A18-0034_approved documents_1528751998.pdf
Project: The Lion Building Unit E-305 fire alarm modification. Address: 701 West Lions Head Cir., Vail , CO 81657 Fire alarm contractor: Dimant Technologies LLC SCOPE OF WORK LETTER Relocate NE bedroom speaker-strobe combo to the ceiling due to the wall removal, and replace it with a ceiling mount device. Attachments: 1. Edwards Signaling EGCF-S2VM – speaker-strobe combo data sheet 2. Edwards Signaling EGCF-S2VM – speaker-strobe combo wiring diagram Daniel Dimitrov NICET Fire Alarms Level III Cert. #119879 Digitally signed by Daniel Dimitrov DN: cn=Daniel Dimitrov, o=Dimant Technologies LLC, ou, email=dimitrov.dimant@gmail.co m, c=US Date: 2018.06.07 08:51:43 -06'00' Vail Fire & Emergency Services 06/11/18 Installation Sheet 15DEC05 P/N: 3100614 REV: 5.0 Genesis Ceiling Speaker-Strobe 1 / 4 Genesis Ceiling Speaker-Strobe Product description The Genesis Ceiling Speaker-Strobe is a fire alarm notification appliance designed for indoor ceilings and walls. See Table 1 for a list of model numbers. The speaker-strobe includes field configurable switches for selecting both the desired candela output and wattage tap. These settings are locked in place and remain visible after final installation. This strobe features an enhanced synchronization circuit to comply with the latest requirements of UL 1971 Signaling Devices for the Hearing Impaired. Synchronized operation requires a separately installed synchronization control module. See Table 2 for a list of compatible synchronization modules. Install this device in accordance with applicable requirements in the latest editions of the NFPA codes and standards and Canadian Electrical Code, Part 1, Section 32, CAN/ULC-S524- 2001, Standard for the Installation of Fire Alarm Systems, and in accordance with the local authorities having jurisdiction. Table 1: Models Description Number Speaker-strobe, 25 Vrms, 15 to 95 multi- cd, white ADTGC-S2VM MGC-S2VM EGC-S2VM XLSGC-S2VM GC-S2VM ZGC-S2VM GC-S2VM-LG Speaker-strobe, 25 Vrms, 15 to 95 multi- cd, white, with FIRE marking ADTGCF-S2VM MGCF-S2VM EGCF-S2VM XLSGCF-S2VM GCF-S2VM ZGCF-S2VM GCF-S2VM-LG Speaker-strobe, 70 Vrms, 15 to 95 multi- cd, white ADTGC-S7VM MGC-S7VM EGC-S7VM XLSGC-S7VM GC-S7VM ZGC-S7VM GC-S7VM-LG Speaker-strobe, 70 Vrms, 15 to 95 multi- cd, white, with FIRE marking ADTGCF-S7VM MGCF-S7VM EGCF-S7VM XLSGCF-S7VM GCF-S7VM ZGCF-S7VM GCF-S7VM-LG Speaker-strobe, 70 Vrms, 15 to 95 multi- cd, red, with FIRE marking EGCFR-S7VM GCFR-S7VM MGCFR-S7VM Table 2: Compatible synchronization modules Description Model number Auto-Sync Output Module SIGA-CC1S SIGA-MCC1S SIGA-CC1S-LG SIGA-MCC1S-LG Genesis Signal Master - Remote Mount ADTG1M-RM MG1M-RM EG1M-RM XLSG1M-RM G1M-RM ZG1M-RM G1M-RM-LG Specifications Operating voltage Speaker: 25 Vrms (model S2) or 70 Vrms (model S7) Strobe: Regulated 16 to 33 Vdc, 16 to 33 Vfwr This device was tested to the regulated 24 Vdc/fwr operating voltage limits of 16 V and 33 V. Do not apply 80% and 110% of these values for system operation. Supervisory voltage: 30 V maximum Sound level output: See Table 3 Speaker response: 400 to 4,000 Hz Strobe operating current: See Table 4 Light output: Selectable at 15, 30, 75, and 95 cd Synchronization: Meets UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ω. Refer to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. Wire size: 12 to 18 AWG (2.50 to 0.75 sq mm) Compatible electrical boxes North American 4 in square electrical box, 2-1/8 in deep (UL/ULC listed flush mounted with no extension ring) Operating environment Temperature: 32 to 120 °F (0 to 49 °C) Humidity: 0 to 93% RH, noncondensing at 90 °F (32 °C) Agency listings: Meets ULC-S541, year 2004 UL requirements for standards UL 1638 and UL 1971 (see Figure 1), and complies with UL 1480 fifth edition. Meets BS EN 60065:2002. Nameplate marking is located on the inside surface of the device. Table 3: Sound level output (dBA) Wattage 25V (UL) 25V (ULC) 70V (UL) 70V (ULC) 1/4 W 80 78 80 81 1/2 W 84 81 84 81 1 W 87 87 87 87 2 W (UL) 90 91 2.2 W (ULC) 90 90 Vail Fire & Emergency Services 06/11/18 P/N: 3100614 REV: 5.0 15DEC05 Installation Sheet 2 / 4 Genesis Ceiling Speaker-Strobe Table 3: Sound level output (dBA) Wattage 25V (UL) 25V (ULC) 70V (UL) 70V (ULC) dBA = Decibels, A-weighted UL 1480: Sound level output at 10 ft (3.05 m) measured in a reverberant room using 400 to 4,000 Hz band limited pink noise. ULC-S541: Meets or exceeds 85 dBA in an anechoic chamber at 10 ft (3.05 m). Directional characteristics: Within 6 dB of on-axis sound level when measured 90° off-axis (horizontal). Table 4: Strobe operating current in RMS (A) 15 cd 30 cd 75 cd 95 cd Vdc 0.109 0.151 0.281 0.318 Vfwr 0.131 0.194 0.379 0.437 Vdc = Volts direct current, regulated and filtered Vfwr = Volts full wave rectified Operating currents shown above were measured by UL at 16 Vdc and 16 Vfwr. 1009590858075706560555045403530252015105051015202530354045505560657075808590951000 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 -5 -10 -15 -20-25-30-35-40 -45 -50 -55 -60 -65 -70 -75 -80 -85 -90 Angle Percentage of rated output Horizontal and vertical outputs have the same pattern. Figure 1: UL 1971 minimum light output (% of rating vs. angle) Installation instructions Warning: To reduce the risk of shock, disconnect all power and allow 10 minutes for stored energy to dissipate before handling. Caution: Electrical supervision requires the wire run to be broken at each terminal. Do not loop the signaling circuit field wires around the terminals. Note: When installed, these devices are not centered on the electrical box. Make sure boxes are mounted to compensate for this difference. See Mounting template. To install the speaker-strobe: 1. Open the cover by depressing the tabs on either side of the unit with a small screwdriver. Hinge the cover down, to access the mounting screws and selectable candela and wattage switches. The cover is also detachable for installation convenience. 2. If temporal strobe (private mode) operation is desired, cut jumper JP1. See Figure 2. 3. Connect the speaker and strobe terminals to the signal circuit field wiring. You must observe polarity for the unit to function properly. See Figure 3. 4. Slide the wattage switch to the desired wattage tap (2 W, 1 W, 1/2 W, or 1/4 W) by aligning it with the indicator below the switch. See Figure 4. 5. Slide the candela switch to the desired candela output (15, 30, 75, or 95 cd) by aligning it with the indicator below the switch. See Figure 4. 6. Mount the unit onto a compatible electrical box. See Figure 5. 7. Reattach and/or hinge the cover up to latch into place. 8. Test the unit for proper operation. To change the from 1 fps (public mode) to temporal (private mode) cut jumper JP1 strobe signal output JP1 1/2 1 / 4 1 2 Figure 2: Strobe setting Note: If the strobe is set to temporal (private mode), this device is no longer UL 1971 listed and FM Approved but is UL 1638 listed. To next device or end of line device SPKRS-CS+S SPKRS-CS+S + +++ To listed fire alarm control panel Input voltage matching the voltage rating of the speaker (25 or 70 Vrms) Input voltage matching the voltage rating of the strobe Figure 3: Wiring diagram Vail Fire & Emergency Services 06/11/18 Installation Sheet 15DEC05 P/N: 3100614 REV: 5.0 Genesis Ceiling Speaker-Strobe 3 / 41/41 / 2 1 2 Wattage switch Indicator95751530Candela switch Indicator Figure 4: Field configurable switches Figure 5: Mounting diagram Maintenance This unit is not serviceable or repairable. Should the unit fail to operate, contact the supplier for replacement. Perform a visual inspection and an operational test twice a year or as directed by the local authority having jurisdiction. Vail Fire & Emergency Services 06/11/18 P/N: 3100614 REV: 5.0 15DEC05 Installation Sheet 4 / 4 Genesis Ceiling Speaker-Strobe Mounting template To center the speaker-strobe: 1. Position the template to the center of the ceiling tile. 2. Orient the strobe to the desired visual position. 3. Mark the location for the electrical box. SPEAKER STROBE BOX 4 1/16" (10.316 cm) Cut location for electrical box Center of ceiling tile or speaker-strobe Vail Fire & Emergency Services 06/11/18 Page 1 of 4 D ATA S H E E T S85001-0556 Not to be used for installation purposes. Issue 8 Edwards Signaling Catalog u Speakers, Telephones 06-27-13Overview Genesis life safety ceiling speaker-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis speaker- strobes blend with any decor. Life safety appliances feature textured housings in architecturally neutral white or eye-catching life safety red. Thanks to patented breakthrough technology, Edwards Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consistent illumination from the strobe flash. Depending on the model, Genesis clear-lens speaker-strobes feature 15 to 95, or 95 to 177 candela output (see ordering