Loading...
HomeMy WebLinkAboutDRB18-0157_Approved Plans_1530048648.pdfProject number Date Drawn by 4/30/2018 11:17:56 AMA0 COVER VAIL ROWHOUSES, VAILCOLORADOROW HOUSE 1104/30/2018 BRM No. Description Date 2 DRB SUBMITTAL 26 DEC 16 3 AMENDED DRB SUBMITTAL I 02 AUG 17 5 AMENDED DRB SUBMITTAL II 28 NOV 17 6 AMENDED DRB SUBMITTAL III 30 APR 18 1. DO NOT SCALE DRAWINGS. 2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR AREAS. 4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED. 5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS. 6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR TYPES. 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS. 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL RESIDENTIAL CODE. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN UBC AND ALL LOCAL AND REGIONAL CODES. 11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL PROBLEMS WITH THESE SURFACES. 14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN APPROVAL. 15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. 16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO THE SITE. 18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE. 19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER. 20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT. GENERAL Code: INTERNATIONAL RESIDENTIAL CODE 2015 Zoning: VAIL VILLAGE TOWNHOUSE DISTRICT Occupancy Classification: TYPE R DIV. 3 (SPRINKLERED) PROJECT PROJECT ARCHITECTS: K.H. WEBB ARCHITECTS 710 W. LIONSHEAD CIRCLE, UNIT A VAIL, CO 81657 PH. 970.477.2990 CONTACTS: KYLE H. WEBB kyle@khwebb.com BRANDON MEYER brandon@khwebb.com DESIGN CONSULTANT: TREACY & EAGLEBURGER ARCHITECTS 3335 CONNECTICUT AVENUE, NW WASHINGTON, DC 20008 PH. 202.362.5226 CONTACTS: PHILLIP EAGLEBURGER phil@treacyeagleburger.com GENERAL CONTRACTOR: SRE BUILDING ASSOCIATES 23698 HIGHWAY 24, SUITE D-2 MINTURN, COLORADO 81645 MAIL: PO BOX 6376 VAIL, COLORADO 81658 PH. 970.845.6359 CONTACT: STEVE ELICKER steve@srebuilds.com STRUCTURAL ENGINEER: MONROE-NEWELL ENGINEERS, INC. 70 BENCHMARK ROAD, SUITE 204 AVON, COLORADO 81620 MAIL: PO BOX 1567 AVON, COLORADO 81620 PH: 970-949-7768 CONTACT: PETER MONROE pmonroe@monroe-newell.com GEOTECHNICAL ENGINEER: HP KUMAR GEOTECHNICAL, INC 5020 COUNTY ROAD 154 GLENWOOD SPRINGS, CO 81601 PH: 970-945-7988 CONTACT: STEVE PAWLAK, P.E. hpkglenwood@kumarusa.com MECHANICAL/ELECTRICAL