HomeMy WebLinkAboutB18-0080_Approved Plans_1529941534.pdf1
A5.01
1
A5.11
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
BUILDING SECTION IDENTIFICATION
WALL SECTION IDENTIFICATION
1
A9.01 SHEET NUMBER
DRAWING NUMBER
DETAIL IDENTIFICATION
INTERIOR ELEVATION IDENTIFICATION
1
A6.01 SHEET NUMBER
DRAWING NUMBER
ENLARGED DETAIL IDENTIFICATION
AREA OF DRAWING TO
BE ENLARGED
SECTION MATERIAL
GRAPHICS
23A
76H
PARTITION TYPE; RE:
PARTITION TYPE SCHEDULE
PARTITION TYPE; RE:
PARTITION TYPE SCHEDULE
PARTITION TYPE IDENTIFICATION
ACOUSTICAL PARTITION TYPE IDENTIFICATION
308 DOOR NUMBER
DOOR IDENTIFICATION
ROOM NAME
314
876.00 SF
ROOM NUMBER
ROOM/SPACE/AREA IDENTIFICATION
ROOM NAME
ROOM AREA
A
1
COLUMN LETTER
COLUMN LETTER
COLUMN REFERENCE
GUIDE
STRUCTURAL GRID
ELEVATION
LEVEL NAME
BATT INSULATION
CONCRETE
UNDISTURBED OR
COMPACTED EARTH
POROUS FILL
(GRAVEL)
STEEL
ALUMINUM
MASONRY - BRICK
MASONRY -
CONCRETE BLOCK
RIDGID INSULATION
GYPSUM PLASTER
PLYWOOD
FINISH WOOD
EXTERIOR ELEVATION IDENTIFICATION
1
A4.01
A7.01
99
99
99
99
C1 WINDOW TYPESHEET NUMBER
DRAWING NUMBER
?
WINDOW IDENTIFICATION
KEYNOTE IDENTIFICATION
NOTE NUMBER
001
ASI
REVISION IDENTIFICATION
REVISION NUMBER
REVISION DESCRIPTION
ELEVATION DATUM IDENTIFICATION
GRAPHIC STANDARDS
VICINITY MAPCHALETS THE LODGE
AT VAIL UNIT 11
BUILDING PERMIT SUBMITTAL
03.06.18
k.h.webb Vail, Colorado
Project number
Date
Drawn by k . h . w e b ba r c h i t e c t s . p c710 WEST LIONSHEAD CIRCLE . VAIL SPA CONDOMINIUMSUNIT A . VAIL . COLORADO 81657970.477.2990 970.477.2965(F)A000
COVER SHEET
000000CHALETS THE LODGE ATVAIL UNIT 11BVAIL 03.06.18
CGM
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS.
2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING
ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR
DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY.
3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN
APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE
PARTICULAR AREAS.
4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD
COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION
DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR
BEAMS UNLESS OTHERWISE NOTED.
5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS
INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET
ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS.
6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. INTERIOR REMODEL TO REUSE
EXISTING DOORS.
7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. THERE ARE NO WINDOW
MODIFICATIONS IN THIS PROPOSED INTERIOR REMODEL.
8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING
FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS.
9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE
CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL
IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT
SHALL NOT CONSTITUTE A DELAY IN THE PROJECT.
10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL
APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS
PROJECT IS GOVERNED BY THE INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL
RESIDENTIAL CODE. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS
SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING
THE IBC AND ALL LOCAL AND REGIONAL CODES.
11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND
OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING,
OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER
STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE
CONSTRUCTION.
12. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S
WRITTEN APPROVAL.
13. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL
CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS
TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE
RECOGNIZED STANDARDS OF THE INDUSTRY.
14. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING
UTILITIES INCLUDING BUT NOT LIMITED TO GAS, WATER, SEWER, ELECTRIC, FIRE ALARM,
FIRE SUPPRESSION, SPRINKLERS, CARBON MONOXIDE SENSORS, CABLE AND
COMMUNICATION LINES. FIELD COORDINATE EXTENDING, REPLACING AND VERIFYING
CORRECT OPERATION OF ALL UTILITIES FOR EXISTING AND REMODELED SPACES.
