Loading...
HomeMy WebLinkAboutF18-0024_approved documents_1528733404.pdf 75 South Frontage Road Fire-Construction Permit 0West, TOWN OF VAIL F18-0024 TOWN Vail,CO 81657 Issued: 06/11/2018 TOWN Or VAIL Office:970.479.2139 Inspection Line:970.479.2149 Property Information Address: 4872 MEADOW LN A(210113104015 A)(210113104015) Unit#:A Parcel Number: 210113104015 LegalDescription: Subdivision:BIGHORN 5TH ADDITION Block:7 Lot:14 PARCELA BK-0461 PG-0088 QCD 04-14-87 BK-0461 PG-0551 QCD 04-22-87 Contacts Contact Type:Applicant Full Name:Ronald Lumsden Address: 11901 E 14th Ave Aurora,CO 80010 Phone: 3033664905 Contact Type:Property Owner Full Name:4872 MEADOW LANE LLC Address: Phone: None Contractor Contractor Type:Fire Protection Company: Arapahoe Fire Protection, Inc State License#: 18-S-00034 Phone: 3033664905 Projectlnformation Project Name:Kuelling Residence2017 Project Description: Unit A Arapahoe Fire will install a wet fire sprinkler system in thethree level 13D residence. Fees Paid Account#:001-0000.31111.00-Fire Suppression Permit Fee Fee Amount: $1,774.04 Account#:001-0000.21123.00 Fire Suppression Review Fee Fee Amount: $432.00 Total Paid: $2,206.04 Conditions Issued By:Town of Vail Fireand Emergency Services Department NOTICE:By issuance of this Permitthe applicant agrees to complyto all Titles of the Town of Vail Code and all applicable State and Federal law.Failure to do so will void this Permit and the applicant shallforfeit all applicablefees. MATERIAL DATA HYDRAULIC CALCULATIONS z A! •Fiz?.CalloraTIONINC 11901 East 14th Avenue Aurora, Colorado 80010 Phone: (303) 366-4905 Fax:(303) 366-4966 FOR PRIMARY RESIDENCE 4872 Meadow Lane Vail, CO JOB 8178 Ron Lumsden } Hydraulic Summary Job Number:8179-REMO TEAREA 1 s• - Re•ort Descri.tion:Residential 1 Job Job Number Design Engineer 8179 RONLUMSDEN Job Name: Slate Certification/License Number 4872 MEADOWLANE Address 1 AHJ VAIL,CO 81657 Address 2 Job Site/Building PRIMARY RESIDENCE Address 3 Drawing Name 8178 Primary Residence-Upper Level.cad System RemoteArea(s) Most Demanding Sprinkler Data Occupancy On Siff:c 4.9 K-Factor 16.97 at 12.000 Residential REMOTEAREA 1 Hose Allowance At Source Density Area of Application 0.00 0.10gpm/ft2 900.00ft2(Actual 263.51ft2) Additional Hose Supplies Number O(Sprinklers Calculated Coverage Per Sprinkler Node Flow(opm) 2 100.00ft2 AutoPeak Results:Pressure For Remote Area(s)Adjacent To Most Remote Area Prepared Linder Supervision Of: Ronald Lumsden NICET Level :V Registration # 118272 Total Hose Streams 0.00 System Flow Demand Total Water Required(Including Hose Allowance) 34.37 34.37 Maximum Pressure Unbalance In Loops 0.000 �fr Maximum Velocity Above Ground Signature:_ _ Jam, 12u61 between nodes 76 and 5 Maximum velocity Under Ground Volume capacity of Wet Pipes Volume capacity of Dry Pipes 50.69ga1 Supplies —•• Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node Name (gpm) (psi) (psi) @ (gpm) (psi) @ (gpm) (psi) (psi) 1 Water Supply 90.000 16.720 759.30 89.761 34.37 59.568 30.193 Contractors Contractor Number Contact Name Contact Title 21 Ron Lumsden PM Name of Contractor: Phone Extension Arapahoe Fire Protection 303-366-4905 210 Address 1 FAX 11901 E.14th Ave Address 2 E-mail Aurora,CO 80010 ron@arapahoefire.com Address 3 Web-Site ©M.E.P.CAD,Inc. AutoSPRINK®12 v12.1.1.0 5/23/2018 9:14:34AM Page 1 Hydraulic Graph Job Number:8179-REMO TEAREA 1 Report Description:Residential(1) Supply at Node 1 100 90 Static Pressure 90.000 80 70 60 4.37 @ 59.568 Ul Q J 50 N fA N a` 40—System demand curve 30 20 J 759.30 @ 16.720 10 — — 0 IOILI111111II 111111III 111111111 111 1 1 1 1 1 1 111111111 111111111 1 1 1 1 1 1 1 1 1 111111111 111111111 0150 300 450 600 750 900 1050 1200 1350 1500 Water flow,gpm Hydraulic Graph Supply at Node 1 Static:Pressure 90.000 Residual:Pressure 16.720 @ 759.30 Available Pressure at Time of Test 89.761 @ 34.37 system oemaea 59.568 @ 34.37 System Demand(Including Hose Allowance at Source) 59.568 @ 34.37 ,ik,©M.E.P.CAD,Inc. AutoSPRINK®12 v12.1.1.0 5/23/2018 9:14:36AM Page 2 i Summary Of Outflowing Devices 1 Job Number:8179-REMOTEAREA1 g:-...-%' - Report Description:Residential(1) Actual Flow Minimum Flow K-Factor Pressure Device (qpm) (qpm) (K) (psi) Ets Sprink ler 101 16.97 16.97 4.9 12.000 Sprinkler 102 17.39 16.97 4.9 12.597 * Most Demanding Sprinkler Data k,©M.E.P.CAD,Inc. In AutoSPRINK®12 v12.1.1.0 5/23/2018 9:14:38AM Page 3 I} Node Analysis Job Number:8179-REMO TEAREA 1 `• ' ' - Report Description:Residential(1) Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 1 -36-3 S 59.568 34.37 101 9-1% Spr(-12.000) 12.000 16.97 102 9-1% Spr(-12.597) 12.597 17.39 2 -10-3 E(2-0) 41.152 3 10-1% E(2-0) 11.855 4 10-1% E(2-0) 12.073 5 10-1% T(2-0) 12.693 6 10-1% E(2-0) 12.465 45 -16-6% 44.162 49 -15-5% cplg(1-0) 43.644 54 -10-3 E(2-0) 37.264 76 -0-10 E(2-0) 28.756 L©M.E.P.CAD,Inc. 15 AutoSPRINK®12 v12.1.1.0 5/23/2018 9:14:40AM Page 4 iliiiHydraulic Analysis Job Number:8179-REMOTE AREA 1 ® Report Description:Residential(1) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length OF Route 1 DR 1.049 16.97 6.30 120 0.096069 1-0 Pf 0.288 101 9-1% 16.97 4.9 12.000 Sprinkler, 2-0 Pe -0.434 3 10-1% 11.855 E(2-0) 3-0 Pv BL 0.995 16.97 7.00 150 0.082239 0-8 Pf 0.218 3 10-11% 11.855 2-0 Pe 4 10-11/2 12.073 E(2-0) 2-8 Pv BL 1.055 16.97 6.23 150 0.061835 10-0'% Pf 0.621 4 10-1% 12.073 Pe 5 10-1% 12.693 10-0'% Pv BL 1.055 34.37 12.61 150 0.228013 40-7% Pf 11.312 5 10-1% 17.39 12.693 FI ow(q)from Route 2 9-0 Pe 4.751 76 -0-10 28.756 EE(1-0),3E(2-0),T(2-0) 49-7% Pv BL 1.055 34.37 12.61 150 0.228013 13-5 Pf 4.425 76 -0-10 28.756 6-0 Pe 4.082 54 -10-3 37.264 2E(2-0),T(2-0) 19-5 Pv BL 1.055 34.37 12.61 150 0.228013 11-0% Pf 3.888 54 -10-3 37.264 6-0 Pe 2 -10-3 41.152 T(2-0),2E(2-0) 17-0% Pv BL 1.527 34.37 6.02 150 0.037662 5-2% Pf 0.234 2 -10-3 41.152 1-0 Pe 2.259 49 -15-5% 43.644 cplg(1-0) 6-2% Pv BL 1.610 34.37 5.42 120 0.043979 1-1 Pf 0.048 49 -15-5% 43.644 Pe 0.470 45 -16-6% 44.162 1-1 Pv BL 1.527 34.37 6.02 150 0.037662 161-3 Pf 6.863 45 -16-6% 44.162 21-0 Pe 8.543 1 -36-3 59.568 5E(2-6),BFP,EE(1-6),2T(3-6), 182-3 Pv GV,S 0.00 Hose Al I owance4t Source 1 34.37 Route 2 DR 1.049 17.39 6.46 120 0.100485 1-0 Pf 0.301 102 9-1% 17.39 4.9 12.597 Sprinkler, 2-0 Pe -0.434 6 10-1% 12.465 E(2-0) 3-0 Pv BL 0.995 17.39 7.18 150 0.086019 0-8 Pf 0.228 6 10-1% 12.465 2-0 Pe 5 10-1% 12.693 T(2-0) 2-8 Pv Equival ent Pipe Lengths of Val vesand Fittings(C=120 only) 1111 C Val ueMultipl ier / Actual Inside Diameter \4'87 Val ueOf C 100 130 140 150 l Schedule40 Steel Pipe Inside Diameter I =Factor MultiplyingFactor 0.713 1.16 1.33 1.51 ©M.E.P.CAD,Inc. NU AutoSPRINK®12 v12.1.1.0 5/23/2018 9:14:42AM Page 5 Hydraulic Analysis Job Number:8179-REMOTE AREA 1 Report Description:Residential(1) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length Pipe Type LegendLEM Units Legend ' 11111namm Fittings Legend ' AO Arm-Over Diameter Inch ALV AlarmValve BL Branch Line Elevation Foot AngV AngleValve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BaIV BalIValve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Fl ow Turn 90° FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Will iamsConstant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe Del V Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe E 90°Elbow Pe Pressure due to elevationdifference between