Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
F18-0035_approved documents_1528751719.pdf
75 South Frontage Road Fire-Construction Permit West, TOWN OFVAIL F18-0035 Vail,CO 81657 Issued: 06/11/2018 TOWN of VAIL(0. Office:970.479.2139 InspectionLine:970.479.2149 Property Information Address: 4273 COLUMBINE DR(210112207011)(210112207011 ) Unit#: ParcelNumber: 210112207011 LegalDescription: Subdivision:BIGHORN 3RD ADDITION Block:9 Lot:16 Contacts ContactType:Applicant Full Name:Clint Janssen Address: P.O.Box 1055 P.O.Box 1055 Vail,CO 81658 Phone: 9709145014 ContactType:PropertyOwner Full Name:RS2 LLC Address: Phone: None Contractor Contractor Type:Fire Protection Company: Vail Valley Fire SprinklerCorp State License#:CO-491 Phone: 970-914-5014 Projectlnformation ProjectName:RS2 LLC Residence2017 ProjectDescription: Install new and residential fire sprinklersystem per all interanational and local codes.Duplex EAST side. Fees Paid Account#:001-0000.31111.04 Fire SuppressionPermitFee Fee Amount: $765.00 Accounl#:001-0000.21123.00 Fire Suppression ReviewFee Fee Amount: $432.00 TotalPaid: $1,197.00 Conditions Issued By:Town of V ailFire and EmergencyServices Department NOTICE: By issuance of this Permitthe applicantagrees to complyto all Titles of the Townof Vail Code and all applicable State and Federal law.Failure to do so will void this Permit and the applicantshall forfeitall applicable fees. VAIL VALLEY FIRE SPRINKLER CORPORATION VAIL VALLEY FIRE SPRINKLER CORP. 57 HEREFORD LANE EDWARDS, CO 81632 PH: (970)914-5014 COLUMBINE DRIVE EAST DUPLEX 4273 COLUMBINE DRIVE VAIL, CO 81657 5/15/2018 HYDRAULIC CALCULATIONS TFTPTD 'r r r FIRE PROTECTION DESIGN,INC. 13147 BIRCH WAY,THORNTON,CO 80241(303)920.6941 PAUL D.HUBBARD-NICET III-#108221 Hydraulic Calculations for P rojectName: COLUMBINE DRIVE EAST DUP LEX Location:4273 COLUMBINE DRIVE,VAIL,COLORADO 81657, Drawing Name: 180501 East.cad Calculation Date:5/15/2018 Design Remote Area Number: 1 Occupancy Classification: Residential Density: 0.100gpm/ft2 Area of Application: 239.24ft2(Actual 239.24ft2) Coverage per Sprinkler: 196.00ft2 Type of sprinklers calculated: Sidewall No.of sprinklers calculated: 2 Type of System: Volume of Dry or PreAction System: N/A In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 39.97 @ 102.221 Water Supply Information: for Node: 1 Date: 5/9/2018 Location: Source: VAILVALLEY FIRE SPRINKLER Name of Contractor: VAIL VALLEY FIRE SP RINKLERCO Address: 57 HEREFORD LANE,EDWARDS, CO 81632 P hone Number: (970)914-5014 Name of designer: PAULHUBBARD. Authority Having Jurisdiction: TOWN OF VAIL Notes: L,©M.E.P.CAD, Inc. i���AutoSPRINK® 12 v12.1.1.0 1 5/15/2018 9:50:33AM Page 1 4(; 1 Hydraulic Summary J Job Number:180501 EAST-RemoteArea 1 ReportDescri•tion:Residential 1 Job Job Number Design Engineer 180501 EAST PAUL HUBBARD. Job Name: State Certification/License Number COLUMBINE DRIVE EAST DUPLEX 108221 Address 1 AHJ 4273 COLUMBINE DRIVE TOWNOF VAIL Address 2 Job Site/Building VAIL,COLORADO 81657 Address 3 Drawing Name 180501 East.cad System 1. RemoteArea(s) Most Demanding Sprinkler Data Occupancy Job Suffix 4.2 K-Factor 19.60 at 21.778 Residential RemoteArea 1 Hose Allowance At Source Density Area of Application 0.00 0.100gpm/ft2 239.24ft2(Actual 239.24ft2) Additional Hose Supplies Number Of Sprinklers Calculated Coverage Per Sprinkler Node Flow(gom) 2 196.00ft2 Total Hose Streams 0.00 System Flow Demand Total Water Required(Including Hose Allowance) 39.97 39.97 Maximum Pressure Unbalance In Loops 0.000 Maximum VelocilyAbove Ground 14.67 between nodes 10 and 11 Maximum Velocity Under Ground 6.15 between nodes 1 and 2 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 51.70gal Supplies Hose Flow Static Residual Flow Available TotalDemand Required Safety Margin Node Name (gpm) (psi) (psi) @ (gpm) (psi) @ (gpm) (psi) (psi) 1 Water Supply 120.000 80.000 1245.00 119.931 39.97 102.221 17.710 Contractors Contractor Number Contact Name Contact T itle 028 CLINT JANSSEN Name of Contractor. Phone Extension VAIL VALLEY FIRE SPRINKLER CO (970)914-5014 Address 1 FAX 57 HEREFORD LANE Address 2 E-mail EDWARDS,CO 81632 blazeinvail@aol.com Address 3 Web-Site ©M.E.P.CAD,Inc. AutoSPRINK®12 v12.1.1.0 5/15/2018 9:51:08AM Page 1 Hydraulic Graph Job Name: COLUMBINE DRIVE EAST DUPLEX N 1.85 RemoteArea Number: 1 Date:5/15/2018 150 Water Supply Summary Sheet 135 Node: 1 _Available Supply 120—Static Pressure 120.000 39.97 @ 119.931 105-39.97 @ 102.221 90 1245.00 @ 80.000 2 75 a` 60-System demand curve E 45 30 15 J 0 -um m u m 111111 1 1 1 1 1 1 1 1 1 1 1 1 111111111 111111 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 0250 500 750 1000 1250 1500 1750 2000 2250 2500 Flow-gpm �M ©M.E.P.CAD, Inc. lii% AutoSPRINK®12 v12.1.1.0 5/15/2018 9:50:35AM Page 2 i Summary Of Outflowing Devices 1 Job Number:180501 EAST-RemoteArea1 :t + - Report Description:Residential(1) Actual Flow Minimum Flow K-Factor Pressure Device (qpm) (qpm) (K) (psi) Ets Sprinkler 101 19.60 19.60 4.2 21.778 Sprinkler 102 20.37 19.60 4.2 23.513 b Most Demanding Sprinkler Data E,©M.E.P.CAD,Inc. In AutoSPRINK®12 v12.1.1.0 5/15/2018 9:50:36AM Page 3 Job Name: COLUMBINE DRIVE EAST DUPLEX Remote Area Number: 1 Date: 5/15/2018 Supply Analysis Static Residual F low Available Total Demand Required Pressure Node Name (psi) (psi) C° (gpm) (psi) @ (gpm) (psi) 1 Water Supply 120.000 80.000 1245.00 119.931 39.97 102.221 Node Analysis Node Number Elevation(F oot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 1 -0-0 Supply 102.221 39.97 101 33-8 Sprinkler 21.778 19.60 102 32-5 Sprinkler 23.513 20.37 2 -1-0 97.423 3 0-6 96.737 4 5-10 73.705 5 8-9 72.166 6 8-9 69.130 7 9-6 65.892 8 27-0 53.949 9 21-6 52.715 10 21-6 52.193 11 21-6 33.394 12 32-5 24.438 13 32-5 23.228 LM,©M.E.P.CAD, Inc. 415 AutoSPRINK®12 v12.1.1.0 5/15/2018 9:50:37AM Page 4 Job Name: COLUMBINE DRIVE EAST DUP LEX Remote Area Number: 1 Date:5/15/2018 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) Length) Fitting Pf Friction Elev Pe ( ) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. I (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. (See 1-2 150 21.778 Route 1 101 33-8 4.2 19.60 '/4 Sprinkler, Notes) 2-0 0.521 13 32-5 19.60 0.8110 3-2 0.290477 0.930 E(2-0) 13 32-5 1 (See 4-0 150 23.228 Notes) 11-0 0.080687 Tr(3-0),T(8-0) 12 32-5 19.60 1.0550 15-0 1.210 12 32-5 20.37 1 (See 10-11 150 24.438 Notes) Flow(q)from Route 2 3-0 4.749 - 0.301480 2E(-0.000),E(3-0) 11 21-6 39.97 1.0550 13-11 4.207 11 21-6 1 (See 31-4 150 33.394 Notes) 31-0 0.301480 4Tr(3-0),E(3-0),2T(8-0) 10 21-6 39.97 1.0550 62-4 18.799 10 21-6 11/4 (See 2-2 150 52.193 Notes) 6-0 9 21-6 29.46 1.2910 8-2 0.064139 0.522 - 2E(3-0) 9 21-6 1% (See 162-9 150 52.715 Notes) 7-0 5.527 0.064139 2E(-0.000),T(7-0) 6 8-9 29.46 1.2910 169-9 10.888 6 8-9 10.51 11/4 (See15-11 150 69.130 Flow(q)from Route 3 Notes) 11-0 0.112794 - 2Tr(2-0),T(7-0) 5 8-9 39.97 1.2910 26-11 3.036 5 8-9 11/2 (See 2-11 150 72.166 Notes) 3-0 1.247 - 0.049797 - BOR,f(-0.000),Tr(3-0) 4 5-10 39.97 1.5270 5-11 0.293 4 5-10 11/2 (See 5-4 150 73.705 Notes) 16-0 2.325 0.049797 3Tr(3-0),BFP(-4.643), 3 0-6 39.97 1.5270 21-4 20.706 f(-0.000),P RV(-15.000), BaIV(7-0) 3 0-6 2 1-6 150 96.737 0.666 2 -1-0 39.97 2.0090 0.013091 1-6 0.020 2 -1-0 2 (See 122-11 150 97.423 Notes) 21-0 -0.434 0.036345 2E(5-0),T(10-0), GV(1-0),S 1 -0-0 39.97 1.6290 143-11 5.232 /,,©M.E.P.CAD,Inc. di AutoSPRINK®12 v12.1.1.0 1 5/15/2018 9:50:38AM P age5 Job Name: COLUMBINE DRIVE EAST DUP LEX Remote Area Number: 1 Date:5/15/2018 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) Length) Fitting Pf Friction Elev Pe ( ) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. 0.00 102.221 Hose Allowance At Source 1 39.97 Total(Pt) Route 1 102 32-5 4.2 20.37 1 (See 2-8 150 23.513 Route 2 Notes) Sprinkler, 8-0 12 32-5 20.37 1.0550 0.086618 T(8-0) 10-8 0.925 24.438 Total(Pt) Route 2 8 27-0 1 (See 167-6 150 53.949 Route 3 Notes) 3-0 7.598 0.025475 2E(-0.000),E(3-0) 7 9-6 10.51 1.0550 170-6 4.344 7 9-6 1 (See 62-4 150 65.892 Notes) 52-0 0.325 0.025475 2T(8-0),7Tr(3-0),5E(3-0) 6 8-9 10.51 1.0550 114-4 2.913 69.130 Total(Pt) Route 3 10 21-6 1 (See 72-0 150 52.193 Route4 Notes) T(8-0) 91-0 -2.396 0.025475 4T(8-0),10E(3-0),7Tr(3-0) 8 27-0 10.51 1.0550 163-0 4.152 53.949 Total(Pt) Route 4 LHS,©M.E.P.CAD,Inc. di AutoSPRINK®12 v12.1.1.0 1 5/15/2018 9:50:38AM P age6 Job Name: COLUMBINE DRIVE EAST DUP LEX Remote Area Number: 1 Date:5/15/2018 Equivalent Pipe Lengths of Valves and Fittings(C=120 only) T—IC Value Multiplier II Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor ( Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP BackflowPreventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DP V Dry P ipeValve E 90°Elbow EE 45°Elbow Eel 11'/4° Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection _ fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flq Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pumpin P2 Pump Out PIV PostIndicating Valve P O Pipe Outlet P rV P ressureRelief Valve P RV P ressureReducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler _ St Strainer T Tee Flow Turn 90° Tr Tee Run _ U Union WirF Wirsbo WMV Water Meter Valve Z Cap - LHS,©M.E.P.CAD,Inc. di AutoSPRINK®12 v12.1.1.0 1 5/15/2018 9:50:38AM P age7 VAIL VALLEY FIRE SPRINKLER CORPORATION 57 HEREFORD LANE EDWARDS, CO 81632 PH: (970)914-5014 COLUMBINE DRIVE EAST DUPLEX 4273 COLUMBINE DRIVE VAIL, CO 81657 5/15/2018 EQUIPMENT SUBMITTAL r*y* FIRE PROTECTION DESIGN,INC. 13117 BIRCH WAY,THORNTON,CO 80241(303(920-0941 PAUL D.HUBBARD-NICET III-#108221 WorldwideFire Protectionrtijci7 Contacts www.tyco-fire.com Products RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and D r yPipe Systems General The Series LFII Residential Concealed Pendent Sp rinklers (TY3596) has Description been designed with heat sensitivity and water distribution characteristics TYCO RAPID RESPONSE Series LFII proven to help in the control ofresiden- - Residential 4.9K Concealed Pendent tial fires and to improve the chance for Sp rinklers (TY3596) are decorative, occupants to escap eor be evacuated. fast response,fusiblesolder sp rinklers The Series LFII Residential Con- 0111111 � designed for use in residential occu- cealed Pendent Sp rinklers(TY3596) p ancies such as homes, apartments, are ship p ed with a Disposable Pro- dormitories,and hotels. tective Cap. The Protective Cap is The cover p late assembly conceals temp orarily removed for installation, the sp rinkler operating components and then it can be rep laced to help above the ceiling.The flat profile of the p rotectthe sprinkler while