HomeMy WebLinkAboutB18-0067_compliance-report-20180312_154113_680_1521237340.pdf irlA COMcheck Software Version 4.0.8.0 8(1 Interior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: WESTWIND POOL REMODEL Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: VAIL, CO BILL PIERCE STANTON HUMPHRIES PIERCE ARCHITECTS AEC VAIL, CO AVON, CO 9704788520 Additional Efficiency Package(s) STAN@AEC-VAIL.COM Dedicated Outdoor Air System Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-POOL, ELEC,MECH ROOM(Common Space Types:Electrical/Mechanical) 700 0.95 665 2-POOL HOUSE(Common Space Types:Conference/Meeting/Multipurpose) 400 1.23 492 Total Allowed Watts= 1157 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-POOL, ELEC, MECH ROOM (Common Space Types:Electrical/Mechanical) LED 1: F: LED:Other: 1 9 34 306 2-POOL HOUSE (Common Space Types:Conference/Meeting/Multipurpose) LED 2:C:VANITY:Other: 1 2 25 50 LED 3: D: DOWNLIGHT:Other: 1 3 16 49 LED 4:A: LED PENDENT W/LF:Other: 1 12 10 120 Total Proposed Watts= 525 Interior Lighting PASSES: Design 55% better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.8.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date Project Title: WESTWIND POOL REMODEL Report date: 03/12/18 Data filename: Untitled.cck Page 1 of 7 irdt COMcheck Software Version 4.0.8.0 ii Exterior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: WESTWIND POOL REMODEL Project Type: New Construction Exterior Lighting Zone 2 (Residential mixed use area) Construction Site: Owner/Agent: Designer/Contractor: VAIL, CO BILL PIERCE STANTON HUMPHRIES PIERCE ARCHITECTS AEC VAIL, CO AVON, CO 9704788520 STAN@AEC-VAIL.COM Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) DRIVEWAY AND POOL(Special feature area) 4700 ft2 0.14 Yes 658 Total Tradable Watts(a)= 658 Total Allowed Watts= 658 Total Allowed Supplemental Watts(b)= 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. DRIVEWAY AND POOL(Special feature area 4700 ft2): Tradable Wattage LED 1:AA: EXTERIOR SCONCE:Other: 1 32 15 480 Total Tradable Proposed Watts= 480 Exterior Lighting PASSES: Design 62% better than code Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.0.8.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date Project Title: WESTWIND POOL REMODEL Report date: 03/12/18 Data filename: Untitled.cck Page 2 of 7 COMcheck Software Version 4.0.8.0 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans, specifications, and/or ❑Complies [PR4]1 calculations provide all information ❑Does Not with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. C103.2 Plans, specifications, and/or ❑Complies [PR8]1 calculations provide all information ❑Does Not with which compliance can be determined for the exterior lighting [Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: WESTWIND POOL REMODEL Report date: 03/12/18 Data filename: Untitled.cck Page 3 of 7 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.1 I Lighting controls installed to uniformly ❑Complies [EL15]1 :reduce the lighting load by at least ❑Does Not 50%. [Not Observable ; ENot Applicable C405.2.1 ;Occupancy sensors installed in ❑Complies [EL18]1 'required spaces. ❑Does Not [Not Observable ENot Applicable C405.2.1, ;Independent lighting controls installed I❑Complies C405.2.2. per approved lighting plans and all I❑Does Not 3manual controls readily accessible and [EL23]2 3 ! visible to occupants. ❑Not Observable ENot Applicable C405.2.2. ;Automatic controls to shut off all ;❑Complies 1 :building lighting installed in all ❑Does Not [EL22]2 ;buildings. III Not Observable ; ❑Not Applicable 0 .3 Daylight zones provided with ❑Complies individual controls that control the ❑Does Not lights independent of general area lighting. ❑Not Observable ❑Not Applicable C405.2.3, 'Primary sidelighted areas are ❑Complies C405.2.3. equipped with required lighting ❑Does Not 1, controls. C405.2.3. [Not Observable 2 ❑Not Applicable [EL20]1 1 C405.2.3, Enclosed spaces with daylight area ;❑Complies C405.2.3. under skylights and rooftop monitors ❑Does Not 1, ;are equipped with required lighting C405.2.3. ;controls. ENot Observable 3 ❑Not Applicable [EL21]1 C405.2.4 Separate lighting control devices for ❑Complies [EL4]1 specific uses installed per approved I❑Does Not lighting plans. ENot Observable E Not Applicable C405.2.4 Additional interior lighting power ❑Complies [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is automatically controlled and ❑Not Observable separated from general lighting. ;❑Not Applicable 1 C405.2.5 Automatic lighting controls for exterior ❑Complies [EL25]nu° lighting installed. Controls will be ❑Does Not daylight controlled, set based on business operation time-of-day, or ['Not Observable reduce connected lighting > 30%. ENot Applicable I C405.3 Exit signs do not exceed 5 watts per ❑Complies [EL6]1 face. ❑Does Not E Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 'Medium Impact(Tier 2) 13 I Low Impact(Tier 3) Project Title: WESTWIND POOL REMODEL Report date: 03/12/18 Data filename: Untitled.cck Page 4 of 7 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: WESTWIND POOL REMODEL Report date: 03/12/18 Data filename: Untitled.cck Page 5 of 7 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, :Furnished O&M instructions for ❑Complies C408.2.5. 'systems and equipment to the ❑Does Not 2 building owner or designated [F117]3 representative. [Not Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [F118]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts [Not Observable are less than or equal to allowed ❑Not Applicable watts. C405.5.1 Exterior lighting power is consistent ;❑C mo p ieil s See the Exterior Lighting fixture schedule for values. [F119]1 with what is shown on the approved ❑Does Not lighting plans, demonstrating proposed watts are less than or equal ['Not Observable to allowed watts. ;❑Not Applicable C408. Furnished as-built drawings for EComplies 1 electric power systems within 90 days ❑Does Not [F116]3 of system acceptance. '❑Not Observable ❑Not Applicable C408.3 Lighting systems have been tested to ❑Complies [F133]1 ensure proper calibration, adjustment, ❑Does Not programming, and operation. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 'Medium Impact(Tier 2) 13 I Low Impact(Tier 3) Project Title: WESTWIND POOL REMODEL Report date: 03/12/18 Data filename: Untitled.cck Page 6 of 7 Project Title: WESTWIND POOL REMODEL Report date: 03/12/18 Data filename: Untitled.cck Page 7 of 7