indicated points UG Underground Pv Velocity pressureat a point in a pipe EE 45°EI bow Eel 11%°El bow Ee2 22W El bow Fl ow Device fd Fl ex Drop FDC Fire Department Connection fE 90°FireLock(TM)El bow fEE 45°FireLock(TM)El bow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn El bow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Rel iefVal ve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee FI owTurn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. AutoSPRINK®12 v12.1.1.0 5/23/2018 9:14:42AM Page 6 Submittal viea 9 Package ProPress° System ❑ Potable Water ❑ Low Pressure Steam O Hydronic Heating 0 Fire Protection ❑ Chilled Water ❑ Vacuum ❑ Compressed Air ❑ Corgon ❑ Nitrogen N2 ❑ Oxygen 02 (non medical) ❑ Argon ❑ System Data Sheet 2 ProPress Product Instructions ProPress fort" to 2" copper tubing 3 ProPress XL for 21/4" to 4" copper tubing 4 ProPress° Dimensional Documentation ProPress fort" to 2" copper tubing 5 ProPress XL for 21/4" to 4" copper tubing 17 V iega Limited Warranty ProPress° Fittings And Valves 23 Viega LLC,12303 Airport Way,Ste.395• Broomfield,CO 80021• Ph:800-976-9819• Fax:800-976-9817 SM-PP 1017 1 of 23 Submittal viega 9 Package System Data Sheet ProPress®and ProPress XL(Copper)are safe,reliable and economical copper pipe installation systems that use modern cold press connection technology. Viega®ProPress fittings are for use with type K,L and M hard copper tubing from'/" to 4" and soft copper tubing in 1/2"to 11/a" _ diameters.All tubing must comply with the ASTM B88 standard. ProPress fittings are approved for installations in both above and �` ~ below ground applications.Per code,local inspector approval must be obtained prior to installation below ground. _" • mfr - , � ProPress has been used in Europe since the late 1980s and ` � _` in the United States since the late 1990s fora variety of �''_ • '�•, applications.Backed by two plumbing leaders with over 175 years of combined excellence. Listings and Certificates • NSF 61G • IAPMO PS117 • UL 213 • FM Class 1920 • ICC LC 1002 Approved Applications: • CSA MSE-13 • Potable Water • ABS • Hydronic Heating (w/Glycol) • Chilled Water International Listings and Certificates • Compressed Air • Deutsch Verein des Gas-und Wasserfachese.V. • Non-medical Gases (DVGW) • Fire Sprinkler(175 PSI maximum) • Lloyd's Register(LR) • Low Pressure Steam(15 PSI maximum) • Det Norske Veritas (DNV) • Vacuum(29.2 in. Hg maximum @ 68°F) • Registro Italiano Navale(RINA) In ProPress 1/2" to 4" dimensions,the Smart Connect Feature • Bureau Veritas (BV) assures leakage of liquids and/or gases from inside the system • KIWA past the sealing element of an unpressed connection.The function of this feature is to provide the installer quick and easy Compliant with: identification of connections which have not been pressed prior • ICC International Plumbing Code to putting the system into operation. • IAPMO Uniform Plumbing Code • PHCC National Standard Plumbing Code Recommended Tools: • • Florida Building Code,Volume ll Plumbing Code RIDGID RP 200-B (1/2"to 11/4") • NFPA13, 13D and 13R • RIDGID RP 210-B (1/2"to 11/4") • ASME B16.51 • RIDGID RP 320-E • U.S. Coast Guard • RIDGID RP 330-B or 330-C Viega ProPress fittings are offered in configurations including: • RIDGID RP 340 Elbows,Couplings,Reducers,Tees,Reducing Tees,Threaded • RIDGID CT 400 Adapters, Unions,Caps and Flanges.All threaded 1/2"to 2" Contact your local Viega representative for details on local fittings are Zero Lead bronze. approvals. Operating Parameters Operating Pressure: 200 PSI maximum Test Pressure: 600 PSI maximum Operating Temperature: 0°F to 250°F Viega LLC,12303 Airport Way,Ste.395• Broomfield,CO 80021• Ph:800-976-9819• Fax:800-976-9817 SM-PP 1017 2 of 23 Submittal viega 9 Package ProPress Product Instructions Viega ProPress® For Types K, L and M Hard Copper Tubing in 1/2" to 2" and Soft Copper Tubing in 1/2" to 11/4" A WARNING Read and understand all instructions r✓ for installing Viega ProPress fittings.Failure to follow all a instructions may result in extensive property damage, D serious injury or death. /J'�h111 f/ 1. Cut copper tubing at right angles using displacement- /� 1 2 3 type cutter or fine-toothed steel saw. 2.Remove burr from inside and outside of tub ing to prevent cutting sealing element. 3.Check seal for correct fit. Do not use oils or lubricants. op -Zji ��#`p Use only Viega ProPress Shiny Black EPDM or Dull _ a,., Black FKM sealing elements. f �,� �� . Note:For applications requiring Viega ProPress with FKM L . , ``r `\ sealing elements, remove the factory-installed EPDM 4 tis. 5 ( � 6 sealing element and replace with FKM sealing element. 4. Mark proper insertion depth as indicated by the Viega Pro Press Insertion Depth Chart. Improper insertion ,� depth may result in improper seal. rr ��� �9,7111,'� ��� 5.While turning slightly, slide press fitting onto tubing to ' i ,'i "F -(�sr Qj �, the marked depth. '� �Ii 1r Note: End of tubing must contact stop. �' / 6. Insert appropriate Viega jaw into the pressing tool and '�" /� push in, holding pin until it locks in place. E 9 7.Open the jaw and place at right angles on the fitting. Visually check insertion depth using mark on tubing. 8.Start pressing process and hold the trigger until the jaw V iega ProPress Insertion Depth Chart has engaged the fitting. Tube Size 1/2" 3/4" 1" 11/4" 11/2" 2" 9.After pressing, the jaw can be opened again. Insertion Depth 3/4" 7/s" '/s" 1" 17/16" 19/16" Leak Testing with Smart Connect : Cid Unpressed connections are located by = pressurizing the system with air or water. When testing with water the proper pressure range is 15 psi to 85 psi maximum. Leak testing with air can be dangerous at high pressures.When testing with compressed air the proper pressure range is 1/2 psi to 45 psi maximum. Following a successful leak test,the system may be pressure tested up to 200 psi with air,or up to 600 psi with water,if required by local code requirements or project specifications. Viega LLC,12303 Airport Way,Ste.395• Broomfield,CO 80021• Ph:800-976-9819• Fax:800-976-9817 SM-PP 1017 3 of 23 Submittal viega 9 Package V iega ProPress°XL (Copper) For Types K, L and M Hard Copper Tubing in 21/2"to 4" /A A WARNING Read,understand and follow all instructions for installing ProPress XL(copper)fittings.Failure "`I : '� to follow all instructions may result in extensive property ________________. damage,serious injury or death. __ /4_ ,, 1. Cut copper tubing at right angles using displacement- s � r type cutter or fine-toothed steel saw. 1 2111111 2. Keep end of tubing a minimum of 4" away from the contact area of the vise to prevent possible damage to the tubing in the press area. $10 3. Remove burr from inside and outside of tubing to prevent NM (�� it 1 11� � cutting sealing element. 4. Check seal and grip ring for correct fit.Do not use oils or 10°1t4.■ ��1 Iif lubricants.Use only ProPress Shiny Black EPDM sealing �w � .. elements. � 5. Illustration demonstrates proper fit of grip ring,separation 1ring and sealing element. 4 6 6. Mark proper insertion depth as indicated by the ProPress XL(copper) Insertion Depth Chart.Improper insertion o depth may result in an improper seal. Cif � oI Ej 7. While turning slightly, slide press fitting onto tubing to the 4r` , • Y# < 7 marked depth.End of tubing must contact stop. , Si % , O 1 8. ProPress XL(copper)fitting connections must be IN tt � �"� performed with ProPress XL-C Rings and V2 ACTUATOR. qb t#�� ` Use of ProPress XL Rings and/or Actuator(for Bronze \� fittings)will result in an improper connection.See Ridgid 7 8 9 1 Operator's Manual for proper tool instructions. 