETE AND OPERABLE CONTROL SYSTEM. 1"C.,TYPICAL. I SYSTEM SHALL CONSIST OF AMBIENT +�r+■•""+• THERMOSTAT AND MOISTURE SENSOR ,i' To 0 t/c,."- I I WITH CONTACTOR(S). �,+,o,, S" ''•0:9<;\ ry._ 4. CONTRACTOR SHALL SUBMIT SHOP DRAWING SUBMITTAL 2 15 L G1 EEQUPMENT,CONTROSI CONTACTORS '• -a .., • ct Q. SHEETS SHALL BE MARKED INDICATING ` """' Cs\ �' AND ACCESSORY DATA SHEETS.DATA '��oF=. rYy� /..._0. THE ACTUAL MODEL,VOLTAGE, RATINGS, ---...,,.0,4'l SIOf,AL +�'� AND ACCESSORIES BEING PROPOSED TO �F" + iB BE PROVIDED. SHOP DRAWING SHALL ENGINEER'SSTAMP INCLUDE LAYOUT PLAN INDICATING 10 10 % 10 10 �� ZONING,CONTROL INTENT,AND G1E G1E G1E G1E ESTIMATED CIRCUIT LENGHTS.PARTIAL 551 N Frontage Rd W, Vail, OR INCOMPLETE SUBMITTALS WILL NOT BE ACCEPTED. CO 81657 5. ACTUAL INSTALLED HEAT TRACE CIRCUIT X1 LENGTH MAY VARY FROM DESIGN OR I PLANNED FOR CIRCUIT LENGTHS. * CONTRACTOR SHALL MEASURE AND RECORD ACTUAL CIRCUIT LENGTHS AND PROVIDE THE CIRCUIT LENGTHS AS PART OF TEST REPORTS. CIRCUIT LENGTH SHALL NOT EXCEED THE MANUFACTURER'S RECOMMENDED LENGTH FOR THE OVERCURRENT MDP PROTECTION RATING.CONTACT -16 \ ARCHITECT/ENGINEER IF ACTUAL \ G1 G1 G1 G1 INSTALLED ELECTRIC HEATING CABLE C LENGTHS EXCEED THE MANUFACTURER'S AO r V//TV//A - RECOMMENDED LENGTH FOR THE � W1E MDPT OVERCURRENT PROTECTION RATING. '18,1 ___ 6. CONTRACTOR SHALL PROVIDE ALL _ - TESTING AND FIELD QUALITY CONTROL Si ==--- MEASURES RECOMMENDED BY AO _ O I MANUFACTER. INCLUDING, BUT NOT LIMITED TO, MEGER TEST ALL UR) HEATING CABLE CIRCUITS.AFTERCTRIC INSTALLATION ALL HEATING CABLE 01) - _ CIRCUITS SHALL BE TESTED WITH A 2500 VDC MEGOHMMETER, INSULATION C RESISTANCE FROM THE CONDUCTORS TO N . x1 THE SHIELD SHALL BE GREATER THAN MDP 1000 MEGOHMS.CONTRACTOR SHALL '";E,z; WP O ® RECORD ALL TESTS AND PROVIDE TEST MDP-17 WP Iv�DP-17 —`,�)� - III I 1 — _ REPORTS TO ARCHITECT/ENGINEER, L. — — — D PRIOR TO PROJECT CLOSEOUT OR FINAL (13 I PUNCH REQUESTS,AS PART OF THE PROJECT CLOSEOUT DOCUMENTS. O. MDP -20 r ,1 I I.1 L'1 1„1,,I: 1 . 1- 1. 1. 1. 1 ,1 ,1-1 1 -i - MOPS POWER NOTES: F. W1E 1 ,-b 1. 