F18-0032_approved documents_1528733116.pdf
75 South Frontage Road Fire -Construction Permit West, TOWN OFVAIL F18-0032 Vail, CO 81657 Issued: 06/11/2018 TOWN of VAIL Office:970.479.2139 InspectionLine:970.479.2149 Property Information Address: 429 8 N UGGET LN(210 11230 70 36)(210 11230 70 36) Unit#: ParcelNumber: 210 11230 70 36 LegalDescription: Subdivision: BIGHORN ESTATES Lot: 1 Contacts ContactType: Applicant Full Name: Clint Janssen Address: P.O.Box 1055 P.O. Box 1055 Vail,CO 81658 Phone: 9709145014 ContactType: PropertyOwner Ful I Name: 4298 NUGGETLANE LLC Address: Phone: None Contractor Contractor Type: Fire Protection Company: Vail Valley Fire SprinklerCorp State License#:CO-49 1 Phone: 970-914-5014 Projectlnformation ProjectName: 4298 Nugget Lane LLC 2016 ProjeciDescription: Install new residential fire sprinklersystem per all international and local codes. DuplexSide B 4298 Nugget Lane. Fees Paid Account#:001-0000.31111.04 Fire SuppressionPermitFee Fee Amount: $1,062.50 Account#:001-0000.21123.00 Fire SuppressionReviewFee Fee Amount: $432.00 TotalPaid: $1,494.50 Conditions Issued By: Town ofVailFire and EmergencyServices Department NOTICE: By issuance of this Permitthe applicantagrees to complyto all Titles of the Townof Vail Code and all applicable State and Federal law. Failure to do so will void this Permitand the applicantshall forfeitall applicable fees. VAIL VALLEY FIRE SPRINKLER CORPORATION VAIL VALLEY FIRE SPRINKLER CORP. 57 HEREFORD LANE EDWARDS, CO 81632 PH: (970)914-5014 NUGGET LANE DUPLEX 4298 NUGGET LANE VAIL, CO 81657 5/7/2018 HYDRAULIC CALCULATIONS 'jl * FIRE PROTECTION DESIGN,INC. 13147 BIRCH WAY,THORNTON,CO 80241{3031 920.0941 PAUL D.HUBBARD-NICET III-#108221 7 Hydraulic Calculations for Project Name: NUGGET LANE DUP LEX Location:4298 NUGGET LANE,VAIL, COLORADO 81657, Drawing Name: 4298 Nugget Lane.cad Calculation Date:5/7/2018 Design Remote Area Number: 1 Occupancy Classification: Residential Density: 0.100gpm/ft2 Area of Application: 298.38ft2(Actual 298.38ft2) Coverage per Sprinkler: 144.00ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 4 Type of System: Volume of Dry or PreAction System: N/A In-rack Demand: N/Agpm at Node: N/A Hose Streams: 0.0 gpm at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 65.87 @ 128.933 Water Supply Information: for Node: 1 Date: 03/14/2018 Location: Source: VAIL VALLEY FIRE SPRINKLER Name of Contractor: VAIL VALLEY FIRE SPRINKLER CO Address: 57 HEREFORD LANE,EDWARDS, CO 81632 Phone Number: (970)914-5014 Name of designer: PAUL HUBBARD. Authority Having Jurisdiction: TOWN OF VAIL Notes: ,©M.E.P.CAD, Inc. diAutoSPRINK® 12 v12.1.1.0 1 5/7/201811:36:43AM Page 1 } Hydraulic Summary Job Number:180301-429 8-Remote Area 1 Re•ort Descri.tion:Residential 1 Job Job Number Design Engineer 180301-4298 PAUL HUBBARD. Job Name: State Certification/License Number NUGGET LANE DUPLEX 108221 Address 1 AHJ 4298 NUGGET LANE TOWN OF VAIL Address 2 Job Site/Building VAIL,COLORADO 81657 Address 3 Drawing Name 4298 Nugget Lane.cad System Remote Area(s) Most Demanding Sprinkler Data Occupancy Job Suffix 4.9 K-Factor 14.40 at 8.636 Residential Remote Area 1 Hose Allowance At Source Density Area of Application 0.00 0.100gpm/ft2 298.38ft2(Actual 298.38ft2) Additional Hose Supplies Number Of Sprinklers Calculated Coverage Per Sprinkler Node Flow(gom) 4 144.00ft2 Total Hose Streams 0.00 System Flow Demand Total Water Required(Including Hose Allowance) 65.87 65.87 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 24.18 between nodes 12 and 13 Maximum Velocity Under Ground 7.01 between nodes 1 and 2 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 48.36ga1 Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node Name (gpm) (psi) (psi) @ (gpm) (psi) @ (gpm) (psi) (psi) 1 Water Supply 145.000 120.000 1404.00 144.913 65.87 128.933 15.980 Contractor Contractor Number Contact Name Contact Title 028 CLINT JANSSEN Name of Contractor. Phone Extension VAIL VALLEY FIRE SPRINKLER CO (970)914-5014 Address 1 FAX 57 HEREFORD LANE Address 2 E-mail EDWARDS,CO 81632 blazeinvail@aol.com Address 3 Web-Site L� ©M.E.P.CAD,Inc. AutoSPRINK®12 v12.1.1.0 5/7/2018 11:37:58AM Page 1 Hydraulic Graph Job Name: NUGGET LANE DUPLEX N 1.85 Remote Area Number: 1 Date:5/7/2018 150 i 1 Static Pressure 145.000 Water Supply 65.87 @ 144.913 Summary Sheet 135 Node: 1 65.87 @ 128.933 • 1404.00 @ 120.000 120 105 90 .N 2 75 -'System demand curve a 60 45 30 15 0 111111111 111111 1 1 1 1 1 1 1 i I I I I 1111 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 111111111 0300 600 900 1200 1500 1800 2100 2400 2700 3000 Flow-gpm &M,©M.E.P.CAD, Inc. III% AutoSPRINK®12 v12.1.1.0 5/7/2018 11:36:44AM Page 2 .74 r Summary Of Outflowing Devices 1 Job Number:180301-4298-Remote Area 1 r t +• - Report Description:Residential(1) Actual Flow Minimum Flow K-Factor Pressure Device (qpm) (qpm) (K) (psi) y Sprinkler 101 14.40 14.40 4.9 8.636 Sprinkler 102 14.66 14.40 4.9 8.951 Sprinkler 103 17.58 14.40 4.9 12.869 Sprinkler 104 19.23 14.40 4.9 15.405 * Most Demanding Sprinkler Data E,©M.E.P.CAD,Inc. In AutoSPRINK®12 v12.1.1.0 5/7/2018 11:36:45AM Page 3 Job Name: NUGGET LANE DUPLEX Remote Area Number: 1 Date: 5/7/2018 Supply Analysis Static Residual F low Available Total Demand Required Pressure Node Name (psi) (psi) C° (gpm) (psi) @ (gpm) (psi) 1 Water Supply 145.000 120.000 1404.00 144.913 65.87 128.933 Node Analysis Node Number Elevation(F oot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 1 -0-0 Supply 128.933 65.87 101 21-10 Sprinkler 8.636 14.40 102 21-10 Sprinkler 8.951 14.66 103 21-5 Sprinkler 12.869 17.58 104 21-5 Sprinkler 15.405 19.23 2 -3-1 125.195 3 -1-7 124.478 4 3-9 9 8.706 5 9-1 95.371 7 9-1 84.815 8 9-1 46.067 12 20-0 30.759 13 21-9 17.380 14 21-9 13.812 15 22-5 9.722 16 22-5 8.804 17 22-5 9.133 18 21-9 13.285 19 21-9 15.920 LM,©M.E.P.CAD, Inc. di AutoSPRINK®12 v12.1.1.0 5/7/2018 11:36:46AM Page 4 Job Name: NUGGET LANE DUPLEX Remote Area Number: 1 Date:5/7/2018 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) Length) Fitting Pf Friction Elev Pe ( ) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. (See 0-7 150 8.636 Route 1 101 21-10 4.9 14.40 3/4 Sprinkler, Notes) 2-0 -0.258 16 22-5 14.40 0.8110 2-7 0.164213 0.426 E(2-0) 16 22-5 1 (See 9-2 150 8.804 Notes) 11-0 0.045614 E(3-0),T(8-0) 15 22-5 14.40 1.0550 20-2 0.918 15 22-5 66+ 14.66+ 14 1 (See 8-8 150 9.722 Notes) - Flow(q)from Route 2 and 2 14-0 0.302 and 2 and 2 - 0.167194 2E(3-0),T(8-0) 14 21-9 29.06 1.0550 22-8 3.787 14 21-9 58+ 17.58+ 17 1 (See 0-11 150 13.812 Notes) - Flow(q)from Route 3 and 3 8-0 0.000 and 3 and 3 13 21-9 46.64 1.0550 8 11 0.401134 3.567 T(8-0) 13 21-9 23+ 19.23+ 19 1 (See 5-7 150 17.380 Notes) Flow(q)from Route 4 and 4 11-0 0.748 and 4 and 4 0.759799 - E(3-0),T(8-0) 12 20-0 65.87 1.0550 16-7 12.631 12 20-0 1 (See 10-11 150 30.759 Notes) 3-0 4.733 0.759799 2E(-0.000),E(3-0) 8 9-1 65.87 1.0550 13-11 10.575 8 9-1 1 (See 26-0 150 46.067 Notes) 25-0 0.759799 - 2E(3-0),Tr(3-0),2T(8-0) 7 9-1 65.87 1.0550 51-0 38.748 7 9-1 11/4 (See 19-2 150 84.815 Notes) 18-0 0.284267 2Tr(2-0),2T(7-0) 5 9-1 65.87 1.2910 37-2 10.556 5 9-1 11/2 (See 5-4 150 95.371 Notes) 3-0 2.295 0.125499 BOR,f(-0.000),Tr(3-0) 4 3 9 65.87 1.5270 8-4 1.041 4 3-9 11/2 (See 5-4 150 98.706 Notes) 16-0 2.325 0.125499 3Tr(3-0), BFP(-5.766), 3 -1-7 65.87 1.5270 21-4 23.447 f(-0.000),P R V(-15.000), BaIV(7-0) 3 1-7 2 1-6 150 124.478 0.666 2 -3-1 65.87 2.0090 0.032993 1-6 0.051 &©M.E.P.CAD,Inc. id AutoSPRINK®12 v12.1.1.0 1 5/7/2018 11:36:48AM Page 5 Job Name: NUGGET LANE DUPLEX Remote Area Number: 1 Date:5/7/2018 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) Length) Fitting Pf Friction Elev Pe ( ) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. 2 -3-1 2 (See 124-0 150 125.195 Notes) 12-0 -1.337 1 -0-0 65.87 1.9590 0.037302 2E(3-6),T(5-0),GV,S 136-0 5.075 0.00 128.933 Hose Allowance At Source 1 65.87 Total(Pt) Route 1 (See 0-7 150 8.951 Route 2 102 21-10 4.9 14.66 '/4 Notes) Sprinkler, 2-0 -0.258 17 22-5 14.66 0.8110 2-7 0.169736 0.441 E(2-0) 17 22-5 1 (See 1-6 150 9.133 Notes) 11-0 -0.000 15 22-5 14.66 1.0550 12-6 0.047148 0.589 E(3-0),T(8-0) 9.722 Total(Pt) Route 2 0-4 150 12.869 Route 3 103 21-5 4.9 17.58 3/, (See Notes) Sprinkler, 2-0 -0.130 18 21-9 17.58 0.8110 2-4 0.237474 0.546 E(2-0) 18 21-9 1 (See 2-0 150 13.285 Notes) 6-0 0.065964 E(3-0),Tr(3-0) 14 21-9 17.58 1.0550 8-0 0.528 13.812 Total(Pt) Route 3 (See 0-4 150 15.405 Route 4 104 21-5 4.9 19.23 '/4 Sprinkler, Notes) 2-0 -0.130 19 21-9 19.23 0.8110 2-4 0.280474 0.645 E(2-0) 19 21-9 1 (See 7-9 150 15.920 Notes) 11-0 -0.000 0.077908 E(3-0),T(8-0) 13 21-9 19.23 1.0550 18-9 1.460 17.380 Total(Pt) Route 4 &©M.E.P.CAD,Inc. ill AutoSPRINK®12 v12.1.1.0 1 5/7/2018 11:36:48AM Page 6 Job Name: NUGGET LANE DUPLEX Remote Area Number: 1 Date:5/7/2018 Equivalent Pipe Lengths of Valves and Fittings(C=120 only) T—IC Value Multiplier II Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor ( Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45°Elbow Eel 11'/4° Elbow Ee2 22'/2°Elbow _ f Flow Device fd Flex Drop FDC Fire Department Connection _ fE 90° FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flq Flange FN Floating Node fT FireLock(TM)Tee q Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° I Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap - &©M.E.P.CAD,Inc. di AutoSPRINK®12 v12.1.1.0 1 5/7/2018 11:36:48AM Page 7 Hydraulic Calculations for Project Name: NUGGET LANE DUP LEX Location:4298 NUGGET LANE,VAIL, COLORADO 81657, Drawing Name: 4298 Nugget Lane.cad Calculation Date:5/7/2018 Design Remote Area Number: 2 Occupancy Classification: Residential Density: 0.100gpm/ft2 Area of Application: 175.79ft2(Actual 175.79ft2) Coverage per Sprinkler: 224.00ft2 Type of sprinklers calculated: Pendent No. of sprinklers calculated: 2 Type of System: Volume of Dry or PreAction System: N/A In-rack Demand: N/Agpm at Node: N/A Hose Streams: 0.0 gpm at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 45.31 @ 116.620 Water Supply Information: for Node: 1 Date: 03/14/2018 Location: Source: VAIL VALLEY FIRE SPRINKLER Name of Contractor: VAIL VALLEY FIRE SPRINKLER CO Address: 57 HEREFORD LANE,EDWARDS, CO 81632 Phone Number: (970)914-5014 Name of designer: PAUL HUBBARD. Authority Having Jurisdiction: TOWN OF VAIL Notes: ,©M.E.P.CAD, Inc. diAutoSPRINK® 12 v12.1.1.0 2 5/7/201811:39:46AM Page 1 1-93;e. Hydraulic Summary Job Number:180301-4298-RemoteArea2 t + - Report Descri.tion:Residential 2 Job Job Number Design Engineer 180301-4298 PAUL HUBBARD. Job Name: State Certification/License Number NUGGET LANE DUPLEX 108221 Address 1 AHJ 4298 NUGGET LANE TOWN OF VAIL Address 2 Job Site/Building VAIL,COLORADO 81657 Address 3 Drawing Name 4298 Nugget Lane.cad System Remote Area(s) Most Demanding Sprinkler Data Occupancy Job Suffix 4.9 K-Factor 22.40 at 20.898 Residential Remote Area 2 Hose Allowance At Source Density Area of Application 0.00 0.100gpm/ft2 175.79 ft2(Actual 175.79 ft2) Additional Hose Supplies Number Of Sprinklers Calculated Coverage Per Sprinkler Node Flow(qpm) 2 224.00ft2 Total Hose Streams 0.00 System Flow Demand Total Water Required(Including Hose Allowance) 45.31 45.31 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 16.63 between nodes 20 and 21 Maximum Velocity Under Ground 4.82 between nodes 1 and 2 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 48.36ga1 Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node Name (gpm) (psi) (psi) @ (gpm) (psi) @ (gpm) (psi) (psi) 1 Water Supply 145.000 120.000 1404.00 144.956 45.31 