Loading...
HomeMy WebLinkAboutB18-0216_A101LOWER_1529516713.pdfC M DTV1/4"=1'-0" A101 LOWER LEVEL Sheet Scale 04.14.2018 2665 Project Date 2665 Bald Mountain Road Lot 9 West Huffman Duplex Vail, Colorado2665 Bald Mountain RoadRevision/Issue Project Name and Address General Contractor GILLETTE LLC CONSTRUCTION POST OFFICE BOX 5821 888.719.1123 VAIL COLORADO 81658 gillettellc.com Family Room05.21.2018 Permit Submittal 05.30.2018 Permit Resubmittal Scale: 1/4"=1'-0" Lighting1 New 1 Hour Partition Family Room Garage 650 SF Entry Lower South Bed Laundry Relocate 20 Min Door Relocate Sprinkler Head in New Drop Ceiling Provide Panasonic FV-04VE1 ERV Provide Hardwired Smoke/CO Detector New motion to control existing garage lighting. Two-Family Residential Zoning Review Lot Size 31276 Site Coverage Allowed 20% 6255 Proposed Site Coverage No Change GRFA Allowed 8527 Proposed GRFA No Change Existing Lower Level (West) 1691 Proposed Lower Level (West) 1960 Existing Main Level (West) 1885 Proposed Main Level (West) 1885 Existing Upper Level (West) 486 Proposed Upper Level (West) 486 Existing Living Square Footage 4062.00 Proposed Living Square Footage 4331 Existing Garage 919 Proposed Garage 650 Existing Parking 5 Proposed Parking 5 Town of Vail Adopted Codes & Standards: 2015 International Residential Code 2012 International Plumbing Code 2015 International Mechanical Code 2012 International Fuel Gas Code 2015 International Fire Code 2015 International Energy Conservation Code 2014 National Electrical Code 2015 Amendments located in Ordinance No. 14, Series 2015 Fire Alarm: Fire Alarm System to comply with current NFPA 72, NFPA 720, 2015 International Fire Code, and Vail Fire and Emergency Services fire sprinkler installation standards. Occupancy Group: R-3 Residential One and Two Family Construction Type: VB Fire Sprinkler System: Automatic residential fire sprinkler systems shall be designed and installed in accordance with NFPA 13D and Vail Fire and Emergency Services fire sprinkler installation standards. C LEGEND CEILING FAN RECESSED CAN CEILING SCONCE OR PENDANT WALL SCONCE TRACK LIGHTING STEP LIGHT CABINET LIGHT PIER MOUNTED FIXTURE FLOOR UPLIGHT RECEPTICAL FLOOR OUTLET HALF SWITCHED RECEPTICAL LOW VOLTAGE SMOKE/CO COMBO D DIMMER M MOTION K KEYPAD T PRESET TIMER F FAN CONTROL 24 24 HOUR TIMER TV RECESSED TV BOX AC DUCTLESS AC (POWER TO OUTDOOR UNIT) ENVIRONMENTAL RECOVERY VENTILATOR Existing 399,000 BTU Wall Hung, Gas Fired, Condensing Boiler with Concentric Vent Existing Indirect Fired Water Heater Upgrade existing smoke/CO detectors to comply with current code throughout the home. Install outlets per code self closing this room is not approved as a sleeping room 06/20/18