the ceiling NOTICE cover p lateprovides the op timumaes is being installed or finished. The tip of thetically ap p ealingsp rinkler design. the Protective Cap can also be used The Series LFII Residential Concealed In addition, the concealed design of to mark the center of the ceiling hole Pendent Sprinklers(TY3596)described the Series LFII Residential Concealed into p laster board, ceiling tiles, etc. herein must be installed and main- Pendent Sprinklers(TY3596)provides by gently pushing the ceiling p roduct tained in compliance with this docu- 1/2 inch(12,7 mm)vertical adjustment. against the Protective Cap.When the ment and with the applicablestandards This adjustment provides a measure of ceiling installation is complete the Pro- of the National Fire Protection Associa- flexibility when cutting fixed sprinkler tective Cap is removed and the Cover tion(NFPA),in addition to the standards drops. Plate Assembly installed. of any authorities having jurisdiction. Failure to do so may impair the perfor- The Series LFII Residential Concealed Dry Pipe System Application mance of these devices. Sprink lers are intended for use in the The Series LFII Residential Concealed following scenarios: Pendent Sprinklers offers a laboratory The owner is responsible for main- approved option for designing dry p ip e taining their fire protection system • wet and dry p ip eresidential sp rin- residential sprink lersystems,whereas, and devices in proper operating con- kler systems for one-and two-fam- most residential sprink lers are lab ora- dition.Contact the installing contrac- ily dwellings and mobile homes per tory approved for wet systems only. tor or product manufacturer with any NFPA 13D questions. Through extensive testing, it has been • wet and dry pipe residential sprinkler determined that the number of design Sprinkler systems for residential occupancies sp rinklers(hydraulic design area) for p up to and including four stories in the Series LFII Residential Concealed height p erNFPA 13R Pendent Sp rinklers (TY3596) need Identification • wet and dry p ip esprink ler systems not be increased over the number of w for thearesidentialrypepinker s any design sp rinklers (hydraulic design Number (SIN) Occup ancyp erNFPA r3 area)as sp ecifiedforwet pipe sprinkler systems,as is accustomedfordensity/ TY3596 area sp rinkler systems designed per NF PA 13. Consequently,the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non-water filled pipe in IMPORTANT addition to not having to increase the Always refer to Technical Data number of design sprinklers(hydraulic Sheet TFP700 for the "INSTALLER design area)for systems designed to WARNING" that provides cautions NFPA 13, 13D, or 13R. with respect to handlingand instal- lation of sprinklersystemsand com- ponents. Improper handling and installation can permanentlydamage a sprinkler system or its compo- nents and cause the sprinklerto fail to operate in a firesituation or cause it to operate prematurely. Page 1 of 6 FEBRUARY 2015 TFP442 TFP442 Page 2 of 6 BODYf If SEALING WRENCH (1/2" NPT) ASSEMBLY RECESS _�, �1 ���""\ CAP I r'�/ ,`,�ir� ' SPRINKLER ��IWRENCHING thit AREA SADDLEger SUPPORT / 5 PUSH WRENCH COMPRESSION IN TO ENSURE CUP WITH SCREW n ENGAGEMENT ROLL FORMED I WITH SPRINKLER THREADS WRENCHINGAREA — - LEVER FIGURE2 D R W-TYPE 18 GUIDE ISPRINKLER WRENCH PIN 1 m F J m 1 1 SOLDER LINK ELEMENT GUIDE PIN HOUSING _ DEFLECTOR (OPERATED DEFLECTOR POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO I I RETAINER SUPPORT THREAD CUP UNTIL ) I DIMPLES MOUNTING ls O O I. SURFACE IS FLUSH WITH CEILING EJECTION SPRING / - SOLDER' COVER PLATE/RETAINER COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENTSPRINKLER(TY3596) 2-1/2" DIA. SPRINKLER- (63,5mm) 1/2" (12,7 mm) FACE OF SUPPORT CUP 1/2" THREADED SPRINKLER -/ ASSEMBLY NPT ADJUSTMENT FITTING ' OPERATED �' _ .. 1k/ SPRINKLER i —1 7/8"t1/4„ COVER JJ PLATE I (47,6 mm_ RETAINER 1/8" GAP ±6,4 mm) (3,2 mm) - II m _ I .--_-__-- COVER- SPRINKLER- 7/8 (22,2mm) IPII RETAINER SUPPORT CUP MOUNTING 1-1/8" (28,6 mm) ASSEMBLY ASSEMBLY 3/16 SURFACE , LI (4,8 mm) -���� 3-3/16" DIA. DISPOSABLE DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER(TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP442 Page 3 of 6 Technical Design Criteria Dry Pipe System Water Delivery When using the Series LFII Residen- Data tial Concealed Pendent Sp rinklers TYCO RAPID RESPONSE Series LFII (TY3596)in dry pipe sprinkler systems, Residential Concealed Pendent Sp rin- the time for water delivery must not Approvals klers(TY3596)are UL and C-UL Listed exceed 15 secondsforthe most remote UL and C-UL Listed for installation in accordance with this NYC Approved under MEA 44-03-E-2NSF operating sprinkler. Certified to NSF/ANSI 61 section. The TYCO RAPID RESPONSE Series LFII Note: When conditions exist that are Obstruction to Residential Concealed Pendent Sp rinklers outside the scope of the provided cri Water Distribution are only Listed with the Series LFII Con- feria,ref erto the Residential Sprinkler Sprink lers are to be located in accor cealed Cover Plates having a facto ry-ap- Design Guide TFP490 for the manu- dance with the obstruction rules of p liedfinish. facturer's recommendations that may NFPA 13D, 13R, and 13 as applicable Cover Plates can be ordered by following be acceptable to the authority having for residential sprinklers as well as with the instructions in the Ordering Procedure jurisdiction. the obstruction criteria described within section. the Technical Data Sheet TFP490. Maximum Working Pressure System Types Operational Sensitivity 175 p si(12,1 bar) Per the UL Listing, wet p ip eand dry The sprink lers are to be installed rela- p ip esystems may be utilized. Per the p Discharge Cp,efficient C-UL Listing, only wet p ip esystems tive to the ceiling mounting surface as K=4.9 gp m/p SI' (70,6 Ipm/bar1t2) may be utilized. shown in Figure 3. TemperatureRating Refer to Technical Data Sheet TFP485 Sprinkler Spacing 160°F (71°C)Sp rinklerwith about the use of residential sprinklers in The minimum sp acing between sp rin- 139°F (59°C)Cover Plate residential dry p ip systems. klers is 8 feet (2,4 m). The maximum Vertical Adjustment CeilingTypes sp acing between sp rinklers cannot 1/2 inch(12,7 mm) yp exceed the length of the coverage area Smooth flat horizontal, or beamed, or n hydraulically sloped,in accordance with the 2013 (Ref.Table A or B) being ydraulicall y Refer to Ordering Procedure section. Edition of NFPA 13D, 13R, or 13 as calculated(e.g.,maximum 12 feet fora Physical Characteristics applicable. 12 ft.x 12 ft. coverage area,or 20 feet Body Brass fora 20 ft.x 20 ft.coverage area). Cap Bronze Hydraulic Design The Series LFII must not be used Saddle Brass (NFPAI3D and 13R) in applications where the air pres- Sealing Assembly Beryllium Nickel For systems designed to NFPA 13D sure abovethe ceiling is greater than w/TEFLON or NFPA 13R, the minimum required that below. Down drafts through the Soldered Link Halves Nickel sp rinkler flow rates are given in Support Cup could delay sprinkler Lever Bronze Tables A and B as a function of tern- Compression Screw Brass p erature rating and the maximum operation in a fire situation. Deflector Copper or allowable coverage areas. The Brass sp rinkler flow rate is the minimum Guide Pin Housing Bronze required discharge from each of the Guide Pins Stainless Steel total number of"design sprinklers"as or Bronze specified in NFPA 13D or NFPA 13R. Support Cup Steel The number of "design sp rinklers" Cover Plate Copper specifiedin NFPA13D and 13R forwet Retainer Brass pip esystems is to be applied when Cover Plate designing dry pipe systems. Ejection Spring Stainless Steel Hydraulic Design Operation (NFPA 13) M For systems designed to NFPA 13, the When exp osedto heat from a fire,the number of design sp rink lers is to be Cover Plate,which is normallysoldered the four most hydraulically demanding to the Support Cup at three points,falls sprink lers.The minimum required dis away to expose the sprink lerassemb ly. charge from each of the four sp rinklers At this point the Deflector supported by is to be the greater of the following: the Arms drop sdown to its operated • the flow rates given in Tables A and position. The fusible link of the sp rin- B as a function of temp erature rat- kler assembly is comprised of two link ing and the maximum allowable cov- halves that are soldered together with erage area a thin layer of solder.When the rated • a minimum discharge of temperature is reached, the solder 0.1 gp m/ft.2 over the design area melts and the two link halves sep arate comp rised of the four (4) most allowing the sp rinklerto activate and hydraulically demanding sp rinklers flow water. for actual coverage areas protected by the four(4)sp rinklers The number of design sprinklers sp eci- fied in NFPA13 forwet pipe systems is to be applied when designing dry p ip e systems. TFP442 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure" Maximum Maximum Coverage Ordinary Temp.Rating Area' Spacing 160°F (71°C) Minimum Ft.x Ft. Ft. Deflector to Installation Spacing (m x m) (m) Flow Pressure Ceiling Type Ft. gpm psi (m) (ham) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 13 7.0 inches (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed 16 x 16 16 13 7.0 Ceilings per 8 (4,9 x 4,9) (4,9) (49,2) (0,48) NFPA 13D or Concealed (2 4) 13R,or 13. Installed in 18 x 18 18 17 12.0 beam (5,5 x 5,5) (5,5) (64,3) (0,83) 7/8 to 1-1/8 inches below 20 x 20 20 20 16.7 bottom of (6,1 x 6,1) (6,1) (75,7) (1,15) beam Notes: 1. For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hy draulicdesign criteria are stated. 2. Requirement is based on minimum flow in gpm(Ipm)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to Hy draulicDesign under the Design Criteria section. 3. For NFPA 13 residential applications,the greater of 0.1 gpm/ft?over the design area or the flow in accordance with the criteria in this table must be used. TABLE A W ET PI PE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENTSPRINKLER(TY3596) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure2'3 Maximum Maximum Coverage Spacing Ordinary Temp.Rating Minimum Area Ft 160°F (71°C) Ft.x Ft. Deflector to Installation Spacing (m x m) (m) Flow Pressure Ceiling Type Ft. gpm psi (m) (Ipm) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 14 8.2 inches (4,3 x 4,3) (4,3) (53,0) (0,57) Beamed 16 x 16 16 15 9.4 Ceilings per 8 (4,9 x 4,9) (4,9) (56,8) (0,65) NFPA 13D or Concealed (2 4) 13R,or 13. Installed in 18 x 18 18 18 13.5 beam (5,5 x 5,5) (5,5) (68,1) (0,93) 7/8 to 1-1/8 inches below 20 x 20 20 21 18.4 bottom of (6,1 x 6,1) (6,1) (79,5) (1,27) beam Notes: 1. For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hy draulicdesign criteria are stated. 