HomeMy WebLinkAboutB06-0100 Documents (CO)�
Community Dez�elopment Department
75 South Frontage Road
Vail, Colorndo USA 81657
CERTIFICATE OF OCCUPANCY
This certificate is issued pursuant to the requirements of Title 10, Section 10-1-2, ADOPTED CODES of the Vail Town
Code certifying that, at the time of issuance, this structure was found to be substantially in compliance with the various
ordinances of the town regulating building construction or use for the following:
Name and description of project
Address of project: 4418 Columbine
Purchase Residence N P/S
Vail, Colorado
Owner name and address: Tohn Purchase 1310 Greenhill Ct., Vail, Colorado 81657
IBC Edition: 2003 IRC Occupancy Group(s): R3 U Type(s) of Construction: VB
Permit Number(s): B06-0100 Occupant Load: Sprinkler System Y/N Type: Y
�
Marti Hae erle, Chief Building Official
�� �
Date
//���\ �.
.......:�
,..,...,
% \
1 %
/
I •
\ I
`l 1
� .
�TT�TrATF nF OCCUP��
�-;;.. - ..,;;� � %;.-,i �� ••,;� , .
r �,�• ��� �� '♦ ;�. ����,,,� iuiniu� a��,: �
� ��!.��.. d�i�iu� °�1 ./ \,�� ' �uun�n�►' I.:.�� ��
� �� :'•�� r �nm��u�� ��..�.�i ��,,����ii�`�vin uurl����°.�� ��I� �
i �►. : �. ��w wr/��a��,��.�_ � � � ♦ ��,.�n i�r�/I n• . _
: ' i�:���n �u�i . 'i �i�" ♦
� •p�i�► �\`;:��.�� . � ♦.,n��., �� �:. �
; i �� ����/f� �' � L � ..�� � � � i �� ;�.;� �. .,�\"�� •�� ; i
•I �' ,�'�'`. .� ��:��`'•'�:.i
�.e��'��`���''��`�.
�
�
� �//1 ��)�
�_ ���//
, .....,,, �
_ ..,...,i.:
TOWN OF VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2135
OWNER
VAIL FIRE DEPARTMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT
Job Address: 4418 COLUMBINE DR VAIL
Location.....: 4418 COLUMBINE DRNE-#2
Parcel No...: 210112201009
Project No :
APPLICANT
CONTRACTOR
PURCHASE, JOHN LAYTON
754 E POTATO PATCH DR
VAIL
CO 81657
VAIL ELECTRONICS, LTD.
PO BOX 460
MINTURN
COLORADO 81645
License: 756-S
VAIL ELECTRONICS, LTD.
PO BOX 460
MINTURN
COLORADO 81645
License: 756-5
Permit #: A08-0011
Status . . . : FINAL
Applied . . : 02/20/2008
Issued . . . 02/29/2008
Expires . .: 04/19/2009
02/20/2008 Phone: 970-949-4121
02/20/2008 Phone: (970) 827-9120
02/20/2008 Phone: (970) 827-9120
Desciption: NEW FIRE ALARM SYSTEM FOR A NEW DUPLEX
Valuation: $2,000.00
***►***s**a*�*****r**+**s*ss*********�s*sss**********���************ FEE SUMMARY *�*****rs****�*s**r**►***►***�*r*******+++**►****s�+�******■
Electrical---------> $0.00 TotalCalculatedFees--> $307.00
DRB Fee---------> $0. 00 Additional Fees----------> $0. 00
Investigation----> $0.00 TotalPermitFee--------> 5307.00
WillCall---------> $0.00 Payments------------------> $307.00
TOTALFEES--> 5307.00 BALANCEDUE--------> 50.00
F*#►*�F#*t####�t#►###**�####�F#*####*►#*4####4i�##�#*#*4*###t*i##**+k**##*###*M�#*t�*#t*#*###**t#t*tt*##t*#*#*i****#t####*##*�k*t***#f#4#�F*i**4##f##R#4
Approvals:
Item: 05600 FIRE DEPARTMENT
02/25/2008 DRhoades Action: AP Approved as noted:
1. Heat detector(s) required in all accessible crawlspaces and in all accessible
areas.
2. One set of stamped, approved plans must remain on-site.
3. Other corrections as shown on plans or found during inspections.
..�**��**�+�.:..**�.�.*+.+..*...*.*,�.,�.�..**.«..:.�.........:....».�..».*...:...*..::.*.:.,�.+..+.�:*.*..,:.**.+.+:�...*.....**:..:..,*...*:.:.�*.�
CONDITIONS OF APPROVAL
.�..�.**....*....*....�*.*...*..*...*«........*....�...*...*......*.......,�.*....*....***.«.*.��...�..*.*....**,�*.*.*.*....*.,�..�........�*..��.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970-479-2252 FROM 5:00 AM - 5 PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
******+*****************+***************+**************+**********************+****+++******
TOWN OF VAIL, COLORADOCopy Reprinted on 02-14-2013 at 15:58:06 02/14/2013
Statement
***************************+******+**************************+**********************+***�***
Statement Number: R080000219 Amount: $307.00 02/29/200809:02 AM
Payment Method: Check Init: LC
Notation: #2195/VAIL
ELECTRONICS
-----------------------------------------------------------------------------
Permit No: A08-0011 Type: ALARM PERMIT
Parcel No: 2101-122-0100-9
2101-122-0102-1
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE-#2
Total Fees: $307.00
This Payment: $307.00 Total ALL Pmts: $307.00
Balance: $0.00
****************************************************************+***************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 FIRE ALARM PERMIT FEES 75.00
PF 00100003112300 PLAN CHECK FEES 232.00
-----------------------------------------------------------------------------
E06-0163: Entries for Item:190
; By
AP B (SOUTH ) APPROVED. WA:
ON E07-0106 AS APPROVED.
Total Rows: 1
Page 1
- ELEC-Final
Date Unique_
Ke
09/29/2008 A000118
120
15:58 02/14/2013
� ��.��_.�
;,
Action
AP
Total Rows: 1
E06-0212: Entries for Item:190
Page 1
- ELEC-Final 15:58 02/14/2013
Date Unique_
TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-213 8
NOTE
DEPARTMENT OF COMMUNITY DEVELOPMENT
THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ELECTRICAL PERMIT
Job Address: 44] 8 COLUMBINE DR VAIL
Location.....: 4418 COLUMBINE DRNE
Parcel No...: 210112201009
Legal Description:
Project No :
OWNER PURCHASE, JOHN LAYTON
754 E POTATO PATCH DR
VAIL
CO 81657
APPLICANT A-PHASE ELECTRIC, LLC
PO BOX 1564
AVON
CO 81620
License: 313-E
CONTRACTOR A-PHASE ELECTRIC, LLC
PO BOX 1564
AVON
CO 81620
License: 313-E
Permit #: E07-0106
Status . . . : FINAL
Applied . . : 06/15/2007
Issued . . . O 1 /28/2008
Expires . .: 09/25/2008
06/15/2007 Phone: 970-949-4121
06/15/2007 Phone: 970-845-0188
06/15/2007 Phone: 970-845-0188
Desciption: PURCHASE DUPLEX WEST SIDE-ELECTRICAL FOR WEST SIDE OF
DUPLEX (AKA "A SIDE OR # 1 ")
Valuation: $0.00 Square feet: 1
ss►*�**+**�r*******+***�:***�*►*+**s****r*►*�++*s****r**+ss*�*r**s** FEE SUMMARY ♦****a►*�+�*******►*�*+**►****�*�**s*+**s�********+**»***�*•
Electrical---------> S 51. 7 5 Total Calculated Fees--> $ 5 9. 7 5
[nvestigation----> 50.00 AdditionalFees----------> (554.75)
Will Call---------> S3. 00 Total Permit Fee--------> $0. 00
TOTAL FEES--> S 5 4. 7 5 Payments------------------> S 0. 0 0
BALANCE DUE--------> S0. 00
s***t**+.�****r*ts*+�*a*�*t*t*+****r*******«�:***�►*t�*«+s+r******.s.:►►*t.t*s:�.*��»****t*s:s*.+n�****+***�**s*�*■s.s*r►****■s.:+++**saxr**t***.+.
Approvals:
Item: 06000 ELECTRICAL DEPARTMENT
06/15/2007 shahn Action: AP
Item: 05600 FIRE DEPARTMENT
+.«.»»...f...,�.......*�*�*.*..*..�,**.*+.**..►*..*.�..*.*�.*...*:..*:..*..�..+**«*.�.,�.«***�...:�.**...**......***.*...«....*s...+�.,�.*.*»..,...
CONDITIONS OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
■*:�::...**.+*.****..s«+::�.*.,:*«*.�...*.*s*.:*:*.:*:+..*.*.�*.:.,�..�s.*.,�+�.*.:►....�.�**«+.....*.:...*.**».*+.+*.�..�.*.:*.*+..*.*.*..*«f...*■.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
E07-0106: Entries for Item:190 - ELEC-Final 15:59 02/14/2013
Action Comments By Date Unique_
Ke
CR COULD NOT TEST SPA GFCI AS IT HAD shahn 08/01/2008 A000116
NO POWER. 255
REFER OUTLET MISSING BLANK AND IS
STILL GFCI.
PA OK FOR TCO. shahn 08/05/2008 A000116
PROVIDE #8CU BOND FROM SPA TO 341
COPPER WATER PIPE.
AP B(SOUTH ) APPROVED. SHAHN 09/25/2008 A000118
037
Total Rows: 3
Page 1
**********************+********+**********************+*********+**************+************
TOWN OF VAIL, COLORADOCopy Reprinted on 02-14-2013 at 15:59:18 02/14/2013
Statement
****+*****************************++********************************************************
Statement Number: R080000306 Amount: $254.00 03/20/200803:21 PM
Payment Method: Check Init: JS
Notation: 2012/JOHN
PURCHASE
-----------------------------------------------------------------------------
Permit No: M08-0054 Type: MECHANICAL PERMIT
Parcel No: 2101-122-0100-9
2101-122-0102-1
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE
Total Fees: 5254.00
This Payment: $254.00 Total ALL Pmts: $254.00
Balance: 50.00
****************************************+***************************************************
ACCOUNT ITEM LIST:
Account Code
MP 00100003111100
PF 00100003112300
WC 00100003112800
Description
MECHANICAL PERMIT FEES
PLAN CHECK FEES
WILL CALL INSPECTION FEE
Current Pmts
200.00
50.00
4.00
-----------------------------------------------------------------------------
M08-0054: Entries for Item:390 - MECH-Final 15:59 02/14/2013
Total Rows: 3
Page 1
TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
DEPARTMENT OF COMMUNITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
Job Address:
Location.....:
Parcel No...:
Legal Description:
Project No :
NEW (SFR,P/S,DUP) PERMIT
4418 COLUMBINE DR VAIL
4418 COLUMBINE DRIVE
210112201009
PRJOS-0382
OWNER PURCHASE, JOHN LAYTON
754 E POTATO PATCH DR
VAIL �
CO 81657
CONTRACTOR PURCHASE DEVELOPMENT, LLC
PO BOX 1391
VAIL
COLOR.ADO 816 5 7
License: 322-A
Permit #: B06-0100
Status . . . .
Applied . . :
Issued . . .
Expires.....:
ISSUED
04/27/2006
07/31/2006
O1/27/2007
04/27/2006 Phone: 970-949-4121
04/27/2006 Phone: 390-9943
�� .�
� �
i� �J
Desciption: NEW CONSTRUCTION OF PRIMARY/SECONDARY RESIDENCE
Occupancy Type Factor Sq Feet Valuation
Totals... 10,030 $1,575,000.00*
Number of Dwelling Units: 2 Town of Vail Adjusted Valuation: 1,575,000.00
Fireplace Information: Restricted: Y /i of Gas Appliances: 2 # of Gas Logs: 2 Jt of Wood Pallet: 0
******************************************************s********a***sx FEE SUMMARY *********x*****************************«**s****************
Building------> $�, 70� . 50 Restuarant P1an Review--> $0. 00 Total Calculated Fees-----> $12, 720.38
Plan Check---> $ 5, 0 0 9. 8 8 Recreation Fee------------ > $ o. 0 o Addirional Fees------------ > $ o. 0 0
Invesdgation-> $ o. 0 o TOTAL FEES-------------> $12 , 7 2 0. 3 8 Total Pernut Fee-----------> $12 , 72 0. 3 8
Wi11 Ca11-----> $3.00 Payments-------------------> $12, 720.38
BALANCE DUE---------> $0. 00
***************rt********a******************s****�********s***s*******s**r******�*s***********s*********s*s*a**s*****r**x***********r*s*s*�*sa*x**
Approvals:
Item: 05100 BUILDING DEPAR.TMENT
05/26/2006 cgunion Action: CR see lhn
07/27/2006 cgunion Action: AP approved revised, corrected drawings, see
conditions
and 1/h/n
Item: 05400 PLANNING DEPARTMENT
07/28/2006 eer Action: AP approved by planning based on letter dated
072806; see
file.
Item: 05600 FIRE DEPARTMENT
07/26/2006 JJR Action: AP
Item: 05500 PUBLIC WORKS
05/O1/2006 gc
walls over 4
foot and double teir
Do not need seperate
07/12/2006 gc
plan.
07/25/2006 gc
walls.
Action: DN
retaining walls.
zone in TOV Right
Action: COND
Action: DN
Need to provide stamped PE drawings for
of Way.
Provide Public Way permit and staging
Provide stamped drawings for boulder
Must include factor of safty, design perameters, and design assumptions.
Soil nail walls to be called out on site plan and show limits of nails.
Item: 05550 ENGINEERING CIVILS
:*********************************�:***************�*�*******�*******�:*�******:****�**.****�*******************************:********************
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, iilled out in full the information required, completed an accurate plot plan
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE Y TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4
PM. �/
f
SIGNATU OF WNER OR CONTRACTOR FOR H1M5�Lr A1vli uwN�r
PAGE 2
*********�***�****************************��*****************�x�***�*************�*************�*********
CONDITIONS OF APPROVAL
Permit #: B06-0100 as of 07-31-2006 Status: ISSUED
******�x**�****�:��**********�:***********�********�*****�x*******�*�*�*********�*�:��****�*�*�:*�:*�**�**�***�:
Permit Type: NEW (SFR,P/S,DUP) PERMIT Applied: 04/27/2006
Applicant: PURCHASE, JOHN LAYTON Issued: 07/31/2006
Job Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE .
Parcel No: 210112201009
*�x*��*****�x*****�*****************�**�****�*****�x******�*****�*****�:*�*��************:x**�**�x�:******�:�***
CONDITIONS
**�x��**�*****�x��**�*********��x*****�****�:*�x�******************�*��x���*******�******:�***********�*:x*�***�
Cond: 33
(PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL
BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION.
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: CON0008010
Fire sprinkler system required and shall comply with NFPA 13(2002) and VFES
standards.
Cond: CON0008011
Monitored fire alarm system required and shall comply with NFPA 72(2002) and
VFES standards.
Cond: 16
(BLDG.): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R313 OF THE 2003 IRC.
Cond: 18
(BLDG.): STAIRWAYS ARE REQLTIRED TO MEET SECTION R311.5 OF THE 2003 IRC OR
SECTION 1009 OF THE 2003 IBC.
Cond: 19
(BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTION
1012 OF THE 2003 IBC.
Cond: 39
(BLDG): EMERGENCY ESCAPE AND RESCUE OPENINGS ARE REQUIRED TO MEET SECTION R310
OF THE 2003 IRC OR SECTION 1025 OF THE 2003 IBC.
Cond: CON0008315
OPEN HOLE SOILS REPORT REQUIRED PRIOR TO FOOTING INSPECTION.
Cond: CON0008316
FINAL SOIL NAIL WALL INSTALLATION DRAWINGS AND WRITTEN APPROVAL REQUIRED FROM
SOIL NAIL ENGINEER AND FOUNDATION STRUCTURAL ENGINEER PRIOR TO FOOTING
INSPECTION.
Cond: CON0008320
No non-conforming crawl spaces or additional GRFA will be allowed at time of
TCO, per Staff letter to applicant dated 072806
********************************************************************************************
TOWN OF VAIL, COLORADO Statement
********************************************************************************************
Statement Number: R060001106 Amount: $7,710.50 07/31/200609:43 AM
Payment Method: Check Init: DDG
Notation: Purchase 1801
----------------------------------------------------
Permit No: B06-0100 Type: NEW (SFR,P/S,DUP) PERMIT
Parcel No: 2101-122-0100-9
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE
Total Fees: $12,720.38
This Payment: $7,710.50 Total ALL Pmts: $12,720.38
Balance: $0.00
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code
--------------------
BP 00100003111100
WC 00100003112800
Description
------------------------------
BUILDING PERMIT FEES
WILL CALL INSPECTION FEE
-------------------------------------------------------
Current Pmts
7,707.50
3.00
�
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIG O „���
Project #:
�� � � � Building Permi #: ��
_ �' ������4� (l���titn�
��� �� �
75 S. Frontage Rd.
Vail, Colorado 81657
TOWN OF VAIL BUILDING PERMIT APPLICATION
Separate Permits are required for electrical, plumbing, mechanical, etc.!
CONTRACTOR INFORMATION
eral Contractor: Town of Vail Reg. No.: Contact Person
w'� � l�- e v.r�o r�u�.F 3�. 2— A �,�-C. G� I�
iil address: 'v4. rc�ar�.'41co►xc�+.sF:ne.f� ott Fax #: q
rc
tractor Signature: .�,¢�e-�1E•'�-«e:k-s �
` M;K y � IK�d +�p.ts cs�.,P+
l�
i hone #'s:
' �70 37G-Z�I Z�t
3�fs- 0 9 S�
• �-*,K .
COMPLETE VALUATIONS FOR BUILDING PERMIT Labor 8 Materials
BUILDING: $' 6'L� fJ0 O ELECTRICAL: $ Z�D� 0 OTHER: $ �) I a I� OOO
PLUMBING: $ (��, A-B-Q MECHANICAL: $ /aO �qZ7'� TOTAL: $ l, S �'S �'O
*****'"t'"t****'t"`***''""`*�"t***"""*""`******'t't******FOR OFFICE USE ONLY'"
Type of Construction � � �,4,�j,;_.
Occupancy Group: Accepted By: _ ��
,- • ^
F:\cdev\FORMS\Permits\Building\building_permit.DOC J Page 1 f �
� ���oe�
�� APR 2 6 2006
02/09/2005 I
TOWN OF VAIL
TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-213 8
DEPARTMENT OF COMMUNITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW (SFR,P/S,DUP) PERMIT Permit #: B06-0100
Job Address: 4418 COLUMBINE DR VAIL Status ...: ISSUED
Location.....: 4418 COLUMBINE DRNE Applied ..: 04/27/2006
Parcel No...: 210112201009 Issued ..: 07/31/2006
Legal Description: Expires.....: O 1/27/2007
Project No : PRJOS-0382
OWNER PURCHASE, JOHN LAYTON
1310 GREEHNILL COURT
VAIL
CO 81657
CONTRACTOR PURCHASE DEVELOPMENT,
PO BOX
EAGOE
COLORADO 81631
License: 322-A
LLC
04/27/2006 Phone: 970-390-9943
04/27/2006 Phone: 970-328-4226
Desciption: NEW CONSTRUCTION OF PRIMARY/SECONDARY RESIDENCE
Occupancy Type Factor Sq Feet Valuation
Totals... 10,030 $1,575,000.00*
Number of Dwelling Units: 2 Town of Vail Adjusted Valuation: 1,575,000.00
Fireplace Information: Restricted: Y # of Gas Appliances: 2 # of Gas Logs: 2 # of Wood Pallet: 0
*s**+****t�****�s*s�sst+**a*****+ss**ss**ss**t****rs**rss**s*s**sa�r+ FEE S UMMARY s..s.ss►a«s�*s�a*s*�:*a■s*:�■**sa:*.ss*ss**sss.s.:�+s.*s■.•
Building-----> $ �, � o �. 5 o Restuarant Plan Review--> $ 0. o o Total Calculated Fees----> $13 , 10 5. 3 8
Plan Check---> S 5, o 0 9. s 9 Recreation Fee------------> 5 0. o o Additional Fees-----------> S o. o 0
Investigation-> $ o. o o TOTAL FEES-------------> $13 , 10 5. 3 8 Total Pertnit Fee-----------> $13 , 10 5. 3 8
W ill Call-----> $ 3. 0 0 Payments-------------------> $13 , 10 5. 3 6
BALANCE DUE---------> $0. 00
#i*#*#*#####4#+k#i*#f###t►######4##*#R########i##*►##t#4#*###############�t##4*####f#►t*######�*#####i##►#t##4t#►##f###*k*#*##*##4*#####iR►*##it4##
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/26/2006 cgunion Action: CR see lhn
07/27/2006 cgunion Action: AP approved revised, corrected drawings, see c
and 1/h/n
02/22/2008 cgunion Action: AP APPROVED REVISED SHEETS 514, S15 AND UPDAT]
Item: 05400 PLANNING DEPARTMENT
07/28/2006 eer Action: AP approved by planning based on letter dated
file.
Item: 05600 FIRE DEPARTMENT
07/26/2006 JJR Action: AP
Item: 05500 PUBLIC WORKS
05/O1/2006 gc Action: DN Need to provide stamped PE drawings tor wa
foot and double teir retaining walls.
Do not need seperate zone in TOV Right of Way.
07/12/2006 gc Action: COND Provide Public Way permit and staging plan
07/25/2006 gc Action: DN Provide stamped drawings tor boulder walls
Must include factor of safty, design perameters, and design assumptions.
Soil nail walls to be called out on site plan and show limits of nails.
02/06/2008 csalli Action: COND Prior to TCO, a written and stamped letter
Engineering, Inc. stating the construction ot the boulder retaining walls meet thf
Item: 05550 ENGINEERING CIVILS
#if#s####*#1*######*##f#�###*###*#st######*#*t**##**#►####*#t#**#t#ft##►##*###a#�########t#►#*►####ti***######*#####�##t#�#####tt#####►i#�*####�#
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as reyuired is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV�NCE BY TE �EPHONE AT 47�9-2149 OR AT OUR OFF[CE FROM 8:00 AM - 4 PM.
SIGNATURE OF OWNE�i�R CONTRACTOR FOR HIMSELF AND OWNER
PAGE 2
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit #: B06-0100 as of 03-OS-2008 Status: ISSUED
********************************************************************************************************
Permit Type: NEW (SFR,P/S,DUP) PERMIT
Applicant: PURCHASE, JOHN LAYTON
Job Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRNE
Applied: 04/27/2006
Issued: 07/31 /2006
Parcel No: 210112201009
********************************************************************************************************
CONDITIONS
********************************************************************************************************
Cond: 33
(PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL
BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION.
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: CON0008010
Fire sprinkler system required and shall comply with NFPA 13(2002) and VFES
standards.
Cond: CON0008011
Monitored fire alarm system required and shall comply with NFPA 72(2002) and
VFES standards.
Cond: 16
(BLDG.): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R313 OF THE 2003 IRC.
Cond: 18 �
(BLDG.): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC OR
SECTION 1009 OF THE 2003 IBC.
Cond: 19
(BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTION
1012 OF THE 2003 IBC.
Cond: 39
(BLDG): EMERGENCY ESCAPE AND RESCUE OPENINGS ARE REQUIRED TO MEET SECTION R310
OF THE 2003 IRC OR SECTION 1025 OF THE 2003 IBC.
Cond: CON0008315
OPEN HOLE SOILS REPORT REQUIRED PRIOR TO FOOTING INSPECTION.
Cond: CON0008316
FINAL SOIL NAIL WALL INSTALLATION DRAWINGS AND WRITTEN APPROVAL REQUIRED FROM
SOIL NAIL ENGINEER AND FOUNDATION STRUCTURAL ENGINEER PRIOR TO FOOTING
INSPECTION.
Cond: CON0008320
No non-conforming crawl spaces or additional GRFA will be allowed at time of
TCO, per Staff letter to applicant dated 072806
***********************************�**********�**********+**********+*****************+*****
TOWN OF VAIL, COLORADO Statement
*+*r*��*********************************+**+***********************+***�****************�***
Statement Number: R080000247 Amount: $385.00 03/05/200801:39 PM
Payment Method: Check Init: DDG
Notation: Purchase
Development, LLC 1268
----------------------------------------------------------------------
Permit No: B06-0100 Type: NEW (SFR,P/S,DUP) PERMIT
Parcel No: 2101-122-0100-9
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE
Total Fees: $13,105.38
This Payment: $385.00 Total ALL Pmts: $13,105.38
Balance: $0.00
s****r********+***�******************��*****�******+****************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300 PLAN CHECK FEES 385.00
---------------------------------------------------------------------------
TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-213 8
DEPARTMENT OF COMMUNITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW (SFR,P/S,DUP) PERMIT Permit #: B06-0100
Job Address: 4418 COLUMBINE DR VAIL Status ...: ISSUED
Location.....: 4418 COLUMBINE DRNE Applied ..: 04/27/2006
Parcel No...: 210112201009 Issued ... 07/31/2006
Legal Description: Expires.....: 03/20/2008
Project No : PRJOS-0382
i OWNER
CONTRACTOR
PURCHASE, JOHN LAYTON
1310 GREEHNILL COURT
VAIL
CO 81657
PURCHASE DEVELOPMENT, LLC
PO BOX
EAGOE
COLORADO 81631
License: 322-A
04/27/2006
04/27/2006
Phone: 970-390-9943
Phone: 970-328-4226
Desciption: NEW CONSTRUCTION OF PRIMARY/SECONDARY RESIDENCE
Occupancy Type Factor Sq Feet Valuation
Totals... 10,030 $1,575,000.00*
Number of Dwelling Units: 2 Town of Vail Adjusted Valuation: 1,575,000.00
Fireplace Information: Restricted: Y # of Gas Appliances: 2 # of Gas Logs: 2 � of Wood Pallet: 0
s**s+4+ssssssr+ss*sas*s*+sa*�s*►►ass*ss**�*ras**a***s*sss+*►s+ss**srs FEE SUMMARY sa*srs:►*s�s*+■+*�+:**►***s■**s�■*�s■s►s■s+*+:*ss.**s.s*sf.
Building-----> $ �, � 0 �. 5 0 Restuarant Plan Review--> $ o. 0 0 Total Calculated Fees-----> $ i 3, z 15 . 3 8
Plan Check--> $ 5, 0 0 9. 8 8 Recreation Fee---------> S o. o o Additional Fees-----------> S o. o 0
Investigation-> $ o. 0 o TOTAL FEES-----------> $13 , z 15 . 3 8 Total Permit Fee----------> $ i 3, z 15 . 3 B
W ill Call----> $ 3. 0 0 Payments-----------------> $13 , 215 . 3 8
BALANCE DUE--------> $ 0. 0 0
#►i######it###+k#####t#*########i#R##f#*t######f##*t#######tR#####**##t##t##�###fi##}*t#*###t#########4###########**####+k####►##*4###i#ft#f##t###�
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/26/2006 cgunion Action: CR see lhn
07/27/2006 cgunion Action: AP approved revised, corrected drawings, see �
and 1/h/n
02/22/2008 cgunion Action: AP APPROVED REVISED SHEETS 514, S15 AND UPDAT]
04/08/2008 cgunion Action: AP REVISIONS FOR ADDITION OF MECHANICAL ROOM i
Item: 05400 PLANNING DEPARTMENT
07/28/2006 eer Action: AP approved by planning based on letter dated
file.
03/28/2008 RLF Action: AP revisions dated 03/27/08 approved.
Item: 05600 FIRE DEPARTMENT
07/26/2006 JJR Action: AP
Item: 05500 PUBLIC WORKS
05/O1/2006 gc Action: DN Need to provide stamped PE drawings tor wa.
foot and double teir retaining walls.
PAGE 2
'� ********************************************************************************************************
CONDITIONS OF APPROVAL
Permit #: B06-0100 as of 04-11-2008 Status: ISSUED
********************************************************************************************************
Permit Type: NEW (SFR,P/S,DUP) PERMIT Applied: 04/27/2006
Applicant: PURCHASE, JOHN LAYTON Issued: 07/31/2006
Job Address: 4418 COLUMBINE DR VAIL �
Location: 4418 COLUMBINE DRNE
Parcel No: 210112201009
********************************************************************************************************
CONDITIONS
********************************************************************************************************
Cond: 33
(PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL
BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION.
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: CON0008010
Fire sprinkler system required and shall comply with NFPA 13(2002) and VFES
standards.
Cond: CON0008011
Monitored fire alarm system required and shall comply with NFPA 72(2002) and
VFES standards.
Cond: 16
(BLDG.): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R313 OF THE 2003 IRC.
Cond: 18
(BLDG.): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC OR
SECTION 1009 OF THE 2003 IBC.
Cond: 19
(BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTION
1012 OF THE 2003 IBC.
Cond: 39
(BLDG): EMERGENCY ESCAPE AND RESCUE OPENINGS ARE REQUIRED TO MEET SECTION R310
OF THE 2003 IRC OR SECTION 1025 OF THE 2003 IBC.
Cond: CON0008315
OPEN HOLE SOILS REPORT REQUIRED PRIOR TO FOOTING INSPECTION.
Cond: CON0008316
FINAL SOIL NAIL WALL INSTALLATION DRAWINGS AND WRITTEN APPROVAL REQUIRED FROM
SOIL NAIL ENGINEER AND FOUNDATION STRUCTURAL ENGINEER PRIOR TO FOOTING
INSPECTION.
Cond: CON0008320
No non-conforming crawl spaces or additional GRFA will be allowed at time of
TCO, per Staff letter to applicant dated 072806
Do not need seperate zone in TOV Right of Way.
I 07/12/2006 gc Action: COND Provide Public Way permit and staging plan
07/25/2006 gc Action: DN Provide stamped drawings tor boulder walls
Must include factor of safty, design perameters, and design assumptions.
Soil nail walls to be called out on site plan and show limits of nails.
02/06/2008 csalli Action: COND Prior to TCO, a written and stamped letter
Engineering, Inc. stating the construction ot the boulder retaining walls meet thE
Item: 05550 ENGINEERING CIVILS
•##f######i#####*###fk###ii*#####*####i##*####t#�#�##t#####4###t####*#t#►*#►#4**�###4*###t##i#t###tt##f####t##4#####i########*#Rt*tt#######�##�#*
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV
SIGNA
BY EPH NE
1
OF OWNER OR
479-2y�9 � AT OUR OFFICE FROM 8:00 AM - 4 PM.
FOR HIMSELF AND OWNER
*+**.****+**************+�***�*****�*****************�*r************************************
TOWN OF VAIL, COLORADO Statement
�+�***�**�***�**+�*********�****r******r******�**+****************************************rr
Statement Number: R080000428 Amount: $110.00 04/11/200810:33 AM
Payment Method: Check Init: DDG
Notation: Purchase 1303
---------------------------------------------------------------------
Permit No: B06-0100 Type: NEW (SFR,P/S,DUP) PERMIT
Parcel No: 2101-122-0100-9
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE
Total Fees: $13,215.38
This Payment: $110.00 Total ALL Pmts: $13,215.38
Balance: $0.00
**********�*************+*********************�***********�******�*************************�
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300 PLAN CHECK FEES 110.00
-----------------------------------------------------------------------------
�
�p�.�. � ACCEPTED IF IN�� �j�INSIGNE � � o � �O
� v M�l� • �—
D aF��� ��� :�. ;
�i���,�I, s ��/1�51� T WN OF VA�L BUILDING PERMIT
Separate Permits ar quired for electrical, piumbing, mechanicai, etc.!