116.620 28.336 Contractor Contractor Number Contact Name Contact Title 028 CLINT JANSSEN Name of Contractor. Phone Extension VAIL VALLEY FIRE SPRINKLER CO (970)914-5014 Address 1 FAX 57 HEREFORD LANE Address 2 E-mail EDWARDS,CO 81632 blazeinvail@aol.com Address 3 Web-Site L� ©M.E.P.CAD,Inc. AutoSPRINK®12 v12.1.1.0 5/7/2018 11:39:17AM Page 1 Hydraulic Graph Job Name: NUGGET LANE DUPLEX N 1.85 Remote Area Number:2 Date:5/7/2018 150 _1 1 i 1 Static Pressure 145.000 Water Supply 45.31 @ 144.956 Summary Sheet 135 Node: 1 120 1404.00 @ 120.000 45.31 @ 116.620 105 90 .N 3 75 a System demand curve 60 45 30 15 0 -um 111111111 111111 1 1 1 1 1 1 1 1 1 1 1 1 111111111 111111 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 0300 600 900 1200 1500 1800 2100 2400 2700 3000 Flow-gpm LM,©M.E.P.CAD, Inc. III% AutoSPRINK®12 v12.1.1.0 5/7/2018 11:39:48AM Page 2 .74 r Summary Of Outflowing Devices 1 Job Number:180301-4298-Remote Area 2 r t +• - Report Description:Residential(2) Actual Flow Minimum Flow K-Factor Pressure Device (qpm) (qpm) (K) (psi) y Sprinkler 201 22.40 22.40 4.9 20.898 Sprinkler 202 22.91 22.40 4.9 21.861 b Most Demanding Sprinkler Data E,©M.E.P.CAD,Inc. In AutoSPRINK®12 v12.1.1.0 5/7/2018 11:39:50AM Page 3 Job Name: NUGGET LANE DUPLEX Remote Area Number: 2 Date: 5/7/2018 Supply Analysis Static Residual F low Available Total Demand Required Pressure Node Name (psi) (psi) C° (gpm) (psi) @ (gpm) (psi) 1 Water Supply 145.000 120.000 1404.00 144.956 45.31 116.620 Node Analysis Node Number Elevation(F oot) Node Type Pressure at Discharge at Notes Node Node (psi) (gpm) 1 -0-0 Supply 116.620 45.31 201 28-9 Sprinkler 20.898 22.40 202 28-9 Sprinkler 21.861 22.91 2 -3-1 115.417 3 -1-7 114.726 4 3-9 91.235 5 9-1 88.419 6 9-1 84.442 9 9-1 71.335 10 19-3 61.920 11 19-3 38.578 20 29-2 29.36 7 21 29-2 23.534 22 29-2 21.617 23 29-2 22.619 LM,©M.E.P.CAD, Inc. lard AutoSPRINK®12 v12.1.1.0 5/7/2018 11:39:53AM Page 4 Job Name: NUGGET LANE DUPLEX Remote Area Number:2 Date:5/7/2018 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) Length) Fitting Pf Friction Elev Pe ( ) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. (See 0-5 150 20.898 Route 1 201 28-9 4.9 22.40 3/4 Sprinkler, Notes) 2-0 -0.172 22 29-2 22.40 0.8110 2-5 0.371875 0.891 E(2-0) 22 29-2 1 (See 12-7 150 21.617 Notes) 6-0 0.103297 E(3-0),Tr(3-0) 21 29-2 22.40 1.0550 18-7 1.917 21 29-2 22.91 1 (See 6-4 150 23.534 Notes) Flow(q)from Route 2 9-0 20 29-2 45.31 1.0550 15-4 0.380275 5.833 3E(3-0) 20 29-2 1 (See 9-11 150 29.367 Notes) 3-0 4.299 0.380275 2E(-0.000),E(3-0) 11 19-3 45.31 1.0550 12-11 4.912 11 19-3 1 (See 25-5 150 38.578 Notes) 36-0 0.380275 - 3T(8-0),2Tr(3-0),2E(3-0) 10 19-3 45.31 1.0550 61-5 23.342 10 19-3 1 (See 10-2 150 61.920 Notes) 3-0 4.408 0.380275 - 2E(-0.000),E(3-0) 9 9-1 45.31 1.0550 13-2 5.007 9 9-1 1 (See 15-6 150 71.335 Notes) 19-0 0.380275 2T(8-0),Tr(3-0) 6 9-1 45.31 1.0550 34-6 13.107 6 9-1 11/2 (See 11-11 150 84.442 Notes) 16-0 0.142274 2T(7-0),Tr(2-0) 5 9-1 45.31 1.2910 27-11 3.977 5 9-1 11/2 (See 5-4 150 88.419 Notes) 3-0 2.295 0.062812 BOR,f(-0.000),Tr(3-0) 4 3 9 45.31 1.5270 8-4 0.521 4 3-9 11/2 (See 5-4 150 91.235 Notes) 16-0 2.325 0.062812 - 3Tr(3-0),BFP(-4.825), 3 -1-7 45.31 1.5270 21-4 21.166 f(-0.000), PRV(-15.000), BaIV(7-0) 3 1-7 2 1-6 150 114.726 0.666 2 -3-1 45.31 2.0090 0.016513 1-6 0.025 L,©M.E.P.CAD,Inc. lin AutoSPRINK®12 v12.1.1.0 2 5/7/2018 11:39:56AM Page 5 Job Name: NUGGET LANE DUPLEX Remote Area Number:2 Date:5/7/2018 Pipe Information Elev 1 Flow added Fittings& Length C Factor Total(Pt) Notes Node 1 K-Factor this step Nominal ID Devices (Foot) Fitting/Device(Equivalent (Foot) (q) Length) Fitting Pf Friction Elev Pe ( ) Fixed Pressure Losses,when Elev 2 Total Flow Equiv. (Foot) Loss Per Unit applicable,are added directly Node 2 Actual ID Length Total (Foot) (Q) (Foot) (psi) Friction(Pf) to(Pf)and shown as a (Foot) negative value. 2 -3-1 2 (See 124-0 150 115.417 Notes) 12-0 -1.337 1 -0-0 45.31 1.9590 0.018669 2E(3-6),T(5-0),GV,S 136-0 2.540 0.00 116.620 Hose Allowance At Source 1 45.31 Total(Pt) Route 1 202 28-9 4.9 22.91 3/4 (See 0-5 150 21.861 Route 2 Notes) Sprinkler, 2-0 -0.172 23 29-2 22.91 0.8110 2-5 0.387705 0.9 29 929 E(2-0) 23 29-2 1 (See 0-6 150 22.619 Notes) 8-0 21 29-2 22.91 1.0550 8-6 0.107694 0.915 T(8-0) 23.534 Total(Pt) Route 2 LHS,©M.E.P.CAD,Inc. di AutoSPRINK®12 v12.1.1.0 2 5/7/2018 11:39:56AM Page 6 Job Name: NUGGET LANE DUPLEX Remote Area Number:2 Date:5/7/2018 Equivalent Pipe Lengths of Valves and Fittings(C=120 only) T—IC Value Multiplier II Actual Inside Diameter 4.87 Value Of C 100 130 140 150 =Factor ( Schedule 40 Steel Pipe Inside Diameter Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve I DeIV Deluge Valve DPV Dry Pipe Valve E 90°Elbow EE 45°Elbow Eel 11'/4° Elbow Ee2 22'/2°Elbow _ f Flow Device fd Flex Drop FDC Fire Department Connection _ fE 90°FireLock(TM)Elbow fEE 45° FireLock(TM)Elbow flq Flange FN Floating Node fT FireLock(TM)Tee q Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° I Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap - &©M.E.P.CAD,Inc. di AutoSPRINK®12 v12.1.1.0 2 5/7/2018 11:39:56AM Page 7 VAIL VALLEY FIRE SPRINKLER CORPORATION 57 HEREFORD LANE EDWARDS, CO 81632 PH: (970)914-5014 NUGGET LANE DUPLEX 4298 NUGGET LANE VAIL, CO 81657 5/7/2018 EQUIPMENTSUBMITTAL rErPrQ Y Y Y FIRE PROTECTION DESIGN,INC 13147 BIRCH WAY,THORNTON,CO S0241(363]920-0941 PAUL D.HUBBARD NICET III-#108221 VicoWorldwide Fire Protection Contacts www.tyco-fire.com Products RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and D r yPipe Systems General The Series LFII Residential Concealed Pendent Sp rinklers (TY3596) has Description been designed with heat sensitivity and water distribution characteristics TYCO RAPID RESPONSE Series LFII p roverto help in the controlofresiden- Residential 4.9K Concealed Pendent tial fires and to imp rovethe chance for Sp rinklers (TY3596) are decorative, occupants to escape or be evacuated. 401.1 fast resp onse,fusible solder sp rinklers The Series LFII Residential Con- designed for use in residential occu- cealed Pendent Sp rinklers(TY3596) _--- p ancies such as homes, apartments, are ship p ed with a Disposable Pro- dormitories,and hotels. tective Cap. The Protective Cap is The cover p late assembly conceals temp orarily removed for installation, the sp rinkler operating components and then it can be rep laced to help abovethe ceiling.The flat profile of the protect the sprinkler while the ceiling NOTICE coverplate provides the optimum aes is being installed or finished. The tip of thetically ap p ealingsp rinkler design. the Protective Cap can also be used The Series LFII Residential Concealed In addition, the concealed design of to mark the center of the ceiling hole PendentSprinklers(TY3596)described the Series LFII Residential Concealed into p laster board, ceiling tiles, etc. herein must be installed and main- Pendent Sp rinklers(TY3596) provides by gently p ushing the ceiling p roduct tained in compliance with this docu- 1/2 inch (12,7 mm)vertical adjustment. against the Protective Cap.When the ment and withtheapplicablestandards This adjustment p rovidesa measure of ceiling installation is complete the Pro- of the NationalFire Protection Associa- flexibility when cutting fixed sprinkler tective Cap is removed and the Cover tion(NFPA),in additionto the standards drops. Plate Assembly installed. of any authorities having jurisdiction. Failure to do so may impair the perfor- The Series LFII Residential Concealed Dry Pipe System Application mance of these devices. Sprink lers are intended for use in the The Series LFII Residential Concealed following scenarios: Pendent Sp rinklersoffers a laboratory The owner is responsible for main- ap p roveabption fordesigning dry p ip e taining their fire protection system • wet and dry pip eresidential sp rin- residential sp rinklersystems,whereas, and devices in proper operating con- k ler systems for one-and two-fam- most residential sp rinklersare labora- dition. Contact the installing contrac- ily dwellings and mobile homes p er tory ap p rovedor wet systems only. tor or product manufacturer with any NFPA 13D questions. Through extensive testing, it has been • wet and dry pipe residential sprinkler determined that the number of design Sprinkler systems for residential occupancies sp rinklers(hydraulic design area) for p up to and including four stories in the Series LFII Residential Concealed height per NFPA13R Pendent Sp rinklers (TY3596) need Identification • wet and dry pipe sp rinklersystems not be increased over the number of w for thearyipep ortions any design sp rinklers (hydraulic design Number (SIN) residentialoccupancy per NFPA 13 area)as specified fo rwet pipe sprinkler systems,as is accustomed fordensity/ TY3596 area sp rinkler systems designed per NFPA 13. Consequently,the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non-water filled pipe in IMPORTANT addition to not having to increase the Always refer to Technical Data number of design sp rinklers(hydraulic Sheet TFP700 for the "INSTALLER design area)for systems designed to WARNING" that provides cautions NFPA13, 13D, or 13R. with respect to handling and instal- lation of sprinklersystemsand com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinklerto fail to operate in a firesituation or cause it to operate prematurely. Page 1 of 6 FEBRUARY 2015 TFP442 TFP442 Page 2 of 6 BODY SEALING WRENCH (1/2" NPT)— f p ASSEMBLY RECESS 0 , ���� _ lV ���� CAP 1 � SPRINKLER � Ithlt 1 WRENCHING Mr AREA SADDLE I — �H — PUSH WRENCH SUPPORT -------\11] COMPRESSION IN TO ENSURE CUP WITH "- _ SCREW ENGAGEMENT ROLLFORMED WITH SPRINKLER THREADS WRENCHING AR EA LEVER FIGURE 2 —n n l' W-TYPE18 GUIDESPRINKLER WRENCH PIN ID 1m 1 1 SOLDERLINK ELEMENT GUIDE PIN HOUSING DEFLECTOR b L_� (OPERATED DEFLECTOR POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREADINTO RETAINER SUPPORT WITH THREAD CUP UNTIL ) DIMPLES MOUNTING O O SURFACE IS FLUSH WITH CEILING LEJECTION SPRING / �—✓ SOLDER' COVER PLATE/RETAINER \ COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENTSPRINKLER(TY3596) _ 2-1/2" DIA. SPRINKLER- (63,5 mm) 1/2" (12,7 mm) FACEOF SUPPORT CUP 1/2" THREADED SPRINKLER ASSEMBLY NPT\ ADJUSTMENT FITTING / OPERATED == _ r r SPRINKLER\ II — i SS 1-7/8"+1/4" COVE JJ _ PLATE _ I (47,6 mm RETAINER lily 1/8" GAP ±6,4 mm) (3,2 mm) COVER PRINKLER- 1 7/8"(22,2 mm) I RETAINER SUPPORT CUP MOUNTING 1-1/8" (28,6 mm) ASSEMBLY ASSEMBLY 3/16" SURFACE \� I_�_ _�.I (4,8 mm) 3-3/16" DIA. DISPOSABLE DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER(TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP442 Page 3 of 6 Technical Design Criteria Dry Pipe System Water Delivery When using the Series LFII Residen- Data tial Concealed Pendent Sp rinklers TYCO RAPID RESPONSE Series LFII (TY3596)in dry pipe sp rinklersystems, Residential Concealed Pendent Sp rin- the time for water delivery must not Approvals klers(TY3596)areUL and C-UL Listed exceed 15 seconds forthe most remote UL and C-UL Listed for installation in accordance with this NYC Approved under MEA 44-03-E-2NSF operating sprinkler. Certified to NSF/ANSI61 section. Note: When conditions exist that are Obstruction to The TYCO RAPID RESPONSE Series LFII Water Distribution Residential Concealed Pendent Sp rinklers outside the scope of the provided cri S rink lers are to be located in accor- are only Listed with the Series LFII Con- feria,refer to the Residential Sprinkler dance with the obstruction rules of cealed Cover Plates having a factory-ap- Design Guide TFP490 for the manu- p liedfinish. facturer's recommendationsthat may NFPA 13D, 13R, and 13 as applicable Cover Plates can be ordered by following be acceptable to the authority having forresidentialsprinklers as well as with the instructions in the Ordering Procedure jurisdiction. the obstruction criteria describedwithin section. the Technical Data Sheet TFP490. Maximum Working Pressure System Types Operational Sensitivity 175 psi(12,1 bar) Per the UL Listing, wet p ip eand dry The sprinklersare to be installed rela- pipe systems may be utilized. Per the Discharge Coefficient C-UL Listing, only wet p ip esystems tive to the ceiling mounting surface as K=4.9 gp m/p sV (70,6 Ipm/bar1t2) may be utilized. shown in Figure 3. TemperatureRating Referto Technical Data Sheet TFP485 Sprinkler Spacing 160°F (71°C)Sp rinklerwith aboutthe use of residential sprinklers in The minimum sp acing between sp rin- 139°F (59°C)Cover Plate residential dry pipe systems. klers is 8 feet (2,4 m). The maximum Vertical Adjustment CeilingTypes sp acing between sp rinklers cannot 1/2 inch (12,7 mm) yp exceed the length of the coveragearea Smooth flat horizontal, or beamed, or n hydraulically sloped,in accordance with the 2013 (Ref.Table A or B) being ydraulicall y Refer to Ordering Procedure section. Edition of NFPA 13D, 13R, or 13 as calculated(e.g.,maximum 12 feet fora Physical Characteristics applicable. 