Loading...
HomeMy WebLinkAboutB18-0067_WESTWIND LIGHT FIXTURE CUTS FOR PERMIT_1521238000.PDF Seem° 4 LED FOCAL POINT" RLQ L .,s.-.. recessed wall to ceiling wall mount companion companion companion end detail perimeter companion DIMENSIONAL DATA FEATURES Narrow extruded aluminum 4"linear direct LED. 1 Individual units and continuous runs in 1' increments. 1 Frosted acrylic lens provides uninterrupted illumination, pwithout pixels or shadows. LED position and lens material optimized to provide the o perfect blend of high performance and visual comfort. Choice of output levels to meet a wide variety of application needs. I - Connected Solutions: Integrates with wired and wireless building lighting control systems. 4.00" 101.6mm Preferred Light: Lighting for better color rendition and human preference. PERFORMANCE PRODUCT OVERVIEW Lumen Output: 1500-40001m MOUNTING INFORMATION Wattage: 15-46W _ il LPW: 86-97 T 95.5"----;748"~ SDCM: 3 8'start 4'end 12' T_ 95.5•"I_. 96'_I4 8'start 8'end 11 4'Flush Lens 16' Nominal output: T-95.5•-7---7---5 375 Lumens per foot 8'start 8'intermediate 4'end 20' Delivered Lumens:15001m 95.5' 96 96" T Total System Watts:15W 8'start 8'intermediate 8'end 24' .r,,T1,::per.o:n.pi_..c.,measured in accordance with IESNA LM-79. Consult factory for additional row length information. Visit focalpointlights.com for complete photometric data. Focal Point LLC 1 4141 S.Pulaski Rd,Chicago,IL 60632 1 773.247.94941 focalpointlights.com I Ofocalpointlight November 2017 V fixture: project: DETAILS ORDERING Luminaire Series FSM4LS Seem 4 LED FSM4LS Standard Patterns with 90'Corners Shielding FL Flush Satin Lens FL r°"'" 9`"'I Lumen Output 875 275 Lumens per foot 275LF S - $ (Not available with Lutron Drivers.) e` e` 375 Lumens per foot 375LF , '11 g (Not available with LU5&LH1 Drivers) I " 0� e"^n� I —""` 1— 625 Lumens per foot 625LF ower:o'xaower:6,8' oraer:e'xt'R (3'minimum with LU5&LH1 Drivers) 875 Lumens per foot 875LF 1000 Lumens per foot 1000LF _ "' Color Temperature 30( i ' 3000K 30K 8 orae,. „mge 3500K 35K e` -_ >4 4000K 40K o�—, - 1 ,,a,°,"e"w"efi"°'"-4 3500K Preferred Light P35K Ivera RLe"�°� art r""sawar:ae (Patterns not available.) Ortler:&x6'x4' Ortler:&x6'x4' fir pec five run Ie,gN. Circuit 1C Single Circuit 1C Voltage UNV UNV 120/277 Volt UNV SPECIFICATIONS Control System&Dimming Level LDt LED System 0-10V-10%Dimming LD1 Proprietary linear LED module incorporates premium LEDs on a robust platform to achieve 0-10V-1%Dimming Lii excellent thermal management.LEDs are placed to promote a uniform appearance. Lutron Hi-Lume EcoSystem (LDE1)- Available in 3000K,3500K or 4000K with CRI>80,3SDCM.LED modules and drivers are 1%Dimming LH1 replaceable from below. Lutron 5-Series EcoSystem(LDE5)- 5%Dimming LU5 Construction DALI 1%Dimming D11 One piece extruded aluminum housing.Die cast aluminum end caps.2'unit weight:18 lbs., Acuity nLight-1%Dimming NLT1 3'unit weight:24 lbs.,4'unit weight:30 lbs.,5'unit weight:36 lbs. (3'minimum length.) Optic Enlighted Smart Sensor-1%Dimming ENL1 (3'minimum length.) Reflectors fabricated of 22 Ga.steel finished in High Reflectance White powder coat. Osram Connected Lighting Module- Extruded acrylic lens.085"thick with satin finish,up to 8'continuous. 1%Dimming CLM1 (3'minimum length.Compatible with Daintree Electrical Networks&Osram ENCELIUM and Simplux systems.) Luminaires are pre-wired with factory installed branch circuit wiring and over-molded quick WattstopperDLM-1%Dimming DLM1 connects.Standard 120-277V constant current driver includes 0-10V analog dimming. (3'minimum length.) Dimming range 100%to 10%.Power factor>.9. Mounting C24 Emergency 24"Cable Suspension C24 Output-10 watts for 90 minutes.Maximum mounting height:19.2ft. 48"Cable Suspension C96 See EM/EC Guide for default locations and ordering details. " 96"Cable Suspension C96 (Add P"for Chicago plenum.Eg:CP12) Labels (Specify one of the following in place of"C" J-for 2'canopies at non—feed locations. UL and cUL listed.Suitable for Dry or Damp Locations,indoor use only. CS-for sloped ceiling applications.) Surface Mount SM Finish (Not available with DLM1 or NLT1) Polyester powder coat applied over a multi-stage pre-treatment. Factory Options Lumen Maintenance Emergency Circuit _EC (4'minimumm..7'minimum with Reported: L70 at>61,000 hours Calculated:L70 at 287,000 hours CLM1,DLM1,ENL1&NLT1.) L90 at>61,000 hours L90 at 74,000 hours Emergency Battery Pack _EM (4Derived from EPA TM-21 calculator.Based on typical conditions,consult factory for additional data. E minimum.7'minimum with CLM1,for DLM1, ENL1&NLT1.See EM/EC Guide for default Reliability locations and ordering details.) At Focal Point,our products are designed to stand the test of time.Each luminaire is Finish Titanium Silver TS engineered using superior components,manufactured with the utmost care and rigorously tested.Contact us for reliability data. Matte White Housing WH Luminaire Length As SHOWN Warranty (Leave blank for patterns.Lengths are nominal) LED system rated for operation in ambient environments up to 25°C.5-year limited warranty. Specify luminaire/row X' length in 1'increments (Smaller increments available. 4' PERFORMANCE CHART consult factory for details.) Pattern Options (3'minimum length) Lumens Delivered Tested Specify Shielding Foot Lumens System Watts LWP P Y luminaire/row X' pery length in 1'increments 'L'pattern A'x B' 375LF 1500 15 97 `U'pattern A'x B'x C' 625LF 2500 26 95 Rectangular pattern A'x B'R (Consult factory for other pattern options) Flush Lens 875LF 3500 39 89 1000LF 4000 46 86 Based on 3500k,4'lengths.`Lumen output may vary+1-5%.Actual wattage may vary+1-5%.Preferred Light lumen multiplier=0.65. Focal Point LLC reserves the right to change specifications for product improvement without notification. For more information visit focalpointlights.com/reference or consult factory. CO ECTED Seem® 4 SOLUTIONS LED Focal Point provides flexibility in meeting the needs of each project by integrating with several building lighting control systems.A variety of sensors, drivers and other components can be specified that allow the luminaires to communicate with wired and wireless networks.All zoning can be digitally reconfigured through the application software.Daylight harvesting,occupancy sensing,integration with HVAC systems,and individual controls enable the monitoring and modulating of light levels and temperature in order to save energy,reduce costs and maximize occupants'comfort. aTrt. a ' 4? ae. • .... nLight®provides a two-way wired digital Enlighted smart sensor allows for occupancy o lighting system allowing for on/off and sensing,daylight harvesting,energy usage, dimming functionality,occupancy sensing, temperature and light level control.Communicates and multi-zone daylight harvesting. wirelessly with the Enlighted network. Connections located under Enlighted Smart Sensor-1%Dimming(ENL1) access panel. Acuity nLight-1%Dimming(NLT1) Acuity Model#nEPS 60 lO Enlighted Model#SU-4E-01 _� I i I CAT-5 Cableprovided between segments of a run. Runs 9 CAT-5 Cable provided by others at start of run.Serial labels will be provided on outside of luminaires and control unit. OSRAM L'llegrand° WATTSTOPPER® Connected Lighting Module(CLM)enables each luminaire to be independently controlled and A Digital Lighting Management(DLM)system that configured.Communicates wirelessly with Daintree o provides two-way wired communication between 111, Networks®,Osram ENCELIUM®,Osram Simplux'M410' networked luminaires and control system to allow and other networks using the ZigBee®HA J for on/off and dimming functionality,occupancy - # communication protocol to allow for on/off and connections sensing and multi-zone daylight harvesting. dimming functionality,occupancy sensing and located under multi-zone daylight harvesting. access panel. Wattstopper DLM-1%Dimming(DLM1) Wattstopper Model#LMFC-011 Osram CLM-1%Dimming(CLM1) I--- —mRuns ' Segment Network Wire provided between segments of a Osram Model#ZBHA-CLM DIM run.Segment Network Wire provided by others at start of run.Serial labels will be provided on outside of luminaires Serial labels will be provided on outside of luminaires and control unit. and control unit. OLUTRON® N. A two-way digital network that enables on/off and dimming functionality,occupancy sensing,and multi-zone daylight harvesting working with Quantum®,Energi Savr Node'',and Energi TriPak® using Ecosystem®communication protocol. Lutron Hi-Lume Ecosystem-1%Dimming(LH1) Lutron Model#LDE1 Lutron 5-Series EcoSystem-5%Dimming(LU5) Lutron Model#LDE5 CONNECTED SOLUTIONS DETAILS Connected Model# Protocol Compatible Occupancy Daylight Temperature Communication Drivers Solution Networks* Reporting to Luminaire Acuity nLightnEPS-60-IO** nLight nLight Enabled Enabled No Wired eldoLED ECOdrive, (NLT1) eldoLED SOLOdrive Enlighted SmartSU-4E-01** Enlighted RF Enlighted Integrated Integrated Yes Wireless Philips SimpleSet, Sensor(ENL1) Osram Optotronic Legrand Philips SimpleSet, Wattstopper DLM LMFC-011** DLM DLM Enabled Enabled No Wired Osram Optotronic (DLM1) Lutron EcoSystemQuantum,Energi Savr Lutron Hi-Lume (LH1 &LU5) LDE1;*LDE5** EcoSystem Node,Energi TriPak Enabled Enabled No Wired Lutron 5-Series Osram CLM Osram ENCELIUM (CLM1) ZBHA-CLM** ZigBee HA &Simplux,Daintree Enabled Enabled No Wireless Osram Optotronic Networks *Not all compatible networks may be listed.""For performance data and additional control system details please visit the connected solutions manufacturer websites.Primary drivers are listed in bold.To specify a particular driver please consult factory. Seem° 1 FSM4L-FL-1000LF-35K-1C-UNV-LD1-G1-CP-WH-4r Lumens: 14231m Filename: FSM4LFL375LF35K.IES System Watts: 15W LED-FLUSH LENS Test#: 11499493.01 LPW: 95 CANDLEPOWER DISTRIBUTION LUMEN SUMMARY Vertical Horizontal Angle 180°170° 160° 150° 140° Angle 0° 22.5' 45° 67.5' 90° Zone Lumens Fixture 496 .. 130° 0° 496 496 496 496 496 0-30° 384 27.0 397 . 5° 493 496 493 493 494 0-40° 627 44.1 298 riff* 120° 15° 475 479 475 476 477 0-60° 1103 77.5 198 ,�,. 110° 25° 439 443 439 440 440 Total 0-90° 1423 100.00 99 Er_go100° 45° 322 326 322 323 324 Luminaire 0_180° 1423 100.0 . 35° 386 39 387 387 388 0 I---.---08,1 -■ 55° 253 255 253 254 254 0° 65° 176 179 178 179 180 99 198 11 ,,',� 70° 75° 100 102 102 104 104 296 ;:','.. 60° 90° 01 32 31 31 21 LUMINANCE DATA(CDIM5) 397 ..,.. 50° 95° 0 0 0 0 0 Vertical Horizontal 0° Angle 45 90' 496 105 0 0 0 0 0 0° 10' 20° 30° 40° 45° 3757 3760 3774 115° 0 0 0 0 0 55° 3634 3642 3657 0`---- 0°45° 125° 0 0 0 0 0 45° 90° 65° 3441 3473 3506 90° 135° 0 0 0 0 0 75° 3193 3261 3313 145 0 0 0 0 0 85° 2923 2967 2970 155 0 0 0 0 0 165° 0 0 0 0 0 175° 0 0 0 0 0 180° 0 0 0 0 0 Go to www.focalpointlights.com for additional photometric data. note:Photometric testing performed in an independent lab with standard lamps and ballasts.Lamp and ballast type and configuration will affect photometric performance. QLS420 LED 620-3528 We-ef 1/2 Description Beam Type asymmetric,side throw beam[S] IP66,Class I.IKO7.Surface mounted LED wall luminaire.Marine-grade,die Lamp Type LED 6/12W/700 mA 4000 K cast aluminum alloy.5CE superior corrosion protection including PCS hardware.Silicone rubber gasket.Safety glass lens.Integral EC electronic CRI 80 converter.CAD-optimised optics for superior illumination and glare control. Gear Type electronic gear OLC®One LED Concept.Factory installed LED circuit board.0-1Oy on request. Suitable for installation over 4"recessed junction box. Nominal Luminous Flux(Im) LED Lumens 246 Im LEDs 6 Total Lumens 1476 Im Tj 85°C Rated Luminous Flux(Im) LED Lumens 156.6 Im Total Lumens 939.6 Im Ta 25°C Rated Input Power 15 W WE-EF LIGHTING USA LLC 410-D Keystone Drive I Warrendale PA 150861 U.S.A.I Tel+1 72474200301 Fax+1 72474200351 info.usa@we-ef.com 1 www.we-ef.com QLS420 LED 620-3528 We-ef 2/2 WAIFif lif 1.0102 8.27" 111111111147 • • 74111 MIL 00441044/rir 9 0.24" o 00 4/twrio.# ❑9.06" CO 13501 _ C90 0270—f— 1269 cd/klm l 1800- —10.7°/10.7° J LJ 0180 28.9°/28.9° 9.06' 3.74" 4.72" C0/C180 C90/C270 Material Specification Body: Luminaire body and lens frame constructed in die cast aluminum. Weight(lbs): 15.00 Lens: Clear tempered glass lens. Gasket: Silicone rubber gasket Fasteners: PCS polymer coated stainless steel Ingress protection: IP66 Impact protection: IK07 Corrosion protection: 5CE Finish: Powder coat finish in Black RAL9004,White RAL9016,Grey Metallic RAL9007 or Dark Bronze RAL8019. Mounting: Suitable for installation over a standard 4"recessed junction box. Electrical Specification Power supply: Integral[ECG]LED driver in 120-277V Ballast: Integral EC electronic converter Cable: Two cable entries Ambient Temperature Ta less than 25 deg C WE-EF LIGHTING USA LLC 410-D Keystone Drive I Warrendale PA 150861 U.S.A.I Tel+1 7247420030I Fax+1 7247420035I info.usa@we-ef.com I www.we-ef.com SLAT - model:WS-806 211 LED Vanity MODERN FORMS A WAC LIGHTING COMPANY Fixture Type: —— Catalog Number: Project: %8' 3" Location: X18"_ WS-80618 %8" %8" 3 3 24" 36" WS-80624 WS-80636 PRODUCT DESCRIPTION SPECIFICATIONS A sliver of light illuminates a dressing room,bath or corridor with a soft, Construction:Aluminum. flattering glow.This slim and shallow design with crisp edges and a Light Source:High output LED. brushed aluminum frame simply modernizes any decor. Finish:Brushed Aluminum(AL). Standards:ETL&cETL damp location listed.ADA compliant.CEC Title 24. FEATURES • Advanced Edge Lit Technology • Mount vertically,horizontally,or on ceiling • ADA compliant,low profile design • ETL&cETL damp location listed • CEC Title 24 Compliant • Listed for use in closets • Full range dimming when used with compatible dimmers • Transformer located in outlet box • Conversion plate for 4"J box included • 277V option available special order • 85,000 hour rated life • Color Temp:3000K • CRI:90 ORDER NUMBER LED Delivered Model Length Wattage Voltage Lumens Lumens Finish WS-80618 18" 13W 1129 378 WS-80624 24" 19W 120V 1504 537 AL Brushed Aluminum WS-80636 36" 25W 1860 780 Example:WS-80618-AL For 277V special order,add an"F"before the finish:WS-80624F-AL modernforms.com Headquarters/Eastern Distribution Center Central Distribution Center Western Distribution Center Phone(800)526.2588 44 Harbor Park Drive 1600 Distribution Ct 1750 Archibald Avenue Fax (800)526.2585 Port Washington,NY 11050 Lithia Springs,GA 30122 Ontario,CA 91760 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. G 1.7.59 JUf10 4" IC AND TC 1000 LUMEN Project: INTERNALLY ADJUSTABLE Fixturelype: FIXTURE TYPE D LED DOWNLIGHT Location: NEW CONSTRUCTION Contact/Phone: IC4AL, TC4AL ( 1 OLM) RECESSED HOUSING 11' LENSED TRIMS PRODUCT DESCRIPTION Patent pending dedicated LED,Air-Loc®sealed new construction housing with integral internally adjustable light engine•Double wall, shallow housing construction•IC4AL series can be completely covered iii: with insulation and installs in 2 x 6 construction•TC4AL series for Nit use in non-insulated areas(If installed where insulation is present,the insulation must be pulled back 3"from all sides of the TC housing) •Fully sealed housing stops infiltration and exfiltration of air,reducing heating and cooling costs without the use of additional gaskets •LED housing is designed to provide 50,000 hours of lite•5 year limited warranty on LED components. DIMENSIONS ENVIRONMENTALLY FRIENDLY,ENERGY EFFICIENT 'i I '' • No harmful ultraviolet or infrared wavelengths • No lead or mercury,RoHS compliant •Comparable light output to 75W incandescent PRODUCT SPECIFICATIONS 0II 0 '� LED Light Engine LED array attached to cast aluminum sliding heatsink W� 6 3/4" integrated directly with housing provides superior heat transfer to 6„ ensure long life of the LED•Replaceable light engine mounts directly to inner housing assembly and incorporates the latest generation,high lumen output LED arra •LEDs are binned within a 3-step MacAdam - il _ . II Ellipse exceeding ENERGY STAR®requirements for superior fixture to fixture color uniformity•2700K,3000K,3500K,or 4000K color temperatures available•90 CRI minimum. 81/2 Optics Three field interchangeable,TIR optics available in 18°,30° and 40°beam angles•Module can accommodate one 2-inch 11 7/8" diameter beam control lens or filter•Adjustable light engine module provides up to 35°vertical adjustment and 360°rotation. Aesthetic Trim Selections Adjustable perimeter frosted lensed trim •Shadow free,knife edge design blends seamlessly into ceiling •Trims are wet location approved for covered ceiling applications. LED Driver Choice of dedicated 120 volt(120)driver or universal 0 6" voltage(MVOLT)driver that accommodates input voltages from ;' 120-277 volts AC at 50/60Hz•Power factor>0.9 at 120V input •120 volt only driver is dimmable with the use of most incandescent, magnetic low voltage and electronic low voltage wall box dimmers 4 1/2" CEILING CUTOUT •Universal voltage driver is dimmable with the use of most 0-10V wall box dimmers•For a list of compatible dimmers,see JUNOICLED-DIM. Life Rated for 50,000 hours at 70%lumen maintenance. ELECTRICAL DATA Labels UL listed for U.S.and Canada for through-branch wiring, Dedicated 120V Only Driver Option (120) wet locations(covered ceilings) •Union made•UL and cUL. 120V Testing All reports are based on published industry procedures;field Input Power 16.4W(+/-5%) performance may differ from laboratory performance. Input Current 0.15A Specifications subject to change without notice. Frequency 50/60Hz HOUSING FEATURES EMI/RFI FCC 47(FR,Part 15, Class ass ( B(Residential) Housing IC4AL designed for use in IC(insulated ceiling)or non- Minimum starting temp -25°C(-13°F) IC construction•TC4AL designed for use in non-IC construction •Aluminum housing sealed for Air-Loc®compliance•Housing is Universal Voltage Driver(MVOLT IT) vertically adjustable to accommodate up to a 1'/s"ceiling thickness. 120V 277V Junction Box Pre-wired junction box provided with(6) '/z"and Input Power 16.0W(+/-5%) 16.0W(+/-5%) (1)3/4"knockouts,(4)knockouts for 12/2 or 14/2 NM cable and Input Current 0.15A 0.06A ground wire•UL listed and cUL listed for through-branch wiring, Frequency 50/60Hz 50/60Hz maximum 4#12 branch circuit conductors•Junction box provided EMI/RFI FCC Title 47 CFR,Part 15, FCC Title 47 CFR,Part 15, with removable access plates•Knockouts equipped with pryout slots Class A(Commercial) Class A(Commercial) •Quick connect electrical connectors supplied as standard for fast, Minimum starting temp 20°C(4°F) 20°C(4°F) secure installation. Mounting Frame 22-gauge die-formed galvanized steel mounting Lutron Hi-Lume®LED Driver(MVOLT ECOS3) frame•Rough-in section(junction box,mounting frame,housing 120V 277V and bar hangers)fully assembled for ease of installation. Input Power 16.4W(+1-5%) 16.6W(+/-5%) Real Nail 3 Bar Hangers Patented(US Patent D552,969) Input Current 0.15A 0.07A Real Nail°3 bar hangers:telescoping system permits quick placement Frequency 50/60Hz 50/60Hz of housing anywhere within 24"O.C.joists or suspended ceilings EMI/RFI FCC Title 47 CFR,Part 15, FCC Title 47 CFR,Part 15, •Includes removable nail for repositioning of fixture in wood joist Class A(Commercial) Class A(Commercial) construction•Integral T-bar notch and clip for suspended ceilings. Minimum starting temp 0°C(32°F) 0°C(32°F) cuityBrands, 1300 S.Wolf Road•Des Plaines,IL 60018•Phone(8471 827-9880•Fax 18471 827-2925•Visit us at www.acuitybrands.com/Juno-recessed Printed in U.S A. ©2017 Acuity Brands Lighting,Inc. Rev.03/01/17 1 of 3 G 1.7.59 4" IC AND TC 1000 LUMEN INTERNALLY ADJUSTABLE LED DOWNLIGHT NEW CONSTRUCTION IC4AL, TC4AL ( 1 OLM) RECESSED HOUSING LENSED TRIMS ORDERING INFORMATION Housing and trim can be ordered together or separate,but will always ship separately. Example:IC4AL 10EM 27K 90CRI FL 120 FRPC — — Lumens Color Temperature CRI Distribution Voltage Driver IC4AL 4"LED Internally Adjustable 10LM 1000 Nominal Lumens 27K 2100K 90CRI 90+CRI FL Flood 120 120V FRPC Forward/Reverse Phase Cut New Const.IC Downlight 30K 3000K NFL Narrow Flood MVOLT Multi-Volt IT 0-10V Dimming Driver 35K 3500K SP Spot (120.277VI 40K 4000K Notes:120 must be ordered with FRPC.MVOLT must be ordered with 11 Example:TC4AL 10LM 27K 90CRI FL MVOLT ECOS3 Lumens Color Temperature CRI Distribution Voltage J Driver TC4AL 4"LED Internally Adjustable 10LM 1000 Nominal Lumens 27K 2700K 90CRI 90+CRI FL Flood MVOLT Multi-Volt ECOS3 Lumen Hi-Lume A Series,3-wire fluorescent New Const.Non IC Downlight 30K 3000K NFL Narrow Flood controls R.Lotion Ecosystem 35K 3500K SP Spot 40K 4000K Trim/Description Accessories(ordered separately) 41 L ABZ 4"Adjustable Lens Shower Trim-Classic Aged Bronze Catalog Number Description ( A(` 41 L SC 4"Adjustable Lens Shower Trim-Satin Chrome CGF 200 MPINK Color Glass Filter-2"Diameter-Medium Pink 4:/10-1 41L WH 4"Adjustable Lens Shower Trim-White CGF 200 WRED Color Glass Filter-2"Diameter-Warm Red OF 200 DLTBLUE Color Glass Filter-2"Diameter-Daylight Blue CGF 200 MBLU Color Glass Filter-2"Diameter-Medium Blue CGF 200 MAMB Color Glass Filter-2"Diameter-Medium Amber Trim Size:5"O.D. CGF 200 MGRN Color Glass Filter-2"Diameter-Medium Green Note:In Canada when insulation is present,Type IC fixtures must be used. DGF 200 DRED Dichroic Glass Filter-2"Diameter Red DGF 200 MGRN Dichroic Glass Filter-2"Diameter Medium Green DGF 200 MBLU Dichroic Glass Filter-2"Diameter Medium Blue DGF 200 DYEL Dichroic Glass Filter-2"Diameter Yellow(Dichroic) DGF 200 MAGEN Dichroic Glass Filter-2"Diameter Magenta DGF 200 CYAN Dichroic Glass Filter-2"Diameter Cyan DCCF 200 HL4250 Dichroic Color Correction Filter 2'Diameter-Halogen to-Daylight DIFF 200 Diffusion Glass Lens 2"Diameter UVF 200 UV Filter Lens-2"Diameter HCLBL 200 Hexagonal Cell Louver-Black-2"Diameter LSPREAD 200 Linear Spread Glass Lens-2"Diameter PRISM 200 Prismatic Glass Lens 2"Diameter TIR2 SPT TIR Optic-Spot TIR2 NFLD TIR Optic-Narrow Flood TIR2 FLD TIR Optic-Flood 4cuityBrands, 1300 S.Wolf Road•Des Plaines,IL 60018•Phone(847)827-9880•Fax(847)827-2925•Visit us at www.acuitybrands.com/Juno-recessed Printed in U.S.A. ©20 17 Acuity Brands Lighting,Inc. Rev.03/01/17 2 of 3 G 1.7.59 4" IC AND TC 1000 LUMEN INTERNALLY ADJUSTABLE LED DOWNLIGHT NEW CONSTRUCTION IC4AL, TC4AL ( 1 OLM) RECESSED HOUSING PHOTOMETRICS LENSED TRIMS PHOTOMETRIC REPORT Candlepower PHOTOMETRIC REPORT Candlepower PHOTOMETRIC REPORT Candlepower Test Report:PT09153003R Distribution Test Report:PT09152923R Distribution Test Report:P1090152903R Distribution (Candelas) (Candelas) (Candelas) Catalog No:IC4AL 1OLM 35K 90CRI Degrees Catalog No:IC4AL 10LM 35K 90CRI Degrees Catalog No:IC4AL 101M 35K 90CRI Degrees SP 120 FRPC with 41L WH and Vertical Candela NFL 120 FRPC with 41L WH and Vertical Candela FL 120 FRPC with 41L WH and Vertical Candela Spot Optic 0° 142 Narrow Flood Optic 0° 135 Flood Optic 0° 139 Watts:16.4 5° 191 Watts:16.4 5° 183 Watts:16.4 5° 254 Lumens:848 10° 271 Lumens:867 10° 233 Lumens:936 10° 487 Luminaire LPW:52 15° 452 Luminaire LPW:53 15° 468 Luminaire LPW:57 15° 826 90 20° 828 20° 1208 eo 200 1280 700 ....., es 250 1735 �o 73-40Vyagl e5 25° 2208 �0'��1g05 25° 1782 L\,,�'•wair i 30° 3387 \\ �1��11, 30° 2836 0,��1��1,, 30° 2142 1400 111". -�r♦. 75 35° 4633 eon D\ ���. '6 35° 3030 600 � �����. 'S 35° 2305 \�•����� , ss 40° 3756 44 .�.., D�OO� 65 40° 2782 �� � es 40° 2226 210°�0���\•9 45° 2039 1800 ��.•.,, 45° 2169 900 s\����� , 45° 1716 2800 11�6S ss 50° 903 sow O� �, 55 50° 1288 1x00 11114n �\• Ss 50° 1107 ������,, 55° 318 �� , •���, 55° 408 �����% 55° 619 3600 III-W*�.,�� 60° 150 r ��i� 60° 149 1500 =��� 60° 405 4200 No as 65° 84 2800 = * .4 45 65° 93 1w0 NO N. �•45 65° 224 ��' 70° 54 _�� 70° 53 ���' 70° 95 4900 = 75° 32 3200 = 75° 27 2100 lig 750 28 5600 35 80° 15 3600 1111100 110 35 80° 12 2400 _' 35 80° 10 85° 4 _' 85° 3 =', 85° 1 INAILLIIi 0 s 15 25 90° 0 0 5 15 25 90° 0 0 5 1 25 90° 0 CBCP°Centerbeam candlepower FOR HORIZONTAL AIMING ANGLES FOR VERTICAL AIMING ANGLES FC°Footcandles at beam center(aim point) / 0 MEM k x In vertical aiming applications,aim point WLR ° •WS" °A t" (X)is determined by dividing distance from the wall ID)by the tangent of the desired / i. \ �� aim angle(A)(0.5774 for 30°,1.0 for 451. "'"'n9 Angle(AA) /Wing Angle(A=y) Horizontal Aiming Angles Vertical Aiming Angles Beam Beam 0° 30° 300 FIXTURE Type Seread° _CBCP MH FC I W FC I W D FC X L W IC4AL(10LM) SP 18° 4633 4 290 1.3 1.3 188 1.7 1.5 2 145 3.5 2.7 1.3 LED,3500K 6 129 1.9 1.9 84 2.6 2.2 3 64 5.2 4.1 1.9 Spot i8 72 2.5 2.5 47 3.4 2.9 4 36 6.9 5.5 2.5 10 46 3.2 3.2 30 4.3 3.7 5 23 8.7 6.9 3.2 12 32 3.8 3.8 21 5.1 4.4 6 16 10.4 8.2 3.8 IC4AL(10LM)NFL 30 3030 4 189 2.1 2.1 123 2.9 2.5 2 95 3.5 5.5 2.1 LED,3500K 6 84 3.2 3.2 55 4.4 3.7 3 42 5.2 8.2 3.2 Narrow / 8 47 4.3 4.3 31 5.9 5.0 4 24 6.9 10.9 4.3 Flood1 0 30 5.4 5.4 20 7.3 6.2 5 15 8.7 13.7 5.4 12 21 6.4 6.4 14 8.8 7.4 6 11 10.4 16.4 6.4 IC4AL(10LM) F. 40 2305 4 144 2.9 2.9 94 4.1 3.4 2 72 3.5 9.7 2.9 LED,3500K 6 64 4.4 4.4 42 6.1 5.0 3 32 5.2 14.5 4.4 Flood A8 36 5.8 5.8 23 8.1 6.7 4 18 6.9 19.3 5.8 10 23 7.3 7.3 15 10.2 8.4 5 12 8.7 24.2 7.3 12 16 8.7 8.7 10 12.2 10.1 6 8 10.4 29.0 8.7 Multipliers:27K-0.93 30K-0.96 35K-1.00 40K-1.03 cuityBrands, 1300 S.Wolf Road•Des Plaines,IL 60018•Phone(8471 827-9880•Fax(847)827-2925•Visit us at www.acuitybrands.com/Juno-recessed Printed in U.S.A. ©2017 Acuity Brands Lighting,Inc. Rev.03/01/17 3 of 3 ID4 . 5 " _______________ __________ LED DOWNLIGHT FOCAL POINT" IIII clear diffuse warm diffuse white painted flange } ( ' Er .....2.. I black reflector white reflector trimless companion DIMENSIONAL DATA FEATURES ChromaSure: Color consistency resulting in a 2-step MacAdam ellipse across the entire ID+ product line. Downlight 12.59" Field adjustability of ceiling thickness from 0.5"-2.5" 319.8mm P_ ' Shallow housing�O ll 50°cutoff to light source and its image. _„,11 rri �r N Selection of dimming drivers available. V Right Light:Standard delivered lumen outputs 1000, 1500, �� 2000, 2500,and 3000. 0.5zi' II- 4.50" 114.3mm 5.50" 139.7mm PERFORMANCE Trim v 111 A PRODUCT OVERVIEW Lumen Output: 1000-30001m A 1��I .o Wattage: 12-45W ' _ LPW: 66-81 Spacing Criteria: 1.01-1.02 11.02" 5.50" SDCM: 2 279.9mm 139.7mm Clear Diffuse Reflector 3500k ^ Delivered Lumens:20001m Total System Watts:26W H,iolorue.r re perlorerarree Ic measured in accordance with IESNA LM-79. Visit focalpointlights.com for complete photometric data.Visit energystar.gov for model specifics. Focal Point LLC 14141 S.Pulaski Rd,Chicago,IL 60632 1773.247.9494 I focalpointlights.com I @focalpointlight August 2017 R fixture: project: HOUSING ORDERING HOUSING DETAILS + Housing Series FLC4D ID 4.5"Round Downlight FLC4D Trim Type RO Standard Emergency Battery Chicago Plenum Round Overlap RO (Click to view trimless cutsheet) Lumen Output 875 t=0 _ 1000 Lumens 1000E A11:1 1500 Lumens 1500L 111 0 o 2000 Lumens 2000L 2500 Lumens 2500L O-'( • �y�,' off, 3000 Lumens 3000E Voltage 120 LxWxH LxWxH Standard LxWxH 120V 120 12.59"x 11.02"x 5.20" 16.21"x 11.21"x 6.02" 16.85"x 11.45"x 6.13" 277V** 277 Emergency L x W x H Control System&Dimming Level LD1 16.85"x 12.95"x 6.13" 0-10V-1%Dimming L11 0-10V-10%Dimming LD1 Lutron Hi-Lu me EcoSystem(LDE1)- 1%Dimming LH1 HOUSING SPECIFICATIONS Lutron 5-Series EcoSystem(LDE5)- Construction 5%Dimming LU5 (Not available with 1000L&3000L) Thermally protected housing for new construction applications.Insulation to be kept 3" DALI-1%Dimming D11 away from housing.Butterfly brackets allow mounting to 1/2 emt.Order bar hangers as DMX-3-Channel,0%Dimming MZ3 an accessory.Die-cast aluminum heat sink designed for maximum thermal dissipation. Die-formed housing and integral junction box with(7) 1/2"pry outs. UL&cUL Housing Type T listed for(6)#14 AWG(3 in,3 out)90°C conductors and feed through–branch wiring. Thermally Protected,Non-IC T Accommodates ceiling thicknesses up to 0.5"standard,field adjustable up to 2.5" Factory Options thickness.For thicker ceiling consult factory.Order TZB option for TechZone compatible Bar Hangers BH housing brackets.Fixture will not exceed 5 lb. Chicago Plenum/National Plenum CP Electrical Emergency Battery EM (Must order LC4EM trim) Choice of constant current dimming drivers.Power factor>.9 typical. 6"TechZone Brackets TZB Emergency TRIM &LED MODULE Emergency Battery Pack:Bodine BSL17C–C2.Emergency output—7W for 90 minutes. LC4 Aperture Maximum mounting height:23.3ft.(Black reflector color:18.1ft.) 4.5"Round Reflector LC4 Labels 4.5"Round Reflector-Emergency LC4EM UL and cUL listed.Suitable for Dry or Damp Locations,indoor use only.Specify wet listed (Required for"EM"option) (WL)for recessed ceiling applications in indoor and outdoor locations.Lutron Drivers not Trim Type RD recommended for outdoor environments below 0°C. Round RD Lumen Output 1500 Lumen Maintenance (Trim&Housing output must match) Reported:L70 at>63,000 hours 1000 Lumens 1000L Derived from EPA TM-21 calculator.Based on typical conditions,consult factory for additional data. 1500 Lumens 1500L Reliability2000 Lumens 2000L 2500 Lumens 2500L At Focal Point,our products are designed to stand the test of time.Each luminaire is 3000 Lumens 3000L engineered using superior components,manufactured with the utmost care and rigorously 30K tested.Contact us for reliability data. Color Temperature 2700K 27K Warranty 2700K,90CRI 927K LED System rated for operation in ambient environments up to 25°C.5-year limited warranty. 