Loading...
HomeMy WebLinkAboutB18-0168_Approved Plans_1526406284.pdf10APR2018 05/15/18 10APR2018 05/15/18 10APR2018 05/15/18 10APR2018 05/15/18 10APR2018 05/15/18 Copyright © 2018 by Zehren & Associates Inc.SCALE: 1" = 10'-0" 5' 10' 0 20' L1.1 1 SITE PLAN 1" = 10'-0" EROSION CONTROL & SITE PROTECTION NOTES & SPECIFICATIONS: 1. SILT FENCE OR HAY BALES ARE TO BE PLACED AT THE LIMIT OF CONSTRUCTION AS NEEDED TO PREVENT EROSION AND SEDIMENTATION. A CONSTRUCTION FENCE WILL BE PLACED AT THE LIMIT OF DISTURBANCE WHERE THE SILT FENCE OR HAY BALES ARE NOT USED. 2. ALL TREES WITHIN THE LIMITS OF DISTURBANCE THAT ARE TO BE PRESERVED SHALL BE PROTECTED: AT EVERGREEN TREES WITH SNOW FENCING AT DRIP-LINE; AT DECIDUOUS TREES USE SNOW FENCING AT DRIP-LINE. IF YOU CANNOT PROVIDE SNOW FENCE @ DRIP-LINE DUE TO CONSTRUCTION PROXIMITY, WRAP TRUNK WITH PLASTIC CORRUGATED CULVERT SECTIONS TO A HEIGHT OF 6' OR TO FIRST MAJOR BRANCH. IF IT IS NECESSARY TO DRIVE WITHIN THE DRIP-LINE OF THE TREE, CONTRACTOR SHALL INSTALL 4" OF BARK MULCH OR WOOD CHIPS IN A RING EXTENDING FROM THE TRUNK TO THE TREE'S DRIP LINE. 3. SPECIAL CARE NEEDS TO BE TAKEN FOR TREES WITHIN CONSTRUCTION ACCESS ROUTE AND WORK AREAS. PLASTIC CORRUGATED CULVERT SECTIONS WITH INTERIOR INSULATION OF 1.5" MIN. TO SURROUND TREE TRUNK TO A HEIGHT OF 6' OR TO FIRST MAJOR BRANCH. 4. ERECT AND MAINTAIN TEMPORARY FENCING AROUND TREE PROTECTION ZONES BEFORE STARTING SITE CLEARING. REMOVE FENCE WHEN CONSTRUCTION IS COMPLETE. DO NOT STORE CONSTRUCTION MATERIALS, DEBRIS, OR EXCAVATED MATERIAL WITHIN FENCED AREA. DO NOT PERMIT VEHICLES, EQUIPMENT OR FOOT TRAFFIC WITHIN FENCED AREA. MAINTAIN FENCED AREA FREE OF WEEDS AND TRASH. 5. DO NOT EXCAVATE WITHIN TREE PROTECTION ZONES, UNLESS OTHERWISE INDICATED. WHERE EXCAVATION FOR NEW CONSTRUCTION IS REQUIRED WITHIN TREE PROTECTION ZONES, HAND CLEAR AND EXCAVATE TO MINIMIZE DAMAGE TO ROOT SYSTEMS. USE NARROW-TINE SPADING FORKS COMB SOIL TO EXPOSE ROOTS AND CLEANLY CUT ROOTS AS CLOSE TO EXCAVATION AS POSSIBLE. 5.1. COVER EXPOSED ROOTS WITH BURLAP AND WATER REGULARLY. 5.2. TEMPORARILY SUPPORT AND PROTECT ROOTS FROM DAMAGE UNTIL THEY ARE PERMANENTLY REDIRECTED AND COVERED WITH SOIL. 5.3. COAT CUT FACES OF ROOTS MORE THAT 1.5'' IN DIAMETER WITH AN EMULSIFIED ASPHALT OR OTHER APPROVED COATING FORMULATED FOR USE ON DAMAGED PLANT TISSUES. 5.4. BACKFILL WITH SOIL AS SOON AS POSSIBLE 6. ALL DISTURBED AREAS NOT DESIGNATED AS SHRUB BEDS, PERENNIAL BEDS, OR LAWN SHALL BE REVEGETATED WITH THE SPECIFIED SEED MIXTURE. 7. PROVIDE SILT FENCE OR SNOW FENCING AROUND ALL REVEGETATED AREAS FOR A MINIMUM OF ONE YEAR PERIOD OF ESTABLISHMENT (TWO YEARS IDEAL), PARTICULARLY FOR SEEDED SHRUBS. SITE CALCULATIONS TOTAL SITE AREA (COMBINED PARCEL A & B) x 18,442 SF TOTAL LANDSCAPE AREA (COMBINED PARCEL A & B) x 11,100 SF = 60% OF TOTAL SITE AREA x NET LOSS OF 40 SF AT LANDING TO THE NORTH OF MAIN ENTRY HARDSCAPE AREA x NET GAIN OF 151 SF OF SNOWMELTED FLAGSTONE PATIO (36 SF OF WHICH WERE PREVIOUSLY EXISTING DECK) SITE COVERAGE x NO MODIFICATIONS PROPOSED GRFA x NO MODIFICATIONS PROPOSED NOTES: 1. NO MODIFICATIONS TO THE BUILDING FOOTPRINT, FLOOR PLANS, OR GRFA ARE PROPOSED IN THIS APPLICATION. 2. SITE COVERAGE CALCULATIONS FOR BLDG HT, UNITS, PARKING AREA, DRIVEWAY AREA, AND SNOW STORAGE REMAIN UNCHANGED.Z:\2016\162473\IV. Current Documents\04. Plot Sheets\L1.1 Site Plan.dwg, 4/10/2018 2:52:15 PM, DWG To PDF.pc310APR2018 provide manufactures deck intall instructions for rough mechanical inspection of fire pit Provide timer shut off for fire pit max 30min 05/15/18 10APR2018 05/15/18 10APR2018 05/15/18 10APR2018 05/15/18 10APR2018 05/15/18 10APR2018 STRUCTURAL ENGINEER TO PROVIDE WALL DETAIL FOR TIE-IN TO VERIFIED EXISTING CONSTRUCTION. CONTRACTOR TO COORDINATE SITE DRAINAGE WITH FINAL WALL DETAILS. 05/15/18 10APR2018 05/15/18 Ensure there are existing or provide smoke and carbon monoxide detectors throughout the existing house per code prior to Final Building Inspection 05/15/18 05/15/18 05/15/18 From: Bill Muff bill@d-dkitchens.com Subject: vail kitchen drawings Date: May 4, 2018 at 12:09 PM To: logworks@msn.com 05/15/18