1 -1 -1 ,1 -I,'1- 1 I - -20 I 'I_ _I'1• "I 1_ I 1_,1 •-I- •- L1 'l- �- �' 'I I W1E 1. ELECTRICAL CONDUIT SHALL BE ROUTED I 1-'I -'1 1" 11,':1_1 TIGHT TO STRUCTURE BACK. 1 l I - 1 ,1 -1 I 1: I I I- 1. I 1, 1 ,1 -1H 1 -r I , -li 2. G1' FIXTURES SHALL BE CONTROLLED VIA ELECTRICAL PLAN LEVEL 3 L — INTEGRAL MOTIONSENSOR.WHEN ai SCALE: 1/8" = 1'-0" ` J MOTION IS DETECTED,FIXTURE , j. }, BRIGHTNESSGOESTO 1 0% WHEN NO C MOTION IS DETECTED FOR 30 MINUTES, FIXTURE AUTOMATICALLY SETBACK TO 50%. 3. EXTERIOR MOUNTED FIXTURES SHALL BE co E CONTROLLED VIA INTEGRAL PHOTOCELL. ' ^ 4. 'SP2'FIXTURES SHALL BE CONTROLLED vJ VIA EXTERIOR LIGHTING CONTROL PANEL J WITH ASTRONOMIC TIME-CLOCK AND W III PHOTOCELL. RE:DIAGRAM D/E4.01 FOR MORE INFORMATION. > CD 0 0 05. ALL EXIT SIGNS AND EGRESS FIXTURES EkII 4 5 6 � EIII: 10 SHALL BE CIRCUITED TO LOCAL LIGHTING LLI CIRCUIT. .1O C I I 0 FLAG NOTES: _ J 1"C DETECTOR 1 AUTO-GATE, PROVIDE CONDUITS WITH TO'MDP-8V-, ' /LOOP, PULL STRING FOR POWER DATA — Lr! 4:::( CONNECTION.COORDINATE JUNCTION 0 = ----...1111111111111111111111111111111111111111111111 - MDP-19 r 1 �� r BOX INSTALLATION LOCATION WITH MANUFACTURER'S PRODUCT DATA, MDP 1 = r11� _ 0 — _ _ `/� C� � A PLANS,AND INSTRUCTIONAL MANUAL. r{� -37,9 10 SP �' MDP-19 SP ' \V SP2 I NJ I 2 PROVIDE SUNMODULE PLUS SW 290 H U) 8 I PHOTOVOLTAIC PANEL OR EQUIVALENT. 1"C.,TYPICAL. I I PHOTOVOLTAIC PANELS SHALL BE U JO MOUNTED AT AN ANGLE.COORDINATE 22D24 I I EXACTLOCATIONWITH ARCHITECT PRIOR w I TO ROUGH-IN.PROVIDE ALL NECESSARY 11 I MOUNTING HARDWARE TO MOUNT \ I I PHOTOVOLTAIC PANELS AT AN ANGLE. W 1 —) I- — — 1 3 PROVIDE SUNMODULE PLUS SW 290 r PHOTOVOLTAIC PANEL OR EQUIVALENT. L _ _ J 0 — — PHOTOVOLTAIC PANELS SHALL BE /) MOUNTED FLAT TO WALL.COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN.PROVIDE ALL NECESSARY MOUNTING HARDWARE TO MOUNT THE PHOTOVOLTAIC PANELS FLATTO WALL. CSI 4 PROVIDE 40A(2WG)TO JUNCTION BOX 0 FOR ELECTRIC CAR CHARGER. PROVIDE N CAT6 CABLE TO CHARGING STATION. ao E, WN C" .2 N- ! CC 5 PROVIDE JUNCTION BOX FOR OWNER PROVIDED, OWNER INSTALLED CCTV CAMERA. MOUNT AT 90"AFF.PROVIDE 1"C. FROM JUNCTION BOX BACK TO IT ROOM 9. d 6 PROVIDE JUNCTION BOX FOR OWNER PROVIDED, OWNER INSTALLED CCTV CAMERA. PROVIDE 1"C. FROM JUNCTION BOX BACK TO IT ROOM 9. _� ti -c 1 vzz ��d, - 7 PROVIDE WEATHERPROOF JUNCTION BOX CO o W z .E W1E MDP EM1 N ti co 0 FOR FUTURE HEAT TRACE ROUTED IN c 18 • STORM DRAIN