Loading...
HomeMy WebLinkAboutB18-0080_Approved Plans_1529941534.pdf1 A5.01 1 A5.11 SHEET NUMBER DRAWING NUMBER SHEET NUMBER DRAWING NUMBER SHEET NUMBER DRAWING NUMBER BUILDING SECTION IDENTIFICATION WALL SECTION IDENTIFICATION 1 A9.01 SHEET NUMBER DRAWING NUMBER DETAIL IDENTIFICATION INTERIOR ELEVATION IDENTIFICATION 1 A6.01 SHEET NUMBER DRAWING NUMBER ENLARGED DETAIL IDENTIFICATION AREA OF DRAWING TO BE ENLARGED SECTION MATERIAL GRAPHICS 23A 76H PARTITION TYPE; RE: PARTITION TYPE SCHEDULE PARTITION TYPE; RE: PARTITION TYPE SCHEDULE PARTITION TYPE IDENTIFICATION ACOUSTICAL PARTITION TYPE IDENTIFICATION 308 DOOR NUMBER DOOR IDENTIFICATION ROOM NAME 314 876.00 SF ROOM NUMBER ROOM/SPACE/AREA IDENTIFICATION ROOM NAME ROOM AREA A 1 COLUMN LETTER COLUMN LETTER COLUMN REFERENCE GUIDE STRUCTURAL GRID ELEVATION LEVEL NAME BATT INSULATION CONCRETE UNDISTURBED OR COMPACTED EARTH POROUS FILL (GRAVEL) STEEL ALUMINUM MASONRY - BRICK MASONRY - CONCRETE BLOCK RIDGID INSULATION GYPSUM PLASTER PLYWOOD FINISH WOOD EXTERIOR ELEVATION IDENTIFICATION 1 A4.01 A7.01 99 99 99 99 C1 WINDOW TYPESHEET NUMBER DRAWING NUMBER ? WINDOW IDENTIFICATION KEYNOTE IDENTIFICATION NOTE NUMBER 001 ASI REVISION IDENTIFICATION REVISION NUMBER REVISION DESCRIPTION ELEVATION DATUM IDENTIFICATION GRAPHIC STANDARDS VICINITY MAPCHALETS THE LODGE AT VAIL UNIT 11 BUILDING PERMIT SUBMITTAL 03.06.18 k.h.webb Vail, Colorado Project number Date Drawn by k . h . w e b ba r c h i t e c t s . p c710 WEST LIONSHEAD CIRCLE . VAIL SPA CONDOMINIUMSUNIT A . VAIL . COLORADO 81657970.477.2990 970.477.2965(F)A000 COVER SHEET 000000CHALETS THE LODGE ATVAIL UNIT 11BVAIL 03.06.18 CGM GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. 2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR AREAS. 4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED. 5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS. 6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. INTERIOR REMODEL TO REUSE EXISTING DOORS. 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. THERE ARE NO WINDOW MODIFICATIONS IN THIS PROPOSED INTERIOR REMODEL. 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS. 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL RESIDENTIAL CODE. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING THE IBC AND ALL LOCAL AND REGIONAL CODES. 11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. 12. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN APPROVAL. 13. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. 14. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO GAS, WATER, SEWER, ELECTRIC, FIRE ALARM, FIRE SUPPRESSION, SPRINKLERS, CARBON MONOXIDE SENSORS, CABLE AND COMMUNICATION LINES. FIELD COORDINATE EXTENDING, REPLACING AND VERIFYING CORRECT OPERATION OF ALL UTILITIES FOR EXISTING AND REMODELED SPACES. CODE: 2015 IBC AS ADOPTED BY THE TOWN OF VAIL ZONING: SKI BASE / RECREATION 2 OCCUPANCY CLASSIFICATION: RESIDENTIAL GROUP R-2 CONSTRUCTION TYPE(S): SPRINKLERED: YES PARCEL NUMBER: 2101-082-87-001 DRAWING INDEX SITE: CHALETS AT THE LODGE OF VAIL UNIT 11 ARCHITECTURAL: A000 COVER SHEET A100 LEVEL 1 FLOOR PLAN A101 LEVEL 2 FLOOR PLAN A102 LEVEL 3 FLOOR PLAN A103 LEVEL 3.5 & LEVEL 4 FLOOR PLAN, NEW STAIR SECTION A150 LEVEL 4 REFLECTED CEILING PLAN STRUCTURAL S1 FOUNDATION PLAN & BASE PLATE S2 2ND LEVEL FRAMING PLAN & DETAILS S3 3RD LEVEL FRAMING PLAN S4 4TH LEVEL FRAMING, PETE'S PERCH FRAMING PLAN AND DETAILS S5 ROOF FRAMING PLAN S6 KITCHEN ROOF SECTIONS AND DETAILS ELECTRICAL 1A 1.01 LEVEL 1 & LEVEL 2 FLOOR PLANS 1A 1.02 LEVEL 3 & LEVEL 4 FLOOR PLANS 1A 4.01 LEVEL 1 & LEVEL 2 REFLECTED CEILING PLANS 1A 4.02 LEVEL 3 & LEVEL 4 REFLECTED CEILING PLANS PROJECT TEAM: ARCHITECT: K. H. WEBB ARCHITECTS 710 W. LIONSHEAD CIRCLE, UNIT A VAIL, CO 81657 PH: 970.477.2990 CONTACTS: KYLE WEBB GENERAL CONTRACTOR: SRE BUILDERS P.O. BOX 6376 VAIL, CO 81658 PH: 970.845.6359 CONTACT: STEVE ELICKER STRUCTURAL ENGINEER THE MJ MUELLER CO. INC. PO BOX 2747 VAIL, CO 81658 PH: 970.476.2627 CONTACT: MARK MUELLER INTERIOR DESIGNER: KEN FULK 310 7TH STREET SAN FRANCISCO, CA 94103 PH: 415.285.1164 EXT. 127 CONTACT: KRISTIN SIMMONS BUILDING & CODE INFORMATION UNIT 11 BEFORE AFTER SEE ORIGINAL CONSTRUCTION DOCUMENTS: VAIL'S FRONT DOOR BUILDING E. DOCUMENTS AS PREPARED BY OWNER / DEVELOPER, VAIL RESORTS DEVELOPMENT COMPANY AVON, COLORADO. ARCHITECT OF RECORD 4240 DENVER, CO. PROJECT NO: 20693.03 , ISSUE ASIE-056 DATED 09.10.07 FOR BUILDING 5 UNIT 11(5C) No. Description Date 06/25/18 UP DN UP A 8 B C 10' - 8" 4' - 2" D E F 3' - 9 1/2" 9' - 10 1/2" 4' - 0"6 5 4 1 10' - 0" 1' - 5 1/2" 12' - 6 1/2" 26' - 0" 190' - 0" 189' - 6" 5' - 6" BATH A LIGHTWELL EGRESS FOYER ELEVATOR MECHANICAL CLOSET 1 DATA ROOM 195' - 0" 189' - 6" 8'-5 5/8" CEILING 8'-6 3/8" CEILING 8'-7 7/8" CEILING NOTE- FLOOR PLAN LAYOUT BASED UPON ORIGINAL DRAWINGS AS PREPARED BY VAIL RESORTS DEVELOPMENT COMPANY AND FIELD MEASUREMENTS. WALL LAYOUT IS TO FRAMING OR CONCRETE. FIELD VERIFY EXISTING FINISHES AND EXACT MEASUREMENTS UPON DEMOLITION OF REMODELED AREAS.ELEC.PANEL3' - 6"6" STEPCHANGE DOOR SWING AS SHOWN WALLS TO BE REMOVED TYPICAL WALLS TO BE ADDED TYPICAL 192' - 4" OFFICE A LOUNGE 2015 IBC SECTION 1030 EMERGENCY ESCAPE AND RESCUE 1030.1 GENERAL. IN ADDITION TO THE MEANS OF EGRESS REQUIRED BY THIS CHAPTER, PROVISIONS SHALL BE MADE FOR EMERGENCY ESCAPE AND RESCUE OPENINGS IN GROUP R-2 OCCUPANCIES IN ACCORDANCE WITH TABLES 1006.3.2(1) AND 1006.3.2(2) AND GROUP R-3 OCCUPANCIES. BASEMENTS AND SLEEPING ROOMS BELOW THE FOURTH STORY ABOVE GRADE PLANE SHALL HAVE AT LEAST ONE EXTERIOR EMERGENCY ESCAPE AND RESCUE OPENING IN ACCORDANCE WITH THIS SECTION. WHERE BASEMENTS CONTAIN ONE OR MORE SLEEPING ROOMS, EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE REQUIRED IN EACH SLEEPING ROOM, BUT SHALL NOT BE REQUIRED IN ADJOINING AREAS OF THE BASEMENT. SUCH OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC WAY, OR TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY. SEE BUILDING CODE FOR ACTUAL TEXT AND ADDITIONAL INFORMATION INCLUDING BUT NOT LIMITED TO EXCEPTIONS, TABLES AND FOOTNOTES. RAISE FLOOR AND DOORS IN DATA ROOM AND BUNK ROOM SKI ROOM INFILL AS SHOWN THICKEN WALLS PER INTERIOR DESIGNEROFFICE B BATH B BUILT IN'S PER INTERIOR DESIGNER DRAWINGS 7' - 7 1/2"5 1/2"3' - 0" 3 1/2" 7' - 7 1/2" NEW BATHROOM IN BASEMENT AREA. COORDINATE REQUIRED PLUMBING PENETRATIONS AND DRAIN LINES AS REQUIRED IN EXISTING SLAB. COORDINATE VENTING TO EXISTING SYSTEM ABOVE. 4' - 6 1/2"3 1/2"12' - 8" 3 1/2" 3' - 0" 3 1/2"3' - 1" 3 1/2"8' - 2" 4' - 5"9"7' - 9 1/2" PROVIDE FRESH AIR AND EXHAUST MECHANICAL VENTILATION IN ALL ROOMS OF LEVEL 1 EXISTING WALLS TO REMAIN TYPICAL 0' 1' 4' 8' 16' 2' 1/4" = 1'-0"1 LEVEL 1 FLOOR PLAN Project number Date Drawn by k . h . w e b ba r c h i t e c t s . p c710 WEST LIONSHEAD CIRCLE . VAIL SPA CONDOMINIUMSUNIT A . VAIL . COLORADO 81657970.477.2990 970.477.2965(F)A100 LEVEL 1 FLOOR PLAN 000000CHALETS THE LODGE ATVAIL UNIT 11BVAIL 03.06.18 CGM No. Description Date 06/25/18 UP DN A 8 B C D E F 6 5 4 1 205' - 0"205' - 0" FOYER CORRIDOR BEDROOM A BATH A LAUNDRY A JR MSTR CLOSET JR MSTR BATH JUNIOR MASTER CLOSET A PATIO ON GRADE 8'-8 1/8" CEILING 8'-6 7/8" CEILING 8'-7 1/2" CEILING 8'-2 3/8" CEILING 7'-8 1/2" CEILING SOFFIT 7'-9 5/8" CEILING 8'-7 1/4" CEILING 8'-7 1/4" CEILING SOFFIT 7'-8" CEILING 7'-8 3/8" CEILING 8'-6 7/8" CEILING 7'-10 3/8" CEILING ELEVATOR REMOVE EXISTING TUB AND SHOWER AND REPLACE PER INTERIOR DECORATOR DRAWINGS WINDOW TO BE ADDED EXISTING WALL TO BE REMOVED EXISTING WALLS TO REMAIN TYPICAL Project number Date Drawn by k . h . w e b ba r c h i t e c t s . p c710 WEST LIONSHEAD CIRCLE . VAIL SPA CONDOMINIUMSUNIT A . VAIL . COLORADO 81657970.477.2990 970.477.2965(F)A101 LEVEL 2 FLOOR PLAN 000000CHALETS THE LODGE ATVAIL UNIT 11BVAIL 03.06.18 CGM 1/4" = 1'-0"1 LEVEL 2 FLOOR PLAN No. Description Date 06/25/18 UP DN A 8 B C D E F 6 5 4 1 215' - 0" FAN COIL ROOM CORRIDOR BEDROOM B LAUNDRY B MSTR CLOSET BATH B MSTR BATH MASTER BEDROOM CLOSET B DECKAIR VENT8'-7 1/2" CEILING 8'-7 1/2" CEILING 8'-7 1/2" CEILING 7'-5 7/8" CEILING 3'-7 5/8" CEILING 8'-7 1/4" CEILING 8'-7 3/8" CEILING SOFFIT 7'-7 1/2" CEILING SOFFIT 7'-8" CEILING 7'-6 5/8" CEILING 215' - 0" REMOVE EXISTING TUB AND SHOWER AND REPLACE WITH WET ROOM PER INTERIOR DECORATOR DRAWINGS WINDOW TO BE ADDED REMOVE ANGLED WALL WALLS TO BE ADDED EXISTING WALLS TO REMAIN TYPICAL Project number Date Drawn by k . h . w e b ba r c h i t e c t s . p c710 WEST LIONSHEAD CIRCLE . VAIL SPA CONDOMINIUMSUNIT A . VAIL . COLORADO 