75 S. Frontage Rd. -r�WN �F VA�L
Vail, Colorado 81
***Ali Revision submittals must include the Field Set of approved plans. No further insaections
will be performed until the revisions are approved. '""""`
CONTRACTOR INFORMATION
_ ,-,.,.,.. r,f \/�il Ron N� • contact and Phone #'s:
�.onuac�vi. � �•,••�� ,,.
� Gl G2. // �/
�ION: JOE, JR, CHARLIE, GREG, CHRIS
tor SianaturE: _ i . _ A /
ll lrt/,�i �1,� 37G -�35 �--
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor 8� Ma1
REVISED AMOUNT: $ � � a'� ELECTRICAL: $ OTHER: $
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
For Parcel # Contacf Ea le Coun Assessors �ce at 970-328-8640 or visit
�j��- Olbo
Job Name:
Legal Description � Lot: 3� Block:
Filing:
Job Address: � f �
35og
Subdivision:
�°�-`il � _
�l�b��h�e, D�
' l�,orh,
hon . 3-�i d 99 3
>hone:� , , „ `�
�hone ��
�9�f9 - �� o0
REA N FOR 1 IoNS�
� r �. � j��. ra�rM r�.doC►� �vr
Work Class: New � Addition ( ) Remodel ( ) Repair ( ) Demo ( ) Other ( )
Work Type: Interior � Exterior O Both O Does an EHU exist at this location: Yes O No O
Type of Bldg.: Single-family ( ) Twafamily � Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( )
No. of Existing Dwelling Units in this building: � No. of Accommodation Units in this building: �
of
of
a
: Gas
:d: Gas
5( �
a Fire
s �rr��+C I ICC AAII V
)
�
�
�
�
�
F:lcdev�FORMS�Permits\Building�building_revision_4-1&2007.doc Page 1 of 1 4/182007
July 28, 2006
Mr. John Purchase
1310 Greenhill Court
Vail, CO 81657
Mr. Steve Riden, AIA
Steven James Riden Architect PC
PO Box 3238
Vail, CO 81658-3238-
(fax) 970.949.0304
�ILE C !�
a� �
Re: 4418 Columbine Drive/Lot 3, Bighorn Subdivision
PRJ05-0382, B06-0100, DR605-0445
Purchase Residence
Dear Sirs,
Thank you for submitting revisions to the building permit for the Purchase residence referenced above. The
Planning Department has approved the building permit drawings since alt conditions of Design Review Board
approval have been satisfied.
Please note that per the conversation that occurred on Monday, July 24th between us (including Chris Gunion,
Plans Examiner), at the time of Temporary Certificate of Occupancy all crawl spaces existing with a head
height five feet (5') or greater will be required to be backfilled to an appropriate level as determined by Staff.
No crawl spaces proposed on the plans or otherwise, will be allowed to be converted to Gross Residential
Floor Area (GRFA) at any point throughout the duration of the structure.
Staff will reference the
structure for TempoFat�
originally approy�d am
Please don
.4
Reed
ving sheets within the building permiUDRB set of plans when reviewing the
tificate of Occupancy requirements: Sheets SF1 — SF8, which clearly show the
of GRFA in detail.
call with remaining questions or concerns. Best of luck as construction commences!
Charlie Davis; Chief Building Official, Town of Vai�
Ch�union; Building Plans Examiner, Town of Vaif
v
J �
� •�
1
�� � �► #i 1 � �� i1s'
De�itinent of Community Deve%pment
Building Safety and Inspection Se�vices
75 South Fronbge Road
�ail, Co%rado 81657
970-479-2138
FAX 970-479 2452
www, vailgov.com
Qf�ice Go��f
RJILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS:
TO: Contractor/Applicant Architect
Purchase Development Steve Riden
John Purchase or Mike Gilkey proj# none
FAX/Email #: mikyilk@netscape.com 949.0304
johnpurchase@comcast. net
NUMBER OF PAGES: 2
FROM• Chris Gunion, Building Plans Examiner
DATE:. 05/26/2006
BUILDING PERMIT #: B06-0100
OWNERS NAME: Purchase
SITE ADDRESS: 4418 Columbine Drive
OCCUPANCY GROUP: R-3/U
TYPE OF CONSTRUCTION: �-B
NUMBER OF STORIES: 3+basement
BUILDING AREA: ?
The documents submitted for this project have been reviewed for compliance with the 2003
International Building Code, 2003 International Residential Code, 2003 International Mechanical
Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code, 2003 International
Energy Conservation Code and 2002 National Electrical Code as modified and adopted by the Town of
Vail.
The fo/%wing aomments wi// ne�ed to be addr�esse�d prior �v issuanae of a bui/ding pe�nit;
For processing:
. Please submit four complete sets of revised construction documents containin4 the reauested
information with all plan revision items clouded or otherwise identified.
• Please re�ond in writing to each comment bv marking the attached list or creatina a resqonse
letter Indicate whichplan sheet detail s�ecification or calculation shows the reauested
information Please send revisions to the attention of the plans examiner with the buildi�
permit apqlication number noted.
• Please be sure to include on the resubmittal the engineer's or architect's'�wet" stamp, siQnature,
registration number and date on the cover pa4e of anv structural calculations, all structural
details and structural sheets of the plans For commercial or multi-familv proiects all sheets of
the plans must be stamped.
�
�
Architectural Comments:
1 Amend site plan and floor plans to show location of the proposed duplex lot split property line.
2 Amend parly wall detail. Clearly reference detail on the floor plans. Show complete parly wall detail
from foundation to roof. Common walls adjacent to property line shall consist of (2) 1 hour wall
assemblies per the IRC section R302, "Location on Lot" provisions. Provide a UL or gypsum
association listing for the 1 hour wall assemblies
3 Exterior walls of R-3/U-1 occupancies are required to be one hour fire resistive construction where
located less than 3' from property line. Revise plans. Provide a UL or gypsum association listing for
the 1 hour wall assembly (R302)
4 Openings are not permitted in exterior walls of R-3/U-1 occupancies are not permitted less than 3'
from properly line. Revise plans at window locations within 3' of the property line (R302)
5 Amend plans to specify 1 hour occupancy separation between garage and dwelling unit (R309.2)
-Common walls between garage and dwelling must be protected with 1/2" gypsum board on garage
side
-Garages beneath habitable rooms shall be separated from all habitable rooms by not less than 5/8"
type X gypsum board
-All structural members supporting living space over garage must be protected by 1/2" gypsum board
on garage side of walls, beams and posts.
6 Amend plans to show 1/2" gypsum board on the enclosed side of usable space under stairways.
(R311.2.2)
7 Amend plans to provide at least one operable window or door approved for emergency escape for
master bedroom, sheet A6. (R310.1)
Opening must comply with all of the following:
-Maximum finished sill height of not more than 44" above the floor
-Shall have a minimum net clear opening area of 5.7 square feet
-The minimum net clear opening height dimension shall be 24"
-The minimum net clear opening width dimension shall be 20"
8 Specify crawl space cross-ventilation at 1 sq. ft. per 150 sq. ft. of the crawl space floor area.
Indicate location and size of vents. (R408) Also show location and size of crawl space access.
(R408.3)
9 Decorative shrouds shall not be installed at the termination of chimneys for factory-built fireplaces
except where such shrouds are listed and labeled for use with the specific factory built fireplace
system and installed in accordance with the manufacturer's installation instructions. (R1004.3)
10 Amend plans to show proposed location of inechanical room.
11 Amend building sections AA and DD to coordinate with the structural foundation plan. Architecturat
sections do not match foundation walls per the structural plans. Show actual finish grades at crawl
spaces, actual concrete foundation top of wall and show all proposed void spaces at interior and
exterior soil nail walls. Show all crawl space areas and crawl space heights on the floor plans.
Submit revised GRFA calculations for Planning Department review.
12 Show all soil nail walls and extent of soil nails on the site plan.
w
Structural Commeats: .
13 Please clarify note on foundation design regarding "adjacent grade must 6e soil nailed by others".
No additional retaining walls are shown on the plans and no soil nail wall design was provided.
Please submit all necessary plans for review. The engineer of record will need to provide written
verification they have reviewed the retaining wall plans by others and coordinated the foundation
plan accordingly. Please specifically address any crawl space foundation pads located adjacent to the
soil nail walls and maximum backfill/void requirements between the concrete foundation walls and
the soil nail wall. The soil nail wall design must also show the "bridging" to the concrete foundation
walls.
14 Revise foundation plan accordingly per architectural comment #11. Coordinate with architectural
plans. Additional foundation walls may be necessary to maintain a maximum 5' crawl space height.
15 Amend I joist specifications per BCI 2006 product guide. 450 series are no longer manufactured.
16 Please include (4) sets of "wet stamped" boulder retaining wall construction details.
Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance of
a permit, please check � requested information is included with the resubmitted plans. Please submit
revised plans as a complete set. Partial plan resubmittals will not be reviewed.
F:\cdev\CHRIS\PERMIT.COMMENT'S\B06-OlOU\B06-0100 DOC
.
.�
� �
• lutions .inc
J
E N G I N E E R I N G
Letter of Record
Date:
07.25.06
To:
Town of Vail Building Department
Chris Gunion (Building Plans Examiner)
Proiect/Job Number.
Lot 3 Bighom Subdivision (4418 Columbine Drive) Job # 0208-05
PO BOX 2494
AVON, CO 81620
PH. 970.949.7100
FAX. 970.949.3377
�0 �
3�b - �ta�3
This "Letter of Record" is in regards to the following concems that the Town of Vail plans examiner
(Chris Gunion) had on the above referenced project. All soil nailed walls indicated on the foundation
plan (sheet S2) will be soil nailed by Great Divide Construction, Inc. and should follow all
recommendations provided by the Hartmann Engineering, Inc. report, dated June 14, 2006, that has
been provide to you. We have reviewed this report with comments conceming certain walls that were
not indicated on the report that should be soil nailed. I have been in contact with Burt Hartmann of
Hartrnann Engineering, Inc. and have an understanding that the report is a preliminary analysis. As
excavation begins, site visits will have to be made periodically to evaluate the existing conditions. Our
office will be in close contact with Great Divide Construction and Hartmann Engineering during the soil
nailing process to ensure that the structure can be constructed according to the revised structural plans
dated 07-25-06. It has been indicated on plan that the "top of the soil nailed wall not go beyond isolated
footing". Also the maximum backfilUvoid requirements and bridging between soil nailed walls and
foundation walls have been addressed on specified details as indicated on sheet S2. If there are any
questions or concems please call me at (970)-949-7100.
•
� �, �
_-_ __ _ __ Lot 3 � � 1 l�-� S �(� . 3 A� �
� ,
_ ��I �_ C�( �v►�b i vv2. ��-. _
I' _ - __ ���I' �IN1� �_ . � �� - � � d� _
�
_ _
_ � 81/�5� _�'D ���'Unl� G4 IM 1N_l_�.1_!��5 _. _ -
� __ -- _
_ . ._
_ _ _ __ _ -- � . 5 l��a?� �_�1 � � --� �� _ . __ _ _ _
� __
_ .SI�:�E- ,A� t`� ��a � �� g, �'lr�,n�.��.,P,�-�s �� -� �5
_ _ 3. 5_l���s_ � l � 1�� _ _ _
__ _ :
_ �. S1�-e�-�s � l -� A� _ _ _ ___ _ ;
__
.S I� _ A 1. . _ _
_ _
_ i�. Sln�e,�_ A 1
_ _ _ .o __
�. 5 ��� ._�_C.Q
� __J _ .
cc :
�.���s �1-��9�_ _��__N _ > _
_ _ .5�1�'S �$ -��1(� _ � � o
_ a• 51��e�-#-_ ��_ _ _ _ � _ �_ _� _ _ _
_ � l. S 1��P1_t.-�s A� l�---� ��� ,� o
o _ _ F-- _
_ _ 1�.• 51�� S_ � 1 __ _ _ _
f_ ___ _ _ _ _-- _- _ __ ._ ___ _.
_ � _ _ ___ _ _ _ _ _ _ _
_ _ _ __ _ . __ _ _ _ __ _ _ _ _ _
___ _ _ __ . _ _ _ _
_ _ _ _:
**********************s*********************************************************************
TOWN OF VAIL, COLORADO Statement
********************************s****s******************************************************
Statement Number: R060000463 Amount: $5,009.88 04/27/200609:45 AM
Payment Method: Check Init: JS
Notation: 1526/JOHN
PURCHASE
-----------------------------------------------------------------------------
Permit No: B06-0100 Type: NEW (SFR,P/S,DUP) PERMIT
Parcel No: 2101-122-0100-9
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE
Total Fees: $12,720.38
This Payment: $5,009.88 Total ALL Pmts: $5,009.88
Balance: $7,710.50
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code
--------------------
PF 00100003112300
Description Current Pmts
------------------------------ ------------
PI,AN CHECK FEES 5, 009.88
-----------------------------------------------------------------------------
�
r' r 'i
Questions? Call the Building Team at 479-2325
Bui/ding Permit Submitta/ Check/ist
Department of Community Development
Project Name: ������ oU��
Project Address•
�-H ��',ol 1� � l�aa,�:l . CA s1 b S�
. �
✓ This Check/ist must be comv/eted befiore a Bui/dino Permit aon/ication is
c t�e .
All pages of application is complete �+ , K
�Has DRB approval obtained (if required) Provide a copy of approval form C��r L�'�' _` �
❑ Plan Check Fee required at submittal for projects valued over $100,000.00 (see attached fee
schedule)
� Complete site plan submitted
�i Public Way Permit application included if applicable (refer to Public Works checklist)
❑ Staging plan included (refer to Public Works checklist) No dumuster narkina or material storaae
allowed on roadwavs and shoulders without written auuroval
,� Asbestos test and results submitted if demolition is occurring
�Architect stamp and signature (All Commercial and Multi family)
Full floor plans including building sections and elevations(3 sets for remodels, 4 sets of plans for SFR
and Duplex, 5 sets of plans for Multi-Family and Commercial Buildings)
� Window and door schedule
�Full structural plans, including design criteria (i.e.loads)
� Structural Engineer stamp and signature on structural plans (All Commercial and Multi Family)
�Soils Report must be submitted prior to footing inspection _______
re resistive ass�mblies specified and penetrations indicated -� 6� p��-s
`� Smoke detectors shown on plans On Q��->
� Types and quantity of fireplaces shown Q v� P��,� -
ApplicanYs Signature: • /
Date of submittal:
Received By:
I�
F:\cdev\FORMS\Permits\Building\building�ermit.DOC Page 2 of 16 02/09/2005
� Design Review Board
� ACTION FORM
Department of Community Development
TOWN OF VAIL 75 South Frontage Road, Vail, Colorado 81657
te1:970.479.2139 fax:970.479.2452
web: www.ci.vail.co.us
Project Name: PURCHASE NEW P/S RESIDENCE DRB Number: DRB050445
Project Description:
FINAL APPROVAL FOR NEW CON5TRUCTION OF PRIMARY/SECONDARY RESIDENCE; all
specifications inlcuded in file
Participants:
OWNER PURCHASE, JOHN LAYTON 08/26/2005 Phone: 970-949-4121
754 E POTATO PATCH DR
VAIL
CO 81657
APPLICANT STEVEN JAMES RIDEN, AIA ARCH08/26/2005
PO BOX 3238
VAIL
CO 81658
License: C000001738
Project Address: 4418 COLUMBINE DR VAIL
4418 COLUMBINE DRIVE
Phone:949-4121
Location:
Legal Description: Lot: 3 Block: Subdivision: BIGHORN 3RD ADDITION
Parcel Number: 2101-122-0100-9
Comments: see conditions
Motion By: Dorward
Second By: Friztlen
Vote: 4-0-0
Conditions:
BOARD/STAFF ACTION
Action: APPROVED
Date of Approval: 09/21/2005
Cond: 8
(PLAN): No changes to these plans may be made without the written consent of Town of
Vail staff and/or the appropriate review committee(s).
Cond: 0
(PLAN): DRB approval does not constitute a permit for building. Please consult with
Town of Vail Building personnel prior to construction activities.
Cond:201
DRB approval shall not become valid for 20 days following the date of approval.
Cond:202
Approval of this project shall lapse and become void one (1) year following the date
of final approval, unless a building permit is issued and construction is commenced
and is diligently pursued toward completion.
Cond: CON0007569
At the time of building permit submittal, the applicant shall submit a wet-stamped
survey of the lot.
Entry: 09/22/2005 By: ee Action: AP
Cond: CON0007570
At the time of building permit submittal, the applicant shall have fulfilled the
requirements of the site specific geologic investigation pursuant to Section
12-21-15-B, Vail Town Code.
Cond: CON0007571
At the time of building permit submittal, the applicant shall provide the Community
Development Department with all utility signatures.
Entry: 09/22/2005 By: ee Action: AP
Cond: CON0007572
At the time of building permit submittal, the applicant shall submit to the Town of
Vail professionally-engineered and stamped drawings of all walls on the site that
are tiered and/or over four feet (4') in height.
Cond: CON0007573
Prior to the time of building permit submittal, the applicant shall return to the
Design Review Board with a revised landscape plan and a revised site plan.
Planner: Elisabeth Eckel DRB Fee Paid: $650.00
SEP-� t�.,1U. 1UU5 ;1�1:21 NM�
,. Sep-ZQ 20D6 09:U0 FrodrERWSD
. . .
HULY CRUSS ENEKGY_N AIA FAX No. 9709490304 NU
970a764�89 T�609
P- 002
p.00?Joo2 F—o4d
. �1 ~ ..�� �.
� �
U7`ILITY•ApPROVAL � V�RIFICATION.
This 1`orm serves to ve[lfy that ihe propased improvements will noT impacc any oxisdng or propased atility services,
and also io varifjr serv�ce avallablity+ �ana loc�tion tor new ccnsVuction end sho �Id b� used i�n� nJU n� �d`^� tions�
prepanng your utilky pl�n and scheduling histel(etions. A srte plan, inciuding g din9 P p�
sha0 be submltted to 'd�e followi�tg utl�ttles fcr approval and verificatlon.
uthorze
Si4na�
Co 0
ate
awESr
970.384_0257(fax) �
Contacts: �
Sc�tt Carrington 970.466.6860 �� ��
Jason 5harp 970.384,0238 "
�cCEL HiGH PRESStJR� Ga
970.262_4076 (tel)
Corttacr_ Rich Sisneros
HCLY CR055 �'Y
970.9;9,5892 (tAJ)
970_9�49.4566 (fax)
Co(tcacC �}
pccEL �N�RGY
97o.26Z.4038 (fax)
C.0(1LaCl5:
Kit Bogart 9T0_262,a024.
Jim O'neal 970.262.�03
�� R�vER warEa �
snrr�rA'r1o1� �isxEticY
970.476_7460 (tel)
970_476.4089 (fax)
Corttact: Fred Wasle�e
� COMC.nsr CABLE
9T0,949.122� X 112 tt�l)
s�a.�9_sisa �iax�
Ccrttact Floyd Salazar
�—
/b�`'�� �f (v►+af i P�5' � n � q=7O '�S
� _ -
. !/�w °�-y �vu-c�
G� �
�� � � ' �
�..,� '
' �4�IF i' ✓�C p« ('b55 Eti�✓'GtnC.F
c'r Gul -�-St.G _ �oG4.�t{���Gf �
N07�S:
1, If the utlllty approval & ver�tlr.a�don form has signatur�s from each af the utllity companies, and no cammems are
madv directly on the form, the Town wilf presume that chere are na pmb►ems and the devetopmerrt can proceed.
2!f a utili[y company has concems with' �the proposed construc�ion, t�e uttllty representa'eve shall nate dirocdy on
tne Uti(Ity ver�fication form that there is a prohlem whlcf� needs to 6e resolved. The issue should then be detailed in
an atrached letter io the 7own of Vail, Howev$r, please� keep in mind that iL is the resportsibifity af t�►e ucl�lty
campany and the applicant to resolve idendFled problems,
3. These verific.�tlons do not relieve the contrz�otc�r of the responsibili4y to obtain a Public Way�Permit from the
� �ocations must bp nbt�ined befo�e di aq lnq In any pubtic right-: ;
Department of Pub11c Works at ihe Town of un�h���hQ, DBrmiil� n4t a Public WaY ry��rn�t An�L1 M�IS'[ D2 ODT2i►IRd !
o�way or pasem�t witilin the 7own Gf Vail.
se ar �I . �
1'he Developer Is required and agrees to supmlt any revlsod dc�wings to �he udlltles inr re-approval & re�verificaUon if
the 5ubmltted plans are akered in �ny W�Y e�'�� �e at,►�horized �ignawre date (unle�s othErw�se sPeclfl'���Y not�d
within the comment area af this form).
De�►elopers SJg�alure – Date
P�qe 8 of 12/04/01/0�
SEP—i�tr, 1U 1UU5 (11:45NM�
�
tNtKGY;N AIA FAX No.
9709490304 NU. j�j
r, 1 �- uu�
` , ' l.;�C'' � , ��l�Iv�. � � � �� ��a � t�'c"tr� �l
.
� � 4��� ������� ����� . , ,
'f IL Y �APPROVAI, & VERIF ICATION
This fvrm sen�es to vsrliy that the propossd imprcvemerits will not itnpact eny existing or prvposed utility servlces,
and also to veriry service availabil?ry and focation for new constructidn and should be used in corrjunction with
prsparingyouur util"rty plan and scheduling install�tlons. A sits plan, including grading plan, floor plan, and elevations,
shall be submitted to the following u#ilit(es for approvel ehd verificatio�.
Autharized
! S'anature
'�4VVEST
970.334_0257(fa�c)
Contacts:
Scott Carrington 970.468,6360
Jeson Sharp 970_384.0238
EXCEL H(GH PRES5LIR� GAS �
970.2624076 (tel)
Cor�tact; Rich Sisneros
HOLY CROSS FI.ECTRIC
9y0.949�5892 (tel)
970.9a9.a566 (Pax)
Contact: Ted Husky
FXCEL ENERGY
970.262.4038 (fax)
CqrrlaCts:
IGt Bogart 970.262,�102d
J'un 0'neal 970.262.4D03
OA�EAGL� RIVER WATER �
saNi7ATION DISiRICT
970.476,7480 (tel)
970_476_d089 (fax)
Corrta�t: Fred Haslee
VGOMCAS7 CABLE
970.949_1224 x 1'(2 (tel)
97�.949.9138 (fa�t)
Conract Royd Sal�ar
�un• �
Date
___,�.f�_1 �'l O Gd� �e � 0 QS"�
C2��
, �
_�
NOT�S� �
1_ If the utility approval & verifica6on fonn has signatures from each of the utility companies, and no comments are
made dirsctly on the form, the Town will presume ihat ther'e are no problems and the development can proceed,
2_ If a udliry company has concems with the proposed construction, tfio �tility rspresentative shall noae direcNy on
the utility verific2tion torm that there is a problem which needs to be resolved, �The issue should then be detailed in
an attached letter to the Town of Vail. However, please keep in mind that it is the r�sponsibility of the utili'ry
company and the applicarlt to resol�e jdentiFed problems.
3. These verifications do not relieve the contractor of the respohsibfliry to oblain a Public Way Permit from the
Department of PUblic Worfcs at the Town of Vail. Utili Iocations must j��q�tain�d before dic�aina in any publi� �ight-
of-way or easement within the Tvwn of Vafl. A ui�dln�perml ,,,[S not a Public WaXpermit and mu5t be o� ine�
�aratelv '
The Developer is required and agrees to 6ubmit any I�evised drdwing5 to the utilities for re-approval 8� re-verific2tion if
the subrnitted plans are altefetl in any way after the authorized slgnatUre date (unless atherwise specifically nvted
wir,►,in the comment area of thls formj. .
peuelopers Signature bat�
Page 8 of 12/Oa/01 /04
5tN �4� ' 4�5 15
SEP-19-�00� �ION DQ:l6 PM
Fh' XC;tL tlVttiliY
51E�E JA�IES �ICEN AIA
'�'(b �b� 41�,5t3 I U �i1y'(b'�4�.34�4
FAX No. y 111y4yUJU4
b�
r. uu�
,..
, � Ldr 7j � �1(���� �c.� �:✓ � +e.� �� � rt''�ra�t
4� �� ��1TIL Y APPROV,qL S VE �I�F CAV �
Tnis form se�ves to ve�ify that tne proposed impro�ements wi11 not impact any ex�sting or proposed utilily services.
and also to verify service availability and location for new construCtion and should be used in conjunctio� wlth
prsParing.your utility plan and scheduling installalions. A site p�an, including grading p�an, tioor plsn, and etevat;ons.
shall be submitted to the following utilities for approval and verifica�ion.
`�pwEST
970.38d.0257(fax)
ConlaCts:
Scoti Carrington 970.468,6860
Jason Sharp 970.3Ba.oZ38
EXCEL HIGH PRESSURE GAS
970,262 a076 (10l)
Co�lact: Rich S�sneroS
✓HOLY CR055 ELECTI2IC
elo.sas.ses2 (tei)
970,949.a566 (Pax)
Contact� Ted Husky
EXCEI. �NERGY
97U262.a038 (tax)
contacts�
Kit Bogart 970.262.d024
Jm O'neal 970.262.a003
ciEAGLE RIV�'R WATER 8
SANITATION DISTRICT
970.a76 7480 (te1)
970.476.4089 (fax)
Conlact; Fred Hasles
�/CQMCAST CABLE
970.9d9.1224 x 112 (tel)
970.9499138 (fax)
Contact: Floyd Sala¢ar
Author�zed
I nature
1 � �
. �.�
,f,omments Aate
����
`� - Z a •,�
NOTES �
1, If the utility approval & verification form has signatu►es Nom each ot the �tllily companies, a�d na commenls are
made d�rectly on the fnrm, the Town will p�esume that there are no problems and the development can proceed.
2. ff a ulility company has c�ncems w�th the propose0 cvnstruction, the ufility representative shall note direufy on
the utifity venfication farm that the�e is a problem wh�ch needs to be resowed. 7'he issue should lhen be detailed in
an aitached ietter to the Town of Vail. However, please keep i� mind that It Is the respons�bility of 'the utility
company and the app��cani to resolve identi(ied problems.
3. 7hese verification5 do not relieve the contraclor of the fesponsibility to obtain a Public Way Permit trom lhe
Oepartment of Public Works at the Town oF Vad. Utihtv locations must be obta�ned beiore diaainca, in any pubtic right-
of•�+ay or easemant within the Town ot Va�l A buildma aermit �s �01 a vubtic W�y p�rrt�jt and must be obl�lned
�aratei; '
The Devebper �s required end egrees co submit any revised drawings to the utiiities for �e-approval � re-verificalion �f
t�e supmltled plans are aitered in any way alter the authorized slgnature date (unless otherwise Specificatly noted
wilh�i� the comment area of tnis form)
Devebper's Signature Date ,
Page 8 oI 12/Oa/01 /04
** TOTAL PRGE.02 **
' O'Brien and Associates, LLC
-' Gonsulting Geological and Geotechnical Services
— May 26, 2005
Mr. .iohn Purchase
Purchase Development, LLC
754 E. Potafo Patch Drive
Vail, Colorado 81657
Re; SiEe Specific Geologic �vestigation For Proposed Duplex Residence on Lot 3,
A r+esubd'nrision of part of Bighorn Subdivision, Third Addition, Amended Plat,
Town of Vail, Eagte County, Colorado
On Friday May 13, 2003 a geologic reoonnaissance survey of the property
located at 4418 Columbine Drive was per#amed. It was determi�ed that the 0.7� acre
site is underlain by Glacial Drift that was deposited as part of a m�ch larger Lateral
Moraine up the BigE�om Creek Drainage. The majority of the site siopes to the northwest
at a grade of beNveen 15 and 30 percent, some af the slopes higher up and outside of
the building footprint contain grades in excess of 30 �ercent. A portion of these higher
slope areas has been ider�tified as a geologically sensitive area, having a moderate
rockfal� hazard, as shown in Figure 1. During this and a subsequent visit on Friday the
13"' of May, n si ns o ckfall wer encoun#er The Glacial Drift is composed
of very large to small, rounded- to we rounded, oulder and cobble sized clasts af
Precambrian aged granitic rock in a silty sand matrix as shown in Fgure 2, these gran�ic
ror,lcs crop art higher up the Bighom Drainage and in t�e Gore Range. The exposed
surFaoes of the surfECial clasts were weathered, moss oovered, and held in place by the
forest mat ind�cating no recent large-scale movernent In some localized steeper areas
soil creep was evidenced by pistol butted trees and some srr�all scale slumping. The
permeability and ir�fiitration rate for glacial materials is generally high artd therefore tt�e
water table is probably seasonally high and near the surface, causing localized small-
scale slope instability. Small-scale instabilities are common on any slope of this nature
that is actively being eroded. At the base oi the slope where the property meets the
road, some cobble-sized clasts of granite had been recently eroded from the road cut for
tfie cul-de-sac.
On the May '!3m visit, a ten foat deep test pit was excavated within the proposed
building t�ootprint as shown in Figures 1 and 3. Bedrock was not encountered and this
deposit of glacial till may be several tens of feet thidc, although excavation was difficult,
cuts up to 10-Feet �n depth should be achievable with the proper equipment. A preferred
design technique for glacier deposits is to follow the nabural grade by stepping the �
stnacture down the hillside. There is little soil cover but there is a 6- to 1Qinch tfiick
organic forest mat cove�ing the hurnmodry topography, this material is not suitable for
any load bearing surface and should be removed from within the building footprirrt and
used for land�aping or some other non-structural use. Large boulders should be
removed from the surface upon which the foundation will rest, this surface will also need
to be c�ompacbed wi#h a vibratory compactor, the degree of compaction will be
determined in a subsequerrt Soil & Foundation Report where the maximum dry �it
weight will be determined and discussed along with seepage cor�trol.
The foundation stabiiity for this material is generally good below the frost heave zone. It
is recommended that all load beanng walls or Footers be s t a m_mum of four feet
below the ground surface. Vertiql cuts in this material may stand for several months
1845 West Gore Creek Drive
Vail, CQlorado 81657
Pho ne/Fa x: 970. 4 T9-B212
Email: jpob 1 a. msn,c;om
6�d 6�60-9L�-OL6-6 aseyo�nd �69�80 90 6Z daS
' O'Brien and Associates, LLC
•` Consu�ting Geologica! and Geotechnical Services
— but will ravel and slump on wetting and drying over several seasons, the angle of repose
for this material is about 35 degrees. The sloae stability of this glacPal material is
moderate, as it is generally unconsolidated and may slide on moderate to steep slopes if
it beoomes water saturated. To help prevent this, any over-excavations, areas where
slabs will �be poured. or bad�illed areas adjacent to foundations should be ba�lfed with
appropriate fifl, moisture treated to within �3 peroent of tt�e optimurn water content and
compacted to at least 95 peroent of the dry unit weight. Additionally, since water table
fluctuations are unknown, and to aid in the control of possible liquefaction and pipirtg,
foundati+�n drainage should incorporate a positive cutoff trench or drain along and below
grade of the foundation walfs. The trench should be lined with a polyethylene moisture
barrier attached to the foundation wall at least two feet up and extentling under the drain.