3000K 30K TRIM&LED SPECIFICATIONS 3000K,90CRl 930K 3500K 35K LED System 3500K,90CRI 935K Proprietary array incorporates premium LEDs on a robust platform.May be specified in 4000K 40K 2700K,3000K,3500K or 4000K,CRI>80.Color accuracy within 2 SDCM.Aluminum heat sink 4000K,90CRI 940K provides appropriate thermal management. Optic DN Aesthetics Downlight DN Parabolic reflector cone ensures glare free optics.Reflector is.050 spun aluminum. Color CD Torsion springs pull trim tight to the ceiling with no visible fasteners within the trim.Trims Clear Diffuse CD are self-flanged.Non-painted trim matches reflector finish.White painted flange may also Warm Diffuse WD be specified. Black BK Optics (Black Painted flange WH 50-degree cut–off to light source and its image. (White Painted flange only) Flange Finish WP PERFORMANCE CHART Non-Painted NP (Clear and warm diffuse only) Delivered Lumens System Watts LPW Black Painted BP WI Tinted WP 1000 12 81 Factory Options 15000* 19 78 Wet Listed WL WL (Not available with 90CRI) 2000** 26 76 A complete unit consists of two line items,housing and trim 2500 36 70 Example:FLC4D-RO-1500L-120-LD1-T I LC4-RD-1500L-35K-DN-CD-NP 3000 45 66 Options:n orange qualify for the Qraoksh:p program.5-day up to Based on 3000/3500K.Clear Diffuse reflector cone.80CRI Multipliers:2700K:0.94,4000K:0.1.06.90CRI Multipliers:2700K: Qa7 5 DAY* 100 pieces.Refer to Qulckship Guide for complete details. 0.71,3000/3500K:0.83,4000K:0.89.Black Multiplier:0.56.White Multiplier:1.13.Lumen output may vary+/-5%.Actual wattage may vary+1-5%.**LU5 output:1500L=12501m,2000L=18001m. Focal Point LLC reserves the right to change specifications for product improvement without notification. For more information visit focalpointlights.com/reference or consult factory. ± 4 . I D II FLC4D-R0-1000L-120-L11-T/LC4-R0-1000L-35K/40K-DN-CD-NP 5 Filename: FLC4DR01000L 35K 40K DNCD.IES Lumens: 10821m LED DOWNLIGHT Test it: 1100914 System Watts: 13W LPW: 83 CANDLEPOWER DISTRIBUTION LUMEN SUMMARY Vertical Horizontal Angle % r' N w m o Ki `i:'1) v � A Angle p° Zone Lumens Fixture 90°N I ~90 0° 1082 0-30° 768 71.0 1111111101101W 744111111411111111111 80° .-''l ` .. 80° 5° 1080 0-40° 1014 93.7 70° ..,,,�-v/111�v* *. 70° 15° 1046 0-60° 1081 99.9 60° ..,,��,,',��',.. 60° 25° 826 0-90° 1082 100.0 Total .4111111111111.1•4 .,,. . 35° 398 Luminaire 0-180° 1082 100.0 45° 69 50° �..� 50° 55° 6 40° 30° 20° 10° 0° 10° 20° 30° 40° 65° 0 0°---- 90°45° 75° o4m. FOOTCANDLE VALUES 95° p° 85° 0 90° 0°aiming angle-horizontal surface 90° 0 - a Distance Beam Center from source Diameter Beam(FC) s 1 4' 5.0' 68 6' 7.5' 30 s rc 8' 10.0' 17 10' 12.5' 11 Footcandle results based on AGI32;Reflectances=0/0/0;LLF=1 Go to www.focalpointlights.com for additional photometric data. ID � 'I FLC4D-R0-1500L-120-L11-T/LC4-R0-1500L-35K/40K-DN-CD-NP 1 ��VFilename: FLC4DR01500L 35K 40K DNCD.IES Lumens: 16761m LED DOWNLIGHT Test#: 1100916 System Watts: 21W LPW: 80 CANDLEPOWER DISTRIBUTION LUMEN SUMMARY N Vertical Horizontal Angle o m .. Angle p° Zone Lumens Fixture _�I ��- 0° 1645 0-30° 1178 70.3 90° .-��II1```�� 90° 80° 80° 5° 1645 0-40° 1559 93.0 70° ••,,��/1I1,Z�,''• 70° 15° 1599 0-60° 1671 99.7 60° . . 60° 25 1272 0-90° 1676 100.0 50° ••,� �'•• 50° 45° 616 Total .,,. Luminaire 0-180° 1676 100.0 �1ii� 55° 14 40° 30° 20° 10° 0° 10° 20° 30° 40° 65° 4 90° FOOTCANDLE VALUES 0°---- 5° 75° 0 7—_ 45° o 90° 85 0 m 0°aiming angle-horizontal surface 90° 0 's Distance Beam Center i from source Diameter Beam(FC) 4' 5.0' 103 6' 7.5' 46 s rc 8' 10.0' 26 10' 12.5' 16 Footcandle results based on AGI32;Reflectances=0/0/0;LLF=1 Go to www.focalpointlights.com for additional photometric data. ± 4 I D I I FLC4D-R0-2000L-120-L11-T/LC4-RO-2000L-35K/40K-DN-CD-NP ��VJJ Filename: FLC4DR02000L 35K 40K DNCD.IES Lumens: 20501m LED DOWNLIGHT Test#: 1117165 System Watts: 27W LPW: 76 CANDLEPOWER DISTRIBUTION LUMEN SUMMARY M ti Vertical Horizontal Angle v „ ,a Angle 0° Zone Lumens Fixture _�� ��_ 0° 2016 0-30° 1436 70.1 80° ■ I �II`�>``�■ 60° -nig. ,/111 ,'. 5° 20131938 0-60° 1907 93.0 042 99.6 60° •,,� �,'•41.,, 4 60" 25° 1555 Total 0-90° 2050 100.0 ,1 35° 760 Luminaire 0-180° 2050 100.0 50° W1..1P 50° 45° 136 55° 16 40° 30° 20° 10° 0° 1V 20° 30° 40° 65° 5 °°---- 5` 75° 2 FOOTCANDLE VALUES 45° 7-- 90° 85° 90° 0 - 0°aiming angle-horizontal surface I Distance Beam Center from source Diameter Beam(FC) s s 4' 5.0' 126 6' 7.5' 56 s rc 8' 10.0' 31 10' 12.5' 20 Footcandle results based on AGI32;Reflectances=0/0/0;LLF=1 Go to www.focalpointlights.com for additional photometric data. ID � 'I FLC4D-RO-2500L-120-L11-T/LC4-RO-2500L-35K/40K-DN-CD-NP 1 ��VFilename: FLC4DR02500L 35K 40K DNCD.IES Lumens: 25021m LED DOWNLIGHT Test#: 1117163 System Watts: 36W LPW: 70 CANDLEPOWER DISTRIBUTION LUMEN SUMMARY Vertical Horizontal Angle v m ,�, „ N Angle 0° Zone Lumens Fixture o90° 111111111111514..‘7,74.41411111111111. . 0° 2460 0-30° 1753 70.1 60° . . 80 5° 2457 0-40° 2326 93.0 60° •,,��J,,',p���,'• 60° 15° 2365 0-60° 2492 99.6 *It Ili v4 35° 9277 0-90° 2502 100.0 Total Luminaire 0-180° 2502 100.0 50° .1��1� 50° 45° 166 55° 20 40° 30° 20° 10° 0° 10° 20° 30° 40° 65° 6 7 41011. FOOTCANDLE VALUES 0°———— { 45° 75° 2 T 45° 0 90° 85° 1 _ 0°aiming angle-horizontal surface 90° 0 a Distance Beam Center i from source Diameter Beam(FC) 4' 5.0' 154 6' 7.5' 68 s rc 8' 10.0' 38 10' 12.5' 25 Footcandle results based on AGI32;Reflectances=0/0/0;LLF=1 Go to wwn.focalpointlights.com for additional photometric data. ± 4 . I D II FLC4D-RO-3000L-120-L11-T/LC4-RO-3000L-35K/40K-DN-CD-NP 5 Filename: FLC4RD03000L 35K 40K DNCD.IES Lumens: 2953!m LED DOWNLIGHT Test#: 1117164 System Watts: 45W LPW: 66 CANDLEPOWER DISTRIBUTION LUMEN SUMMARY T- M 8 Vertical Horizontal Angle % „ „ „ N Angle 0° Zone Lumens Fixture 9M 90° _W%741_0111111 0° 2904 0-30° 2070 70.1 .001. /111ep „iiir5°7C r 29002792 0-60° 2746 93.0 0-6M 2942 99.6 60° •,,� `�,'• 60° 25° 2241 0-90° 2953 100.0 411111.t' Total 35° 1093 Luminaire 0-180° 2953 100.0 50° W�..�� 50° 45° 196 55° 23 40° 30° 20° 10° 0° 10° 20° 30° 40° 65° 7 °°---- ,Y 45° 75° 2 FOOTCANDLE VALUES 45° 0 �� 90° 85° 0°aiming angle-horizontal surface 90° 0 F a Distance Beam Center from source Diameter Beam(FC) s s 4' 5.0' 182 6' 7.5' 81 s rc 8' 10.0' 45 10' 12.5' 29 Footcandle results based on AGI32;Reflectances=0/0/0;LLF=1 Go to www.focalpointlights.com for additional photometric data. L/THON/A L/GHT/NG® Number Notes FEATURES&SPECIFICATIONS INTENDED USE—Suitable for applications requiring both exit sign and unit equipment.Attractive,8" tall,streamlined design is great for above-the-door applications and other tight fits.Optional high-output Type EXIT EGRESS version with remote lamps are ideal for emergency egress lighting.Certain airborne contaminants can diminish integrity of acrylic and/or polycarbonate.Click here for Acrylic-Polycarbonate Compatibility table for suitable uses. CONSTRUCTION—Engineering-grade thermoplastic housing is impact-resistant,scratch-resistant and corrosion-proof.UL94V-0 flame rating.UV-stable resin resists discoloration from natural and man-made 1 QUANTUM®sources. ' . Rugged unibody housing snaps together with no additional fasteners.Faceplate and back cover are inter- Thermoplastic Exits changeable on housing.Positive snap-fit tabs hold faceplate securely,yet are easily removable for lamp compartment access.Universal,directional chevron inserts are easily removed and reinserted. Uniform graphics illumination without shadows or hot spots.Letters are 6"high with 3/4"stroke,with 100 ft. viewing distance rating based upon U1924 standard. ` H Q M L E D LEDs mounted on primary circuit boards for sign illumination.Low-energy LED lamp in sign operates in normal (AC input)and emergency(DC input)modes. Low-profile,integrated test switch/pilot light.Easily viewed bright red status indicator. EXIT Unique track-and-swivel arrangement permits full range of direction of lamp head adjustment.Universal i-box mounting pattern.Tool-less access for maintenance.Conduit entry position on top of unit. LED Lamp Head U.S.Patent No.6,848,798;6,499,866;6,142,648;5,797,673;D379,373;5,526,251;D484,272; Nickel-Cadmium Battery D473,672;5,611,163;5,646,502. OPTICS—Twin LED lamp heads operate in emergency(DC input)mode with 12 series-parallel white LEDs HO RO in each head.Provides redundant light sources to ensure emergency lighting performance.The typical life of the exit LED lamp is 10 years. ELECTRICAL—Dual-voltage input capability(120/277V).Edge connector on printed circuit board ensures long-term durability. Current-limiting charger maximizes battery life and minimizes energy consumption.Provides low operating costs. Short-circuit protection—current-limiting charger circuitry protects printed circuit board from shorts. INSTALLATION—Top,end or back mounting.Housing snaps to canopy with positive-locking tabs.Cam Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient locking pin secures housing to canopy. temperature. Easily removed mounting knockouts.Conduit entry knockout for 1/2"flexible conduit.1-box pattern on back panel. Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages.Prevents over/ LISTINGS—UL damp location listed standard 50°-104°F(10°-40°C).Meets UL 924,NFPA 101(current Life undercharging that shortens battery life and reduces capacity. Safety Code),NEC and OSHA illumination standards. Altered charger input minimizes charge voltage ripple and extends battery life. WARRANTY—5-year limited warranty.(Battery is prorated).Complete warranty terms located at AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from www.AcuityBrands.com/CustomerResources/Terms and Conditions.aspx. deep discharge. Note:Actual performance may differ as a result of end-user environment and application. Single multi-color LED indicator to display two-state charging,test activation and three-state diagnostic test. All values are design or typical values,measured under laboratory conditions at 25°C. Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Specifications subject to change without notice. Self-diagnostic testing for 30 seconds every 30 days,30 minutes at 180-day interval,and 90 minutes annually. Diagnostic evaluation of LED light source,AC-to-DC transfer,charging and battery condition. Battery:Sealed,maintenance-free nickel-cadmium battery delivers 90-minute capacity to emergency lamps.Two-state contstant-current charge maximizes battery life and automatically recharges after battery discharge.Low-voltage disconnect prevents excessively deep discharge that can permanently damage the bat- tery.Optional high-output battery to power both local and optional LED remote lamp heads simultaneously. ORDERING INFORMATION Lead times will vary depending on options selected.Consult with your sales representative. Example:LHQM LED G LHQM LED Lamp type Housing color LHQM Stencil face, LED Two (blank) White R Red HO High-output Ni-cad battery NOM Meets Mexican standards' single face plate 1.5W/9.6V B Black G Green HO RO High-output option,less lamp heads NOM SALIDA Salida signage(non-UL)' with extra face white LED plate SD Self-diagnostics Accessories:Orderasseparatecatalog number. Notes ELA QL0309SD Single LED indoor remote head,white,self-diagnostics 3,4,8 ELA WG3 Wireguard,30"Wx13-1/2"Hx6"De 1 Available in blackohitr e.N.Cotandansult actoryforoptions. 2 Only available in white.NOM standard. ELA T Q L0309 SD Twin LED indoor remote head,white,self-diagnostics 3,4,5 ELA WG2M Wireguard,21-1/4"W x 15"H x 12"V 3 Only compatible with self-diagnostic option.(ex:H0 SD) ELA QWP L0309 SD Single LED weather-proof remote head,gray,self- ELA LQMUS12 12"white stem kit' 4 Also available in black.Add"B"after ELA to order black diagnostics 3,4$ finish.Example:ELA B Q L0309. ELA T QWP L0309 SD Twin LED weather-proof remotehead,gray,self- ELA LEDM12 Single B9 6 SeOnlypecsheetble HOoption.SeespecsheetELA-Q-LED. p 9 p" 6 See spec sheet ELA-WG. diagnostics 3.45 7 See spec sheet ELA-Stemkits. ELA Q L0309 Single LED indoor remote head,white4,s ELA LED T M12 Twin LED remote lamp8'9 8 See spec sheet ELA LED(Contractor Select LED Remotes). ELA T Q L0309 Twin LED indoor remote head,white4.5 ELA LED WP M12 Single LED Weather proof remote lamp 8,9 9 Not available with SD. ELA QWP L0309 Single LED weather-proof remote head,gray4.5 ELA LED T WP M12 Twin LED Weather proof remote lamp 8,9 ELA T QWP L0309 Twin LED weather-proof remote head,gray4'5 WHEN SHOWN EMERGENCY LHQM-LED LHQM LED QUANTUM° Exit/Unit Combo SPECIFICATIONS MOUNTING All dimensions are inches(centimeters). Electrical Shipping weight:3.6 lbs.(1.6 kgs.). Face Primary Circuit Typical Supply Max Max 141 LED life' voltage amps watts (48.99)) O 120 .05 4.3 Red and green LED 10 years 7 ,- 277 .03 4.3 4 > [I � (20.3) BATTERY J Ni-Cad 12 Test switch/ Voltage Typical: Typical Maintenance' Optimum 4 (30.5) pilot light Shelf life life temperature 9.6 3 years 7-9 years none 50-1047 Top End (10-40°C) I 4-3/4 J 1 Based on continuous operation. x(11.1) 1/2"flexibleconduitentryknockout ■_. 1 2 At 77°F(25°C). n��r 3 All life safety equipment,including emergency lighting path of egress,must be maintained,serviced and tested I�pIlII T�) in accordance with all National Fire Protection Association and local codes.Failure to perform the required , 9 5-5/8 (ExIT, i�• maintenance,service or testing could jeopardize the safety of occupants and will void all warranties. (22.9) (51T. I ��_ 4 Optimum ambient temperature range where unit will provide capacity for 90 minutes.Higher and lower lilt y temperatures affect life and capacity. a=ul s 5. Battery life is negatively impacted by many variables including temperature,charging rates,number of cycles —12-1/4I— and deep discharges due to long periods of time without AC power. (5.7) Backplate Universal knockout Re • AAA �;`�� pattern for various B standardt-boxes Standard Combo/high-output Combo/high-output(HO) Combo l`' 4 (20.3) unit battery(HO) and no heads(RO) —__ NA NA 3W 6W "012) 6 (15.2) 12 (30.5) LAMP PHOTOMETRICS QUANTUM LED SERIES—SINGLE COVERAGE .$ .4 3W Total White LEDs .0.s.z. FII,Oe so. 1 FC average Using a single unit at a typical 7.5'mounting height delivers an average illuminance of 1.0 FC %s= — over a distance of 24'on a 3'path of egress and 18'on a 6'path of egress. \ ----- 1' ::r...• 3' .... ..:Pit 5�,lir Z. Example of single LHQM LED exit Example of single LOOM LED exit illuminating a 3'path of egress illuminating a 6'path of egress ..p��2a, eg��2p. _ 1F(average ems. —_A.�� 1Kaverage qtlk QUANTUM LED SERIES—MULTIPLE COVERAGE __ fit::.—___ `'----___ 3WTotalWhiteLEDs _ — — —Usi ng multiple units at a typical 7.5'mounting height delivers 25'center-to-center spacing on a ------------------------------- 3' = ----- '"=%_s _3'pathofegressand20'center-to-center spacing on a 6'path of egress. — 'may..