12 ft.x 12 ft. coverage area,or 20 feet Body Brass for a 20 ft.x 20 ft. coveragearea). Hydraulic Design Cap Bronze The Series LFII must not be used Saddle Brass (NFPA13D and 13R) in applications where the air pres- Sealing Assembly Beryllium Nickel For systems designed to NFPA 13D sure above the ceiling is greater than w/TEFLON or NFPA 13R, the minimum required that below. Down drafts through the Soldered Link Halves Nickel sp rinkler flow rates are given in Support Cup could delay sprinkler Lever Bronze Tables A and B as a function of tern- Compression Screw Brass p erature rating and the maximum operation in a fire situation. Deflector Copper or allowable coverage areas. The Brass sp rinkler flow rate is the minimum Guide Pin Housing. Bronze required discharge from each of the Guide Pins Stainless Steel total number of"design sp rinklers"as or Bronze specified in NFPA 13D or NFPA 13R. Support Cup Steel The number of "design sp rinklers" Cover Plate Copper specified in NFPA13D and 13R forwet Retainer Brass pip esystems is to be applied when Cover Plate designing dry pipe systems. Ejection Spring Stainless Steel Hydraulic Design Operation (NFPA 13) M For systems designed to NFPA13, the When exposed to heat from a fire,the number of design sp rinklers is to be CoverPlate,which is normallysoldered the four most hydraulically demanding to the Sup p orCup at three oints,falls sp rinklers.The minimum required dis awayto exp osethe sp rinklerassemb ly. charge fro meach of the foursp rinklers At this point the Deflectorsup p ortedby is to be the greater of the following: the Arms drop sdown to its operated • the flow rates given in Tables A and position. The fusible link of the sp rin- B as a function of temperature rat- kler assembly is comprised of two link ing and the maximum allowab lecov- halves that are soldered together with erage area a thin layer of solder.When the rated • a minimum discharge of temperature is reached, the solder 0.1 gp m/ft.2 over the design area melts and the two link halves sep arate comp rised of the four (4) most allowing the sp rinkler to activate and hydraulically demanding sp rinklers flow water. for actual coverage areas p rotected by the four(4)sp rinklers The numb erof design sprinklers sp eci- fied in NFPA13 forwet pipe systems is to be applied when designing dry p ip e systems. TFP442 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure2,3 Maximum Maximum Coverage Spacing Ordinary Temp.Rating Minimum Area at 160°F (71°C) Ft.x Ft. Deflector to Installation Spacing (m x m) (m) Flow Pressure Ceiling Type Ft. gpm psi (m) (Ipm) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 13 7.0 inches (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed 16 x 16 16 13 7.0 Ceilings per 8 (4,9 x 4,9) (4,9) (49,2) (0,48) NFPA 13D or Concealed (2 4) 13R, or 13. Installed in 18 x 18 18 17 12.0 beam (5,5 x 5,5) (5,5) (64,3) (0,83) 7/8 to 1-1/8 inches below 20 x 20 20 20 16.7 bottom of (6,1 x 6,1) (6,1) (75,7) (1,15) beam Notes: 1. For coveragearea dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteriaare stated. 2. Requirement is based on minimum flow in gpm(Ipm)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Referto Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications,the greater of 0.1 gpm/ft?over the design area or the flow in accordance with the criteria in this table must be used. TABLE A W ET PI PE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLATPLATE CONCEALED PENDENT SPRINKLER(TY3596) NFPA 13D, 13R,AND 13 HYDRAULICDESIGN CRITERIA DRY PIPE SYST EM Minimum Flow and Residual Pressure 2,3 Maximum Maximum Coverage Spacing Ordinary Temp.Rating Minimum Area at 160°F (71°C) Ft.x Ft. Deflector to Installation Spacing (m x m) (m) Flow Pressure Ceiling Type Ft. gpm psi (m) (Ipm) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings - - 7/8 to 1-1/8 14 x 14 14 14 8.2 inches (4,3 x 4,3) (4,3) (53,0) (0,57) Beamed 16 x 16 16 15 9.4 Ceilings per 8 (4,9 x 4,9) (4,9) (56,8) (0,65) NFPA 13D or Concealed (2 4) 13R, or 13. Installed in 18 x 18 18 18 13.5 beam (5,5 x 5,5) (5,5) (68,1) (0,93) 7/8to 1-1/8 inches below 20 x 20 20 21 18.4 bottom of (6,1 x 6,1) (6,1) (79,5) (1,27) beam Notes: 1. For coveragearea dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteriaare stated. 2. Requirement is based on minimum flow in gpm(Ipm)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Referto Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications,the greater of 0.1 gpm/ft?over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT(TY3596) NFPA13D, 13R,AND 13 HY DRAULICDESIGN CRITERIA TFP442 Page 5 of 6 Installation Step 6. Screw on the Cover Plate Care must be exercised to avoid Assembly until its flange comes in damage before,during,and afterinstal- TYCO RAPID RESPONSESeries LFII contact with the ceiling. lation. Sp rinklers damaged by drop- Residential Concealed Pendent Sp rin- Do not continue to screw on the Cover ping, striking, wrench twist/slippage, klers (TY3596) must be installed in Plate Assembly such that it lifts a or the like,must be rep laced. accordance with this section. ceiling panel out of its normal position. The owner is resp onsible for the General Instructions If the Cover Plate Assembly cannot insp ectiontesting,and maintenanceof Damage to the fusible Link Assembly be engaged with the Mounting Cup theirfire protection system and devices during installation can be avoided by or the Cover Plate Assembly cannot in compliance with this document, as handling the sprink ler by the support be engaged sufficiently to contact the well as with the applicable standards Aso- cup only(i.e.,do not apply pressure to ceiling, the Sp rinkler Fitting must be of the National Fire Protection on t the fusible Link Assembly). repositioned. ciation (e.g., NFPA 25), in addition to the standards of any other authorities A 1/2 inch NPT sp rinklerjoint should be Care and having jurisdiction.Contact the install- obtained with a minimum to maximum ing contractoror p roductmanufacturer torqueof7 to 14 lbs.-ft.(9,5to 19,0 Nm). with any questions. Higher levels of torque may distort the Maintenance The owner must assure that the sp rin- sp rinklerinlet with consequent leakage TYCO RAPID RESPO NSE Series LFII klers are not used for hanging any or impairment of the sprinkler. Residential Concealed Pendent Sp rin- objects and that the sp rinklersare only Do not attempt to compensate for klers (TY3596) must be maintained cleaned by means of gently dusting insufficient adjustment in the Cover and serviced in accordance with this with a feather duster; otherwise,non- Plate / Retainer Assembly by under- section. operation in the event of a fire or inad- or over-tightening the Sp rinkler.Read- Beforeclosing a fire p rotectiorsystem vertent operation may result. just the position of the sp rinklerfitting main control valve for maintenance Automaticsp rinklersystemsshould be to suit. work on the fire p rotection system inspected,tested,and maintained bya Step 1. The sprinkler must only be which it controls, permission to shut qualified Inspection Service in accor- installed in the pendent position and down the affected fire protection dance with local requirements and/or with the centerline of the sp rinklerp er- system must be obtained from the national codes. pendicular to the mounting surface. proper authorities and all personnel Step 2. Remove the Protective Cap. who may be affected by this action must be notified. Step 3. With pipe thread sealant AbsenceofaCoverPlatemaydelaythe applied to the pipe threads,and using the W-Type 18 Wrench shown in Figure sp rinkleroperation in a fire situation. 2, install and tighten the Sp rinkler/ When properly installed, there is a Support Cup Assembly into the fitting. nominal 1/8 inch (3,2 mm) air gap The W-Type 18 Wrench will accept a between the lip of the Cover Plate and 1/2 inch ratchet drive. the ceiling, as shown in Figure 3. This Step 4. Replace the Protective Cap by air gap is necessary for proper op era p ushing it upwards until it bottoms out tion of the sp rinkler by allowing heat against the Support Cup.The Protec flow from a fire to pass below and tive Cap help s prevent damage to the above the Cover Plate to help assure Deflectorand Guide Pins during ceiling appropriate release of the Cover Plate installationand/orduring ap p licatiorof in a fire situation. If the ceiling is to be the finish coating of the ceiling. It may rep ainted after the installation of the also be used to locate the center of the Sp rinkler,care must be exercised to clearance hole by gently p ushing the ensurethatthe new p aintdoes not seal ceiling materialagainstthe center p oint off any of the air gap. of the Cap. Facto rypainted Cover Plates must not Note:As long as the protective Cap be rep ainted.Theyshould be rep laced, remains in place, the system is consid if necessary, by factory p ainted ered to be"Out Of Service." units. Non-factory app liedp aint may adversely delay or p revent sp rinkler Step 5. After the ceiling has been operation in the event of a fire. completed with the 2-1/2 inch (63 mm) Do not p ull the Cover Plate relative to diameter clearance hole and in p rep the Enclosure.Sep aratiormay result. aration for installing the Cover Plate Assembly, remove and discardthe Pro- Sp rinklers which are found to be tective Cap,and verifythat the Deflec- leaking or exhibiting visible signs of tor moves up and down freely. corrosion must be rep laced. If the sp rinklerhas been damaged and Automatic sp rinklers must never be the Deflector does not move up and p ainted,p lated,coated, or otherwise down freely, rep lacethe entiresprinkler altered after leaving the factory. Modi- assemb ly.Do not attempt to modify or fied or over heated sp rinklersmust be rep aira damaged sprinkler. rep laced. Bulletin 048Rev. A Model RFS42Rei _ bid) 00 Residential Flat Concealed Horizontal Sidewall Sprinkler (SIN RA4835) °° CD Coverage to 16 ft.x 20 ft.(4.9mx 6.1m) Features: 1. Flat cover plate (Solid or Perforated) for a flush, concealed wallfinish. 2. 4.2(60 metric) K Factor. 