9. Open XL-C Ring and place at right angles on the fitting. XL-C Ring must be engaged on the fitting bead.Check insertion 7& *''',- depth. �`, I® 10. With V2 ACTUATOR inserted into the tool,openthe V2 �� ° — �;, ACTUATOR as shown and connect V2 ACTUATOR to the N-401o, � 10,, — Ile ���Ta XL-C Ring. CO,' % - .../ 11. Place V2 ACTUATOR onto XL-C Ring and start pressing r ,,,b process.Hold the trigger until the Actuator has engaged 10 11 . _ 12 the XL-C Ring. Keep extremities and foreign objects away fro mXL-C Ring and V2 ACTUATOR during pressing operation to prevent injury or incomplete press. ProPress XL(copper)Insertion Depth Chart 12. Release V2 ACTUATOR fromXL-C Ring and then remove Tube Size 21/2" 3" 4" the XL-C Ring from the fitting on completion of press. Insertion Depth 111/16" 115/,x" 238" Remove tag from fitting,indicating press has been performed. Leak Testing with Smart Connect®:Unpressed connections are located by pressurizing the system with air or water.When testing with water the proper pressure range is 15 psi to 85 psi.Leak testing with air can be dangerous at high pressures.When testing with compressed air the proper pressure range is 1/2 psi to 45 psi. Following a successful leak test,the system may be pressure tested up to 200 psi with air,or up to 600 psi with water,if required by local code requirements or project specifications. Viega LLC,12303 Airport Way,Ste.395• Broomfield,CO 80021• Ph:800-976-9819• Fax:800-976-9817 SM-PP 1017 4 of 23 Submittal viega 9 Package Viega Limited Warranty ProPress° Fittings And Valves Subject to the conditions and limitations in this Limited warranty. The part or parts which you claim failed should Warranty, Viega LLC(VIEGA)warrants to wholesalers be kept and Viega contacted by writing to the address and licensed plumbing and mechanical contractors below or telep honing 1-800-976-9819 within thirty(30) in the United States and Canada that its PRO PRESS days after the leak or other failure and identifying yourself fittings, when properly installed in non industrial and as having a warranty claim. You should be prepared to non marine applications and under normal conditions ship,at your expense,the product which you claim failed of use, will be free of failure from manufacturing defect due to a manufacturing defect and document the date of for a period of fifty(50)years from date of installation installation.Within a reasonable time after receiving the and that its PROPRESS valves,when properly installed product,Viega will investigate the reasons for the failure, in non industrial and non marine applications and under which includes the right to inspect the product at Viega. normal conditions of use, will be free of failure from Viega will notify you in writing of the results of its review. manufacturing defect for a period of two(2)years from date of installation. In the event that Viega determines that the failure or leak was the result of a manufacturing defect in the part Under this Limited Warranty, you only have a right to a covered by this warranty and that this warranty applies, remedy if the failure or leak resulted from a manufacturing the EXCLUSIVE AND ONLY REMEDY under this warranty defect in the products covered by this warranty and the shall be the reimbursement for repair and/or replacement failure or leak occurred during the warranty period.You do of the part.VIEGA SHALL NOT BE LIABLE FOR ANY not have a remedy under this warranty and the warranty CONSEQUENTIAL OR OTHER DAMAGE(FOR EXAMPLE, does not apply if the failure or any resulting damage is WATER OR PROPERTY OR MOLD REMEDIATION) caused by(1)components other than those manufactured UNDER ANY LEGAL THEORY AND WHETHER or sold by Viega;(2)not designing, installing, inspecting, ASSERTED BY DIRECT ACTION,FOR CONTRIBUTION or testing the ProPress fittings or valves in accordance OR INDEMNITY OR OTHERWISE. with Viega's installation instructions in effect at the time of the installation;applicable code requirements; and THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER accepted industry practice; (3)improper handling and WARRANTIES, EXPRESS OR IMPLIED,INCLUDING protection of the product prior to and during installation, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF inadequate freeze protection, exposure to water pressures MERCHANTABILITY AND FITNESS FORA PARTICULAR or temperatures or in applications outside acceptable PURPOSE.If a limited warranty shall be found to apply, operating conditions;(4)acts of nature such as, but not such warranty is limited to four years.Other than this limited to,earthquakes, fire,flood,or lightning, or(5) Limited Warranty, Viega does not authorize any person external environmental causes,such as water quality or firm to create for it any other obligation or liability in variations, aggressive water, or other external chemical or connection with its products. physical conditions. This Limited Warranty gives you specific legal rights and In the event of a leak or other failure of the parts covered you also may have other rights which may vary from state by this warranty, it is the responsibility of the property to state.This warranty shall be interpreted and applied owner to obtain and pay for repairs. Only if the warranty under the law of the state in which the product is installed applies will Viega be responsible for the remedy under this and is intended as a Commercial Warranty. *Zero Lead identifies Viega®products meeting the lead free requirements of NSF 61-G through testing under NSF/ANSI 372(0.25%or less maximum weighted average lead content). Viega products are designed to be installed by licensed and trained plumbing and mechanical professionals who are familiar with our products'proper use and installation.Installation by non-professionals may void Viega LLC's warranty. This document subject to updates.For the most current Viega technical literature please visit www.viega.us. Viega LLC,12303 Airport Way,Ste.395• Broomfield,CO 80021• Ph:800-976-9819• Fax:800-976-9817 SM-PP 1017 23 of 23 Tube • Fittings • Valves COPPERTUBE FOR PLUMBINGAND MECHANICALAPPLICATIONS Job Name Contractor Job Location Wholesaler Engineer Streamline® Rep Product Description: Streamline®CopperTube for use in plumbing and mechanical applications.Available sizes(Type K,L,M,& DWV)ranging from %"to 8"in diameter.All tube shall be manufactured in the United States. Material: Streamline®CopperTube is manufactured from UNS C 12200 grade of copper. Key Specifications: Streamline®CopperTube(Type K,L,M) shall conformto the NSF/ANSI 6 I Annex G requirements and is manufactured to meet ASTM B88.Copper drainage tube(DWV)is made to meet ASTM B306.Copperrefrigeration coils,ACR/Nitrogenized straight lengths and line sets are made to meet the chemical, mechanical,cleanness and eddy currenttesting requirements of the applicable specifications of ASTM B280. Installation: Installations shall comply with the latest applicable building codes for the local jurisdiction.For detailed installation instructions, consult the Copper Developement Association at copper.org. References: ASTM B75 Seamless CopperTube C 12200 99.9% Pure Copper(can be used for potable water) NSF/ANSI 61 Annex G SafeDrinkingWaterAct(third par tycertifcation) ASTM B88 Seamless CopperWater and GasTube(Type K,L,M) ASTM B280 Seamless CopperTubeforAir Conditioning and Refrigerants ASTM B306 Seamless DrainageTube Code (DWV) Copper(tube or fitting]UNS C122000 has been evaluated by NSF International to NSF/ANSI 61 for use in drinking water supplies of pH 6.5 and above. Drinking water supplies that are less than pH 6.5 may require corrosion control to limit leaching of copper into the drinking water. MADE IN USA A BRAND OF MUELLER INDUSTRIES Distributed by Mueller Streamline Co.•8285 Tournament Drive,Memphis,TN 38125•800-348-8464•www.muellerindustries.com page 1 of 4 44_ _i/t IzamhileJ, Tube • Fittings • Valves COPPERTUBE DATA Streamline®Copper Tube sets the standard for quality,consistency and service in the plumbing industries. With a full line of coppertube productsto support most all plumbing supply and DWV applications,Streamline®Copper Tube is available in all common types including Type K,Type L,Type M and DWV. Each piece of tube is incised marked and color coded for easy,long lasting identity. Manufactured in accordance with applicable standards,our ongoing commitment to quality continues to make Streamline®Copper Tube the preferred and specified brand of industry professionals. T ' E K RATED WORKING PRESSURECPSIG) _ NI ,,.DIA. WT/FT FT/BNDL 150°F 200°F _ 300°F 400°F I/' 0.145 500 913 860 842 537 3/8 0.269 500 960 904 885 565 1/2 0.344 500 758 713 698 446 5/8 0.418 200 626 589 577 368 3/4 0.641 200 724 682 668 426 I 0.: • 100 557 524 513 327 11/4 1.04 100 452 425 416 266 11/2 1.36 100 420 396 387 247 2 2.06 - 370 348 341 217 21/2 2.93 - 338 319 312 199 3 4.00 328 308 302 193 3 1/2 5.12 - 311 293 286 183 4 6.51 - 306 288 282 180 5 9.67 - 293 276 270 172 6 13.90 - 295 277 271 173 8 25.90 - 14 295 289 184 TYPE L 1/4 0.126 500 775 729 714 456 3/8 0.198 500 662 623 610 389 1/2 0.285 500 613 577 565 361 5/8 0.362 200 537 z 495 316 3/4 0.455 200 495 466 456 291 I 0.655 100 420 395 387 247 1 1/4 0.884 100 373 351 344 219 1 1/2 1.14 100 347 327 320 204 2 1.75 - 309 291 1:5 182 21/2 2.48 - 285 269 26 168 3 3.33 - 270 254 248 159 3 1/2 4.29 - 258 243 238 152 4 5.38 - 249 235 230 147 5 7.61 - 229 215 211 35 6 10.2 - 213 201 196 1 8 19.3 - 230 216 212 135 Tables give computed allowable stress for annealed copper tube at indicated temperature. Distributed by Mueller Streamline Co.•8285 Tournament Drive,Memphis,TN 38125•800-348-8464•www.muellerindustries.com page 2 of 4 11111111111116„.111111141111111 , I - Tube • Fittings • Valves COPPERTUBE DATA TYPE M RATED WORKING PRESSURE(PSIG) NOM.DIA. WT/FT FT/BNDL 150°F 200°F 300°F 400°F 3/8 0.145 500 485 456 447 285 1/2 0.204 500 420 395 387 247 3/4 0.328 200 346 326 319 204 I 0.465 100 286 270 264 169 I 1/4 0.682 100 287 271 265 169 1 1/2 0.94 100 282 265 259 166 2 1.46 - 254 239 234 149 2 1/2 2.03 - 233 219 215 137 3 2.68 - 215 _ 203 199 127 3 1/2 3.58 - 214 202 197 126 4 4.66 - 213 201 197 126 5 6.66 - 198 186 182 116 6 8.92 - 186 175 171 109 8 16.5 - 195 183 180 115 'F.Y.P_E DWV NOM. WT/FT 1 FT/BNDL 150°F 200°F 300°F 400°F 11/4 . 100 280 269 258 165 11/2 0.809 00 249 240 230 147 2 1.07 - 185 178 170 109 3 1.69 - 130 125 80 4 2.87 - 127 2 117 75 5 4.43 - 129 124119 76 6 6.1 - 126 121 74 8 10.6 - 124 119 114 Table give computed allowable stress for annealed copper tube at indicated temperature. TECHNICAL DATA Values of allowable internal working pressure for coppertube in service are based on the formula from ANSI B3 I, Standard Code for Pressure Piping: 2 S tm P = D max-0.8 tm P= Allowable Pressure @150°F S = 5100 PSIG annealed S= Allowable stressD max-0.8 tm ©200°F S= 4800PSIG annealed T= Wall thickness @ 300°F S= 4700 PSIG annealed D Max= Outside Diameter @ 400°F S= 3000 PSIG annealed All ratings listed for types K,L,M, DWV and refrigeration servicetube in the preceding charts are calculated for tube in the annealed condition.These values should be used when soldering,brazing or welding is employed forjoining components in a system.While the ratings for hard drawntube are substantially higher,they should only be used for systems using properly designed flare or compression mechanical joints, since joining by any heating process might anneal (soften)the tube. In designing a system,careful consideration should also be given to joint ratings as well as those of the components. A BRAND OF MUELLER INDUSTRIES M Distributed by Mueller Streamline Co.•8285 Tournament Drive,Memphis,TN 38125•800-348-8464•www.muellerindustries.com page 3 of 4 Tube • Fittings • Valves COPPERTUBEAND SOLDERTYPEFITTINGS I. Cut tube squar ewith the cutter or fine hack - I. Cut tube to length&remove saw(32 tooth blade is recommended). bur rwith file or scraper. Remove Burr. 2. Clean outside end of copper tube thoroughly �'• with sand cloth or sandpaper equal depth of fitting.Leave no darkspots. 2. Clean outside of tube with 3. Clean inside of fitting carefully to tube stop with sandpaper or sand cloth. wire brush.Note:Sand cloth or sandpaper may also be used. • 4. Using a brush,apply light uniform coat of solder ingflux to the outside of the tube and inside of the fitting. 3. Clean inside of fitting with wire t- brush,sand cloth or sandpaper. 5. Slip tube into fitting to tube stop.Turn tube r back and forth once or twice to distribute �r flux evenly. r 6.Apply heat uniformly ar oundthe fitting with 4.Apply flux thoroughly to torch. When solder melts upon contact with inside of fitting. heated fitting,the proper solder ingtemperature ,441/� r� has been reached. Remove flame and feed 11* cps solder slightly off center at the bottom of the joint.Pr oceedacr ossthe bottom of the fitting and up to the top center position. Return to the starting point,and then proceed up the 5.Apply flux thoroughly to incomplete side to the top,again,overlapping outside of tube-assemble the solder metal. Wipe off surplus solder with l tube and fitting. a piece of cloth. CAUTION: No not overheat the joint or direct the flame into the face of the fitting cup. Overheating could burn the I 6.Apply heat with torch.When flux, which w ill destroy its effectiveness solder melts upon contact with and the solder w ill not enter the joint %WIP6 heated fitting,the proper temp properly. P for soldering has been reached. Remove flame&feed solder to the joint at one or two points until a ring of solder appears at the end of the fitting. Distributed by Mueller Streamline Co.•8285 Tournament Drive,Memphis,TN 38125•800-348-8464•www.muellerindustries.com page 4 of 4 Page 1 of 5 NitaNG.: FREEDOM') RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK494(K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page wwwvikinggroupinc.com 1. DESCRIPTION Viking Freedom° Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired.The orifice design, with a K-Factor of 4.9 (70.6 metric*),allowsthe sprinkler'sefficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installedflush to the ceiling.The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off" design of the concealed cover - plateassemblyallowseasy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking '1 the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts.The ENT finish is only availablefor the sprinkler assembly,the cover plate is not plated. t. 2. LISTINGS AND APPROVALS c0as UL Listed (C-UL-US-EU):Category VKKW eu Refer to the Approval Chartsand Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure:Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) GI ass-bul bfl uid temperature rated to-65 °F (-55°C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 Deflector Pins: Stainless Steel UNS-S30200 Button:Brass UNS-C36000 Pip Cap and Insert Assembly:Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke:UNS-S43000 Stainless Steel or Phosphor Bronze UNS-C51000 Bell evil I eSpring Sealing Assembly:Nickel Alloy,coated on both sides with PTFE Tape Cover Adapter:Cold Rol ledSteel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover PlateAssembly:Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400 Spring: BerylliumNickel Solder:Eutectic Ordering Information: (Also refer to the current Viking price I ist.) Viking Freedom° Residential Concealed Pendent SprinklerVK494 and Cover PlateAssemblymust be ordered separately: Sprinkler: Order Sprinkl erVK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix:Brass=A and ENT= JN Temperature Suffix:155 °F (68°C) = B,200 °F (93 °C)= E For example,sprinkler VK494 with a Brass finish and a 200 °F (93°C)temperature rating= Part No. 20759AE. Standard Cover Plates: Base Part No. 13504 (2-3/4"diameter), Base Part No. 13642 (3-5/16"diameter), or Base Part No. 15394 (square cover plate,3-5/16") Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4"diameter)or Base Part No. 21875 (3-5/16"diameter). Form No. F_012116 18.04.12 Rev 18.1 ReplacesForm No. F_012116 Rev 17.2 (added stainless steel cover plates) Page 2 of 5 FREEDOM') RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK494(K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page wwwvikinggroupinc.com Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix:Pol ished Chrome=F,Brushed Chrome=F-/B,Bright Brass=B,Antique Brass=B-/A,Brushed Brass=B-/B,Brushed Copper= E-/B,Painted White= M-/W,Painted Ivory= M-/I, Painted Black= M-/B Temperature Suffix: 135°F/57°C=A For example,cover 13504 with a Polished Chrome finish and a 135 °F/57°C temperature rating= 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: A. Heavy Duty Part No. 14047W/B**(availablesince 2006), or B. Head Cabinet Wrench Part No. 14031*** (availablesince 2006) C. Optional Concealed Cover Plate Instal lerTool Part No. 14412 (availablesince 2007) D. Optional Large Concealed Cover Plate Instal lerTool Part No. 14867 (avail abl esince 2007) **Requires a 1/2"ratchet(not avail abl efrom Viking).***AI so optional for removal of the protective cap.Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (availablesince 1971) 4. INSTALLATION Refer to appropriate NFPA InstallationStandards. 5. OPERATION During fire conditions,when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly.. Water flowing through the sprinkler orifice strikes the deflector,forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS,TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY Viking SprinklerModel VK494 is avail abl ethrough a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGSAND FINISHES Sprinkler Sprinkler Maximum Temperature Rating Cover Large Square Temperature Nominal Ambient of the Cover Plate Cover Plate Cover Plate Bulb Color Classification Temperature Ceiling Assembly Base Part Base Part Base Part Rating' Temperature2 (Required)3 Number' Number' Number' Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) 13504 or 13642 or 15394 Red 218766 218756 Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C) 13504 or 13642 or 15394 Green 218766 218756 Sprinkler Finishes: Brass and ENT Cover Plate Finishes6: Polished Chrome, Brushed Chrome, Bright Brass,Antique Brass,Brushed Brass,Brushed Copper,Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatingss: ENT Footnotes 1. The sprinkler temperature rating is stamped on the deflector. 2. Based on NFPA-13,NFPA 13R, and NFPA 13D. Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction.Refer to specific instal l ationstandards. 3. Maximum ambient temperature for cover assemblyis 100°F(38°C). 4. Part number shown is the base part number.For compl ete part number,refer to current Viking price I ist schedul e. 5. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent al l possible corrosive environments.Prior to instal l ation,verify through the end-user that the coatings are compatiblewith or suitable for the proposed environment.For automatic sprinklers,the ENT coating is applied to all exposed exterior surfaces,including the waterway. For ENT coated sprinklers,the Bell evil I e spring is exposed. 6. Stainless Steel versions are not avail abl ewith any finishes or paint. Form No. F_012116 18.04.12 Rev 18.1 Page 3 of 5 FREEDOM') RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK494(K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page wwwvikinggroupinc.com Approval Chart Viking VK494,4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Water Wor- Part Number 1 Inches mm U.S. metric 2 king Pressure 20759 VK494 1/2 15 4.9 70.6 175 psi(12 bar) Max.Coverage Flow Pressure Listings and Minimum Area 6 GPM PSI(bar) Approvals35 W X L (LPM) Deflector to Installation pp Spacing Ceiling Type Ft. Ft.X Ft. 155°F(68°C), 200°F(93°C)Temperature u 4 (m X m) Rated Sprinklersiu cOas (m) 12 X 12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14 X 14 13 7.0 (4.3 X 4.3) (49.2) (0.48) Conceal ed with See Footnotes 7,9, 10, 16 X 16 13 7.0 Refer to Figure 2 Cover PI ate &11 8 (4.9 X 4.9) (49.2) (0.48) Assembly. (2.4) 18 X 18 17 12.0 See Footnote 8. (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 (6.1 X 6.1) (75.7) (1.15) Footnotes 1. Part number shown is the base part number. For compl ete part number,refer to current Viking price schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3. This chart shows the listings and approval savail abl eat the time of printing. Other approval smay be in process. Check with the manufacturer for any additional approvals. Refer al so to Design Criteria. 4. Listed by Underwriter's Laboratories,Inc.for use in the U.S.,Canada,and European Union. 5. Meets New York City requirements,effective July 1,2008. 6. For areas of coverage smallerthan shown,use the"Flow"and"Pressure"for the next larger area listed. Fl owsand pressures listed are per sprinkler. The distance from sprinklers to wal I sshal I not exceed one-half the sprinkler spacing indicated for the minimum"Fl ow"and"Pressure"used. 7. Cover Temperature Rating is 135°F(57°C).Cover Part No. 135041, 136421(I argediameter),or 15394'(square cover pl ate). 8. Other paint col orsare avail abl eon request with the same I istings as the standard finish colors. Stainless Steel cover plates are not avail ablewith any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information.Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 9.Accepted Cover PI ate Finishes are:Polished Chrome,Brushed Chrome,Bright Brass,Antique Brass,Brushed Brass,Brushed Copper,Painted White,Painted Ivory,or Painted Black8. 