The drain should be constructed with a 4inch or greater diameter perForated pipe
encased in ai least 16 inches of free draining gravel and a manufac�ured wall drain. The
drain should be sloped so that water flows bo a sump or positive gravity outfet Slopes
around all excavated featur�es should be graded so that positi�re drainage is rnaintained
away from these features at all times.
In order to mi�gate the adjacer�t moderate roc�efall hazard, which would most
likeiy result in a rare cobble or small sized boulder rofling down the slope, the building
fo rirrt should over-excav a ropriate deptl� f istance of ten to
een feet on the hifl si of the structure to prov� e a rockfaA �rotection or rocl�aU
' ch zone behind the ouse. Further, the ins abon o ysica barriers aroun
winera e areas is recamme ed to prevent rock impact Stabilization measures such
as scaling ot the remova! �f unstable rock, cribbing, or the instalfation af retaining walls
may also be utifized in the finaE desigt�. Other acoepteri methods for slowing or diverti�g
falling or bumbling rocks incl�de rock fences, screens, channeling, dams or other
physical barriers. Depending upon what blends in best, one or more of these rockfafl
prevention methods should be employed in your final design.
This investigation has revealed ihat tlle proposed structur�e location �the test pit
area shown on Figure 1} is not in a geologically sensitive area, but it is adjacent to an
area with a moderate rockfall hazard. Therefore sorne moderate rockfall �nitigation
measures should be implemented in the Fnal design to protect the structure from any
errant inskabilities. Further, as I understand the conceptual design, the constructio� of
the proposed stn�dure will r�ot increase any hazarc! t� other property, strucbures, rights
of way, streets or other properties of any kind.
I hope all fhis helps out with your design plans, let me knaw if 1 can be of
assistance with yaur Development Plan or Building Permit. At some point I wou�d like to
review your plans, as you may need my approval and certificatior� that appropriate
mitigation measures have been implemented to get your certificate of occupancy.
O'Brien & Associates, LLC
James P. O'Brien CPG, PG
?845 West Gore Creek Drive
Vail, Golorado 61657
Phon elFax: 970.479-6212
Ema.il: j�ob_I(a�.msn.com
Z'd 6�60-9Lt~OL6-1 eseyoand e69�80 90 6Z daS
' O'Brien and Associates, LLC
.` Cansu�ting Geologica! and Geotechnical Services
Figure 2.
Glacial Driff, large to smal�, rounded- to well-rounded,
Boulder and cobbie sized dasts of Pr�cambrian aged
Granitic rock in a silty sand matrix
1845 Wes# Gore Creek Drn�
Vail, Colorado 81657
Phone/Fax_ 970.479-8212
�mail: jpobin.msn_com
£'d 6b10-9L�-OL6-6 esey�and e00�60 90 6Z daS
O'Brien and Associates, L�C
Consufting Geological and Geotechnical Services
Fgure 3.
Glacial Drift
As e�osed in the test pit
1845 West Gore Creek Drive
Vail, Colorado 8t65T
Pi�onelFax: 970.47�-8212
Email: inobin.msn.com
�'d 6�1Q-9Lti-OL6-L aseyoand �00�60 90 6Z daS
04l07/2666 '10:58 9799269089 LKP ENGINEERING INC PAGE 02
I.�IfP E�agineering, Inc.
C[vIL/G�OTECHNICAT.
Ap�i17, 2006
Mr. Joh� Purchase RE: Boatder Wa�l Detaits
Pnrchase Aevetopment Lot 3, Bxghorn Third Addition
P-O. Box 1391 4418 Co�umbine Drive
Vail, CO 81658 Towzz o� Vai�l, Ea�le County, Colorado
Project No. 06005
Dear John:
At the request from Todd with Steve Riden ,A�cchitect, we have rev�ewed the bouldez
walls on the site plan for the Pzoposed Residence, on Lot 3, Bighorra Thizd Addition, 44 � 8
Columbin,e Dzzve, T'own o;f Vauil, Eagle County, Colorado. The bou�der walls are retaizuz�g mostly
the slope between the south side of the proposed z�esidence and the s�ope above, and between the
north side o�tl�e residence and tb,e adjacent slo�e. �dividual segments o�the boulder wall range
in height �rom zero to 6 feet. Soz�ae of the walls have a lower and an uppez layer.
We have �repared two deta.ils. One is :foz a sit�le layer wall, and one for a double layer
wall. For the two t�er boulder retai.ning wa11s, we recommend tk�at the taller wal�s be on the
bottom of the hillside axxd the shorter walls vzz top. Both designs az�e subject to vez�fication of the
so� a.c�d ground watez cond�ition at the time o� construction.
If you have any questions, please do not hesitate to ca��.
Sincerely,
LKP Engiaaeerang, Inc.
r �, ��ti
Luiza Petrovska, P.E.
Presidez�t
�z�closure
Cc: Steve Riden, A�.A. at fax #970-949-0304, origitxal z�zailed
J�1Wp L2-I,KP\06005BWp�T.wpd
P.O. Bo� 2837, Edwarde, CO 8�632, (970) 926-9088 Te1, (970) 926-9089 Fax
04/07J2006 1e:58
. .
.
9i69269089
LKN �NG1Nttk1NV 1NL
BO ULDER RETAINING WALL
FOR ALL WALLS UP TO fi FEET HIGH
6 inox
1'
�
NOTFS.•
Drolnoge swo%
.i ff
6"
f2'�I
Compocfed bockfi/l
lmper►�ous Bockfill
,' Granular, perv/ous bockflll.
depending on s/te cond/flons
Filter Fab�ic, MJrof/ 140N
or equivo/en!
Perimeter drofn location
ond detoi/, depend/ng on
soi7 and ground wafer
conditlons o! �/me of construction
r�Ut e�
1. THE BOULDER RETA/NJNG WALL SH..4CCL BE CONSTRUCTEO WITH BOULDERS GRE�I TER THAN 1
F£ET. FOR ORY STACK WALLSy 7HE ROCKS W1LL HII VF AS MUCH FLAT SURFACE AREA AS
POSS/BLE', TtJ INCRE�I SE 1HE f7P1C710N SURFACE BETWL�'EN THE BOULDERS.
2. THE BOTTt�M BOULOERS SHALL BE THE URGEST ANp SHALL BE PLAC£D ON NAT112r,
UND/STURBED SD/L, fREE FROM TOPSO/L �IND ORGANICS, QR ON COMPACTL�O STRUC7URAL fl'LL,
�PPROVFD BY THE £NGINEER.
J. TNE SUCCESS/VF BOULOER LAYERS SHA,LL BE OFFSET HORIZONTALLY BY A A,I/NIMUM OF S/X
INCHES FDR EACH VER 11CAL FOOT.
4. A MlN/MUM 0� ON£ FOOT OF UND/STURBED SOIL COVF'R SHALL BE PROVIDED /N FRONT OF THE
WALL.
5 THE COMPACTION OF iHE SOIL BACKFILL SHOULO BE 1£STFD BY TNE ENG/Nf£R OR !T CAN BE
BACKFILLED W17N CLEAN, CRUSHED ROCK.
6 THE ABOVE DES/GN M!/ST BE RENEWED, AND THE CONSTRUCIlON OF THE BOULDER WALL
INSPEC lE"D, BY TNE DES/GN£R Af 1FR VL`�Rlf7CIl TION OF 7N£ SO/L AND GROiI/ND Wil TER WA TFR
CONO/110NS A T 7N£ I7ME OF CONSTRUCTION.
cmi/osoTac�cm.
.LKP Engin e erin,g, In c.
P,O. Box T937 Edword�, CO 91B32
t� (9�0) oze-qoee ia. (o�a) ezs-ooea
SINGLE BOULDER RETAINING IIALL
�" 06005
cor ,� era�aww n►uto ��anaw
�re cau�NEORI►�E �"`� N.T.S.
TONN QF VAJ4 £AC1E COINd fY, CALARMO -- •°-- --
1
b4Jnf/lbbb 1b:5�
• �
N07F5•
y f by'Lb�b�y
BD ULI�ER
FOR
6'
r
LKI-' tNUlIYttK11VU 11V1.,
RETAINING WALL
TWO TIER WALLS
2
1 �_�-
6'
(
12' �
Z' to 6'
4' min.
Z �
1 n
, COA/PACTED,
GRANULAR BACKf7LL.
SFE NOTE �5
J PER/METFR DRA/N LOCA JION
AND OETi4/L, DEPENDING ON
SO/L AND GROUND Wi4 TER
cavarnavs
rr�uc r�v
/NSTALL F1L T£R FABR/C
(M/RAF/ 140N OR
EOU/VALENT) BEH/ND THE
BOl/LD£RS
1. THE BOULDER R£TA/N/NG WALL SHALL BE CONSTRUCTFD Wl1H BOULDERS GREA 1FR 1NAN 2
FEET. FOR ORY STACK W�ILLS, THE ROCKS N7LL HAVF AS MUCH FLAT. SURFAC£ AREII AS
POSS/BLE, TD /NCREASE TNE FR/C AON SURfACE BETWFEN TNE BOULD£RS.
Z. THE BOTTOM BOULO£RS SHALL BE 1HE LARG£ST AND SHALL BE PLACED ON NA 17VF
UND/STURBED SOIL, FREE FROM TOPSOIL AND ORGIIN/CS, OR ON COMPACTED STRUCILRAL FJLL,
APPROVED BY THE ENGYN£ER.
.J 7HE SUCCESSlVF BDULDER LA YERS SH.ILL B£ OFFSET HOR/ZONTALL Y BY A M/N/MUM OF S/X
INCHES FOR EACH VFRACAL FOOT.
4. A M/N/MUA,/ OF ONE FOOT OF UND/STURB£D SO/L COV�R SHALL BE PRONDED /N FRONT OF THE
WALC_
5. THE COMPACT/0N OF TN£ SO/L BACKF/l1 SHOULD BE 7F'S7E0 BY THE ENG/NEER OR /T CAN BE
BACKF/L�£D Wl TH CLEAN, CRUSHED ROCK,
6. THE ABOVF DES/GN MUST BE R£NEWED, AND THE CONSTRUC7l'ON OF 7NE BOULDER WALL
INSPECTED, BY THE DES/GNER AFT£R VL'R/F/CA 170N OF TNE SO/L AND ' C.ROIlND WA TL�R WA TER
COND/710NS AT 7HE 71M£ OF GONSTRUC770N.
crva/aso�ractt[�uc�.
LKP Engin eering, In c.
P.O. Box 2637 Ed�d�, CO 81832
t�l (970) 928—pOB9 iax (970) 826-9Q8�
?7Y0 TIER �pULDER RETAINING 1IALL
�� N�" 06005
LOT J BlGMpR/V 1HlRO A001 AAN
�sta cauw�nrE arire � N. T.S
TONN A� ViV!„ £A[Yf CWNT►; CQLQRADG
�
APR-26-2006 WED 02;09 PM STEVE JAMES RIDEN AIA
Sep��xi-D5 11;44am From-TOWN OF VAIL COMNUNITY DEV�LOPNENT
. ,
� . ' �_
FAX No. 9709490304 P,002
9T04r8245z T-756 P.002/005 F-8t5 '
T�WNOFYAILV � -
Department of Comm.unity Developrnent
7S South Fmntage �oad �
Yair, Colorado 8165.� .
970�f79 Z138
FAX 9T0-479-2�F52 '
www.vailgw.com
September 72, 2005
Mr_ Steve Riden, AtA
Steven James Riden Architect PC
PO Box 3238
Vail, CO 81658�23H
(fa�c) 970.949.0304
Re: 441B Columbine D�iveJLot 3, Bigham Subdivision
, Fin'sl relvaw of a new two-family resid�nce
DRB05-0445
Dear Steve,
Thank you, and Todd� for attending yesterdays Design Review Board hearing of a final review of the
Purchase residence at the aforementioned address. The model that was made was'very helpfu! �For the Bnard
in "reading" the sibe and the situation of the residence upon it. As you know, the Design Review Boa�d
unanimously approved the project with the following conditions:
�1. At the time of 6uilding permit submiftal, the applicarrt shall submif a wet siamped survey of
the lot. •
� Z. Af the time of bu�ldlqg permif submittal, the applica�rE shall have fulfl/led tJte
requirements of the site speclt% geolo8ic investigation pursuant tv Section 4a 29-15-
B, Vail Town Code �
�3. At fhe �me of6u�yding permit submittal, the applicant shall provide the Commun�y
Developmen� Department with all utility signstur�s ,
�4. Af the time of building permit su6mittal, th� applicarnt shall submit to the Town o�
VaII professivnaUy-engin�ered and stamped drawirLqs of a// walls on the siie fhat ar�
tiened and/or aver four feet (4') in height
5. Prier !o fhe time of bu1lding permit submiftal, the appllcant sha/! return !o the
Design Review Board with a r+evised landscape pfan and a revised si�e plan.'
,
Thank you for fulfilling th� first and thfrd conditions at yesterday's meeting through the submittal oi the
stamped survey and the utility s�qnaiures. 1 have i�dicated in the wmputer that these conditions no (ongaP
need to be fulfifled. '
Regarding the fifth condition, the Board felt the need to see a more detailed landsppe plan signifying
vegetation that wUl thrive on the site While appropriatety mitigating the cut areas. Th� suggastion was m�de
that the walis tio the rear of the residence could be increased in height (up to six feet) if that change better
allowed for the possibility that landscaping or sod would �urvive in that area of the �sit� The Board requested
that the revised site plan indicate more accurately the treatment af drainage on the site.
*�� nScrcY,Y.0 p�Ip/sA
APR-26-2006 WED 02:09 PM STEVE JAMES RIDEN AIA FAX No. 9109490304 P.003
Sep �Z�DS 11�44am From-TOWN OF VAIL CONMUNITY DEVELOPMENT 97D4r8245z T-756 P.003/005 F-815
. ,, , '
, . �
Pie�ase route the revised la�dscape and site plans to me at leest twa weeks before the meeting at which you
would like to be heard. The next three Design Review Bnard meetings will occur on October 12, October 19,
and November 2. I will be out of the office for both crf the October meeti�gs, but if that tlmellne works best for
you, another planner would be more than wiiling to preserrt the revised plans, • .
tF�e approval form stating the conditions of approvai for your records. �eel frae to contact rne
ng qusstions. I vi' I plan to receive revised plans irom you soon.
E�abeth Eckel
970.4792454
endosure
0
04/18l2007 13:16 9709269089
� T,KF Engineering, Inc.
C�V �./G��'f'���NICAI.
,a�r�� � s, 200�
Mr. JOb�. �urehaSe
Purchase Deve�vpm,emt
�'.O. Box �908
Eagle, CQ 8�63a,
Via Fa�: 970-328-U952
Dear Jol�zr.:
RECEIVED 04/18/2007 02:08
LKP ENGINEERING INC PAGE 01
To�v� of Vail
�� �
���s� �
� Y
�.:.� �. .:_�_���
R.E: Opem �o�e Observat�o�
Lot 3, Bxgbtorn, 3"� Addxt�on
44�.8 Colu�ubxz�e Dt-�ve
Towm v:f Va�l
�agle Cau�uty, Co�arado
ProjectNo. �6005
� � , � �/,
�
,A,t your request, on April 17, 2007, we visited the construction sxte at �,ot 3, Bzg,l�.ozzi., 3`a
A,ddit�on, A�418 Columbin� Drive, Town of Vail, Eagle Caunty, Colo�rado. Tlae puzpose of ou.r
site vis�t was to observe the soils �xposed in the foundation excavatxqxt an,d cozx�paz�e thezxa witla
tk�e �dx�gs az�.d recvnazx�ez�dat�oz�s o£the Soi1 and Foundatian Investigation Re�vzt, uz�dez� the
same P:roject Nwrz�bez, dated �'eb�cuazy X5, 2006.
'�k�e e�cavataon co�.sxsted o�bench.es and trenehes st�p�ing into the s�te. '�'k�e excavatzoz�
euts, ranged itozxa 4£eet to about 40 �eet. 'Z'k�e so�� exposed in the foundation excava�i.oz�, was
consistent with the. jindings and recommendations of the above-named soil :s report. �t co�s�sted
af light bzow�, s�dy gzavel wi�tb, cobbl.es and bould�rs. 7'he exposed soil is suitahle for the
recommended ,coil. bearing pressure of 3000 �sf The ba2tom of tk�e e�cavatxon was com�acted.
No soft s�aots were reported.
We recozxun,�e�,d co�oc�pliazace with the recommendation.s af'tk�e above-�nazlaed soil report
during the ze�axndez� o�tk�e coz�stxuetion, s�eeiiieal�y wit�, tk�e sect-�o�s on. d.rainage, grading a�ad
irrigation.
If you have any q,uestxons, p�ease do not hesitate to call.
Sxncerely,
��P EnginE
l�
uxza Petrov
Preszdez�t �
J:1WP I 2-LKP12Q06\OC�O(15open.wpd
P.O. Box 2$37, �dwa�ds, CO 81632, (970) 92b-9088 T'el, (97Q) 926-90$9 Fax
w�
�
����� �
v� 4 • Q `-'
� t
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNEDO
Buildin Permit #: D � � + � t �
��i19rp�0�
TO TOWN OF VAIL BUILDING PERMIT
, __� are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vaii, Colorado 81657
'""'`All Revision submittals must include the Field Set of approved plans. No further insaections
will be preformed until the revisions are aaaroved. ***
CONTRACTOR INFORMATION
COMPLETE
For Pancel # Contact Eagle County Assessors O�ce at 970-328-8640 or visit www.eaple-countv.com
(Zo `0 � ��
Job Name: ��C � LDwnti�(nJ� Q✓Z� c/L' � Job Address: 4.%�.� g������ �� � 1��
Legal Description Lot: Block:
Owners Name: 3� � Pr Q,�,�y�' A�
Architect/Designer: 5.�� ��� A�
Engineer: 5'9S � I�G . A�
Filing: Subdivision: g1l�'Ho2.�1 ���p�-
, �� Bax �ao g, Phone: 32g —�. ZZ�
� A o x 323 � v�� , c o Ph0
� bo,c � �1 � , P�� � c.0 Pha
= S'f ���u� nG�oA�� � ���t i a�
�IT
-�/2i
Work Class: New (/) Addition ( ) Remodel ( ) Repair ( ) Demo ( ) Other ( )
Work Type: Interior Exterior () Both () Does an EHU exist at this location: Yes () No ()
Type of Bldg.: Single-family () Two-famil ) Multi-family () Commercial () Restaurant () Other () P/ s
No. of Existing Dwelling Units in this building: (� No. of Accommodation Units in this building: p
of
s
of
a
Gas
Gas
a
FOR OFFICE USE ONL'
Wood
�
Wood
F:lcdevlFORMS�Perrnits�Building�building_revision_11-23-2005.doc
Page 1 of 2
12/8/2005
n
. I u t i o n s
J
N G I N E E R I N G
P.O. BOX 2494 PROJECT LOT 3, BIGHORN SUB. 3RD. ADD.
AVON. CO 81620
JOB NO. 0208-05
PH 970.949.7100 SHEET NO. SL1 OF
FAX 970.949.3377 JPL �4.2�.�7
CALCULATED BY DATE
SCALE 1 /4" = 1'-0"
..�: R v
L �'±, S, .•. . . E�. R � � ..., s
,�,, �o- !�n!?�,�
� �� g�� . . ` � y�� � L�
�, � , -� + �
:> �a
�
BM. POCKET
I
OF = 8579'- �
CASCADE I
FTG. STEP I
REF SL4
�
CRAWLSPACE
�
7'-���
5'-2�" CLR.
TOW = 8618'-9 3/4
TO = VIF
nF = u��a�-
EDGE OF
SLAB
d �
J
U
� j
� 5�-��
2'-8"
FTG.
STEP
3
S12
I
0
�
TOW = 8619'-9 3/4.
TOL = VIF
TOF = 8579'-8
CASCAD
FTG. STEP
EF SL4
8580'-0
TO SLAB
�
�
�
Z
� �:✓ .
v 0 6!�
FOUNDATION PLAN EAST UNIT
P.o. eox zasa LOT 3, BIGHORN SUB. 3RD. ADD.
AVON. CO 81620 PROJECT
� JOB NO. 0208-05
PH 970.949.7100 SHEET NO. S� OF
FAX 970.949.3377 JPL 04.20.07
CALCULATED BY DATE
� u t i o � s SCALE 1�4�� = 1�-���
N G I N E E R I N G
FOUNDATION PLAN WEST UNIT
n
•lutions
J
N G I N E E R I N G
P.O. BOX 2494
AVON. CO 81620 PROJECT LOT 3, BIGHORN SUB. 3RD. ADD.
JOB NO. 0208-05
PH 970.949.7100 SHEET NO. SL3 OF
FAX 970.949.3377
CALCULATED BY JPL DATE 04.20.07
SCALE 3/4" = 1'-0"
(1)-#4 CONT.
2'-
#5 DWLS. x `_�'
@ 24" O.C. 2' 0
8579'-2
TOF
a a
a
d ° a
o Q
• •
� Q Q . .
d
#5 REBARS @ 12" O.C. �
EA. WAY
-��s—
�
,; I�1
r ����ti
���—��—��—��
�°I:n:n�ri°� u
n.=n=n=n=
11=11=11=
1_�I--:11=11=1f
11=11=11=
11=1[=71:=11
�� ' ^I1.=11=��,-
�� • 1�.�11-11��'1 :
�����r �!. �I�'.
��=.. •�
2x4 OR 2x6 STUD
BRG. WALL
16d DRIVE PINS @ 16" O.C.
(IF SLAB IS HEATED GLUE BOT. f�)
11"THICKENED SLAB EDGE W/
(2)-#5's CONT. HORZ. ,TYP.
4" CONC. SLAB PER PLAN
TO SLAB
0
= 1'-0
�
�
. I u t i o n s
i
N G I N E E R I N G
P.O. BOX 2494
AVON. CO 81620 PROJECT LOT 3, BIGHORN SUB. 3RD. ADD.
JOB NO. 0208-05
PH 970.949.7100 SHEET NO. SL4
FAX 970.949.3377 �F
CALCULATED BY JPL DATE 04.20.07
SCALE NO SCALE
��,�,�z� �11
�
�� II
r�, �
//
��
i o �o
o � �ia
J�� `V O Z O
o x 0 Q ��
N � m � (� � (�
� a- u- U O U
�
�' � OUa �Ua
MAR/27/2008/THU 11;15 AM N4dCCOG FAX No,9704681208 P.001/001
� Northwest Colorado �Counci[ of �orrernmeni� � � -�7^�.-
i � .� . ELEI/AT�R�P��Mi'Y' A�Pl..YC.�4TION T° G
� j �Fom
�--� �,rt � _ ii?�'_D�D . ..:_ au�isat n - �1.� r � � . -
: ' Toial Fee �.��j' . � �Date Paid i t # . ��� �'�-9 �- # of pag�s �
: , P�a�t Reviewed and Approvad bY � �ssu�d _ � -�%oS1 • .
' . . ' P�rmrt bgrlratioa Date 2`?-�` �, .
E . -
�- ** Alt-#he foflowing musr be compivl�d by the etevai�or coetrac�ar ** •, ..
Tnaaca,rats,-itlegibiQ a� mt�sing it�#ormat%ri wili cau�e a delay ia i�e application� praaess. .
;- ; Please complete a sep�rat� appfication pet corrveyance- . .
�
��
r 1
� • • �.
�
i
� , .
i
7urisdictiun Ruildtng Permlt #
Job Adclress ��l l 5� �l711.c �
Owreer �
Mailing Addre.ss � . X $� �Q �
Phone # � �J�� '^ �� ' . .
�iQti/ai�nr Co���or �
Mafling Address �� Z� �r4'in , , %'-YI
Phone # q 7L� r� ��' �� 7� � ,.
��anaL.�i2�.i if��� ` �� � �'l�5 � .
. , r°—
= � CD �l ����. - � �� . .
F�c # � — �, .
�-�-►�L�.�'i�c7i� ' � %
�# a7C� -���-�7.� �-7 . - �
.
t.�tnl��l.�...� s.y,i �.,r �.,......a.e.�.... s��. -�__ �� ,
�,. New L�stallation , urtit ar� Car�tra� #- - - ---- -------
�---. ' Altsratlon [un/t csnnofbe return�d tcr sart�laa u�i!
-�bewor�c �1�,5-(i�11 irl�u) ��.��r�i1 ��:
'A I _�
' --- �,. ,_ R 1i�t�'F� ' ' • -
� � lVOiiCg - � • 1=EES . .
F hereby �tify that I have rsnd and examined t�is �pplication Passenger or f�ight etev�bor, lu�I�, �1a�or, maning walic:
and Iv�aw #he same to be true af�d aotrect. M pro�ions eq' Iaws Up ta and tndL+dinB �50,000 af �►aluatian �$375.00
and atdinar�ces goveming this type aF work v�rtll be mmplied w�th over $50,000 of valuation =$350.00 plus $7.fl0 for ea�i
whether specified herein_or no� i'he grartting aF � p�it does $1,000 UO or fr'adion thtneof over $54,OQp.00 '.
nct pres�.rtne tn gir� au�f.y tio•vblate or cancel the p�otts .
of arty at�ter StdD� al' I�J lativ regulatir�g •c�onstructdon or #he 13f� DumbwaiY�t ar pe4vabe ses�d�roe el�vabor: ,.
rnt�nc�e of consh�ptt. ' . Up �o and indudiny $20,000 of valuetton =�275.00
� �wer �Z0,000 of valualfofi =�50.00 plus $4,0� for each '.
� � $1,QOO.OD ot Trar�iar► t�ereof wer $20,OOD.00 .
• ' MA90R ALTERA7YdN ES•
F�s f+or r�ajor alkeratians �all be as.sat farth in-Tabie �-A of the
Unif�rm AdmbliSFrative Code or Table 1 A,.
vi►�u,arto � , .
�
TOT�LL �E�: • � �� • .. .
�Y� 1 - -�.. _' � _„� ..i^- _ -I._ :
�evafior plan revlew and fiefc! inspe�[ons wiU be conductied by the North�i,nest Gobrado Cauncr7 ofi Governmerns. PfaT1s Will
be fbr�varded t�o NWCCOG f'or review and appebval. S�hr.dule inspedanns by cordading ifie MNOCOG devatar inspedaor at
970-R�8-0295 ext 508. . .
Page 1 of 1
Charlie Davis - 4418 Columbine Dr.
�:�:�:,��.:� � �. � ������,�.�� ���� �..�,�:��._.tf��,�,� �_�_E..., �_ ��,y���.�:�,��d_�� �� �. �" �:�.�,��:� ��.�.�_�
From: "Mike Stewart"
To: "Charlie Davis"
Date: 03/25/2008 8:43 AM
Subject: 4418 Columbine Dr.
Charlie,
NWCCOG received 2 permits for residential elevators to be installed at the above address. Town of Vail permit #
06-0100. One of the elevators exceeds 50 feet of travel by 3 inches. Gene called the install company (Colo.
Custom Lifts), and told them they need to come up with a way of decreasing the rise by the 3 inches. They told
Gene that I had given approval before I left NWCCOG. I never spoke to them about this issue.
Elevator residential code hand book states that if the home elevator exceeds Rise, Speed, or Capacity that the
elevator has to meet the commercial code. The elevator company says that they're going to contact the Town of
Vail and ask for a waiver.
They also asked if they could resubmit the application for non-code compliant elevator, showing that the rise
would be only 50 feet. I told them that would be acceptable and that we would measure the rise at final inspection
and the elevator would fail if it exceeded 50 feet.
Gene, told the elevator company to contact the builder to come up with a code compliant solution.
Mike Stewart
Elevator Inspector
Northwest Colorado Council of Governments
970-468-0295 X108
970-468-1208 Fax
elevato �nwc. cog.co. us
file://C:\Documents and Settings\Administrator\Local Settings\Temp\XPgrpwise\47E8B... 03/27/2008
APR/03/2008/THU 12:57 PM N�CCOG
FAX No.9704681208
P. 001/001
Mar 3a 08 03:22p Colaradc Cusiam Lift, Inc {970} 241-7377 p.1
, ' 11141�1W�S# �O�O�d� CAIJf1C11 O�f �v�[f1[1�i'f!S
� � �L�1/ATOR�P�RA+lIT APP��CATION
' . .
� P�rmit # t�"+�� ' • 7urisdi �cX. � .
� � 30� �
i
�
1
�
l
I
�
I
�
a
E�
�
�
i
�
, .
-r�r��,
�
�rom
rax� � • �
Tot�l Fee Da�e d fieooiPt �_lQZ"ZC�G # of I�ages
Plitf Reviewed and,�pprove�l by Dat� I9�ped �'� l/ 4 . --
� . . ParritiE lixplration Daba �1'f � l0 `� .
- . ..-.,�
** A![•tlfe Falfowin� �tt�t be cbmpl�d by i:h� elev�tor cohtrac�or ** •.
Inacc�sra�bey•ellegble or mi�si�g isAfornl�ki�t vrili c�� a dols7� in th� applir�#ioe proces� .•
. .� Ple�s� c�nplete a separate �epplical3on per mnveyance.
- . .� . .. : .. _._._ � .
]urisdiclion 8u�ding Pe�mzt # � ...'~''.�� (� ^•~, ,
]obAddtrss y`iie� G�/kW�bine �u'.' P'rir►tiEr,r , ---f/G���f • ��]. %d��
Owrler Ws�rt fC��t �Pi��E►�iCs � . . .
�
Mafling � 7� � 30 � Fa /e ... � �d 16.3 ( • .
Phone # �a 3 � y 2b � � � 57� �z�r � ���
�� zg z a � 2 ,��
Dewttnr Cor►tr�sctor C'o /o ra�.l � � �'uSfp►� ,L; f f • .Z.,t � � - V /
' Ma�'ing Ad �re� �/�:C� '.� /2o r rr�cr+ �ur� fr s� • Cd �/SD�( �
Pna�e � 97� j .2�5 -- �SI ? � r-�c � ��d ,2y� - 73 �7 � - �
,� , •. • • ■v� ��v� uaaa;ana�vn7 p[W �la[ 7iiQARli 7Vr ilql'aQ01l�'F
Hew in�ailation • �.Inl� or �nbact,# �C��fi( - S�Z,�.� �1'�r' ��''
.. �no„ r�r�t,�e.,�m►,e�e�� �ar�d��er�,�acavc�
"t�escribe worlc �a: fx�f n e►.+ [',u�t�rt . • �/etra./a� �'li�,a . - -�esr�v.�1�. i �"fe.v�.