3. Sized to fit in a 31/2" or larger stud space even when installed directly in a TorqueSafeTM 90° Sprinkler Head Elbow** and several other common '/z" and 3/4" by 1/2" sprinkler fittings. 4. Push-on/pull-off flat cover plate. Application and Installation 5. Sprinkler shipped complete with factory installed protective cap. The Model RFS4prinkleris intendedforinstallation in the residential portions of any occupancy in accordance with 6. Sprinkler assembly and cover plate packaged NFPA 13, 13R& 13D.The sprinkler is listed as a Concealed separately. Residential Horizontal Sidewall Sprinkler using a smooth, 7. 1/" (3.2 mm)cover plate adjustment. flat, horizontal ceiling. System design and installation re- 8. Cover plate available, either solid or perforated, quirements for other ceiling configurations are described in in a wide variety of colors and finishes. NFPA 13, 13R or 13D, as applicable. Listings & Approvals The minimum listed spacing between Model RFS42 sprin- klers is 8 ft(2.4 m). 1. Listed by Underwriters Laboratories Inc. and The low flow RFS42RES sprinklers are specifically engi- UL certified for Canada (cULus). neered to meet the latest residential sprinkler listing stan- UL Listing Category dards(UL 1626 Standard).* Residential Automatic Sprinklers The sprinkler must be installed and properly oriented with the Model G6 Wrench,as follows: UL Guide Number Do not remove the factory installed plastic protective cap VKKW since it is sized to fit inside the G6 wrench. Note that the sprinklercan only mate when the sprinkler's deflectororien- Patents: tation tab(Fig. 1) is aligned with wrench's key-way. The G6 U.S. Patent No. 7,353,882, other Patents pending wrench is provided with bubble level pad and TOP mark- Product Description ing, to allowthe proper orientation of the horizontal sidewall The Reliable Model RFS42 Concealed Residential Extend- deflector. Final leveling can be done after leak proof joint is ed Coverage Horizontal Sidewall Sprinkler is an attractive, obtained with a minimumto maximumtorque of 8 to 18 ft-lbs concealed sprinkler assembly specially sized to fit within (11 to 24 N•m). Leave the protective cap on to protect the a 31/2" or larger stud space.The sprinkler uses a push-on/ sprinkler whilethe wall is plastered,wallpapered or painted. pull-off flat cover plate assembly. The sprinkler assembly is The protective cap must be removed and the listed cover shippedwitha protective cap. plate installed prior to the sprinkler system being placed in The flat cover plate is attached to the skirt using 135°F service.A2/8"(67 mm)diameterholemust becut inthe wall (57°C)ordinary temperature classification solder. The sprinfor the sprinkler assembly to extendthrough. kler is installed into the sprinkler fitting using the Model G6 Concealed cover plate/cup assemblies are listed only for Sprinkler Wrench. use with specific sprinklers. The use of any other concealed When the ambient temperature rises,the solder holding cover plate/cup assembly with the Model RFS42 Horizontal the cover plate melts,allowing the release of this part and Sidewall Sprinkler or the use of this dedicated concealed thus exposing the sprinkler inside to the rising ambient tem- cover plate assembly on any sprinkler with which it is not specifically listedwillvoid all guarantees,warranties, listings perature. and approvals. This sprinkler is listed fora maximumservice pressure of .175 psi(12,0 bar). * Effective date 3/14/2008 **Spears Manufacturing Company Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Technical Data: "K"Factor Sprinkler Maximum Orifice Thread Maximum Water Identification Size US Metric Size Ambient Working Pressure Number Approvals Temperature (SIN) 3/8"(9.6mm) 4.2 60 1/2" NPT(R1/2) 100°F(38°C) 175 PSI(12 bar) RA4835 cULus Listed Design Criteria*** Max.Coverage Area Deflector to Ceiling Flow Rate Pressure Temperature Rating Width x Length Dimension ft.x ft. m x m inches mm gpm L/min psi bar Sprinkler Cover 12 x 12 3.6 x 3.6 4-6 102- 152 12 45.4 8.2 0.57 12 x 12 3.6 x 3.6 6- 12 152-305 13 49.2 9.6 0.67 14 x 14 4.3x4.3 4-6 102- 152 12 45.4 8.2 0.57 14 x 14 4.3 x 4.3 6- 12 152 -305 14 53.0 11.1 0.78 165°F (74°C) 135°F(57°C) 16x16 4.9x4.9 4- 12 102 -305 16 60.6 14.5 1.01 16 x 18 4.9 x 5.5 4- 12 102-305 18 68.1 18.4 1.29 16 x 20 4.9x6.1 4-6 102- 152 22 83.3 27.4 1.92 16 x 20 4.9 x 6.1 6- 12 152 -305 23 87.0 30.0 2.10 ***For NFPA 13 systems calculate for a minimum design density of 0.1 gpm/sf, but in no case go below the Listed Design Criteria Flow Rate and Pressure. Material Data Bronze Sprinkler Body,Spring Closure Cap,Yoke,Lever, Slide Pin,Slide Plate,Deflector,Set Screw Brass Cover Plate,Sprinkler Sleeve, Frame Arms Stainless Steel Push Spring, Ball,Load Screw,Rivet Copper Plated Steel Cover Plate Skirt Nickel Alloy Fusible Element Nickel Alloy coated with PTFE Adhesive Tape Sealing Washer 2"± 1/16"[51MM± 1.6MM] %r Af- CEILING //4 DEFLECTOR ORIENTATION DEFLECTOR ORIENTATION TAB TAB a,�' 4-3/8"TO 12-3/8" f [111 TO 314MM] /"_ RECOMMENDED o o WALL HOLE it =� �.=�MI 1 2001 1� '1 nilDIAMETER &- - - SII ��- 2-5/8" I ,„.„. �R��g �y!�,[66.7MM] �__.r 4 PUSH ON/PULL OFF FLAT COVERPLATE TO 1/2"-14 NPT 3-5/16"[84.1MM] DIAMETER FRONT VIEW PUSH ON/PULL OFF FLAT COVERPLATE REMOVED - 3/16"[4.8MM] 1-3/8"±1/16" [34.6MM±1.6MM] *SEE LISTED DESIGN CRITERIA TABLE FOR FLOW RATE AND PRESSURE BASED ON DEFLECTOR TO CEILING DISTANCE. DEFLECTOR IS 3/8"[9.5MM]ABOVE CENTERLINE OF SPRINKLER. 04BFGOIG Fig. 1 2. Installation Guide for 31/2" or Larger Stud Space RFS42Residential Flat Cover Concealed Horizontal Sidewall Sprinkler SIN RA4835 CEILING CENTERLINE 1-3/8" �{ [35MM] ELBOW ,MINIMUM -- :41 CENRINECENTERLINE OF 3/8"T0731 2-3/8"2-5/8"[66.7MM] 1 MM 14MM] DIAMETER HOLE IN WALL LOCATE PIPE SUPPORT CLAMP WITHIN 1"[25MM] FROM SPRINKLER FITTING'S INLET IIIIIII= STUD A 048FG010 *SEE LISTED DESIGN CRITERIA TABLE FOR FLOW RATE AND PRESSURE BASED ON DEFLECTOR TO CEILING DISTANCE. DEFLECTOR IS 3/8"[9.5MM] ABOVE CENTERLINE OF SPRINKLER. Fig.2 Front View Attachment Method: Fig. 3: 1. Securely support pipe from adjacent stud. 2. Pipe support clamp shall be located within 1" [25 mm] of sprinkler fitting's inlet lip. 3. The center of the sprinkler fitting shall be located at a horizontal distance of 13/" [35 mm] or more from the stud (Fig. 3). 4. The sprinkler fitting shall be installed so that the rear of the sprinkler is 2" +/- 1/16" from the finished surface of the wall.Verifywall assembly dimensions prior to installation to ensure that the cover plate attaches to the sprinkler and seats against the finished wall surface (Fig. 1). ELBOW — MINIMUM 1-3/8"[35MM] 3-1/8" m,— [79MM] STUD— /.viU////.////.%////////////////1� WALL FINISH MATERIAL DIMENSIONS ON THIS FIGURE ARE BASED ROOM ON A SPEARS TORQUESAFETM 3/4"X 1/2"90° CENTERLINE SPRINKLER HEAD ELBOW(4207-101). 098FC03B DIMENSIONS MUST BE ADJUSTED IF OTHER FITTINGS ARE USED. Fig.3 3. 5. Maintenance Cover Plate Finishesco Model RFS42 Concealed Sprinklers should be inspected Standard Finish and maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water,ammonia or any otherclean- White ing fluids. Remove dust by using a soft brush or gentle Special Application Finishes vacuuming. Replace any sprinkler or cover plate assem- Flat White Paint bly, which has been painted (other than factory applied) or Off White Paint damaged in any way. A stock of spare sprinklers should Black Paint be maintained to allow quick replacement of damaged or Custom Color Paint operated sprinklers. Prior to installation, sprinklers should Bright Brass be maintained in their original cartons and packaging until Bronze Chr used to minimizethe potential for damage to sprinklers that Satome Satin Chrome would cause improper operation or non-operation. Once Black Plating operated automatic sprinklers and cover plates cannot be reassembled and reused.New sprinklers of the same size, ")Other colors and finishes are available. Consult factory for details. type and temperature rating must be installed. A cabinet of Note:Paint or any other coatings applied over the factory replacement sprinklers should be provided forthis purpose. finish will void all approvalsand warranties. Model RFS42 Residential FlatCoverConcealed Horizontal Sidewall SprinklerSpecification Ordering Information Sprinklers shall be a UL listed as residential flat cover Specify: concealed horizontal sprinkler with RFS42 deflector and 1. Model RFS42Residential Sidewall adjustable cover plate for light hazard, interior, non- 2. Cover Plate Type:Solid or Perforated corrosive applications. Sprinklers to be of bronze frame 3. Cover Plate Finish construction with brass cover plate and copper alloy retainerflangeassembly.Watersealassemblyshallconsist Installation Wrench of a Teflon*coated Belleville spring washer and machined Model G6 Sprinkler Wrench brass cup containing no plastic parts.Method of attaching the cover plate to the sprinkler cup shall be a Push-on Installation Aid and Pull-off design allowing a 1/8" cover plate adjustment. A protective plastic cap is included for use during instal Sprinklersshall have a nominal K-factor of 4.2(60 metric), and 1/2" NPT thread. Sprinkler temperature rating shall lation. be 165°F (74°C)with a cover plate temperature rating of 135°F (57°C). Sprinklers shall be capable of a maximum coverage area of 16 ft. x 20 ft. (4.9 m x 6.1 m), with a minimum lateral spacing of 8 ft. (2.4 m). Rated working pressure shall be 175 psi (12,0 bar). A plastic protective cap shall be provided and factory installed onto the sprinkler cup to protectthe sprinklerfrom damage, which could occur during construction before the cover plate is installed. Cover plate type: [Solid] [Perforated].Cover plate finish: [White] [Custom Color—specify]. Residential Coverage Concealed horizontal sidewall sprinklers shall be Reliable Model RFS42.SIN RA4835(Bulletin 048). *DuPont Registered Trademark Theequipmentpresented in this bulletinis to be installed in accordance withthe latestpublished Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or othersimilarorganizations and alsowiththe provisions of governmental codes or ordinances wheneverapplicable. Products manufactured and distributed by Reliable have been protecting lifeand propertyforover90 years,and areinstalled and serviced bythe most highly qualified and reputable sprinklercontractors located throughout the United States,Canada and foreign countries. Manufactured b Reliable Automatic SprinklerCo.,Inc. :Si Recycled Reliabi ® (800)(800)431-15888486051 Sales Offices 1r Paper Sales Fax (914)829 2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.04/15 P/N 9999970457 NIBCO www.nibco.com AHEAD OF THE FLOW® Revision 3/29/04 e s. All of the advantages found in copper as a metal have been capitalized to the utmost in the manufacture of NIBCO Fittings.Because of the accuracy of construction and design, copper plumbing is more efficient and less expensive. NIBCO manufactures nine general types of fittings:Wrot Pressure;Cast Pressure;WrotDrainage; Cast Drainage; Flanges; Flared Tube;Threaded Bronze;Insert Fittings for PEX;Barbed Insert Fittings for Polybutylene.Each has its particular place and use and each offers its own advantages when used for the proper service requirement. ALLOY AND FINISH—NIBCO Fittings are made from highest quality raw materials available—Cast Fittings are made from Copper Alloy C84400 which consists of 81% Copper,7% Lead,3%Tin,and 9%Zinc per ASTM Specification B584.Wrot Copper Fittings are made from commercially pure copper mill products per ASTM Specifications B75 Alloy C12200. NIBCO fittings are produced to meet requirements of applicable standards wherever practicable. NIBCO brand wrot and cast fittings are manufactured in the U.S.A.and Mexico.The manufacturing plants at Stuarts Draft,VA, Nacogdoches, TX and Reynosa, Mexico are registeredto ISO 9002 quality standards. Following is suggested phrasing to be incorporated in your specifications or bills of material for Copper Tube Fittings. R WROT SOLDER JOINT FITTINGS—"Wrot Solder Joint Fittings shall be produced to one of the following specifications: 1. Material and workmanship shall be in accordance with ASME/ANSIB16.22; Wrought Copper and Copper Alloy Solder Joint Pressure Fittings." 