2. Requirement is based on minimum flow in gpm(Ipm)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to Hy draulicDesign under the Design Criteria section. 3. For NFPA 13 residential applications,the greater of 0.1 gpm/ft?over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT(TY3596) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA TFP442 Page 5 of 6 Installation Step 6. Screw on the Cover Plate Care must be exercised to avoid Assembly until its flange comes in damage before,during,and afterinstal- TYCO RAPID RESPONSE Series LFII contact with the ceiling. lation. Sprinklers damaged by drop- Residential Concealed Pendent Sp rin- Do not continue to screw on the Cover ping, striking, wrench twist/slippage, klers (TY3596) must be installed in Plate Assembly such that it lifts a or the like,must be rep laced. accordance with this section. ceiling p anelout of its normal position. The owner is resp onsible for the General Instructions If the Cover Plate Assembly cannot inspection,testing,and maintenance of Damage to the fusible Link Assembly be engaged with the Mounting Cup their fire protection system and devices during installation can be avoided by or the Cover Plate Assembly cannot in compliance with this document, as handling the sprink ler by the support be engaged sufficiently to contact the well as with the applicable standards Aso- cup only(i.e.,do not app lypressure to ceiling, the Sp rinkler Fitting must be of the National Fire Protection on t the fusible Link Assembly). repositioned. ciation (e.g., NFPA 25), in addition to the standards of any other authorities A 1/2 inch NPT sp rinkleoint should be Care and having jurisdiction.Contact the install- obtained with a minimum to maximum ing contractoror product manufacturer torque of 7 to 14 lbs.-ft.(9,5 to 19,0 Nm). with any questions. Higher levels of torque may distort the Maintenance The owner must assure that the sp rin sp rinklerinlet with consequent leakage TYCO RAPID RESPO NSE Series LFII klers are not used for hanging any or imp airmentof the sprinkler. Residential Concealed Pendent Sp rin- objects and that the sprinklers are only Do not attempt to compensate for klers (TY3596) must be maintained cleaned by means of gently dusting insufficient adjustment in the Cover and serviced in accordance with this with a feather duster; otherwise,non- Plate / Retainer Assembly by under- section. operation in the event of a fire or inad- or over-tightening the Sprinkler. Read- vertent operation may result. just the position of the sprink lerfitting Before closing a fire protection system to suit. main control valve for maintenance Automatic sprinkler systems should be work on the fire protection system insp ected,tested,and maintained bya Step 1. The sprinkler must only be which it controls, permission to shut qualified Inspection Service in accor- installed in the pendent position and down the affected fire protection dance with local requirements and/or with the centerline of the sprinkler per- system must be obtained from the national codes. p endicularto the mounting surface. proper authorities and all personnel Step 2. Removethe Protective Cap. who may be affected by this action must be notified. Step 3. With p ip e thread sealant Absence of a CoverPlate may delay the applied to the pipe threads,and using the W-Type 18 Wrench shown in Figure sprinkler operation in a fire situation. 2, install and tighten the Sp rinkler/ When properly installed, there is a Support Cup Assembly into the fitting. nominal 1/8 inch (3,2 mm) air gap The W-Type 18 Wrench will accept a between the lip of the Cover Plate and 1/2 inch ratchet drive. the ceiling, as shown in Figure 3. This Step 4. Replace the Protective Cap by air gap is necessary for proper op era p ushing it upwards until it bottoms out tion of the sp rinkler by allowing heat against the Support Cup.The Protec flow from a fire to pass below and tive Cap help s p reventdamage to the abovethe Cover Plate to help assure Deflector and Guide Pins during ceiling appropriate release of the Cover Plate installation and/or during application of in a fire situation. If the ceiling is to be the finish coating of the ceiling. It may rep ainted after the installation of the also be used to locatethe center of the Sp rinkler,care must be exercised to clearance hole by gently p ushing the ensure that the new p aintdoes not seal ceiling material against the center point off any of the air gap. of the Cap. Factory p aintedCover Plates must not Note:As long as the protective Cap be repainted.They should be rep laced, remains in place, the system is considif necessary, by factory p ainted ered to be"Out Of Service." units. Non-factory app liedp aint may adversely delay or p revent sp rinkler Step 5. After the ceiling has been operation in the event of a fire. completed with the 2-1/2 inch (63 mm) Do not p ull the Cover Plate relative to diameter clearance hole and in p rep the Enclosure.Separation may result. aration for installing the Cover Plate Assembly, remove and discardthe Pro- Sp rinklers which are found to be tectiveCap,andverifythattheDeflec- leaking or exhibiting visible signs of tor moves up and down freely. corrosion must be rep laced. If the sprinkler has been damaged and Automatic sp rinklers must never be the Deflector does not move up and p ainted,p lated,coated, or otherwise down freely, replace the entire sprinkler altered after leaving the factory. Modi- assembly. Do not attemp tto modify or fied or over heated sprinklers must be rep aira damaged sprinkler. rep laced. Reim bid) Bulletin 048Rev. A Model RFS42 00 Residential Flat Concealed Horizontal Sidewall Sprinkler 00 (SIN RA4835) Coverage to 16 ft.x 20 ft.(4.9mx 6.1m) Features: 1. Flat cover plate(Solid or Perforated) for a flush, concealed wall finish. 2. 4.2(60 metric) K Factor. 3. Sized to fit in a 31/2" or larger stud space even when installed directly in a TorqueSafeTM 90° Sprinkler Head Elbow** and several other common 1/2" and 34" by 1/2" sprinkler fittings. 4. Push-on/pull-off flat cover plate. Application and Installation 5. Sprinkler shipped complete with factory installed The Model RFS42sprinklerisintended for installation nthe protective cap. residential portions of any occupancy in accordance with 6. Sprinkler assembly and cover plate packaged NFPA 13, 13R& 13D.The sprinkler is listed as a Concealed separately. Residential Horizontal Sidewall Sprinkler using a smooth, 7. 14" (3.2 mm)cover plate adjustment. flat, horizontal ceiling. System design and installation re- 8. Cover plate available, either solid or perforated, quirements for other ceiling configurations are described in in a wide variety of colors and finishes. NFPA 13, 13R or 130,as applicable. Listings & Approvals The minimum listed spacing between Model RFS42 sprin- klers is 8 ft(2.4 m). 1. Listed by Underwriters Laboratories Inc. and The low flow RFS42RES sprinklers are specifically engi- UL certified for Canada (cULus). neered to meet the latest residential sprinkler listing stan- UL Listing Category dards(UL 1626 Standard).* Residential Automatic Sprinklers The sprinkler must be installed and properly oriented with the Model G6 Wrench, as follows: UL Guide Number Do not remove the factory installed plastic protective cap VKKW since it is sized to fit inside the G6 wrench. Note that the sprinklercan only mate when the sprinkler's deflectororien- Patents: tation tab(Fig. 1) is aligned with wrench's key-way. The G6 U.S. Patent No.7,353,882, other Patents pending wrench is provided with bubble level pad and TOP mark- Product Description ing,to allow the proper orientation of the horizontal sidewall The Reliable Model RFS42 Concealed Residential Extend- deflector. Final leveling can be done after leak proof joint is ed Coverage Horizontal Sidewall Sprinkler is an attractive, obtained with a minimum to maximum torque of 8 to 18 ft-lbs concealed sprinkler assembly specially sized to fit within (11 to 24 N•m). Leave the protective cap on to protect the a 31/2" or larger stud space.The sprinkler uses a push-on/ sprinklerwhile the wall is plastered, wallpapered or painted. pull-off flat cover plate assembly. The sprinkler assembly is The protective cap must be removed and the listed cover shipped with a protective cap. plate installed prior to the sprinkler system being placed in The flat cover plate is attached to the skirt using 135°F service.A 25/8"(67 mm)diameterhole must be cut in the wall (57°C)ordinarytemperature classification solder. The sprin for the sprinkler assembly to extend through. kler is installed into the sprinkler fitting using the Model G6 Concealed cover plate/cup assemblies are listed only for Sprinkler Wrench. use with specific sprinklers. The use of any otherconcealed When the ambient temperature rises,the solder holding cover plate/cup assembly with the Model RFS42 Horizontal the cover plate melts,allowing the release of this part and Sidewall Sprinkler or the use of this dedicated concealed thus exposing the sprinkler inside to the rising ambient tem- cover plate assembly on any sprinkler with which it is not specifically listed will void all guarantees,warranties, listings perature. and approvals. This sprinkler is listed for a maximum service pressure of .175 psi(12,0 bar). * Effective date 3/14/2008 **Spears Manufacturing Company Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Technical Data: "K"Factor Sprinkler Maximum Orifice Thread Maximum Water Identification Size US Metric Size Ambient Working Pressure Number Approvals Temperature (SIN) 3/3"(9.6mm) 4.2 60 1/2" NPT(R'/z) 100°F(38°C) 175 PSI(12 bar) RA4835 cULus Listed Design Criteria*** Max.Coverage Area Deflector to Ceiling Flow Rate Pressure Temperature Rating Width x Length Dimension ft.x ft. m x m inches mm gpm L/min psi bar Sprinkler Cover 12 x 12 3.6 x 3.6 4-6 102- 152 12 45.4 8.2 0.57 12 x 12 3.6 x 3.6 6- 12 152-305 13 49.2 9.6 0.67 14 x 14 4.3x4.3 4-6 102- 152 12 45.4 8.2 0.57 14 x 14 4.3 x 4.3 6- 12 152-305 14 53.0 11.1 0.78 165°F (74°C) 135°F(57°C) 16 x 16 4.9x4.9 4- 12 102-305 16 60.6 14.5 1.01 16 x 18 4.9 x 5.5 4- 12 102-305 18 68.1 18.4 1.29 16 x 20 4.9 x 6.1 4-6 102- 152 22 83.3 27.4 1.92 16 x 20 4.9 x 6.1 6- 12 152-305 23 87.0 30.0 2.10 ***For NFPA 13 systems calculate for a minimum design density of 0.1 gpm/sf, but in no case go below the Listed Design Criteria Flow Rate and Pressure. Material Data Bronze Sprinkler Body,Spring Closure Cap,Yoke,Lever, Slide Pin,Slide Plate,Deflector,Set Screw Brass Cover Plate,Sprinkler Sleeve,Frame Arms Stainless Steel Push Spring, Ball,Load Screw,Rivet Copper Plated Steel Cover Plate Skirt Nickel Alloy Fusible Element Nickel Alloy coated with PTFE Adhesive Tape Sealing Washer 2"± 1/16"[51MM± 1.6MM] %r Af- CEILING //4 DEFLECTOR ORIENTATION DEFLECTOR ORIENTATION TAB TAB a,�' 4-3/8"TO 12-3/8" f [111 TO 314MM] /�� RECOMMENDED o o WALL HOLE 1111111 MI 1‘200171{W.'1 nil DIAMETER �,. &---------- SII ��� ���- 2-5/8" I I ,„.