I herebY ceHify tl�ac I havQ read�and��ami�ed �is applira6ior�
a�,d kncw ti�e s�rne ed be m�e aY�a aorrec� al provislons d laws
and ardina�oes govern�g this type af work wnl be.mmpiied wfih
whetf� spedfied herdn.or net ihe gtar�tiig oC a pq,�mlt daes
' nat prrsta�tt tio g Ne ault�ocity to v!olate or tanoal the provisfatss
of �y oth� sbbe or local law.regulating oo�tnutinn w the
pe�fexman� af n. '
� � � . I o�
. . �11�1At iN!� � aTrON FE� .
Pa�ssereger ar f�iglK e(evvoor, lu�la,. eae�laoor, moviag wstk:
Up tio and U�duding �50..DQ0 af v.alu�tivn s;375.00
. Over #S�.Q� of° valuat3at =�3�R.00 pus ¢7.00 for �ch
$1,OQ0.00 or fracban ther+eof o�oer �.50,000.00 - ..
L.Ifki D�anbwaibec or p*ivabe residenoe ele+nalbe: •
Up to ar�d indudn9 #2Q.ODb M vahr�lion =$2iS.00
ovtr �n,oao oF va�on =�xso.o�o au� #4.w ror �cn
$1,OOD.Od or fra�on thereaP over �20,O�a.OD
' MA7dR �.TERATIOH 1+��
Fees for m�jor.siE�rotforo shaU be as set tbrtll In•7a6k 3-A of ihe
Utybt'rti1 Adrna�istrative Cnde or TaWe 1-A.
v�tu►rroN �; ?�77. � .
�
raTa. � 3v?• �o
�levabpr plan review at�d fieEd inspe�ciions wili be aonduebed by ftte Notth�rest Cvforado Cbccndl af Gov+�rnments. Plat�s will
be fon�varded ta NWCCaG fo� revfew and ap�iroval. SShsduie insped�ons by aantading the NWLppG E]CVat�r inspettor at
970-4�8-0295 ext 108. ' • , . .� r � _ � � / I
0
L:I
� MAR 3 1 �B
w��wre'* P*_�iG
Received Fax : Feb 19 2008 10:43AM Fax Station • Wvnton Develoonent LLC
D 2
Feb,19. 2008 11:40AM EAGLE VALLEV TEMPS No,���� p 2��
;� n
�
• �utlOns .inc
ENG�NEERINC
Letter of Record
Date:
O;t.18.08
T�;
Nlynton Development
T��wn of Vail Building Department
?�iect/Job Number.
L��t 3 Bighorn Subdivision (4418 Columbine Drive) Job # 0208-05
Po eox za�a
AVON. CO 81620
PH 870.949 7100
F�(. 970.948 3377
This "Letter of Record" is in regards to the soil nailed walls indicated on sheet S2 of the above
►rientioned project The east side units soil nailed walls were constructed by Great Divide Constn,ction,
Ir�c, and should have followed all recomfnendations provided by the Hartmann Engineering, Inc. report,
d:3ted June 14, 2006. All test resuits and soil nail placements can be obtained by Great Divide
Construction, Inc. The wall placement appears to be in the location as indicated on sheet S2 of the
fc�undation pl�n, The west side units soil nai►ed walls were constructed by, Inc. and should have
fullowed all recommendations provided by Yeh and Associates, Inc. layout plans, dated January 29,
2�107. All test resulCs and soil nail placements can be �btained by Advanced Foundation Systems, Ino,
The wall placement appears to be in the locatfon as indicated on sheet S2 of the foundation plan The
NISE backfill wdll located to the west side of the west unit was construcEed by Slaton Brothers and
sltould have followed al) recommendations provided by Yeh and Associates, Inc. layout plans dated
August 29, 2007. The MSE wall placement appeared to be in the correct location as indicated on Yeh
a�d Associates Sheet X3.0 of the MSE Backfill Wall construction documents. If there are any questions
or concems please call me at (970)-949-7100.
M�L ,Ba�kfi�� Wall
Lot 3, Bighorn Sub. 3rd �I dd.
44 � 8 Columbine Drive
��Yeh and Associates, Inc.
Consultin8 Enginoas �t Scientiate
5700 E. Bvens Aveaue Denver, CO 80222
phone: (303)781-9590 Fax: (303) 781-9583
Vail, Colorado
Index of Drawings
X 1.0 Cover
X 2.0 General Notes
X 3.0 Plan View - Modified Sheet S2
X 4.0 Elevation View
X 5.0 Typical Section
�et Revlsion
�� ��r
d�� �
$ �� �
S� ?l \?4i
����A� e�
��
w��...
°'""°'�'"` Cover Sheet
��c
��
47-01Z
a.w� ur. o.e.:
PFGA �
wuyu,e �, som �u commbm. or�w
� �' pgM Vall, Cobndo
ShsetNam6�
x uo
� Q•� FiecKpl � MATE?fAL
�. � e,da+u sox
1 t.t B�cMAlBoil phad Dslow �nd b�hind MSE
t�ch�o bloda sMl mntth� foAowMp
� p�rt • s puamp th�
No.+O it�w �haN h�r� � 9quid Iknit not
nces�ding 35 p�R�ed md a pinddy
ind�x not sxc��dlnp� 6p�rc��d vvh�n w�bd
in sccordma w�th AS'TM D43iB.
12 MSEFacing 9oek�
12.1 M3E facNp 61odo shdl M MESA bloeb
or punN�M. m�wf�edndfor MSEwetl
eon�Uueuon �ed ap�bb d d�vsbpinp �
mmimum int�r6toek sluu �tn ri of 9C0
16� �r R wIM w wthout pwt�
nfifo�esm�nt� in�talhd 6�twNn bbcla.
12.2 3h�ar dip� orpm�. Providad byth�
rranufadurr. �h�p b� MxaM�d b�twun
th� fsdnq krloeks.lo afd 'm block �ipnrn�nt
�nd inenasinp int�rf�a aMv b�twwn
blodu.
12.3 Vads �nd within-th� M8E t�dny bixlu
tha! b� f��d wuh � dsan p�pn�
confortninp to th� Wnck mmuf�cturae
pnddion nquuam�rt-
i.3 Conrnb
13.i Catin-RMcs concnM sopinp sMN Iw
form�d on ttu tog row d MEE taanp
blodce. n ne�d�d.
1.3.4 Ths cona�l� �h�ll nach � mintnum 1&
d�y compr�uk�� ��n{�th of f,000p�i
tut�d m�ceordane� wdh A9TM C39 md
wndin a ma�nmum coner� �ppnpsb
sia� of 318 inch.
13.3 ConenU th�ll conhin aK mtralnm�nt
•uB�bl� ior �vw s�own �n �ewrdsnc�
wih AC12Gt.
1.3.4 hi��amum h�iyht ot mpiny sluA b� 10
inches.
1.3.5 Mmmutrt d�th af eopinp ehall h� 16
inelus.
1.3.6 ToF of copinp shd16� fln'wh�d to � smooth
�udac� �uiubb for naivirtp N»
pertn�nsnt d�ckfortn {by ofhenj wiCiout
produanp atrwa eam.w�sUon�wAh�n tha
cophy.
��Yeh and Asaociates, Inc.
coneutting Engi�►oere 8c sciemdefa
5700 & Evms Ave,nae Danver, CO 80222
p�ne; (303) 781-9590 Fax: (303) 781-9583
1.4 Wiidotammt
1A.1 Prim�ry and 8econdiryR�nfwo�nMa
�h�d b� SynthMk Irtdu�trl��4�A
y�ot�xtl�. or �quNabnl. wfth � MARV
VYId� WMth T�n�ib 8hm�lh in hoth wup
� waR dincEons d 4800 i6dR in
accordma wth ASTM D 4696 �nd �
minimum flow ntt of 10 Q�VmInIR"2 M
�cccrd�na wth ABTM D 4481.
1.4.2 Oahrsniz�d shu mchora �nd concrN�
�ncho� sM9 �thch th� prim�ry q�oqodfl�
rmiforam�M So 1hs �Aoicr� ha whua
spacdi�d to dw �bF � puAout �tnnplh (Une
lo�dj d 1800 A�/ft minimum.
20 i�oees_r.�LLU4�4! CONBTRUCTION
2.i Du� ths pramee of ndrtin9 oonstiue6o4 aich ae
bu0dfnp wdl�, soli n�l wdh and I�ry� eobbNs!
bouldv� aq��aM to fR�. th� rmkmurtp►oc��d
nutlousfyto wad dam�Qinp �xhtinQ eonRruetion
acli n �09 naif�md/orprwiou�yirotal�d
ntiforc�d ihda�u he1nQ.
2.2 mdwMh ��ae�im�nchn¢h�� p�einpationa
dovm on th� drrivin�t.
2.8 Tha s�utUny found�tion b�cldAl �hai b� bv�Nd to
sRprwdmately Elsvetlon BSBY�' (a ma�dmum d
] fNt �w� tM mp of spn�d tootinpj �nd
d�an�d ef fA d�iK�riow m�e��h (ag�nk�_
bouldr�, Nc ).
2.4 Th� M8E MdcflU w�il ��I h� �mbsdd�d 9-inchn
(t-hlxk; tido tho Iw�Ud found�lbn baddiH.
2.5 The found+UOn fdl b�nsah 16a NI� h�nidll rall
rhdl b� compscnd tc 95% d 9hndud ProeWr
muumum dry dm �ity wdhirt 2K of optlmum
moiku� m�aro�dxcn wkh ASfM D898.
2.6 Th� MSE b�ddiA ehtll b� pl�ad M Idts na thid�sr
th�n 47nch�a tar hand-op�r�d eompacNon
puiPmuR. Th� btckllll sh�N b� pl�ud in
honzonlal u�rt and eanp�ct�d �pNnt horimwi
aA�ca. B�elddi �hNi b� �ad ud campactad
rquanUally from 1h� fsanp bbdw to th� b�k af
iho nfiio�emrMs to sd in t�nrion
2.T Th� �dcfiA �hall b� eomWG�d b�i �t 96% oF
muimum dry dmalry n d�tumin�d by t!n ABTM
D698 (8tandud Prodor`, �t optlmum moidun t
2%.
2.8 Prc� ninfo�eam�rrts ss shawn oe 1h� dwwinga -
mefudNp wrepPmy Uw 6acIQIN adpant b th�
ehotc�t� wall. ,4� rNnfo�rrwnb �+� 100%
covus�� md Nt�A �nd irom b�dr��n th� M9E
f�caiy blockr io 4��.�hotra� wal.
s
�
�� r `:�Pu
����WAL rc�'
Z.8 y�lh�� �p�clH�d 1h� rNnforc�m�M�hdl hs
anchond to th� �hotc�b f�c� u�ny arpl� ��I
�ndconenb anchon.
2.10 Tf» M8E 1aeMp bloels sh�ll b� pimm�d. af
nud�d. b flt mu�y �p�inK �hokrk� vrdl �nd
buildinp wall �t dt7nr md. u indkahd. Addkbnal
y�at��is shsll b� imt�bd at th� cor�ct b�tiw�e
tM M8E ficinp bbeks md ahokrN� to prevant
aod �mdon b�twwn th� black �nd �hatcnh.
3.0 De81tiN PARAMETERB•
3.7 Sal 8de�gth Paran Ksrs Teble 1
T�Y 1 So� PtemLw Uaed in Inlsme19ta6�llr
Anslrs«
�Firctlon Cdws(on N�pl+t
Soll
3.2 RNr�Pomom�rd R�ductlon F�dor � 0.20
3.3 ANn. I�m�l 8tab�ptY multlPM rndp� FOS � 136
4.0 MIl�'R�1�EOL8
4.1 Fi�id vmmRledon otths M8E b�ddlll w�Ns
dFn�ndom, auch u ofab irom buiding waA.
hdphls of M8E baelddlwatl and roinFarcemant
bnyffia N nqui►�d byth� coMndor.
4.2 Y�h md Aax��. Inc. v� notrNpondbbtor
eondueYny construatlon qu�ty eo�fioll��b or �IU
oMwntlon�.
4 3���A�aoc(�tmtn aron �hyd�y m c�mnpNw s
work '
4.4 &+vy Contol provW�d by oth�is•
4.5 Stam runofF NNtl b� direcbd �w�yfrom th� MBE
backAN rr� and wsi�r ahaB not b� �No+red to fload
or pond wthin tM Iim� d tM work dudnp
conttrucNon.
4.8 wal�adMp �� �w Korm runaFto pond
M�
5 Q F..,.. �c.rr ueTCO�e� niieurmcs0
iQLt YrWt��t'R�ta1�i'K�peWQ�atleMa'r
Iat�tls �b')
IR �
'�E oe c" ae
�c
orammt
Pnpww Far:
PufChY�
o.�,.���
uc
��
27-072
Dnwn by: P� p�
Aupwt 2p. 2007
CIMd��E by: �
General Notes
p�pJ�ot I ShaelN�ba:
1418 ColumbqN Drlw x �
Vlll, CobndO
��Yeh and Asaociatea, Inc.
(;ppgl11Li1� Etl$IIIGC[B Bt $Cl�t1818
5700 E. Eveae Avame Deavor, CO 80222
phono: (303) 781-9590 Fax: (303) 781A583
���w
a
E.s�.0 � w� e.as wa H.u�c A�na
eyol BYl�orwWbnFxbmmma
IM/Oaia�Yll�
MGAI WY I+WR 4 allresthm d�9r0
qn 9�IIIp dIMMb 90 G0 Mic•
�.r s�n bm vo da om�rrour o. ar
Mu.yrmms-uru.omaarura
J6Y kumNron Pln Ypu w AwtlM M J.
r0o d 8D41na tr IMmrbn m1'. 1M
�W aYbIMwO MWKMAIEbrt.N�wrw
Y0 b/ Rdn� a1MM�1on Qafp�Y. LLC
wl MMItl NAAtl P�bwf wrWru�
AL
IDATION PLAN �:,,�_,b �
�
E�
��
$� y �, ��
�ss��WAI ��`
Prep�nd For:
Purchw
��,
LLC
Rq�at NumbM:
rr.o�s
oi.wn by: �
Gnck�a by: �M
Plan View - Modified Sheet S2
D�tK
Aupw! 2Y. 2007 �� 4116 Columbim OrM �� �
Vat1, Cobndo
.... .
� aro�w rwi m
AeIM«cw 8hotaeoe shorY+c
Trlm Blmlc eo Flt WMh Ap�lnst
�
�
�
�
�
W
��Yeh and Associates. Inc.
Coneniting EnBinaeas & Scientiete
5700 E. Bvmie Avenue Danvet, CO 80222
phone: (303) 781-9590 Fax: (303) 781-9583
�
q{q�h /yqN gbN ro BMtcrta in hmt d F�dnp &ooia
wNh Caronb Anohcn ewry 2-twt (Cih snd onl�.
AB PdrtwY RdMaoertierK Iryere In 1M� 3heded Replon
i1� �-to he erchorsd b ShoOpete 3halnp
� - r ��
%` If �
r�j� i
��f -
�� ,
Locdlon d Prtrrory RNnlarcemant
'(9aaarWary Relnfaroertxnb nd aFown - 8es Typkd 3acllon)
npprcodmm Top a cmcrKe CoWro
�
� =
■
�
���,�
ird�lon Beddlll
8687-9')
eet Revision ""P'"d �
n.Nwm.�. ci.amnr RE Purohw
�^�� � °'""°�""� Elevation View
��c
Pmjsot Numb�r.
�� 7�/�'iz � rt-o�s
� ��
��a�aVAl �� om�n er• PRM Aupwt 2Y� �007 P� 447! Columbin� Driw
a,.a�.a nr: � v.n, cowraeo
Bheet Nombr.
z �o
��
E�dedor Face, Building W+
MSE Block
Secondery Rei��
Wall Layout Line (Final Qrade at Wall F+
Final Grade—�
��Yeh and Associates, Inc.
Consultin8 PnSinaere & 3cientista
5700 E. Bveus Avmuo Denva, CO 80222
py�� (303) 781-9590 Fax: (303) 781-9583
Concrete Cep end Shaded Coping Area (by othere)
� Fnal Grade
Reinforcement
—Sheded Area Indicetes Shotcrete Removel Below Final Grade
�
i
�
��Varies from 2-ft to 3-ft �
Extend RL to shotcrete face and �
wrap.
� y �O
� 28793 �
yi.�, � a�
sB��WAI ��`
��
�a�ro
enota.n u�u
Npk 8W 8
Cana�b Arc�a�
��
Pnpnd For:
Purchw
°""'��""` Typical Section
hoNat Nie�b�r:
27-012
D��wn b1r• PRM �r P�
/u�pwt IP, 2007 Mi! Columblm Drlw
��*� �• p� Vdi, Cobrado
Bheat Nnmbr.
x so
�`e,�,rr�ar�ent Soi1.N�!if �a���
Lot 3, Bighorn Sub. 3rd Add.
4� �8 Columbine Drive
Vail, Colorado
Index of Drawings
SP 1.0
SP 2.0
S P 3.0
SP 4.0
S P 5.0
SP 6.0
SP 7.0
SP 8.0
SP 9.0
SP10.0
��Yeh and Aasociates, Inc. �`�07 �
Conaulting Bngineere & Scientiets
5700 E. Evene Avenuo Deav�, CO 80222
Phone: (303) 781-9590 Fax: (303) 781-9583
Cover
Generai Notes
Plan View - Structure Sheet S2
Plan View - Soil Nail Walls
Elevation View Wall YA & YB
Elevation View Wall YC, YD, & YE
Elevation View Walt YF, YG, & YH
Soil Nail Details
Drainage Details
Tension Test Details
��
Purchw
Ww1oPm�M,
� LLC
���
Numb�r.
�, � (ss°�
�� z�at2
����IVAL ��\ D� � PRM
� � YRM
Cover Sheet
WM:
F�bru�ry 1, 2007 P� 4�16 Columbin� Dr1w ���
V�II, Cobntlo ��
1 A SOIL HWL WALL MATEPoAL�
1.1 So1 N�s
1.1.1 Bol NdY NWI ca�l d padW. �PaxY
t�NW. ANbrm�A No.10. C�nd� 7� Nr,
weh N W�m� AFNn�O br m
�.�s ea��a.n�.ar r,.i a �.o�rwna.
1.t.a 801 NN Qat th�N emqM d rwt oanwd
a �a�Mn�nl �nA h�w � mMmun 26
dry compnalw Mnplh d 7,M� pd
1.Z SMp D►dm
1.2.7 O�oeaepalM Btr4 Dnln� 76�kidia wld�
Nrl b� plwd an 1Z (eol e��.
�.a w.a.a wr. r.ene
7.3.1 WNd�tl WM Ftlrle nYforc�tn�rt tl� M
on� (1) Yyw af 4x4 W2.�tWZ.Y.
1.4 8hde�b
1,�.1 9hWerM� tla9lrw � mWmun Z6d�y
earn pwrM tlnnOlh d� P�G
1.6 MYNbramrt Sv
1 A.1 W W► b�rf �d wAkal tMlNwn �h�q b�
�fam�l No. 4 OrrN !0. or �kwnl
2A
1.7 Th� matl Mt NaM not b� �te�v�Md urip 11w
diak�b �bov� h d Mpt 16 houn old.
s.e on aw eauan un, ur � awns. r r.4r.a..�w
abnd uid�rVn boCan dtM shotrnb md
twmlwb h p�rlmMU drNn.
3A
a.� sa ann�tn P.r.m.an eona Mrmpth k
a.�.� na �rrm.t. aeu�ax+a
aun.�w r ao �.i.
7.12 TFa aeY pw�mMu� und In d� an
eaMdlud Y� 1'�bM 1:
T�bM 7!oM hranrEr� W M Y� MeP� �
Mdyw
I rirlNl �
Pikqon CoMMan WNpli
801
q� Tp 160 1
a2 R�das dlMMy
as.t tr�nrime�y
a.t.�.t aou�o►ww sona �a.rqn� - �.o
s.1 Du� IM pnwne� or wtMYp soN nMl wrb �etl 32.1.7 Oroued Nd YMW � 1.82
pry� eabbNslbouW�n �ardtotlds p�oind as3 @�d�l S1�OIRy
rqM wd. m• �ece.v.la eun pnxyw aWo�y co as2.t sldhp � �.e
pold own�onv�inp aidlor d�m�yYq w� � 322Z Owturtino ■ 2A
rbbr pnNOUMy InM�Ntl nYRarad dqknE� 3S3.i MrYp C�p�e=Y' 2b
3.2A OIObM 9ubllty ■ 1.86 (nsuma caMNwour
2Z �� thi W kul�d M bntbnt rid 1:1 lNek4op� a�bow eol fal wdh
NnpYr �e thow� on tFr �xMw• 8.3 Lo�np .
2.3 WNdrd v� inMh �lal b� pYad �t Nat 3 Ntetr� 3.3.1 11QhN F.aAh PrMqh `40 Oef
11oe1 tlu e� ha ud tMw �I NMt 3 YIChN of 3.SS MydroeLtle W�dtq ■ naN Y�dkMd x '
Nptarl� eowr. W�ns dmah � b�'1w¢ praMNd
iYlp�d" or 1N wt�P fOp�tl1M �o1�K VI�
draunhrMiN d�IMI ki�b iMNmum) wIh d 4.0 u� � usn �a
MMt 4 aou�wYw +2�Nichw (d NElia /4x4 x� - ------
a.� flra wAle.non orur pouna eonNmna ey
2.4 H� �kp Oro1wd oonAlaM ooaM 1M �1 �xp�rNnnd p�obelMfle�l MqIISM b
�e�wllon tlwuM b� Mm buldlMd nquk�d.
}bnpY�p � MIMn bNln �tst� nuNIY 42 Ae�uOIIMd� io MN dnlpn nly b� nq�hd
WquOporlW �v�lkn fYq. 11w �owW rrls P�ndlnY Mid vulkrlon �dbr P�Mout bStirq
myMrn b� YWMA �abp�1� Mi� wdMn d mehas.
b�ml b MN �PO►aocillM dal� bptbn prla l0 4.3 Sunny Cairol praNA�d by dMrt.
nmw�l af � a�parttp bwm (w �oM 2.7). 4,t Svll P�nmMaaA3►amd eadlo�s provW�d
4.6 IYIY�Nnum hp � for No. 4 w�Nr bv� r by o1hN�.
�A. f��� �t�. P� 4.6 w�N �r oontr�elofl• wiA b� eamplN�d an tHe
1M �tmo� b�tvw�n � rrN.
7.6 Sa� ra1 n�e �nA pl�Eu my b� Ma1�Md pAm to
MiWoM� phaiaat; how�v�r. �hetvd� kH1
oompYay fw ni. rn 6Mina u» phlR
��Yeh and Aasociates, Inc.
ConSUltinB EnBmees9 dt Scientieta
g�pp g, gvans Aveaua Danver, CO 80222
p}i�e: (303) 781-9590 Fax: (303) 781-9583
Prap�rw Far.
� Purchw
�.�,
LLC
vm�t Number.
_ / � /yp.'7 � 27-012
Fas { � �,`� a.w„ nr: �
�4NAl �
c�uac.a ny. �
General Notes
O�fx
F�brwry 1, Z007 �t 4416 Columblm Drlw
v�i1, Colorado
ahax N�6e:
�
j���
„ ,.
�r�—=' �'.
��
�� ��
I�?
�'"7�^'' �.',�.-,;•-�. �
�.I „n ,'.
�iii� �r��
� ,�
�i ..:. "`�,l�
� `�
�' �
.+ ��:�p.i.
�� � •J'.'I .
� ��
�
��Yeh and Asaociates, Inc.
Consulting Engineee dt 3cimtists
5700 E. Svana Avmue D�va, CO 80222
phono: (303) 781A590 Fax: (303) 781-9583
..,� I I hMf M W..
�
�
ry
� ��a1�R� aiuw•ro � e� ��
} �il �srr�iw�� �i
` �,� y ' � �i _...
�
. _,.
—�-- '� �s :
� i� _—�___ �_ _a ^ ' r � - •
� � � L LJ �
_ �
.. „ I f �i�' .r . a
___ e� L �
o �
`�, - - �'1 ���� p � �
� «�.... �; °r - - -� =i1- c°o=n
�C n � • � � , •� t A , ` •
��� .� .� ..� . . ,
I .� ,+�� . . •
�il� �..:i,_,,,;,�., �: ■ ��:� • j •
�. � ����i�� ;.��'��i�
�y �� � � '�' ,
� , �� �`�
�,� i�� — �� :��"' ': •
_i �=�� ��.v.��. _-
� ° ��� ��
� _ �� �� �
:�„ �
, r
rou�a►na�
nrn
�— L
�Ib FO�:
PYI6hW
' °""'°�"'"` Plan View - Structure Sheet S;
' s uc
28793 P1°h° Ninbio
� ',� �� 27-07Y
� br• o.ec
sB��IVAI ��' PRM F�brwry 1� 2007 �� 4416 Columbin� DrM shr x�e.:
� br• p� va16 cola.ao sPa
��Yeh and Asaociates, Inc.
Coneultiag Enginoae & Scientieta
5700 & Bvaoe Aveaue Denva, CO 80222
phono; (303) 781-9590 Fax: (303) 781A583
�
M1��A' ���
� �'�'�-�
��..���•.�� ��.�.. . �
� /
i
\ - i
�
��o_
Wall YD
ar.p.�.a wr:
E Purehw
D�vdopm�n4
� s LLC
ProJ�at Numbx:
�,C�, �yl�. ��' 27-01�
?
Fss �'� o�.wn br• FRM
��WA1. �
�0°k°d � PRAi
Wall YE
�'
�
Plan View - Soil Nail Walls
Dab:
F�brwry 1, ]007 �� 4418 Columblro Driw g�N��
vtl�, co�or.do aFs
�
I yIr -
8E08'-0'
Top d Shc NY Wd
Soil Neil Wall
by others
ee�e�-0'
�eonom or aoa raa w.n
BuWhq YV�M
nw
� FTO 9bp'-8'
�
�
BE04'd'.
7'
. . � '-, ,
� ❑ ❑ �
�
� � ❑ �
Wall YA
SO ft lonp Soil Nells
on a 3'x5' (V:H) patbm
�
20 tt lonp 8011 Nalls
on a 5'x6' (V:H) patt�m
��Yeh and Aseociates, Inc.
(,'ppg111�1D$ Fd1�O0[8 8L S'C10R}.18�8
5700 E. Evaae Avenue Deava, CO 80222
pgione; (303) 781-9590 Fsx: (303) 781-9583
BEI
(Top d SW N�I
� Locatlon of 30 R aoll nall
+ Locatbn of 26 R toll nall
❑ Locstlon M 20 ft wll rril
� Locetbn of 15 ft eoll nell
auWtq w�H
Nots:
1) Top of 3011 Nail Weil to be fleld verNkd by contre�or
to assure elevetlon Is 2 feet bslow frol pmde.
2) Flrst Row of 3011 Nalls are 1' below Top d 3oli Nell Well to provkfe
connectlon tor ho�lzoMal eleb (eee StrucW�e Delell 3l311)
Wall YB
15 R lonp Soil NMis
on a 5'x6' (V:H) palbm
, P�.orw wr
� Purchw
�
°'" �"'"` Elev. View Wall YA & YB
� �:
�j� � /' 7 jAp � � i7-07i
�1� �?
���aNAL �� �� �� p�pryvy �, ppp� P� 4418 Columbin� Drlv�
cnwcw br• PRM Vdl, Cobndo
s�x��:
sPe
!61
Wall YC
20 ft lonp Soil Naib
on s S'x6' (V:H) patbm
��Yeh and Associates, Inc.
Congulting RIIgiII0e�8 & SCildltiete
5700 E. Evans Avui�uc D�va, CO 80222
phono: (303) 781-9590 Fax: (303) 781-9583
eeor
� Locatbn of 30 R soll
-I- Locatlon ot ?b tt wll
❑ Locetlon of 20 R soil
� Locatlon of 76 ft aoll
8675-0'
(Botlom d 800 NN Wr
e�arw ww
eeos.
�'
NOts:
t> ToP a son Ne�i wan �o ba nab �rerined by �omr
to aswre elevefbn Is 2 feet below fiel y�ade.
2) Flrst Rvw d Soil Nella are 1' below Top of 3011 Nall Wall to provide
conneetlon for horizordel slab (see StrucWre Detali 3/311)
Wall YD
25 R long Soll Nalis
on a 5'xd' (V:H) puttam
3et rcews�on
RM�IdW..n c�rok.a M
da�a�a� a� r
287�i
�+Q, .r x r�
F��a1VAl ��`
Wall YE
2S it lonp Soil Nalla
on a 5'u8' (V:H) patEam
r•n-.0
�
P�ewrW Fa:
Purohw
°""� �""� Elev. View Wall YC, YD & YE
DraNpnNn
L
Rolbt M+�br
r�-o�z
Onwnbf� PRM � PmNct SheetN�bar.
F�bruvy 1, 4007 4418 Columbin� Drlv�
� � pgM Vdl, Colorado �
� Locaaon or 3o n,on ne��
+ Locatbn d 28 fl aoN nell
❑ Locetlon of 20 it soll rroll
� Locetlon of 16 R soll nell
8678'-0'
(Bolbm d SoN Nrl WN �
Well YF
20 R lony 8oli Nails
on a S'x6' (V:H) patbm
��Yeh and Associates, Inc.
Conealting Pagince�s 6t Scientisle
9�pp E, Evene Avenue Denver, CO 80222
phona (303)781-9590 Fax: (303)781-9583
— ease�.
eser-0•.
❑ Q
❑ 1
❑ �
aeor-e•.
��
Nobe:
1) Top of 8011 Nell Wall to be fleld vertfled by coMractor
W essuro elevetlon Is 2 teet below fiel prade.
2) Flrst Row ol80ll Nells ero 7' below Top ot Soll Nall Wall to provids
connectlon tor horizordel sleb (aee 3tructure DefeA 3/311)
Wall YO
20 R lonp 8011 Ndls
on a 5'x8' (V:H) palbrn
�s
�Q �%�
P� �%i/yp ?�
f5(
���oNnt �`'�`
aeee'e'-0'
Wall YH
15 R lonp Soil Nails
on a 5'x6' (V:H) pstbm
Pipnd For.
PYrcllw
°'"'°°'"°"` Elev. View Wall YF, YG & YH
LLC
ProJ�a Nw�Wr:
47-012
or.wn nr: p�
� F�bruvy 1. 2007 P� 1418 Columbin� Drlw �N�
�h°d`°d by' PRM VNI, Colondo �
� !'�!'d/2' MAd 9bN Platw
p�dyW Hel� (B� Ola + 1/47.
EmWd Fsd Hadra�
Y� 9hetwb
Ha� Nut
r/ wlnr
otarrN Fodnp
on. (7) a�oonsx�uw. /a a.ram.a wMka .nn.nw eQ wnlna pine..
Tro (2) oontY�uow H d�fam�d rdr ban Mhlnd plola
�-lhoipN� or Nal Oraut
Epmcy-Caarbd� No. 10. Oradr 7S NI-ThnaA 8� wNh Wnfrd�n
�1 `-NaA Orout
T�o (7) loy�n o1 M4 M2YxY2Y
WMGA YM F�7e MYifaolnY Naad
ot € M 9hotantw
3' Min. 3' Nln.
FlnLhsd Wall S�ctlon
rsr
wn
Conn�ctor Plate
r�r
��Yeh and Associatea Inc.
