HomeMy WebLinkAboutB18-0198_Approved Plans_1528229180.pdf06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 max 4" openings at open risers (typ) Hand rail req'd 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCE“ ” · · · · · · · “ ” 811 C001GENERAL NOTES & LEGEND06/05/18 FOREST ROAD ROCKLEDGE ROAD PARCEL B PARCEL C PARCEL A LOT LOT 1 RAETHER MINOR SUBDIVISION ∆ ∆MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCEC010EXISTING CONDITIONS811 06/05/18 MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCEC050DEMOLITION PLAN811 06/05/18 ROCKL E D G E ROAD FFE=8287.992:12MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCE811 C100GRADING & DRAINAGE PLAN06/05/18 2:12ROCKLEDGE ROADFOREST ROADST-1 MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCE811 C200STORM & UTILITY PLAN06/05/18 ROCKL E D G E ROAD FOREST ROAD 2:12MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCE811“ ” C300EROSION & SEDIMENT CONTROL PLAN06/05/18 MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCEC301ESC DETAILS06/05/18 MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCEC302ESC DETAILS06/05/18 MARTIN /MARTINC O N S U L T I N G E N G I N E E R S0101 FAWCETT ROAD, SUITE 260, AVON, COLORADO 81620970.926.6007 MARTINMARTIN.COMROCKLEDGE RESIDENCEC303ESC DETAILS06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 04/20/2018 06/05/18 04/20/2018 06/05/18 04/20/2018 06/05/18 04/20/2018 06/05/18 04/20/2018 06/05/18 04/20/2018 06/05/18 04/20/2018 06/05/18 04/20/2018 06/05/18 06/05/18 PLOTTED BY: Kevin ON: Monday, November 07, 2016 AT: 4:35 PM FILEPATH: P:\2000-2099\2071\Drawings\2071T.dwgEX-PL EX-PL EX-PL EX-PLEX-UEEX-PLFOREST ROAD ROCKLEDGE ROAD PARCEL B ∆ ∆ PARCEL C PARCEL A LOT 12 LOT 13 LOT 1 RAETHER MINOR SUBDIVISION 06/05/18 This house is going to have a fire sprinkler system. Floor drain should accomodate system testing. 06/05/18 Tripped Electric Inc Load calculation for 307 Rockledge Vail, CO 220.42 3va x 6,828sqft = 20,484va 1st 3,000va @ 100% = 3,000va remainder @ 35% = 6,120va 220.44 Receptacle load 6,000va 220.50 Motor load 1,500va 220.51 Heating/Air Conditioning 12,000va (A/C larger) 220.52a Small Appliance 7,200va 220.52b Laundry 3,000va 220.53 Permanently connected appliance 6 x 1,800va = 10,800va @ 75% = 8,100va 220.54 Electric Dryer 7,200va 220.55 Electric Cooking 5,000va Total VA 59,160 59,160va/240v=246amps 59,160va/208v=285amps 310.15 240v=4/0cu or 300MCM AL 208V=250MCM CU or 400MCM AL 06/05/18 Generated by REScheck-Web Software Compliance Certificate Project Rockledge Residence Energy Code: 2015 IECC Location: Vail, Colorado Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 6,828 ft2 Glazing Area 34% Climate Zone: 6 (9248 HDD) Permit Date: Construction Site: 307 Rockledge Road Vail, Colorado 81657 Owner/Agent: Designer/Contractor: Mike Suman Suman Architects 141 East Meadow Drive, Suite 211 Vail, Colorado 81657 michael@sumanarchitects.com Permit Number: Compliance: Passes using UA trade-off 4.0% Better Than Code Maximum UA: 1366 Your UA: 1312 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Deck Roof 2: Flat Ceiling or Scissor Truss 176 61.2 0.0 0.023 4 Deck Roof 1: Flat Ceiling or Scissor Truss 312 61.2 10.0 0.019 6 Flat Roof: Flat Ceiling or Scissor Truss 1,839 61.2 18.0 0.016 29 Pitched Roof: Cathedral Ceiling (no attic) 574 60.0 18.0 0.013 7 Wall: Wood Frame, 16" o.c. 6,843 29.8 0.0 0.049 213 Garage Door: Solid Door (under 50% glazing) 162 0.300 49 Glass Door: Glass Door (over 50% glazing) 805 0.350 282 Window: Wood Frame 1,534 0.300 460 Floor: Slab-On-Grade (Heated) Insulation depth: 4.0' 250 10.0 0.684 171 Basement: Solid Concrete or Masonry Wall height: 10.8' Depth below grade: 10.8' Insulation depth: 10.8' 2,591 10.0 10.0 0.035 91 Project Title: Rockledge Residence Data filename: Page 1 of10 04/18/18Report date: 06/05/18 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: Rockledge Residence Data filename: Page 2 of10 04/18/18Report date: 06/05/18 Inspection Checklist Requirements: 0.0% were addressed directly in the REScheck software REScheck Software Version : REScheck-Web Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Pre-Inspection/Plan Review Plans Verified Value Field Verified Value Complies? Comments/Assumptions 103.1, 103.2 [PR1]1 Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. Complies