PIPING.REFER TO HEAT 0 :i—, of W = O TRACE NOTES THIS SHEET FOR MORE U rn y ca INFOMRATION. REFERTO DIAGRAM C ON H � I SHEET E4.01 FOR HEAT TRACE ROUTING. m N I == 8 PROVIDE 1"C.BACK TO IT ROOM FOR m cf) , , H _==J FUTURCASH/CARD MACHINE. cn OO , Lu - U9 PROVIDE WEATHERPROOF JUNCTION BOX FOR FUTURE HEAT TRACE. REFER TO Co — X3 HEAT TRACE NOTES THIS SHEET FOR IR LJJ OMDP I MDP O Map SP2 O7 ti�p 28 3P0 SP2 05 X3 MORE INFOMRATION. CO w 0 W1E 18 28,3 SP2 oi MDP a r"T I = Wp Q-28,30 • Q 25,30 Wp EM1 3 a, Y -28,30 OQ� —_ MDP-19 Y Oo- o MDP-19 � � D L I10 CIRCUIT FIXTURE TO OUTPUT BREAKER#3 Co c° G G G G G G G o IN THE CENTRAL INVERTER LOCATED INI p co MDP MECHANICAL 5. 'C o iti co ©,TYPICAL OF 27 -28,30 a) Lu MDP s ,1 I l.I C '1 I"I. I - 11 SP2 FIXTURE SHALL BE CONTROLLED VIA w 0 -20 1• 1- 1' 1, 1, 1 ,1 ,1,-1 1 1 MDP 7 EXTERIOR LIGHTING CONTROL PANEL 0) u) W1E 1, 1 1 1 "I -1• ,1 -1 '1-•1' 1 • - —20' m �I LOCATED IN ROOM'MECHANICAL 5'. 03 I1. 1 .1' 1. 1 1. I 1_,1 1_' - CF9 I 1- 1 .1- C 1 1 'I i EXTERIOR LIGHTING CONTROL PANEL cp W1E_i SHALL HAVEASTRONOMIC TIME-CLOCK a N '1 1 7' 6, 1 1' 1 ii -, AND PHOTOCELL. a I 1_ I 1_ I ,I I'I I'' -, I 1 �i ,1 -i I,-1 r - - c- CD o I I I,- _ 12 PROVIDE WEATHERPROOF JUNCTION BOX c o _1 FOR HEAT TRACE. REFER TO HEAT TRACE L 8 CC i©,TYPICAL OF 12 NOTES THIS SHEET FOR MORE 1. 1 INFOMRATION. C c) ELECTRICAL PLAN LEVEL 4 cy' o Q SCALE: 1/8" = 1'-0" Ce 6 (0 N � �� n�^n` L 0 O :0 BU O LJ NGLIV ORIJUS V 2 • co systems fulfMed a) a m o303.278.3820 wwwbgbuildingworks corn .. D N2 Project No.9864.00 Copyright 2017 i o U c ALBUQUERQUE I AVON I DENVER I FORT COLLINS Q O OF k..,,,:01:4144i4, 4t;40(..15 SHORT CIRCUIT/ VOLTAGE DROP CALCULATION SUMMARY WIRING SCHEDULE COPPER SERVICE WIRINGSCHEDULE FLAG NOTES: poplai F" I S C (2 W G) (3W G) (4WG) 06/06/18 z VOLTAGE/ LENGTH COPPER/ WIRE #OF FEEDER TOTAL AMPS AMPS (4W) GROUNDING ELECTRODE CONDUCTOR O TAG PHASE (FT) ALUMINUM CONDUIT SIZE SETS VOLTAGE VOLTAGE AVAILABLE Isc(FAULT) 10,2 WIRE,GROUND 10,3 WIRE,GROUND OR 30,3 WIRE,GROUND 30,4 WIRE,GROUND ala,4 WIRE W.P. M.F. C.E.C. G.RING G.ROD a DROP(%) DROP(%) UPSTREAM Fl DISCONNECT 208V,30 100 A N 500 4 0.2% 0.2% 20 (2#12&1#12 G)3/4"C (3#12&1#12 G)3/4"C (4#12&1#12 G)3/4"C 1200 4[(4-500 KCMIL)31/2"C] #3/0 