Conaulting Engineae 8c 5cimtisfe
5700 B. Evms Av�ue Denva. CO 80222
pbone: (3p3) 781-9590 Fa�c: (303) 781-9583
,�,
Typbd PmM
—���— 1
't-1-1- R.�nrwanv
� �.n u/.n� - s ae..w« vu�. s-na�« (e tia�«)
Typieal Shotcrete
Panel Steel
r.r
r
28793
�� ��,y ?�
�
s��oN�� ��'
Edp� af Pm�l, a� nwdd
lo� 1.�9th (min)
.._ . �.. �..i��d Mhk�Vrlbal 9fIK�n�r
p�pr'�d Far.
PYR.II�N
°'"�"'"� Soil Nail Details
���:
r,-0,s
ornm by. � pp� p�
FNrrwry 1,1007 4116 Columbtn� Drlw
a�.ana br: p� v.u, cobndo
SheetNumLr.
sve
Geocompoaite Drain Stripa
Centered between offeet nail columna
Top of Wall
+ + + + � +
N N N
N+ N+ N+ N+ N
� ( ( ( � Ground Nails
Bottom of Wall
6—R
�
Geocomposite
5 Drainage Strip Detail
Not Ts fod�
��Yeh and Asaociatea, Inc.
�'AOS11111II$ Ei1g1IIOQ9 8L $C1EIIU8�8
5700 E. Svans Avc°u° Denver, CO 80222
phone; (303) �81-9590 Fax: (303) 781A583
Battom
of Excavation
T�ICO� ih/a��
e Toe Drain
Not To loeM
Shotcrete Facing
poaite Drain Strip
3eotextile Againet Ground)
i atrip underneath ehotcrete.
�II
Prp�nd For:
Purchw
�t � DwNopm�M, Drainage Details
uc
yh ��� Fmpal Nunbsr.
� � rr-ou
.?
�ss�aWAl �� D� � P� F brwry 7, 2007 �� 4N! Columbin� Driw
� �' pgM vall. Cobndo
Sheet Num6m:
svo
1. D��Iqn Tpt Load (DTL) tor proot and wrlftoakion t� � 23 klp�
2. A}br �ucca�ful proof tnt compUtion, cut tat nail off o� far trom 4h� face a�
practicol ond flll at mueh oi tM dAll hok a� procGcle with �hotcrsb. Flnl�h �hotcrots
to provids a 2' crnx minimum owr tM �nd of th� G�t natl.
r�i)N� ►L��L T6T �E��P NOT TO SCALE
��Yeh and Aasociates, Inc.
ConeultinB Engineas dt Sci�tiets
5700 E. Svms Avenue D�va, CO 80222
phona (303) 781-9590 Fax: (303) 781-9583
P[aGi
Tsat Sch�dul�
Load Hold Tim�
Incr�m�nt (min)
��)
AL� Unttl stcble
0.26DT1 Untfl �tabl�
O.S007L Unttl dabl�
0.75DTL UnNI stobl�
1.00DTL U�UI �tabl�
1.23D1L Unttl �tabl�
1.80DTL 10"
• AL�IVipmm�nt Load (�0.05DTLJ
« R�odlnqt at 1, 2, 3, 4, 3, 8 and 10 min.
Hold a� addkbral 50 min. it mowment
bstween 1 and 10 min. sxceW� 1 mm (0.04 in.).
R�adinq� wsry 10 min.
: � .�' .
iry �hotcr�b . .
ao�k_o�t� ' „! /
\ .:. ..
�et rcev�sion
iuvwom�rr c�wa�a M
dlorCorw6uaMon Prm
28793
� � �1 ?�
�
as��NAI E�
4'
'.���.�s)
/-/8 Gmd� 75 bar� bar
/ ntrall:�n
...�,, �
F� r 0�
�t/��/ �
l `�1p' d°nd
SACRIFlCIAL. TESi NAIL
��
Pro-Productlen V�rlflcal�on
Tr4 Seh�dula
Lood Hold Tim�
Inc�m�nt (min)
��)
AL� 1
0.2SOTL 10
0.50DTL 10
0.7SDTL 10
1.00DTL 10
1.25DTL 10
1.SODiL 80
1.75DTL 10
2.00DTL 70
hol� wall
�S'
�1
P�nd For.
Purclw�
°'"''°a"""4 Tension Test Setup
uc
P�opa� Nu�nMr
27-012
ornwn DY PRM �0� �
F�bru�ry 1, 2007 �41! Columbin� Drlw
� �' p�y Vall. Colondo
anes r�ber.
iP10
.
•n
� �
• lutions .inc
�
E N G I N E E R I N G
Letter of Record
Date:
07.25.06
To:
Town of Vail Building Department
Chris Gunion (Building Plans Examiner)
ProiecbJob Number.
Lot 3 Bighom Subdivision (4418 Columbine Drive) Job # 0208-05
PO BOX 2494
AVON, CO 81620
PH. 970.949.7100
FAX. 970.949.3377
This "Letter of Record" is in regards to the following concems that the Town of Vail plans examiner
(Chris Gunion) had on the above referenced project. All soil nailed walls indicated on the foundation
plan (sheet S2) will be soil nailed by Great Divide Construction, Inc. and should follow all
recommendations provided by the Hartmann Engineering, Inc. report, dated June 14, 2006, that has
been provide to you. We have reviewed this report with comments conceming certain walls that were
not indicated on the report that should be soil nailed. I have been in contact with Burt Hartrnann of
Hartrnann Engineering, Inc. and have an understanding that the report is a preliminary analysis. As
excavation begins, site visits will have to be made periodically to evaluate the existing conditions. Our
office will be in close contact with Great Divide Construction and Hartmann Engineering during the soil
nailing process to ensure that the structure can be constructed according to the revised structural plans
dated 07-25-06. It has been indicated on plan that the "top of the soil nailed wall not go beyond isolated
footing". Also the maximum backfilUvoid requirements and bridging befinreen soil nailed walls and
foundation walls have been addressed on specified details as indicated on sheet S2. If there are any
questions or concems please call me at (970)-949-7100.
�
Hartmann Engineering Inc
1266 Texas Avenue
Grand Junction, CO 81501
Email burtham(a�,bresnan.net
June 14, 2006
Mr. Thomas Weber
Great Divide Construction Company
P O Box 1292
Gypsum, CO 81637-9708
We enclose our analysis for the soil nailed excavation support for the Purchase Residence, Lot 3,
Big Horn Subdivision 4418 Columbine Drive, Vail, Colorado 81657.
The permanent concrete structural wall will be furnished and installed by others. We enclose a
procedure sheet for control and design of the soil nailed wall during construction because of the
lack of mass soil-rock properties design information. We have prepared an analysis of the
geometry required for the Soil Nail excavation support wall for each wall section you labeled as,
A, B, C, D, E, F, and G, H, I., J, K. These walls were selected from Foundation Plan, S2 of
Structural Design Solutions Engineering , P O BOX 2494, AVON. CO 81620, 970-949 3377.
Each depth of cut 19' 30' and 40' has a separate analysis set. Each data set has 2 copies of the
graphic of the calculated nail geometry and 2 copies of the 6 page analysis data sheets for each
depth of cut wall height.
The soil nail pattern used in the stability analysis was 5' high and 6' wide. Adjustments of the
nail pattern in each corner are planned depending on the nail layout in the corners between
adjacent panels.
This analysis will be adjusted and completed as the work progresses.
Very truly yours,
HARTMANN ENGINEERING INC.
�
Burt E Hartmann,
Registered Colorado
aE�,sT Town of Va�l
aF:r_ M;q;�,9t�`� ����� ����
-._-�_,y.� �
� �3-� 4
N ��
�3aG' a�
� � � � � ��
D
JUN 1 � 2006
TOWN OF VAIL
Transmittal Information
Purchase Residence-- East Vail, Colorado
Excavation support at Elevator Shaft
Vail, Colorado June 14. 2006
Burt E Hartmann, Colorado Registered Professional Engineer 5374
The wall must be designed during its construction. Excavation progress will reveal new
information. Ground strength data is not available prior to start of construction. Techniques for
in-situ soil strength are not available in the typical private laboratory in the region. Testing soils
in the field is not simple.
Pull testing of completed soil nails on each level will provide guidance for the next level.
A preliminary analysis has been made with the CalTrans SNAILZwin program by using assumed
values for soils based on our experience in the area. No testing method for in-place soil and rock
debris currently exists for the soil and rock mixed talus prevalent on this site. The most
important soil parameters are :
1. The ability of the nail to resist pulling out when supporting the given soil mass,
2. The geometry of the soil block reinforced by the soil nails
�. Support will be reviewed as each level of excavation and support is completed and new
information becomes available. This review will be made by Thomas Weber and I, as needed
and from time to time, by significant changes in the soil mass characteristics.
Seam and crack mechanics control the soil-rock mass behavior. Rock masses have been deterxnined to behave as an
assemblage of rock blocks and should be considered as crack mechanics. The material properties of the intact rock
material have very little effect on the mass behavior. The same is true of soil masses which have been disturbed;
cracks or seams control the behavior. We will use the following excerpts from my book, Soil Nailing Construcrion
version 2.8 Table 4-1 on this project.
Field pullout tests on nails as required by the design engineer of record
Slope natural angle of repose on surrounding soil slopes is indicative of the internal angle of fricrion in the soil-rock
mass forming the slopes in the project area.
Soil to grout bond tests in field will used as a part of pull-out tests
We will use the CAL-Trans SNAILZWIN program version 3.1.1. or newer versions as they become available.
�
.
.
Hartmann Engineering Inc supplement to first submittai
drawing for Purchase pro�ect shoring submittal
Hartmann Engineering Inc
1266 Texas Ave
Grand Junction, CO 81501
970-245-6200
July 25, 2008
PIAN of SN Walt to be shored 1 Of 2
I 15 —O �
19X40
D
C � �
� � �
- � X
N
� �
N
iJ
, /
�0
n��
/ ��
� �
2
\� . �
\ 9
-f-
�
� �
�.
f�. �
o,
� E
�
�
1 6' —0'
�
0
�
�
�
Note: Add 1 nail at each level �cm° r�e ��
and length as adjacent nail on wol'. F
PEGISTFR�
O q O
Q'�;�.P�'�` M H'y`'�
°e:� ,� p� �
;� 6JA' : z �---
Town of Vail
o��� :� �
o�Y
'�p� • O l 4 �
C�C����1���
� s zoos �
JUL 2
TOWN C�r� —
!`�
2�_���
-I `\��� 6 ��',
0 1 0'
N L
1 4'
Note: WaII K has small. and 'ccc v.�;:'':
extensions. Nails of equai lencih c� c
spacing shall be in�talled along .ne
same horizontal level to fill ou� t�e
pattern as determined in the field.
Nail spacing to be no more than 6
feet horizontal and 5 feet ver',ic�,
apart. Nail hs will be c'; 'er, �:
the lengt �apo��,_ t nails.
5374
File: PURC-3
***************************************************
* CALIFORNIA DEPARTMENT OF TRANSPORTATION *
�� * ENGINEERING SERVICE CENTER *
' * DIVISION OF MATERIALS AND FOUNDATIONS *
* Office of Roadway Geotechnical Engineering *
* Date: 06-14-2006 Time: 10:10:49 *
***************************************************
Project Identification - PURCHASE_C_19'_Soil Nailed Wall
--------- WALL GEOMETRY ---------
Vertical Wall Height = 19.0 ft
Wall Batter = 5.0 degree
. Angle Length
(Deg) (Feet)
First Slope from Wallcrest. = 20.0 24.0
Second Slope from ist slope. = 10.0 12.0
Third Slope from 2nd slope. = 20.0 20.0
Fourth Slope from 3rd slope. = 0.0 0.0
Fifth Slope from 3rd slope. = 0.0 0.0
Sixth Slope from 3rd slope. = 0.0 0.0
Seventh Slope Angle. = 0.0
--------- SLOPE BELOW THE WALL ---------
There is NO SLOPE BELOW THE TOE of the wall
- --------- SURCHARGE ---------
There is NO SURCHARGE imposed on the system.
--------- OPTION #1 ---------
Factored Punching shear, Bond & Yield Stress are used.
Page - 1
--------- SOIL PARAMETERS ---------
Unit Friction Cohesion Bond* Coordinates of Boundary
Soil Weight Angle Intercept Stress XS1 YS1 XS2 YS2
Layer (Pcf) (Degree) (Psf) (Psi) (ft) (ft) (ft) (ft)
1 120.0 36.0 150.0 15.0 0.0 0.0 0.0 0.0
* Bond Stress also depends on BSF Factor in Option #5 when enabled.
:�
File: PURC-3
------ WATER SURFACE ---------
NO Water Table defined for this problem.
--------- SEARCH LIMIT ---------
The Search Limit is from 1.0 to 50.0 ft
You have chosen NOT TO LIMIT the search of failure planes
to specific nodes.
--------- REINFORCEMENT PARAMETERS ---------
Number of Reinforcement Levels
Horizontal Spacing
Yield Stress of Reinforcement
Diameter of Grouted Hole
Punching Shear
= 6
= 6.0 ft
= 97.0 ksi
= 3.0 in
= 35.0 kips
---------- (Varying Reinforcement Parameters) ---------
Vertical Bar
Level Length Inclination Spacing Diameter Bond Stress
(ft) (degrees) (ft) (in) Factor
1 20.0 10.0 1.0 1.00 1.00
2 20.0 10.0 5.0 1.00 1.00
3 15.0 10.0 5.0 1.00 1.00
4 15.0 10.0 5.0 1.00 1.00
5 0.0 0.0 0.0 0.00 0.00
6 0.0 0.0 0.0 0.00 0.00
Page - 2
File: PURC-3 Page - 3
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
� FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
Toe 3.291 6.5 50.2 8.1 84.9 14.6
Reinf. Stress at Level 1= 33.106 Ksi (Pullout controls...)
2 = 33.127 Ksi (Pullout controls...)
3 = 22.348 Ksi (Pullout controls...)
4 = 28.115 Ksi (Pullout controls...)
5 = 0.000 Ksi
6 = 0.000 Ksi
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
' SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 2
2,2gg 11.3 47.8 15.2 84.3 11.3
Reinf. Stress at Level 1= 23.157 Ksi (Pullout controls...)
2 = 23.299 Ksi (Pullout controls...)
3 = 20.021 Ksi (Pullout controls...)
4 = 27.758 Ksi (Pullout controls...)
5 = 0.000 Ksi
6 = 0.000 Ksi
' MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
� (ft) (deg) (ft) (deg) (ft)
NODE 3
2.000 16.2 40.6 14.9 71.6 15.4
Reinf. Stress at Level 1= 17.306 Ksi (Pullout controls...)
2 = 19.848 Ksi (Pullout controls...)
3 = 16.714 Ksi (Pullout controls...)
4 = 26.518 Ksi (Pullout controls...)
5 = 0.000 Ksi
6 = 0.000 Ksi
�
L.
File: PURC-3
MINIMUM
SAFETY
FACTOR
DISTANCE LOWER FAILURE
BEHIND PLANE
WALL TOE ANGLE LENGTH
(ft) (deg) (ft)
UPPER FAILURE
PLANE
ANGLE LENGTH
(deg) (ft)
NODE 4
1.784 21.0 39.6 16.3 61.7 17.7
Reinf. Stress at Level 1= 12.946 Ksi (Pullout controls...)
2 = 17.455 Ksi (Pullout controls...)
3 = 16.171 Ksi (Pullout controls...)
4 = 26.314 Ksi (Pullout controls...)
5 = 0.000 Ksi
6 = 0.000 Ksi
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 5
1.693 25.8 37.2 22.7 60.6 15.8
Reinf. Stress at Level 1= 5.485 Ksi (Pullout controls...)
2 = 14.781 Ksi (Pullout controls...)
3 = 14.911 Ksi (Pullout controls...)
4 = 25.842 Ksi (Pullout controls...)
5 = 0.000 Ksi
6 = 0.000 Ksi
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 6
1.644 30.7 29.0 17.5 52.3 25.1
Reinf. Stress at Level 1= 2.479 Ksi (Pullout controls...)
2 = 9.092 Ksi (Pullout controls...)
3 = 9.560 Ksi (Pullout controls...)
4 = 23.835 Ksi (Pullout controls...)
5 = 0.000 Ksi
6 = 0.000 Ksi
Page - 4
�.
0
J
File: PURC-3
MINIMUM
SAFETY
FACTOR
DISTANCE LOWER FAILURE
BEHIND PLANE
WALL TOE ANGLE LENGTH
(ft) (deg) (ft)
UPPER FAILURE
PLANE
ANGLE LENGTH
(deg) (ft)
NODE 7
1.623 35.5 31.7 16.7 43.8 29.5
Reinf. Stress at Level 1= 1.966 Ksi (Pullout controls...)
2 = 10.810 Ksi (Pullout controls...)
3 = 11.473 Ksi (Pullout controls...)
4 = 24.552 Ksi (Pullout controls...)
5 = 0.000 Ksi
6 = 0.000 Ksi
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 8
1.638 40.3 29.8 18.6 41.8 32.4
Reinf. Stress at Level 1= 0.000 Ksi
2 = 8.055 Ksi (Pullout controls...)
3 = 10.183 Ksi (Pullout controls...)
4 = 24.069 Ksi (Pullout controls...)
5 = 0.000 Ksi
6 = 0.000 Ksi
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 9
• 1.669 45.2 28.4 20.5 40.1 35.4
Reinf. Stress at Level 1= 0.000 Ksi
2 = 5.574 Ksi (Pullout controls...)
3 = 9.118 Ksi (Pullout controls...)
4 = 23.669 Ksi (Pullout controls...)
5 = 0.000 Ksi
6 = 0.000 Ksi
Page - 5
�
File: PURC-3
MINIMUM
SAFETY
FACTOR
DISTANCE LOWER FAILURE
BEHIND PLANE
WALL TOE ANGLE LENGTH
(ft) (deg) (ft)
UPPER FAILURE
PLANE
ANGLE LENGTH
(deg) (ft)
NODE10
1.706 50.0 24.6 16.5 38.2 44.5
Reinf. Stress at Level 1= 0.000 Ksi
2 = 4.404 Ksi (Pullout controls...)
3 = 5.862 Ksi (Pullout controls...)
4 = 22.448 Ksi (Pullout controls...)
5 = 0.000 Ksi
6 = 0.000 Ksi
Page - 6
********************************************************************
* For Factor of Safety = 1.0 *
* Maximum Average Reinforcement Workinq Force: *
* 0.000 Kips/level *
********************************************************************
File: PURF-5
***************************************************
* CALIFORNIA DEPARTMENT OF TRANSPORTATION *
* ENGINEERING SERVICE CENTER *
� * DIVISION OF MATERIALS AND FOUNDATIONS *
* Office of Roadway Geotechnical Engineering *
* Date: 06-14-2006 Time: 10:27:26 *
***************************************************
Project Identification - PURCHASE_30'_Soil Nailed Wall
--------- WALL GEOMETRY ---------
Vertical Wall Height = 30.0 ft
Wall Batter = 5.0 degree
Angle Length
(Deg) (Feet)
First Slope from Wallcrest. = 20.0 24.0
Second Slope from ist slope. = 10.0 12.0
Third Slope from 2nd slope. = 20.0 20.0
Fourth Slope from 3rd slope. = 0.0 0.0
Fifth Slope from 3rd slope. = 0.0 0.0
Sixth Slope from 3rd slope. = 0.0 0.0
Seventh Slope Angle. = 0.0
--------- SLOPE BELOW THE WALL ---------
There is NO SLOPE BELOW THE TOE of the wall
- --------- SURCHARGE ---------
There is NO SURCHARGE imposed on the system.
--------- OPTION #1 ---------
Factored Punching shear, Bond & Yield Stress are used.
Page - 1
--------- SOIL PARAMETERS ---------
Unit Friction Cohesion Bond* Coordinates of Boundary
Soil Weight Angle Intercept Stress XS1 YS1 XS2 YS2
Layer (Pcf) (Degree) (Psf) (Psi) (ft) (ft) (ft) (ft)
1 120.0 36.0 150.0 15.0 0.0 0.0 0.0 0.0
* Bond Stress also depends on BSF Factor in Option #5 when enabled.
File: PURF-5
--------- WATER SURFACE ---------
NO Water Table defined for this problem.
--------- SEARCH LIMIT ---------
The Search Limit is from 1.0 to 50.0 ft
You have chosen NOT TO LIMIT the search of failure planes
to specific nodes.
--------- REINFORCEMENT PARAMETERS ---------
Number of Reinforcement Levels
Horizontal Spacing
Yield Stress of Reinforcement
Diameter of Grouted Hole
Punching Shear
= 6
= 6.0 ft
= 97.0 ksi
= 3.0 in
= 35.0 kips
---------- (Varying Reinforcement Parameters) ---------
Vertical Bar
Level Length Inclination Spacing Diameter Bond Stress
(ft) (degrees) (ft) (in) Factor
1 30.0 10.0 1.0 1.00 1.00
2 30.0 10.0 5.0 1.00 1.00
3 30.0 10.0 5.0 1.00 1.00
4 30.0 10.0 5.0 1.00 1.00
5 30.0 10.0 5.0 1.00 1.00
6 20.0 10.0 5.0 1.00 1.00
Page - 2
�
�
File: PURF-5
MINIMUM
SAFETY
FACTOR
DISTANCE LOWER FAILURE
BEHIND PLANE
WALL TOE ANGLE LENGTH
(ft) (deg) (ft)
UPPER FAILURE
PLANE
ANGLE LENGTH
(deg) (ft)
NODE 4
2.017 21.6 40.5 17.0 71.5 27.2
Reinf. Stress at Level 1= 30.833 Ksi (Pullout controls...)
2 = 33.387 Ksi (Pullout controls...)
3 = 35.942 Ksi (Pullout controls...)
4 = 38.496 Ksi (Pullout controls...)
5 = 47.093 Ksi (Pullout controls...)
6 = 35.330 Ksi (Pullout controls...)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 5
1.825 26.3 39.8 24.0 71.1 24.4
Reinf. Stress at Level 1= 22.289 Ksi (Pullout controls...)
2 = 24.927 Ksi (Pullout controls...)
3 = 27.565 Ksi (Pullout controls...)
4 = 36.629 Ksi (Pullout controls...)
5 = 46.690 Ksi (Pullout controls...)
6 = 35.151 Ksi (Pullout controls...)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 6
1.697 31.0 40.1 24.4 62.2 26.6
Reinf. Stress at Level 1= 18.427 Ksi (Pullout controls...)
2 = 22.841 Ksi (Pullout controls...)
3 = 27.256 Ksi (Pullout controls...)
4 = 36.885 Ksi (Pullout controls...)
5 = 46.855 Ksi (Pullout controls...)
6 = 35.224 Ksi (Pullout controls...)
Page - 4
File: PURF-5
Page - 3
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
Toe 3.526 7.4 40.8 4.9 82.7 28•8
Reinf. Stress at Level 1= 54.158 Ksi (Punching Shear controls..)
2= 53.713 ksi (Punching Shear controls..)
3= 53.269 ksi (Punching Shear controls..)
4= 52.825 ksi (Punching Shear controls..)
5= 52.380 ksi (Punching Shear controls..)
6 = 35.827 Ksi (Pullout controls...)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 2
2.823 12.1 42.7 9.9 79.7 27.2
Reinf. Stress at Level 1= 46.185 Ksi (Pullout controls...)
2 = 47.177 Ksi (Pullout controls...)
3 = 48.170 Ksi (Pullout controls...)
4 = 49.162 Ksi (Pullout controls...)
5 = 50.154 Ksi (Pullout controls...)
6 = 35.853 Ksi (Pullout controls...)
- MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
a (ft) (deg) (ft) (deg) (ft)
NODE 3
2.329 16.8 39.9 11.0 73.3 29.4
Reinf. Stress at Level 1= 38.855 Ksi (Pullout controls...)
2 = 41.060 Ksi (Pullout controls...)
3 = 43.265 Ksi (Pullout controls...)
4 = 45.471 Ksi (Pullout controls...)
5 = 47.676 Ksi (Pullout controls...)
6 = 35.164 Ksi (Pullout controls...)
File: PURF-5
MINIMUM DISTANCE
SAFETY BEHIND
FACTOR WALL TOE
(ft)
LOWER FAILURE
PLANE
ANGLE LENGTH
(deg) (ft)
UPPER FAILURE
PLANE
ANGLE LENGTH
(deg) (ft)
NODE 7
1.655 35.8 36.7 26.8 59.2 28.0
Reinf. Stress at Level 1= 11.891 Ksi (Pullout controls...)
2 = 16.930 Ksi (Pullout controls...)
3 = 22.597 Ksi (Pullout controls...)
4 = 33.703 Ksi (Pullout controls:..)
5 = 44.809 Ksi (Pullout controls...)
6 = 34.315 Ksi (Pullout controls...)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 8
1.617 40.5 34.4 29.5 57.0 29.8
Reinf. Stress at Level 1= 6.128 Ksi (Pullout controls...)
. 2 = 11.661 Ksi (Pullout controls...)
3 = 19.259 Ksi (Pullout controls...)
4 = 31.243 Ksi (Pullout controls...)
5 = 43.228 Ksi (Pullout controls...)
6 = 33.612 Ksi (Pullout controls...)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 9
, 1.594 45.3 32.5 32.2 55.1 31.7
Reinf. Stress at Level 1= 0.811 Ksi (Pullout controls...)
2 = 6.763 Ksi (Pullout controls...)
3 = 16.468 Ksi (Pullout controls...)
4 = 29.187 Ksi (Pullout controls...)
5 = 41.906 Ksi (Pullout controls...)
6 = 33.025 Ksi (Pullout controls...)
Page - 5
File: PURF-5
MINIMUM
SAFETY
*� FACTOR
0
�
DISTANCE LOWER FAILURE
BEHIND PLANE
WALL TOE ANGLE LENGTH
(ft) (deg) (ft)
UPPER FAILURE
PLANE
ANGLE LENGTH
(deg) (ft)
NODE10
1.575 50.0 34.0 24.1 46.4 43.5
Reinf. Stress at Level 1= 4.308 Ksi (Pullout controls...)
2 = 12.425 Ksi (Pullout controls...)
3 = 20.541 Ksi (Pullout controls...)
4 = 30.878 Ksi (Pullout controls...)
5 = 42.993 Ksi (Pullout controls...)
6 = 33.508 Ksi (Pullout controls...)
Page - 6
• ********************************************************************
* For Factor of Safety = 1.0 *
* Maximum Average Reinforcement Working Force: *
* 9.709 Kips/level *
********************************�*****************��*�**************
File: PURD-4
***************************************************
* CALIFORNIA DEPARTMENT OF TRANSPORTATION *
�� * ENGINEERING SERVICE CENTER *
* DIVISION OF MATERIALS AND FOUNDATIONS *
* Office of Roadway Geotechnical Engineering *
* Date: 06-13-2006 Time: 19:54:52 *
***************************************************
Project Identification - PURCHASE_D_40' Soil Nailed Wall
--------- WALL GEOMETRY ---------
Vertical Wall Height = 40.0 ft
Wall Batter = 5.0 degree
Angle Length
(Deg) (Feet)
First Slope from Wallcrest. = 20.0 24.0
Second Slope from ist slope. = 10.0 12.0
Third Slope from 2nd slope. = 20.0 20.0
Fourth Slope from 3rd slope. = 0.0 0.0
Fifth Slope from 3rd slope. = 0.0 0.0
Sixth Slope from 3rd slope. = 0.0 0.0
Seventh Slope Angle. = 0.0
--------- SLOPE BELOW THE WALL ---------
There is NO SLOPE BELOW THE TOE of the wall
' --------- SURCHARGE ---------
There is NO SURCHARGE imposed on the system.
--------- OPTION #1 ---------
Factored Punching shear, Bond & Yield Stress are used.
Page - 1
--------- SOIL PARAMETERS ---------
Unit Friction Cohesion Bond* Coordinates of Boundary
Soil Weight Angle Intercept Stress XS1 YS1 XS2 YS2
Layer (Pcf) (Degree) (Psf) (Psi) (ft) (ft) (ft) (ft)
1 120.0 36.0 150.0 15.0 0.0 0.0 0.0 0.0
* Bond Stress also depends on BSF Factor in Option #5 when enabled.
�
File: PURD-4
--------- WATER SURFACE ---------
NO Water Table defined for this problem.
--------- SEARCH LIMIT ---------
The Search Limit is from 1.0 to 50.0 ft
You have chosen NOT TO LIMIT the search of failure planes
to specific nodes.
--------- REINFORCEMENT PARAMETERS ---
Number of Reinforcement Levels
Horizontal Spacing
Yield Stress of Reinforcement
Diameter of Grouted Hole
Punching Shear
= 8
= 5.0 ft
= 97.0 ksi
= 3.0 in
= 35.0 kips
Page - 2
------=--- (Varying Reinforcement Parameters) ---------
Vertical Bar
Level Lenqth Inclination Spacing Diameter Bond Stress
(ft) (degrees) (ft) (in) Factor
1 40.0 15.0 1.0 1.00 1.00
2 40.0 15.0 5.0 1.00 1.00
3 40.0 15.0 5.0 1.00 1.00
4 40.0 15.0 5.0 1.00 1.00
5 30.0 15.0 5.0 1.00 1.00
6 30.0 15.0 5.0 1.00 1.00
7 30.0 15.0 5.0 1.00 1.00
8 20.0 15.0 5.0 1.00 1.00
File: PURD-4
Page - 3
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
Toe 2.734 8.1 52.0 5.3 82.6 37.8
Reinf. Stress at Level 1= 54.042 Ksi (Punching Shear controls..)
2= 53.579 ksi (Punching Shear controls..)
• 3= 53.117 ksi (Punching Shear controls..)
4= 52.654 ksi (Punching Shear controls..)
5= 52.191 ksi (Punching Shear controls..)
6= 51.729 ksi (Punching Shear controls..)
. 7= 51.266 ksi (Punching Shear controls..)
8 = 38.065 Ksi (Pullout controls...)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 2
2.509 12.8 55.5 15.8 82.8 30.6
Reinf. Stress at Level 1= 63.669 Ksi (Punching Shear controls..)
2= 63.248 ksi (Punching Shear controls..)
3= 62.826 ksi (Punching Shear controls..)
4= 62.405 ksi (Punching Shear controls..)
5 = 47.380 Ksi (Pullout controls...)
- 6 = 48.917 Ksi (Pullout controls...)
_ 7 = 54.590 Ksi (Pullout controls...)
8 = 38.662 Ksi (Pullout controls...)
� MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
. SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 3
2.194 17.4 52.3 22.8 82.6 27.3
Reinf. Stress at Level 1= 57.753 Ksi (Pullout controls...)
2 = 58.202 Ksi (Pullout controls...)
3 = 58.651 Ksi (Pullout controls...)
4 = 59.100 Ksi (Pullout controls...)
5 = 40.636 Ksi (Pullout controls...)
6 = 46.995 Ksi (Pullout controls...)
7 = 53.354 Ksi (Pullout controls...)
8 = 38.113 Ksi (Pullout controls...)