„. � �R�-4M0'-•"*) g �y!�, [66.7MM] I �__.r 4 PUSH ON/PULL OFF FLAT COVERPLATE TO 1/2"-14 NPT 3-5/16"[84.1MM] DIAMETER FRONT VIEW PUSH ON/PULL OFF FLAT COVERPLATE REMOVED - 3/16"[4.8MM] 1-3/8"±1/16" [34.6MM±1.6MM] *SEE LISTED DESIGN CRITERIA TABLE FOR FLOW RATE AND PRESSURE BASED ON DEFLECTOR TO CEILING DISTANCE. DEFLECTOR IS 3/8"[9.5MM]ABOVE CENTERLINE OF SPRINKLER. 04BFGOIG Fig.1 2. Installation Guide for 31/2" or Larger Stud Space R FS42R esidential Flat Cover Concealed Horizontal Sidewall Sprinkler SIN RA4835 CEILING CENTERLINE 1-3/8" �{ [35MM] ELBOW ,MINIMUM -- / � - -- CENTERLINE CENTERLINE OF 4-3/8"TO 12-3/8"* 2-5/8"[66.7MM] [111 MM-314MM] DIAMETER HOLE IN WALL LOCATE PIPE SUPPORT CLAMP WITHIN 1"[25MM] FROM SPRINKLER FITTING'S INLET = STUD A 048FG010 *SEE LISTED DESIGN CRITERIA TABLE FOR FLOW RATE AND PRESSURE BASED ON DEFLECTOR TO CEILING DISTANCE. DEFLECTOR IS 3/8"[9.5MM] ABOVE CENTERLINE OF SPRINKLER. Fig.2 Front View Attachment Method: Fig. 3: 1. Securely support pipe from adjacent stud. 2. Pipe support clamp shall be located within 1" [25 mm] of sprinkler fitting's inlet lip. 3. The center of the sprinkler fitting shall be located at a horizontal distance of 13/" [35 mm] or more from the stud (Fig. 3). 4. The sprinkler fitting shall be installed so that the rear of the sprinkler is 2" +/- 1/6" from the finished surface of the wall.Verifywall assembly dimensions prior to installation to ensure that the cover plate attaches to the sprinkler and seats against the finished wall surface(Fig. 1). ELBOW — MINIMUM 1-3/8"[35MM] 3-1/8" m,— [79MM] STUD— /.viU////.////.%////////////////1� WALL FINISH MATERIAL DIMENSIONS ON THIS FIGURE ARE BASED ROOM ON A SPEARS TORQUESAFETM 3/4"X 1/2"90° CENTERLINE SPRINKLER HEAD ELBOW(4207-101). 098FC03B DIMENSIONS MUST BE ADJUSTED IF OTHER FITTINGS ARE USED. Fig.3 3. 5. Maintenance Cover Plate Finishesco Model RFS42 Concealed Sprinklers should be inspected Standard Finish and maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammoniaor any other clean- White ing fluids. Remove dust by using a soft brush or gentle Special Application Finishes vacuuming. Replace any sprinkler or cover plate assem- Flat White Paint bly, which has been painted (other than factory applied) or Off White Paint damaged in any way. A stock of spare sprinklers should Black Paint be maintained to allow quick replacement of damaged or Custom Color Paint operated sprinklers. Prior to installation, sprinklers should Bright Brass be maintained in their original cartons and packaging until Bronze Chr used to minimize the potential for damage to sprinklers that Satin Chrome would cause improper operation or non-operation. Once Black Plating operated automatic sprinklers and cover plates cannot be reassembled and reused. New sprinklers of the same size, ")Other colors and finishes are available. Consult factory for details. type and temperature rating must be installed. A cabinet of Note:Paint or any other coatings applied over the factory replacement sprinklers should be provided for this purpose. finish will void all approvals and warranties. Model RFS42 Residential FlatCoverConcealed Horizontal Sidewall Sprinkler Specification Ordering Information Sprinklers shall be a UL listed as residential flat cover Specify: concealed horizontal sprinkler with RFS42 deflector and 1. Model RFS42Residential Sidewall adjustable cover plate for light hazard, interior, non- 2. Cover Plate Type:Solid or Perforated corrosive applications. Sprinklers to be of bronze frame 3. Cover Plate Finish construction with brass cover plate and copper alloy retainerflangeassembly.Watersealassemblyshallconsist Installation Wrench of a Teflon*coated Belleville spring washer and machined Model G6 Sprinkler Wrench brass cup containing no plastic parts.Method of attaching the cover plate to the sprinkler cup shall be a Push-on Installation Aid and Pull-off design allowing a 1/8" cover plate adjustment. A protective plastic cap is included for use during instal Sprinklersshall have a nominal K-factorof 4.2(60 metric), and 1" NPT thread. Sprinkler temperature rating shall lation. be 165°F (74°C)with a cover plate temperature rating of 135°F (57°C). Sprinklers shall be capable of a maximum coverage area of 16 ft. x 20 ft. (4.9 m x 6.1 m), with a minimum lateral spacing of 8 ft. (2.4 m). Rated working pressure shall be 175 psi (12,0 bar).A plastic protective cap shall be provided and factory installed onto the sprinkler cup to protect the sprinkler from damage,which could occur during construction before the cover plate is installed. Cover plate type: [Solid] [Perforated]. Cover plate finish: [White] [Custom Color—specify]. Residential Coverage Concealed horizontal sidewall sprinklers shall be Reliable Model RFS42.SIN RA4835(Bulletin048). *DuPont Registered Trademark The equipment presented in this bulletinis to be installed in accordanceAiththe latestpublished Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or othersimilarorganizations and alsowith the provisions of governmental codes or ordinances wheneverapplicable. Products manufactured and distributed by Reliable have been protecting life and propertyforover90 years,and are installed and serviced bythe most highly qualified and reputable sprinklercontractors located throughout the United States,Canadaand foreign countries. Manufactured b Reliable Automatic Sprinkler Co.,Inc. �s' Recycled ® (800)431-1588 Sales Offices �W Paper Reliable (800)848 6051 Sales Fax (914)829 204 2 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.04/15 P/N 9999970457 NIBCO www.nibco.com AHEAD OF THE FLOW® Revision 3/29/04 e s. All of the advantages found in copper as a metal have been capitalized to the utmost in the manufacture of NIBCO Fittings.Because of the accuracy of construction and design, copper plumbing is more efficient and less expensive. NIBCO manufactures nine general types of fittings:Wrot Pressure;Cast Pressure;Wrot Drainage;Cast Drainage;Flanges; Flared Tube;Threaded Bronze;Insert Fittings for PEX;Barbed Insert Fittings for Polybutylene.Each has its particular place and use and each offers its own advantages when used for the proper service requirement. ALLOY AND FINISH—NIBCO Fittings are made from highest quality raw materials available—Cast Fittings are made from Copper Alloy C84400 which consists of 81% Copper,7% Lead,3%Tin,and 9%Zinc per ASTM Specification B 584.Wrot Copper Fittings are made from commercially pure copper mill products per ASTM Specifications B75 Alloy C12200. NIB CO fittings are produced to meet requirements of applicable standards wherever practicable. NIB CO brand wrot and cast fittings are manufactured in the U.S.A.and Mexico.The manufacturing plants at Stuarts Draft,VA, Nacogdoches, TX and Reynosa, Mexico are registered to ISO 9002 quality standards. Following is suggested phrasing to be incorporated in your specifications or bills of material for Copper Tube Fittings. R WROT SOLDER JOINT FITTINGS—"Wrot Solder Joint Fittings shall be produced to one of the following specifications: 1. Material and workmanship shall be in accordance with ASME/ANSI B 16.22;Wrought Copper and Copper Alloy Solder Joint Pressure Fittings." 2. The dimensional, material and workmanship shall dimensions of Federal Specifications WW-F-406or meet the requirements of MSS SP-104;Wrought ASME Std. B16.24. Copper Solder Joint Pressure Fittings." CLASS 125—Material,workmanship and 3. The dimensional, material and workmanship of dimensions of flanges shall be in accordance with 5"-12" copper fittings shall meet the requirements MSS SP-106. of MSS SP-109 "Welded Fabricated Copper Solder CAST BRONZE THREADED FITTINGS— Joint Pressure Fittings." "Cast Bronze Threaded Fittings shall be in accordance 4. Certified to ANSI/NSF 61. with ANSI/ASME B16.15." CAST COPPER ALLOY SOLDER JOINT FITTINGS POLYBUTYLENE COPPER INSERT TYPE VALVES AND —"Cast Copper Alloy Solder Joint Fittings shall be in FITTINGS—"Wrot Copper Insert Fittings shall be accordance with ANSI Std. 816.18." manufactured per the following specifications: WROT DRAINAGE FITTINGS—"Wrot Drainage MSS SP 103 or ASTM F1380." Fittings shall be in accordance with ASME/ANSI Std. NIBCO Copper Tube Fittings are all produced to above B 16.29." Standards.To simplify,write your specifications to CAST COPPERALLOYSOLDER JOINT DRAINAGE read: "Copper Tube Fittings to be in accordance with FITTINGS—"Cast Copper Alloy Solder Joint Drainage specifications as outlined in NIBCO Catalog c cf 0602." Fittings shall be in accordance with ASME Std. WROT COPPER MEDICAL MEDICAL GAS SYSTEM B16.23." COMPONENTS—Wrot copper fittings that are to be CAST COPPER ALLOY FLARED TUBE FITTINGS—"Cast installed in medical gas applications shall be prepared in accordance with NFPA 99, Health Care Facilities Copper Alloy Flared Tube Fittings shall be in accor- dance with ASME/ANSI Std. B16.26. Gas and Vacuum Systems and the Compressed Gas Association,Pamphlet G4.1. Packaging shall CAST COPPER ALLOY FLANGES AND FLANGED be adequately protective and include labeling that FITTINGS— identifies the preparer and states that the product CLASS 150—Cast Copper Alloy Flanges and has been cleaned and bagged for oxygen or med gas service. Flanged Fittings shall meet the requirements of MSS SP-106 and/or the workmanship and For technical information and dimensions refer to the engineering section contained in this catalog. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 4 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONALOFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com NIBCO www.nibco.com AHEAD OF THE FLOW° Revision 5/12/02 Copper Waterlubecontinued COPPER TUBE -TYPES, STANDARDS,APPLICATIONS, TEMPERS AND LENGTHS Commercially Available Lengths Tube Type Color Code Standard Application Nominal or Standard Sizes Drawn Annealed Type K Green ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 8-inch 20 ft.(6.1m) 20 ft.(6.1m) Fire Protection 10-inch 18 ft.(5.5m) 18 ft.(5.5m) Solar 12-inch 12 ft.