HomeMy WebLinkAboutB18-0198_Approved Plans_1528229180.pdf06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
max 4" openings at
open risers (typ)
Hand rail req'd
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCE“ ”
·
·
·
·
·
·
·
“ ”
811
C001GENERAL NOTES & LEGEND06/05/18
FOREST ROAD
ROCKLEDGE ROAD
PARCEL B
PARCEL C
PARCEL A
LOT
LOT 1
RAETHER MINOR SUBDIVISION
∆
∆MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCEC010EXISTING CONDITIONS811
06/05/18
MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCEC050DEMOLITION PLAN811
06/05/18
ROCKL
E
D
G
E
ROAD
FFE=8287.992:12MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCE811
C100GRADING & DRAINAGE PLAN06/05/18
2:12ROCKLEDGE ROADFOREST ROADST-1 MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCE811
C200STORM & UTILITY PLAN06/05/18
ROCKL
E
D
G
E
ROAD
FOREST ROAD
2:12MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCE811“ ”
C300EROSION & SEDIMENT CONTROL PLAN06/05/18
MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCEC301ESC DETAILS06/05/18
MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCEC302ESC DETAILS06/05/18
MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCEC303ESC DETAILS06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
04/20/2018
06/05/18
04/20/2018
06/05/18
04/20/2018
06/05/18
04/20/2018
06/05/18
04/20/2018
06/05/18
04/20/2018
06/05/18
04/20/2018
06/05/18
04/20/2018
06/05/18
06/05/18
PLOTTED BY: Kevin ON: Monday, November 07, 2016 AT: 4:35 PM FILEPATH: P:\2000-2099\2071\Drawings\2071T.dwgEX-PL
EX-PL
EX-PL
EX-PLEX-UEEX-PLFOREST ROAD
ROCKLEDGE ROAD
PARCEL B
∆
∆
PARCEL C
PARCEL A
LOT 12
LOT 13
LOT 1
RAETHER MINOR SUBDIVISION
06/05/18
This house is going to have a fire sprinkler system.
Floor drain should accomodate system testing.
06/05/18
Tripped Electric Inc
Load calculation for 307 Rockledge Vail, CO
220.42 3va x 6,828sqft = 20,484va
1st 3,000va @ 100% = 3,000va
remainder @ 35% = 6,120va
220.44 Receptacle load 6,000va
220.50 Motor load 1,500va
220.51 Heating/Air Conditioning 12,000va (A/C larger)
220.52a Small Appliance 7,200va
220.52b Laundry 3,000va
220.53 Permanently connected appliance 6 x 1,800va = 10,800va @ 75% = 8,100va
220.54 Electric Dryer 7,200va
220.55 Electric Cooking 5,000va
Total VA 59,160
59,160va/240v=246amps
59,160va/208v=285amps
310.15 240v=4/0cu or 300MCM AL
208V=250MCM CU or 400MCM AL
06/05/18
Generated by REScheck-Web Software
Compliance Certificate
Project Rockledge Residence
Energy Code: 2015 IECC
Location: Vail, Colorado
Construction Type: Single-family
Project Type: New Construction
Conditioned Floor Area: 6,828 ft2
Glazing Area 34%
Climate Zone: 6 (9248 HDD)
Permit Date:
Construction Site:
307 Rockledge Road
Vail, Colorado 81657
Owner/Agent: Designer/Contractor:
Mike Suman
Suman Architects
141 East Meadow Drive, Suite 211
Vail, Colorado 81657
michael@sumanarchitects.com
Permit Number:
Compliance: Passes using UA trade-off
4.0% Better Than Code Maximum UA: 1366 Your UA: 1312
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Deck Roof 2: Flat Ceiling or Scissor Truss 176 61.2 0.0 0.023 4
Deck Roof 1: Flat Ceiling or Scissor Truss 312 61.2 10.0 0.019 6
Flat Roof: Flat Ceiling or Scissor Truss 1,839 61.2 18.0 0.016 29
Pitched Roof: Cathedral Ceiling (no attic) 574 60.0 18.0 0.013 7
Wall: Wood Frame, 16" o.c. 6,843 29.8 0.0 0.049 213
Garage Door: Solid Door (under 50% glazing) 162 0.300 49
Glass Door: Glass Door (over 50% glazing) 805 0.350 282
Window: Wood Frame 1,534 0.300 460
Floor: Slab-On-Grade (Heated)
Insulation depth: 4.0'
250 10.0 0.684 171
Basement: Solid Concrete or Masonry
Wall height: 10.8'
Depth below grade: 10.8'
