Loading...
HomeMy WebLinkAboutDRB18-0051_conceptual documents_1528925448.pdfMEMORANDUM To: Vail Planning and Environmental Commission From: Vail Department of Public Works and Transportation Date: March 15, 2018 RE: Narrative for Conditional Use Permit for Proposed Ford Park Softball Field Shelter. The Vail Town Council has budgeted funds for improvements to Ford Park to design a permanent shelter at the area referred to as the Softball Field Spectator Plaza. This is the area where the softball infields of the west and center fields come together. The purpose of the proposed shelter is to provide sun, rain, and lightning protection for athletes and spectators utilizing the sport fields at Ford Park in this heavily used location. The existing shelter of the covered picnic area at the east concession/restroom facility and the roof overhang of the west maintenance/restroom facility offer in adequate protection or are too great a distance from the location where many park users congregate. The proposed shelter consists of a permanent steel frame on concrete foundation with wood fascia and column wraps with stone bases. The roofing will be a Live Roof System matching the roof of the near-by West Restroom and Maintenance Building. All architectural elements will match those of this building. The roof slope will be approximately 2:1. The proposed shelter covers the majority of the spectator plaza area. The footprint is approximately 1429 square feet. The maximum height is 21’-1 ½”. Preliminary Drawings are included with the submittal. Final architectural and structural design has been begun. Construction is scheduled for the fall of 2018. PEAKED ROOF 2:1 ROOF SLOPE SOFFIT HGT = 12'-10" EAVE HGT = 14'-10" PEAK HGT = 21'-1 1 2" FASCIA DEPTH = 2'-0" DESIGNED BY DATE CHECKED BY DRAWN BY SHEET TOV JOB NO. FILE NAMETown of VailDepartment of Public Worksph 970.479.2158fax 970.479.2166www.vailgov.com1309 Elkhorn DriveVail, CO 81657SCALE Softball Shelter Deisgn Options2/8/18 NONE SP-2FORD PARK - SOFTBLL FIELD SHELTER 30" C.I.P. CONCRETE RETAINING WALL WITH SUBDRAIN SHELTER PERIMETER50' X 28' APPROXIMATE SYNTHETIC TURF SOFTBALL INFIELD 6" CONCRETE PAVEMENTTYPICAL THROUGHOUT 8' CONCRETE BIKE PATH INTERSTATE 70 FRONTAGE ROADSTEEP NATIVE GRASS HILLSIDE PORTABLE ALUMINUM BLEACHERS MUST FIT BENEATH THE SHELTER BETWEEN COLUMNS LANDSCAPE AREAS TYPICAL PORTABLE ALUMINUM BLEACHERSMUST FIT BENEATH THE SHELTER BETWEEN COLUMNS COLUMN BASE AND FOOTINGTYPICAL OF 4 LOCATIONS DESIGNED BY DATE CHECKED BY DRAWN BY SHEET TOV JOB NO. FILE NAMETown of VailDepartment of Public Worksph 970.479.2158fax 970.479.2166www.vailgov.com1309 Elkhorn DriveVail, CO 81657 SCALE Softball Shelter Site Plan2/8/18 1"= 10' SP-1FORD PARK SOFTBALL FIELD SHELTER FLAT ROOF OPTION SOFFIT HGT = 12'-10" EAVE HGT = 14'-10" FASCIA DEPTH - 2'-0" PEAKED ROOF OPTION 4:1 ROOF SLOPE SOFFIT HGT = 12'-10" EAVE HGT = 14'-10" PEAK HGT = 21'-1 1 2" FASCIA DEPTH = 2'-0" PEAKED ROOF 2:1 ROOF SLOPE SOFFIT HGT = 12'-10" EAVE HGT = 14'-10" PEAK HGT = 21'-1 1 2" FASCIA DEPTH = 2'-0"