CU #3/0 CU #3/0 CU #3/0 CU #6 CU 59,600 37,720** F2 MDP 208V,30 15 A N 500 4 0.0% 0.3% 21,544 20,887 30 (2#10&1#10 G)3/4"C (3#10&1#10 G)3/4"C (4#10&1#10 G)3/4"C CONDUIT SIZES ARE BASED ON NEC TABLE4(RNC)AND TABLE5(THHN INSULATION). *PER THE UTILITY,THE MAXIMUM AVAILABLE(SYMMETRICAL)FAULT AT THE SECONDARY SIDE OF THE SERVICE TRANSFORMER IS 59,600 AMPS, 40 ABBREVIATIONS: W.P.-WATER PIPE; M.F.-METAL FRAME OR STRUCTURE; C.E.C.-CONCRETE ENCASED ELECTRODE; ASSUMING A 300 KVA TRANSFORMER.SHORT CIRCUIT CALCULATIONS ARE FURNISHED FOR ALL FAULT LEVELS ABOVE 10,000 AMPS @ 208 VOLT.ANY (2#8&1#10 G)3/4"C (3#8&1#10 G)3/4"C (4#8&1#10 G)1"C G.RING.-GROUND RING; G.ROD-GROUND ROD,PIPE OR PLATE ELECTRODE FAULT CURRENT BELOW THIS LEVEL IS CONSIDERED SAFE FOR THE ELECTRICAL SYSTEM TO CLEAR OR EQUIPMENT IS BUILT TO WITHSTAND THIS 50 (2#6&1#10 G)3/4"C (3#6&1#10 G)1"C (4#6&1#10 G)1"C LEVEL OF FAULT SAFELY. **LET-THRU CURRENT OF BUSSMANN#KRP-C_SP 1200 AMP FUSE IS 21,544 AMPS. 60 (2#4&1#10 G)1"C (3#4&1#10 G)1"C (4#4&1#10 G)1 1/4"C WIRING SCHEDULE - 70 (2#4&1#8 G)1"C (3#4&1#8 G)1 1/4"C (4#4&1#8 G)1 1/4"C 80 (2#2&1#8 G)1"C ALUMINUM (3#2&1#8 G)1 1/4"C (4#2&1#8 G)1 1/2"C LLI 90 (2#2&1#8 G)1"C (3#2&1#8 G)1 1/4"C (4#2&1#8 G)1 1/2"CAMPS (4WG) 30,4 WIRE,GROUND > 100 (2#1&1#8 G)1 1/4"C (3#1&1#8 G)1 1/2"C (4#1&1#8 G)1 1/2"C CONDUCTOR SIZES ARE BASED ON 60°TERMINATIONS LESS THAN 100A AND 75°TERMINATIONS GREATER THAN 100A 200 (4-250 KCMIL&1#4 G)3"C A' CONDUIT SIZES ARE BASED ON NEC TABLE 4(RNC)AND TABLE 5(THHN INSULATION). 1200 4[(4-500 KCMIL&1-250 KCMIL G)31/2"C] I: CONDUCTOR SIZES ARE BASED ON 75°TERMINATIONS. 0 w CONDUIT SIZES ARE BASED ON NEC TABLE 4)RNC)AND TABLE 5 U (THHN INSULATION). it+ �►D L/C.. \ t2,- .'• d' --- 4./ " I-% • • 15 E • • LEVEL4 •/3 '• 3-8r1�:" 41./ t `FABS•••...••••••'A,c,\ i''1 PON AL S *04 EN GINE ER'SSTAMP 551 N Frontage Rd W, Vail, CO 81657 TO PV SOLAR ARRAY-(1)STRING a) OF 15 PANELSAND(2)STRINGS OF 12 PANELS.TOTAL 11.31kW PHOTOVOLTAIC PANEL GRID-TIED SYSTEM. LEVEL 3 U —I-0 U) 0) C ■ MAIN SERVICE DISCONNECT UTILITY CT CABINET HEAVY DUTY SERVICE RATED FUSED DISCONNECT 1. 1200 AMP,31),600V RATED. UTILITY METER i NEMA 3R ENCLOSURE. CU PROVIDE BUSSMANN#KRP-C_SP � 1200A FUSE. O M C 0_ Q 1 TPV INVERTER.PROVIDE SOLAREDGE#SE14.4KUS OR EQUIVALENT. n S LEVEL 2 v /�{� `v . < -1-• 1200A(4W)AL c 1200A(4WG)AL 0n' IW SPD W E DC /1-. 