Insulation depth: 10.8'
2,591 10.0 10.0 0.035 91
Project Title: Rockledge Residence
Data filename: Page 1 of10
04/18/18Report date:
06/05/18
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: Rockledge Residence
Data filename: Page 2 of10
04/18/18Report date:
06/05/18
Inspection Checklist
Requirements: 0.0% were addressed directly in the REScheck software
REScheck Software Version : REScheck-Web
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2015 IECC
Section
#
& Req.ID
Pre-Inspection/Plan Review Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
103.1,
103.2
[PR1]1
Construction drawings and
documentation demonstrate
energy code compliance for the
building envelope. Thermal
envelope represented on
construction documents.
Complies
Does Not
Not Observable
Not Applicable
103.1,
103.2,
403.7
[PR3]1
Construction drawings and
documentation demonstrate
energy code compliance for
lighting and mechanical systems.
Systems serving multiple
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
Complies
Does Not
Not Observable
Not Applicable
302.1,
403.7
[PR2]2
Heating and cooling equipment is
sized per ACCA Manual S based
on loads calculated per ACCA
Manual J or other methods
approved by the code official.
Heating:
Btu/hr_____
Cooling:
Btu/hr_____
Heating:
Btu/hr_____
Cooling:
Btu/hr_____
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Rockledge Residence
Data filename: Page 3 of10
04/18/18Report date:
06/05/18
Section
#
& Req.ID
Foundation Inspection Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
402.1.2
[FO1]1
Slab edge insulation R-value. R-_____
Unheated
Heated
R-_____
Unheated
Heated
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.2
[FO3]1
Slab edge insulation
depth/length.
_____ ft _____ ft Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.1
[FO4]1
Conditioned basement wall
insulation R-value. Where interior
insulation is used, verification
may need to occur during
Insulation Inspection. Not
required in warm-humid locations
in Climate Zone 3.
R-_____
R-_____
R-_____
R-_____
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2
[FO5]1
Conditioned basement wall
insulation installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
402.2.9
[FO6]1
Conditioned basement wall
insulation depth of burial or
distance from top of wall.
_____ ft _____ ft Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2.1
[FO11]2
A protective covering is installed
to protect exposed exterior
insulation and extends a
minimum of 6 in. below grade.
Complies
Does Not
Not Observable
Not Applicable
403.9
[FO12]2
Snow- and ice-melting system
controls installed.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Rockledge Residence
Data filename: Page 4 of10
04/18/18Report date:
06/05/18
Section
#
& Req.ID
Framing / Rough-In Inspection Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
402.1.1,
402.3.4
[FR1]1
Door U-factor. U-_____ U-_____ Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
402.1.1,
402.3.1,
402.3.3,
402.5
[FR2]1
Glazing U-factor (area-weighted
average).
U-_____ U-_____ Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.1.3
[FR4]1
U-factors of fenestration products
are determined in accordance
with the NFRC test procedure or
taken from the default table.
Complies
Does Not
Not Observable
Not Applicable
402.4.1.1
[FR23]1
Air barrier and thermal barrier
installed per manufacturer’s
instructions.
Complies
Does Not
Not Observable
Not Applicable
402.4.3
[FR20]1
Fenestration that is not site built
is listed and labeled as meeting
AAMA /WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC
400 that do not exceed code
limits.
Complies
Does Not
Not Observable
Not Applicable
402.4.5
[FR16]2
IC-rated recessed lighting fixtures
sealed at housing/interior finish
and labeled to indicate ≤2.0 cfm
leakage at 75 Pa.
Complies
Does Not
Not Observable
Not Applicable
403.3.1
[FR12]1
Supply and return ducts in attics
insulated >= R-8 where duct is
>= 3 inches in diameter and >=
R-6 where < 3 inches. Supply and
return ducts in other portions of
the building insulated >= R-6 for
diameter >= 3 inches and R-4.2
for < 3 inches in diameter.
Complies
Does Not
Not Observable
Not Applicable
403.3.5
[FR15]3
Building cavities are not used as
ducts or plenums.
Complies
Does Not
Not Observable
Not Applicable
403.4
[FR17]2
HVAC piping conveying fluids
above 105 ºF or chilled fluids
below 55 ºF are insulated to ≥R-
3.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
403.4.1
[FR24]1
Protection of insulation on HVAC
piping.
Complies
Does Not
Not Observable
Not Applicable
403.5.3
[FR18]2
Hot water pipes are insulated to
≥R-3.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
403.6
[FR19]2
Automatic or gravity dampers are
installed on all outdoor air
intakes and exhausts.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Rockledge Residence
Data filename: Page 5 of10
04/18/18Report date:
06/05/18
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Rockledge Residence
Data filename: Page 6 of10
04/18/18Report date:
06/05/18
Section
#
& Req.ID
Insulation Inspection Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
303.1
[IN13]2
All installed insulation is labeled
or the installed R-values
provided.
Complies
Does Not
Not Observable
Not Applicable
402.1.1,
402.2.5,
402.2.6
[IN3]1
Wall insulation R-value. If this is a
mass wall with at least ½ of the
wall insulation on the wall
exterior, the exterior insulation
requirement applies (FR10).
R-_____
Wood
Mass
Steel
R-_____
Wood
Mass
Steel
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.2
[IN4]1
Wall insulation is installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Rockledge Residence
Data filename: Page 7 of10
04/18/18Report date:
06/05/18
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
402.1.1,
402.2.1,
402.2.2,
402.2.6
[FI1]1
Ceiling insulation R-value. R-_____
Wood
Steel
R-_____
Wood
Steel
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
303.1.1.1,
303.2
[FI2]1
Ceiling insulation installed per
manufacturer’s instructions.
Blown insulation marked every
300 ft².
Complies
Does Not
Not Observable
Not Applicable
402.2.3
[FI22]2
Vented attics with air permeable
insulation include baffle adjacent
to soffit and eave vents that
extends over insulation.
Complies
Does Not
Not Observable
Not Applicable
402.2.4
[FI3]1
Attic access hatch and door
insulation ≥R-value of the
adjacent assembly.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
402.4.1.2
[FI17]1
Blower door test @ 50 Pa. <=5
ach in Climate Zones 1-2, and
<=3 ach in Climate Zones 3-8.
ACH 50 =_____ ACH 50 =_____ Complies
Does Not
Not Observable
Not Applicable
403.3.4
[FI4]1
Duct tightness test result of <=4
cfm/100 ft2 across the system or
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in
tests, verification may need to
occur during Framing Inspection.
_____ cfm/100
ft2
_____ cfm/100
ft2
Complies
Does Not
Not Observable
Not Applicable
403.3.3
[FI27]1
Ducts are pressure tested to
determine air leakage with
either: Rough-in test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the system including
the manufacturer’s air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer’s air
handler enclosure.
_____ cfm/100
ft2
_____ cfm/100
ft2
Complies
Does Not
Not Observable
Not Applicable
403.3.2.1
[FI24]1
Air handler leakage designated
by manufacturer at <=2% of
design air flow.