�
File: PURD-4
MINIMUM
SAFETY
FACTOR
DISTANCE LOWER FAILURE
BEHIND PLANE
WALL TOE ANGLE LENGTH
(ft) (deg) (ft)
UPPER FAILURE
PLANE
ANGLE LENGTH
(deg) (ft)
NODE 4
1.968 22.1 46.6 25.7 81.0 28.4
Reinf. Stress at Level 1= 48.929 Ksi (Pullout controls...)
2 = 49.680 Ksi (Pullout controls...)
3 = 50.431 Ksi (Pullout controls...)
4 = 51.182 Ksi (Pullout controls...)
5 = 35.727 Ksi (Pullout controls...)
6 = 43.378 Ksi (Pullout controls...)
7 = 51.028 Ksi (Pullout controls...)
8 = 37.079 Ksi (Pullout controls...)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 5
1.827 26.7 45.9 26.9 74.5 30.1
Reinf. Stress at Level 1= 43.191 Ksi (Pullout controls...)
2 = 45.161 Ksi (Pullout controls...)
3 = 47.131 Ksi (Pullout controls...)
4 = 49.100 Ksi (Pullout controls...)
5 = 35.079 Ksi (Pullout controls...)
6 = 42.900 Ksi (Pullout controls...)
7 = 50.721 Ksi (Pullout controls...)
8 = 36.943 Ksi (Pullout controls...)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 6
1.761 31.4 43.2 21.5 65.5 37.8
Reinf. Stress at Level 1= 39.863 Ksi (Pullout controls...)
2 = 43.537 Ksi (Pullout controls...)
3 = 47.212 Ksi (Pullout controls...)
4 = 50.886 Ksi (Pullout controls...)
5 = 32.961 Ksi (Pullout controls...)
6 = 40.997 Ksi (Pullout controls...)
7 = 49.498 Ksi (Pullout controls...)
8 = 36.399 Ksi (Pullout controls...)
Page - 4
File: PURD-4
MINIMUM DISTANCE
SAFETY BEHIND
FACTOR WALL TOE
(ft)
LOWER FAILIIRE
PLANE
ANGLE LENGTH
(deg) (ft)
UPPER FAILURE
PLANE
ANGLE LENGTH
(deg) (ft)
NODE 7
1.689 36.0 34.7 17.5 61.6 45.5
Reinf. Stress at Level 1= 34.250 Ksi (Pullout controls...)
2 = 38.679 Ksi (Pullout controls...)
3 = 43.109 Ksi (Pullout controls...)
4 = 47.538 Ksi (Pullout controls...)
5 = 30.367 Ksi (Pullout controls...)
6 = 34.796 Ksi (Pullout controls...)
7 = 45.128 Ksi (Pullout controls...)
8 = 34.457 Ksi (Pullout controls...)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 8
1.635 40.7 37.1 25.5 60.5 41.3
Reinf. Stress at Level 1= 27.557 Ksi (Pullout controls...)
2 = 32.206 Ksi (Pullout controls...)
3 = 36.856 Ksi (Pullout controls...)
4 = 41.505 Ksi (Pullout controls...)
5 = 26.075 Ksi (Pullout controls...)
6 = 36.266 Ksi (Pullout controls...)
7 = 46.457 Ksi (Pullout controls...)
8 = 35.047 Ksi (Pullout controls...)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 9
1.591 45.3 35.0 27.7 58.6 43.5
Reinf. Stress at Level 1= 22.268 Ksi (Pullout controls...)
2 = 27.298 Ksi (Pullout controls...)
3 = 32.328 Ksi (Pullout controls...)
4 = 37.358 Ksi (Pullout controls...)
5 = 23.659 Ksi (Pullout controls...)
6 = 34.486 Ksi (Pullout controls...)
7 = 45.312 Ksi (Pullout controls...)
8 = 34.539 Ksi (Pullout controls...)
Page - 5
�:
�
File: PURD-4
MINIMUM
SAFETY
FACTOR
DISTANCE LOWER FAILURE
BEHIND PLANE
WALL TOE ANGLE LENGTH
(ft) (deg) (ft)
UPPER FAILURE
PLANE
ANGLE LENGTH
(deg) (ft)
NODE10
1.560 50.0 33.3 29.9 56.9 45.7
Reinf. Stress at Level 1= 17.247 Ksi (Pullout controls...)
2 = 22.627 Ksi (Pullout controls...)
3 = 28.007 Ksi (Pullout controls...)
4 = 33.387 Ksi (Pullout controls...)
5 = 21.479 Ksi (Pullout controls...)
6 = 32.879 Ksi (Pullout controls...)
7 = 44.280 Ksi (Pullout controls...)
8 = 34.080 Ksi (Pullout controls...)
Page - 6
********************************************************************
* For Factor of Safety = 1.0 *
* Maximum Average Reinforcement Working Force: *
* 13.344 Kips/level *
********************************************************************
TOWN OF VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-213 5
THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
VAIL FIRE DEPARTMENT
OWNER
NOTE
ALARM PERMIT
Job Address: 4418 COLUMBINE DR VAIL
Location.....: 4418 COLUMBINE DRNE-#2
Parcel No...: 210112201009
Project No : �- < <� � - C� � �
APPLICANT
I CONTRACTOR
PURCHASE, JOHN LAYTON
754 E POTATO PATCH DR
VAIL
CO 81657
VAIL ELECTRONICS, LTD.
PO BOX 460
MINTURN
COLORADO 81645,
License: 756-5
VAIL ELECTRONICS, LTD.
PO BOX 460
MINTURN
COLORADO 81645
License: 756-5
02/20/2008
02/20/2008
02/20/2008
Desciption: NEW FIRE ALARM SYSTEM FOR A NEW DUPLEX
Valuation: $2,000.00
Permit #: A08-0011 ��6- (j \Z5p
Status . . . : ISSUED
Applied . . : 02/20/2008
Issued . . : 02/29/2008
Expires . .: 08/27/2008
Phone: 970-949-4121
Phone: (970) 827-9120
Phone: (970) 827-9120
s+*as�**as*r**rt�*ss*sss�*sss*++r*ss*****►**+ssas*s****+s�*a►*s*ss** FEE S UMMARY ***►**ss***+***s*t***s***s******ss**ss*ss�*s**+*s***s****s++
Electrical---------> $ 0. 0 0 Total Calculated Fees--> $ 3 0 7. 0 0
DRB Fee--------> $ o. o o Additional Fees---------> $ o. o 0
Investigation----> $ o. o o Total Permit Fee-------> $ 3 0 �. o 0
W ilI Call--------> S o. 0 o Paymenu-------------> $ 3 0 7. o 0
TOTAL FEES—> $ 3 0 7. 0 0 BALANCE DUE--------> $ 0. 0 0
####t4##ti#####t######*F###i}#####Rt###t##i####f#*###t####*►###*###ti###*##�F*##4#####*######►######it#*►######it####f###i##i4####t�##4##f###i####
Approvals:
Item: 05600 FIRE DEPARTMENT
02/25/2008 DRhoades Action: AP Approved as noted:
1. Heat detector(s) required in all accessible crawlspaces and in all accessible
areas.
2. One set of stamped, approved plans must remain on-site.
3. Other corrections as shown on plans or found during inspections.
###t4K###*#####i###*###i#t4#i#f***##*#}#*##4#4#i##+F####*i###*#t###f##*tR#*####t##*#########*#########t##i###i###########*##Ri#f#t#############*##
CONDITIONS OF APPROVAL
tt#i##*######s#t####t#t#*##i*t#ti###*i#**####tffit##*######i�t######*t##t##*###4/t#st*#►**#t###*##t*##*####*i####/#*#####*####i#t###*##*######if#f*
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOURS IN ADVANfiLr Y T^ ONE A 0-479-2252 FROM 8:00 AM - 5 PM.
FOR HIMSELF AND OWNER
***�*****************************************************************+**********************
TOWN OF VAIL, COLORADO Statement
*****r**�********r*+�********��********�**r****�*******r*�+***********��*******************r
Statement Number: R080000219 Amount: $307.00 02/29/200809:02 AM
Payment Method: Check Init: LC
Notation: #2145/VAIL
ELECTRONICS
-----------------------------------------------------------------------------
Permit No: A08-0011 Type: ALARM PERMIT
Parcel No: 2101-122-0100-9
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE-#2
Total Fees: $307.00
This Payment: $307.00 Total ALL Pmts: $307.00
Balance: $0.00
********************************************��***************************�****************+*
ACCOUNT ITEM LIST:
Account Code
--------------------
BP 00100003111100
PF 00100003112300
Description Current Pmts
------------------------------ ------------
FIRE ALARM PERMIT FEES 75.00
PLAN CHECK FEES 232.00
-----------------------------------------------------------------------------
,�c`-�_"�z :'°�¢se p�-� ��[fi ! �-i~ 6 3=c} �_e'x .Gf? �e e e� i�?s :a; p:,ices{ � j � i xa;�r `e }r.zij` e'-�;�� �� O� lL �
��"� Project #: � U
Buitding Per it #:
Alarm Permit #:
� 970-d79-2135 (Inspections)
���y� TOWN OF VAIL FIRE ALARM PERMIT APPLICATION
f`.nmmPrr_.ial R Rpcirlpntial Firp Alarm chnn �irawinac arP rpn��irpri at timg nf 75 S_
FrQntage Etcf_ a�icatEOCt ��iit�E aetct c�e�t �c� in�cece�atit�c� �e�ted are the Vaits �aloradc�
81�r�7 2'� p�� af this #�rrt�r. A�pl�c�t�4� �.►if� �t�t �e acc�pt�d �.rithcwt this
infnrrr+a+inn
C,S,JMf�Lt t t VALU�i t IUNS f t)K ,PIL/g.KM F�tKMI l 1�abor t� Materiatsi
�
�/� Firc l�iarm; C� I
jl �
'ontact Eagle County Assessors �ce
Parcei # �. � D I I Z� b� d�' 9
Job Name: � • � 2
tF4 t 8 �. �4� ��rn �� r.t� D� .
Legal Description N Lo_ t: � I B�ock: �S S� Filing:
Ov�rners Nampy nt P A,l �dres � e��
t�. N�l o:- F.Q{_ \ 1.::��,'Y QdJ�� % 0
�' Hacares
EngV� �n7�fit� Ji'�c�y��GZ- t. a'u��
Detailed Location of work: (i.e., floor, unit #, bldg. #)
�1� i i ���-
ar visit
for Parcel #
Job Address: �4-� � • ��-�'�m �'" Nt
V'`c� r� ; Gc�.
e
Subdivision: �, �yi�.� ?� K''�pp,
�-1 Phone:
�s� Ph ne: �
io-�3 c-� � �lyo- `�09- q �'
Sc wc-�
Detailed descnpti n of work:
�f.t,'v'� � G�-�- �-�- v�� �J S T'cNV� �a tZ �J -� v� 1�wPQ''`i�
Work Class• New � Addition ( ) Remodel ( ) Repair ( ) Retro-fit ( ) Other ( ) �
Type of Bldg.: Single-family ( ) Twa-family (x) Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( )
No. of Existing �weiling Units in this buiiding: �-
��iVo. af Accommodaiion uniis in this building: I
. , . ,
�ir�s��, a FiS',H, �"1l:gs'cTi rYic;�' 's:,� � i Lri � � �ii i u�r-�. :3 �irF =�'asitiKU r 'ivvir.�n PY1�,1 '°`� •., i 1 �vri � ? v�
OiherFees:
, -.J �u� a �� .�� � ,.�-�� .
� ! � i. C T k ,
�.� . - • -• ■
`e• • -• . • -• ►'�
� ��, � �. i�c� I�f�� Y.�,�
- • , ' r� �
� . i �- i _ _ + ,.
--- - - - _ .
- -,- �_._ - ,�.,
Date
C��d�`-r`�� -
_ ---- .. ---, �
,
-- �t;� "�, ,�
u iI �
I i ` r'
C�� �'��-'__-= �-��.. _
TOWN OF VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2135
VAIL FIRE DEPARTMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT
Job Address: 4418 COLUMBINE DR VAIL
Location.....: 4418 COLUMBINE DRNE-# 1
Parcel No...: 210112201009
Project No : �� � _ 6 �� f�
OWNER PURCHASE, JOHN LAYTON
754 E POTATO PATCH DR
VAIL
CO 81657
APPLICANT VAIL ELECTRONICS, LTD.
PO BOX 460
MINTURN
COLORADO 81645
License: 756-5
CONTRACTOR VAIL ELECTRONICS, LTD.
PO BOX 460
MINTURN
COLORADO 81645
License: 756-5
Permit #
Status . . . :
Applied . . :
Issued . . .
Expires . .:
A08-0012 �'S� _ G \ OO
ISSUED
02/20/2008
02/25/2008
OS/23/2008
02/20/2008 Phone: 970-949-4121
02/20/2008 Phone: (970) 827-9120
02/20/2008 Phone: (970) 827-9120
Desciption: NEW FIRE ALARM SYSTEM FOR A NEW DUPLEX LJNIT #1
Valuation: $2,000.00
**s**�*+**ts+*s**ts********s*ssass*a�a*s****s�s****s**�s�s�**t*s�s#► FEE S UMMARY s****ss*s*ss*a*s**�r*a+*sss*s�as**s****ss*�**s*s*�as*+taa�s*
Electrical--------> $ o. o o Total Calculated Fees--> $ 3 0 �. o 0
DRB Fee--------> $ o. o o Additional Fees--------> $ 0. 0 0
Investigation---> $ o. o o Total Permit Fee-------> $ 3 0 �. o 0
W ill Call---------> $ o. o o Payments----------------> $ 3 0 7. o 0
TOTAL FEES—> $ 3 0 �. 0 o BALANCE DUE-------> $ o. o 0
#t######*►####t####M#ii#i#####*###R�Ft#t�##4/###t*##4*#*###*#*#*#tt*t#**###t######�########ft#R#4#�##4*##M#######**►#######4##i###*#*►t#R##F###*1■
Approvals:
Item: 05600 FIRE DEPARTMENT
02/22/2008 DRhoades Action: AP Approved as noted:
1. Heat detector(s) required in all accessible storage areas and in all accessiblE
crawlspaces.
2. One set of stamped, approved plans must remain on-site.
3. Other corrections as required upon inspection.
ttt*i#+Ft*t*###ft*�F4�F*#########t*####t####t###t###############*t##t#t##t*t####***#it##k*#*#*####***#*#######*##t�F####tf#*#*##f*##############}f##�
CONDITIONS OF APPROVAL
■►t*t#►*►#*#####Mf#######f####i#t#i###R#####!######t#####f##########t**#t#ttet###*#####4########i#t#####*#######*#*####i############i#######f##i4
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOURS IN ADVA�ICE1BYN'ELE}�'H�NE .¢'f 970-479-2252 FROM 8:00 AM - 5 PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
*****�******�**�**�*�******s****************�********************************************�**
TOWN OF VAIL, COLORADO Statement
**********�***»��*****�************�*��****************+***+*��******************�*��*r*****
Statement Number: R080000196 Amount: $307.00 02/25/200811:03 AM
Payment Method: Check Init: DDG
Notation: Vail Alarm DBA
Vail Electronics 2135
-----------------------------------------------------------------------------
Permit No: A08-0012 Type: ALARM PERMIT
Parcel No: 2101-122-0100-9
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE-#1
Total Fees: $307.00
This Payment: $307.00 Total ALL Pmts: $307.00
Balance: $0.00
*****�************�*************�***************�*+***�*********s**�++�************s********
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 FIRE ALARM PERMIT FEES 75.00
PF 00100003112300 PLAN CHECK FEES 232.00
-----------------------------------------------------------------------------
, . APPUCATWN YY{LL NOT BE ACCEPTED !F �OMPLETE OR t1N� 6 D -- , C�� ��
Pro�ect #.
Building Pe it
Alarm Permit #:
970-479-2135 (Inspections)
���p� TOWN OF VAIL FIRE ALARM PERMIT APPLICATION
Commercial � Residential Fire Alarm shop drawings are required at time of 75 S.
Frontage Rd. application s� and must indude i�ormation listied on the Vail, Colorado
81657 2"' page of th� . A►pp�cafion vrill nat be accepted wit �� M ;� e
�r�forrr�ation. D ��-, I 1 i
, d ,���
� l
FEB 2 0 2008 ��
�FOR�►n� � � �
Fire Alarm Contractor. �
��L ���Gi (�n1�1L5
E-Mail Address: �a i �� L R D
Contractor Signature:
Tovm of Vail Reg. No.: Contact
5(�- S !�DI,I
��s I�sIJ, �oM
�
COMPLETE VALUATIONS FOR ALARM PERMIT (Labor � Materiais)
l /
/
. . _ �t=1�L-'�i� � � 1�
�o
Contact E le Coun Assessors Ofirce at 970-328-8640 or visit www.ea le-count .com for Par�' #
Parcel # �/ m/ I 2 a-o / D �
Job Name: � � � � �oLu- m� � N � l�R., '� � Job Address: �'� � � �' �'`��B'�N �
'�G� I l_ Lb�.
Legal Descripfion Lot �j Blodc: C3�'j Filing: Subdivision: �j f�D/�-l�l 3�p, ,
cve+1 N�.� uh-t,1'u,.a�- A � I G-F, �S�'�S Phone:
Engi r: (3 �4- �-4 5 N-�-� E r�. � lt,i.w ��C �2 �3otc I o � 3 Phone' q� a_ � � 9-� o� Z
Detailed Location of work: (i.e., floor, unit #, bldg. #) �a-► cd, . Sc��-3
I� ��r
Detailed description of work:
���S f ��� ft �-A-r�N� S ys ��. M�0 2 N�� ��1�
Woric Class: New (� Addidon ( ) Remodel ( ) Repair ( ) Retro-fit ( ) Other ( )
Type of Btd9.: Sin91e-fa�lY � ) Two-familY �-h�Y � ) Commercia� ( ) Re.Statxarrt � ) d� � )
No_ of Existing Dweffing Units in this b�: No. of Aveomrtwdation �its in ttws bc�:
Does a Fire Alarm Exist: Yes () No ) Does a Fire Sprinkter System Exis#: Yes () No {)
d �.�.�...W _.� ....�. , ;,.w� �-w,., w�.w ,���-�C1�? �����`.� i 1�� [31�i .Y*��x�r���x;e�xx���x��ssx�xx��m���xx�e���
\tVart4latatrrio�etF(1[itutC{pFF7fi�flT�+t/[! FiRRRF[7RR r1(i!'
' e• • —• . • :• !I
' ��ii i _ I � �/ i/ I. /�
�� � � ♦
�. _ r I�
TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
DEPARTMENT OF COMMUNITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ELECTRICAL PERMIT
Job Address: 4418 COLUMBINE DR VAIL
Location.....: 4418 COLUMBINE DRIVE
Parcel No...: 210112201009
Project No : �R�, �_ 6;� 1�
OWNER PURCHASE, JOHN LAYTON
754 E POTATO PATCH DR
VAIL
CO 81657
APPLICANT A-PHASE ELECTRIC, LLC
PO BOX 1564
AVON
CO 81620
License: 313-E
CONTRACTOR A-PHASE ELECTRIC, LLC
PO BOX 1564
AVON
CO 81620
License: 313-E
Permit #: E06-0212
��--o�aa
Status . . . : ISSUED
Applied . . : 10/04/2006
Issued . . . 10/04/2006
Expires . .: 04/02/2007
10/04/2006 Phone: 970-949-4121
10/04/2006 'Phone: 970-845-0188
10/04/2006 Phone: 970-845-0188
Desciption: TEMPORARY POWER
Valuation: $0.00 � Square feet: 50
************************************x***�*********************s**** FEE SUMMARY ************xa********************�****************a********
Electrical---------> $ 51. � 5 Total Calculated Fees--> $ 54 . � 5
DRB Fee---------> $0.0o Additional Fees----------> $0.00
Investigation----> $0. oo Total Permit Fee--------> $54 . 75
Will Call--------> $3 . 00 Payments-----------------> $54 . 75
TOTAL FEES--> � $54.75 BALANCE DUE--------> $0. 00
*******�***s************************�*******************s**s*************s********a****��****************s****************s***********:**********
Approvals:
Item: 06000 ELECTRICAL DEPARTMENT
10/04/2006 shahn Action: AP �
Item: 05600 FIRE DEPARTMENT
*****�***************:*********�****:**********************************.*********.***************�****�*********************�********************
CONDITIONS OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
**..*****.******.***********.******�:*:*:*:*********************************************�*********.************************************:*********
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE TELEPHONE 47 2149 OR AT OUR OFFICE FROM 8:00 AM - 4
PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
********************************************************************************************
TOWN OF VAIL, COLORADO Statement
********************************************************************************************
Statement Number: R060001611 Amount: $54.75 10/04/200603:51 PM
Payment Method: Check Init: DDG
Notation: A-Phase 2138
-----------------------------------------------------------------------------
Permit No: E06-0212 Type: ELECTRICAL PERMIT
Parcel No: 2101-122-0100-9
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE
Total Fees: $54.75
This Payment: $54.75 Total ALL Pmts: $54.75
Balance: $0.00
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code
--------------------
EP 00100003111100
WC 00100003112800
Description
------------------------------
ELECTRICAL PERMIT FEES
WILL CALL INSPECTION FEE
Current Pmts
51.75
3.00
-----------------------------------------------------------------------------
APPLICATION WILL NOT BE ACCEP'TED IF INCOMPLETE OR UNSI �� 8�
Project #: �
�1 �/� E u� g IPP rmi� #:. � �• Ob
. �p (�,r � � � e�� �. I z
��� ' 970-47�-214� (in ons)
75 S. �+omsge Rd.
Vail, Colorado 81657
�'OWN OF VAIL ELECTRICAL PERMIT APPLICATION
CONTRACTOR INFORMATION
COMPLErE SQ. FOOTAGE FOR AREA OF WORK AND VALUATiON OF WORK (Labor 8� Materials)
AMOUNT OF SQ FT IN STRUGTURE: C,'CJ � ELECTRICAL VALUATION:
**w*s*w****w**,r** ***********:**,�*****FOR OFFICE USE ONLY**********************�*******�,.*****
� .
��
�
�
x
j
F:\adev�tMS�PERMIT'S�Buiiding�electical�ermi�l1-23-2005.DOC Page 1 of 2 11/23/2005
TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
DEPARTMENT OF COMMUNITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ELECTRICAL PERMIT
Job Address: 4418 COLUMBINE DR VAIL
Location.....: 4418 COLUMBINE DRNE
Parcel No...: 210112201009
Project No :-� j� S-�j S— 6�F5 �,
OWNER PURCHASE, JOHN LAYTON 09/12/2006
754 E POTATO PATCH DR
VAIL
CO 81657
APPLICANT A-PHASE ELECTRIC, LLC
PO BOX 1564
AVON
CO 81620
Permit #: E06-0163
��- a�6�
Status . . . : ISSUED
Applied . . : 09/12/2006
Issued . . . 10/04/2006
Expires . .: 04/02/2007
Phone: 970-949-4121
09/12/2006 Phone: 970-845-0188
License: 313-E
CONTR.ACTOR A-PHASE ELECTRIC, LLC 09/12/2006 Phone: 970-845-0188
PO BOX 1564
AVON
CO 81620
License: 313-E
Desciption: ELECTRICAL FOR NEW DUPLEX �
Valuation: $0.00 Square feet: 9000
*****x****r***�**************************************************** FEE SUMMARY ************************************************************
Electrical---------> $408 . 25 Total Calculated Fees--> $411.25
DRB Fee---------> $ o. 0 0 Additional Fees----------> $ o. o 0
Investigation----> $0. 00 Total Permit Fee--------> $411.25
Will Call---------> $3 .00 Payments------------------> $411.25
TOTAL FEES--> $411.25 BALANCE DUE--------> $0. 00
***********a�*****************************************************************************************************a****************�************�
Approvals:
Item: 06000 ELECTRICAL DEPARTMENT
09/12/2006 shahn Action: AP
*******************�***«******************************«*******:*************************:**********************************************«*********
CONDITIONS OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
*********************************�:***************�************:********�********:*******************************�**:************�****************
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVA CE BY TELEPH E T 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4
PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
************************************************************************�*******************
TOWN OF VAIL, COLORADO Statement
********************************************************************************************
Statement Number: R060001610 Amount: $411.25 10/04/200603:50 PM
Payment Method: Check Init: DDG
Notation: A-Phase 2138
-----------------------------------------------------------------------------
Permit No: E06-0163 Type: ELECTRICAL PERMIT
Parcel No: 2101-122-0100-9
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE
Total Fees: $411.25
This Payment: $411.25 Total ALL Pmts: $411.25
Balance: $0.00.
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
EP 00100003111100 ELECTRICAL PERMIT FEES 408.25
WC 00100003112800 WILL CALL INSPECTION FEE 3.00
J:n-04�06 W:17va Frar�v� aF r�it cawuNirr u�veta�nr
,���,�►a.�.���
.. Q �
0
�� �
�g S. �lO�t�SRd.
Yail, OolaRado 81657
Yf04ftlZAa� 1•toi r.w iioui rauo
����� �, 0 3 8z�
► � �•
.
� suildn�g Perm➢! �: . �- v c� �
�cal Pere�it �; •
970-47l-2i4� }
«. .� � .-.� .
COMPIIiE �, FOO►TA6E PCR AREA OF 1AlIDRK AND VALtlA'RON OF WORK r�t�
a�ouNraF stt Frn+� s�c�: 1k2� �cn�c�..vu.uanonr. �.
�'� � i��� S / P� � .�p(� Sr .p� � �O a. rr
.t-�.r, _. �.�.odrf-a. _
]ob Neme
�
��
�_`a > / ��
: �����
�
��
- ---- - .
� ,�
�
�
]ob AddRSS: �. ( � �..�E
Subdn�:.
�3��
�
�
!�t'v'
❑�
3
Wotk Clss� N�w Add�lon �) R�nodei ) R�at� ( l Temp i�er (? �( )
warlc'rype: I�ir� y E�eKo�' � i 8�h () Daes aa Etiu r�oist �t �o�dion: Yes () No (
'Iype of e1d�: slr+gfe-�► ( ) D�+o+e+c 4 ) ( ) � � ) tteNaura� ( ) ott�r ( )
No. oP 6dstiryg OwdlDg U� in tfNs buildin9: No. df AoonRmodatfon t� I� thls bWding:
Te fhts nearmft fer a het tril�� Y�s O NO O _
0
a
F: ' .��oos.aoc Z
_ ���i
�
a
�
� P� I
113E OlW.lf� *''"�`"*��
�:r�rmos
6'd 80Z05�80L6 �!�I u4�f a�� LO 90 80 deS
r► .
TOWN OF VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-213 5
VAIL FIRE DEPARTMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
SPRINKLER PERMIT
Job Address: 4418 COLUMBINE DR VAIL
Location.....: 4418 COLUMBINE DRNE-RIGHT SIDE
Parcel No...: 210112201009
Project No : �-�b,j _6 3� �
OWNER PURCHASE, JOHN LAYTON
754 E POTATO PATCH DR
VAIL
CO 81657
APPLICANT ALLIANCE MECHANICAL
P.O. BOX 1855
EAGLE
CO 81631
License: 552-5
CONTRACTOR ALLIANCE MECHANICAL
P.O. BOX 1855
EAGLE
CO 81631
License: 552-S
Permit #
Status . . . .
Applied . . :
Issued . . .
Expires . .:
F07-0119
�6� -a I 6Z5
ISSUED
09/27/2007
O 1 /18/2008
09/27/2007 Phone: 970-949-4121
09/27/2007 Phone: 970-328-0303
09/27/2007 Phone: 970-328-0303
Desciption: East SIDE OF DUPLEX FIRE SPRINKLER SYSTEM
Valuation: $35,000.00
***��a**t***+*+s�s**s*++*****as****a#�a*s*****+a***r►�*sssa***s**+** FEE S UMMARY **+**ss*►****st***trt*�**sr**+**s**«s***s�***a***s******es**
Mechanical---> $ 0. 0 0 Restuarant Plan Review--> $ 0. 0 0 Total Calculated Fees---> $1, 8 3 �. 5 0
Plan Check---> $ 3 5 0. o o DRB Fee---------------------> $ o. o o Additional Fees-----------> S o. o 0
Investigation-> $ o. o o TOTAL FEES--------------> $1, 8 3 �. 5 o Total Permit Fee----------> $1, 8 3 7. 5 0
W ill Call-----> $ o. o o Payments-------------------> S 1, a 3 �. s o
BALANCE DUE---------> $ 0. 0 0
•*+++**.as***s**.s:.•s****.ss*a��**►*s.�.**»*s*+**saas***sa*.as:**s.t+.+as***.+*r�.*r**ss*.*ss�***st*s+ss*:***+sss.«st*.�.+s.:***..sa.ss*+ss�s:sr
Item: 05100 BUILDING DEPARTMENT
Item: 05600 FIRE DEPARTMENT
10/12/2007 DRhoades Action: AP Approved as noted:
1. One set of stamped, approved plans must remain on-site.
2. Accessible crawlspaces may need coverage. Fire Protection Engineer ot record ('.
Matthews ot BFPE) shall be consulted by Alliance Mechanical to determine coverage
locations.
11/05/2007 mcgee Action: AP Crawl space plans approved as submitted.
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
..�...,:.,..+.+......:.*+....+...+.+.......,:�,..*,..*+...#.+.:..:..++.......:*..+.f,:+.*.#.*�:+..*:.:..�..�.::.�........+:�.*....++...:.....+::...*
DECLARATIONS
; I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is conect. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO RS IN ADVANCE BY TELEPHONE AT 970-479-2252
FROM 8:00 AM - 5 PM. _ /
OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
*******+�*********************************+******************+***�**************************
TOWN OF VAIL, COLORADO Statement
************�***�**************+*+**************�**�***********+**�*******++**�****�**���***
Statement Number: R080000074 Amount: $1,837.50 O1/18/200802:28 PM
Payment Method: Check Init: JS
Notation: 6413/ALLIANCE
MECHANICAL
-----------------------------------------------------------------------------
Permit No: F07-0119 Type: SPRINKLER PERMIT
Parcel No: 2101-122-0100-9
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE-RIGHT SIDE
Total Fees: $1,837.50
This Payment: $1,837.50 Total ALL Pmts: $1,837.50
Balance: $0.00
******************�*******************�*�***************************************************
ACCOUNT ITEM LIST:
Account Code
BP 00100003111100
PF 00100003112300
Description
SPRINKLER PERMIT FEES
PLAN CHECK FEES
Current Pmts
1,487.50
350.00
-----------------------------------------------------------------------------
TOJJVN Or` VAIL �FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2135
VAIL FIRE DEPARTMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
SPRINKLER PERMIT Permit #: F07-0120
�_ o�Od
Job Address: 4418 COLUMBINE DR VAIL Status ...: ISSUED
Location.....: 4418 COLUMBINE DRNE-LEFT SIDE Applied ..: 09/27/2007
Parcel No...: 210112201009 Issued ... 03/07/2008
Project No : -�-,�� J � 6 �g � Expires . .:
� �.