(3.7m) 12 ft.(3.7m) Fuel/Fuel Oil Coils: 1/4-inch to 1-inch — 60 ft.(18.3m) HVAC — 100 ft.(30.5m) Snow Melting 11/4-inch&11/2-inch — 60 ft.(18.3m) 2-inch — 40 ft.(12.2m) 45 ft.(13.7m) Type L Blue ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 10-inch 20 ft.(6.1m) 20 ft.(6.1m) Fire Protection 12-inch 18 ft.(5.5m) 18 ft.(5.5m) Solar Fuel/Fuel Oil Natural Gas Coils: 1/4-inch to 1-inch — 60 ft.(18.3m) Liquified Petroleum(LP)Gas — 100 ft.(30.5m) HVAC 11/s-inch&11/2-inch — 60 ft.(18.3m) Snow Melting 2-inch — 40 ft.(12.2m) 45 ft.(13.7m) X Type M Red ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 12-inch 20 ft.(6.1m) N/A Fire Protection Solar Fuel/Fuel Oil HVAC Snow Melting DWV Yellow ASTM B 306 Drain Straight Lengths: 11/4-inch to 8-inch 20 ft.(6.1m) N/A Waste Vent HVAC Solar ACR Blue ASTM B 280 Air Conditioning Straight Lengths: 1/4-inch to 41/2-inch 20 ft.(6.1m) 20 ft.(6.1m)1 Refrigeration Natural Gas Coils: 1/2-inch to 15/2-inch — 50 ft.(15.3m)1 Liquified Petroleum(LP)Gas OXY Type K ASTM B 819 Medical Gas Straight Lengths: 1/4-inch to 8-inch 20 ft.(6.1m) N/A MED Green OXY/MED OXY/ACR TypeL ACR/MED Blue TypeG Yellow ASTM B 837 Natural Gas Straight Lengths: 3/2-inch to 11/2-inch 12 ft.(3.7m) 12 ft.(3.7m)1 Liquified Petroleum(LP)Gas 20 ft.(6.1m) 20 ft.(6.1m)1 Coils: 3/2-inch to 7/2-inch — 60 ft.(18.3m)1 100 ft.(30.5m)1 'Available as special order only. U.S.customaryunits in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONALOFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 81 www.nibco.com SUSPENSION CLAMP FOR CTS PIPING ))557 SERIES EZGIideTM ITEM#SUBMITTE D JOB NAME SPECIFICATION LOCATION Sioux Chief 557 series suspension clamps are to be used where ENGINEER necessary to secure or suspend CTS piping in residential or commercial applications.Tube clamp has a split, ribbed design to allow for use CONTRACTOR after piping is run and to allow pipe to expand and contract. Clamps are PO# TAG compatible with CTS copper, PEX or CPVC tube. Clamps shall be IAPMO certified. 0 INSTALLATION Spread each side of the clamp and position clamp around the tube. • lb \ Use approved nail or screw in both of the provided holes to secure to stud member or structure. MATERIALS 557-2 557F4 F *Standard(ivory): high impact polypropylene E Plenum-safe(orange): polyvinylidene fluoride meets ASTM E8425/50 • with UL 94 V-0 rating 0 O — WORKING TEMPERATURE � � B c Standard(ivory): 140°F continuous; impact resistant to 0°F Plenum-safe(orange): -10°F- 140°F A SAFE WORKING LOAD D� Standard(ivory): 25 lbs. Plenum-safe(orange): 25 lbs. 1/2" and 3/4° models E . DIMENSIONS O O 557-2 557-3 557-4 557-5 557-6 557-7 I A:Tube size CTS 1/2" 3/4" 1" 11/4" 11/2" 2" B:Screw hole to 0.938" 1.108" 1.013" 1.188" 1.363" 1.663" c tube center A C:Overall height 1.703" 1.998" 2.019" 2.332" 2.639" 3.219" D:Overall depth 0.625" 0.675" 0.825" 0.975" 1.025" 1.125" E: Mounting hole 1.206" 1.409" 1.421" 1.827" 1.827" 2.436" D center-lines 1"-2"models F: Mounting tab 0.12" 0.12" 0.12" 0.15" 0.15" 0.15" wall thickness oO G: Hole diameter 0.188" 0.188" 0.188" 0.188" 0.188" 0.188" Made in USA Create Item Number 557-A B e.g.557F3:Plenum-safe 3/4" CTS suspension clamp MATERIAL A SIZE B ❑ —=High-impact polypropylene ❑ 2=1/2"CTS ❑ F =Polyvinylidene fluoride ❑ 3 =3/4"CTS ❑ 4 =1"CTS ❑ 5 =11/4"CTS ❑ 6 =11h"CTS ❑ 7 =2" CTS Sioux Chief Sioux Chief Manufacturing Company I P:1.800.821.3944 I F: 1.800.758.5950 I www.siouxchief.com 10-16 TUBECLAMP FOR CTS PIPING II 559 SERIES ITEM#SUBMITTED JOB NAME SPECIFICATION LOCATION Sioux Chief 559seriestube clamps are to be used where necessary to ENGINEER secure CTS piping in residential or commercial applications. Tube clamp has a split,ribbed design to allow for use after piping is run and to allow CONTRACTOR pipe to expand and contract. Clamps shall be compatible with CTS copper, PO# TAG PEX or CPVC tube.Clamps shall be IAPMO certified. INSTALLATION Spread each side of the clamp and position clamp around the tube. Use approved nail or screw in both of the provided holes to secure clamp to stud member or structure. MATERIALS \s i Standard(ivory): high impact polypropylene ' Plenum-safe(orange): polyvinylidene fluoride meets ASTM E84 25/50 with UL 94 V-0 rating 559-2 SAFE WORKING TEMPERATURES *Standard(ivory): 140°F(continuous); impact resistant to 0°F Plenum-safe(orange): -10°Fto 140°F SAFE WORKING LOAD Standard(ivory): 25 lbs Plenum-safe(orange): 15 lbs 559F6 DIMENSIONS D 5592 559_3 559_4 5595 559_6 5597 A:Tube size (CTS) 1/z" 3/4" 1" 11/4' 11/2" 2" B:Overall height 1.021" 1.275" 1.535" 1.785" 2.034" 2.562" clir A B C: Overall length 2.415" 2.617" 2.821" 3.227" 3.421" 3.836" D:Overall depth 0.624" 0.675" 0.825" 0.975" 1.025" 1.125" F I J [ E: Mounting hole 1.624" 1.827" 2.233" 2.639" 2.843" 3.248" c • center-lines F: Mountingtab .603" .603" 0.12" 0.15" 0.15" 0.15" wall thickness G: Hole diameter 0.188" 0.188" 0.188" 0.188" 0.188" 0.188" E cO Made in USA Create Item Number 559A B e.g.559F3:Plenum-safe 3/a"CTS tube clamp MATERIAL A SIZE B ❑ -=High-impact polypropylene ❑ 2=1/2"CTS ❑ F =Polyvinylidene fluoride ❑ 3 =3/4"CTS ❑ 4 =1"CTS ❑ 5 =11A"CTS O 6 =11/2 CTS ❑ 7 =2" CTS Sioux Chief Sioux Chief Manufacturing Company I P:1.800.821.3944 I F: 1.800.758.5950 I www.siouxchief.com 11-16 101 Loop Hanger for Copper Tube ir • Recommended for the suspension of stationary non-insulated copper tube lines • Conformswith Federal Specification WW-H-171 (Type10), Manufacturers Standardization Society(MSS)SP-58(Type10) RS ,-/ B A OD Material:Steel Finish:Copper Electroplated, Electrogalvanized rOuter Diameter Rod Size Static Load Part Number Pipe Size OD RS A B C F 1010050CP 1/2" 5/8" 3/8" 3 3/16" 1 5/8" 1 9/16" 180 Lb 1010075CP 3/4" 7/8" 3/8" 31/8" 13/8" 13/16" 1801b 1010100CP 1" 11/8" 3/8" 31/8" 1 5/16" 1" 1801b 1010125CP 1 1/4" 1 3/8" 3/8" 3 3/16" 1 1/4" 13/16" 180 lb 1010150CP 1 1/2" 1 5/8" 3/8" 3 5/8" 1 9/16" 15/16" 180 lb 1010200CP 2" 21/8" 3/8" 313/16" 17/16" 5/8" 1801b 1010250CP 2 1/2" 2 5/8" 3/8" 4 7/16" 1 11/16" 9/16" 200 lb 1010300CP 3" 31/8" 1/2" 511/16" 21/2" 15/16" 2501b 1010350CP 3 1/2" 3 5/8" 1/2" 6 7/16" 3" 1 9/16" 300 lb 1010400CP 4" 4 1/8" 1/2" 7 1/8" 3 7/16" 1 3/4" 360 lb 1010500CP 5" 5 1/8" 5/8" 9 1/4" 4 11/16" 2 5/16" 480 lb 1010600CP 6" 6 1/8" 3/4" 11 3/16" 5 3/4" 2 15/16" 630 lb WARNING Pentair productsshall be installed and used only as indicated in Pentair's product instruction sheets and training materials.Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative.Improperinstallation,misuse,misapplication or other failure to completelyfollow Pentair's instructions and warnings may cause product malfunction,property damage,serious bodily injury and death and/or void your warranty. ©2017 Pentair All rights reserved Pentair,CADDY,CADWELD,CRITEC,ERICO,ERIFLEX,ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners.Pentair reserves the right to change specifications without prior notice. It CADDY 0 PENTAIR SAMMYS® HORIZONTALMOUNT SIDEWINDERS° f orW oodnstalls HORIZONTALLY into the side of woodstructures easilyand quickly! I Not less than 2°nominal width • Product Featuresis M. O ° (1-1/2")up to 3-1/2°pipe;not less than 3"(2-1/2")nominal width 4"&5"pipe •No pr a-dr illing equir ed. ___.ter ..�....»�... I—/ A Floor Joist , •Quickto install using the Sammy branch lines.Minimum 3"from t Minimum 2-1/2"fr ombottom for Nut Dr IVerwith an 18V cordless bottomfor main lines.Exception:This drill/driver. r equir emenbhall not apply to 2"or if / thicker nailing str ipsr estingon top of / steel beams. •Saves time fr omtr aditional • methods. I,,, •Reduces installation cost. 1:1 •Made in the U.S.A. 0 0• ti Composite/Truss acur d Consult tr ussmanufactur dor recommended installation point. 1AI "Pr e-dr illingnay be r equir edor Model SWG 25-380(tools available on pg 10) CI Rod Part Screw Ultimate UL Test Box Case Approvals Model Size Number Descriptions Pullout(Ibs) Load(lbs) Qty Qty 1/4" 8018957 SWG 100 1/4 x 1" 622 (Fir) 25 125 _i 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 125 I CL 125 y 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 , 3/8" 8021957 SWG20 1/4x2" 1725 (Fir) 1050 25 3/8" 8073925 SWG20-SS 1/4x2" 1725 (Fir) 850 25 125 #14 SW Red ®. 318" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 Nut Driver I 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 Par t#8114910 VERTICAL HORIZONTAL 1.Insertthe appropriate nut driver into a 3/8"or 1/nortable drill. 1.Insertthe appropriate nut driver into a 3/8'or 1/2"portable drill. 2.Insertthe SAMMYS into the#14(black)nut driver(p/n 8113910).Drill 2.Insertthe SAMMYS into the#14SW(red)nut driver(p/n 8114910).With drill shouldbe in a vertical position. unitin a horizontal position and at a rightangle to the structural member, begin installation. 3.Push the face of the nut driver tightto the member.When the nut driver spins freely on the SAMMYS,stop drill and remove. 3.When the nut driver spins free on the SAMMYS,stop the drill and remove. 4.The SAMMYS is now read yto receive 1/4';3/8", 1/2"ormetric all threadrod,boltstock.(The 1/2'fiequires the#14SWred nut driver) 4.The unitis now readyto receive 1/4",3/8'ormetrical!threadrodor boltstock. Note:When installing DSTR,follow the above instructions, then add retainer nut and torque to 20 f ootlbs.formaximum Note:When installing SWDR,follow the above instructions,then add retainer nut pulloutin puffin steel. and torque t ,,, o 20 footlbs.formaximum pulloutin purlin steel. sssss 1,..,vi Ill el. 1 .,„, , , _ : , 7 , ,,,, 4p; "A., SPECIAL NUT DRIVER SYSTEM:The nut driver slier edesigned with a unique spin-offfeature which pr ovidesa fast and safe installation each time.When the face of the dr ivercomes into contact with the mater ialyou are installing into,continue dr illing until nut dr iverspins free.Installation is then complete.Warranty requires the use of the appropriate nut dr iverfor installations. 5 Tofind a distributornear you,call 800-BUILDEX ' — MODEL— CRD- L Direct Acting CLA-VALTM Pressure Reducing Valve iii— • Meets Requirements of "Reduction of Lead in p 4D CE S P40"4:46.....,„,,,,, °”" o Drinking Water Act" WaterQualty • Sizes: 3/4"• 1" • 1-1/4" • 1-1/2" • 2" • 2-1/2" %'4.0.,5, • Operates in Any Position �- w._ fa • Easy Installation Cla-Val products comply with the • Stainless Steel Trim Standard National Lead Free Mandate Reduction of Lead in / """"' •• Gauge Connections Standard Drinking Water Act" •_ _ _ • All Bronze Body and Cover h,o ,44 s ., • EPDM Disc and Diaphragm F - i 11161P The Cla-Val Model CRD-L Pressure Reducing Valve automatically reduces a higher inlet pressure to a steady lower downstream pressure with our unique design. This valve is an accurate regulator capable of holding downstream pressure to a predetermined amount, regardless of upstream pressure fluctuations. Periodic maintenance consist of regular internal cleaning that is accessed by removing bottom plug. Typical Applications Flow Cla-Val i 90 Series Pressure High '-.