-- "===.:—sii'''—s' Example of multiple LHQM LED exits Example of multiple LHQM LED exits illuminating a 3'path of egress illuminating a 6'path of egress EXTENDED RUN-TIME FOR HIGH-OUTPUT EXITS Product Run time LHQM LED HO(no remotes) 3.8 hours LHQM LED HO RO(no remotes) 7.5 hours IA L/THON/A LIGHT/NG® LHQM-LED EMERGENCY: One Lithonia Way Conyers,GA 30012 Phone:800-334-8694 www.lithonia.com ©2012-2017 Acuity Brands Lighting,Inc. All rights reserved.Rev.08/02/17 alog I� L/T/ION/A L/GHT/NG' Camber Notes FEATURES&SPECIFICATIONS INTENDED USE—Built on the compact,low-profile Z strip channel,this LED strip offers long Type FIXTURE TYPE F maintenance-free life,several color temperatures,lumen outputs and lengths.Ideal for new construc- tion and retrofit applications in T5 and T8 lengths.Ideal for uplight and downlight in commercial,retail, manufacturing,warehouse,cove and display applications.Certain airborne contaminants can LED Striplight diminish the integrity of acrylic and/or polycarbonate.Click here for Acrylic-Polycarbonate Compatibility table for suitable uses. CONSTRUCTION—Compact-design channel and cover are formed from code-gauge cold-rolled steel. z iii,! Easy to install row aligner included for continuous row mounting. Finish:Paint options include high-gloss,baked white enamel(WH),galvanized(GALV),matte black(MB) and smoke gray(SKGY).Afterfabrication,five-stage iron phosphate pre-treatment ensures superior paint SERIES adhesion and rust resistance. OPTICS—Standard diffuse snap on/snap off lens eliminates pixels,improves uniformity and minimizes 24",48"and 96"Lengths glare.L/LENS option available. ELECTRICAL—L70>60,000hours.Utilizes high-output LEDs integrated on a two-layer circuit board, + IL . {J G�C{� ensuring cool-runningoperation.Optional internal pluggablewiring harnessforreduced laborcostin row L mounting applications.(See PLR_ordering information on page 3.)Electronic LED driver is rated for 75 q,^e nrEo input watts maximum(see Operational Data on page two for actual wattage consumption),multi-volt input and 0-10V dimming standard.This fixture is designed to withstand a maximum line surge of 1.5kV at 0.75kA combination wave for indoor locations,for applications requiring higher level of protec • - tion additional surge protection must be provided. LEDs provide nominal 80 CRI at 3000 K,3500 K,4000 K,or 5000 K. L/Lens Lumen output up to 2,000 lumens per foot.In 86°F(30°C)ambient environments.Luminaire should be installed in applications where ambient temperatures do not exceed 86°F(30°C). INSTALLATION—Tool-less channel cover for easy installation. Fixture may be surface mounted(with or without ZSPRG hanger),pendant or stem mounted with appropriate mounting options.Three-point aligner locks in place for easy continuous row mounting. LISTINGS—(SA certified to US and Canadian safety standards.For use in damp locations between -4°F(-20°C)and 86°F(30°C). Lensed DesignLights Consortium®(DLC)qualified product.Not all versions of this product may be DLC quali- fied.Please check the DLC Qualified Products List at www.designlights.org to confirm which versions are qualified. WARRANTY—5-year limited warranty.Complete warranty terms located at: www.acuitybrands.com/CustomerResources/Terms and conditions.aspx Note:Actual performance may differ as a result of end-user environment and application. All values are design or typical values,measured under laboratory conditions at 25°C. Specifications subject to change without notice. ��* Capable Luminaire This item is an A+capable luminaire,which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning. • All configurations of this luminaire meet the Acuity Brands'specification for chromatic consistency • This luminaire is part of an A+Certified solution for nLight®or XPoint'""Wireless control networks marked by a shaded background* To learn more about A+,visit www.acuitybrands.com/aplus. *See ordering tree for details INDUSTRIAL ZL1 N Page 1 of 6 ZL1N LED Striplight A+Capable options indicated by this color background. ORDERING INFORMATION Lead times will vary depending on options selected.Consult with your sales representative. Example:ZL1NL483000LMFST MVOLT 40K80CRIWH Nominal lumens' A voltage MIN ZL1N LED striplight L24 24" SMR Symmetric 1500LM 1,5001umens3 FST Snap on frosted,diffuse MVOLT 120-277V 2500LM 2,500 lumens' L/LENS No diffuser 120 120V 3500LM 3,500lumens SBL FST Straight blade louver with snap 208 208V L46 46" ASR Asymmetric(L48 only) 3000LM 3,000 lumens on frosted,diffuse 240 240V L48 48" SMR Symmetric 5000LM 5,000 lumens 277 277V 7000LM 7,000lumens 347 347V4 TZL1N LEDstriplight L92 92" SMR Symmetric 6000LM 6,000lumens 480 480V4 L96 96" 10000LM 10,000 lumens 14000LM 14,000 lumens Color temperature Color rendering index Options Paint finish 30K 3000 K 80CRI 80 CRI PLR Plug-inwirings,6 Cordsets:10 WH White 35K 3500 K 90CRI 90 CRI PLR1LVG Plug-in wiring-low voltage' CS1W Straight plug,120V GALV Galvanized 40K 4000 K E7W Emergency battery pack,7W CS3W Twist-lock,120V MB Matte black 50K 5000K (not available for California)'.8 CS7W Straight plug,277V SKGY Smoke gray 2E7W Two Emergency battery packs,7W CS11W Twist-lock,277V (not available for California)'$'' E1OWLCP Emergency battery pack,l0W CS25W Twist lock,347V Linear Constant Power,CA Title 20 CS97W Twist-lock,480V compliant'•$ CS93W 600V SEOOW white cord,no plug 2E1OWLCP Two Emergency battery packs, (no voltage required) 10W Linear Constant Power,CA Title 20 Compliant',89 E15WLCP Emergency battery pack,15W Linear Constant Power,CA Title 20 compliant'•$•' OUTEND Cord set to exit endplate of fixture Notes Accessories:Order as separate catalog number. 1 Optional.Reflectors ship separately. 2 See Operational Data on page 3 for actual lumens. HC36 Hanger chain,36" 3 Not available with 0-10y dimming option. ZACVH Aircraft cable 10'(one pair) 4 Not available with L24,24"fixture.347V and 480V utilize a ZLANGBKT Luma-tilt'""angle bracket for shelf or ledge mounting only step-down transformer. NPP16D nLight switching/dimming module 5 See ordering information on page 5. LSXR Sensor Switch'LSXR occupancy sensor' 6 Not available with cordsets. ZSPRG For 15/16"T-grid only 7 Not available with L24,24"fixture.See spec sheet PS1055LCP, WGZ24 24"wireguard,white PS1555LCPand PS750Lfor more information. WGZ48 48"wireguard,whiten 8 Must specify voltage.120,208,240 or 277V. ZLR L24 SYM UPL WH 24"symmetric reflector with uplight,white finish 9 Only available with the 8'(96")fixtures. 10 Cordsets exit back of fixture unless OUTEND option is specified. ZLR L24 SYM WH 24"symmetric reflector,white finish 11 Order 2 for tandem double length fixtures(TZL1N).Must ZLR L46 SYM UPL WH 46"symmetric reflector with uplight,white finish specify voltage(not required when ordering CS93W). ZLR L46 SYM WH 46"symmetric reflector,white finish ZLR L48 ASY WH 48"asymmetric reflector,white finish ZLR L48 SYM UPL WH 48"symmetric reflector with uplight,white finish ZLR L48 SYM WH 48"symmetric reflector,white finish ZLR L92 SYM UPL WH 92"symmetric reflector with uplight,white finish ZLR L92 SYM WH 92"symmetric reflector,white finish ZLR L96 SYM UPL WH 96"symmetric reflector with u plight,white finish ZLR L96 SYM WH 96"symmetric reflector,white finish INDUSTRIAL ZL1N Page 2 of 6 ZL1N LED Striplight OPERATIONAL DATA Delivered Lumens 3000 Delivered Lumens 3500 Delivered Lumens 4000 Delivered Lumens 5000 Nominal Length K CCT @ 77°F(25°C) K CCT @ 77°F(25°C) K CCT @ 77°F(25°C) K CCT @ 77°F(25°C) Wattage lumen ambient temperature ambient temperature ambient temperature ambient temperature @ Comparable Light Source package (inches) 120V/277V 80 CRI 90 CRI 80 CRI 90 CRI 80 CRI 90 CRI 80 CRI 90 CRI 1500LM 24 1738 1409 1777 1467 1804 1494 1871 1528 15 1-lamp17WT8 2500LM 24 2265 1846 2315 1900 2351 1947 2438 1991 19 1-lamp 17W18 3500LM 24 3586 2924 3666 3026 3723 3084 3860 3152 31 1-lamp 32W T8,1-lamp 54W T5H0,50W HID -a 3000LM 46or48 3172 2586 3243 2677 3293 2728 3415 2788 25 1-lamp 32W T8,1-lamp 54W T5H0,50W HID cu d 5000LM 46 or 48 4417 3601 4515 3727 4585 3798 4754 3882 34 2-lamp 32W T8,1-lamp 54W T5H0,70W HID J - 7000LM 46or48 6535 5328 6681 5515 6785 5619 7035 5744 52 3-lamp 32W T8,2-lamp 54W T5H0,100W HID 6000LM 92or96 6561 5349 6708 5537 6812 5642 7063 5767 48 3-lamp 32W T8,2-lamp 54W T5H0,100W HID 10000LM 92 or 96 8687 7082 8881 7331 9019 7470 9351 7636 68 4-lamp 32W 18,2-lamp 54W T5H0,100W HID 14000LM 92 or 96 12457 10513 12735 10665 12933 10711 13409 10949 104 4-lamp 32W T8,3-lamp 54W T5H0,150W HID 1500LM 24 1881 1534 1923 1588 1953 1618 2025 1654 15 1-lamp 17W18 2500LM 24 2452 1999 2506 2069 2545 2108 2639 2155 19 1-lamp 17W18 3500LM 24 3882 3165 3969 3276 4031 3338 4179 3412 31 1-lamp 32W T8,1-lamp 54W T5H0,50W HID c 3000LM 46or48 3434 2800 3511 2898 3565 2953 3697 3019 25 1-lamp 32W T8,1-lamp 54W T5H0,50W HID C.; d 5000LM 46 or 48 4781 3898 4888 4035 4964 4111 5147 4203 34 2-lamp 32W T8,1-lamp 54W T5H0,70W HID c 7000LM 46 or 48 7075 5768 7233 5971 7345 6083 7616 6219 52 3-lamp 32W T8,2-lamp 54W T5H0,100W HID 6000LM 92or96 7103 5791 7261 5995 7374 6108 7646 6243 48 3-lamp32WT8,2-lamp54WT5H0,100WHID 10000LM 92 or 96 9404 7667 9614 7937 9764 8087 10123 8266 68 4-lamp 32W 18,2-lamp 54W T5H0,100W HID 14000LM 92 or 96 13485 10994 13786 11381 14001 11596 14516 11853 104 4-lamp 32W T8,3-lamp 54W T5H0,150W HID DIMENSIONS PALLET DIMENSIONS All dimensions are shown in inches(centimeters)unless otherwise noted. I Approximate Fixtures per Approximate pallet dimensions Length Specifications subject to change without notice. weight pallet (LxWxH) L24 7lbs. 408 46"X51"X3211/16" L46 11 lbs. 176 46"X 51"X 32 1/16" L48 12 lbs. 176 46"X 51"X 313/8" L92 22 lbs. 176 46"X 981/2"X 31 1/16" L96 24 lbs. 176 46"X 981/2"X 31 1/16" 48 48 2-1/8 (122.0) (122.0) 2-1/8 (5.4) (5.4) 00 8 $e i' (244.0( 1 24 24 2-1/8 161.01 (61.0) 2-1//8 (5.4) (5.4) 15.41 48 (122.0) 1 2-3/16" 2-1/8" (5.56) (5.39) 111.111.II: 2-1/8 (312 (305) 2-1/8 (539) cp - 2-1/8" II .. .... (5.4) 15.41 (5.39) - L $ D O g,9( f - LFL I (61 0) PHOTOMETRICS Please see www.lithonia.com INDUSTRIAL ZL1 N Page 3 of 6 ZL1N LED Striplight REFLECTORS(Optional) L24 Reflector — — 3.67 24.00 L 10.70 —J L48 Reflector 3L( 48.00 10.70 L96 Reflector • — I 3.67 96.00 PHOTOMETRICS Please see www.lithonia.com INDUSTRIAL ZL1 N Page 4 of 6 ZL1N LED Striplight PRODUCT INFORMATION Wiring Advanced plug-in system with three-circuit capability.Available on industrial and strip products and a variety of architectural products mounted in continuous rows.1,2,3 and 4-lamp fixtures.PLR22(2-cir- cuit)and PLR33(3-circuit)crossover harness switches hot circuit serving next fixture in row.ReducesPLR fixture types on job for alternating circuit applications(see example below.) Easy one-step installation,saves up to 35%on labor costs.Expanded switching flexibility helps save energy. _ Rows can be 50%longer with two-circuit systems.Polarized,lock-together nylon connectors prevent miswiring in the field.#12 THHN conductor,rated 600V,90°C.White neutral wire included.Grounding Advanced 3-Circuit Plug-In accomplished by fixture in-row connectors. CSA certified systems available with up to 2 circuits.G ground required. Note:Specifications subject to change without notice. ORDERING INFORMATION Lead times will vary depending on options selected.Consult with your sales representative. Number of hot wires PLR (blank) Not required for 22 or 33 Circuits to which ballast is connected B Red wire LV Low-voltage dimming (blank) No ground in PLR PLR22 1 Black (blank) Not required for 22 or 33 C Blue wire G Ground.Maximum2circuits PLR33 2 Black and red A Black wire 3 Black,red and blue Typical Applications TYPICAL APPLICATIONS • Multiple circuit and single-circuitforlongercontinuousrows PLR3C PLR3C PLR3C PLR3C PLR 26 PLR 2 B PLR 2 B PLR 2 B PLR 1 PLR 1 PLR 1 (All PLR22) • Multiple-circuit with alternating fixtures on separate circuits, Circuit A Circuit B Circuit A Circuit B Circuit A Circuit B Circuit A Circuit B Circuit A Circuit B Circuit A 2-circuit(PLR 22)and 3-circuit(PLR 33) (All PLR33) • Multiple circuit with night-lights located along row as desired CircuitA CircuitB CircuitC CircuitA CircuitB CircuitC CircuitA CircuitB CircuitC CircuitA Circuit B PLR3A PLR3A PLR3A PLR3C PLR 3B PLR 3B PLR 3B PLR3C PLR3A PLR3A PLR3A PRODUCT INFORMATION Passive Infrared Indoor Occupancy Sensor A standard occupancy time delay is also present to ensure lights turn off(once minimum on timer has also elapsed)ifoccupancy is detected. This timer is factory set at 10 minutes to promote energy savings,but is adjustable between 30 seconds LSXR and 30 minutes.These adjustments maybe done through the unit's push-button. FEATURES • Four interchangeable lenses-high mount 360°,low mount 360°,high mount aisleway,and small motion 360°. Single Relay • Integrated mounting bracket drops lens down 3"from chase nipple-no bracket accessory required. :Ac;tyc rros • 100%digital PIR detection-provides excellent RF immunity AZEZIr Note:Specifications subject to change without notice. ORDERING INFORMATION Lead times will vary depending on options selected.Consult with your sales representative. Example:LSXR 10 ADC HVOLT 30M LSXR Dimming/photocell LSXR Passivelnfraredlndoor (blank) No lens 610 High and low mount 360° (blank) None Occupancy Sensor 6 High mount,360' 650 High mount 360°and aisleway HL High/low occupancy operation 10 Low mount,360° 3PK High and low mount 360°and aisleway P Switching photocell(on/off) 50 High mount aisleway 4PK All lenses ADC Dimming and switching photocell 9 Small motion,360° ANL Dimming and switching photocell with high/low occupancy operation Max dim level Min dim level Lead length Temp humidity M. Default time delay (blank) 120-277 VAC (blank) 10 VDC (blank) Minimum dimming level of ballast (blank) 14" (blank) None (blank) 10 minutes(with minimum (MVOLT) 9H 9 VDC 1V 1 VDC 42L 42" LT Low temperature 15 minutes on time) HVOLT 347-480 VAC 8H 8 VDC 2V 2 VDC 5M 5 minutes(LED only) 7H 7 VDC 3V 3 VDC 15M 15 minutes 4V 4VDC 20M 20 minutes 5V 5 VDC 30M 30 minutes 6V 6 VDC For additional information see www.lithonia.com INDUSTRIAL ZL1 N Page 5 of 6 ZL1N LED Striplight OPTIONS AND ACCESSORIE The Z Series fixture offers numerous options for almost every electrical and optical component,including a long list of field-installable accessories. HANGER CHAIN Z SPRING HANGER 36"chain with Y hanger. Snap'n'lockdesignrequiresnofastenersandcan • , be used on T-grid ceiling or universal mounting r\\Li\ r; Order as: J systems. 1' HC36 a f -, r Order as: f zJ ZSPRG ZACVH HANGER ANGLE MOUNTING BRACKET 10'Aircraft cable with Yhanger. I/ Luma-tilt'"angle bracket ships as a pair / Order as: J. :;i. a` Order as: ZACVH ' .;I ` • "----__.„„l � w ZLANGBKT J r"Y ..._„......_ _r WIRE GUARD -„l' Order as: ,001-t * y,,, WGZ24 sieri ftii02,-; WGZ48 Ir. L/THON/A L/GHT/AIG® ZL1N INDUSTRIAL: One Lithonia Way,Conyers,GA 30012 Phone:800-315-4963 www.lithonia.com ©2013-2017 Acuity Brands Lighting,Inc.All rights reserved.Rev.10/04/17 Page 6 of 6