2. The dimensional, material and workmanship shall dimensions of Federal Specifications WW-F-406 or meet the requirements of MSS SP-104; Wrought ASME Std. B16.24. Copper Solder Joint Pressure Fittings." CLASS 125 —Material,workmanship and 3. The dimensional, material and workmanship of dimensions of flanges shall be in accordance with 5"-12" copper fittings shall meet the requirements MSS SP-106. of MSS SP-109 "Welded Fabricated Copper Solder CAST BRONZETHREADEDFITTINGS— Joint PressureFittings." "Cast Bronze Threaded Fittings shall be in accordance 4. Certifiedto ANSI/NSF61. with ANSI/ASMEB16.15." CAST COPPER ALLOY SOLDER JOINT FITTINGS POLYBUTYLENE COPPER INSERT TYPEVALVES AND —"Cast Copper Alloy Solder Joint Fittings shall be in FITTINGS—"Wrot Copper Insert Fittings shall be accordance with ANSI Std. B16.18." manufactured per the following specifications: WROT DRAINAGE FITTINGS—"Wrot Drainage MSS SP 103 or ASTM F1380." Fittings shall be in accordance with ASME/ANSI Std. NIBCO Copper Tube Fittings are all produced to above B16.29." Standards.Tosimplify,writeyourspecificationsto CAST COPPERALLOYSOLDERJOINT DRAINAGE read: "Copper Tube Fittings to be in accordance with FITTINGS—"Cast Copper Alloy Solder Joint Drainage specifications as outlined in NIBCO Catalog c cf 0602." Fittings shall be in accordance with ASME Std. WROTCOPPERMEDICALMEDICALGAS SYSTEM B16.23." COMPONENTS—Wrot copper fittings that are to be CAST COPPER ALLOY FLAREDTUBEFITTINGS—"Cast installed in medical gas applications shall be prepared in accordance with NFPA99, Health Care Facilities Copper Alloy Flared Tube Fittings shall be in accor- dance with ASME/ANSI Std. B16.26. Gas and Vacuum Systems and the Compressed Gas Association, Pamphlet G4.1. Packaging shall CAST COPPER ALLOY FLANGES AND FLANGED be adequately protectiveand include labeling that FITTINGS— identifies the preparerand states that the product CLASS 150—Cast Copper Alloy Flanges and has been cleaned and bagged for oxygen or med gas service. Flanged Fittings shall meet the requirements of MSS SP-106 and/or the workmanship and For technical information and dimensions ref erto the engineering section contained in this catalog. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURYST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 4 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONALOFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com NI BCO www.nibco.com AHEAD OF THE FLOW° Revision 5/12/02 Copper Waterlubecontinued COPPER TUBE -TYPES, STANDARDS, APPLICATIONS, TEMPERS AND LENGTHS Commercially AvailableLengths TubeType Color Code Standard Application Nominal or Standard Sizes Drawn Annealed TypeK Green ASTM B 88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 8-inch 20 ft.(6.1m) 20 ft.(6.1m) Fire Protection 10-inch 18 ft.(5.5m) 18 ft.(5.5m) Solar 12-inch 12 ft.(3.7m) 12 ft.(3.7m) Fuel/Fuel Oil Coils: 1/4-inch to 1-inch — 60 ft.(18.3m) HVAC — 100 ft.(30.5m) Snow Melting 11/4-inch&11/2-inch — 60 ft.(18.3m) 2-inch — 40ft.(12.2m) 45ft.(13.7m) TypeL Blue ASTM B88 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 10-inch 20 ft.(6.1m) 20 ft.(6.1m) Fire Protection 12-inch 18 ft.(5.5m) 18 ft.(5.5m) Solar Fuel/Fuel Oil Natural Gas Coils: 1/4-inch to 1-inch — 60 ft.(18.3m) Liquified Petroleum(LP)Gas — 100 ft.(30.5m) HVAC 11/4-inch&11/2-inch — 60 ft.(18.3m) Snow Melting 2-inch — 40 ft.(12.2m) 45ft.(13.7m) X TypeM Red ASTM1388 Domestic Water Service Distribution Straight Lengths: 1/4-inch to 12-inch 20 ft.(6.1m) N/A Fire Protection Solar Fuel/Fuel Oil HVAC Snow Melting DWV Yellow ASTM B 306 Drain Straight Lengths: 11/4-inch to 8-inch 20 ft.(6.1m) N/A Waste Vent HVAC Solar ACR Blue ASTM B 280 Air Conditioning Straight Lengths: 1/4-inch to 41/e-inch 20 ft.(6.1m) 20ft.(6.1m)1 Refrigeration Natural Gas Coils: 1/e-inch to 15/2-inch — 50 ft.(15.3m)1 Liquified Petroleum(LP)Gas OXY TypeK ASTM B 819 Medical Gas Straight Lengths: 1/4-inch to 8-inch 20 ft.(6.1m) N/A MED Green OXY/MED OXY/ACR TypeL ACR/MED Blue TypeG Yellow ASTM B 837 Natural Gas Straight Lengths: 3/8-inch to 11/8-inch 12 ft.(3.7m) 12 ft.(3.7m)1 Liquified Petroleum(LP)Gas 20 ft.(6.1m) 20ft.(6.1m)1 Coils: 3/e-inch to 7/e-inch — 60 ft.(18.3m)1 100 ft.(30.5m)1 1 Availableas special order only. U.S.customaryunits in this documentarethe standard;the metricunitsare providedfor reference only.The valuesstated in each systemare not exact equivalents. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURYST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX:1.888.234.0557•INTERNATIONALOFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 81 www.nibco.com SUSPENSION CLAM PFO R CTS PIPING ))557SERIES EZGlideTM ITEM#SUBMITTED JOB NAME SPECIFICATION LOCATION Sioux Chief 557 series suspension clamps are to be used where ENGINEER necessary to secure or suspend CTS piping in residential or commercial applications.Tube clamp has a split, ribbed design to allow for use CONTRACTOR after piping is run and to allow pipe to expand and contract. Clamps are PO# TAG compatible with CTS copper, PEXor CPVC tube. Clamps shall be IAPMO certified. INSTALLATION Spread each side of the clamp and position clamp around the tube. Use approved nail or screw in both of the provided holes to secure to stud member or structure. MATERIALS 557-2 557F4 F *Standard(ivory):high impact polypropylene E Plenum-safe(orange): po lyvinylidenefluo ride meets ASTM E 8425/50 with UL 94 V-0 rating 0 O — WORKING TEMPERATURE Standard(ivory):140°F continuous;impact resistantto 0°F Plenum-safe(orange): -10°F- 140°F A 1 SAFE WORKING LOAD D� Standard(ivory):25 lbs. Plenum-safe(orange): 25 lbs. 1/2" and 3/4" models E DIMENSIONS O O 557-2 557-3 557-4 557-5 557-6 557-7 I A:Tube size CTS 1/2" 3/4" 1" 11/4" 11/2" 2" B B:Screw hole to 0.938" 1.108" 1.013" 1.188" 1.363" 1.663" tube center A C:Overall height 1.703" 1.998" 2.019" 2.332" 2.639" 3.219" D:Overall depth 0.625" 0.675" 0.825" 0.975" 1.025" 1.125" E: Mounting hole 1.206" 1.409" 1.421" 1.827" 1.827" 2.436" D center-lines 1"-2" models F: Mounting tab 0.12" 0.12" 0.12" 0.15" 0.15" 0.15" wall thickness 11P® G: Hole diameter 0.188" 0.188" 0.188" 0.188" 0.188" 0.188" Made in USA Create Item Number 557-A B e.g.557F3:Plenum-safe 3/4" CTS suspension clamp MATERIAL A SIZE B ❑ —=High-impact polypropylene ❑ 2=1/2"CTS ❑ F =Polyvinylidene fluoride ❑ 3 =3/4"CTS ❑ 4 =1"CTS ❑ 5 =11/4"CTS ❑ 6 =11/2"CTS ❑ 7 =2" CTS Sioux Chief Sioux Chief Manufacturing Company I P:1.800.821.3944 I F: 1.800.758.5950 I www.siouxchief.com 10-16 TUBE CLAMPFORCTS PIPING II 559SERIES ITEM#SUBMITTED JOB NAME SPECIFICATION LOCATION Sioux Chief 559series tube clamps are to be used where necessary to ENGINEER secure CTS piping in residentialor commercial applications.Tube clamp has a split,ribbed design to allow foruse after pipingis run and to allow CONTRACTOR pipe to expand and contract.Clamps shall be compatiblewith CTS copper, Po# TAG PEX or CPVC tube.Clamps shall be IAPMO certified. INSTALLATION Spread each side of the clamp and position clamp around the tube. Use approved nail or screw in both of the provided holes to secure clamp to stud member or structure. MATERIALS Standard(ivory):high impact polypropylene ' Plenum-safe(orange): po lyvinylidenefluo ride meets ASTM E84 25/50 with UL 94 V-0 rating 559-2 SAFE WORKING TEMPERATURES *Standard(ivory):140°F(continuous); impact resistant to 0°F Plenum-safe(orange): -10°Fto 140°F SAFE WORKING LOAD Standard(ivory):25 lbs Plenum-safe(orange): 15 lbs 559F6 DIMENSIONS D 5592 5593 559_4 559_5 559_6 5597 A:Tube size (CTS) 1/z" 3/4" 1" 11/4' 11/2" 2" B:Overall height 1.021" 1.275" 1.535" 1.785" 2.034" 2.562" clir A B C: Overall length 2.415" 2.617" 2.821" 3.227" 3.421" 3.836" D:Overall depth 0.624" 0.675" 0.825" 0.975" 1.025" 1.125" F I J [ E: Mounting hole 1.624" 1.827" 2.233" 2.639" 2.843" 3.248" c • center-lines F: Mounting tab .603" .603" 0.12" 0.15" 0.15" 0.15" wall thickness G: Hole diameter 0.188" 0.188" 0.188" 0.188" 0.188" 0.188" E ® Made in USA Create Item Number 559A B e.g.559F3:Plenum-safe 3A"CTS tube clamp MATERIAL A SIZE B ❑ -=High-impact polypropylene ❑ 2=1/2"CTS ❑ F =Polyvinylidene fluoride ❑ 3 =3A"CTS ❑ 4 =1"CTS ❑ 5 =11/4"CTS ❑ 6 =11/2"CTS ❑ 7 =2" CTS Sioux Chief Sioux Chief Manufacturing Company I P:1.800.821.3944 I F: 1.800.758.5950 I www.siouxchief.com 11-16 101 Loop Hanger for Copper Tube 0 • Recommended for the suspension of stationary non-insulated coppertube lines • Conforms with Federal Specification WW-H-171 (Type10J, Manufacturers Standardization Society(MSS)SP-58(Type10) RS L- B A OD Material:Steel Finish:Copper Electroplated,Electrogalvanized IOuter Diameter Rod Size Static Load PartNumber Pipe Size A B C OD RS F 1010050CP 1/2" 5/8" 3/8" 3 3/16" 1 5/8" 1 9/16" 180 lb 1010075CP 3/4" 7/8" 3/8" 3 1/8" 1 3/8" 1 3/16" 180 lb 1010100CP 1" 11/8" 3/8" 31/8" 15/16" 1" 1801b 1010125CP 1 1/4" 1 3/8" 3/8" 3 3/16" 1 1/4" 13/16" 180 lb 1010150CP 1 1/2" 1 5/8" 3/8" 3 5/8" 1 9/16" 15/16" 180 lb 1010200CP 2" 21/8" 3/8" 313/16" 17/16" 5/8" 1801b 1010250CP 2 1/2" 2 5/8" 3/8" 4 7/16" 1 11/16" 9/16" 200 lb 1010300CP 3" 31/8" 1/2" 511/16" 21/2" 15/16" 2501b 1010350CP 3 1/2" 3 5/8" 1/2" 6 7/16" 3" 1 9/16" 300 lb 1010400CP 4" 4 1/8" 1/2" 7 1/8" 3 7/16" 1 3/4" 360 lb 1010500CP 5" 5 1/8" 5/8" 9 1/4" 4 11/16" 2 5/16" 480 lb 1010600CP 6" 6 1/8" 3/4" 11 3/16" 5 3/4" 2 15/16" 630 lb WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials.Instruction sheets are available at erico.pentair.comand from your Pentair customer servicerepresentative.Improperinstallation,misuse,misapplication or other failure to completelyfollow Pentair's instructions and warnings may cause product malfunction,property damage,serious bodily injury and death and/or void your warranty. ©2017 Pentair All rights reserved Pentair,CADDY,CADWELD,CRITEC,ERICO,ERIFLEX,ERITECHand LENTONare owned by Pentair or its global affiliates. Another trademarks are the property of their respectiveowners.Pentair reservesthe right to change specifications without priornotice. ,S' 0 PENTAIR CADDY SAMMYS® HORIZONTALMOUNT SIDEWINDERS° f orW ood 7falls HORIZONTALLY into the side of woodstructures easilyand quickly! Not less than 2"nominal width Product Features 0 " (1-1/2°)up to 3-1/2"pipe;not less than 3"(2-1/2")nominal width 4"&5"pipe •No pr e-dr illing equir ed. FloorJoist •Quick to install using the Sammy Minimum 2-1/2"fr onbottomfor br and fines.Minimum 3"from Nut Dr iverwith an 18V cor dless bottomformain lines.Eoception:This drill/driver. ? r equir emenkhall not applyto 2"or i thickernailing str ips estingon top of steel beams. •Saves time fr omtr aditional methods. 1 '1" •Reduces installation cost. Q r •Made in the U.S.A. 0 IL ' MP- Ildit . ,.. I !