HomeMy WebLinkAboutB17-0333_caement performance rating_1503496860.pdf SPECIFICATIONS AND TECHNICAL MANUAL PERFORMANCE RATINGS AND TESTING DATA CASEMENT AND FIXED WINDOWS PERFORMANCE TEST RESULTS Air Water Ylind Load Performance Forced Entry i Tightness Tightness Resistance Grade operating krrcc Resistance i'it- DIP25.40'• Design Pressure Air Infiltration DP25-40” DP25 40" DP25-40" Passed Grade 10 t 06 SCFMIFT2 i�'a CAN/CSA A2 B5 C2 Passed F10 A440-00 AAMAIWDMAI Class LC PG40 srze Class LC PG40 size Class LC•PG40 size CSA 10111 5 21 tested 40 x 80 tested 40 x B0 tested 40 x BO Passed Grade 10 A4aD-as 'Air Infiltration rates are the flow of air which passes through fenestration products.These values are obtained through the Hallmark Certification program and tested according to AAMAIWDMAICSA 101/1.5.2/A440-08 or 10111.5.2JNAFS.02 The,maximum allowable air infiltration s 0 30 cfm)ftl. •'OP/PG ratings dependent on unit configuration and size Please refer to Casement Section of this Spec and Tech Manual for details THERMAL AND SOLAR HEAT GAIN PERFORMANCE CASEMENT AND FIXED WINDOWS Therrial Performance V1lues Solar HQ 11.G111 Cacfticient linit AvErage"ll"Fdrtilr iSHEC! High'% High- GAS FILL P Aire Perfom�iance"' Aire Perfcrance Blend. Blew' 'INTERNAL GRILLES: (FDL) 0withoutfwhwithout/with w#t out�with wig �with Clear _421.43 .411.41 .51 1.46 .51 1.46 Li-iHigh- .31 1.32 .281.29 .281.25 .271.25 CL Performance Glass High v Performance .321.33 .291.30 .171.16 .171.15 Sun Glass High Performance .31 1 3 2 .251.29 .191.17 .181.17 Smar1Sun^' 1 An argon gas blend sealed between the glass to help inhib t the transfer of energy(heat or cold). 2 Any unit used in high altitude should utilize a capillary breather tube For such units,the gas fill is regular air Numbers based on FR,GBG may vary st ghtly 1 September 2012 CONFIDENTIAL Technical Data 8-27 SPECIFICATIONS AND TECHNICAL MANUAL PERFORMANCE RATINGS AND TESTING DATA CASEMENT AND FIXED WINDOWS, cont. GLASS OPTICAL PERFORMANCE CHARACTERISTICS CASEMENT AND FIXED WINDOWS Shading Visible Light llElravir>'rt Cucfficicnt Transmittance Light (SC) (VT) Transmittance Clear .89 .82 58 High. Performance' .48 .72 .16 Glass GLASS TYPE High- Performance .29 .40 .16 Sun Glass High Performance .31 .65 .05 SmartSun OTHER TEST DATA CASEMENT AND FIXED WINDOWS Relative Ii.It ("Fi tat' RLLitive Ha:•Lty 1 I, y,rrf rc Bru.11. ,1 tiiiticn f.tn;sttne Fa r: Gla,s •:npc;a:. . center&glass centerof glass center ofglast cerirr.ofglass Clear 186 .48 39% 44 Nig• Performance" 99 .25 61% 55. Glass GLASS TYPE High- Performance 62 .25 61% 55' Sun Glass HA. Performance 66 .24 61% 56" SmartSunni -Center of glass"values are generally lower than whole unit values,and are useful ONLY for comparing glass performance,not window performance. SOUND TRANSMISSION 5TC (ITC High-Performance 30 24 GLASS TYPE High-Performance 32 27 TeniperedlLaminate 8-28 Technical Data CONFIDENTIAL September 2012