40/3 MDP-MAIN DISTRIBUTION PANEL n 13) 40A(4WG)CU AC Z .1 _ 1200 AMP,208Y/120V,31) I LIJ N W a)G PROVIDE(2)3 1/2"C TO STUB UP C POINT IDENTIFIED ONI 0 O PROPOSED ELECTRICAL SITE " PLAN FOR FUTURE EXPANSION. GROUNDING ELECTRODE 14 e I CONDUCTORS SIZED PER SERVICE WIRING SCHEDULE ' LEVEL 1 V BLDG.STEEL I.A.W. c N.E.C.250-52(A)(2) WATER SERVICE I.A.W. N.E.C.250-52(A)(1) F- CO 20 L.F. ' ENCASED IN MID IN MIN.2" V OF CONCRETE. 7.3 I.A.W.N.E.C. ' I I 250-52(A)(3) I.i.l J W/� W I/ 1 Electrical One-Line Diagram SCALE: NONE 0 0 . NrNm O 2 W � N 'g N `� O o cu O -&-5- K d c .. ��rrR� VJ O 2. '♦ ) I� z m coo 6 W fV (c) 0 O E .co 0 .5 O J W � 0 w U) az 1 m Q 0 �N = o M ,J M (3 <.O W 00 -2O z , w U Uco -cp L Lu s'-' coIR CO -0 rf6 LO LLJ V C) S_ ._ N L(n Il Q 0 U) L W a--. W cK rn © w © /r (C co E x co C 0 1.t.. c3 2 c7 c J I..L J L Q Co I 0 J 0 .5 •L 9- ca Lir ^` 0 0 cK CD W O C c U U ^' w0 Oci IY ri _cr 66 : igi 0a BUOLDNGW0 RKS a) ,- systems fulfMed a) _, a) E) 303.278.3820 wwwbgbuildingworks corn L N A Project No.9864.00 Copyright 2017 . i o o (i ALBUQUERQUEIAVONIDENVERIFORTCOLLINS Q O *Alti OF go AN:4044.44, .th;lial M. FINISH CEILING 01 "Qin E-Q 9I LEVEL 41 -- D, 06/06/18 Z7 —--—+ c 7(._ 1 E-Q • BO t EO . 4 1 /P1 , X1,\: 1 BEAM 1 TYPE"G1"PARKING GARAGE t FIXTURE MOUNTED BELOW LL BOTTOM OF DECK PLUMBING&MECHANICAL EQUIPMENT. w 1= WALL MT J-BOX/ w PULL BOX,TYP. w , z= 0 LEVELS \ ALIGN POWER-BASED DEVICES Q Q DOOR WINDOW (RECEPTACLES,SWITCHES, J H W ETC.)VERTICALLY. DO NOT U§ / VERTICALLY ALIGN POWER AND z I— COMMUNICATION DEVICES g SIMULTANEOUSLY. 3/4"C. 0 w LIGHTING I \ TYPICAL. �J r 1 r�J) CONTROL J qN (1)4"C.0 i CI io L/ 6"VIN 2 �'�r O i� C, �'. �MI�N� I M X ` O,'. ,•S., '' 1 r BACK SPLASH PARKING GARAGE LIGHTING DIAGRAM �'�`' �` `" :� (� LEVEL 2 , , L _ ` J COUNTERTOP Q ` 1� ; EQ-0"-"0—EQ I 1 0 J NO SCALE (73 1 c 1C .... 0 .... .... 4.0 ,. -....--61s,-........... \ ... 