- _ 0 CorrlpositelTruss IX" Consult lr ussnanufactur erfor ' r ecommendednstallation point. EL i "r a-dr illingnay be r equir edorModel SWG 25-380(tools available on pg 10) CI Rod Part Screw Ultimate UL Test Box Case Approvals Model Size Number Descriptions Pullout(Ibs) Load(Ibs) Qty Qty 1/4" 8018957 SWG 100 1/4 x l" 622 (Fir) 25 125 _ I+i 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 125 125 = 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 , 3/8" 8021957 SWG20 114x2" 1725 (Fir) 1050 25 3/8" 8073925 SWG 20-SS 1/4 x 2" 1725 (Fir) 850 25 125 #14 SW Red ®• 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 Nut Driver ' 3/8" 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 Par t#8114910— VERTICAL HORIZONTAL • 1.Insertthe appropriate nut driver into a 3/8"or 1/2"portable drill. 1.Inserttheappropriate nutdriver into a 3/8"or 1/2"portable drill. 2.InserttheSAMMYS into the#14(black)nut driver(p/n 8113910).Drill 2.InserttheSAMMYS into the#14SW(red)nut driver(p/n 8114910).With drill shouldbe in a vertical position. unitina horizontal position and at a rightangle to the structural member, begin installation. 3.Pushthe face of the nut drivertighttothemember.When the nut driver spins freely on the SAMMYS,stopdrill and remove. 3.When thenut driver spins free on the SAMMYS,stopt he drill and remove. 4.The SAMMYS isnowreadytoreceive 1/4",3/8'; 1/2"ormetric allthreadrod,boltstock.(The 1/2"requires the#14SWrednutdriver) 4.The unitisnowreadytoreceive 1/4",3/8"ormetricallthreadrodor boltstock. Note:When installing DSTR,follow the above instructions, then add retainer nut and torque to 20 footlbs.formaximum Note:When installing SWDR,follow the above instructions,then add retainer nut pulloutin puffin steel. and torque t ,, o 20 footlbs.formaximum pull outin purlin steel. 'iis 1.,,, ll sj_. 1 .,„, , , _ )7 !tel 7 , <' lIII.:A.1 SPECIAL NUT DRIVER SYSTEM:The nut driver sver edesigned with a unique spin-offfeature which pr ovidesa fast and safe installation each time.When the face of the dr ivercomes into contactwith the mater iayou ar einstalling into,continue dr illing until nut dr iverspins fr eelnstallationis then complete.Warranty r equir edhe use of the appropriate nut dr iverforinstallations. 5 Tofind a distributornear you,call 800-BUILDEX L ILI - MODEL- CRD- Direct Acting CLA-VALTM Pressure Reducing Valve • Meets Requirements of "Reduction of Lead in p,,1/4746...,_„,,,,, DCF 5° o Drinking Water Act” WaterQualty 5 • Sizes: 3/4"• 1" • 1-1/4" • 1-1/2" • 2" • 2-1/2" %,'4.0.,5, • Operates in Any Position • Easy Installation Cla-Val products comply with the • Stainless Steel Trim Standard National Lead Free Mandate • Gauge Connections Standard "Reduction of Lead in -_ Drinking Water Act" • All Bronze Body and Cover .0,0 • EPDM Disc and Diaphragm The Cla-Val Model CRD-L Pressure Reducing Valve automatically reduces a higher inlet pressure to a steady lower downstream pressure with our unique design. This valve is an accurate regulator capable of holding downstream pressure to a predetermined amount, regardless of upstream pressurefluctuations. Periodic maintenance consist of regular internal cleaning that is accessed by removing bottom plug. TypicalApplications Flow Cla-Val m. 1f-' 90 Series Pressure High rise buildings use CRD-L Pressure Reducing High ���� hI Reducing Valve Pressure ,m , Valves in various water systems (potable water, boiler U feed air conditioning, etc.)to control pressure fluctuations Y = ° ,,,, , between floors. �t00 ©•,'-P' Isolation �'-►' Valve 0 0 `e5) CO % Industrial plants use CRD-L Pressure Reducing Valves between a high pressure supply system and equipment / „-- I1 requiring lower pressure. Typically CRD-L Pressure Reducing Valves are used at supply connections for water Cla Val CRD-L m heaters,boiler feed water or other processwater systems. Lowiik Pressure Municipal water systems use CRD-L Pressure Flow Reducing Valves at service connections in a high Cla-Val CRD-L pressure distribution zone.Depending on flow High I • / requirements,CRD-L'smay be installed in parallel. Pressure 44 One CRD-L provides desired outlet pressure while the second CRD-L handles low flow conditions. If necessary, Is ;4 additional CRD-L's can be added for more flow capacity. The CRD-L is also ideal for a low flow bypass around a Low larger Cla-Va190 Series Pressure Reducing Valve. `, Pressure Isolation rl % ValveANS lilk < wig,. 1 Cla-Val CRD-L Valve Operation ft" i -_,_ L ' -y ' J 11.-- ■llelif j j '- Fa ildesiiii 1111 311t 1 Flow Condition No Flow Condition When flow begins, the pressure on the underside of the When there is no flow,the dow nstreampressure increases and diaphragm will be lower than the set-point of the spring acts against the under side of the diaphragm, pulling the valve causing the diaphragm to move the valve seat away from seat up against the valve seal to close the valve. the valve seal allowing flow to occur. As the flow increases downstream,the pressure acting on the spring pushes the diaphragm and the valve seat awayfrom the valve seal to regulate outlet pressure to desired value. Reduced Pressure Falloff Sizing Unlike pilot controlled pressure reducing valves, direct Step One acting valves are subject to "reduced pressure falloff" Determine the follow ingfrom the application: (RPF). Reduced pressure falloff is the decrease in dow nstream regulated pressure that occurs w hen the flow 1. Inlet pressure and desired outlet pressure increases.When the demand for flow increases,the valve 2. Maximum and minimum flow rate must open wider and wider to permit the flow. The only 3. Allow ablereduced pressure falloff or waythe valve can open is for the spring force to be greater maximum velocity based on acceptablenoise level than the hydraulic force under the diaphragm (the force trying to close the valve). The downstream pressure Step Two therefore,must "fall off"or decrease before the spring can Determine the pressure differential across the valve by open the valve. All spring actuated direct acting valves subtracting the desired outlet pressure from the inlet pressure.If have similar operating characteristics. there w ill be any fluctuations in the inlet pressure,calculate both high and low differentials.At all times the differential must be at Noise and Velocity Guidelines least 14.5 psi. When the differential is greater than 100 psi, use twovalves in series. Noise in waterpiping systems can sometimes be attributed to high velocities of water through the valve seat. In Step Three general, as the water velocity increases, the noise Determine the valve size by using the Valve Capacity Charts on produced by the installation w ill increase. the next page. Start by referring to the valve capacity chart for Where noise levels are important, such as residences, the system's maximum flow rate. Locate the value for the hospitals, or schools, pipeline velocities should be in the maximum allowable reduced pressure falloff for your range of 5 to 10 fps. The chart below shows velocity and application. Select the valve size with a RPF value that is less the corresponding reduced pressure falloff. If these values than the maximum RPF. for falloff are not exceeded, the CRDL will produce the If flow demand fluctuates beyond the capacity of one valve,use least amount of noise. two or more Model CRDL'sin parallel.Size one valve to handle the low flow,and the other valve(s)to handle the higher flows. Set the low flow valve to approximately 3-4 psi higher than the other valve(s). Velocity Velocity Delta from Set Point Pressure Falloff psi Guide C hart Set Point,fps 3/4"and 1" 1-1/4" and 1-1/2" 2" 2-1/2" 5.0 6.0 3.5 6.0 8.5 7.5 9.5 6.5 9.5 12.0 10.0 12.5 8.5 12.5 17.0 Valve Capacity Charts System Flow Rate -GPM Sys 112" to 1 114 0 10 20 30 40 50 SO 70 F 0 9- 2 5 - To u_ \\\NN '-......, 10 112 zi no 15NN. mi c 20 I - 1 /2" 3/4" 1 " 1 1/4" System Few Rate- G PM Sizes 1 1P2' to 2 11/2" 0 25 50 75 100 125 150 175 200 0 i } r : : 15 1 s s s I { -I 1/2" 1/2" Adjustment Range Spring Description Spring Range PSI/Turn 'hi Green 15-65 PSI 3.5 PSI/Turn Dark Green 25-100 PSI 6 PSI/Turn Blue 80-150 PSI 10 PSI/Turn Specifications Temperature Range Materials Water: to 140°F (70°C) Max Body and Cover: Low Lead Bronze CuZn21Si3P Diaphragm: EPDM Pressure Ratings Maximum Inlet Pressure:400 psi (25 Bar) Disc: EPDM Maximum Outlet Pressure:150 psi (10 Bar) Minimum Differential Pressure:14.5 psi Dimensions (Inches) Dimensions (mm) Size A B C D E Weight Size A B C D E Weight (lbs.) (kgs.) 3/4" 5.60 6.06 2.56 3.12 8.62 4.0 20 143 154 66 80 219 1.8 1" 6.68 6.06 2.56 3.12 8.62 4.0 25 170 154 66 80 219 2.3 1-1/4" 8.40 7.84 2.75 4.13 10.59 7.5 32 214 199 70 105 269 3.4 1-1/2" 9.56 7.84 2.75 4.13 10.59 8.5 40 243 199 70 105 269 3.9 2" 11.38 6.77 3.86 4.83 10.63 15.1 50 289 172 98 123 270 6.85 2-1/2" 12.20 6.77 3.86 4.38 10.63 17.8 65 310 172 98 123 270 8.07 Gauge Connections D ► 3/4"through 1-1/2" has A A 1/8" FNPT I MN BIl. 0 Y� i r.- . -15,!._ CQLIp I I • ■ ice:- -:moi U � '�1��� _� ,\Ili° ) � � , C `- %_. ill A Ii1ii1 V When Ordering, Please Specify 1.Catalog No. CRD-L 2. Size 3. Adjustment Range 4. Optional Lock ingCap ® CLA-VAL Represented By: VV.; 1701 PlAve.Costa Ma, CA Phone:acentia 949-722-4800•Faxes:949-548-5441 92627-4475 LIN, CLA-VAL CANADA CLA-VAL EUROPE 4687 Christie Drive Chemin des Mesanges 1 Beamsville,Ontario CH-1032 Romanel/ Lausann 463-4963 C LA VALM -643-15-55 Fax: L905 563-4040 Fax: 4Phone: Switzerland 41-21-643-15-50 E-CR D-L(R-11/2015) cCOPVRIGHTCLA-VAL 2015 hooted in USA Specifications subject to change without notice. www.cla-val.com ES-A-LF2000B Series LF2000B AMES Double Check Valve Assemblies FIRE&WATERWORKS Sizes: 1/2" — 2" (15 —60mm) LEAD FREE Features S. `}— • • Ease of maintenance with only one cover `' • Top entry b*-,Ari • Replaceable seats and seat discs 11 • Modular construction 6. • Compact design 3/4" LF2000B • '/z" -2" (15-50mm)Lead Free* (20mm) cast silicon copperalloy body construction SeriesLF2000B Double Check ValveAssemblies shall be installed at referenced cross- • Top mounted ball valve test cocks connections to prevent the backflow of polluted water into the potable water supply.Only • Low pressure drop those cross-comections identified by local inspection authorities as non-health hazard • No special tools required shall be allowed the use of an app roveddouble check valve assembly. • '/z" -1" (15-25 mm) have Check with local authorityhaving jurisdiction regarding vertical orientation,frequency of tee handles testing or other installation requirements. These valves meet the requirements of ASSE Std. 1015 and AWWA Std.C510 and are approved by the Foundation for Cross-Comection Control and Hydraulic Research at the Available Models University of Southern California.The LF2000B features Lead Free*construction to com- ply with Lead Free*installation requirements. Suffix: B- Quarter turn ball valves Specifications LBV- less ball valves A Double Check ValveAssembly shall be installed at each noted location.The Double Check ValveAssemblies shall be constructed using Lead Free*materials. Lead Free* valves shall comply with state codes and standards, where applicable, requiring reduced Pressure — Tem erature lead content.The assembly shall consist of two positiveseating check modules with p captured springs and rubber seat discs.The check module seats and seat discs shall be Temperature Range:33°F-140°F replaceable.Service of all internalcomponents shall be through a single access cover (0.5°C-60°C) secured with stainless steel bolts.The assembly shall also include two resilient seated iso- Maximum Working Pressure: 175psi lation valves and four top mounted, resilient seated test cocks.The assembly shall meet (12.06 bar) the requirements of ASSE Std. 1015 and AWWA Std.C510. Approvedbythe Foundation forCross-Comection Control and Hydraulic Research at the University of Southern Cali- fomia.Assembly shall be an Ames CompanySeriesLF2000B. Standards Approvals AWWA Std. C510, IAPMO PS31O c�pSSIFj�o *The wetted surface of this product ® c us �p C ® US contacted by consumable water 1015 B64.5 3/4"-2" contains less than 0.25%of lead by (LBV Models Only) weight. Approved bythe Foundation forCross-Connection Control and HydraUiic Research at the University of Southern California. LBV models not listed. Horizontal and vertical"flow up"approval on all sizes. Job Name Contractor Job Location Approval Engineer Contractor's P.O.No. Approval Representative Ames productspecifications in U.S.customary units and metric are appropmate and are provided for reference only.For precise measurements,pleasecontactAmes Technical Service.Ames reserves the right to change or modify prodict design,construct ion,spedfications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Dimensions - Weights Nikk A .