Does Not Not Observable Not Applicable 103.1, 103.2, 403.7 [PR3]1 Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. Complies Does Not Not Observable Not Applicable 302.1, 403.7 [PR2]2 Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_____ Cooling: Btu/hr_____ Heating: Btu/hr_____ Cooling: Btu/hr_____ Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Rockledge Residence Data filename: Page 3 of10 04/18/18Report date: 06/05/18 Section # & Req.ID Foundation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 402.1.2 [FO1]1 Slab edge insulation R-value. R-_____ Unheated Heated R-_____ Unheated Heated Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.2 [FO3]1 Slab edge insulation depth/length. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1 [FO4]1 Conditioned basement wall insulation R-value. Where interior insulation is used, verification may need to occur during Insulation Inspection. Not required in warm-humid locations in Climate Zone 3. R-_____ R-_____ R-_____ R-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [FO5]1 Conditioned basement wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable 402.2.9 [FO6]1 Conditioned basement wall insulation depth of burial or distance from top of wall. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2.1 [FO11]2 A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. Complies Does Not Not Observable Not Applicable 403.9 [FO12]2 Snow- and ice-melting system controls installed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Rockledge Residence Data filename: Page 4 of10 04/18/18Report date: 06/05/18 Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 402.1.1, 402.3.4 [FR1]1 Door U-factor. U-_____ U-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1, 402.3.1, 402.3.3, 402.5 [FR2]1 Glazing U-factor (area-weighted average). U-_____ U-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.3 [FR4]1 U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. Complies Does Not Not Observable Not Applicable 402.4.1.1 [FR23]1 Air barrier and thermal barrier installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable 402.4.3 [FR20]1 Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. Complies Does Not Not Observable Not Applicable 402.4.5 [FR16]2 IC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate ≤2.0 cfm leakage at 75 Pa. Complies Does Not Not Observable Not Applicable 403.3.1 [FR12]1 Supply and return ducts in attics insulated >= R-8 where duct is >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. Complies Does Not Not Observable Not Applicable 403.3.5 [FR15]3 Building cavities are not used as ducts or plenums. Complies Does Not Not Observable Not Applicable 403.4 [FR17]2 HVAC piping conveying fluids above 105 ºF or chilled fluids below 55 ºF are insulated to ≥R- 3. R-_____ R-_____ Complies Does Not Not Observable Not Applicable 403.4.1 [FR24]1 Protection of insulation on HVAC piping. Complies Does Not Not Observable Not Applicable 403.5.3 [FR18]2 Hot water pipes are insulated to ≥R-3. R-_____ R-_____ Complies Does Not Not Observable Not Applicable 403.6 [FR19]2 Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Rockledge Residence Data filename: Page 5 of10 04/18/18Report date: 06/05/18 Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Rockledge Residence Data filename: Page 6 of10 04/18/18Report date: 06/05/18 Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 303.1 [IN13]2 All installed insulation is labeled or the installed R-values provided. Complies Does Not Not Observable Not Applicable 402.1.1, 402.2.5, 402.2.6 [IN3]1 Wall insulation R-value. If this is a mass wall with at least ½ of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). R-_____ Wood Mass Steel R-_____ Wood Mass Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [IN4]1 Wall insulation is installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Rockledge Residence Data filename: Page 7 of10 04/18/18Report date: 06/05/18 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions 402.1.1, 402.2.1, 402.2.2, 402.2.6 [FI1]1 Ceiling insulation R-value. R-_____ Wood Steel R-_____ Wood Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.1.1, 303.2 [FI2]1 Ceiling insulation installed per manufacturer’s instructions. Blown insulation marked every 300 ft². Complies Does Not Not Observable Not Applicable 402.2.3 [FI22]2 Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. Complies Does Not Not Observable Not Applicable 402.2.4 [FI3]1 Attic access hatch and door insulation ≥R-value of the adjacent assembly. R-_____ R-_____ Complies Does Not Not Observable Not Applicable 402.4.1.2 [FI17]1 Blower door test @ 50 Pa. <=5 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. ACH 50 =_____ ACH 50 =_____ Complies Does Not Not Observable Not Applicable 403.3.4 [FI4]1 Duct tightness test result of <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing Inspection. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable 403.3.3 [FI27]1 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer’s air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer’s air handler enclosure. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable 403.3.2.1 [FI24]1 Air handler leakage designated by manufacturer at <=2% of design air flow. Complies Does Not Not Observable Not Applicable 403.1.1 [FI9]2 Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. Complies Does Not Not Observable Not Applicable 403.1.2 [FI10]2 Heat pump thermostat installed on heat pumps. Complies Does Not Not Observable Not Applicable 403.5.1 [FI11]2 Circulating service hot water systems have automatic or accessible manual controls. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Rockledge Residence Data filename: Page 8 of10 04/18/18Report date: 06/05/18 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions 403.6.1 [FI25]2 All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits. Complies Does Not Not Observable Not Applicable 403.2 [FI26]2 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. Complies Does Not Not Observable Not Applicable 403.5.1.1 [FI28]2 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. Complies Does Not Not Observable Not Applicable 403.5.1.2 [FI29]2 Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. Complies Does Not Not Observable Not Applicable 403.5.2 [FI30]2 Water distribution systems that have recirculation pumps that pump water from a heated water supply pipe back to the heated water source through a cold water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104ºF. Complies Does Not Not Observable Not Applicable 403.5.4 [FI31]2 Drain water heat recovery units tested in accordance with CSA B55.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. Complies Does Not Not Observable Not Applicable 403.10.2 [FI12]3 Readily accessible switch on heaters for swimming pools or permanent in-ground spas. Switch operation does not change heater thermostat setting. Heater circuit breaker is installed independent of switch. Gas-fired heaters equipped with ignition pilots that are not continuously burning pilots. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Rockledge Residence Data filename: Page 9 of10 04/18/18Report date: 06/05/18 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions 403.10.3 [FI19]3 Timer switches or other automatic preset schedule control method are installed on heaters and pumps serving pools and permanent Complies Does Not Not Observable Not Applicable 403.10.4 [FI20]3 Outdoor heated pools and outdoor permanent spas have a vapor retardant cover. Complies Does Not Not Observable Not Applicable 404.1 [FI6]1 75% of lamps in permanent fixtures or 75% of permanent fixtures have high efficacy lamps. Does not apply to low-voltage lighting. Complies Does Not Not Observable Not Applicable 404.1.1 [FI23]3 Fuel gas lighting systems have no continuous pilot light. Complies Does Not Not Observable Not Applicable 401.3 [FI7]2 Compliance certificate posted. Complies Does Not Not Observable Not Applicable 303.3 [FI18]3 Manufacturer manuals for mechanical and water heating systems have been provided. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Rockledge Residence Data filename: Page 10 of10 04/18/18Report date: 06/05/18 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value 29.80Above-Grade Wall 20.00Below-Grade Wall 10.00Floor 79.20Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.30Window 0.35Door Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name: Date: Comments 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18 06/05/18