--k. [-I le:lucinValv_e_g High rise buildings use CRD-L Pressure Reducing =� Pressure Valves in various water systems (potable water, boiler � P / feed air conditioning, etc.)to control pressure fluctuations y °0 ,,,,between floors. 4mm Isolation i' y='� Valve ` /ef Industrial plants use CRD-L Pressure Reducing Valves -,--. /� between a high pressure supply system and equipment / 9 the requiring lower pressure. Typically CRD-L Pressure Reducing Valves are used at supply connections for water Cla Val CRD-L m heaters,boiler feed water or other process water systems. Lowiik Pressure Municipal water systems use CRD-L Pressure Flow Reducing Valves at service connections in a high Cla-ValCRD-L pressure distribution zone.Depending on flow High (�• / requirements,CRD-L's may be installed in parallel. Pressure '�� One CRD-L provides desired outlet pressure while the second CRD-L handles low flow conditions. If necessary, additional CRD-L's can be added for more flow capacity. Ivo The CRD-L is also ideal for a low flow bypass around a Low larger Cla-Val 90 Series Pressure Reducing Valve. 1 Pressure Isolation Valve 1 Cla-Val CRD-L Valve Operation is) :::;:::„: _...... 1.L _ . . i ._ . - IrAllfr— 4,1 Lil .,. .___-1 ii=....— ...a I I i m Ill 1... ) 4 t„ darri 111A t 7. Flow Condition No Flow Condition When flow begins, the pressure on the underside of the When there is no flow,the downstream pressure increases and diaphragm will be lower than the set-point of the spring acts against the under side of the diaphragm, pulling the valve causing the diaphragm to move the valve seat away from seat up against the valve seal to close the valve. the valve seal allowing flow to occur. As the flow increases downstream,the pressure acting on the spring pushes the diaphragm and the valve seat awayfrom the valve seal to regulate outlet pressure to desired value. Reduced Pressure Falloff Sizing Unlike pilot controlled pressure reducing valves, direct Step One acting valves are subject to "reduced pressure falloff" Determine the following from the application: (RPF). Reduced pressure falloff is the decrease in dow nstream regulated pressure that occurs w hen the flow 1. Inlet pressure and desired outlet pressure increases.When the demand for flow increases,the valve 2. Maximum and minimum flow rate must open wider and wider to permit the flow. The only 3. Allow ablereduced pressure falloff or way the valve can open is for the spring force to be greater maximum velocity based on acceptable noise level than the hydraulic force under the diaphragm (the force trying to close the valve). The downstream pressure Step Two therefore,must "fall off"or decrease before the spring can Determine the pressure differential across the valve by open the valve. All spring actuated direct acting valves subtracting the desired outlet pressure from the inlet pressure.If have similar operating characteristics. there w ill be any fluctuations in the inlet pressure,calculate both high and low differentials.At all times the differential must be at Noise and Velocity Guidelines least 14.5 psi. When the differential is greater than 100 psi, use two valves in series. Noise in waterpiping systems can sometimes be attributed to high velocities of water through the valve seat. In Step Three general, as the water velocity increases, the noise Determine the valve size by using the Valve Capacity Charts on produced by the installation w ill increase. the next page. Start by referring to the valve capacity chart for Where noise levels are important, such as residences, the system's maximum flow rate. Locate the value for the hospitals, or schools, pipeline velocities should be in the maximum allowable reduced pressure falloff for your range of 5 to 10 fps. The chart below shows velocity and application. Select the valve size with a RPF value that is less the corresponding reduced pressure falloff. If these values than the maximum RPF. for falloff are not exceeded, the CRDL w ill produce the If flow demand fluctuates beyond the capacity of one valve,use least amount of noise. twoor more Model CRDL's in parallel.Size one valve to handle the low flow,and the other valve(s)to handle the higher flows. Set the low flow valve to approximately 3-4 psi higher than the other valve(s). Velocity Velocity Delta from Set Point Pressure Falloff psi Guide Chart Set Point,fps 3/4"and 1" 1-1/4" and 1-1/2" 2" 2-1/2" 5.0 6.0 3.5 6.0 8.5 7.5 9.5 6.5 9.5 12.0 10.0 12.5 8.5 12.5 17.0 Valve Capacity Charts System Flow Rate -GPM Sys 112" to 1 1/4 ' 0 10 20 30 40 50 SO 70 F 0 9- 2 5 - To u_ \\\NN `--......, 10 112 zi no 15NN...... c 20 I - 1 /2" 3/4" 1 " 1 1/4" System Few Rate- G PM Sizes 1 1P2' to 2 11/2" 0 25 50 75 100 125 150 175 200 0 i } r : : 15 1F s s I { -1611 -I 1/2" " 2 112" Adjustment Range Spring Description Spring Range PSI/Turn -'ht Green 15-65 PSI 3.5 PSI/Turn Dark Green 25-100 PSI 6 PSI/Turn Blue 80-150 PSI 10 PSI/Turn Specifications Temperature Range Materials Water: to 140°F (70°C) Max Body and Cover: Low Lead Bronze CuZn21Si3P Diaphragm: EPDM Pressure Ratings Maximum Inlet Pressure:400 psi (25 Bar) Disc: EPDM Maximum Outlet Pressure:150 psi (10 Bar) Minimum Differential Pressure:14.5 psi Dimensions (Inches) Dimensions (mm) Size A B C D E Weight Size A B C D E Weight (lbs.) (kgs.) 3/4" 5.60 6.06 2.56 3.12 8.62 4.0 20 143 154 66 80 219 1.8 1" 6.68 6.06 2.56 3.12 8.62 4.0 25 170 154 66 80 219 2.3 1-1/4" 8.40 7.84 2.75 4.13 10.59 7.5 32 214 199 70 105 269 3.4 1-1/2" 9.56 7.84 2.75 4.13 10.59 8.5 40 243 199 70 105 269 3.9 2" 11.38 6.77 3.86 4.83 10.63 15.1 50 289 172 98 123 270 6.85 2-1/2" 12.20 6.77 3.86 4.38 10.63 17.8 65 310 172 98 123 270 8.07 Gauge Connections D ► 3/4"through 1-1/2" hasA A 1/8" FNPT LIE B • © Y • i .- . c! i II . IN" ■ ice`: moi� '�1��� _� �\Ili° 11 0 , i ill A inn V When Ordering, Please Specify 1.Catalog No. CRD-L 2. Size 3. Adjustment Range 4. Optional Lock ingCap ® CLA-VAL Represented By: VIVII. 1701 Pl .Costa Ma, CA Phone:acentia 949-722Ave-4800•Faxes:949-548-5441 92627-4475 LIN, CLA-VAL CANADA CLA-VAL EUROPE 4687 Christie Drive Chemin des Mesanges 1 Beamsville,Ontario CH-1032 Romanel/ LauC LA VALM Canada L09%75463-4963 Phose: 4 21-643-15 Phone: Phone: 41 21 643 15 55 Fax: 905-563-4040 Fax: 41-21-643-15-50 E-CR D-L(R-11/2015) @COPYRIGHT CLA-VAL 2015 Printed in USA Specifications subject to change without notice. www.cla-val.com ES-A-LF2000B Series LF2000B AMES Double Check Valve Assemblies FIREWATERWORKS Sizes: 1h — 2" (15 —60mm) LEAD FREE Features • Ease of maintenance with only one cover • Top entry r • Replaceable seats and seat discs • • Modular construction 410 • Compact design 3/a" LF2000B • 1/2" -2" (15-50mm)Lead Free" (20mm) cast silicon copper alloy body construction Series LF2000B DoubleCheck Valve Assemblies shall be installed at referenced cross- • Top mounted ball valve test cocks connections to prevent the backflow of polluted water into the potable water supply.Only • Low pressure drop those cross-comections identified by local inspection authorities as non-health hazard • No special tools required shall be allowed the use of an approved double check valve assembly. • 1/2" -1" (15-25 mm) have Check with local authority having jurisdiction regarding vertical orientation,frequency of tee handles testing or other installation requirements. These valves meet the requirements of ASSE Std. 1015 and AWWA Std.C510 and are approved by the Foundation for Cross-Comection Controland Hydraulic Research at the Available Models University of Southern California.The LF2000B features Lead Free"construction to com- ply with Lead Free"installation requirements. Suffix: B- Quarterturn ball valves Specifications LBV- less ball valves A DoubleCheck Valve Assembly shall be installed at each noted location.The Double Check Valve Assemblies shall be constructed using Lead Free"materials. Lead Free" valves shall comp lywith state codes and standards,where applicable, requiring reduced Pressure — Tem erature lead content.The assembly shall consist of two positive seating check modules with l� captured springs and rubber seat discs.The check module seats and seat discs shall be Temperature Range:33°F-140°F replaceable.Service of all internal components shall be through a single access cover (0.5°C-60°C) secured with stainless steel bolts.The assembly shall also include two resilient seated iso- Maximum Working Pressure: 175psi lation valves and four top mounted, resilient seated test cocks.The assembly shall meet (12.06 bar) the requirements of ASSE Std. 1015 and AWWAStd.C510. Approved by the Foundation for Cross-Comection Control and Hydraulic Research at the University of Southern Cali- fomia.Assembly shall be an Ames Company Series LF2000B. Standards Approvals AWWAStd. C510, IAP MO PS31 OSSIFj c�p4o "The wetted surface of this product u p C ® US c us contacted by consumable water 1015 B64.5 3/4"-2" contains less than 0.25%of lead by (LBV Models Only) weight. Approved bythe Foundation for Cross-Connection Control and Hydratlic Research at the University of Southern California. LBV models not listed. Horizontal and vertical"flow up"approval on all sizes. Job Name Contractor Job Location Approval Engineer Contractor's P.O.No. Approval Representative Ames product specifications in U.S.customary units and metric are appro timate and are provided for reference only.For precise measurements,please contact Ames Technical Service.Ames reserves the right to change or modify prodict design,construction,spedfications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfi rewater.com Dimensions - Weights Nikk A 1� ....... - mm 1.--.11.. 0,11 ® -� 0 ��•I1�11"-)� F H` I ---- LF20008 G SIZE(DN) DIMENSIONS WEIGHT A B C F G H I in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 12 15 10 254 4% 117 27A6 62 5 127 3% 85 2516 59 2'/6 52 4.5 2 3/4 20 111/2 282 4 102 3'/e 79 63/6 157 37/6 87 21/s 54 15/6 33 _ 5 2.3 1 25 131/4 337 5% 130 4 102 712 191 3% 85 11 Y1s 43 111/6 43 12 5.4 11/4 32 16% 416 5 127 35/16 84 91/ 241 5 127 3 76 2 50 15 6.8 112 40 163/4 425 4% 124 312 89 93/4 248 513/6 148 31/s 79 211/6 68 15.86 7.2 2 50 191/2 495 614 159 4 102 13% 340 6%6 156 37/s 87 211/6 68 25.75 11.7 Strainer sold separately Capacities kPa psi A 11/4"(32mm) As comp iledfrom documented Foundation for Cross-Connection Control 96 14 and Hydraulic Research at the Universityof Southern California lab tests. 