OWNER PURCHASE, JOHN LAYTON 09/27/2007 Phone: 970-949-4121
754 E POTATO PATCH DR
VAIL
CO 81657
APPLICANT ALLIANCE MECHANICAL 09/27/2007 Phone: 970-328-0303
P.O. BOX 1855
EAGLE
CO 81631
License: 552-S
CONTRACTOR ALLIANCE MECHANICAL 09/27/2007 Phone: 970-328-0303
P.O. BOX 1855
EAGLE
CO 81631
License: 552-5
Desciption: West SIDE OF DUPLEX FIRE SPRINKLER SYSTEM
Valuation: $35,000.00
a�ss:s*****sa*a**+*sssss****tsss*asa*ss�+f�t**►a*s�**�ss:�s+s*s*t*** FEE S UMMARY **********»**s*s*sar**********s***sss*#*s+rs*t******t*****s•
Mechanical--> $ o. o o Restuarant Plan Review--> $ o. 0 o Total Calculated Fees--->
$1,837.50
Plan Check---> $350. 00 DRB Fee------------------> $0. 00 Additional Fees--------->
$o.00
Investigation-> $ o. 0 0 TOTAL FEES--------------> $1, 8 3 7. 5 0 Total Permit Fee--------> $1, 8 3 �. 5 0
W il I Cal I-----> $ o. o o Paymenu----------- $1, 8 3 �. s o
------->
BALANCE DUE------> $0. 00
##i#t#t#*##ttt####i##F###*###i�##fi#4####►#*#/�if/##*Rt1i###4####�#*##*###R####**###t###**########ft##4#####i*t######►4##t##############t#######t
Item: 05100 BUILDING DEPARTMENT
Item: 05600 FIRE DEPARTMENT
10/25/2007 DRhoades Action: DN BFPE will be resubmitting.
l. No coverage shown in the accessible crawlspaces.
2. Many sprinkler heads are shown too tar ott ot exterior walls tor the 12' x 12'
listed.
3. Reflected ceiling plans not shown.
11/05/2007 mcgee Action: AP Revisions approved as submitted.
Work is subject to field inspection and complaice with Codes.
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
+**a*sst**►sss*a*+*s�s+s***st***s*»a��sssa**s*sa*ra**sssss*ss*sas*ss**a�**s*tst►asasssa�as�ss*****►tss*sss*aa��s�+sasssss**#*�**r*****ss****ssssa
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOUR/,�I ADVANCE BY TELEPHONE AT 970-479-2252
FROM 8:00 AM - 5 PM. i� ,. �
SIGNATURE OF� OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
********�*��*************************.****���********************++*************************
TOWN OF VAIL, COLORADO Statement
****+********��**************�+++*****�***********�***+********************�****+***********
Statement Number: R080000255 Amount: $1,837.50 03/07/200810:11 AM
Payment Method: Check Init: LC
Notation: Alliance
Mechanical Inc 6436
-----------------------------------------------------------------------------
Permit No: F07-0120 Type: SPRINKLER PERMIT
Parcel No: 2101-122-0100-9
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE-LEFT SIDE
Total Fees: $1,837.50
This Payment: $1,837.50 Total ALL Pmts: $1,837.50
Balance: $0.00
****�***+*************+**************r********�***************�*****��******************+***
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 SPRINKLER PERMIT FEES 1,487.50
PF 00100003112300 PLAN CHECK FEES 350.00
-----------------------------------------------------------------------------
Entries for Item:5600 - FIRE DEPARTMENT 14:03 10/12/2007
Action Comments B Date
AP Approved as noted: DRhoades 10/12/2007
1. One set of stamped, approved plans
must remain on-site.
2. Accessibie crawispaces may need
coverage. Fire Protection Engineer of
record (Perry Matthews of BFPE) shall be
consulted by Alliance Mechanical to
determine covera e needs and locations.
Total Rows: 1
Page 1
�=D7-D��q
�C�� ��IOE.NCE
uN � r R �EAST�
ya�$ Co�um4��E �R
Sep 21 07 10:25a Jessie Reyes 303-933-5904 p.l
BFPE
P.0.80X 1068
WESTMINSTER,
Hydraulics Summary Sheet
COLO 80036-1068
Project Information
�OT 3, BIGHORI\I SUB.
4418 COLUMBII�IE DRIVE
VAIL. COLORADO
Contract No: 07-0730
B�ildinq: HOUSE
System I0: EAST UNIT
Ref. O�auinq No:
Construction: COMBUSTIBLE
Occupancy; RESIDENTIRL
Authorltr;
System I�formotion system TyPe; IJET
Hydraulics Design Criteria
Density: .10 6PM iSqFt
Remote Area: 4HOS SqFt
Sprinkler Coverage: UARIE SqFt
Design Standard: NFPA 13R
' Hazard:
Figure: Curve:
Sprinklers / Nozzles
Monufocturer: TYCO
Model: LFII
Size: 1 i2
K—Factcr: 4. 2
Temperature Rating: 155
'V � L 1"`11� D�pA►i��
���0
^ AAa'�wM M �r�ild l�
��
Tt��
, �
.
��y��, „�„ � uis�,c�'�
J��GESS 2,��'pt^
4
.� --;
�w 17912 �:
-o • �- Gi ; �
� : � 4�
. •
O •
'}�F�'°•.N�..•.G\��,<
�� S��NAL EN
°�l�c / ��
Desiener: JR
Calc By: JR
Oate: 9i21 i07
Hyd�oulics
Information
Dernand...
Spr Req'd Pres: 30.74 PSI
Spr Req'd Flow: 79.97 GPM
Add'I Flows: 0.00 GPM
Hose ot Srce: 0.00 GPM
Totol Flew: 79.97 GPM
Total Pres: 30.74 PSI
Static Elev: 0.00 Ft
Supply...
Water Flow Test
Static: 36.00 PSI
Residual: 13.00 PSI
Oty FlowinA: 585.00 GPM
Elevation: 0.00 Ft
Dofe:-------- Time:--------
By_ CONTRACTOR
Pump Dato
Rated: 100 PSIC� 90 GPM
Boost Pres: 60.89 PSI
Discharee Pres: 60.89 PSI
Discharge Flow: 79.97 GPM
Combined
Static: <NA) PSI
Residual: (NA) PSI
Oty Flowtng: <NR> GPM
Available...
P) 35.42 PSIC� 79.97 GPM
F) 30.74 PSIL� 263.68 GPM
Margln...
Pressure: 4.68 PSI
Flow: 183.71 GPM
mc� DynomTcs Gorporotion
"'�"'C'.dp�T�1992. A1 Rlp�ts R�s�rv�d 7700 HydrOUlics
.-.
�
a
...
m
1
�
N
N
m
�
a
LOT 3, BI GHORN F�N: LOT3BI G2. HYD
SIGMA OYNAMICS CORP. 7700 Suppiy / Demand Graph
50
96
96 Margin
qq Pressure 4.68 PSI
92 Flou 183.71 GPM
90
38
36 •
39
32
30 �
28
26
29
22
20
18
l6
14
•
12
10
6
9
S
2
Q L85
100 200 300 900 500 600 700 B00 900 1000
WaFer Flow (GPM)
System Dernand..
Sprinkler Demand 30.74 PSI C� 79.97 GPM
Additional Flous 0.00 �PM
Hose ac Source 0.00 GPM
Total Demand 30.74 PSI � 79.97 GPM
Woter Supply..
Static 36.00 PSI
Residual 13.00 PSI C� 585.00 GPM
Elevation 0.00 PSI
Booster Pump..
Pump Rating 100.00 PSI � 90.00 GPM
Discharge 60.89 PSI C� 79.97 GPM
Boost 60.89 PSI C� 79.97 GPM
Suction 0.00 PSI C� 79.97 GPM
Sep 21 07 10:25a Jessie Reyes 303-933-5904 p.3
SUBMITTAL SERIAL N0:2016HY1
LOT 3, BIGHORN FN: LOT3BIG2.HYD
4418 COLUMBINE DRIVE
VAIL, COLORADO
LEVEL 8630
FLOW TEST RESULTS
Water Supply
STATIC 36.00 PSI
RESIDUAL 13.00 PSI @ 585.00 GPM
Booster Pump
CHURN 100.00 PSI
RATING 100.00 PSI @ 90.00 GPM
RESIDUAL 65.00 PSI @ 135.00 GPM
CITY PRESSURE AVAILABLE AT 80.0 GPM
SUNIlKARY OF SPRINKLER OUTFLOWS
ACTUAL MINIMUM
SPR FLOW FLOW K-FACTOR PRESSURE
130 20.61 15.00 4.20 24.09
131 20.29 15.00 4.20 23.35
132 19.86 15.00 4.20 22.37
133 19.20 19.20 4.20 20.90
35.42 PSI
TOTAL WATER REQUIRED FOR SYSTEM 79.97 GPM
TOTAL WATER REQUIREMENT 79.97 GPM
PRESSURE REQUIRED AT 0 30.74 PSI
MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.09 PSI
MAXIMUM VELOCITY IN PIPES 14.01 FPS
09-21-2007 PAGE 1
Sep 21 07 10:25a Jessie Reyes 303-933-5904 p.4
SUBMITTAL SERIAL N0:2016HY1
LOT 3, BIGHORN FN: LOT3BIG2.HYD
4418 COLUMBINE DRIVE
VAIL, COLORADO
LEVEL 8630
09-21-2007 PAGE 2
Location Flow Pipe Fittings Equiv Friction Pressure
in Size & Length Loss Summary
From To GPM IN Devices Ft PSI/Ft PSI
33 133 1.055 L 0.50 C=150 PT 20.90 (133)
Q 19.20 F=E F 3.00 PE -0.22
32 33
4
BN
1.055
19.20
BN
------------------
32 132
Q 19.86
31 32DQ 19.20
Q 39.06
------------------
31 131
Q 20.29
30 31DQ 39.06
Q 59.36
------------------
30 130
Q 20.61
15 30DQ 59.36
Q 79.97
14 15
Q 79.97
13 14
Q 79.97
12 13
Q 79.97
1.055
BN
1.291
BN
1.055
BN
1.527
BN
1.055
BN
1.527
FM
1.527
FM
1.527
FM
1.527
FM
T 3.50 0.0777 PF 0.27
L 19.16 C=150 PT 20.95 ( 33)
F=0/E F 3.00 PE 0.00
T 22.16 0.0777 PF 1.72
PT 22.67 ( 32)
L 0.50 C=150 PT 22.37 (132)
F=T F 5.00 PE -0.22
T 5.50 0.0827 PF 0.45
L 9.25 C=150 PT 22.60 ( 32)
F=0/E F 3.00 PE 0.00
T 12.25 0.1081 PF 1.32
PT 23.92 ( 31)
L 1.16 C=150 PT 23.35 (131)
F=T,E F 8.00 PE -0.22
T 9.16 0.0860 PF 0.79
L 9.06 C=150 PT 23.92 ( 31)
F=T F 7.00 PE 0.00
T 16.06 0.1035 PF 1.66
PT 25.58 ( 30)
L 8.16 C=150 PT 24.09 (130)
F=T/2E F 11.00 PE -0.22
T 19.16 0.0886 PF 1.70
L 6.92 C=150 PT 25.57 ( 30)
F=E/T F 11.00 PE 0.00
T 17.92 0.1797 PF 3.22
L 10.00 C=150 PT 28.79 ( 15)
F=E F 4.00 PE 4.33
T 14.00 0.1797 PF 2.52
L 8.43 C=150 PT 35.64 ( 14)
F=T F 7.00 PE 0.00
T 15.43 0.1797 PF 2.77
L 18.16 C=150 PT 38.41 ( 13)
F=2E F 8.00 PE 0.00
T 26.16 0.1797 PF 4.70
Sep 21 07 10:26a Jessie Reyes 303-933-5904 p.5
SUBMITTAL SERIAL N0:2016HY1
LOT 3, BIGHORN
4418 COLUMBINE DRIVE
VAIL, COLORADO
LEVEL 8630
Location Flow Pipe
in Size
From To GPM IN
11 12 1.527
Q 79.97
FM
9 11 1.527
Q 79.97
FM
7 9 1.527
Q 79.97
FR
6 7
FN: LOT3BIG2.HYD
Fittings
&
Devices
L
F=T F
T
L
F=E/T F
T
L
F=E F
T
09-21-2007 PAGE 3
Equiv Friction Pressure
Length Loss Summary
Ft PSI/Ft PSI
10.00 C=150 PT 43.11 ( 12)
7.00 PE 4.33
17.00 0.1797 PF 3.05
12.83 C=150 PT 50.49 ( 11)
11.00 PE 0.00
23.83 0.1797 PF 4.28
9.00 C=150 PT 54.77 ( 9)
4.00 PE 3,.68
13.00 0.1797 PF 2.34
PT 60.89 ( 7)
Q 79.97
PUMP RATED PRESSURE 100.00 PSI
PUMP RATED FLOW 90.00 GPM
DISCHARGE PRESSIJRE 60.89 PSI
PR. AVAIL. @ 79.97 GPM = 100.00 PSI
SUCTION PRESSURE O.UO PSI
5 6
Q
4 5
Q
COMMENT:
3 4
Q
2 3
Q
COMMENT:
1 2
Q
0 1
4
BOOST 60.89
1.527 L 2.00 C=150 PT 0.00 ( 6)
79.97 F=GV F 2.00 PE 0.00
FR T 4.00 0.1797 PF 0.72
1.527 L 25.00 C=999 PT 0.72 ( 5)
79.97 F=0 F 0.00 PE 10.83
FR T 25.00 0.0054 PF 0.14
REDUCED PRESSURE BACKFLOW PSI LOSS SHOWN IN ELEV.
1.527 L 2.00 C=150 PT 11.69 ( 4)
79.97 F=0 F 0.00 PE 0.00
FR T 2.00 0.1797 PF 0.36
1.527 L 23.00 C=999 PT 12.05 ( 3)
79.97 F=0 F 0.00 PE 9.97
FR T 23.00 0.0054 PF 0.12
PRESSURE REDUCING VALVE PSI LOSS SHOWN IN ELEV.
1.527 L 2.00 C=150 PT 22.14 ( 2)
79.97 F=GV/T F 9.00 PE 0.43
FR T 11.00 0.1797 PF 1.98
1.959 L 85.00 C=150 PT 24.55 ( 1)
79.97 F=T,GV,2E F 31.00 PE 0.00
UN T 116.00 0.0534 PF 6.19
Sep 21 07 10:26a Jessie Re�es 303-933-5904 p•6
BFPE
P.O.BOX 1068
WESTMIPISTER.
Hydraulics Summary Sheet
COLO 80036-1068
Project Information
LOT 3. BIGHORN SUB.
4418 COLUMBINE DRIVE
VAIL, COLORADO
Contr act No: 07-D730
Buildi�q: HOUSE
System I0: ERST UNIT
Ref. Drauinq No:
Co�struction: COMBUSTIBLE
Occupancy: RESIDENTIAL
AuN�orlfr:
Systern Information System Type: UET
Hydroulics Design Criteria
Density: .10 GPM iSqFt
Remote Areo: 4HDS SqFt
Sprinkler Coverage: 12X12 SqFt
Design Standord: NFPR 13R
Nozard:
Ftgure: Curve:
Spri�klers / Nozzles
Manufacturer: TYCO
Model: LFII
Size: 1 i2
K—Fac tor: 4 . 2
7emperature Roting: 155
Designer: JR
Calc By: JR
Dote: 9 i 21 i 07
Hyd�aulics
Informotion
Demand...
Spr Req'd Pres: 29.69 PSI
Spr Req'd Flow: 75.05 GPM
Add'I Flows: 0.00 GPM
Hose at Srce: 0.00 GPM
Total Flow: 75.05 GPM
Totai Pres: 29.69 PSI
Static Elev: 0.00 Ft
Supply...
Water Flow Test
Static: 36.00 PSI
Residual: 13.00 PSI
pty Flowing: 585.00 GPM
Elevation: 0.00 Ft
Dote:-------- Time:--------
By: CONTRACTOR
Pump Data
Rated: 100 PSIC� 90 GPM
Boost Pres: 93.74 PSI
Discharge Pres: 93.74 PSI
Dlscharge Flow: 75.05 GPM
� Combtned
Stotic: CNA) PSI
Resldual: CNR) PSI
Qty Flowing: <NA> GPM
Available...
P) 35.46 PSIC� 75.05 GPM
F) 29.69 PSIC� 291.01 GPM
Margin...
Pressure: 5.80 PSI
Flow: 215.96 GPM
Sigmc� �ync�mics Corporatior�
� CopYrlphF 1992. AB faphhs Rec�rv�d
7700 Hydroulics
�
�
a
�
d
L
3
�
�
m
L
a
50
9e
96
99
92
90
38
3b
3S
3�
3f
2E
2�
2�
2;
21
1
1
]
1
1
LOT 3, BI GHORN
FN: LOT3BI G 1. HYD
7700 Sueclv / Demand Graph
SIGMA �YtVAMICS CORP. -
Margin
Pr essur e 5.80 PSI
Flou 215.96 GPM
�
I
I
i
1
�
]
3
5
9 �
2
0
6
9 S
Z t.85
� 100 200 300 900 500 600 700 B00 900 1000
Water Flow (GPM)
System Demand..
Sprinkler Demand 29.69 PSI � 75.05 GPM
Additional Flous 0.00 GPM
Hose at Source 0.00 GPM
Total Oemand 29.69 PSI C� 75.05 6PM
Water Supply..
Static 36.00 PSI
Residual 13.00 PSI � 585.00 GPM
Elevation 0.00 PSI
Booster Pump..
Pump Ratinq 100.00 PSI C� 90.00 GPM
Discharge 93.74 PSI � 75.05 GPM
Boost 93.74 PSI C� 75.05 GPM
Suction 0.00 PSI @ 75.05 GPM .
�
�o
�
N
r
0
. J
r
O
N
�
or
v
r�
N
�
�•
fD
�
�D
�
fD
�
�
O
�
to
�
�
�
tD
O
�
�
v
Sep 21 07 10:26a Jessie Reyes 303-933-5904 p.8
SUBMITTAL SERIAL N0:2016HY1
LOT 3, BIGHORN FN: LOT3BIGI.HYD
4418 COLUMBINE DRIVE
VAIL, COLORADO
LEVEL 8630 �
FLOW TEST RESULTS
Water Supply
STATIC 36.00 PSI
RESIDUAL 13.00 PSI @ 585.00 GPM
Booster Pump
CHURN 100.00 PSI
RATING 10�.00 PSI @ 90.00 GPM
RESIDUAL 65.00 PSI @ 135.00 GPM
CITY PRESSURE AVAILABLE AT 75.1 GPM
SUMMARY OF SPRINKLER OUTFLOWS
ACTUAL MINIMUM
SPR FLOW FLOW K-FACTOR PRESSURE
101 19.61 18.00 4.20 21.80
102 18.94 18.00 4.20 20.33
103 18.51 18.00 4.20 19.42
104 18.00 18.00 4.20 18.37
35.48 PSI
TOTAL WATER REQUIRED FOR SYSTEM 75.05 GPM
TOTAL WATER REQUIREMENT 75.05 GPM
PRESSURE REQUIRED AT 0 29.69 PSI
MAXIMUM PRESSURE UNBALANCE IN LOOPS 0.07 PSI
MAXIMUM VELOCITY IN PIPES 13.15 FPS
09-21-2007 PAGE 1
Sep 21 07 10:27a Jessie Reyes 303-933-5904 P•9
SUBMITTAL SERIAL N0:2016HY1 FN• LOT3BIGI.HYD
LOT 3, BIGHORN •
4418 COLUMBINE DRIVE
VAIL, COLORADO
LEVEL 8630
09-21-2007 PAGE 2
Location Flow Pipe Fittings Equiv Friction Pressure
in Size & Length Loss Summary
From To GPM IN Devices Ft PSI/Ft PSI
27 104 1.055 L 0.50 C=150 PT 18.37 (104)
Q 18.00 F=E F 3.00 PE -0.22
gN T 3.50 0.0689 PF 0.24
2g 2� 1.055 L 9.06 C=150 PT 18.39 ( 27)
Q 18.OU F=T/2E F 11.00 PE -0.22
gN T 20.06 0.0689 PF 1.38 6
26 103 1.055
Q 18.51
BN
25 26DQ 18.00 1.291
Q 36.51
BN
25 102 1.055
Q 18.94
BN
24 25DQ 36.51 1.527
Q 55.45
BN
24 101 1.055
Q 19.61
BN
23 24DQ 55.45 1.527
Q 75.05
BN
22 23 1.527
Q 75.05
FM
21 22 1.527
Q 75.05
FM
20 21 1.527
Q 75.05
FM
PT 19.55 ( 2 )
L, 2.16 C=150 PT 19.42 (103)
F=0/E F 3.00 PE -0.22
T 5.16 0.0726 PF 0.37
L 10.33 C=150 PT 19.57 ( 26)
F=0 F 0.00 PE 0.00
T 10.33 0.0954 PF 0.99
PT 20.56 ( 25)
L 0.50 C=150 PT 20.33 (102)
F=T F 5.00 PE -0.22
T 5.50 0.0757 PF 0.42
L 7.50 C=150 PT 20.53 ( 25)
F=T F 7.00 PE 0.00
T 14.50 0.0912 PT 21.85 ( 24)
i, 2.33 C=150 PT 21.80 (101}
F=0/E F 3.00 PE -0.43
T 5.33 0.0807 PF 0.43
L 1.33 C=150 PT 21.80 ( 24)
F=2E F 8.00 PE -0.07
T 9.33 0.1598 PF 1.49
L 12.16 C=150 PT 23•22 ( 23)
F=E F 4.00 PE 5.27
T 16.16 0.1598 PF 2.58
I,, g,92 C=150 PT 31.07 ( 22)
F=0 F 0.00 PE 0.00
T 8.92 0.1598 PF 1.43
L 4.75 C=150 PT 32.50 ( 21)
F=E F 4.00 PE 0.00
T g.75 0.1598 PF 1.40
Sep 21 07 10:27a Jessie Reyes 303-933-5904 p.10
.
SUBMITTAL SERIAL N0:2016HY1
LOT 3, BIGHORN
4418 COLUMBINE DRIVE
VAIL, COLORADO
LEVEL 8630
Location Flow Pipe Fittings
in Size &
From To GPM IN Devices
19 20 1.527 L
Q 75.05 F=E F
FN: LOT3BIGI.HYD
18 19
Q 75.05
17 18
Q 75.05
16 17
Q 75.05
15 16
Q 75.05
14 15
Q 75.05
13 14
Q 75.05
12 13
Q 75.05
11 12
Q 75.05
9 11
Q 75.05
7 9
Q 75.05
FM 'I'
1.527 L
F=T F
FM T
1.527 L
F=2E,T/E,T F
FN[ T
1.527 L
F=E F
FM 'I'
1.527 L
F=E,T/T,E F
FM 'r
1.527 L
F=E F
FM T
1.527 L
F=T F
FM 'r
1.527 L
F=2E F
FM 'r
1.527 L
F=T F
FM T
1.527 L
F=E/T F
FM Z'
1.527
F=E F
FR T
09-21-2007 PAGE 3
Equiv Friction Pressure
Length Loss Summary
Ft PSI/Ft PSI
10.00 C=150 PT 33.90 ( 20)
4.00 PE 4.33
14.00 0.1598 PF 2.24
1.92 C=150 PT 40.47 ( 19)
7.00 PE 0.00
8.92 0.1598 PF 1.43
29.00 C=150 PT 41.90 ( 18)
26.00 PE 0.00
55.00 0.1598 PF 8.79
10.00 C=150 PT 50.69 ( 17)
4..00 PE 4.33 .
14.00 0.159.8 PF 2.24
19.25 C=150 PT 57.26 ( 16)
22.00 PE 0.00
41.25 0.1598 PF 6.59
10.00 C=150 PT 63.85 ( 15)
4.00 PE 4.33
14.00 0.1598 PF 2.24
8.43 C=150 PT 70.42 ( 14)
7.00 PE 0.00
15.43 0.1598 PF 2.47
18.16 C=150 PT 72.89 ( 13)
8.00 PE 0.00
26.16 0.1598 PF 4.18
10.00 C=150 PT 77.07 ( 12)
7.00 PE 4.33
17.00 0.1598 PF 2.72
12.83 C=150 PT 84.12 ( 11)
11.00 PE 0.00
23.83 0.1598 PF 3.81
L 9.00 C=150 PT 87.93 ( 9)
4.00 PE 3.68
13.00 0.1598 PF 2.08
Sep 21 07�10:27a Jessie Reyes 303-933-5904 p.11
. .
SUBMITTAL SERIAL N0:2016HY1
LOT 3, BIGHORN FN: LOT3BIGI.HYD
4418 COLUMBINE DRIVE
VAIL, COLORADO
LEVEL 8630
Location Flow Pipe Fittings Equiv
in Size & Length
From To GPM IN Devices Ft
6 7 .
Q 75.05
pUMP RATED PRESSURE 100.00 PSI
PUMP RATED FLOW 90.00 GPM
DISCHARGE PRESSURE 93.74 PSI
PR. AVAIL. @ 75.05 GPM = 100.00 PSI
SUCTION PRESSURE 0.00 PSI
09-21-2007 PAGE 4
Friction Pressure
Loss Summary
PSI/Ft PSI
PT 93.74 ( 7)
BOOST 93.74
5 6 1.527 L 2.00 C=150 PT 0.00 ( 6)
Q 75.05 F=GV F 2.00 PE 0.00
FR T 4.00 0.1598 PF 0.64
4 5 1.527 L 25.00 C=999 PT 0.64 ( 5)
Q 75.05 F=0 F 0.00 PE 10.83
FR T 25.00 0.0048 PF 0.12
COMMENT: REDUCED PRESSURE BACKFLOW PSI LOSS SHOWN IN ELEV.
3 4 1.527 L 2.00 C=150 PT 11.59 ( 4)
Q 75.05 F=0 F 0.00 PE 0.00
FR T 2.00 0.1598 PF 0.32
2 3 1.527 L 23.00 C=999 PT 11.91 ( 3)
Q 75.05 F=0 F 0.00 PE 9.97
FR T 23.00 0.0048 PF 0.11
COMMENT: PRESSURE REDUCING VALVE PSI LOSS SHOWN IN ELEV.
1 2 1,527 L 2.00 C=150 PT 21.99 ( 2)
Q 75.05 F=GV/T F 9.00 PE 0.43
FR T 11.00 0.1598 PF 1.76
0 1 1.959 L 85.00 C=150 PT 24.18 ( 1)
Q 75.05 F=T,GV,2E F 31.00 PE 0.00
UN T. 116.00 0.04'75 PF 5.51
PT 29.69 ( 0)
TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
l�[��
Job Address:
Location.....:
Parcel No...:
Legal Description:
Project No :
DEPARTMENT OF COMMUNITY DEVELOPMENT
THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MECHANICAL PERMIT
4418 COLUMBINE DR VAIL
4418 COLUMBINE DRNE
210112201009
-�� os- � � �
OWNER PURCHASE, JOHN LAYTON
754 E POTATO PATCH DR
VAIL
CO 81657
APPLICANT A.L. PLUMBING & HEATING,
PO BOX 716
125 RACHEL LN
BRECKENRIDGE
CO 80424
License: 367-M
CONTRACTOR A.L. PLUMBING & HEATING,
PO BOX 716
125 RACHEL LN
BRECKENRIDGE
CO 80424
! License: 367-M
Permit #:
Status . . . .
Applied . . :
Issued . . .
Expires . .:
M07-0141
'�� -6 �oa
ISSUED
07/ 19/2007
07/20/2007
O 1 / 16/2008
07/19/2007 Phone: 970-949-4121
INC07/19/2007 Phone: 970-453-1090
INC07/19/2007 Phone: 970-453-1090
Desciption: VENTING TO ALL BATH FANS, DRYER VENTS AND RANGE HOODS;
WATER HOSE BIBS
Valuation: $84,000.00
Fireplace Information: Restricted: # of Gas Appliances: 0 � of Gas Logs: 0 # of Wood Pellet: 0
s***s+s+ss*****ssss�ss*****�ss*�******s**********+*+a******�s►*►s*** FEE SUMMARY +k#��F####4t######*+k#######*#f##Mi*##*t####+kt**#f###t###*f###/
Mechanical---> $ i, 6 a o. o o Restuarant Plan Review--> $ o. 0 0 Total Calculated Fees---> $ z, i o 3. o 0
Plan Check--> $ a 2 0. o o TOTAL FEES--------------> $ 2, 10 3. o o Additional Fees-----------> $ o. 0 0
Investigation-> $ 0. 0 o Total Permit Fee---------> $ 2, 10 3. 0 0
W ill Call---> S 3. o o Payments------------------> $ z, 10 3. o 0
BALANCE DUE--------> S 0. 0 0
ssss***fs■s**s*t*�s�s.s*a*vs*ss�s***s:*ts+r�:s*****.ss:*tst*s■s:**►as.*►***r***+;ara**►**+.�r*■t�**.*f*s:***+.t+as***►s*.*:sss*�*:.�*s*fss.**s**t
Item: 05100 BUILDING DEPARTMENT
07/19/2007 cgunion Action: AP
Item: 05600 FIRE DEPARTMENT
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 22
(BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION
304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL.
Cond: 23
(BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND
CHAPTER 10 OF THE 2003 IMC.
Cond: 25
(BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC.
Cond: 29
(BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003
IMC AND CHAPTER 3 OF THE 2003 IFGC..
Cond: 31
(BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS
LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING.
Cond: 32
(BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR
TO AN INSPECTION REQUEST.
Cond: 30
(BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED
MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6.
###*4}##4}�i#tf#*#RSf4�#4####tf###4################4#t#t###t4*##t#4#4*#f###t#t######t#4*#######t#►#t##►*##R##�###*##**#t#�#####*t4#►#####t*#t#k#■
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as reyuired is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approveii, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN AD CE BY TELEPHONE AT 479-21 9 QR AT OUR OFFICE FROM 8:00 AM - 4 PM.
r
/'i( ° `'�,
SIGNATURE OF OWNER OR ONTRACTOR FOR HIMSELF AND OWNER
*********+**********************************************************************************
TOWN OF VAIL, COLORADO Statement
*r*�+*****+*****�+***«************�********r*********+****+****+***********+****************
Statement Number: R070001292 Amount: $2,103.00 07/20/200708:08 AM
Payment Method: Check Init: LT
Notation: A&L Plumbing &
Heating / ck 4382
-----------------------------------------------------------------------------
Permit No: M07-0141 Type: MECHANICAL PERMIT
Parcel No: 2101-122-0100-9
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE
Total Fees: $2,103.00
This Payment: $2,103.00 Total ALL Pmts: $2,103.00
Balance: $0.00
**********�****�****************************�**********************************+************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
MP 00100003111100 MECHANICAL PERMIT FEES 1,680.00
PF 00100003112300 PLAN CHECK FEES 420.00
WC 00100003112800 WILL CALL INSPECTION FEE 3.00
-----------------------------------------------------------------------------
. APP#3GTION VfRLL NOT BE ACCEPTED IF INCOMRLETE t� �L�e�N� `�S' i�3 � Z-
� TOV P�t�.#:
Buildi�r� P�n'►� #: > •
s M O� • b+�/ Mechankat Pertnit �: �-
- i'�t�"� � � ( 9�o-ar.�-2ia9 ����c:+�v�1 ti? t� ( � �
�„� .