ENGINEER: BG BUILDING WORKS 222 CHAPEL PLACE, UNIT AC-201 AVON, COLORADO 81620 PH: 970-949-6108 CONTACTS: DAN KOELLIKER LANDSCAPE ARCHITECT: CERES LANDSCAPE ARCHITECTURE PO BOX 2134 EAGLE, CO 81631 PH: 970-949-3286 CONTACT: SCOTT SONES SURVEYOR: EAGLE VALLEY SURVEYING P.O. BOX 1230 EDWARDS, CO 81632 970.949.1406 PH: 303-565-4963 CONTACT: STAN HOGFELDT 1 A4.1A Detail Area EL: 0'- 1 A4.00 1 A3.0 Elevation Section Cut 1 A-2.0 1 Large Area Detail 12/31/1999 1 Material Revision 1 A4.1A Detail Cut Grid Bubble Revision Cloud Elevation VAIL ROW HOUSES - NUMBER 11 303 GORE CREEK DRIVE, UNIT 11 VAIL, COLORADO 81657 AMENDED DRB SUBMITTAL III 04.30.18 A0 - COVER A1 - SITE, PROPOSED ELEVATIONS, GRFA A2a - CREEK LEVEL PLAN A2b - STREET LEVEL PLAN A2c - SECOND LEVEL PLAN A2d - THIRD LEVEL PLAN A3 - BUILDING SECTION & ROOF PLAN DRAWING SYMBOLS A4 - PROPOSED COLORS A4a - SOUTH ELEVATION A4b - NORTH ELEVATION DRB APPROVED 6/26/2018 12:00:00 AM 1 - CREEK LEVEL 8,168' - 3 1/4" 2 - STREET LEVEL 8,178' - 1 3/4" 3 - SECOND LEVEL 8,188' - 3 5/8" 4 - THIRD LEVEL 8,198' - 3 1/8" 2 2 A3 36" HIGH GUARD RAIL WITH 4" SPACE BETWEEN CROSS MEMBERS RETRACTABLE AWNING UTILITY CLOSET IN FOREGROUND 3 1 2 2 A3 208 SF EXPOSED 124 SF 112 SF 166 SF 610 SF 208 SF = 34% UNIT 11 - EXISTING BASEMENT WALL AREA: 221 SF EXPOSED 506 SF 103 SF 1,452 SF 327 SF = 23% UNIT 11 - PROPOSED BASEMENT WALL AREA: EXISTING SQUARE FOOTAGE: LOWER LEVEL: 430 SF (34% = 146 SF) STREET LEVEL: 1108 SF 2ND LEVEL: 1126 SF 3RD LEVEL: 415 SF TOTALS: 3079 SF ACTUAL EXIST. 2795 SF ALLOWABLE EXIST. SITE AREA: 2337 SF X ..55 (VVTHD SITE FACTOR): ACTUAL SITE COVERAGE: 1126 SF EXISTING APPROVED SQUARE FOOTAGE: 1255 SF (18% = 226 SF) 1288 SF 1154 SF 641 SF 4338 SF ACTUAL APPROVED 3142 SF ALLOWABLE APPROVED 1285 SF ALLOWED COVERAGE 1276 SF APPROVED COVERAGE PROPOSED SQUARE FOOTAGE: 1265 SF (23% = 291 SF) 1264 SF 1173 SF 660 SF 4362 SF ACTUAL PROPOSED 3142 SF ALLOWABLE PROPOSED 1285 SF ALLOWED COVERAGE 1285 SF PROPOSED COVERAGE 516 SF 106 SF EXPOSED COMBINED LANDSCAPE CALCULATION FOR UNIT 11 & 12: SITE AREA: 5274 SF X .3 = 1582 SF REQUIRED LANDSCAPE AREA BUILDING FOOTPRINT: 2718 SF AVAILABLE REMAINING SITE: 2556 SF PROPOSED SOFTSCAPE: 600 SF + 129 SF + 287 SF + 55 SF = 1071 SF HARDSCAPE (2556 x.2): 511 SF TOTAL PROPOSED LANDSCAPE: 1582 SF SPA CREEK LEVEL STREET LEVEL PROVIDE LIMITED DISTURBANCE AND EROSION