1 1 ___ - 11GA STEEL POLE. _`sioNAL 0\, 0 RECEPTACLE0 _0 0 , ______ HANDHOLE COVER. I _______ I J-BOX FOR LOW ENGINEER'SSTAMP y I 1 VOLTAGE DEVICE, GROUND LUG. I I TYPICAL. COMMUNICATIONS 1 HAND HOLE. 551 N Frontage Rd W, Vail, FINISH FLOOR BASE COVER. / CO 81657 NOTES: ,-, IT ROOM 1(2)4"C. LEVEL 1 : 1 : OFFSET COMMUNICATION 7 ( 7 1 DEVICES FROM POWER I 1. IF ALIGNMENT OF DEVICES INDICATED HERE IS IN DEVICES TO EITHERiHI ` CONFLICT WITH ADA REQUIREMENTS DUE TO TO GYMNASTICS OPPOSITE SIDE OF STUD INSTALLATION DETAIL,ADA DIMENSIONS SHALL BAY,ORADJACENTSTUD ° .� I r° �° I i° w 5 BUILDING. GOVERN. BAY. m IA ° 2 REFERENCE ARCHITECTURAL INTERIOR TYPICAL DEVICE ALIGNMENTS - 11 ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ° ° ELEVATIONS SHALL SUPERCEDE LOCATIONS SCALE:NONE - ° VI- SHOWN HERE,UNLESS LOCATIONS SHOWN ON { ° III INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. ' °�°�ma° ° CONDUIT&WIRING. COMMUNICATIONS PATHWAYS RISER1,1 �a° DIAGRAM SCALE: 1/8" = 1'-0" }0 a9 ° d v 8 FINISH CEILING GROUND PLATE(COPPER)OR ° 10-TURNS OF#4 BARE COPPER WIRE. Al TOP OF DEIVCE • inI OC I WALL MOUNT M N e\° \ ° POLE BASE DIAGRAM 9'-0"CEILING <1_1> MINIMUM,TOP OF DEVICE IC NO SCALE ® ® 24"DIA. / O 8'-0"CEILING BOND TO BUILDING BOTTOM OF DEIVCE 8 4 4 STEEL,TYPICAL. 1 1 1 2ND LEVEL TOB OF CABINET (13 TOB OF CABINET A FACP 1 111 A ❑-' C CB E I LI 1 1 1 1 1 ' BOND TO GROUNDING BUS IN 2X TOB OF CABINET TOB OF CABINET I ' ELECTRICAL PANEL.FIELD M \ ATS TC A ANN COORDINATE WORK WITH I WATERPROOF ELECTRICAL CONTRACTOR. Si 96" J-BOX. 1 1 HEAT TRACE \1_ 1 Al 9.0" 1 1 1 TOP OF DEVICE S LV D • O M•X t TOP OF DEVICE F E �IIIIIIVIII C 78" 78" T/////"/ IT ROOMI 1ST LEVEL 8n" MN 2 E BONDING CONDUCTOR FOR 8 I #2/OAWG IN AWG NOTES: < (I) 1. IF MOUNTING HEIGHT OF DEVICES INDICATED w' 48" q OF DEVICE 48" HERE IS IN CONFLICT WITH ADA rL.Y` a REQUIREMENTS DUE TO INSTALLATION DETAIL,ADA DIMENSIONS SHALL GOVERN. I� 2. REFERENCEARCHITECTURAL IONSSHWINN ON TELECOMMUNICATIONS GROUNDING & Q a) 18�� ELEVATIONS.LOCATIONS SHOWN ON FINISH FLOOR, ' ' ' t ' S NS INTERIOR ELEVATIONS SUPERCEDE LOCATIONS SHOWN HERE,SH UNLESS BONDING DIAGRAM A G RA M LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. ROOF DRAIN HEAT TRACE DIAGRAM 0NO SCALE SCALE: 1/8" = 1'-0" 0 ELECTRICAL DEVICES FIRE ALARM DEVICES C VI < %I if TYPICAL DEVICE MOUNTING HEIGHTS U c PHOTOCELL 527) SCALE:NONE MOUNTED ON ROOF 12 CU Ila FACING NORTH. H (f) SYSTEM U CLOCK N W TC = W 1 TYPICAL #6 AWG INSULATED