10.C-UL-US-EU Listed as corrosion resistant-El ectrol essNickel PTFE(ENT) 11.Stain!essSteel Cover pl atetemperature rating is 135°F(57°C).Stainless Steel Cover Part Numbers:218761 and 218751(I argediameter). Form No. F_012116 18.04.12 Rev 18.1 Page 4 of 5 NitaNG.: FREEDOM') RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK494(K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page wwwvikinggroupinc.com DESIGN CRITERIA (Al so refer to the Approval Chart on page 3.) UL Listing Requirements(C-UL-US-EU)_ When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R,applythe listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13:The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers.The minimum required discharge from each of the four sprinklers is to be the greater of the fol I owing: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R appl icationsfor each I isted area of coverage,or • Cal cul atedbased on a minimum discharge of 0.1 gpm/sq.ft.over the"design area"in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft.(2.4 m). NOTE:Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT:Always refer to Bulletin Form No. F 080415-Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly 2-1/4" (57 mm) • Protective cap removed • Use wrench 14047W/B** diameter opening required in the ceiling. Sprinkler Wrench Part No. 14047W/B** .... rimrii i ill --- I Step 1: Step 2: t Carefully slide the Carefully press the wrench upward and wrench sideways around turn slightly to ensure engagement with the deflector and pins the sprinkler wrench flats. Sprinkler - wrench flat NEVER install the sprinkler by applying the installation r Sprinkler wrench across the frame arms. DO NOT overtighten. . Cf. / frame arms Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B**or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. R Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required(Not available from Viking) Form No. F_012116 18.04.12 Rev 18.1 Page 5 of 5 N!KING® FREEDOM') RESIDENTIAL TECHNICAL DATA CONCEALED PENDENT SPRINKLER VK494(K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page wwwvikinggroupinc.com 1/2" (15 mm) NPT 2-9/16" (65 mm) Maximum 2-1/16" (52 mm) IL Minimum t T_ i, qi 4 ` r NCO . LC) _ ! - •i... i i I-4 2-3/4"(70 mm) or pi.2-3/4" NOTE: Upon sprinkler activation, the deflector descends 3-5/16"(84 mm) to approximately 13/16"(21 mm)below the sprinkler body. Figure 2: Sprinkler Dimensions and Cover Installation QQ�0 CUs TOGA > �Z O 0 U� O -b. VIKING All custom color painted cover plates will have an i identifying I abelaffixed to the inside of the cover that indicates the custom color and will have a representative , 3-5/16"(84 mm) 11 sample(a paint dot)of the paint on the I abel. Figure 3: Identification of Custom Paint for Concealed Covers Figure 4: Square Cover Assembly 15394 Form No. F_012116 18.04.12 Rev 18.1 ReplacesForm No. F_012116 Rev 17.2 (added stainless steel cover plates) ES-A-LF2000B Job Name Contractor Job Location Approval Engineer Contractor's P.O.No. Approval Representative LEAD FREE _ Series LF2000B Double Check Valve Assemblies Sizes: 1" - 2" (15 - 60mm) „1 '�� ' Series LF2000B Double CheckValve Assemblies shall be installed Q� at referenced cross-connections to prevent the backflow of polluted 3/4" LF2000B water into the potable water supply. Onlythosecross-connections (20mm) identified by local inspection authorities as non-health hazard shall be allow edth e use of an approved double ch eckvalve assembly. Checkwith local authority having jurisdiction regarding vertical Approvals orbntation,frequency of testing or other instalation requirements. �pSSIF,�O Th esevalves meet the requirements of ASSE Std. 1015 and AVVWA Std.C510 and are approved bytheFourrdationfor Cross- 055E GO G® O C � US Correction Control and Hydraulic Research at the University of cus 3 1015 864.5 /4"-2" Southern California.Th e LF2000B features Lead Free*construction (LBV Models Only) to comply with Lead Free*installation requirements. Approved by the Foundation for Cross-Connection Control and Hydraulic Research Features at the University of Southern California. • Ease of maintenance with only one cover LBV models not listed. • Top entry Available Models • Replaceable seats and seat discs • Modular construction Suffix: • Compact design B — Quarter turn ball valves • 1/2"-2" (15-50mm)Lead Free*cast silicon copper alloy LBV— less ball valves body construction • Top mounted ball valve test cocks Pressure-Temperature • Low pressure drop Temperature Range:33°F-140°F (0.5°C-60°C) • No special tools required Maximum Working Pressure: 175 psi(12.06 bar) • 1/2"- 1" (15-25 mm)havetee handles Standards Specifications AWWA Std.C510, IAPMO PS31 A Double Check Valve Assembly sh all be installed at each noted location.The Double Check Valve Assemblies shall be constructed NOTICE using Lead Free*materials. Lead Free*valves sh all comply with The information contained h ereinis not intended to replace th e state codes and standards,wh ereapplicable, requiring reduced full product installation and safety information available or the lead content.Th eassembly shall consist of two positive seating experience of a trained product installer.You are required to check modules with captured springs and rubber seat discs.The thoroughly read all installation instructions and product safety check module seats and seat discs shall be replacesb le.Service information before beginning the installation of th is product. of all internal components shall beth ro ugha single access cover secured with stainless steel bolts.The assembly sh all also include *Th ewetted surface of this product contacted by consumable water two resilient seated isolation valves and four top mounted, resilient contains less than 0.25%of lead by weight. seated test cocks.Th e assemb ly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by th e Fourelation for Cross-Connection Control and HydraUic Research at the University of Southern Califomia.Assembly shall be an Ames Company Series LF2000B. Ames Fire&Waterworks product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measure- ments,please contact Ames Fire&Waterworks Technical Service.Ames Fire&Waterworks reserves th erigh tto ch angeor modify product design,construction, specifications,or materials without prior notice and with oufncurring any obligation to make such changes and modifications on Ames Fire&Waterworks products previously or subsequently sold. A WATTS Brand Dimensions -Weights .A �6, 11111 451 . _, 7 c � � 0 0 [ q"..."/ ■, -mmm)■- \ '-- min H F G LF2000B SIZE(DN) DIMENSIONS WEIGHT A B C F G H I in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 1/2 15 10 254 4% 117 27/6 62 5 127 3% 85 25/6 59 21/6 52 4.5 2 3/4 20 111/2 282 4 102 31/4 79 6%6 157 3'/6 87 212 54 15/6 33 5 2.3 1 25 131/4 337 512 130 4 102 712 191 33/2 85 111/6 43 111/6 43 12 5.4 114 32 16% 416 5 127 35/6 84 91/2 241 5 127 3 76 2 50 15 6.8 11/2 40 16% 425 4' 124 31/2 89 93/4 248 513/6 148 3/ 79 211A6 68 15.86 7.2 2 50 191/2 495 61/4 159 4 102 13% 340 6% 156 37/6 87 211/6 68 25.75 11.7 Strainer sold separately Capacities As compiled from documented Foundation for Cross-Connection Control and Hydraulic Research at the University of South ern kP a psi 11/4"(32mm) California lab tests.*Typical maximum system flow rate(7.5 feet/ A 96 14 sec.,2.3 meters/sec.) 0 83 12 kPa psi '/2"(15mm) 0 69 10 2) 8312 y 55 8 O 69 1041 6 ' 55 8 w .• 41 6 4 2 {_ y28 4 a N 14 2 0 0 0. 