Loading...
HomeMy WebLinkAboutZone Check Sheet 4425 Glen Falls Ln_1.pdf PLANNING CHECK SHEET Property Information Property Address 4425 Glen Falls Ln Parcel#s 210112313002 Legal Description Lot 2, Forest Glen Subdivision Development Site Area Ac 0.343 Sq Ft 14,941 Buildable Zoning/ SDD # Low Density Multiple Family/ SDD #27 Forest Glen(Timber Falls) Land Use Designation Medium Density Residential Known Non-Conformities Previous Approvals Hazard Zones Snow Avalanche No Sections 12-12, 12-21, 14-6& 14-7 Debris Flow No Rockfall No Excessive Slopes Yes, on small portion of lot (Site Disturbance 12-21-14) Floodplain Yes Wetlands Y/N Yes (Gore Creek) Creeks, Streams Gore Creek Setback 50' Proposed 51.5' Section 12-14-17 Sidewalks/Trails Public Pedestrians/Fisherman's Easement cuts through back yard,per Forest Glen Subdivision plat. Contact Information Planner/Date Chris Neubecker Owner Contact Info Primary Contact/Owner Gregory Sparhawk, Architect(GPS Designs, LLC) Representative Info 301 Boulder Street, Minturn, CO 81645 gregs@gpsdesigns.com (970) 470-4945 or(425) 495-7241 Project Information Project Description Conceptual Review—250 Addition Land Use Application(s)# DRB 18-0015 DRB 18-0186—Includes using part of the allowed 250 Addition Proposed Uses Single Family Permitted,Conditional, Permitted(Existing) (As defined by Zoning) Prohibited? Date Routed/DRT Meeting Planner Staff Meeting January 30, 2018 Commercial Floor Area Existing None Proposed None Gross Residential Floor Area Total Allowed (Per 4,500 -Existing -Proposed +Credits SDD and plat) (includes 1,000 sf basement) As of 1993 Main Garage Upper Total 1,527 473 1,180 3,180 GRFA Per 3,483.7 3,728.6 New= 245 SF Submitted Plans Total Remaining Remaining 21.4 Remaining (includes the 250 addition used with this applicatio n) 250 or Interior Conversion? 250 Addition(Interior Conversion not allowed unless plat note on GRFA limit is removed,per Sec. 12-15-4 D) Zoning District Standards Setbacks (perimeter) Minimum Front 20' Proposed 35' Projections 14-10-4 Minimum Side 15' Proposed 15' Minimum Side 15' Proposed 15.5' Minimum Rear 20' Proposed 65' Lot Area/Width Minimum 10,000 Existing 14,898 Maximum 4,500 (per SDD; Existing/ 3,023 Site Coverage Site Coverage is Proposed same as GRFA) Building Height Maximum 33' slope Proposed No change Landscaping Minimum 40% Proposed Sections 14-10-8 & 14-10-9 Min. Plant size Proposed Fences Proposed Retaining Walls Max. Height 6 feet Proposed None Sec. 14-6-7 Min. Setback Proposed Driveway Max. Curb-cuts Existing Sections 14-3-1 & 14-3-2 Max-Min Slope 0.5%/ 12% Proposed Max-Min Width Min. 12' Proposed Heated Y/N Drive Material Snow Storage % Proposed Parking Min. Spaces 3 Existing 4 Sections 12-10& 14-5 Min. Loading N/A Proposed Lighting Allowed Proposed No change Section 14-10-7 Waste Management Wildlife Proof/ In garage Screened Section 5-9 Resistant Fences/Screening Required Proposed In garage Sections 14-10-9& 14-10-10 Roof Material Complies Y/N Yes—New DaVinci shake Class A proposed on entire Sections 12-11-3C& 14-10-5 building Building Separation Complies Y/N Section 14-10-6 Adopted View Corridors Complies Y/N Utilities Existing (Location,easements) Section 14-10-10 Grading (Less than 2:1) Need topo map Section 14-6 Gas Meters Development Impact Fees / Employee Housing Yes—Property is within a Special Mitigation Development District Traffic Impact N/A Art In Public Places N/A Density maximum— 1 single family residence,plus 1 caretaker unit. GRFA Maximum 4,500 sq. ft. per plat (includes a minimum 1,000 sq. ft. basement). If basement is not installed, above ground GRFA shall be limited to 3,500 sq. ft. Notes Utility Easement along south property line (approx. 30'wide. Public Pedestrians/Fisherman's Easement cuts through back yard, per Forest Glen Subdivision plat. 100' year floodplain in year yard. 12-15-4: INTERIOR CONVERSIONS: (NOT ELIGIBLE....See Section D below) D. Process: Applications shall be made to the department of community development staff on forms provided by the department. Applications for interior conversions to single-family, two-family, primary/secondary or Interior Conversions multi-family dwelling units located in a special development district(SDD) Year built 1993-1994 pursuant to this section shall also be allowed without amending the GRFA provisions of the SDD. However,properties with GRFA restrictions recorded on the plat for the development shall be regulated according to the plat restrictions unless the plat is modified to remove such restrictions (GRFA is listed on the plat for this subdivision.) 250 Addition used in this application(21.4 sq. ft. remains of total GRFA, including the 250 Addition)