GND — I I TO EXTERIOR LIGHTS COND.TO COMM.EQUIP. II --, - , I I #2/0 AWG INSULATED — GROUNDING NOTES: GND COND.FROM TBB �17 - 1. ALL GROUND CONNECTIONS SHALL BE MADE WITH HEAVY DUTY 2-HOLE COMPRESSION LUGS WITH MOUNTING / 0 1 1 0 e 0 O ® 0 0 I 1 0 0 STAINLESS STEEL SCREWS AND LOCKING NUTS,TWO BRACKET,TYPICAL. o o I o e o 0 e 0 0 l o o SCREWS&NUTS PER LUG. GROUNDING /...-. �vO_ i /�O_ /. 2. PROVIDE GROUNDING BUSBARS IN ALL o 120V BUSBAR,TYPICAL. o o • 0 0 0 0 0 o o COMMUNICATION CLOSETS. BOND MAIN BUSBAR • DOUGLAS LIGHTING o 0 0 0 0 0 0 0 0 1 0 0 (TMGB)TO BUILDING MAIN ELECTRICAL SERVICE CONTROL PANEL GROUND WITH#2/0 AWG INSULATED STRANDED INSULATOR,TYPICAL. o o 2 #WPAK-33524-S O Q° COPPER CONDUCTOR AND#2/OBETWEEN BUS BARS. r , .N GROUNDING TO BUILDING STRUCTURE,CONDUITS, W co o TWO-HOLE UTILITY PIPING,OR ELECTRICAL SUB-PANELS IN LIEU COMPRESSION LUGS, FRONT EXTERIOR LIGHTING CONTROL DIAGRAM TYPICAL. ELEVATION SEOF VICEGRINGTOBUA ACCEPING TAN BLE.SERVICEGROUNDJI6T ACCEPTABLE. NO SCALE TO TELECOMMUNICATIONS CONNECT TO: 3. BONDING CONDUCTOR BETWEEN TMGB AND END O #2/0 ❑ BUILDING STEEL OR BUSBAR SHALL BE CONTINUOUS.PROVIDE C TYPE BONDING BACKBONE(TBB). ❑ CONDUIT RISER D COMPRESSION TAPS TO FEED INTERMEDIATE TO BONDING CONDUCTOR #2/0 4.-- ❑ EACH DATA RACK BUSBARS. FOR TELECOMMUNICATIONS � (BCT). I" 4. BOND EACH CONDUIT IN ALL COMMUNICATIONS p� Z ROOMS WITH#6 AWG INSULATED STRANDED COPPER e e O GROUNDING CONDUCTOR TO GROUND BUSBAR. ' AP 0 0 0 0 0 #6 AWG, O W 0 0 0 0 o TYPICAL. - z U e e O ROUTE CONDUCTOR IN CABLE RUNWAY TO ("Ni r•--- ,_,a) D 0 E ;r 0° 0° GROUNDING BUSBAR.CO p J v S 5. BOND CABLE TRAYAND RUNWAY WITH#6 AWG �I ' 0 0 0 0 0 0 0 0 0 0 0 7=3 Q o 0 0 0 0 0 0 0 0 0 0 0 INSULATED STRANDED COPPER GROUNDING ? H (0 12.1 CONDUCTOR TO GROUNDING BUSBAR. CV = v o VARIES: 12"-20" cfl 0-3 J _ m co Cfl , 1- TYPICAL TMGB 0O Z l'' -2 0w U cv („-- _c, cr) LU caIR COMMUNICATIONS BONDING DIAGRAM CO -0 ) L SCALE: 1/8" = 1,-0" L o_ a L w w CD rI cn w V co �_ 1- C 0 , aa) N J I..L J 0- Q U o J C E 0 a) Lir ^` O i ct L7 Wj�` c U U 2 ^' w0 Oci IY ri c d Q U O a) ,- systems fulH Hed CD o m o A 303.278.3820 wwwbgbuildingworks corn L • N Project No.9864.00 Copyright 2017 . i o U cAALBUQUERQUEIAVONIDENVERIFORTCOLLINS Q O