0 0 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 2 4 6 8 10 12 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm AP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm 5 7.5 10 15 fps 5 7.5 10 fps 1.5 2.3 3.0 4.6 mps 1.5 2.3 3.0 mps Flow Rate Flow Rate kP a psi s " kP a psi 11/2"(40mm) A /4 (20mm) A m 152 22 83 12 co 0 69 10 3 124 18 0 55 8 ;v 96 14 6 1N 69 10 W 28 4 is 41 6 0 14 2 a 14 2 /------ a 0 0 APO 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 5 10 15 20 25 30 35 40 45 50 gpm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm AP 0 19 38 57 76 95 114 133 152 171 190 1pm 5 7.5 10 15 fps 7.5 15 fps 1.5 2.3 3.0 4.6 mps 2.3 4.6 mps Flow Rate Flow Rate y kP a psi A 1"(25mm kP a psi A H 110 16 2"(50mm) ) w 83 12 0 83 12 0 69 10 J O 69 10 J 55 8 3 55 8 i 41 6 m 28 4 H 28 4 ii 14 2 0. 14 2 - 0. 0 0 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm 0 25 50 75 100 125 150 175 200 gpm AP 0 19 38 57 76 95 114 133 152 171 190 209 2281pm AP 0 95 190 285 380 475 570 665 760 Ipm 5 7.5 10 15 fps 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 1.5 2.3 3.0 4.6 mps Flow Rate Flow Rate A WATTS Brand USA:Backflow Tel:(978)689-6066•Fax:(978)975-8350•AmesFireWater.com USA:Control Valves Tel:(713)943-0688•Fax:(713)944-9445•AmesFireWater.com Canada: Tel:(905)332-4090•Fax:(905)332-7068•AmesFireWater.ca Latin America: Tel:(52)81-1001-8600•AmesFireWater.com ES-A-LF2000B 1322 ©2018 Ames Fire&Waterworks INSTALLATION INSTRUCTIONS 1-247 Series 247 FireLockTM Residential Zone Control Riser Module Assembly A WARNING • Wr ^ 0 0 ❑ ❑ 0. • Read and understand all instructions before attempting to install any Victaulic piping products. .❑ �•T' o I.a • Depressurize and drain the piping system before attempting to install, remove,adjust, or maintain any Victaulic Scan QR Code for Access to piping products. VideouInstallation blications,andsMoreons, • Wear safety glasses, hardhat,and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. Waterflow Pressure Gauge Pressure Detector Shutoff Valve Gauge i –•/i' l' (,' \) Module Body , u FromWater-111111� jlrg.li r NA� _ic 0I' PP"ToSprinkler Supply Distribution ( ) 7 ' . To Building Drain-4111—I-1 0(:)/(IL:_-9 I \C) __ Test/DrainValve ` I Shutoff Valve I� Thum bScrew INSTALLATION OF THE SERIES 247 The Series 247 FireLock Residential Zone Control Riser Module 1. Install the Series 247 into the system using Victaulic couplings for includes the module body,a U Lor U LC Listed and FM Approved grooved-end pipe.Always refer to the instructions,supplied with waterflow detector,a pressure gauge with shutoff valve(provision for the coupling,for complete installation requirements. draining),and an alarm test module available with different orifice sizes 2. For the NPT threaded drain outlet,follow standardin practices (K-factors). In addition, an optional pressure relief valve kit is available. p p g to make the threaded connection. NOTE:The nominal drain size is Refer to the"Installation of the Optional Pressure Relief Valve Kit" 1 inch/25 mm.The drawings,shown on page 2, provide examples section. of alternative ways to make the threaded drain connection with NOTE CONCERNING WATERFLOW DETECTOR INSTALLATION AND a street elbow to avoid interference with couplings on the water MAINTENANCE INSTRUCTIONS VERSUS RISER MANIFOLDS, AS supply side and sprinkler distribution side of the module body. STATED FROM THE WATERFLOW DETECTOR MANUFACTURER: "The 3. Apply thread sealant to the threads of the pressure gauge. Install section'Installation Guidelines' suggests mounting the detector at least the pressure gauge into the module body,as shown in the drawing 6 inches/152 mm from a fitting that changes the direction of water flow above.Make sure the face of the gauge is visible. and no less than 24 inches/610 mm from a valve or drain.This is a general statement that is superseded when a riser manifold assembly 4. Connect the water-flow detector to the alarm system in accordance is listed or approved by agencies such as U Land/or FM.The agency with the instructions supplied. approval takes precedence because this configuration has been tested 5. To install the optional pressure relief valve,follow the instructions and its operation validated." in the"Installation of the Optional Pressure Relief Valve Kit" section. NOTICE 6. Perform the system flow test,as outlined in the"System Flow • The Series 247 can be installed in eitherthehorizontal(left- Test"section. to-righ tor right-to-left flow)or vertical(up)position.The flow direction arrow SHALL point toward the sprinkler distribution,as shown in the drawing above. ✓ctaulic° 1-247 1-247/Series 247 FireLockTM Residential Zone Control Riser Module Assembly/ Installation Instructions EXAMPLES OF ALTERNATIVE WAYS TO MAKE THE THREADED DRAIN CONNECTION The following drawings provide examples of alternative ways to make the threaded drain connection to avoid interference with couplings on the water supply side and sprinkler distribution side of the module body.NOTE:The Series 247 with optional pressure relief valve kit is shown below. diI II •i rolls Irti Ips 0 ® I o I b.�ju-" NMI u I 1. II Il q s'i'V ell 11- o lamI . � (-1_1 7 OR\6 7- 1 `F-4• 141.411k X1I•n 011 Li 1 When installing a street elbow directly into the drain port,the street elbow shall be threaded into the drain port before the Series 247 is installed into the system with grooved pipe and grooved pipe couplings. I ®i ;Voles 0 17. Ain u ° ' mute -. .--.. en lip, ,,, o . ra,, ,,,,,.,,0 , I, J'; — loy If the Series 247 was installed in the system before the connection to the drain port was made, install a close nipple and a straight coupling before installing the street elbow. SYSTEM FLOW TEST A WARNING 2. Turn the thumb screw on the handle of the"Test/Drain Valve" counterclockwise. Place the handle of the"Test/Drain Valve"in the • DO NOT operate the"Test/Drain Valve"under pressure.Verify "Test"position. that th a"Sh utoff Valve"is in the"Closed"position before 3. Place the"Shutoff Valve"in the"Open"position. operating the"Test/Drain Valve." 4. Verify that the water-flow detector is operating properly and that Failure to follow these instructions could result in serious personal the alarms have sounded. injury and property damage. 5. When the system flow test is complete,place the"Shutoff"valve in the"Closed" position. Notify the authority having jurisdiction, remote station alarm monitors, 6. Place the"Test/Drain Valve"back to the"Drain"position. Hand- and anyone in the affected area that the system flow test is being tighten the thumb screw on the handle. conducted. 1. Before performing the system flow test,confirm that all valves are in their normal operating positions("Shutoff Valve"in "Closed" position,"Test/Drain Valve"in "Drain"position,and pressure gauge shutoff valve in "Open"position). ✓ctaulic° 1-247_2 REV D 1-247/Series 247 FireLockTM Residential Zone Control Riser Module Assembly/ Installation Instructions PRESSURE RELIEF VALVE KIT OPTION The following instructions apply to a Series 247 with pressure relief valve installed in either the horizontal(left-to-right or right-to-left flow)or vertical (up)position.The pressure relief valve is rated to 175psi/1206kPa/12 Bar. 1/2-inch NPT Hose Clamp Threads o 4 1114 PTV) Pressure Relief Valve Barbed • DrainTubing 1 Fitting ro , I. An , D , _ _ za - Co U Close Nipple" ��� ® "'p1 �� ��e 3/s inch NPTr�) — Ptr�,.., ipp Threads Hose Clamp n (—) n _ Barbed Fitting PressureRelief Elbow 'hi" Valve Port = I 10571� ('/2-inch NPT) j : :141111111111-11100i 14...