CONTROL FENCE NEW HEATED DRIVEWAY W/ SANDSET PAVERS HEATED DRIVEWAY WITH IN TOV ROW WILL BE ON A SEPARATE ZONE W/ APPROPRIATE MARKINGS IDENTIFYING ITS LOCATION AT THE CONTROL VALVE BOX 11 5'-0"BUILDING FOOTPRINT SOFTSCAPE AREA WINDOW WELL TRASH RAISED PLANTER 129 SF COMBINED SOFTSCAPE 600 SF RAISED PLANTERS 55 SF COMBINED SOFTSCAPE 287 SF TRASH Project number Date Drawn by 6/18/2018 11:59:55 AMA1 PROPOSED ELEVATIONS & GRFAVAIL ROWHOUSES, VAILCOLORADOROW HOUSE 1106/18/2018 BRM No. Description Date 2 DRB SUBMITTAL 26 DEC 16 3 AMENDED DRB SUBMITTAL I 02 AUG 17 4 AMENDED DRB SUBMITTAL CORRECTION 25 AUG 17 5 AMENDED DRB SUBMITTAL II 28 NOV 17 6 AMENDED DRB SUBMITTAL III 30 APR 18 1/4" = 1'-0"3 PROPOSED SOUTH ELEVATION 1/4" = 1'-0"2 PROPOSED NORTH ELEVATION 1/8" = 1'-0"1 SITE PLAN DRB APPROVED 6/26/2018 12:00:00 AM 22'-7" 21'-3" W/D 12 3 4 5 6 7 8 EDGE OF DECK ABOVE UP 7' 4-1/2" CEILING HT.6' 11" CEILING HT T.O.FIN FLR 8171'-3 5/8" LEVEL ONE UNEXCAVATED UP 3 1 A F C E 2 8,168' - 3 1/4" 8,168' - 3 1/4" BEDROOM BATH CL ELEV HALL HALL A4b 3 2 A3 ADDITION ADDITION EXTERIOR STAIR CREATED IN EASEMENT AGREEMENT (RN 201717959) B D WINDOW WELL A1 IN GROUND SPA MECH MECH / STOR SPARE RM BATH LAUNDRY Project number Date Drawn by 6/18/2018 12:01:22 PMA2a CREEK LEVEL PLANSVAIL ROWHOUSES, VAILCOLORADOROW HOUSE 1106/18/2018 BRM No. Description Date 3 AMENDED DRB SUBMITTAL I 02 AUG 17 4 AMENDED DRB SUBMITTAL CORRECTION 25 AUG 17 5 AMENDED DRB SUBMITTAL II 28 NOV 17 6 AMENDED DRB SUBMITTAL III 30 APR 18 1/4" = 1'-0"1 EXISTING CREEK LEVEL PLAN 1/4" = 1'-0" 2 APPROVED CREEK LEVEL PLAN 1/4" = 1'-0"3 PROPOSED CREEK LEVEL PLAN DRB APPROVED 6/26/2018 12:00:00 AM 22'-7" REF W/D AIR 9 10 11 12 13 12 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 1 2 3 9 10 EDGE OF DECK UP DN T.O.FIN FLR 8178'-2 3/8" LEVEL TWO STREET T.O.FIN FLR 8179'-6 5/8" LEVEL TWO DN DN UP DN 3 1 A F C E 2 BEDROOM BATH BATH BEDROOM HALL CL CL ADDITION ENTRY A4b 3 A4a 3 2 A3 ADDITION TRASH EXTERIOR STAIR CREATED IN EASEMENT AGREEMENT (RN 201717959) B D A1 PWDR Project number Date Drawn by 6/18/2018 12:01:35 PMA2b STREET LEVEL PLANSVAIL ROWHOUSES, VAILCOLORADOROW HOUSE 1106/18/2018 BRM No. Description Date 3 AMENDED DRB SUBMITTAL I 02 AUG 17 4 AMENDED DRB SUBMITTAL CORRECTION 25 AUG 17 5 AMENDED DRB SUBMITTAL II 28 NOV 17 6 AMENDED DRB SUBMITTAL III 30 APR 18 1/4" = 1'-0" 1 EXISTING STREET LEVEL PLAN 1/4" = 1'-0"2 APPROVED STREET LEVEL PLAN 1/4" = 1'-0"3 PROPOSED STREET LEVEL PLAN DRB APPROVED 6/26/2018 12:00:00 AM 8"31_ 2" 21'-4" 31_ 2"8" 23'-01_ 8" DW TRASH REF STRUCTURAL SLAB FLOORWOOD FRAMED FLOOR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 23 456789 EDGE OF ENTRY ROOF BELOW EDGE OF DECK EDGE OF UPPER LEVEL T.O.FIN FLR 8188'-3 5/8" LEVEL THREE DN UP UP DN 3 1 A F C E 2 DINING KITCHEN LIVING TERRACE A4b 3 A4a 3 2 A3 ADDITION EXTERIOR STAIR CREATED IN EASEMENT AGREEMENT (RN 201717959) ADDITION B D A1 Project number Date Drawn by 4/30/2018 11:19:15 AMA2c SECOND LEVEL PLANSVAIL ROWHOUSES, VAILCOLORADO ROW HOUSE 11 04/30/2018 BRM No. Description Date 3 AMENDED DRB SUBMITTAL I 02 AUG 17 5 AMENDED DRB SUBMITTAL II 28 NOV 17 6 AMENDED DRB SUBMITTAL III 30 APR 18 1/4" = 1'-0"1 EXISTING SECOND LEVEL PLAN 1/4" = 1'-0"2 APPROVED SECOND LEVEL PLAN 1/4" = 1'-0"3 PROPOSED SECOND LEVEL PLAN DRB APPROVED 6/26/2018 12:00:00 AM REF AIR 123 456789101112 1314 T.O.FIN FLR 8197'-3 5/8" LEVEL FOUR DN RIDGE BEAM ABOVE DORMER ROOF FRAMING BELOWDN 3 1 A F C E 2 MECH BATH CL BEDROOM LIVING ROOM BELOW A4b 3 A4a 3 2 A3 ADDITION B D LAUNDRY A1 Project number Date Drawn by 4/30/2018 11:19:27 AMA2d THIRD LEVEL PLANSVAIL ROWHOUSES, VAILCOLORADO ROW HOUSE 11 04/30/2018 BRM No. Description Date 3 AMENDED DRB SUBMITTAL I 02 AUG 17 5 AMENDED DRB SUBMITTAL II 28 NOV 17 6 AMENDED DRB SUBMITTAL III 30 APR 18 1/4" = 1'-0" 1 EXISTING THIRD LEVEL PLAN 1/4" = 1'-0"2 APPROVED THIRD LEVEL PLAN 1/4" = 1'-0"3 PROPOSED THIRD LEVEL PLAN DRB APPROVED 6/26/2018 12:00:00 AM 3 1 A F C E 2 2 A3 4" / 12"4" / 12" RIDGE VALLEY 1/4" / 12" 1/4" / 12" VALLEY 1/4" / 12" 1/4" / 12" B D 1/4" / 12" 1/4" / 12"A1 1 - CREEK LEVEL 8,168' - 3 1/4" 2 - STREET LEVEL 8,178' - 1 3/4" 3 - SECOND LEVEL 8,188' - 3 5/8" 4 - THIRD LEVEL 8,198' - 3 1/8" AF C E BEDROOM DINING KITCHEN MECH BEDROOM HALLHALL 36" HIGH GUARD RAIL WITH 4" SPACE BETWEEN CROSS MEMBERS 36" HIGH GUARD RAIL WITH 4" SPACE BETWEEN CROSS MEMBERS 36" HIGH GUARD RAIL WITH 4" SPACE BETWEEN CROSS MEMBERS UNIT 10 BEYOND B D A1 LAUNDRY HALL PWDR SPARE RM SPA Project number Date Drawn by 6/18/2018 12:02:09 PMA3 BUILDING SECTION & ROOF PLANVAIL ROWHOUSES, VAILCOLORADOROW HOUSE 1106/18/2018 BRM No. Description Date 2 DRB SUBMITTAL 26 DEC 16 3 AMENDED DRB SUBMITTAL I 02 AUG 17 5 AMENDED DRB SUBMITTAL II 28 NOV 17 6 AMENDED DRB SUBMITTAL III 30 APR 18 1/4" = 1'-0"1 PROPOSED ROOF PLAN 1/4" = 1'-0"2 PROPOSED BUILDING SECTION DRB APPROVED 6/26/2018 12:00:00 AM 1 - CREEK LEVEL 8,168' - 3 1/4" 2 - STREET LEVEL 8,178' - 1 3/4" 3 - SECOND LEVEL 8,188' - 3 5/8" 4 - THIRD LEVEL 8,198' - 3 1/8" 3 1 2 2 A3 1 - CREEK LEVEL 8,168' - 3 1/4" 2 - STREET LEVEL 8,178' - 1 3/4" 3 - SECOND LEVEL 8,188' - 3 5/8" 4 - THIRD LEVEL 8,198' - 3 1/8" 3 12 2 A3 36" HIGH GUARD RAIL WITH 4" SPACE BETWEEN CROSS MEMBERS RETRACTABLE AWNING UTILITY CLOSET IN FOREGROUND Project number Date Drawn by 6/18/2018 12:02:38 PMA4 PROPOSED COLORSVAIL ROWHOUSES, VAILCOLORADOROW HOUSE 1106/18/2018 BRM No. Description Date 2 DRB SUBMITTAL 26 DEC 16 3 AMENDED DRB SUBMITTAL I 02 AUG 17 4 AMENDED DRB SUBMITTAL CORRECTION 25 AUG 17 5 AMENDED DRB SUBMITTAL II 28 NOV 17 6 AMENDED DRB SUBMITTAL III 30 APR 18 1/4" = 1'-0" 1 PROPOSED NORTH ELEVATION 1/4" = 1'-0" 2 PROPOSED SOUTH ELEVATION DRB APPROVED 6/26/2018 12:00:00 AM 1 - CREEK LEVEL 8,168' - 3 1/4" 2 - STREET LEVEL 8,178' - 1 3/4" 3 - SECOND LEVEL 8,188' - 3 5/8" 4 - THIRD LEVEL 8,198' - 3 1/8" 3 12 2 A3 36" HIGH GUARD RAIL WITH 4" SPACE BETWEEN CROSS MEMBERS TRASH / UTILITY ENCLOSURE TO BE HEIGHT OF EXISTING WALL. ENCLOSURE WILL NOT ROOF RETRACTABLE AWNING Project number Date Drawn by 4/30/2018 11:20:23 AMA4a SOUTH ELEVATION VAIL ROWHOUSES, VAILCOLORADO ROW HOUSE 1104/30/2018 BRM No. Description Date 3 AMENDED DRB SUBMITTAL I 02 AUG 17 4 AMENDED DRB SUBMITTAL CORRECTION 25 AUG 17 5 AMENDED DRB SUBMITTAL II 28 NOV 17 6 AMENDED DRB SUBMITTAL III 30 APR 18 1/4" = 1'-0"1 EXISTING SOUTH ELEVATION 1/4" = 1'-0"2 APPROVED SOUTH ELEVATION 1/4" = 1'-0"3 PROPOSED SOUTH ELEVATION DRB APPROVED 6/26/2018 12:00:00 AM 1 - CREEK LEVEL 8,168' - 3 1/4" 2 - STREET LEVEL 8,178' - 1 3/4" 3 - SECOND LEVEL 8,188' - 3 5/8" 4 - THIRD LEVEL 8,198' - 3 1/8" 31 2 2 A3 Project number Date Drawn by 4/30/2018 11:20:43 AMA4b NORTH ELEVATION VAIL ROWHOUSES, VAILCOLORADO ROW HOUSE 1104/30/2018 BRM No. Description Date 3 AMENDED DRB SUBMITTAL I 02 AUG 17 5 AMENDED DRB SUBMITTAL II 28 NOV 17 6 AMENDED DRB SUBMITTAL III 30 APR 18 1/4" = 1'-0"1 EXISTING NORTH ELEVATION 1/4" = 1'-0"2 APPROVED NORTH ELEVATION 1/4" = 1'-0"3 PROPOSED NORTH ELEVATION DRB APPROVED 6/26/2018 12:00:00 AM DRB APPROVED 6/26/2018 12:00:00 AM DRB APPROVED 6/26/2018 12:00:00 AM DRB APPROVED 6/26/2018 12:00:00 AM