0 83 12 to *Typical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) 0 69 10 55 8 kPa psi 1/2"(1517 m) _ 41 6 N 83 12 y 28 4 O 69 10 E 14 2 °°°'- -i 55 80. 0 0 • 41 6 y 28 4 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm co U) 14 2 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 0. 0 0 5 7.5 10 15 fps 0 2 4 6 8 10 12 gpm 1.5 2.3 3.0 4.6 mps AP 0 7.6 15.2 22.8 30.4 38 45.61pm Flow Rate 5 7.5 10 fps 1.5 2.3 3.0 mps kPa psi 11/2"(40mm) Flow Rate 83 12 kPa psiA 3/4"(20mm) u) 69 10 0152 22 0 55 8 co 41 6 J 124 18 2 28 4 i 96 14 y 14 2 w 69 10 d 0 0 y Il Apo 10 20 30 40 50 60 70 80 90 100 110 120 gpm a 41 6 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 14 2 �� 5 7.5 10 15 fps 0 5 10 15 20 25 30 35 40 45 50 gpm 1.5 2.3 3.0 4.6 mps AP 0 19 38 57 76 95 114 133 152 171 190 Ipm Flow Rate 7.5 15 fps 2.3 4.6 mps kPa psi 0 2" Flow Rate 1n 83 12 kPa psi "(25mm) cn N 110 16 w J 69 10 A 1 55 8 J 83 12 3 8 41 6 • 69 10 3 55 8 y 28 4 N 41 6 214 2 LD 28 4 { 0 0 0- 14 2 - 0 25 50 75 100 125 150 175 200 gpm AP 0 95 190 285 380 475 570 665 760 Ipm 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm 5 7.5 10 15 fps AP 0 19 38 57 76 95 114 133 152 171 190 209 2281pm 1.5 2.3 3.0 4.6 mps 5 7.5 10 15 fps Flow Rate 1.5 2.3 3.0 4.6 mps Flow Rate �a C OUILO%,� �� c A M E S9001-2008 FIRE a WATERWORKS' www.amesfirewater.com ,MeMet�^ CERTIFIED A Watts Water Technologies Company USA: Backflow- Tel:(916)928-0123 •Fax:(916)928-9333 Control Valves- Tel:(713)943-0688•Fax:(713)944-9445 Canada: Tel:(905)332-4090•Fax:(905)332-7068 ES-A-LF2000B 1322 ©2013 Ames Fire&Waterworks FOR SMALL PIPE VSR-SF PPOTfFR VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL,ULC,CSFM Listedand NYMEAAccepted,CE Marked Service Pressure: Up to250 PSI (17,2 BAR) Minimum Flow Rate for Alarm: 8-10 GPM(30-38 Lpm) Maximum Surge: 18 FPS(10 m/s) Enclosure:Die-cast, red enamel finish Cover held in place wit h t amper resist antscrews Contact Ratings: Two setsof SPDT(Form C) 15.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. ° Usage: Listed plastic,copper and schedule 40 iron pipe. Fits pipe sizes - 1" (25mm), 1 1/4" (32mm), 1 1/2" (38mm) and 2" (50mm) Note:12 paddles are furnished with each unit,one for each pipe size of threaded and sweat TEE,one for 1" (25mm)CPVC,one for 1" (25mm) CPVC(Central), one for 1 1/2" (38mm) polybutylene and one for 1 1/2" (38mm) threaded (Japan). (CTS-Coppert ubing size) Environmental Specifications: • Suitable for indoor or out door use withfactory installed gasket and die-cast housing. • NEMA 4/IP55 rat edenclosure-use wit happropriate conduit fit ing. • Temperature range:40° F to 120° F,4,5° C to 49° C) Caution: This device is not int ended for applicat ions in explosive environments. Service Use: StockNo.1113000 Automat icSprinkler NFPA-13 U.S. Pat.No. 3921989, Canadian Pat.No. 1009680 One or t wofamily dwelling NFPA 13D Residential occupancy up tofourstories NFPA-13R Ot herPatents Pending National Fire Alarm Code NFPA-72 Optional:Cover Tamper Switch Kit,Stock No. 0090018 The Model VSR-SF is a vane t ypewat erflowswit chforuse on wet wat erf low. sprinkler systems that use 1" (25mm), 1 1/4" (32mm), 1 1/2" The vane must not rub the inside of the TEE or bind in any way. (38mm) or 2" (50mm) pipe size. The unit may also be used as The stem should move freely when operated by hand. a sectional waterflow detect or on large systems. The device can also be used in copper or plastic pipe installa- The unit contains two single pole double throw snap act ion t ions wit h t he proper adapters so t hat the specified TEE fit t ing switches and an adjustable, instantly recycling pneumatic re- may be installed on the pipe run. tard.The switchesare act uat edwhen a flow of 8-10 gallons per minute(30-38 Lpm)or more occurs downst ream of the device. INSPECTION AND TESTING: Checktheoperationoftheunitby The flow condit ion must exist for a period of time necessary to opening the inspector'stestvalve at theend of thesprinklerline overcome the selected ret ard period. or t hedrain and t estconnect ion,if an inspect or'st estvalve is not provided. INSTALLATION: These devices may be mounted in horizontal or verticalpipe. On horizontal pipe they should be installed on If there are no provisions for t est ing t he operat ion of the flow t het opside of the pipe where t heywill be accessible. The units detect iondevice on t hesyst em,applicat ionof t heVSR SF is not should not be installed wit hin 6"(15cm)of a valve,drain or fit ing recommended or advisable which changes the direct ion of t he waterflow. The unit has a 1" The frequency of the inspect ion and t est ing and its associated NPT bushing for threading into a non-corrosive TEE. See Fig. protective monitoring system should be in accordance with the 2 for proper TEE size, type and installation. applicable NFPA Codes and Standards and/or aut horit yhaving Screw t he device int o t he TEE fit ingas shown in Fig. 2. Care jurisdict ion (manufacturer recommends quarterly or more fre- must be taken t o properly orient the device for the direct ion of quent ly). Pot teiElectricSignal Company•2081 Craig Road,St.Louis,MO,63146-4161 •Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8800003-REVX PAGE 1 OF2 MFG.#5400802-12/01 VSR-SF POTTER. VANE TYPE WATERFLOW 8 FOR SMALL PIPE The Symbol of Protection ALARM SWITCH WITH RETARD FIG. 1 DO NOT LEAVE COVER FIG. 2 OFF FOR EXTENDED Retard Adjustment: PERIOD OF TIME g,,,•"° To change time, turn knob Fel - (eit her direct ion) for desired L FLOW time dela Use the minimum .. �+�se 1 11 16"/ APPROX. y• tilVp.p. ly. �� � � (4,3mm) amount of ret ardnecessary t o MOUNT SO I I- (WHITE) COM, � ' I prevent false alarms. A "B" ARROW ON (RED) N.O.BUSHING j (BLACK) N.C. settingis usually adequate for POINTS IN 1 DIRECTION OF t his. Factory set at"B". WATERFLOW 1�11. 1"NPT I �' \\\\@ THREADED DEPTH FITTING ON DIRECTION OF 51 ALL SIZES WATER FLOW RUN OF THE ^ TEE MAYBE /\\�1 THREADED OR 4� ii# SWEAT TYPE DIRECTION OF Screwthedevice intotheteefittingas shown.Care must be takento WATERFLOW Vproperly orient the device for the direct ion of waterflow.On sweat tees,no DWG. #737-31 threaded bushings,inserts,or adapt ersare permit t ed,unless they comply DWG. #802-30 wit ht he dimensions list ed in the chart below. Important: Imp ortant-The depth tot he inside bott omof the tee should have the There are 12 paddles fur- TOUPREVENT LEAKAGE APPLY TEFLON TAPE SEALANT following dimensions: nished witheach unit.One for TO MALE THREADS ONLY, DO NOT USE ANY OTHER each size of t hreaded,sweat or TYPE OF LUBRICANT OR SEALANT, APPROXIMATE DEPTH REQUIREMENT plastic TEE as described in TEE SIZE THREADED SWEAT CTS, POLYBUTYLENE CPVC Fig. 2. These paddles have APPROX. RETARD SETTINGS (IN SEC.) raised let t eringt hat shows t he o A B c D E 1" x 1" x 1" 2 1/16" 1 3/4" N/A 2 7/16" size and t 0 10-25 20-40 35-55 50-70 60-90 1 1/4" x 1 1/4" x 1" 2 7/16" 2 7/16" N/A N/A pipe ypeof TEE that I 1/2" x 1 1/2" x 1" 2 11/16" 2 1/4" 2 1/2" N/A t hey are t o be used with.The 2" x 2" x1" 3 3/16" 2 3/4" N/A N/A proper paddle must be used. DWG. #735-33 The paddle must be properly attached (see drawing) and the screw t hat holds the pad- dle must be securely tight- ened. SWITCHTERMINALCONNECTIONSCLAMPINGPLATETERMINAL FIG.3 ��r I0Go�'I"G CAUTION: ,O�/ An uninsulated section of a single conduct or should not be looped around t he terminal and serve as twoseparateconnections. The wire must be �� severed,t herebyproviding supervision of the connect ion in the event t hat 0 OII DWG.#923-3 the wire becomes dislodged from under the terminal. FIG.4 TYPICALELECTRICALCONNECTIONS FIG. 5 NOTES: To remove knockouts: Place BELL TRANSFORMER cuss B STYLE B> 1. The model VSR-SF has two screwdriver at edge of knock- LOCALOR BATTERY POWERED END-OF-LINE RESISTOR CKT-(SEE NOTE) swit ches,one can be used t o outs,not in the center. COM COM. OPEN ON ALARM OPEN ON CLOSE ON operate a central station, CLOSE ON ALARM ALARM ALARM EOL rO rieta or remotesi nal- N,O. 19 RESISTOR ing proprietary 9 �N,C. N.O. �N,C, iunit, while the other is SIGNALING DEVICE SUPERVISED LOOP(SEE NOTE) used to operate local au- COM, dible or visual annunciator. I / TYPICAL SWITCH ACTION OPEN ON CLOSE ON TO ADA1 COEL FROM ALARM ALARM DEVICES 2. For supervised circuits see A OPEN ON, CLOSE ON CONTROL OR RETURN "Switch Terminal Connec- � ALARM ALARM PANEL N.O. �RC, TO CONTROL N.O. `N,C. tions" drawing and caution ;� DWG. #761-15 note(Fig.3). rl 4111 , o 4- II M APPLICATION WARNING! Due to the possibilityof unintended discharges caused by pressure surges,t rappedair,or short ret ardt imes,waterflow switches t hat are monit oringwet pipe sprinkler syst ems should not be used as the sole init iat ingdevice t o discharge AF FF,deluge, or chemical suppression syst ems. PRINTED IN USA MKT.#8800003-REVX PAGE 2 OF 2 MFG.#5400802-12/01 RBVS POTTER UNIVERSAL BALL The Symbol of Protection VALVE SWITCH UL and cUL Listed,FM,CSFM App roved Dimensions: (in cludin gmoun tin g clamps) uo:I:It Large Clamps: 6"L x 5"W x 5.2"H 15,2 cm L x 12,7 cm W x 13,2 cm H •T. 1°1' s 4 Small Clamps: 6"L x 4"W x 5.2"H 15,2 cm L x 10,2 cm W x 13,2 cm H • Weight: With Large Clamps: 13.6 oz.(386,9 g.) With Small Clamps: 11.0 oz.(311,2 g.) e I Enclosure: Non-Corrosive Composite Material Environmental Limitations: • NEMA 4 rated en closure when proper electrical fittings are used.(1P67) • Temperature ran ge:-40°F to 150°F(-40°C to 65°C) • Not for use in hazardous locations Housing Cover Tamper: Activated by housingcover removal US Paten tNo.6,945,509 (Stock No. 1000035 only) Contact Ratings: SPDT Contacts: 10A at 125/250 VAC RBVS Stock No. 1000040(w/o Cover Tamper) 2A at 30 VDC RBVS-T Stock No. 1000035(w/Cover Tamper) SPDT Cover Tamper: 3A at 250 VAC General Installation On Lever Handle(See Fig.2) The Model RBVS is designed to mon itoithe fully open position of a ball valve 1. Select clamps an dclampin gbolts based upon pipe/valve size,see Table 1. in stalledin a sprin klersystem.The un itwill fit on most ball valves in stalledon 2. In sertrubber clamp grippers in to clamps,see Fig.2. back-fl ow-preventers an dalarm trim lin esof dry,alarm,and deluge sprinkler 3. Place one clamp on top of pipe/ball valve n ear the valve han dle an d valves.The switch operates if the ball valve han dleis moved from the open in sertclampin gbolts through it. position.However,the switch does n ottrack the position of the handle or ball. 4. Place other clamp over clampin gbolts from ben eaththe in stallation an d When the ball valve han dleis in the open position,a spring-loaded switch button thread hex n utson to the clampin gbolts,but do n ot fully tighten,(be sure will con tactthe valve handle.When the han dleis moved from the open position, hex nuts seat properly in clamp hex recesses).