-- Drain Port (3/8-inch NPT) INSTALLATION OF THE PRESSURE RELIEF VALVE KIT OPTION 2. Remove the plugs from the 3/cinch NPT drain port and the' -inch ACAUTION NPT pressure relief valve port.Refer to the drawings above. • Shutoff valves SHALL NOT be located between the Series 247 3. Apply thread sealant to the threads of the close nipple and with pressure relief valve kit and the building drain. pressure relief valve. • The pressure relief valve SHALL be unrestricted in order to 4. Install the close nipple into the drain port,as shown above. dischargeto the drain. 5. Install the pressure relief valve into the pressure relief valve port, Failure to follow these instructions could cause improper operation, as shown above. resulting in property damage. 6. Connect the drain tubing from the drain port's close nipple to the pressure relief valve using the barbed fittings and hose clamps provided. 1. Verify that all instructions in the"Installation of the Series 247" section have been followed. 7. Follow all steps in the"System Flow Test"section. 4tauiic° 1-247_3 INSTALLATION INSTRUCTIONS 1-247 Series 247 FireLockTM Residential Zone Control Riser Module Assembly For complete contact information,visit victaulic.com 1-247 5375 REVD UPDATED 10/2016 2000247M02 jctaulic° VICTAULIC AND FIRELOCK ARE REGISTERED TRADEMARKS 0 R TRADEMARKS 0 FVICTAULIC CO MPANYAND/O R ITS AFFILIATED ENTITIES IN THE UNITED STATES AND/O ROTHERCO UNTRIES. 0 2016 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RING HANGERS 4NvAL Fig. CT-69 Adjustable Swivel Ring Size Range:'/2"through 4" Material:Carbon steel Finish:Copper plated sr Service:Recommended for suspension of non-insulated stationary copper tube. ? Approvals:Complies with Federal S pecification A-A-1192A(Type 10) 1 WW-H-171-E(Type10),ANS I/MS SS P-69 and MSS S P-58(Type10). Features: ' • Threads are countersunk so that they cannot become burred or damaged. +. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut will not fall off. Ordering:S pecifynominal tube size,figure number,name and finish. Note:Metric nut available upon request. -,- y �3/8n - f 3/8" 1 iniiiii i ..% F1 ti B li C 4.0,) G 1/2'through 11/4"pipe G 11/2'through 4"pipe FIG. CT-69:DIMENSIONS (IN) • LOADS(LBS) • WEIGHT (LBS) Tube Size Max Load Weight B C F G Width 1/2 0.10 3 23/6 1% 3/4 0.10 213/6 2 19/6 1 0.10 211/16 113/6 11/4 5 11/4 300 0.10 21/2 15/8 15/6 /8 11/2 0.10 211/6 113/6 1 2 0.11 37A6 21/2 11/2 21/2 0.25 313/6 215A6 1116 3 525 0.27 41/4 33/8 17/8 3/4 4 650 0.48 43/8 31/2 11/2 Note:Reflects changes in rod diam eterfrom previously published data per recent revisions in MSS-SP-58&69 PROJECT INFORMATION APPROVAL STAMP Project: ❑ Approved Address: 0 Approved as noted Contractor: ❑ Not approved Engi neer: Remarks: Submittal Date: Notes 1: Notes 2: PH-11.11 Fire and Emergency Services 2399 N. Frontage Road W. Vail, Colorado 81657 TOWN N A[ VA 1 1 ' Tel: 970-479-2252 VY IY U f YN 1 L www.vailgov.com Fire& Emergency Services Fire Marshal FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min)stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: Office Use: 4872 Meadow Lane Project#: (Number) (Street) (Suite#) Building Permit#: Building/Complex Name: Primary Sprinkler Permit#: Contractor Information: Lot#: Block# Subdivision: Company: Arapahoe Fire Protection Company Address: 11901 E 14th Ave Detailed Description of Work: Provide new residential Aurora CO 80010 fire sprinkler system in single family residence. City: State: Zip: Contact Name: Ron Lumsden (use additional sheet if necessary) Contact Phone: 303-366-4905 x210 E-Mail ron@arapahoefire.com Detailed Location of Work: I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate sprinkler sys- Does a Monitored Fire Alarm Exist? Yes( No( v tem working plan, and state that all the information as required is correct. I agree to comply with the information and sprinkler system Does a Sprinkler System Exist? Yes( ) No( tel working plans,to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdi- Work Class: vision codes, design review approval, National Fire Protection Asso- ciation 13, International Building and Residential Codes and other New F. Addition (I-` Remodel ( 1 Repair(fl ordinances of the Town applicable thereto. Retro-Fit Q—' Other(r X Type of Building: Contractor Signature(required) Single-Family E. I Duplex(I7 Multi-Family L) Commercial f) Restaurant n Other(moi Property Information Parcel#: 14-A Complete Valuation for Fire Sprinkler Permit: (For parcel#,contact Eagle County Assessors Office at 970-328-8640 or Fire Sprinkler$: 41742.00 visit www.eaglecounty.us/patie) Tenant Name: Date Received: Owner Name: 2014-0916 VEIL FJF(F-. D3 0' TOWN OF VAIL ' Fire& Emergency Services •4Re<�SE ,y��. MCY _ Town of Vail Fire Permit Fee Schedule Instructions for calculating FIRE ALARM or SPRINKLER permit fees (see applicable section below): 1. Determine the valuation (labor &materials) 2. See base Permit Fee (flat fee) 3. Calculate the Plan review fee (multiply the valuation by the applicable percentage listed) Fire Alarm: Permit Fee: 3.75% of the valuation Plan Review Fee: $288.00, due at permit submittal OTHER Fire Permit Fees: • Permits issued under a Scope of Work letter shall be assessed a fee not less than $144.00 and may be increased at a rate of$72.00 per hour for inspections, revisions, and similar elements. • Re-inspections and plan review for re-submittals shall be billed at $72.00 per hour. • Operational Permits, Special Event Permits, and Construction Permits other than those required for Fire Alarm and Fire Sprinkler systems, issued under provisions of the International Fire Code shall be based on an hourly rate of$72.00 per hour per person for site inspections, plan review and permit processing. Fire Sprinkler: Permit Fee: 4.25% of the valuation Plan Review Fee: $432.00, due at permit submittal 11901 East 14th Ave. 1 SI; X Aurora,CO 80010 303-366-4905 Fax 303-366-4966 PRu1VJ�jOM Illi ❑ 95 Talamine Court Colorado Springs,CO 80907 719-244-9523 Fax 719-559-2874 Town of Vail 75 South Frontage Rd Vail, CO 81657 Attn: Fire P Ian Review Subject: Design Department Introduction Arapahoe Fire is very proud to have grown our design capabilities from two designers in 2009 to nine designers today. I am the design manager at Arapahoe and have been with the company since 2009. I am a NICET level IV technician with almost 22 years of experience doing all manner of fire sprinkler systems. We have a level III designer in our Colorado Springs branch who is the lead designer in that office. We also have two other designers who are currently working towards their level III certificates. The other 5 designers are at various stages of their careers,most with less than 5 years of experience. Arapahoe Fire also has two professional engineers on staff. One who does design as well as reviews and one who works in sales in addition to his review duties. I perform regular training classes for our entire team as well training of new design staff as we bring them on board. I look forward to working with everyone there in Vail and am excited to bring another quality fire protection project to life with your help. Sincerely, r?T1 ----- ------------- Ron Lumsden Arapahoe Fire Protection Inc. Design Manager