HomeMy WebLinkAboutapproved plans_3.pdf 7..."...--;-.77 -- ;----,,,,,,Te _ .,,., ., , _ , . ____ ,,, c,,,i „,,,,s, , OFF14 4 LODGE AT LIONSHEAD UNIT # 11 PERMIT SET --_04. 10.2 418 GENERAL NOTES: ' GRAPHIC STANDARDS ! PROJECT TEAM PROJECT SUMMARY Sheet#, Sheet Name — �� _ —_ CODE: OWNER 2015 5000 !COVER SHEET i 1. DO NOT SCALE DRAWINGS. FELIPE ESTEVE IBC G J j 'EXTERIOR ELEVATION IDENTIFICATION WINDOW IDENTIFICATION ARCHITECTURAL 7 I ? I AUXI ifLOORPLANS 2. VERIFY ALL DIMENSIONS,CONDITIONS,AND UTILITY LOCATIONS ZONING: PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS, I DRAVANG NUMBER O I ? WINDOW TYPE { NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE aa.ol SHEET NUMBER ( Y , HIGH DENSITY MULTIPLE FAMILY DISTRICT DOCUMENTS IMMEDIATELY. ARCHITECT INTERIOR ELEVATION IDENTIFICATION KEYNOTE IDENTIFICATION 1 RHYdEABARCHITECTS ( T 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY 710 WEST UONSHEAD CIRCLE,UNIT A ';,I—--1' { .: } OCCUPANCY CLASSIFICATION: RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS ? DRAWING NUMBER i ( vaL co asos7 1 O 1 BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR ? ? ? { ! i P:970.477.2990 TYPE R 2 REVIEWED �ARG ( AREAS. ( ?t^'-NOTE NUMBER F:970.477.2985 ( . ? SHEET NUMBER -..a I a� CCE) 4. PLAN DIMENSIONS ARE TO FACE OF STUD,CENTERLINE OF DETAIL IDENTIFICATION REVISION IDENTIFICATION i CONTRACTOR CONSTRUCTION CLASSIFICATION: COMPLIANCE' STEEL,TIMBER,STUD COLUMNS,OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE j ! `DRAWING NUMBER ^ TYPE II I BzG � TO TOP OF CONCRETE,TOP OF PLYWOOD,OR TOP OF WALL L. \- REVISION NUMBER b PLATES OR BEAMS UNLESS OTHERWISE NOTED. a9.Ds SHEET NUMEER OCCUPANCY SEPERATION? --REVISION DESCRIPTIONj " G 1 1 HOURBy: 5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND ELECTRICAL (GARAGEI RESIDENCE) — .._. �,_ _.„ .�,<__ CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING 1 s . 1 HOUR(MECH./RESIDENCE) L 2 Ls AND WALL MOUNTED FIXTURES,TOILETS,TOILET ACCESSORIES, ( S+HOUR(RESIDENCE/CORRIDOR) O CABINETRY,COUNTERTOPS,SHELVES,CLOSET RODS AND FALSE ®° �x'_' " "" WALL SECTION IDENTIFICATION BEAMS. SRC IONS MATERIAL 1 HOUR(RESIDENCE/RESIDENCE) - 6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO [ I DRAWING NUMBER 2 HOUR(SHAFT CONSTRUCTION) RECEIVED DOOR SCHEDULE FOR DOOR TYPES. Y A5.11 SHEET NUMBER : i. _- -� II CONCRETE i _� 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO ""` I I �-+ WINDOW SCHEDULE FOR WINDOW TYPES. i I I - til I t✓I N 1 TY MAP - fid 1 ; y2018 "-- ii j UNDISTURBED OR 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO ! 1=-`I: ' COMPACTED EARTHS I FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH i 1 BUILDING SECTION IDENTIFICATION t I _.,_. '' - ', - �'e , { ARCHITECT WHEN DIVERTING FROM DRAWINGS. y t--�j —1 i POROUSFiLI r, " mo"""w"` ` ' .. ` ` Vail : t 1 V-----DRAVONG NUMBER TOWN 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS 1 I A5 01' SHEET NUMBER I r NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY 1 I �\� ii ": I ASPECT OF THE PROJECT,THEY SHALL IMMEDIATELY