Complies
Does Not
Not Observable
Not Applicable
403.1.1
[FI9]2
Programmable thermostats
installed for control of primary
heating and cooling systems and
initially set by manufacturer to
code specifications.
Complies
Does Not
Not Observable
Not Applicable
403.1.2
[FI10]2
Heat pump thermostat installed
on heat pumps.
Complies
Does Not
Not Observable
Not Applicable
403.5.1
[FI11]2
Circulating service hot water
systems have automatic or
accessible manual controls.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Rockledge Residence
Data filename: Page 8 of10
04/18/18Report date:
06/05/18
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
403.6.1
[FI25]2
All mechanical ventilation system
fans not part of tested and listed
HVAC equipment meet efficacy
and air flow limits.
Complies
Does Not
Not Observable
Not Applicable
403.2
[FI26]2
Hot water boilers supplying heat
through one- or two-pipe heating
systems have outdoor setback
control to lower boiler water
temperature based on outdoor
temperature.
Complies
Does Not
Not Observable
Not Applicable
403.5.1.1
[FI28]2
Heated water circulation systems
have a circulation pump. The
system return pipe is a dedicated
return pipe or a cold water supply
pipe. Gravity and thermos-
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
Complies
Does Not
Not Observable
Not Applicable
403.5.1.2
[FI29]2
Electric heat trace systems
comply with IEEE 515.1 or UL
515. Controls automatically
adjust the energy input to the
heat tracing to maintain the
desired water temperature in the
piping.
Complies
Does Not
Not Observable
Not Applicable
403.5.2
[FI30]2
Water distribution systems that
have recirculation pumps that
pump water from a heated water
supply pipe back to the heated
water source through a cold
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104ºF.
Complies
Does Not
Not Observable
Not Applicable
403.5.4
[FI31]2
Drain water heat recovery units
tested in accordance with CSA
B55.1. Potable water-side
pressure loss of drain water heat
recovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
Complies
Does Not
Not Observable
Not Applicable
403.10.2
[FI12]3
Readily accessible switch on
heaters for swimming pools or
permanent in-ground spas.
Switch operation does not
change heater thermostat
setting. Heater circuit breaker is
installed independent of switch.
Gas-fired heaters equipped with
ignition pilots that are not
continuously burning pilots.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Rockledge Residence
Data filename: Page 9 of10
04/18/18Report date:
06/05/18
Section
#
& Req.ID
Final Inspection Provisions Plans Verified
Value
Field Verified
Value Complies? Comments/Assumptions
403.10.3
[FI19]3
Timer switches or other
automatic preset schedule
control method are installed on
heaters and pumps serving pools
and permanent
Complies
Does Not
Not Observable
Not Applicable
403.10.4
[FI20]3
Outdoor heated pools and
outdoor permanent spas have a
vapor retardant cover.
Complies
Does Not
Not Observable
Not Applicable
404.1
[FI6]1
75% of lamps in permanent
fixtures or 75% of permanent
fixtures have high efficacy lamps.
Does not apply to low-voltage
lighting.
Complies
Does Not
Not Observable
Not Applicable
404.1.1
[FI23]3
Fuel gas lighting systems have
no continuous pilot light.
Complies
Does Not
Not Observable
Not Applicable
401.3
[FI7]2
Compliance certificate posted. Complies
Does Not
Not Observable
Not Applicable
303.3
[FI18]3
Manufacturer manuals for
mechanical and water heating
systems have been provided.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: Rockledge Residence
Data filename: Page 10 of10
04/18/18Report date:
06/05/18
2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
29.80Above-Grade Wall
20.00Below-Grade Wall
10.00Floor
79.20Ceiling / Roof
_______Ductwork (unconditioned spaces):
Glass & Door Rating SHGCU-Factor
0.30Window
0.35Door
Heating & Cooling Equipment Efficiency
_______Heating System:_________________________
_______Cooling System:_________________________
_______Water Heater:___________________________
Name: Date:
Comments
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18
06/05/18