(NOTE:Some installation s this switch button exten ds to the tripped position,an d the RBVS con tactschan ge may require one of the moun tin gbolts to be in sertedfrom the bottom of state,thereby openingor closing a circuit.A cover tamper switch is available and the brackets andthen trimmed to allow the extension bracket to clear. is activated by the removal of the RBVS housin gcover.If an attempt is made See Fig.4) to remove the RBVS by the removal of the moun tin gbrackets,the un itwill be 5. Attach extension bracket(if necessary to use for positioning)to top clamp set in tothe tripped mode by this action. using'/4-20 X'/4"Hex bolt an dwasher,but don otfully tighten. The RBVS can be moun ted to the hex portion of the ball valve or back-flow- 6. Attach"L"bracket(RBVS switch en closure is loosely attached to"L" preven teror to the adjoin in gpipe via two clamps.The RBVS is shipped with two bracket)to exten sion bracket usin g'/4-20 X 3/4"Hex bolt an dwasher,but sets of moun tin gclamps to accommodate various pipe andvalve sizes,refer to do surebly tighten. Table 1.An"L"shaped andoffset bracket for moun tin gthe switch enclosure and 7. Be sure ball valve is in the fully open position. an exten sionbracket add to the moun tin gflexibility of the RBVS.See"Typical 8. Slide loosely assembled RBVS switch en closura position that permits the switch button to con tactthe valve han dle approximately 1" from its Moun tin gDiagram"an d"In stallatiomn dOperation"on followin gpage. in sideen d.See Fig. 1 for approximate location.Cut an dremove the plastic Testing coating from the ball valve han dleto allow the RBVS switch button to The RBVS and its associated protective monitoring system should be tested contact(an dbe activated by)the metal of the handle. in accordan cewith applicable NFPA codes and standards an d/orthe authority 9. Tighten clampin gscrews alternately to an eventual30 in-lbs.(minimum) havin gjurisdiction(manufacturer recommen dsquarterly or more frequently). of torque. 10. Main tainposition of switch en closure over valve han dle an d secure bolt Fig.! Internal Components that holds the exten sion bracket to the clamping assembly.It may be NORMALLY OPEN necessary to close valve to access this bolt. 11. Position"L"bracket so that it con tactsthe back edge of the valve han dle,an d NORMALLY CLOSED �, secure its bolt.It may benecessarytoclose valve toaccess this bolt. COMMON �� ' �.� 12. With the actuator fullyretracted,position RBVS switch enclosure to k �` ;r= ` con tact the valve handle squarely,see Fig. 1. ""� �' 13. With RBVS switch en closure held squarely in contactwith valve handle, STRAIN RELIEF q Y 11111,50404 � � ® SWITCH BUTTON securely tighten the two tamper resistant screws on the backside of the IIrBLACKCOVER RED - N.O. `• ••• ,L' '�`I0 LOCATION TAMPER GRED — N.C, • �✓ ON HANDLE en closure. WHITE - COMM 14. Close andopen the valve to verify operation.The actuator should easily retract when the valve han dle is in the open position. 15. Fully open the valve. MOUNT SO 16. Remove the cover andwire main switch andtam tamper switch if applicable. SWITCH BUTTON \�� p pp IS APPROX. 1" FROM PLASTIC COATINGO REMOVED FROM Carefully route tamper switch wires through strain relief channefin switch HANDLE INSIDE END BALL VALVE HANDLE en closure Fully seat the wires in tothe bottom of the chann el See Fig.1. CONTACTIN CTH BUTTON 17. Replace RBVS switch en closure over an dsecurel tightencover screw. DWG #1086-1 AREA P Y g Potter Electric Sign alCompany,LLC•2081 Craig Road,St.Louis,MO,63146-4161 •Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5401086-REV U PAGE 1 OF 2 5/08 P POTTER RBVS UNIVERSAL BALL ® The Symbol of Protection VALVE SWITCH Fig.2 Typical Mounting Diagram Table 1 Clamp Sizing 1: LENGTH Pipe Valve/Size Clamp Clamping Bolts SWITCH 1/2"to 3/4"(12,5 to 19mm) Small 10-32 x 2 1/2 --11 ENCLOSURE .. O 1"to 2"(25 to 50mm) Large 1/4-20 x 4" NIil "L" BRACKET it HEIGHT Switch Terminal Connections,Clamping Plate Terminal -=fir EXT, BRACKET 05 2"�a� '�'7 pig 7.7. ` (IF NECESSARY) — ' �'o -� �'� A CAUTION O BCLAMPS � )0( unin otbtelooped of aroun gthcon terminal shouldnotbeloo edaroundtheterminal g Ii /14-010 ■ oandserveastwose erateconnections,The pi 17CLAMPro�too�' DWOO 923-3 wire must be severed,thereby providing GRIPPERS supervision of the con n ectionin the even t WIDTH 4" (SMALL) f that the wire becomes dislodged from DWG #1086-2 5" (LARGE) undertheterminal. Typical Electrical Connections LOCAL CIRCUIT TRANSFORMER OR BATTERY POWER STYLE D (CLASS A) SUPERVISED LOOP STYLE B (CLASS B) SUPERVISED CIRCUIT N.C. SIGNALING COM, COM, TO N,C, N,O, DEVICE NA NN,C, UNIT,O. N.O. CONTROL COM, NO END-OF-LINE RESISTOR DWG. #1086-4 Tamper Switch Connections Fig.3 COVER TAMPER & RBVS CONNECTED COVER TAMPER & RBVS WIRED SWITCH ENCLOSURE TO THE SAME ZONE ON THE FACP TO SEPERATE ZONES COVER ` CM N,O,COM. D- TAMPER OFFSET BRACKET COM, N.O. COM. • / --°."'J FACP COVER EOLR N.C, OL TAMPER FACP ER FAC EOLR I ' , N.O. S �y ll' i-6,® I ,I DWG.51086-5 NIS, I- + Installation on Tee Handle(See Fig.3) ��� �' %� �`� � 'L"BRACKET . 1. Select clamps and clamping bolts based upon pipe/valve size,see Table 1. � f G� -� 2. Insert rubber clamp grippers into clamps,See Fig.3. 401,,...�./ V i„ 3. Place one clamp on top of pipe/ball valve near the valve handle and "MPS � 1. insert clamping bolts through it. L - 4. Place other clamp over clamping bolts f rombeneath the installation CLAMP GRIPPERS DWG X1086-3 and thread hex nuts onto the clamping bolts,but do not fully tighten, (be sure hex nuts seat properly in clamp hex recesses). 5. Loosely attach "L" bracket to the "offset" bracket and "off set" bracket to the RBVS housing. Fig.4 6. Be sure ball valve is in the fully open position. (; ---------,- it7. Slide loosely assembled RBVS switch enclosure to a position that RBVS ®� permits the switch button to contact the valve handle approximately 11 l 1/2"from the end of the handle.Cut and remove the plastic coating 11 I J I f ronthe ball valve handle to allow the RBVS switch button to contact (and be activated by)the metal of the handle. O 8. Tighten clamping screws alternately and I/4-20 X 3/4"bolt to 30 in-lbs. (minimum)of torque. SOME INSTALLATIONS MAY �■�■� 9. With the valve handle fully open, slide the RBVS housing down CAUSE INTERFERENCE _ ��■ BETWEENMOUNTINO BOLTAND �_ _ until the switch operatesplus 1/8 inch.Tighten the screws holding1 p g OFFSET BRACKET.INSTALL BOLT A1 the RBVS to the"offset"bracket. FROM BOTTOM ANDTRIMAS��■ini ■ PIPE 10.Remove the RBVS switch enclosure cover. NEEDED TO CORRECT.11. Close and open the valve to verif yoperation.The actuator should easily retract up when the valve handle is in the open position. 12.Fully open the valve. \/ 13.Wire main switch and tamper switch(if applicable).Carefully route Irl tamper switch wires through strain reliefchannel in switch enclosure. Fully seat the wires into the bottom of the channel. See Fig. 1. Dwca 108 6-6 14. Replace RBVS switch enclosure cover and securely tighten cover screw. PRINTED IN USA MFG.#5401086-REV U PAGE 2 OF 2 5/08 AP c ® us _AN -rigio-a 1E)-L'-n 3 APP® Model 1011A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve Factory Rated at 175 PSI with other settings available DIMENSIONS MODEL 1O11A - FRONT VIEW Orifice Size Available:3/8", 7/is", 1/2", 17/32", ELO(5/8")", ESFR(3/a")*,&K25"" A SIZE A I B C D E F G H —E 1 INLET iFieMiriNi 3/411 79/16" 11/2" 23/16" 35/8" 33/8" 113/16" 49/16" 63/8" TO i F —O II(191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) DRAIN H Ili it. . 1 i imi ,i 0 1" 79/16" 11/2" 23/16" 35/8" 33/8" 113/16" 49/16" 63/8" G •� O �, (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) `' ,z•z5 _z_,11611 11/4' 715/16" 111/16" 29/16" 41/4" 35/8" 115/16" 59/16" 51/2 (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 815/16" 113/16" 31/4" 51/16" 37/8" 25/8" 81/4" 107/8" MODEL 1O11A - PLAN VIEW 11/2" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 815/16" 113/16" 31/4" 51/16" 37/8" 25/8" 81/4" 107/8" 4 A ► 2 (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) *Available on 11/4" to 2" size units only ""Available on 11/2" and 2" size units only1 J 1 1 DRAIN�I i 111= ll I MM. THE MODEL 1O11A PROVIDES ALL OF THE FOLLOWING... IM t :_. off/. From the 2007 Edition of NFPA13 Chapter 8.16.2.4.1" Provisions shall be made to properly drain all parts of the system. T Chapter 8.16.2.4.2 Drain connections,interiorsectio nal or floor controlvalve(s)— &8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. MATERIALS Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling Handle:Steel the flow of the drain. Stem:Rod Brass Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into Ball:C.P. Brass a drain capable of acceptingfull flow...using an approved sight Body:Bronze test connection containing a smooth bore corrosion-resistant Valve Seat:Impregnated TeflorP orifice giving a flow equivalent to one sprinkler... Indicator Plate:Steel Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Relief Valve:Bro nze Chapter 8.17.4.2.4 shall be permitted to be installed in any location... downstream Bypass Fittings:Brass of the waterflow alarm. Bypass Tubing: Nylobraid Chapter 8.17.4.3.1 (Dry Pip eSystem)a trip test connection not less than 1" in diameter,terminating in a smooth bore corrosion-resistant orifice, APPROVALS to provide a flow equivalent to one sprinkler... UL and ULC Listed:(EX4019 Chapter 8.17.4.3.2 The trip test connection...with a shutoff valve and plug not less &EX4 533) than 1", at least one of which shall be brass. FM Approved Chapter 7.1.2 -a gridded wet pipe system shall be provided with a relief valve NYC-BSA No.720-87-SM set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than 1/2" in size shall be provided on the «+:** �, * 4, �1 discharge side of the pressure-reducing valve set to operate at a *�**�«* pressure not exceeding 175 PSI. �, Chapter A.8.16.1.2.3 -consideration should be given to piping the discharge fro mthe x��1� (pressure relief)valve MADE IN U.S.A. USA Patent # 4741361 and Other Patents Pending AGF Manufacturing Inc. Job Name: AG100 Quaker Lane,Malvern,PA 19355 Phone:610-240-4900 FFax:610-240-4906 Architect:Engineer: www.testandrain.com Contractor: