HomeMy WebLinkAboutB18-0216_A101LOWER_1529516713.pdfC
M DTV1/4"=1'-0"
A101
LOWER
LEVEL
Sheet
Scale
04.14.2018
2665
Project
Date
2665 Bald Mountain Road
Lot 9 West
Huffman Duplex
Vail, Colorado2665 Bald Mountain RoadRevision/Issue
Project Name and Address
General Contractor
GILLETTE LLC
CONSTRUCTION
POST OFFICE BOX 5821 888.719.1123
VAIL COLORADO 81658 gillettellc.com
Family Room05.21.2018 Permit Submittal
05.30.2018 Permit Resubmittal
Scale: 1/4"=1'-0"
Lighting1
New 1 Hour Partition
Family Room
Garage 650 SF
Entry
Lower South Bed
Laundry
Relocate 20 Min Door
Relocate Sprinkler Head in New Drop Ceiling
Provide Panasonic FV-04VE1 ERV
Provide Hardwired Smoke/CO Detector
New motion to control existing garage lighting.
Two-Family Residential Zoning Review
Lot Size 31276
Site Coverage Allowed 20% 6255 Proposed Site Coverage No Change
GRFA Allowed 8527 Proposed GRFA No Change
Existing Lower Level (West) 1691 Proposed Lower Level (West) 1960
Existing Main Level (West) 1885 Proposed Main Level (West) 1885
Existing Upper Level (West) 486 Proposed Upper Level (West) 486
Existing Living Square Footage 4062.00 Proposed Living Square Footage 4331
Existing Garage 919 Proposed Garage 650
Existing Parking 5 Proposed Parking 5
Town of Vail Adopted Codes & Standards:
2015 International Residential Code
2012 International Plumbing Code
2015 International Mechanical Code
2012 International Fuel Gas Code
2015 International Fire Code
2015 International Energy Conservation Code
2014 National Electrical Code
2015 Amendments located in Ordinance No. 14, Series 2015
Fire Alarm:
Fire Alarm System to comply with current NFPA 72, NFPA 720, 2015 International Fire Code,
and Vail Fire and Emergency Services fire sprinkler installation standards.
Occupancy Group:
R-3 Residential One and Two Family
Construction Type:
VB
Fire Sprinkler System:
Automatic residential fire sprinkler systems shall be designed and installed in accordance with
NFPA 13D and Vail Fire and Emergency Services fire sprinkler installation standards.
C
LEGEND
CEILING FAN
RECESSED CAN
CEILING SCONCE OR PENDANT
WALL SCONCE
TRACK LIGHTING
STEP LIGHT
CABINET LIGHT
PIER MOUNTED FIXTURE
FLOOR UPLIGHT
RECEPTICAL
FLOOR OUTLET
HALF SWITCHED RECEPTICAL
LOW VOLTAGE SMOKE/CO COMBO
D DIMMER
M MOTION
K KEYPAD
T PRESET TIMER
F FAN CONTROL
24 24 HOUR TIMER
TV RECESSED TV BOX
AC DUCTLESS AC (POWER TO OUTDOOR UNIT)
ENVIRONMENTAL RECOVERY VENTILATOR
Existing 399,000 BTU
Wall Hung, Gas Fired,
Condensing Boiler with
Concentric Vent
Existing
Indirect Fired Water Heater
Upgrade existing smoke/CO detectors to comply with current code throughout the home.
Install outlets per code
self closing
this room is not approved as a sleeping room
06/20/18