81657970.477.2990 970.477.2965(F)A102 LEVEL 3 FLOOR PLAN 000000CHALETS THE LODGE ATVAIL UNIT 11BVAIL 03.06.18 CGM 1/4" = 1'-0" 1 LEVEL 3 FLOOR PLAN No. Description Date 06/25/18 DN UP REF.A 8 B C D E F 6 5 4 1 220' - 0" 225' - 0" DECK DECK ELEVATOR FOYER 8'-11 1/8" CEILING 15'-2 7/8" CEILING 13'-3 1/8" CEILING INFILL PORTION OF STAIRS ENLARGE EXISTING COLUMN WALLS TO BE REMOVED TYPICAL. SEE STRUCTURAL DRAWINGS 3 A103 229' - 4" BBQ NEW WOOD FINISH ON STAIRS NEW HANDRAIL TYPICAL NEW STONE FLOOR FINISH REPLACE STONE FINISH AND METAL ENCLOSURE PER INTERIOR DESIGNER GENERAL NOTES -NEW WOOD FLOOR PER INTERIOR DESIGNER. -REFINISH WOOD CEILING. KITCHEN CEILING TO MATCH -RECONFIGURE LIGHTING AND SPEAKERS. REFINISH PER INTERIOR DESIGNER PETE'S PERCH 3' - 0" SEE REFLECTED CEILING PLAN FOR HEIGHTS KITCHEN GREAT ROOM NEW STAIR NEW LOFT ABOVE ENTRY EXISTING WALLS TO REMAIN TYPICAL 8 C D E F 6 5 3 A103 REVERSE SWING OF FRONT DOOR EXISTING CLOSET WALLS TO BE REMOVED TYPICAL WALLS TO BE ADDED TYPICAL MOVE POWDER ROOM TO ENTRY LEVEL FOYER EDGE OF FLOOR ABOVE EXISTING WALLS TO REMAIN TYPICAL POWDER LEVEL 4 225' - 0" BEARING 233' - 9 1/2" 8 6 5 LEVEL 3.5 220' - 0" 4' - 4"NEW STAIRS TO PETE'S PERCH PER PLAN NEW DROPPED CEILING AT KITCHEN SEE STRUCTURAL DRAWINGS LEVEL 4.5 229' - 4" HANDRAIL TO MATCH EXISTING PER CODE NEW FRAMED FLOOR PER STRUCTURAL DRAWINGS UNDERFRAME FLOOR JOISTS TO CONCEAL FLITCH PLATE BEAM RELOCATE POWDER ROOM TO ENTRY LEVEL PROVIDE PLUMBING ALTERATIONS AS REQUIRED EXISTING LEVEL 4 FLOOR FRAMING TO REMAIN EXISTING WALLS TO REMAIN EXISTING ENTRY FLOOR FRAMING TO REMAIN EXISTING ROOF FRAMING TO REMAIN PROVIDE INFILL FRAMING BENEATH NEW STAIRS AND BETWEEN EXISTING FLOOR FRAMING AS REQUIRED Project number Date Drawn by k . h . w e b ba r c h i t e c t s . p c710 WEST LIONSHEAD CIRCLE . VAIL SPA CONDOMINIUMSUNIT A . VAIL . COLORADO 81657970.477.2990 970.477.2965(F)A103 LEVEL 4 FLOOR PLAN 000000CHALETS THE LODGE ATVAIL UNIT 11BVAIL 03.06.18 CGM 1/4" = 1'-0" 1 LEVEL 4 FLOOR PLAN 1/4" = 1'-0"2 LEVEL 3.5 FLOOR PLAN 1/2" = 1'-0"3 POWDER ROOM SECTION No. Description Date 06/25/18 A 8 B C D E F 6 5 4 14" / 12" 4" / 12"4" / 12"4" / 12"3 A103 FLAT CEILING 9'-3 5/8" CEILING HEIGHT (F.V.) 11'-8 7/8" CEILING HEIGHT (FIELD VERIFY) FLAT CEILING4" / 12"REVISE CEILING FRAMING PER STRUCTURAL DRAWINGS EXISTING WALLS TO REMAIN TYPICAL RAISE BEAM PER STRUCTURAL DRAWINGS FIELD COORDINATE ARCHITECTURAL WALL INFILL WITH ARCHITECT AND INTERIOR DESIGNER AT TIME OF CONSTRUCTION Project number Date Drawn by k . h . w e b ba r c h i t e c t s . p c710 WEST LIONSHEAD CIRCLE . VAIL SPA CONDOMINIUMSUNIT A . VAIL . COLORADO 81657970.477.2990 970.477.2965(F)A150 LEVEL 4 RCP 000000CHALETS THE LODGE ATVAIL UNIT 11BVAIL 03.06.18 CGM 1/4" = 1'-0"1 LEVEL 4 RCP No. Description Date 06/25/18 06/25/18 06/25/18 06/25/18 06/25/18 06/25/18 06/25/18