...wu�u w� v��■ uc/�u�u*/'��� oC'�Y't'T A�d/ i�"�7TiiN
75 S. FrOnta� Rdd.
Vail, Colorad�► 51657
3�
��
_ P81'fl1� 1111�11 flOt � 8G0@� ilU� #�':�O�M�g�
Prowide INed�ar�al Room Layout drawn �o acale b� indude:
o N1ecl�f Roo�n Dim�
o Combustldn Air Duc* Size and Loartic�t
o Rt�, Ve�rt and G� Line Stze and �L�ocatlon � �.����:;
a #lest L�s Calcs.
o Equip�rt�rt Cut/SPec Sheets
T��nof Vai1 Reg. No.: uor�
^��� '�
.� f�
i� -' � ,� �d. y ^ �/!/�_ ��i�
� �� �� �
�% ��.Sr�
*****�******************� OFFICE USE ONLY*****************************
� F: I�n9�ned�aNca��ermi�l1-23-2005.DOC 11/23/2005
■
■
PLUMBING 8c HEATING, INC.
P,O. Box 716 • BRECKENRIDGE, CoLOr�.DO $0424 ■(970) 453-1090 ■ FAx (970) 453-1092
To: Wynton Development
RE�Lot 3 Bighorn Su ivison, Vail, Co
Plumbing and Mechanic Proposal
Scope of work to include:
All fixtures to be roughed in and installed per plan including waste, vents, hot and cold
water piping.
Gas lines and connections to four fire places, two cook tops and two boilers.
Mechanical venting to all bath fans, dryer vents and range hoods.
Water to two cold water hose bib's, two hot and cold water hose bib's and two ice maker
boxes.
Primary unit to be piped with a one hundred gallon Smart Hot Water maker, secondary
unit, eighty gallon.
Both units to be piped with a hot water re-circulation system with timer con�ol's.
All faucets and fixtures not included.
Bid to include a complete radiant floor heat system with a gyp-crete application, nine
zones in primary unit, seven zones in secondary unit, all zones to have zone pump's,
Triangle Tube boilers, Honeywell products, Grundfos pump's and Wirsbo tubing.
Bid to include, water meter, irrigation pipe and backflow prevetnion and a pressurizer on
each water system.
$ 170,800.00
TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
DEPARTMENT OF COMMUNITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
Job Address:
Location.....:
Parcel No...:
Legal Description:
Project No. :
MECHANICAL PERMIT
4418 COLUMBINE DR VAIL
4418 COLUMBINE DRIVE
210112201009
��d`�j - a3�S�
OWNER PURCHASE, JOHN LAYTON
754 E POTATO PATCH DR
VAIL
CO 81657
APPLICANT RESORT MOUNTAIN ENTERPRISES
P.O. BOX 2032
GLENWOOD SPRINGS
CO 81602
License: 268-M
CONTRACTOR RESORT MOUNTAIN ENTERPRISES
P.O. BOX 2032
GLENWOOD SPRINGS
CO 81602
License: 268-M
03/19/2008
03/19/2008
03/19/2008
Permit #
Status . . . .
Applied . . :
Issued . . .
Expires . ..
M08-0054
�p G _6 � bd
ISSUED
03/19/2008
03/20/2008
09/16/2008
Phone: 970-949-4121
Phone: 970-384-2748
Phone: 970-384-2748
Desciption: INSTALL 2 GAS FIREPLACE APPLIANCFS AND 2 GAS FIREPLACES
WITH GAS LOG SETS
Valuation: $10,000.00
Fireplace Information: Restricted: # of Gas Appliances: 0 ll of Gas Logs: 0 �i of Wood Pellet: 0
*****************x********#*********s*****:***********r*****s******* FEE SUMMARY **s****�s*s**��*****xs**s********r*s*�***as***sa*s**�*******
M���___> $200.0o RestuarantPlanReview--> $0.00 TotalCalculatedFees---> $25a.00
Plan Check---> $ 5 0. 0 0 TOTAL FEES > $ 2 54 . 0 0 Additional Fees--------__ ) $ 0. 0 0
Investi adon-> $0. 00 Total Permit Fee----------> $254 .00
Will Call-----> S4 . 00 Payments------------------> 5254. 00
BALANCE DUE---------> $0. o0
******s�*x*►*****s******�a*******s******ss*****�*****�****s***s****s**s**x*****s�**:�*s************x**ss***�*r**s***s**s*�*****�sr**x*****rsssr:�**
Item: 05100 BUILDING DEPARTMENT
03/19/2008 CG Action: AP
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 22
(BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003
304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL.
Cond: 23
(BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANTJFACTURER'S
CHAPTER 10 OF THE 2003 IMC.
Cond: 25
(BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER
IMC AND SECTION
INSTRUCTIONS AND
5 OF THE 2003 IFGC.
Cond: 29
(BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003
IMC AND CHAPTER 3 OF THE 2003 IFGC..
Cond: 31
(BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS
LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING.
Cond: 32
(BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR
TO AN INSPECTION REQUEST.
Cond: 30
(BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DR.AIN OR OTHER APPROVED
MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6.
******sr.**********«****:****�***.*.***.**�.********s*�******s�*.**�.«s***�*«*�s�********.*********:***********:s�***:****:*s**�r*::******s:*«�**
DECLARATIONS
I hereby acknowledge that I have read this application, iilled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, Intemational Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4
PM. i�J . . .
OF OWNE�R CONTRACTOR FOR HIMSELF AND OWNEF
APPLIGTION WILL NOT BE ACCEP'fED IF IN PLETE OR UNSIGN���� S— -��� Z
TOV Pro)ect #.
�� � � � � Building P�mit #: �+ / n
Mechanical Permit #:
" ' t, ' � 970-479-2149 ilR�ec�orls) �
��� "
75 5. Frontage Rd. .
Vail, ColOrado 81657
/
� : �
�
P"�if1� WI� 110� be aG08�d wl�1011�
Pro�vtde Meci�ankal Room i.ayout drawn to scale t� indude:
o Med� R�oo�n Dln�ensions
o Contbustion Air Duct S'i�e and Location D[� �
o Flues, Vent and Gas Une S�ze and Location
n N�t L� C�
• ' 0 �
t r. -�'. -.� � �e--,a�`�, ���1
�... ;.,� �., �_ .:� �L � e � ,� P�`, . r,
L � - 3 �'�.^�;} ��T' d.., �', c;. �� � �
LL 1 ��� tt � � -� a e� s `vNLr"�':�2,� -?"`� �'s'T'Oy �
.x-.,s �
� .�_- � ' , ,. i ,.-.� k.• h,�r '.
" ` '��.�,�._._ : - ��.N.r�, �
�,�r _:�.___-,�
��.i
. . . __ _..�_ �,.,. i�/zoos
TOWN OF VAIL
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-213 8
DEPARTMENT OF COMMUNITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
PLUMBING PERMIT
Job Address: 4418 COLUMBINE DR VAIL
Location.....: 4418 COLUMBINE DRNE
Parcel No...: 210112201009
Legal Description: �-�� � S _ � 3� �
Project No .
OWNER PURCHASE, JOHN LAYTON 07/19/2007
754 E POTATO PATCH DR
VAIL
CO 81657
APPLICANT A.L. PLUMBING
PO BOX 716
125 RACHEL LN
BRECKENRIDGE
CO 80424
License: 367-P
CONTRACTOR A.L. PLUMBING &
PO BOX 716
125 RACHEL LN
BRECKENRIDGE
CO 80424
License: 367-P
& HEATING, INC07/19/2007
HEATING, INC07/19/2007
Permit #
Status . . . .
Applied . . :
Issued . . .
Expires . .:
P07-0096
�j�4 -05 ( Od
ISSUED
07/19/2007
07/20/2007
01 /16/2008
Phone: 970-949-4121
Phone: 970-453-1090
Phone: 970-453-1090
Desciption: GAS LINES AND COMMECTORS TO FOUR FIItEPLACES, TWO COOKTOPS
AND TWO BOILERS. ALL FIXTURES TO BE ROUGHED IN AND
INSTALLED PER PLAN INCLUDING WASTE VENTS, AND HOT AND COLD
WATER PIPING.
Valuation: $56,000.00
Fireplace Information: Restricted: ?? # of Gas Appliances: ?? # of Gas Logs: ?? # of Wood Pallet ??
*s►s:*++**ss*s*►►*e***s*ass+***s***sss*r*�ss**ss**�a****ss**a*****++* FEE S UMMARY sa***s*+*sss***s***+s**s+s***�****as**s***+f*+*+s**s*s*s+*++
Plumbing---> $ 8 4 0. 0 0 Restuarant Plan Review--> S o. o o Total Calculated Fees---> $1, 0 5 3. o 0
Plan Check---> $ 2 i o. o o TOTAL FEES--------------> $1, 0 5 3. o o Additional Fees-----------> S o. o 0
Investigation-> $ 0. 0 o Total Permit Fee----------> $1, 0 5 3. o 0
Will Call-----> $3.00 Payments-------------------> $1, 053 .00
BALANCE DUE---------> $ o. 0 0
.sss:.s*s■s**.+■s*sss■**st.**t+s***s*****as*sass**�+s.ss:�►*sss**s.at.:ss*■**►.ss:**a■s,*+■s«**fs***ss***ss.*.*.*.ss.*s+�:s.t■+t*+*:s■��*+t:s.s■:
Item: 05100 BUILDING DEPARTMENT
07/19/2007 cgunion Action: AP
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
�t4#i#####tt####ti####*##########i####*t#R####f�#*#i#�t*##i#R#tt######4�F####�M#####*#####t+k##i�**###*t4#t#�t#t##f#►###i####4##f#t#####t!#t*t##s#�F#f#
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN�VANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM.
SIGNAT�JRE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
*****************************************************�****�*********�***********************
TOWN OF VAIL, COLORADO Statement
«*�*********************+*************���*****************++***************************�***+
Statement Number: R070001291 Amount: $1,053.00 07/20/200708:07 AM
Payment Method: Check Init: LT
Notation: AL Plumbing &
Heating / ck 4382
-----------------------------------------------------------------------------
Permit No: P07-0096 Type: PLUMBING PERMIT
Parcel No: 2101-122-0100-9
Site Address: 4418 COLUMBINE DR VAIL
Location: 4418 COLUMBINE DRIVE
Total Fees: $1,053.00
This Payment: $1,053.00 Total ALL Pmts: $1,053.00
Balance: $0.00
**+*********************�****�***********************+�***********�***************�******r**
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300 PLAN CHECK FEES 210.00
PP 00100003111100 PLUMBING PERMIT FEES 840.00
WC 00100003112800 WILL CALL INSPECTION FEE 3.00
-----------------------------------------------------------------------------
APPLICATION WILL NOT BE ACCEPTED IF INCOMPP o' O� �UNS ,
Building Permit #:_
� / Plumbing Permit #: �
��� ;, ,1 � r1 �Q / 970-479-2149 (Inspecl
��P� �V� � V / e0
75 S. Frontage Rd.
Vail, Colorado 81657
TOWN OF VAIL PLUMBING PERMIT APPLICATION
" ��[ bs � � CON�RACTOR INFORMATiON
pl��mhina Contractor: Town of Vail Reg. No.: Contact Person and Phone #'s:
Contractor Signature:
_ 1_/ � � _ � —3/ � .Qv�
�«/'� + ''
F� �:
�Nc%/���5
COMPLETE VALUATION FOR PLUMBING PERNIIT (Labor & Materials)
PLUMBING: $ �GOD
����
� . O/o ��
Q� •�a4,6 �
*******************************�*******
FOR OFFICE USE ONLY*************************************
F:\cdev\FORMS\PERMITS\Building\plumbing�ermit_i1-23-2005.doc Page 1 of 1 11/23/2005
�
�
Hartmann Engineering Inc
1266 Texas Ave
Grand Junction, CO 81501
970-245-6200
March 15, 2007
Community Development Department
75 south Frontage Rd. West
Vail, CO. 81657
Regarding: Tree House by Purchase Development
Dear Sirs:
���-�.'s''
��,
�
� �
�,
�
�
r
Our client, Great Divide Construction Co, has left this project before its completion. We have
provided Engineering Designs for this project to Great Divide Construction. The work will be
done by others employed by Purchase Development.
We have withdrawn from the project and want to withdraw our engineering data and design
drawings. Our design was specifically made for Tom Weber and Great Divide Construction
only. Please return the data and drawings to us as soon as possible.
Thank you for your help.
Hartmann Engineering Inc.
Burt E Hartmann
Colorado Professional Engineer 5374
cc: Tom Weber
Great Divide Construction Company
P O Box 212
Gypsum, CO 81637
-s'
11-21-2008 Inspection Request Reporting Page 1
4'25 �m Vail, CQ - Citv Of
Requested Inspect Date: Monday, November 24, 2008
\ Inspection Area: CG
� Site Address: 4478 COLUMBINE DR VAIL
4418 COLUMBINE DRIVE
A/P/D Information
Activity: 606-0100 Type: B-BUILD Sub Type: NDUP Status: ISSUED
Const Type: 103 Occup ancy: Use: VB Insp Area: CG
Owner: PURCHASE, JOHN LAYT(JN Phone: 970-390-9943
Contractor: PURCHASE DEVELOPMENT, LLC
Phone: 970-328-4226
Description: NEW CONSTRUCTION OF PRIMARY/SECONDARY RESIDENCE
Requested Inspection(s)
Item: 540 BLDG-Final C/O
Requesto�: PURCHASE DEVELOPMENT, LLC
Comments: UNIT A(_NORTH); W/C DAVE 376-5956 - AM REQUEST
Assigned To� GDENCKLA
Requested Time: 10:00 AM
Phone: 970-328-4226
Entered By: SBELLM K
Action: Time Exp:
Comment: e message a 6-5956 David... P ina required prior to requesting a building c.o. request canceled
for today�
Comment: APPROVED C.O. FOR SOUTH UNIT ONLY
SEND CO TO JOHN PURCHASE 1310 GREENHILL CT. VAIL,CO. 81657...
l
6
�-�1��
�
, � � � �� _ ����i �
� � �
�
Inspection Historv
Item: 25 PW-Rough grade "" Approved "*
10/OZ/08 Inspector: cdelles Action:
Comment:
Item: 503 PW-Final driveway grade ** Approved "'
08/04/08 Inspector:. Is Action:
Comment: See Conditons
08/04/08 Inspector: Is Action:
Comment:
Item: 10 BLDG-FOOTING "Approved *"
05/04/07 Inspector: JRM Action:
Comment:
10/11/07 Ins ector: JRM Action:
Comment: AP�ROVED FOOTWERS N/W CORNER
Item: 20 BLDG-Foundation/Steel *" Approved **
05/31/07 Inspector: JRM Action:
Comment: NORTH SIDE OF DUPLEX ONLY AS NOl
EAST SIDE OF NORTH SIDE STILL NEEI
PANELS OFF FOR INSPECTIONS TO D�
06/22/07 Inspe�ctor: JRM Action
Comment: SOUTH SIDE OF DUPLEX FOUNDATION
07/23/07 Inspe�ctor: JRM Action
Comment: CENTER PORTION 3RD LIFT APPROVEI
10/22/07 Inspector: shahn Action
Comment: no one on site in morning. returned at 4:3(
Item: 520 PLAN-ILC Site Plan "` Approved "*
03/20/08 Inspector: RLF Action
Comment:
Item: 30 BLDG-Framing "* Approved ""
03/17/08 Inspector: GCD Action
Comment�
:.� � �
AP APPROVED
COND APPROVED/CONDITIONS
AP APPROVED
PA PARTIAL APPROVAL
LANS.
' LIFT PLEASE LEAVE
50 FOOT FORMS.
APPROVAL
PA PARTIAL APPROVAL
and approved ext entrance.
AP APPROVED
DN DENIED
03/18/08 �nspector: GCD Action: DN DENIED
Comment: 1.ILC READ TO BE SUBMITTED AND APPROVED BY
REPT131 Run Id: 8709
�.,
w"
Item: 50
Item: 60
Item: 70
Continued:
Comment:
03/24/08
Comment:
04/30/08
Comment:
� `.'r,
PLANNING
2.OUTSTANDING ROUGH INSPECTIONS
I' ector. GCD Action: PA PARTIAL APPROVAL
Ti�NIT DENOTED AS WEST SIDE IS APPROVED ADD BLOCKING AS NOTED AT
B NG WALLS CHECK AT INSULATION
Irts� pe tor: GCD Action: CR CORRECTION REQUIRED
1.t�R�VIDE WEB STIFFENER OR ALTERNATE, TO BEAMS IN 2 LOCATIONS PER DETA�L
KING AT BEARING AND AT JOISTS AND FOUNDATION WALL AS REQD PER
10 AND 1 /S13.
ER IN GARAGE AT 3 PLY LVL AND JOISTS.
DECKS NOT INSPECTED EITHER SIDE.
BLDG-Insulation *" Approved "`*
03/18/08 Insp ector: SHANN Action: PI PARTIAL INSPECTION
Comment: INSPECTED THE WOOD BURNER CHASE FOR INSULATION AND VAPOR BARRIER.
04/09/08 Ins ector: shahn Action: PA PARTtAL APPROVAL
Comment: SI�E B ONLY. ENVELOPE INSULATION AND HOT WATER RECIRC OK. RECEIVED
CERTIFICATE FOR FILE.
05/16/08 Inspector: sgremmer Action: AP APPROVED
Comment:
BLDG-Sheetrock Nail '" Approved "*
04/28/08 Inspector: JGG Action: PA PARTIAL APPROVAL
Comment: Drywall screws installed �er code, passed inspection.
BLDG-Misc. Approved
03/17/08 Ins pector: GCD Action: NO NOTIFIED
t� SEE FRAMING
Commen .
03/27/08 Inspector: cdavis Action: NO NOTIFIED
Comment: Elevator Permit Recieved from NWCOG h' t
See Condtions attached to permit in file (cut and pasted to t is en ry)
NWCCOG received 2 permits for residential elevators to be installed at the above address. Town
of Vail permit # 06-0100. One of the elevators exceeds 50 feet of travel by 3 inches. Gene called
the insfall company (Colo. Custom Lifts), and told them they need to come up with a waY� of
decreasm the rise by the 3 inches. They told Gene that I had given approval before I left
NWCCO� I never spoke to them about this issue.
Elevator residential code ha 'y `,tes t t if the home elevator excee� cle�Rise, Speed, or 7�
acity t the elevator the rcial code. �
Th als a�ked if they c I it the p�l' tion for non-code corrtp�iant elev�tor, s'howing
tha the e would be onl. . I told the at w Id be acceptable �tnd that we would
r` mea urQ rise at final ins ion and the elevato v�i Quld fail if if exceeded 50 feet.
� f`� Ge `told the elevator compan� to co�t�ct the buil�'erjto come up with a,cnde compliant saiution.
( �' f
i i`�. F. : �.� ,y..l��� `•,� ' 1...�
�� MHce Syewark �,, � r
Elevatdr I�s ec r - f-� ''
�nrthwest ado C un�(of Goverr�m r�ist
05/22/08
Comment:
Item: 90 BLDG-Final
10/03/08
Comment:
Item: 530
Item: 532
Item: 539
Item: 540
Item: 21
?95 X10 F s . ' r `
?08 Fax ,� `` ,� � , �
� tia�n: A PFIRTIAL APPROVAL
� GCD CREWS�UNDER INDOW. FASTENERS REQD TO BE 6" O.C. ADD
ECTION ADD S
AS NEED TO MAINTAIN SPACIN �
GCD Action: CR CORRECTION REQUIRED
OR BRING GRADE UP TO 30" MAX AT LIVING LEVEL DECK
W-TEMP.rC/O `* Approved "*
08/19/08 Inspector: cdelles Action: AP APPROVED
Comment: Contractor needs to label snowmelt zone witin town ROW
W-FINAL C/O *" Approved *"
09/30/08 Inspector: cdelles Action: AP APPROVED
Comment: ** roved "'
LDG-Final C/O App
09/30/08 Inspector: JRM Action: NO NOTIFIED
Comment: left messa� e at 376-5956 David... PW final required prior to requesting a building c.o. request
canceled for today
10/14/08 Ins ector: JRM Action: PA PARTIAL APPROVAL
Comment: AP�ROVED C.O. FOR SOUTH UNIT ONLY
SEND CO TO JOHN PURCHASE 1310 GREENHILL CT. VAIL,CO. 81657...
AN-ILC Foundation Plan "" Approved "'
_ 03/20/08 Inspector: RLF Action: AP APPROVED
Item: 533 PLAN-TEMP. C/O
08/26/08 Inspector: bgibson Action:
Comment: exterior work not completed
Item: 534 PLAN - FtNAL C/O "" Approved "'
OS/27/08 Inspector: bgibson Action:
Comment: south unit onyl
10l15/08 Inspector:. RLF Action:
Comment: for north side- exterior work incomplete,
11/05/08 Inspector: rlf Action:
REPT131
DN DENIED
PA PARTIAL APPROVAL
CR CORRECTION REQUIRED
AP APPROVED
Run Id: 8709
::
�::
.'
r� �
Continued:
Comment:
Comment:
Item: 560 ELEV-Final
08/19/08
Comment:
north unit also finaled
`*�A�pp roved "'
Inspector: NWCOG
Action: AP APPROVED
REPT131 Run Id: 8709
� 3�
�
10-13-2008 Inspection Request Reporting Page 1
4:25 pm Vail, Cp - Citv Of
Requested Inspect Date: Tuesday, October 14, 2008
Inspection Area: CG
Site Address: 4418 COLUMBINE DR VAIL
4418 COLUMBINE DRIVE
A/P/D Information
Activity: 606-0100 Type: B-BUILD Sub Type: NDUP Status: ISSUED
Const Type: 103 Occup ancy: Use: VB Insp Area: CG
Owner: PURCHASE, JOHN LAYTON Phone: 970-390-9943
Contractor: PURCHASE DEVELOPMENT, LLC Phone: 970-328-4226
Description: NEW CONSTRUCTION OF PRIMARY/SECONDARY RESIDENCE
Requested Inspection(s)
Item: 534 PLAN - FINAL C/O Requested Time: 08:00 AM
Requestor: PURCHASE DEVELOPMENT, LLC Phone: 970-328-4226
Comments: SIDE A(North)-AM IF POSSIBLE OR CALL JOHN PURCHASE 390-9943
Assigned To: BGIBSOIV Entered By: SBELLM K
Action: Time Exp:
Comment: sou urn on y
Item: 90 BLDG-Final Requested Time: 08:00 AM
Requestor: PURCHASE DEVELOPMENT, LLC Phone: 970-328-4226
Comments: SIDE B�South)_AM IF POSSIBLE OR CALL JOHN PURCHASE 390-9943
Assigned To: JMOND AGON Entered By: SBELLM K
Action: i Exp:
Comment: I
ADD GUARD OR BRIN G DE UP TO 30" MAX AT LIVING LEVEL DECK
� �
� � \ � i -_
� � ~ / � � --�
, ;� ; � /
_ � � '" �- / � _ �
� � � , � �'' �; 1
� �� ; � ! ' ; ��� /
� ' ,r� � i � '� ' �-' �', '
� � . G,� i � '� 1
� ���� �� � �� ��
;� �.9-� ' _�
Inspection Historv � ;
Item: 25 PW-10�02/08ralnspecto PPrcd I�les �, Action: AP APPROVED
Comment:
Item: 503 PW-Final driveway grade "" Approv d"
08/04/08 Inspector:. Is Action: AP APPROVED
Comment: See Conditons
08/04/08 Inspector: Is Action: COND APPROVED/CONDITIONS
Comment:
Item: 10 BLDG-FOOTING *" Approved *'
05/04/07 Inspector: JRM Action: AP APPROVED
Comment:
10/11/07 Inspector: JRM Action: PA PARTIAL APPROVAL
Comment: APPROVED FOOTWERS N/W CORNER
Item: 20 BLDG-Foundation/Steel "" Approved ""
05/31/07 Inspector: JRM Action: PA PARTIAL APPROVAL
Comment: NORTH SIDE OF DUPLEX ONLY AS NOTED ON FIELD SET OF PLANS.
EAST SIDE OF NORTH SIDE STILL NEEDS ANOTHER 20 FOOT LIFT PLEASE LEAVE
PANELS OFF FOR INSPECTIONS TO DANGEROUS TO CLIMB 50 FOOT FORMS.
06/22/07 Inspe�ctor: JRM Action: PA PARTIAL APPROVAL
Comment: SOUTH SIDE OF DUPLEX FOUNDATION APPROVED
07/23/07 Inspe�ctor: JRM Action: PA PARTIAL APPROVAL
Comment: CENTER PORTION 3RD LIFT APPROVED
10/22/07 Inspector: shahn Action: PA PARTIAL APPROVAL
Comment: no one on site in morning. returned at 4:30 and approved ext entrance.
REPT131 Run Id: 8555
1
Inspection Request Re�orting
Requested Inspect Date: Friday, October 24, 2008
Inspection Area: CG
Site Address: ��$ COLUMBINE DRIVE�L
A/P/D Information Sub T e NSFR
Activity: M07-0141 Type: B-MECH YP �
Occup ancy: Use:
Const Type: Phone: 970-949-4121
Owner: PURCHASE, JOHN LAYTON
HEATING INC Phone: 970-453-1090
P�no d:i
`I
Status: FINAL
Insp Area: CG
Contractor: A.L. PLUMBING & •
Description: VENTING TO ALL BATH FANS, DRYER VENTS AND RANGE HOODS; WATER HOSE BIBS
Re4uested Inspection(s) Requested Time:
Item: 390 MECH-Final Phone:
Requestor: A.L, P�UMBING & HEATING, INC. Entered By:
Comments: A side, PM requested , two mechancials and one plumbing scheduled
Assigned To: GDENCKLA Time Exp:
Action: ICAL APPR /�
Comment: / �
Comment: SIDE A APPROVED.
�
08:30 AM
376-5956
DGOLDEN K
Inspection HistorY
Item: 200 MECH-Rough "" Approved "" Action: CR CORRECTION REQUIRED
03/17/OS Inspector: GCD
Comment: KITICHEN EXHAUST DUCl' ONLYGNEED INSTRUCT ONS FORSfERMINATIONAUST AND
CORRECTIONS
1.BOILER 1" CLEARANCE TO COMBUSTIBLE REQD.
3.COMBUSTION AIR AND VENT REQD TO BE N SAME ZONE CANNOT EXCEED 100 FEET.
03/18/08 Inspector: SHAHN Action: CR CORRECTION REQUIRED
Comment: BOILER CORRECTIONS APPROVED.
STILL NEED KITCHEN HOOD INSTAR��Uion I�AP APPROVED
03/24/08 Inspector: GCD
Comment: KITCHEN HOOD TERMINATION AAction: AP APPROVED
04/23/08 Inspector: dplace
Comment: add missing nail pl�ates Action: AP APPROVED
04/28/08 Insp ector: SHAHN
Comment: SIDE A(LEF�BOILER VENTING, A�t�onUBAP APPROV�ED
04/28/08 Ins ector: S AHN
Comment: SI�E A(LEF� BATH AND CLOTHES DRYERS, AND KITCHEN HOOD OK.
Item: 310 MECH-Heating "' Approved " Action: PA PARTIAL APPROVAL
08/09/07 fnspector: JRM
Comment: IN FLOOR HEAT FIRST FLOOR O A�ion�R PA PARTIAL APPROVAL
04/08/08 Inspector: shahn
Comment: SIDE A TOP D�C nnRFTi�BING AND ENTRY LEVEL 100# AIR.
05/08/08
Comment:
06/26/08
Comment:
Item: 315 PL�B��j08
Comment:
REPT131
JDED uKivcvvrT. q�ion: AP APPROVED
�tor: JRM
�UNIT IN FLOOR HEAT 100 ActiRonE PA PARTIAL APPROVAL
:tor: SGREMMER
melt for driveway and stairs
Action: NO NOTIFIED
SEE PLUMB PERMIT.
Run Id: 8578
�
10-23-2008 Inspection Request Reporting Page 58
4:30 pm Vail CO Cifi� Of
Requested Inspect Date:
Inspection Area:
Site Address:
A/P/D Informati
Activity: P07-0096 Type: B-PLMB
Const Type Occup ancy:
Owner. PUR E, JOHN LAYTON
Contractor: A.L. PLUMBING & HEATING, INC.
Friday, October 24, 2008
4418 COLUMBINE DR VAIL
4418 COLUMBINE DRIVE
Sub Type: NSFR
Use:
Phone: 970-949-4121
Phone: 970-453-1090
Status: ISSUED
Insp Area: CG
Description: FIXTURES TO BE ROUGHEDRN AND INSTALLED PEREPtAN INCL�U�DING WASTE VENTS AND HOTL
AND COLD WATER PIPING.
Requested Inspection(s)
Item: 290 PLMB-Final Requested Time: 09:30 AM
Requestor: A.L. PLUMBING & HEATING, INC. Phone: 970-453-1090
Comments: A side, PM requested , two mechancials and one plumbing scheduled
Assigned To: GDENCKLA Entered By: DGOLDEN K
Action: Time Ex��
Comment: Z.NO HOT WATER N MASTER SHOWE��TIFIED
Comment: B SIDE SOUTH OK.
Comment: SIDE A NORT
PROVID� BAC LOW CERTIFICATION.
ADJUST SHOWER MIX VALVE TEMP.
BOILER NAMEPLATE INDICATES GREATER THATN 400MBT , SO R TED ROOM IS REQUIRED
AT BUILDING FINAL.
Insaection Historv
Item: 210 PLMB-Underground "" Approved '"
08/01/07 lnspector: JRM
Comment: 6# AIR TEST ON DWV
WATER MAIN 96# AIR TEST
Item: 220 PLMB-Rough/D.W.V. '" Approved ""
03/06/OS Inspe�ctor: SHAHN
Comment: SOUTH SIDE APPROVED.
Item: 230 PLMB-Rough/Water "* Approved **
03/06/OS Inspe�ctor: SHAHN
Comment: SOUTH SIDE 80# AIR
Action: AP APPROVED
Action: PA PARTIAL APPROVAL
Action: PA PARTIAL APPROVAL
HOT WATER AND RECIRC SHALL ABE INSULATED PER IECC.
04/23/08 Inspector: dplace Action: AP APPROVED
Comment: pressure test ap�roved
Item: 240 PLMB-Gas Piping ' Approved ""
03/06/08 lnspe�ctor: SHAHN Action: PA PARTIAL APPROVAL
Comment: SOUTH SIDE BLACK PIPE 35# AIR.
04/23/08 Inspector: dplace Action: AP APPROVED
Comment: pressure test approved
Item: 250
Item: 260
Item: 290
LIul6-Final "` Ap proved *"
08/28/08 Inspector: GCD Action: CR CORRECTION REQUIRED
Comment: 1.ALL BACKFLOW DEVICES REQD TO BE CERTIFIED
2.N0 HOT WATER IN MASTER SHOWER
09/25/08 Ins� ector: SHAHN Action: PA PARTIAL APPROVAL
Comment: B 51DE (SOUTH) OK.
REPT131 Run Id: 8578