NOTIFY THE 1 ! /1 STEEL E1Llonshead:Cir .. E Lio head«Gir t ( rte 7 s V ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT ; ; ��lr; SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. i t - ', ` L Jewlsh CommunIty I 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR 17-7;7. .4 ALUMINUM R 62nter " -. ,•,} SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS ENLARGED DETAIL IDENTIFICATION _' s. * AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE I I [ h- .. AREA OF DRAWING TO 7 'tri 1 " INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL MASONRY•BRICK I �Odge at dp ' RESIDENTIAL CODE. COMPLIANCE IS MANDATORY. THE I h BEEN ARCED w _ $179 .1 tkr CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES 1 j i;: -- NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN UBC AND �iy T DRAWING NUMBER 4 MASONRY• ALL LOCAL AND REGIONAL CODES. ( � , CONCRETE BLOC ,AVK � A&OI -SHEET NUMBER I 11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL i ( 'e .- - ' r _I REMAINS THE SAME"`." 1 FIELD COORDINATE AND OBTAIN APPROVALS FROM THE ( 4 ARCHITECT/ENGINEER BEFORE ANY CUTTING,NOTCHING,OR DOOR IDENTIFICATION ` -1 RIDGIDINSULATION a ''.- i DRILLING OF ANY CAST-IN-PLACE CONCRETE,STRUCTURAL i � .t. ��Lqg j FRAMING,OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY ? *I ' AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. f BATT INSULATION ,'TASSO a <- 308, DOOR NUMBER - t. , ,, >e U) f ,{ Aga -e 7 ` '<. �N .; v J 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING c ! �. " ;F ) GRADES AND SCALE OUT THE BUILDING FOOTPRINT FOR OWNER ? . 1 1 > Q AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK.` GYPSUM PLASTER - 1 w W ROOM/SPACE/AREA IDENTIFICATION Z 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER r iri '. i f"' Z CONDITIONS,ROOF&DECK SURFACES MUST BE MAINTAINED I ROOM NAME ROOM NAME L'r�,' tr: a PLYWOOD -f:.,,,-;,--` i U-1 Z ( ' REASONABLE FREE OF ICE&SNOW TO ENSURE MINIMAL 77 EL,S7,3,..0� ,. W O t 6 1 314 I —ROOM NUMBERIli - - _ ." � �` �'�' + PROBLEMS WITH THESE SURFACES. I . J 876 SF --- ROOM AREA r�r j � '>, a_ Q 14. SUBSTITUTIONS OF"EQUAL"PRODUCTS WILL BE ACCEPTABLE i ! I rte,; �, FINISH WOOD _ WITH ARCHITECT'S WRITTEN APPROVAL. fes- - PARTITION TYPE IDENTIFICATION w W - 15. ITIS THE INTENT AND MEANING OF THESE DOCUMENTS THAT a THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE 4.4>A PARTITION TYPE,RE: 0 ALL LABOR,MATERIALS TRANSPORTATION,SUPPLIES,EQUIPMENT,! i PARTITION TYPE SCHEDULE ETC.TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED { _ EXISTING WALL TYPES r STANDARDS OF THE INDUSTRY. EXISTING FLOOR/CLG ASSEMBLIES ACOUSTICAL PARTITION TYPE IDENTIFICATION T B 1 A _ 16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE { ! T. Trw I.,S o n a� a t'i AND/OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS. PARTITION TYPE;RE :'"O" llr L.x z'ca:""EYP , + __� No. Description Date NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. PARTITION TYPE SCHEDULE 1 ' c --- mi..v';wn r.rrwcxL. ( STRUCTURAL GRID 1 C_ __ I ( ea�`�`5uai Ew>F.w�a I2 R 1 j - 17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE m n — r s ss"rarFXGVRS9 TOrY �° - LOCATIONS OF ALL EXISTING UTILITIES. ALL UTILITIES SHALL BE p COLUMN LETTER -� 1 sr ELMO OMt.PN 2,,, 4 / �° LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO; E THE SITE. C i I 26 2 :. ``yr0,1REi-NIAAMN1 ..CPsmrrw ( �� _ ( - -. E -`1 — �_ f tt cccaaacasse � _— , - r P'"..-__mw.cueyua ns scm„ww. v. �.. 11 womb 18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF -COLUMN REFERENCEtat - GUIDE EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL j \L' - VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF COLUMN LETTER 1 µ mw ; t P P. s a fqx ShUtA£fl 1 R`C4'SJYEYE , r-2"4GNCA`ff[499RSkAP: f _.--.-�.._ DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-I I' OK'F` / � t. V I 101 j AREASOF ELEVATION DATUM IDENTIFICATION i 1 W s aha _G _T, DISTURBED LANDSCAPE EXCAVATION. ALL LEVEL NAME �_ -- __ DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-� -d 1_�� f(j` DISTURBED LANDSCAPE. E � H'ODTH I DESCRIPTION y SUFFIX I%MOTH i;DESCRIPTION _ 1 SUFFIX 10,5TH i DESCRIPTION 1 SEEM 4 I I TYPE 01 S 4 TYPE Al I S TYPE Al - u— III 19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS i E �`--ELEVATION ; ! I .esenswrc \`amij TP i TYPE 02 - TYPE; AZ TYPE as i s ' i ENGINEER. -- _. rsOx zT r"s k t pE.,.C-0.4.1DY2k+R. /'� TYPE 03 ( tTYPE AS TYPE A3 Pro}eIXnumbet Project Number �. aesw�+ra+csas ars�,rr�.xe�ns. 1YPE� �_1 I j TYPE As .TYPE A¢ __-` Date 4/10/18 20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE 4 Draw by Author DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS. 1 I THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR COVER SHEET LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT. 1 - A000 l z- _�_ _�;, �__ KEY: WALL TYPES KEY: WALL TYPES ; r - --'--_----:1 NEW CONSTRUCTION ' w I BOYS'ROOMEXISTING L i —. - , ,,,--'-''-'-'1 48 it C 1 DEMO IF-11 1 a c---!--'-- I 1 _ GIRLS`ROOM •-- r 43 ( l buYb t.LObt11 1 i" I I DEMO .„,,,I Li = — i 1 49 'r OE CO4n.. r� C �" x � ---MOVE DOORS; €, "REF.PROPOSED PLAN-- 3 i €1 EL ' TOR (� p -t----- �"� I ; ! € ovaR �.Li i 1 I " L. EL "•TOR 7:b,ivA,,,,,,,..41,,,,, f-�wEm c ,. < 1 1 11,A E �v k BOI �� jL.,,1 -'`a?' ' ,‹1 11 ,,. .V.,,11°°Il '.- ,, , ,, , „-„. 11Liil 1 " � i C II II Ii-I3 �' _: f4a _' i �� � �� �. ,--- Imo c � �� \ Iii -REMAINS THE SAME if4 i --- i.. i -- t •. `t .,. -}- i �1 ,t. i -` r-' i t-- .�.�.•'1 E _—__ FLOOR PLAN-DEMO PIAN FLOORPLAN-PROPOSED J V4„=1,_0, '—i 114"=1'-0" 11.1 0 i (� W s 1.1 ii 1 H 1' (J) Z W p sl 1 W -' ', CL F- Q i 'T.---- __------11: ; I ; 41,4" J w I 1 2'-6" 2'.4" I f u- p r-----7,,S i! � til Si 3 � � -RETE�� �� No. Description } Date I ii iS FE-USi :,,._.it \ ,tt 1 t E ' < t..„--6-,-.....,1 7.,sr; , .,,„.------i., i 2'-6114" 2`-6": f h I M i I I \ { P\number Pro ect Number< 1 ' A Project 0" 10 7/16":,,,,,.. ,; 1 1 Date 411Qhor Draw„PY Author F ( _ - ' €i FLOORPLANS 2'-1114" I 2'-1113/16" I k 0-3" ,��°C / 1 1 0'-3 1/2° )0'-3 1,2. / a 2'-1374" 2'-6" r ENLARGED PLAN-NEW CONSTRUCTION 2 ° A O V 3 10" zi C