infor- mation), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Standard Features • Field configurable – no need to remove the device! – Select ¼, ½, 1, or 2 watt operation – 15/30/75/95 cd and 95/115/150/177 cd clear strobe lens models available – Switch settings remain visible even after the unit is installed • Unique low-profile design – 30 per cent slimmer profile than comparable signals – Available with white or red housings • Unparalleled performance – loud 90 dBA output ensures clear, crisp audio – Precision timing electronics meet tough synchronizing standards for strobes when used with compatible modules – 25 VRMS and 70 VRMS models available, all supplied with a DC blocking capacitor for audio circuit supervision • Easy to install – Fits all standard 4" square electrical boxes with plenty of room for extra wire – no extension ring or trim plate needed – #18 - #12 AWG terminals – ideal for long runs, existing wiring • Approved for public and private mode applications – UL 1971-listed as signaling devices for the hearing impaired – UL 1638-listed as protective visual signaling appliances – UL 1480-listed as life safety speaker – UL/ULC listed for ceiling or wall use Field Configurable Ceiling Speaker -strobes Genesis Series MEA Vail Fire & Emergency Services 06/11/18 Page 2 of 4 D ATA S H E E T S85001-0556 Not to be used for installation purposes. Issue 8 Strobe Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing codes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. Speaker Application The suggested sound pressure level for each signaling zone used with alert or alarm signals is a minimum of 15 dB above the aver- age ambient sound level or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater. This is measured 5 feet (1.5 m) above the floor. Doubling the distance from the signal to the ear will theoretically cause a 6 dB reduction in the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. Doubling the power output of a device (e.g.: a speaker from 1 W to 2 W) will increase the sound pressure level by 3 dBA. A 3 dBA difference represents a barely noticeable change in volume. Combination audible/visual signals must be installed in accor- dance with guidelines established for strobes. Installation and Mounting All models are intended for indoor ceiling or wall applica- tions only. Speaker-strobes are mounted to a flush North-American 4" square electrical box, 21/8" (54 mm) deep. Genesis ceiling speaker- strobes simply unlatch and hinge down to open. This gains access to mounting screws and the selectable candela wattage tap switches. The shallow depth of Genesis devices leaves ample room behind the signal for extra wir- ing. Once installed with the cover in place, no mounting screws are visible. Installation Note: When installed, these devices are not centered on the electrical box. Make sure boxes are mounted to compensate for this difference. Use the mount- ing template provided with installation sheet 3100614. Field Configuration Genesis ceiling speaker- strobes may be set for ¼, ½, 1, or 2 watt operation. De- pending on the model, Gen- esis ceiling speaker-strobes have multi-candela output (see ordering information). Output settings are changed by simply opening the device and sliding the switches to the desired settings. The speaker-strobe does not have to be removed to change the output settings. The settings remain visible through small windows on the front of the device after the cover is closed. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm² to 2.5 mm²) wiring.1/41/21 2 Wattage switch Indicator95751530Candela switch Indicator *Sound level output notes: dBA = Decibels, A-weighted. UL1480: Sound level output at 10 ft (3.05 m) measured in a reverberant room using 400 to 4,000 Hz band limited pink noise. ULC-S541: Meets or exceeds 85 dBA in an anechoic chamber at 10 ft (3.05 m). Directional characteristics: Within 6 dB of on-axis sound level when measured 90° off-axis (horizontal). Sound Level Output BOX Center of ceiling tile or speaker/strobe Center of Box 11/16" 1.0" (25 mm) 8.3" dia. (211 mm) 0.60"(15 mm) Dimensions Wattage 25V 25V 70V 70V UL Rated* Typical UL Rated* Typical ¼ W 80 dBA 80.7 dBA 80 dBA 81.1 dBA ½ W 84 dBA 83.7 dBA 84 dBA 83.5 dBA 1 W 87 dBA 87 .1 dBA 87 dBA 87.2 dBA 2 W 90 dBA 90.1 dBA 91 dBA 90.2 dBA Vail Fire & Emergency Services 06/11/18 Page 3 of 4 D ATA S H E E T S85001-0556 Not to be used for installation purposes. Issue 8 Current Draw Notes 1. Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. 2. Current values are shown in mA. UL Nameplate Rating UL Nameplate Rating (high cd output mod- els) See note 1 "15" or "D" "30" or "C" "75" or "B" "95" or "A" "95" or "D" "115" or "C" "150" or "B" "177" or "A" RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 109 151 281 318 330 392 502 565 16 Vfwr 131 194 379 437 432 518 643 693 Typical Current Typical Current (high cd output models) See note 1 "15" or "D" "30" or "C" "75" or "B" "95" or "A" 95 cd 115 cd 150 cd 177 cd RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 94 140 273 325 333 392 499 551 20 Vdc 74 108 205 244 259 303 378 429 24 Vdc 63 90 168 194 212 245 306 342 33 Vdc 48 70 124 139 155 180 211 236 16 Vfwr 126 187 368 403 484 570 673 724 20 Vfwr 108 156 281 333 380 438 537 604 24 Vfwr 97 139 240 270 318 361 434 484 33 Vfwr 89 119 197 214 245 269 308 338 0 1 2 3 4 5 6 7 8 9 10 11 121 2 3 4 5 6 7 8 9 10 11 12 0°15° 30° 45° 60° 75° 90° -15° -30° -45° -60° -75° 82 83 84 87 90 96 93 89 88 10ft (3.05m) Radius 5ft (1.5m)Radius 87 84 83 82 88 89 93 Feet From Speaker Typical Sound Output (dBA) Measured at 2 watts setting in anechoic chamber Light output - (effective cd) 0 10 20 30 40 50 60 70 80 90 100 110 12010 20 30 40 50 60 70 80 90 100 110 120 0°15° 30° 45° 60° 75° 90° -15° -30° -45° -60° -75° Angle Percentage of rated output Horizontal and vertical outputs reflect the same pattern. Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models available. Mounting Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep, or 960A-4RF round flush box. No extension ring required. Suitable for indoor wall or ceiling applications. Wire con- nections Screw terminals: polarized inputs for speaker, #18 to #12 AWG (0.75 mm² to 2.5 mm²) wire size Operating environment Indoor: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity. Agency listings/ approvals Meets ULC-S541, year 2004 UL requirements for standards UL1638 and UL1971, FM, MEA, CSFM, and complies with UL1480 Fifth Edition. All speaker-strobes comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. Speaker Input/Oper- ating Volts 25 Vrms (Model EGC-S2VM) or 70 Vrms (Model EGC- S7VM). Strobe Strobe out- put rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (VM models) and 95/115/150/177 cd (VMH models) Strobe operating voltage EGC-S2VM/-S7VM series speaker-strobes: non-coded, filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR Strobe flash rate EGC-S2VM/-S7VM series speaker-strobes: one flash per second synchronized with optional EG1M Genesis Sig- nal Master indefinitely within 10 milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit Synchroni- zation Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer to specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. Synchro- nization Sources EG1M-RM, EBPS6A, EBPS10A, E-NAC, E-FSC, E-FSA Lens Optical grade polycarbonate Specifications Percent of UL rating versus angle Vail Fire & Emergency Services 06/11/18 Page 4 of 4 D ATA S H E E T S85001-0556 Not to be used for installation purposes. Issue 8 06-27-13Contact us... Phone: 1-800-336-4206 Web: www.edwardssignaling.com Edwards Signaling is an EDWARDS brand. 3 Farm Glen Boulevard Farmington, CT 06032 In Canada, contact Chubb Edwards... Email: inquiries@chubbedwards.com Web: www.chubbedwards.com © 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. Specifications subject to change without notice. Edwards is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. Ordering Information Model Hous- ing Mark- ing Lens Strobe Speaker Ship Wt. Life safety Appliances (c/w running man icon screen printed on housing) EGC-S2VM White None Clear Selectable 15, 30, 75, or 95 cd 25 Volt 2.25 lb. (1.0 kg.) EGCF-S2VM White FIRE EGC-S2VMH White None Selectable High Output 95, 115, 150, or 177 cdEGCF-S2VMH White FIRE EGC-S7VM White None Selectable 15, 30, 75, or 95 cd 70 Volt EGCF-S7VM White FIRE EGCFR-S7VM Red FIRE EGC-S7VMH White None Selectable High Output 95, 115, 150, or 177 cdEGCF-S7VMH White FIRE Accessories EG1M-RM Synchronization Output Module (1-gang) 0.2 (0.1) All speaker-strobes include field- selectable ¼, ½, 1, or 2 watt taps WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safe- guards such as backup power supplies may be required. Edwards recommends that these speaker- strobes always be installed in accordance with the latest recognized edition of national and local codes. Vail Fire & Emergency Services 06/11/18