CODE:
2015 IBC AS ADOPTED BY THE TOWN OF
VAIL
ZONING:
SKI BASE / RECREATION 2
OCCUPANCY CLASSIFICATION:
RESIDENTIAL GROUP R-2
CONSTRUCTION TYPE(S):
SPRINKLERED: YES
PARCEL NUMBER:
2101-082-87-001
DRAWING INDEX
SITE:
CHALETS AT THE LODGE OF VAIL UNIT 11
ARCHITECTURAL:
A000 COVER SHEET
A100 LEVEL 1 FLOOR PLAN
A101 LEVEL 2 FLOOR PLAN
A102 LEVEL 3 FLOOR PLAN
A103 LEVEL 3.5 & LEVEL 4 FLOOR PLAN, NEW STAIR SECTION
A150 LEVEL 4 REFLECTED CEILING PLAN
STRUCTURAL
S1 FOUNDATION PLAN & BASE PLATE
S2 2ND LEVEL FRAMING PLAN & DETAILS
S3 3RD LEVEL FRAMING PLAN
S4 4TH LEVEL FRAMING, PETE'S PERCH FRAMING PLAN AND DETAILS
S5 ROOF FRAMING PLAN
S6 KITCHEN ROOF SECTIONS AND DETAILS
ELECTRICAL
1A 1.01 LEVEL 1 & LEVEL 2 FLOOR PLANS
1A 1.02 LEVEL 3 & LEVEL 4 FLOOR PLANS
1A 4.01 LEVEL 1 & LEVEL 2 REFLECTED CEILING PLANS
1A 4.02 LEVEL 3 & LEVEL 4 REFLECTED CEILING PLANS
PROJECT TEAM:
ARCHITECT:
K. H. WEBB ARCHITECTS
710 W. LIONSHEAD CIRCLE, UNIT A
VAIL, CO 81657
PH: 970.477.2990
CONTACTS:
KYLE WEBB
GENERAL CONTRACTOR:
SRE BUILDERS
P.O. BOX 6376
VAIL, CO 81658
PH: 970.845.6359
CONTACT: STEVE ELICKER
STRUCTURAL ENGINEER
THE MJ MUELLER CO. INC.
PO BOX 2747
VAIL, CO 81658
PH: 970.476.2627
CONTACT: MARK MUELLER
INTERIOR DESIGNER:
KEN FULK
310 7TH STREET
SAN FRANCISCO, CA 94103
PH: 415.285.1164 EXT. 127
CONTACT: KRISTIN SIMMONS
BUILDING & CODE INFORMATION
UNIT 11
BEFORE
AFTER
SEE ORIGINAL CONSTRUCTION DOCUMENTS:
VAIL'S FRONT DOOR BUILDING E.
DOCUMENTS AS PREPARED BY OWNER /
DEVELOPER, VAIL RESORTS DEVELOPMENT
COMPANY AVON, COLORADO.
ARCHITECT OF RECORD 4240 DENVER, CO.
PROJECT NO: 20693.03 , ISSUE ASIE-056
DATED 09.10.07 FOR BUILDING 5 UNIT 11(5C)
No. Description Date
06/25/18
UP
DN
UP
A
8
B
C
10' - 8" 4' - 2" D
E
F
3' - 9 1/2" 9' - 10 1/2" 4' - 0"6 5 4 1
10' - 0" 1' - 5 1/2" 12' - 6 1/2" 26' - 0"
190' - 0"
189' - 6"
5' - 6"
BATH A
LIGHTWELL
EGRESS
FOYER
ELEVATOR
MECHANICAL
CLOSET 1 DATA
ROOM
195' - 0"
189' - 6"
8'-5 5/8"
CEILING
8'-6 3/8"
CEILING
8'-7 7/8"
CEILING
NOTE-
FLOOR PLAN LAYOUT BASED UPON ORIGINAL DRAWINGS AS PREPARED BY VAIL RESORTS
DEVELOPMENT COMPANY AND FIELD MEASUREMENTS. WALL LAYOUT IS TO FRAMING OR
CONCRETE. FIELD VERIFY EXISTING FINISHES AND EXACT MEASUREMENTS UPON
DEMOLITION OF REMODELED AREAS.ELEC.PANEL3' - 6"6" STEPCHANGE DOOR
SWING AS SHOWN
WALLS TO BE
REMOVED
TYPICAL
WALLS TO BE
ADDED TYPICAL
192' - 4"
OFFICE A
LOUNGE
2015 IBC SECTION 1030
EMERGENCY ESCAPE AND RESCUE
1030.1 GENERAL.
IN ADDITION TO THE MEANS OF EGRESS REQUIRED BY THIS CHAPTER, PROVISIONS SHALL BE MADE FOR
EMERGENCY ESCAPE AND RESCUE OPENINGS IN GROUP R-2 OCCUPANCIES IN ACCORDANCE WITH TABLES
1006.3.2(1) AND 1006.3.2(2) AND GROUP R-3 OCCUPANCIES. BASEMENTS AND SLEEPING ROOMS BELOW THE
FOURTH STORY ABOVE GRADE PLANE SHALL HAVE AT LEAST ONE EXTERIOR EMERGENCY ESCAPE AND RESCUE
OPENING IN ACCORDANCE WITH THIS SECTION. WHERE BASEMENTS CONTAIN ONE OR MORE SLEEPING ROOMS,
EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE REQUIRED IN EACH SLEEPING ROOM, BUT SHALL NOT
BE REQUIRED IN ADJOINING AREAS OF THE BASEMENT. SUCH OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC
WAY, OR TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY.
SEE BUILDING CODE FOR ACTUAL TEXT AND ADDITIONAL INFORMATION INCLUDING BUT NOT LIMITED TO
EXCEPTIONS, TABLES AND FOOTNOTES.
RAISE FLOOR AND
DOORS IN DATA
ROOM AND BUNK
ROOM
SKI ROOM
INFILL AS SHOWN
THICKEN WALLS
PER INTERIOR
DESIGNEROFFICE B
BATH B
BUILT IN'S PER
INTERIOR DESIGNER
DRAWINGS 7' - 7 1/2"5 1/2"3' - 0" 3 1/2" 7' - 7 1/2" NEW BATHROOM IN BASEMENT AREA.
COORDINATE REQUIRED PLUMBING
PENETRATIONS AND DRAIN LINES AS
REQUIRED IN EXISTING SLAB.
COORDINATE VENTING TO EXISTING
SYSTEM ABOVE.
4' - 6 1/2"3 1/2"12' - 8"
3 1/2"
3' - 0"
3 1/2"3' - 1"
3 1/2"8' - 2"
4' - 5"9"7' - 9 1/2"
PROVIDE FRESH AIR AND
EXHAUST MECHANICAL
VENTILATION IN ALL
ROOMS OF LEVEL 1
EXISTING WALLS
TO REMAIN
TYPICAL
0' 1' 4' 8' 16' 2'
1/4" = 1'-0"1 LEVEL 1 FLOOR PLAN
Project number
Date
Drawn by k . h . w e b ba r c h i t e c t s . p c710 WEST LIONSHEAD CIRCLE . VAIL SPA CONDOMINIUMSUNIT A . VAIL . COLORADO 81657970.477.2990 970.477.2965(F)A100
LEVEL 1 FLOOR PLAN
000000CHALETS THE LODGE ATVAIL UNIT 11BVAIL 03.06.18
CGM
No. Description Date
06/25/18
UP
DN
A
8
B
C
D
E
F
6 5 4 1
205' - 0"205' - 0"
FOYER
CORRIDOR
BEDROOM A BATH A
LAUNDRY A
JR MSTR
CLOSET
JR MSTR BATH
JUNIOR
MASTER
CLOSET A
PATIO ON GRADE
8'-8 1/8"
CEILING
8'-6 7/8"
CEILING
8'-7 1/2"
CEILING
8'-2 3/8"
CEILING
7'-8 1/2"
CEILING
SOFFIT
7'-9 5/8" CEILING
8'-7 1/4"
CEILING
8'-7 1/4"
CEILING
SOFFIT
7'-8" CEILING
7'-8 3/8"
CEILING
8'-6 7/8"
CEILING
7'-10 3/8"
CEILING
ELEVATOR
REMOVE EXISTING
TUB AND SHOWER
AND REPLACE PER
INTERIOR
DECORATOR
DRAWINGS WINDOW TO
BE ADDED
EXISTING WALL
TO BE
REMOVED
EXISTING WALLS TO
REMAIN TYPICAL
Project number
Date
Drawn by k . h . w e b ba r c h i t e c t s . p c710 WEST LIONSHEAD CIRCLE . VAIL SPA CONDOMINIUMSUNIT A . VAIL . COLORADO 81657970.477.2990 970.477.2965(F)A101
LEVEL 2 FLOOR PLAN
000000CHALETS THE LODGE ATVAIL UNIT 11BVAIL 03.06.18
CGM
1/4" = 1'-0"1 LEVEL 2 FLOOR PLAN
No. Description Date
06/25/18
UP
DN
A
8
B
C
D
E
F
6 5 4 1
215' - 0"
FAN COIL
ROOM
CORRIDOR
BEDROOM B
LAUNDRY B
MSTR CLOSET
BATH B
MSTR BATH
MASTER
BEDROOM
CLOSET B
DECKAIR VENT8'-7 1/2"
CEILING
8'-7 1/2"
CEILING
8'-7 1/2"
CEILING
7'-5 7/8"
CEILING
3'-7 5/8"
CEILING
8'-7 1/4"
CEILING
8'-7 3/8"
CEILING
SOFFIT 7'-7 1/2"
CEILING
SOFFIT 7'-8"
CEILING
7'-6 5/8"
CEILING
215' - 0"
REMOVE
EXISTING TUB
AND SHOWER
AND REPLACE
WITH WET
ROOM PER
INTERIOR
DECORATOR
DRAWINGS
WINDOW TO
BE ADDED
REMOVE
ANGLED
WALL
WALLS TO
BE ADDED
EXISTING WALLS
TO REMAIN
TYPICAL
Project number
Date
Drawn by k . h . w e b ba r c h i t e c t s . p c710 WEST LIONSHEAD CIRCLE . VAIL SPA CONDOMINIUMSUNIT A . VAIL . COLORADO 81657970.477.2990 970.477.2965(F)A102
LEVEL 3 FLOOR PLAN
000000CHALETS THE LODGE ATVAIL UNIT 11BVAIL 03.06.18
CGM
1/4" = 1'-0" 1 LEVEL 3 FLOOR PLAN
No. Description Date
06/25/18
DN
UP
REF.A
8
B
C
D
E
F
6 5 4 1
220' - 0"
225' - 0"
DECK
DECK
ELEVATOR
FOYER
8'-11 1/8"
CEILING
15'-2 7/8"
CEILING
13'-3 1/8"
CEILING
INFILL
PORTION OF
STAIRS
ENLARGE
EXISTING
COLUMN
WALLS TO BE
REMOVED TYPICAL.
SEE STRUCTURAL
DRAWINGS
3
A103
229' - 4"
BBQ
NEW WOOD
FINISH ON
STAIRS
NEW
HANDRAIL
TYPICAL
NEW STONE
FLOOR FINISH
REPLACE STONE
FINISH AND METAL
ENCLOSURE PER
INTERIOR DESIGNER
GENERAL NOTES
-NEW WOOD FLOOR PER
INTERIOR DESIGNER.
-REFINISH WOOD CEILING.
KITCHEN CEILING TO MATCH
-RECONFIGURE LIGHTING AND
SPEAKERS.
REFINISH PER
INTERIOR
DESIGNER
PETE'S
PERCH
3' - 0"
SEE REFLECTED
CEILING PLAN
FOR HEIGHTS
KITCHEN
GREAT ROOM
NEW STAIR
NEW LOFT ABOVE
ENTRY
EXISTING WALLS
TO REMAIN
TYPICAL
8
C
D
E
F
6 5
3
A103
REVERSE SWING
OF FRONT DOOR
EXISTING CLOSET
WALLS TO BE REMOVED
TYPICAL
WALLS TO
BE ADDED
TYPICAL
MOVE POWDER ROOM
TO ENTRY LEVEL
FOYER
EDGE OF FLOOR
ABOVE
EXISTING WALLS
TO REMAIN
TYPICAL
POWDER
LEVEL 4
225' - 0"
BEARING
233' - 9 1/2"
8 6 5
LEVEL 3.5
220' - 0" 4' - 4"NEW STAIRS TO
PETE'S PERCH
PER PLAN
NEW DROPPED CEILING
AT KITCHEN SEE
STRUCTURAL
DRAWINGS
LEVEL 4.5
229' - 4"
HANDRAIL TO
MATCH EXISTING
PER CODE
NEW FRAMED FLOOR
PER STRUCTURAL
DRAWINGS
UNDERFRAME FLOOR
JOISTS TO CONCEAL
FLITCH PLATE BEAM
RELOCATE POWDER
ROOM TO ENTRY LEVEL
PROVIDE PLUMBING
ALTERATIONS AS
REQUIRED
EXISTING LEVEL 4
FLOOR FRAMING
TO REMAIN
EXISTING WALLS
TO REMAIN
EXISTING ENTRY
FLOOR FRAMING
TO REMAIN
EXISTING ROOF
FRAMING TO REMAIN
PROVIDE INFILL
FRAMING BENEATH
NEW STAIRS AND
BETWEEN EXISTING
FLOOR FRAMING AS
REQUIRED
Project number
Date
Drawn by k . h . w e b ba r c h i t e c t s . p c710 WEST LIONSHEAD CIRCLE . VAIL SPA CONDOMINIUMSUNIT A . VAIL . COLORADO 81657970.477.2990 970.477.2965(F)A103
LEVEL 4 FLOOR PLAN
000000CHALETS THE LODGE ATVAIL UNIT 11BVAIL 03.06.18
CGM
1/4" = 1'-0" 1 LEVEL 4 FLOOR PLAN
1/4" = 1'-0"2
LEVEL 3.5 FLOOR
PLAN
1/2" = 1'-0"3
POWDER ROOM
SECTION
No. Description Date
06/25/18
A
8
B
C
D
E
F
6 5 4 14" / 12" 4" / 12"4" / 12"4" / 12"3
A103
FLAT CEILING
9'-3 5/8"
CEILING
HEIGHT
(F.V.)
11'-8 7/8" CEILING
HEIGHT (FIELD
VERIFY)
FLAT CEILING4" / 12"REVISE CEILING
FRAMING PER
STRUCTURAL
DRAWINGS
EXISTING WALLS TO
REMAIN TYPICAL
RAISE BEAM PER
STRUCTURAL
DRAWINGS
FIELD COORDINATE
ARCHITECTURAL WALL INFILL
WITH ARCHITECT AND
INTERIOR DESIGNER AT TIME
OF CONSTRUCTION
Project number
Date
Drawn by k . h . w e b ba r c h i t e c t s . p c710 WEST LIONSHEAD CIRCLE . VAIL SPA CONDOMINIUMSUNIT A . VAIL . COLORADO 81657970.477.2990 970.477.2965(F)A150
LEVEL 4 RCP
000000CHALETS THE LODGE ATVAIL UNIT 11BVAIL 03.06.18
CGM
1/4" = 1'-0"1 LEVEL 4 RCP
No. Description Date
06/25/18
06/25/18
06/25/18
06/25/18
06/25/18
06/25/18
06/25/18