%. ...... - 7 = ., ' ., MC B � --���� ® -�- 0 j=•I�� ---m.I■- \ 1--.i• 1 1P" /F H I ---- LF20008 G SIZE(DN) DIMENSIONS WEIGHT A B C F G H I in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. /2 15 10 254 4% 117 21/46 62 5 127 3% 85 25/16 59 2'/,6 52 4.5 2 3/4 20 111/2 282 4 102 31/2 79 63/s 157 31/46 87 21/s 54 15/6 33 5 2.3 1 25 131/4 337 51/2 130 4 102 712 191 3% 85 111A6 43 111/46 43 12 5.4 114 32 16% 416 5 127 35A6 84 91/ 241 5 127 3 76 2 50 15 6.8 11 40 16% 425 4% 124 31/2 89 9% 248 513/6 148 31/s 79 211/6 68 15.86 7.2 2 50 191/2 495 61/4 159 4 102 133/2 340 612 156 37/6 87 211/6 68 25.75 11.7 Strainer sold separately Capacities kPa psi A 11/4"(32mm) As compiled fromdocumented FoundationforCross-Connection Control 96 14 and Hydraulic Research at the University of SouthernCalifornia lab tests. y 83 12 *Typical maximum system flow rate(7.5feet/sec.,2.3 meters/sec.) J 69 10 "(15mm) d 55 8 '/2 kPa psi m 41 6 y 83 12 A d 28 4 r- C 69 10 " 14 2 y 55 8a 0 0 41 6 co 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm to• 14 2 AP 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 0. 0 0 5 7.5 10 15 fps 0 2 4 6 8 10 12 gpm 1.5 2.3 3.0 4.6 mps AP 0 7.6 15.2 22.8 30.4 38 45.6 1pm Flow Rate 5 7.5 10 fps 1.5 2.3 3.0 mps kPa psi 11/2"(40mm) Flow Rate 83 12 kPa psiA 3/q"(20mm) in 69 10 C152 22 D 55 8 to J J 124 18 i 41 6 28 4 3 96 14 m 14 2 O 69 10 a 0 0 a) pp0 10 20 30 40 50 60 70 80 90 100 110 120 gpm a 41 6 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 14 2 �� 5 7.5 10 15 fps 0 5 10 15 20 25 30 35 40 45 50 gpm 1.5 2.3 3.0 4.6 mps AP 0 19 38 57 76 95 114 133 152 171 190 Ipm Flow Rate 7.5 15 fps 2.3 4.6 mps kPa psi 0 2" Flow Rate N 83 12 kPa psi "(25mm) w 110 16 J 69 10 N n 1 55 8 J 83 12 3 8 41 6 2 69 10 wH 28 4 y• 41 6 14 2 N 28 4 Il 0 0 0- 14 2 - 0 25 50 75 100 125 150 175 200 gpm AP 0 95 190 285 380 475 570 665 760 Ipm 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm 5 7.5 10 15 fps AP 0 19 38 57 76 95 114 133 152 171 190 209 228 1pm 1.5 2.3 3.0 4.6 mps 5 7.5 10 15 fps Flow Rate 1.5 2.3 3.0 4.6 mps Flow Rate e,UILD% et A M E S 9001-2008 FIRE&WATERWORKS www.amesfirewater.com beMeEP CERTIFIED A Watts Water Technologies Company USA: Backf low- Tel:(916)928-0123 •Fax:(916)928-9333 Control Valves- Tel:(713)943-0688•Fax:(713)944-9445 Canada: Tel:(905)332-4090•Fax:(905)332-7068 ES-A-LF2000B 1322 ©2013 Ames Fire&Waterworks FOR SMALL PIPE VSR-SF PPDffEJ . VANE TYPE WATERFLOW The Symbol of Protection ALARMSWITCH WITH RETARD UL,ULC,CSFM Listedand NYMEAAccepted,CE Marked Service Pressure: Up to250 PSI (17,2 BAR) Minimum Flow RateforAlarm: 8-10 GPM(30-38 Lpm) Maximum Surge: 18 FPS(10 m/s) Enclosure:Die-cast,red enamel finish �r Cover held in place wit ht amperresistantscrews Contact Ratings: Two set sof SPDT(Form C) 15.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC �►'; Conduit Entrances: Two knockouts provided for 1/2" conduit. • Usage: Listed plast ic,copper and schedule 40 iron pipe. Fits pipe sizes- 1" (25mm), 1 1/4" (32mm), 1 1/2" (38mm) and 2" (50mm) ® Note:12 paddles are furnished with each unit,one for • each pipe size of threaded and sweat TEE,one for 1" (25mm) CPVC, one for 1" (25mm) CPVC(Central), one for 1 1/2" (38mm) polybutyleneand one for 1 1/2" (38mm) threaded (Japan). (CTS-Copper tubing size) Environmental Specifications: • Suitable for indoor or outdooruse withfactory installed gasket and die-cast housing. • NEMA 4/IP55 rat edenclosure-use wit happropriate conduit fitting. •Temperature range:40° F to 120° F,4,5° C to 49° C) Caution: This device is not int ended for applicat ionsin explosive environments. Service Use: StockNo.1113000 Automat icSprinkler NFPA-13 U.S. Pat.No. 3921989, Canadian Pat.No. 1009680 One or t wofamily dwelling NFPA-13D Residentialoccupancyup tofourstories NFPA-13R Ot herPatentSPending National Fire Alarm Code NFPA-72 Optional:CoverTamper SwitchKit,StockNo. 0090018 The Model VSR-SF is a vane t ypewat erflowswit chforuse on wet wat erf low. sprinkler systems that use 1" (25mm), 1 1/4" (32mm), 1 1/2" The vane must not rubtheinside of theTEE or bind in any way. (38mm) or 2" (50mm) pipe size. The unit may also be used as The stem should move freely when operated by hand. a sectional waterflow detect or on large systems. The device can also be used in copper or plastic pipe inst alla- The unit contains two single pole double throw snap action tionswiththe proper adapters so t hat t he specified TEE fitting switches and an adjustable, instantly recycling pneumatic re- may be installed on the pipe run. t ard.The swit chesare act uat edwhen a flow of 8-10 gallons per minute(30-38 Lpm)or more occurs downst ream of t he device. INSPECTION AND TESTING: Checktheoperationoftheunitby The flow condition must exist for a period of time necessary to opening theinspector'stestvalve at theend of thesprinklerline overcome the selected retard period. orthedrain and testconnection,ifan inspector'stestvalveis not provided. INSTALLATION: These devices may be mounted in horizontal or verticalpipe. On horizontalpipe theyshould be installed on If there are no provisions for testingthe operation of the flow t het opside of t he pipe where t heywill be accessible. The units det ect iondevice on t hesystem,applicat ionof t heVSR SF is not should not be instailed wit hin6"(15cm)of a valve,drain or fitting recommended or advisable which changes the direct ionof the waterflow. The unit has a 1" The frequency of the inspect ion and t est ing and its associated NPT bushing forthreadingintoa non-corrosive TEE. See Fig. protective monitoring system should be in accordancewiththe 2 for proper TEE size, type and installation. applicable NFPA Codes and Standards and/or authorityhaving Screw t he device into t he TEE fit ingas shown in Fig. 2. Care jurisdict ion (manufacturer recommends quarterly or more fre- must be taken to properly orient the device for the direct ion of quent ly). PotteiElectricSignalCompany•2081 Craig Road,St.Louis,MO,63146-4161 •Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8800003-REV X PAGE 1 OF 2 MFG.#5400802-12/01 VSR-SF POTTER. VANE TYPE WATERFLOW 8 FOR SMALL PIPE The Symbol of Protection ALARM SWITCH WITH RETARD FIG. 1 DO NOT LEAVE COVER FIG. 2 OFF FOR EXTENDED Retard Adjustment: PERIOD OF TIME g,m•"° N0 To change time, turn knob � sil� (either direct ion)for desired ���Y L. FLOW � � time delay. Use the minimum � - "� use 1 11 16" / APPROX. ,,,i,....-„...--7...,;, � (4,3mm) amount of ret ardnecessary t o MOUNT SO ^ (WHITE) COM, ' I prevent false alarms. A "B" ARROW ON (RED) N.O.BUSHING �j (BLACK) N.C. settingis usually adequate for POINTS IN 1 DIRECTION OF t his. Factory set at"B". WATERFLOW 1�11. 'fjiti1"NPT I � Q\\\@ THREADED DEPTH FITTING ON DIRECTION OF 51 ALL SIZES WATER FLOW RUN OF THE ^ TEE MAY BE /\\�1 THREADED OR 4V � )10 SWEAT TYPEDIRECTION OF Screwthedevice intotheteefittingas shown.Care must be takento WATERFLOW properly orient the device for the direct ionof waterflow.On sweat tees,no WG. #737-31 threaded bushings,inserts,or adapt ersare permitt edunless t hey comply DWG. #802-30 wit ht he dimensions list ed in the chart below. Important: Imp ortant-The depth tot he inside bot t on7Df the tee should have the There are 12 paddles fur- TOUPREVENT LEAKAGE APPLY TEFLON TAPE SEALANT following dimensions: nished with each unit.One for TO MALE THREADS ONLY, DO NOT USE ANY OTHER each size ofthreaded,sweator TYPE OF LUBRICANT OR SEALANT, APPROXIMATE DEPTH REQUIREMENT plastic TEE as described in TEE SIZE THREADED SWEAT CTS, POLYBUTYLENE CPVC Fig. 2. These paddles have APPROX. RETARD SETTINGS (IN SEC.) raised lett eringt hat shows the o ABC D E 1" x 1" x 1" 2 1/16" 1 3/4" N/A 2 7/16" pipe size and typeof TEE that 0 10-25 20-40 35-55 50-70 60-90 I 1/2"x 1 1/2" x 1" 2 11/16" 2 1/4" 2N/A N/A 1/2" N/A t hey are t o be used with.The 2" x 2" x1" 3 3/16" 2 3/4" N/A N/A proper paddle must be used. DWG. #735-33 The paddle must be properly attached(see drawing) and the screw t hat holds the pad- dle must be securely tight- ened. SWITCHTERMINALCONNECTIONSCLAMPINGPLATETERMINAL FIG. 3 N"r I0Go0I#G CAUTION: �/ An uninsulat ed sect ion of a single conductorshould not be looped around t he t erminal and serve as two separat econnect ions. The wire must be � severed,t herebyproviding supervision of the connect ion in the event t hat ouIN DWG. #923-3 the wire becomes dislodged from under the terminal. FIG.4 TYPICALELECTRICALCONNECTIONS FIG. 5 NOTES: To remove knockouts: Place BELL TRANSFORMER cuss B STYLE B> 1. The model VSR-SF has two screwdriver at edge of knock- LOCALOR BATTERY POWERED END-OF-LINE RESISTOR CKT-(SEE NOTE) swit ches,one can be used t o outs,not in the center. COM COM. OPEN ON ALARM OPEN ON CLOSE ON operate a central station, CLOSE ON ALARM ALARM ALARM EOL rO rieta or remotesi nal- N,O. 19 RESISTOR ing proprietary 9 �N,C. N.O. �N,C, iunit, while the other is SIGNALING DEVICE SUPERVISED LOOP(SEE NOTE) used to operate a local au- COM, dible or visual annunciator. I / TYPICAL SWITCH ACTION OPEN ON CLOSE ON TO ADDL1 COIL FROM ALARM ALARM DEVICES 2. For supervised circuits see A OPEN ON CLOSE ON CONTROL OR RETURN "Switch Terminal Connec- � ALARM ALARM PANEL N.O. _N,C, TO CONTROL N.O. `N,C. tions" drawing and cant ion ;� DWG. #761-15 note(Fig.3). rl , o 4M - II 4111 APPLICATION WARNING! Due tot hepossibilityof unintended discharges caused by pressure surges,trappedair,or short retardtimes,waterflow switches t hat are monit oringwet pipe sprinkler syst ems should not be used as the sole init iat ingdevice t o discharge AF FF,deluge, or chemical suppression systems. PRINTED IN USA MKT.#8800003-REVX PAGE 2 OF 2 MFG.#5400802-12/01 RBVS le POTTER UNIVERSAL BALL The Symbol of Protection VALVE SWITCH UL and cUL Listed,FM,CSFM Approved Dimensions: (in cludin gmoun tin gclamps) f 07o:I k Large Clamps: 6"L x 5"W x 5.2"H ' — 15,2 cm Lx 12,7 cmWx13,2cmH •T. 1uivs 4 Small Clamps: 6"L x 4"W x 5.2"H 15,2 cm Lx•EiMli: Weight: With Large Clamps: 13.6 oz.(386,9 g.) I With Small Clamps: 11.0 oz.(311,2 g.) Enclosure: Non-CorrosiveComposite Material • - Environmental Limitations: I - NEMA 4 rated en closure when proper electrical r fittings are used.(IP67) - • Temperature range:-40°F to 150°F(-40°C to 65°C) • Not for use in hazardous location s Housing Cover Tamper:Activated by housing cover removal US Paten tNo.6,945,509 (Stock No.1000035 only) Contact Ratings: SPDT Contacts: 10A at 125/250 VAC RBVS Stock No. 1000040(w/o Cover Tamper) 2A at 30 VDC RBVS-T Stock No. 1000035(w/Cover Tamper) SPDT Cover Tamper: 3A at 250 VAC General Installation On Lever Handle(See Fig.2) The Model RBVS is design edto mon itor the fully open position of a ball valve 1. Select clamps andclampingbolts based upon pipe/valve size,see Table 1. installedin a sprinkler system.The un it will fit on most ball valves installedon 2. Insert rubber clamp grippers in to clamps,see Fig.2. back-flow-preventersan dalarm trim lines of dry,alarm,an ddeluge sprinkler 3. Place one clamp on top of pipe/ball valve n ear the valve handle an d valves.The switch operates if the ball valve han dleis moved from the open in sert clamping bolts through it. position.However,the switch does not track the position of the handle or ball. 4. Place other clamp over clamping bolts from beneath the installation and When the ball valve handle is in the open position,a spring-loaded switch button thread hex nuts on tothe clamping bolts,but don otfully tighten,(be sure will contact the valve handle.When the handle is moved from the open position, hex nuts seat properly in clamp hex recesses).(NOTE:Some installations this switch button extends to the tripped position,an dthe RBVS contacts change may require one of the mounting bolts to be inserted from the bottom of state,thereby open in gor closin ga circuit.A cover tamper switch is available and the brackets and then trimmed to allow the exten sionbracket to clear. is activated by the removal of the RBVS housing cover.If an attempt is made See Fig.4) to remove the RBVS by the removal of the moun tin gbrackets,the un it will be 5. Attach exten s ion bracket(if necessaryto use for position in g)to top clamp set into the tripped mode by this action. us in g'/4-20 X'/4"Hex bolt an dwasher,but do not fully tighten. The RBVS can be mounted to the hex portion of the ball valve or back-flow- 6. Attach"L"bracket(RBVS switch en closure is loosely attached to"L" preventeror to the adjoin in gpipe via two clamps.The RBVS is shipped with two bracket)to extension bracket using 1/4-20 X'/4"Hex bolt and washer,but p gp p p pp do not fully tighten. sets of moun tin g clamps to accommodate various pipe and valve sizes,refer to 7. Be sure ball valve is in the fully open position. Table 1.An"L"shaped and offset bracket for moun tin gthe switch en closure and g Slide loosely assembled RBVS switch en closureto a position that permits an exten sion bracket add to the moun tin gflexibility of the RBVS. See"Typical the switch button to con tactthe valve han dleapproximately 1"from its Moun ting Diagram"and"In stallation and Operation"on following page. in side end.See Fig. 1 for approximate location.Cut and remove the plastic Testing coatin gfrom the ball valve han dleto allow the RBVS switch button to The RBVS and its associated protective mon itorin gsystem should be tested contact(and be activated by)the metal of the handle. in accordance with applicable NFPA codes and standards and/or the authority 9. Tighten clamping screws alternately to an eventual 30 in-lbs.(minimum) havin gjurisdiction(manufacturer recommends quarterly or more frequently). of torque. 10. Maintain position of switch enclosure over valve handle an dsecure bolt Fig.! Internal Components that holds the exten sion bracket to the clamping assembly.It may be NORMALLY OPEN necessary to close valve to access this bolt. 11. Position"L"bracket so that it contacts the back edge of the valve han dle,an d NORMALLY CLOSED 41'1" .- secure its bolt.It may be necessary to close valve to access this bolt. COMMON � �=:� 12. With the actuator fullyretracted,position RBVS switch enclosureto 1i�` 1 r=� ���' � con tact the valve han dle squarely,see Fig.1. � ""� �' 13. With RBVS switch enclosure held squarely in contact with valve handle, STRAIN RELIEF q Y �� � A SWITCH BUTTON securely tighten the two tamper resistant screws on the backside of the COVERIIrBLRED — N.O. `•�e�C!1,L'.'�10 LOCATION TAMPER L RED — N.C. �J ON HANDLE enanClosure. WHITE — COM _....._„. ..111 14. Close an dopen the valve to verify operation.The actuator should easily retract when the valve handleis in the open position. 15. Fully open the valve. MOUNT SO ,, 16. Remove the cover and wire main switch and tamper switch if applicable. SWITCH BUTTON \I, pp IS APPROX. 1" FROM PLASTIC COATING REMOVED FROM Carefully route tamper switch wires through strain relief chann elfin switch HANDLE INSIDE END BALL VALVE HANDLE enclosure.Fully seat the wires in tothe bottom of the channel.See Fig.1. INCTH BUTTON C 17. Re lace RBVS switch en closure cover and securel tl hten cover screw. DWG #1086-1 CONTATACT AREA P Y g Potter Electric Signal Company,LLC•2081 Craig Road,St.Louis,MO,63146-4161 •Phon e:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5401086-REV U PAGE 1 OF 2 5/08 P POTTER RBVS UNIVERSAL BALL ® The Symbol of Protection VALVE SWITCH Fig.2 Typical Mounting Diagram Table 1 Clamp Sizing 1LENGTH Pipe Valve/Size Clamp Clamping Bolts ( SWITCH 1/2"to 3/4"(12,5 to 19mm) Small 10-32 x 2 1/2 ENCLOSURE .IINN 1"to 2"(25 to 50mm) Large 1/4-20 x 4" 1 "L" BRACKET 7 it ,,E-7 / _ HEIGHT Switch Terminal Connections,Clamping Plate Terminal — r EXT, BRACKET I A 5.2" �a� '�' 1^` (IF NECESSARY) —`�' �'o r, N �,� A CAUTION O �� AA\\�0�k An uninsulate of le termion nal CLAMPS or should n otbe looped around the terminal Mr� ■��� od andserve astwo se erateconnections.The pi CLAMP p'rr� o�•too�' DWOO 923-3 wire must be severed,thereby providin g GRIPPERS supervision of the con n ectionin the even t WIDTH 4" (SMALL) f that the wire becomes dislodged from DWG #1086-2 5" (LARGE) un der the terminal. Typical Electrical Connections LOCAL CIRCUIT TRANSFORMER OR BATTERY POWER STYLE D (CLASS A) SUPERVISED LOOP STYLE B (CLASS B) SUPERVISED CIRCUIT N.C. jSIGNALING COM, COM, TO N,C, DEVICE CONTTROL COM, NO END-OF-LINE RESISTOR UNI DWG. $1066-4 Tamper Switch Connections Fig.3 COVER TAMPER & RBVS CONNECTED COVER TAMPER & RBVS WIRED SWITCH ENCLOSURE TO THE SAME ZONE ON THE FACP TO SEPERATE ZONES COVER ` CM N,O,COM. D- TAMPER , OFFSET BRACKET COM, N.O. COM. ., /- FA --°."'J FACP COVER EOLR N.C, TAMPER FACP EOLR FAC EOLR I �� N.O. .t, *I, ao ® I 1 D.A.#1086-5 110 4/ . 1 I. li� Installation on Tee Handle(See Fig.3) ��k=- ` , 6RAGIV KET I,'' _rd_ 1. Select clamps and clamping bolts based upon pipe/valve size,see Table 1, •4f GP 2. Insert rubber clamp grippers into clamps,See Fig.3. ��/�./ I„ 3. Place one clamp on top of pipe/ball valve near th evalve handle and I CLAMPS 410.: 99,62 I"1 insert clamping bolts through it. 4. Place other clamp over clamping bolts from beneath the installation CLAMP GRIPPERS DWG X1086-3 and thread h exnuts onto th eclamping bolts,but do not fully tighten, (be sure h exnuts seat properly in clamp h ex recesses). 5. Loosely attach "L" bracket to the "offset" bracket and "offset" bracket to th eRBVS housing. Fig.4 6. Be sure ball valve is in thefully open position. (; ---------,- it 7. Slide loosely assembled RBVS switch enclosure to a position that RBVS ®� permits theswitch button to contact thevalve handle approximately l 1/2"from th e end of th e handle.Cut and remove th eplastic coating ILII from the ball valve h andleto allow th eRBVS switch button to contact R I J (and be activated by)th emetal of th eh andle. 0 8. Tighten clamping screws alternately and'/-20 X3/4"bolt to 30 in-lbs. (minimum)of torque. SOME INSTALLATIONS MAY 9. With the valve handle fully open, slide the RBVS housing down CAUSE INTERFERENCE '�' BETWEENMOUNTING BOLTAND ta untilthe switch o erates lus 1/8 inch.Ti hten tha screws holdin p p g g OFFSETBRACKET.INSTALL BOLTth eRBVS to the"offset"bracket. FROMBOTTOMANDTRIMAS PIPE 10.Remove theRBVS switch enclosure cover. NEEDEDTO CORRECT.11.Close and open the valve to verify operation. The actuator shouldeasily retract up wh enth evalve handle is in th eopen position. 12.Fully open thevalve. E \/ 13.Wire main switch and tamper switch(if applicable).Carefully route Im o tamper switch wires through strain reliefchannel in switch enclosure. Fully seat th ewires into th ebottom of th a channel.See Fig. 1. DWG#Loa 6-6 14.Replace RBVS switch enclosure cover and securely tighten cover screw. PRINTED IN USA MFG.#5401086-REV U PAGE 2 OF 2 5/08 AP c ® us _ANa A T APPROVED D 7-,,,,Tcal - 1E)-E'-n, Model 1011A 300 PSI Bronze Ball Valve,Model 7000 Pressure Relief Valve Factory Rated at 175 PSI with other settings available DIMENSIONS MODEL 1O11A - FRONT VIEW Orifice Size Available:3/8", '/is" 1/2", 17/32", ELO(5/8")", ESFR(3/a")*, &K25"" A SIZE A I B C D E F G H E 1 i,INLET iFieMiriNi 3/411 79/16" 11/2" 23/16" 35/8" 33/8" 113/16" 49/16" 63/8" TO 1 F —O II(191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) DRAIN H Ili it. . 1 :Mr)imi ,i 0 1" 79/16" 11/2" 23/16" 35/8" 33/8" 113/16" 49/16" 63/8" G •� O �, (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) `' ,z•z5 _z_,11611 11/4" 715/16" 111/16" 29/16" 41/4" 35/8" 115/16" 59/16" 51/2 (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 11/2" 815/16" 113/16" 31/4" 51/16" 37/8" 25/8" 81/4" 107/8" MODEL 1O11A - PLAN VIEW (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 2,, 815/16" 113/16" 31/4" 51A6" 37/8" 25/8" 81/4" 107/8" 4 A I.- (227 (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) *Available on 11/4" to 2" size units only **Available on 11/2" and 2" size units onlyTO 1 B J DRAIN DI + 111 0li THE MODEL 1O11A PROVIDES ALL OF THE FOLLOWING... III I. t :_. o ffL Fromthe 2007 Edition of NFPA 13 U ' '= Chapter8.16.2.4.1* Provisions shall be made to properly drain all partsof the system. T Chapter8.16.2.4.2 Drain connections,interiorsectional or floor control valve(s)— &8.16.2.4.3 shall be providedwith a drain connection having a minimum size as shown in Table 8.16.2.4.2. MATERIALS Chapter8.16.2.4.4 Drains shall discharge outside or to a drain cap ab leof handling Handle:Steel the flow of the drain. Stem: Rod Brass ChapterA.8.17.4.2 (Wet Pipe System)test connection is permittedto terminate into Ball:C.P. Brass a drain capableof accepting full flow...using an approved sight Body:Bronze test connection containing a smooth borecorrosion-resistant ValveSeat:Imp regnatedTeflorf orifice giving a flow equivalent to one sprinkler... Indicator Plate:Steel Chapter8.17.4.2.2 The test connection valve shall be readilyaccessib le. Relief Valve:Bronze Chapter8.17.4.2.4 shall be permittedto be installed in any location...downstream BypassFittings: Brass of the waterflowalarm. BypassTubing:Nylobraid Chapter8.17.4.3.1 (Dry Pipe System)a trip test connectionnot less than 1" in diameter,terminating in a smooth borecorrosion-resistant orifice, APPROVALS to provide a flow equivalent to one sprinkler... UL and ULC Listed:(EX4019 Chapter8.17.4.3.2 The trip test connection...with a shutoffvalve and plug not less &EX4533) than 1", at least one of which shall be brass. FM Approved Chapter7.1.2 -a gridded wet pipe system shall be providedwith a relief valve NYC-BSA No.720-87-SM set to operateat 175 PSI or 10 PSI in excess of the maximum system pressure,whichever is greater. Chapter8.16.1.2.3* A relief valve of not less than 1/2" in size shall be provided on the «+:** �, ****** �1 discharge side of the pressure-reducing valve set to operateat a ,*,**** pressure not exceeding 175 PSI. �, ChapterA.8.16.1.2.3 -considerationshould be given to piping the discharge fro mthe x��1� (pressure relief)valve MADE IN U.S.A. USA Patent # 4741361 and Other Patents Pending AGF Manufacturing Inc. Job Name: AG100 Quaker Lane,Malvern,PA 19355 Phone:610-240-4900 FFax:610-240-4906 Architect:Engineer: www.testandrain.com Contractor: