Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A18-0037_approved documents_1531771587.pdf
75 South Frontage Road Fire-Construction Permit West, TOWN OF VAIL A18-0037 Vail,CO 81657 Issued: 07/16/2018 TOWN of VAIL0.ZOffice:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 4273 COLUMBINE DR(210112207011) (210112207011 ) Unit#: ParcelNumber: 210112207011 LegalDescription: Subdivision:BIGHORN 3RD ADDITION Block:9 Lot:16 Contacts ContactType:Applicant Full N ame:Brad Wolniak Address: 210 Edwards Village Blvd A108 Edwards,CO 81632 Phone: 9709268788 ContactType:PropertyOwner FullName:RS2 LLC Address: Phone: None Contractor Contractor Type:Alarm Company: SuperiorAlarm& Electronics, Inc State License#: Phone: 970-926-8788 Projectlnformation ProjectName:RS2 LLC Residence 2017 ProjectDescription: Install monitored fire alarm system in East side. Fees Paid Accounl#:001-0000.31111.00 Fire Alarm Permit Fee Fee Amount: $120.00 Accounl#:001-0000.31123.00 Fire Alarm ReviewFee Fee Amount: $288.00 TotalPaid: $408.00 Conditions Issued By:Town of Vail Fire and EmergencyServices Department NOTICE: By issuance of this Permitthe applicant agrees to complyto all Titles of the Townof Vail Code and all applicable State and Federal law.Failure to do so will void this Permit and the applicant shall forfeitall applicable fees. GE IntrusionSolutions Security Concord4 Overview Concord'4 is a full-featured security systemforresidential and Macro keyslavailable only on ATP 2100 and ATP 2600touchpads) commercialintrusion as well as residential fire detection that complies simplify system operation.Pressing a sing lebutton performs a system withfalsealarm standards.Easyto install and simpleto use,Concord's command,eliminating the need to enterin an entire command modular desig nand advanced software provide outstanding system string.Each of thefour macrobuttons on thesetouchpads can be flexibility to meetthe needs of virtually any residential or commercial programmed to perform one system command per partition.System security application. commands up to 14key presses can be programmed. Hig hstandards Macrokeyscan be used to create customarminglevels.For example, a user mig htcreate an arming level that would automatically bypass The panel comesstandardwith eig hthardwire zoneinputs,including selected interior sensors to create a special"Night"mode setting. a 2-wire smokedetectorloop that can handle up to 20 detectors.A built-in RF receiver with 96-zone capacity(600-1021-95R only)provides instant compatibilty with the completeline of GE Security Learn Mode Standard Features sensors.Two programmable outputs can be set up to activate external devicesduringan alarm or other system event. •Six partitions and eight built-in hardwire zones-96 zones maximum Easy expansion as either hardwire,wireless,or combination •96 wireless zones standard onboard)600-1021-95R only) ExpandConcord's capabilities by adding SuperBus®2000 8Z Input •Two onboard programmable outputs Modulesfor eig htadditional zones per module,or SuperBus 2000 •Compatible with all GE Security crystal and SAW Learn Mode sensors 4-Relay Output Modulesto add four moreoutput points.SnapCards" •SIA CP-01 FalseAlarm Reduction Standard compliant also add to system zoneinputsand outputs.Each cardlone per panel) •2-and 4-wire smokedetector compatibility connects easily to the panel circuit boardinside the cabinetfor a •Panel auxiliary power provides lamp clutter-free,professional installation.lncrease RF coverage area by •Built-in 12-watt siren driver adding up tofour SuperBus 2000 RF receivers or SuperBus 2000 RF transceivers.Each receiver supports all 96 zones. Expandthesystem evenfurtherwitha Phonelnterface/Voice Module Additional Features for on-and off-site system control using touch-tone phones.The •230 user-programmable access codes with programmable module includesa speaker output that provides on-site voicestatus authoritylevels and alarm messag es. •Latchkey numeric paging with optional keychaintouchpad activation Adding a SuperBus 2000 Energy Saver Module lets userscontrol •Audio verficationin partition 1 with VOX mode heating and air conditioning.The Power LineCarrier Power Transformer Irequireslnterrogator®200) adds X10lig htcontrol.The Wireless Gateway Module allows usersto •250-event history buffer viewablefrom any alphanumeric keypad, control and monitor the status of the systemfrom the Alarm.com Downloader,or automation device Web site. •Keyswitch arming using a hardwire or wireless zone Increase power capabilityfor system peripherals witha SuperBus 2000 •Programmable on site using alphanumerictouchpads or offsite 2-amp Power Supply Module with battery backup.The module provides using Enterprise 2 amps at 12VDC. •Timeand statusdisplayedon all touchpads •16 schedules availablefor scheduled lightingand outputs Effortless programming Conduct quick and easy on-site programming with alphanumeric touchpads and a menu-driven textinterface with shortcut menu numbers.A quick programming menu makesit even easierto install smaller,basic systems.For off-site programming,use Enterprise® downloader softwardversion 3.1 and later). Concord 4 Powerful, expandable security - with Learn Mode technology 71 '� A in go • GE Security North America Specifications T 888-GE-SECURITY p 888-437-3287 Power supply Outputs Required transformer Class il,16.5VAC,40VA,60Hz 12VDC,1.OA(max.combined Asia 12 VDC,4.5 Ah or 7 Ah re- OUT1/+12V(output 1) with auxiliarypower output) T 852-2907-8108Backup battery chargeable,sealed,lead-acid OUT2/OC)out ut 2) Open-collector,300 mA max F 852-214242-5063063 g P Battery backup time 24 hours(whenfullycharg ed, Regulated,current limited, Australia with appropriate externalload) Auxiliary power output self-resetting 12VDC:1.0A T 61-3-9239-1200 15 minutes under load every (max.combined withoutput 1) F 61-3-9239-1299 Battery test 24 hourslevery 4 hoursfor UL installations) Environmental Europe Transformer fuse Non-replaceable fuse 32 to 120°F(0 to 49°C);up T 32-2-725-11-20 Operating temperature to 140°F(60°C)under F 32-2-721-40-47 Panel auxiliary Current-limited,l.OA max. temporary conditions voltageoutput @12VDC -30 to 140°F(-34 to 60°C) Latin America Communication formats Storag etemperature T 305-593-4301 DTMF or pulsewithintegrated Relative humidity 90%max.,noncondensing F 305-593-4300 Dialing line seizure relay SIA Dig itall l(300 bpslor Physical www.gesecurity.com Formats supported ContactiD 14.0x12.Ox3.0in.(356x305 Dimensions(HxWxD) x76mm) Specifications subject to 3 central station phone change without notice. Capabilities numbers and 5pager Weight 5lb.,l0oz.(2.5kgI phone numbers Chassismaterial 0.048-in.11.2 mm)16g aug e ©2010 General Electric Company steel,punchedand formed All Rig hts Reserved Inputs Color Beige 96 max.hardwire or wireless; 8 hardwire zones builtin,96 Regulatory Inputzones zonewireless capacity built in FCCParts 15 and 68 (600-1021-95R only) UL 985,U L 1023,UL 1635 Databusformat SuperBus 2000with UL 1610600-1040 panel only), auto-enrolling capability cUL Databus capacity Up to l6devices SIA CP-01 2000 False Alarm Prevention Ordering Information Concord 4 panels Touchpad options 600-1021-95R Concord4 RF panel 60-597-95 HiTech handheld touchpad 600-1040 Concord 4 Commercial(does not include 96 zone 60-659-95R/60-832- Crystal,SAW and encrypted Learn More keychain wireless receiver) 95R/60-606-319.5 touchpad Expansion options 60-746-01/60-803-04 SuperBus 2000 2x16 and 2x20 LCD alphanumeric 60-620-01 SuperBus 2000 energ ysaver module(ESM) touchpads 60-756 Combo input/output SnapCard 60-804-04 SuperBus 2000 2x20 vacuum fluorescent display 60-757 8Z hardwireinput SnapCard alphanumeric touchpad 60-758 4-output SnapCard 60-820 SuperBus 2000 fixed display LCD touchpad 60-770 SuperBus 2000 4 output module 60-983 ATP1000 alphanumeric touchpad 60-774 SuperBus 2000 8Z input module 60-985/60-984 ATP2100 and ATP2600alphanumeric touchpads 60-783-02 SuperBus 2000 automation module 600-1020 FTP1000fixed eng lish touchpad 60-777-01 SuperBus 2000 phone interface and voice module Transformer options SuperBus 2000 commercial transceiver module 600-1023 16.5 V,40 VA standard transformer,UL listed for 60-821-95 (compatible with crystal sensors and touchpads) U.S.applications 600-1053 SuperBus 2000 GSM module 600-1023-CN 16.5 V,40 VA standard transformer,cUL/CSA listed 600-1019 SuperBus 2000 2.0 A power supply module for Canadian applications 600-1025-01-95R SuperBus 2000 transceiver module 600-1024 16.5 V,40 VA power line carrier transformer,UL listed for U.S.applications 0 1'6 imagination at work 910-3243 2010/01 160105) Concord ATP-1000 and FTP-1000 mom • i. Touchpads for use with Concord Systems i OVERVIEW Specifications Control Concord°panels with either the ATP-1000 AlphanumericCompatibility Concord 3,Concord Express, programmable touchpad or the FTP-1000 Fixed Eng lishtouchpad. Concord Ultra,Concord 4 Messages are displayed in a large and easy-to-see LCD window,and Electrical emergency keys are highlighted on the touchpad for safety. voltage 12VDC nominal Current 75mA(FTP-1000) Both the ATP-1000 and the FTP-1000 touchpads allow control of 60mA typical,110mA in alarm Concord Express,Concord 3,Concord Ultra,and Concord 4 products. Current (ATP 1000) The large display provides easy-to-read messages that indicate the Environmental Operating temperature 32 to 120°F(0 to 49°C) current status of the system.In addition,the ATP-1000 touchpad can be Storag etemperature -30 to 140°F(-34 t to 60°C) used forinstaller/user programming of the Concord control panels and Relative temperature 85%max.,nF sensing has the added capability of displaying customized zone naming text. Physical Both touchads includepolice,fire,and auxiliaryDimensions(LxWxD) 5 x 4.5x.75in.(127x 114 x 19 mm) p panic buttons that can be activated any time.A built-in speaker provides alarm,status,and Regulatory buttonpress sounds.The swing-down door reveals a label with basic UL(985,1023,1610) cUL(C1023-1974,S545-M89) system operating commands—or remove the door by simply op eningit For cULlisted applications,the unit shall be installed in accordance past its stop point.The door can be reattached laterif desired.Emergency with Part 1 of the Canadian Electrical Code. keys are highlighted on the keypad for safety and ease of use.All keys are backlit to insure error free operation—even in a dark room. Ordering Information STANDARD FEATURES 600-1020 Fixed Eng lishTouchpad • Large easy-to-read display 60-983 AlphanumericTouchpad • Improved backlighting of display and keys for better visibility •Stand-alone panic keys •Stand-alone arming keys •Traditional design to blend with any deco r • Easy to install interlogix North America ` United Technologies T 855-286-8889 Asia interlogix.Com T 852-2907-8108 Specifications subject to changewithout notice. Australia T 61-3-9239-1200 ©2013Interlog ix. All rig hts reserved. Europe Interlog ixis part of UTC Climate,Controls&Security, T 32-2-725-11-20 a unit of United Techno log iesCorporation. Latin America 302-3636 2013/06 (74066) T 561-998-6114 SYSTEM • �$ SENSOR`°' TM i4 Series Combination • CO/Photoelectric Smoke Detector (1 Best-in-class carbon monoxide(CO)and smoke detection technology in a single, system-connected device. Features Integration:The i4 Series combines CO and smoke detection • Single device for CO and smoke detection that uses less wiring into one device,requiring less wiring and fewer back boxesthan two separate devices.The i4 Series is compatible with i3(2WTA-B and fewer junction boxes or 4WTA-B),so an attractive CO monitoring solution can easily be • Compatible with a wide range of control panels with the use of the retrofitted into existing i3 installations.The i4 Series CO cell can be required i4 I nterfaceModule. easily replaced at end-of-life,resulting in a much lower life cost than • Sends distinct smoke and CO signals to the panel having to replace the entire detector. • Sounds Temporal 3 for smoke and Temporal 4 for CO Installation ease:The i4 Series Combination CO/Smoke detector • Built-in 85dB sounder requires less wiring than two separate CO and smoke devices. • LEDs disp lay both CO and smoke status Installers can pre-wire its p lug-in base,while its large wire-entry port and in-line terminals provide ample room for neatly routing wiring.The • External I R LED provides extended range sensitivity testing base accommodates several back boxoptions and also direct mounts • Versatile mounting allows for wall or ceiling placement using drywall anchors.The i4 head plugs into the basewith a simple • Easily replaceable electrochemical CO cell with 6-year end-of-life Stop-Drop'N LockTM action.When the detector's CO cell reaches end- timer that signals the panel and chirp sto alert the homeowner of-life,it can be easily replaced in the field without a tool. • RealTest®enables functional test using canned CO Intelligence:With the help of the module,the i4 Series transmits • Drift compensation and smoothing algorithms provide false distinct CO and smoke signals,allowing appropriate response alarm immunity from the central monitoring station.I ntelligentfeatures,such as drift • Compatible with SENS-RDR sensitivity tester compensation and smoothing algorithms,reduce nuisance alarms. • Full agency compliance with UL 268 and UL 2075 Instant inspection:The i4 Series LEDs enable instant inspection of detector status signaling normal/standby condition,alarm condition,maintenance/trouble condition or functional test mode. 2-wire devices allow loop testing via the EZ Walk feature where wiring can easily be verified by checking the LED status at each detector. Smoke sensitivity can be easily measured using the wireless SENS- RDR device.CO cell functionality can also be quickly validated in the field with canned CO per NFPA 720:2009 requirements using the Agency Listings detector's RealTest functionality. UL LISTED S268 1653:0227 i4 Series Combination CO/Smoke Detector Specifications Carbon monoxide(CO)/Smoke detector shall be a System Sensor model number COSMO-2W(2-Wire)/COSMO-4W(4-Wire)listed to UL 268 for Fire Protection Signaling Systems and to UL 2075 for Carbon Monoxide Gas Detection.The detector shall be photoelectric smoke sensing and electrochemical CO sensing and equipped with a sounder capable of Temp 3 and Temp 4 audible signals.The detector shall have nominal sensitivity of 2.5 percent per foot as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector's base shall be ableto mount to a single-gang electrical box or direct(surface mount)to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide LED indication that blinks to indicate normal standby,smoke alarm,smoke maintenance,CO alarm,CO trouble/end-of-life.When the detector is in CO trouble condition,it shall send a trouble signal to the panel.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry.The 2-wire model shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually.The detector shall have a replaceable CO cell that can be replaced at end of cell life. Electrical Specifications Operating Voltage(VDC): Nominal:12/24;Minimum:8.5;Maximum:35 Maximum Standby Current: 50 uA Maximum Alarm Current: 2-Wire 50mA;4-Wire 40mA Audible Signal: 85 dBA Maximum Reverse Polarity Current: 20 mA Maximum Start-up Current: 200uA Maximum Start-up Capacitance: .10 lJF Physical Specifications Dimension: Diameter:5.5 Depth:2.5"(includes base) Weight: 9.2 oz.(261 g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 20-95%RH StorageTemperature Range: -10—70°C(14—158°F) Sensitivity: 2.5%/ft nominal InputTerminals: 14 to 22 AWG Mounting: Back boxes:3.5"and 4"Octagonal;Single-gang;4"Square;2 x 4",3.5"and 4"round ceiling. Direct mount to wall or ceiling. Operation Modes/LED Status Green Red Blue Sounder Alarm Smoke: Off On Off Temp 3 Alarm CO: Off Off On Temp 4 Alarm Smoke&CO: Off On On Temp 3 Power Up: Blink 5 sec. Blink 5 sec Blink 5 sec. Off Standby: Blink 5 sec. Off Off Off RealTest®Mode(CO): Off Off Blink 1 sec. Off After CO is Sprayed: Off Off On Temp 4 Smoke Maintenance: Off Blink 5 sec. Off Off CO Trouble: Off Off Blinks sec. Off End-of-Life: Off Off Blink 5 sec. I ntermittent i4 Series Interface and Reversing Relay Module The i4 Interface Module connects u p to 12 detectors to a wide range o fcontrol panels using only 2 to 3 zones. I t also interconnects the devices, so when one device alarms, they all sound. Features Integration:The i4 module allows up to 12 i4 Series or compatible • Easily integrates up to 12 compatible detectors to a wide range of i3 Series smoke detector models to be integrated into a fire alarm panel using only 2 to 3 zones:a smoke zone,a CO zone and an control panels optional trouble zone. Detectors sound Temp 3 for smoke and Temp • 2-wire module is compatible with COSMO-2W combination 4 for CO events.The i4 module can be used to alarm all sounders in detectors and 2WTA-B smoke detectors. compatible detectors for smoke and CO events.When one detector • 4-wire module is compatible with COSMO-4W combination detects smoke or CO and goes into alarm,all connected detectors detectors and 4VVTA-B smoke detectors. alarm,offering the highest level of warning to the homeowner. • Sends distinct smoke and CO signals from i4 detectors to the panel Installation ease:The i4 Series I nterfaceModule mounts to a • LED indication shows when a detector on the loop requires 411/16-inch square back box for quick and easy installation.Terminal cleaning or maintenance(2-wire detectors only) b locks with durable SEMS screws ensure a reliable connection.I t • I nitiatesthe EZ Walk loop test(2-wire detectors only) also has pre-drilled holes for easy mounting inside a metal enclosure • Module interconnects the sounders of all devices connected to it. Intelligence:The i4 Interface Module allows i4 and compatible i3 No RSS-MOD is required.Optional trigger inputs are provided to sound multiple modules. smoke detector models(2WTA-B and 4WTA-B)to communicate with any listed fire alarm control panel capable of utilizing this module. Instant inspection:The i4 Interface Module provides LED status indication for the loop,displaying normal operation,loop wiring fault, smoke events,smoke maintenance(2-wire only),CO events,and CO maintenance/end-of-life. Agency Listings Tlfs UL LISTED S91, 1653:0228 i4 Series Interface Module Specifications The i4 module shall be a System Sensor i4 Series model number COSMOD2W(2-wire)or COSMOD4W(4-wire)listed to UL 864 and UL 985 for Control Units for Fire Protection Signaling Systems.The module shall include provisions for mounting to 4-inch square back box. Wiring connections shall be made by means of SEMS screws.The module shall provide4 LED indicators that blink or illuminate to indicate communication status,maintenance alert,alarm or freeze trouble conditions,and EZ Walk loop test mode(2-wire module only).The module shall allow communication to i4 Series and i3 Series detectors with sounders with any UL 864-and UL 985-listed fire alarm control panel capable of utilizing this module.The 2-wire module shall offer provisions for Style D/Class A wiring on I DC loops and shall providea loop testing capability(EZ Walk)to verify the initiating loop wiring. Electrical Specifications Module Operating Voltage(VDC): Nom.: 12/24;Min.:8.5(2-wire),10(4-wire,power limited);Max.:35 VDC(power limited) Standby Current: 2-Wire:61mA(max.),45mA(12V I n),26mA(24V I n); 4-Wire:52mA'(max.),37mA'(12V I n),22mA'(24V I n) Alarm Current2: 2-Wire: 181mA(max.),121mA(12V I n),64mA(24V I n); 4-Wire:78mA'(max.),57mA1(12V I n),34mA'(24V I n) Maximum Ripple Voltage: 30%of applied p ower Maximum AlarmThreshold: 9.2 Volts DC Alarm and Maintenance Contact Rating: 100 mA @ 36 Volts DC,resistive,25 ohms Maximum Loop Wiring Resistance: 2-Wire 50 Ohms;4-Wire 300 Ohms Trigger inputs: Min On Voltage:1.5V;Max.:Vin 'Does not include current draw from attached detectorsor EOL relay.2 Does not include reverse polarity current draw from attached detectors. Physical Specifications Module Dimension: Height:6.04 Width:6.04";Depth:1.00" Weight: 9.6 oz.272(g) Operating Temperature Range: 0—50°C(32—122°F) Operating Humidity Range: 5-95%RH StorageTemperature Range: -20—70°C(-4—158°F) InputTerminals: 14 to 22 AWG Mounting: 411/16"square back box or inside a metal enclosure Operation Modes/LED Status Green Yellow Red Blue Alarm Smoke: Blink 1 sec. Off On Off Alarm CO: Blink 1 sec. Off Off On Alarm Smoke&CO: Blink 1 sec. Off On On No power/No communication: Off Off Off Off Loop wiring fault: Blink 1 sec. On Off Off EZ WalkTestMode(2-wire only): Blink 1 sec. Blink 5 sec. Off Off SmokeMaintenance(2-wire only): Blink 1 sec. Off Blink 5 sec. Off Smoke FreezeTrouble(P 2WTA-B only): Blink 1 sec. Off Blink 10 sec. Off CO Trouble: Blink 1 sec. Off Off Blink 5 sec. Module Power-Up Sequence/LED Status Condition Duration Maintenance/Freeze trouble LED indication 6 minutes EZ Walk test available 6 minutes after power up or panel reset Ordering Information Part No. Description COSMO-2W 12/24 volt,2-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMO-4W 12/24 volt,4-wire,system-connected,combination carbon monoxide/smoke detector with RealTest technology COSMOD2W 2-wire interface module(required to use with COSMO-2W models) COSMOD4W 4-wire interface module(required to use with COSMO-4W models) CO-REPL Replacement CO cell for COSMO-2W and COSMO-4W models SENS-RDR Sensitivity reader EOLR-1 End-of-line relay(required with 4-wiresystems) *--Th SYSTEM 3825 Ohio Avenue•St.Charles,I L 60174 ©2013 System Sensor. Phone:800-SENSOR2•Fsor.co 630-377-6495 Product specifications subject to change without notice.Visitsystemsensor.com SENSOR® for current product information,including the latestversion of this data sheet. www.systemsensor.com com coDs3o3o2•11/13 SYSTEM �$ SENSOR' • SmokeDetectors with 4 1 Sounder and RelayOption 1111 System Sensorir sounder and relay smokedetectors apply the guiding principles of installation ease, - 3 intelligence,and instantinspection in a series of TAA specialty conventional devices. Features Installation ease.Throughoutthe i3 series,installation is simple 85 dB sounder with its installer-friendly base and p lug-indesign.The base • accommodates a broad range of back box and direct mounting •Form C relay op tionsand p rovidesamp le sp acefor pre-wiring the device.To •Isolated thermal sensor comp letethe installation,the i3 detector p lugs into its base with a simp leStop-Drop'N Lockaction. •Plug-in design (base included) Intelligence.To reduce the likelihood of nuisance alarms,all •In-line terminals i detectors are equip p edwith both driftcomp ensationand •Flexible mounting options smoothing algorithms.These cap abilitiesminimize both short-and Stop-Drop'N Lock'attachment to the base long-term causes of nuisance alarms,such as RF interference and • dust accumulation.When connected to the 2W-MOD2 loop test/ •Removable cover and chamber maintenance module or an i3 Ready'panel 2-wire i3 detectors can generate a remote maintenance signal when in a maintenance or •Remote maintenance signaling freeze trouble condition.To measure the sensitivity of any i3 detector, •Drift comp ensationand smoothing algorithms the SENS-RDR disp laysthe reading,in terms of percent-per-foot •Simp lifted sensitivity measurement obscuration within seconds. •Dual-color LEDs Instant ins pection.i3 has red and green LEDsto simplify local status indication during power-up,standby,alarm,maintenance, and freeze trouble conditions.When in alarm,i3 sounder models generate an 85 dB temp oraltone.If connected to the RRS-MOD reversing relay/synchronization module,all i3 sounders on the loop will activate when one detector is in alarm.The RRS-MOD also synchronizes i3 sounder outp utto ensure a clear audible signal. Agency Listings Should the applicationcall for differentiating betweena local and a general alarm,the i3 line offers an isolated thermal model,which c MEA MSFM EI initiates a local alarm when smoke is detected,and a general alarm LISTED APPROVED I approved approved cC•'� ® us when the thermal sensor is activated. 5911 3015195 7272-1653:164 372-02-E 2133 3180932 Cb Smoke Detector Specifications Electrical Specifications LED Modes OperatingVoltage Nominal:12/24V non-polarized LED Mode Green LED Red LED Condition Duration 2-wire:8.5Vto35V Power up Blink every Blinkeveryl0 Initial LED 80 seconds 4-wire:10 V to 35 V 10 seconds seconds status Maximum RippleVoltage 30%of app liedvoltage(peak top eal4 indication Standby Current 2-wire:50 pA maximum average Normal Blink every5 off 4-wire:50 pA maximum average (standby) seconds Peak Standby Current 2-wire:100 pA Out of off Blink every5 4-wire:n/a sensitivity seconds Maximum Alarm Current 2-wire:2WTR-B:130 mA limited by control Freeze off Blink every 10 panel trouble seconds 2WTA-B:130 mA** Alarm off Solid 4-wire:4VVTAB,4WTR B:35 mA Power-Up Sequencefor LED Indication 4WTAR-B,4WITAR-B:50 mA **Direct Power(Non-Reverse Polarity):130 Condition Duration mA limited by p anel.Reverse Polarity Power: Initial LED 80 seconds 30 mA for the 2WTA-Bin alarm;12 mA for all status other 2WTA-B units on the loop.Add 25 mA indication for the RRS-MODreversing relay alarm current. Architect/Engineer Specifications Alarm Contact Ratings 2-wire:n/a Smokedetector shall be a System Sensor i3 Series model number , 4-wire:0.5 A @ 30 V AC/DC listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Form C Contact Ratings 2 A @ 30 V AC/DC Systems.The detector shall be a combination photoelectric/thermal Physical Specifications equip p ed✓vith a sounder(model 2WTA-B,4WTA-B),a FormC relay(model 2WTR-B),a combination sounder/relay(model 4WTAR-B),or an isolated OperatingTemperature 32°F to 100°F(0°C to 37.8°C) thermal/sounder/relay(model 4WITAR-B).The detector shall include a Range mounting base for mounting to 31/-inch and 4-inch octagonal,single-gang, Operating H umidity 0 to 95%RH non-condensing and 4-inch square back boxeswith a p lasterring,or direct mount to the Range ceiling using drywall anchors.Wiringconnectionsshall be made by means Thermal Sensor 135°F(57.2°C)fixed of SEMS screws.Thedetector shall allow pre-wiring of the base and the FreezeTrouble 41°F(5°C) head shall be a p lug-intyp eThe detector shall have a nominal sensitivity Sensitivity 2.5%/ft.nominal of 2.5 percent p erfoot as measured in the UL smoke box.The detector shall be cap ableof automatically adjusting its sensitivity by means of drift InputTerminals 14-22 AWG compensation and smoothing algorithms.The detector shall provide dual- Dimensions(including 5.3 inches(134 mm)diameter,2.0 inches color LEDindication that blinks to indicate power-up,normal standby,out of base) (51 mm)height sensitivity,alarm,and freeze trouble conditions.When used in conjunction ApproximateWeight 7.1 oz(200g) with the 2W-MOD2 module,2-wire models shall include a maintenance Sound Pressure Output 85 dBA(models 2WTA-B,4WTA-B,4WTAR-B, signal to indicate the need for maintenance at the alarm control p aneland and 4WITAR-B only) shall provide a loop testing cap abilityto verify the circuit withouttesting each Mounting 31/2 inch octagonal back box 4-inch octagonal detectorindividually.When used in conjunction with the RRS-MOD module, back box,single gang back box 4-inch square all i3 sounder models on a loop shall sound when one sounder alarms,all shall back box with a p lasterring direct mount be synchronized,and all sounders may be silenced from the panel. ceiling Ordering Information Model Thermal Wiring Alarm Current Model Description 2WTA-B Yes 2-wire 130 mA max.limited by RRS-MOD Reversing relay/synchronization module controlpanel 2W-MOD2 2-wire loop test/maintenance module 2WTR-B Yes 2-wire 130 mA max.limited by SENS-RDR Sensitivity reader control panel RT Removal/replacement tool 4WTA-B Yes 4-wire 35 mA A77-AB2 Retrofit adapterbracket 4WTR-B Yes 4-wire 35 mA 4WTAR-B Yes 4-wire 50 mA 4WITAR-B Yes 4-wire 50 mA *--Th SYSTEM ©2009 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subjectto change Wthout notice.Vsit systemsensoccom for ��)' SENSOR® Phone:800-SENSOR2•Fax:630-377-6495 current p roductnformation,including the latest version of this data sheet. A05-0348-004.6/09.#2170 12/24VDC r n Monoxide Cabo DetectorwithSafeTestTN 0 260-CO "Th 417 e o c1" flc\ G Overview Standard Features The SafeAirTM 260-CO carbon monoxide(CO)detector is an accu- • 10-yearend-of-lifesignal rate and reliable means of alerting building occupants of potentially SafeTest"feature — functional test with spray of real CO gas dangerous levels of CO in the protected area.The internal electro- chemical sensor communicates with a sophisticated on-board • Advanced electro-chemical sensing technology microprocessor that accurately tracks CO levels over time. • Wiring option activates sounders of all connected detectors This commercial-grade detection technology results in quick when any one of them goes into alarm response,reliable sensing,fast reset time,and superior false alarm • Deep housing with plenty of room for wiring immunity.Its small size allows the 260-CO to blend inconspicu- ously with any decor,and its smooth contoured design is co mpat- • UL 2075 compliant ib le with both residential and commercial environments. • Transmits sensorend-of-lifeto the supervising panel and cen- Unaffected by normal indoor temperature variations,the 260-CO tral station if the system is monitored automatically adjusts for environmental changes and operates • CO sensitivity conforms to UL 2034 requirements reliably under a wide variety of conditions.It also monitors its own •performance and compensates for sensitivity drift throughout the Built in trouble/power supervision relay course of its service life. • Self-diagnosticskeep the device operating optimally through- The 260-CO features the SafeTestTM functional test feature,which out its service life facilitates testing with real CO gas.SafeTest meets the functional • 12 or 24VDC operation and 150mA Form C relay test requirement in NFPA 720,2009/2012 editions. • Large SEMS terminals ease wiring installation 14 to 22 AWG Like all CO detectors,the 260-CO has a limited service life.But • One-touch TEST/HUSH button simplifies local operation unlike most,which last only six years,the 260-CO'sadvanced sensor features a service life rated at 10 years.When it approach- • Integrated 85 dBa temporal-4so under for local notification es this point,the 260-CO'send-of-lifetimer automatically triggers • On-board LED provides local alarm and trouble indication a warning that indicates the device must be serviced.This warning annunciates at the detector, as well as at the control panel,and • Inconspicuous footprint and attractively contoured design optionally at a remote monitoring station. • Adapter plate simplifies replacing ESL 240-CO edetectors An integrated temporal-4 sounder provides local signaling capability for the 260-CO,and it easily interfaces with any intrusion or fire alarm system by means of its output relay.Its low current draw results in little additional demand on the system power supply. Pagel of 4 DATA SHEET ESL85001-0632 interlogix.com Not to be used for installation purposes. Issues Application ✓ Centrally located on every habitable level of the building and in every HVACzone based on an engineering evaluation con- The SafeAir 260-CO Carbon Monoxide Detector is intended for sidering potential sources and migration of carbon monoxide ordinary indoor-dwelling unit applications in both residential and commercial occupancies, including single/multiple family residential 1( On the ceiling in the same room as permanently installed fuel occupancies,hotel rooms,dorm rooms,and other areas approved burning appliances by the authority having jurisdiction(AHJ).The 260-COdetector ✓ In any area required by local building codes,legislation,or the can connect to either UL 985(Household Fire Warning)or UL 864 authority having jurisdiction (Commercial Fire)control panels.It is not intended for use in indus- 1/ On a firm, permanent surface trial applications such as gasoline refineries or parking garages, which require different listings. Do not install the CO detector: The 260-COis a four-wire device that uses a Class 2 output from X Within 5 ft.(1.5 m)of any cooking appliance a control panel.Nonetheless,the primary alarm notification de- X Within 10 ft.(3 m)of a fuel-burningappliance vice remains the 260-CO's internal sounder with the control panel X Near air conditioners,heating registers,and any other ventilation secondary to these purposes.The 260-COis not a substitute fo rlife source that may interfere with CO gas entering the detector safety devices,and should be only considered as an integral part of a comprehensive safety program. X Where furniture or draperies may obstruct the airflow X In a recessed area Selecting a suitable location is critical to the correct operation of CO detectors.Install the 260-CO in accordance with NFPA 720 Standard for the Installation of Carbon Monoxide(CO)Detection and Warning Equipment. Place wall-mounteddetectors at least Operation 5 ft.(1.5 m) up fromthe floor.For ceiling mounted applications, SafeTest functional test:This test facilitates the use of CO test place the detector at least 1 ft.(0.3 m)from any wall. spray to verify the correct operation of the detector,which is man- Recommended CO detector locations: datory per NFPA 720.The SafeTest mode is activated by pressing ✓ Within 10 ft.(3 m)of all sleeping areas,including areas such and holding the test/hush button for 510 seconds.While in Saf as hotel rooms and dorm rooms. eTest mode,directing UL-classifiedCO testing spray at the sensor port will result in the activation of the alarm relay,and the sounder ✓ In a suitable environment:areas with a temperature range and red LED in a temporal-four pattern.Pressing and holding the of 40 to 100 °F(4.4 to 37.8°C)and with a relative humidity test/hush will exit SafeTest mode. range of 10 to 90%noncondensing. ✓ In residential dwellings,locate detectors in every bedroom Distinct temporal-four sounder alarm:The 85 dB temporal- and on each level.At a minimum, place one detector outside four sounder provides a distinctive alarm notification that is easy the sleeping areas. to differentiate from smoke alarm notification devices.The alarm beeps four times, rests five seconds and then repeats the pattern. Test/hush button:Use the test/hush button to test the alarm and silence an activated alarm.Pushing the test/hush button silences _ the integral sounder for five minutes.The red alarm light stays on • ! I O and if CO is still present after five minutes,the detector once again r� I sounds in the temporal four pattern. p " End of sensor life indicator:The detector uses both a flashing ���� ! TO green LED and intermittent sounder chirps to indicate that the de- tector needs replacing.To silence the detector, push the test/hush O button.The detector also begins signaling a trouble when the CO 1! r�l_ sensoris approaching end-of-life. Common trouble relay:The trouble relay opens to indicate a trouble condition upon lost power,CO sensor cell trouble,or cell 0 Recommended locations for CO detectors end-of-Iife.When connected to a listed control panel,the trouble Always check with your local building codes, relay can report a trouble condition locally at the panel and option- legislation,and Authority Having Jurisdiction ally at the central station,if the system is monitored. for specific CO location requirements in your area Recommended CO detectorlocations in commercial occupancies: WAR NINGS:Connect the CO detector only to a zone dedicat ed exclusively for CO detection and that is monitored 24 hours ✓ Outside each separate sleeping area in the immediate vicinity a day.Do not connect to an initiating circuit with fire or security of the bedrooms(including areas such as hotel rooms and devices.Failure to properly install,test,and maintain a CO dorm rooms) detector may cause it to fail,potentially resulting in loss of life. ✓ On every occupied level of a dwelling unit, including base- ments,but excluding attics and crawl spaces Page 2 of 4 DATA SHEET ESL85 001-0632 Not to be used for installation purposes. Issue 1 Installation The 260-CO/240-COe adapter p late [•7 The 260-CO Carbon Monoxide Detector is a four-wire device Use a 250-COPLT adaptor designed to use a Class 2 outputfroma control panel or auxiliary plate when replacing a 24011 - power supply Listed to UL 985 or 864 standards. COewith a 260 Coto cover All wiring must conform to the NFPA 70 National Electric Code,UL any paint discoloration left 2075, NFPA 720, and applicable codes.Use 14 to 22 AWG wire. behind. 1- • Wiring Single device, Multip le devices, Multip ledevices, single zone single zone separate alarm,trouble zone EOL device EOL device EOL device �L�c - c - c `��ii - NC - NC II\�I ��� Il[o�71 NIC 0] NC 0 CEN moi.01 I0 NO 0 NO Alarm + - `v c l'0, c IDC Power `�* Nc l 0] NC -1A. -1. Tandem Interconnect: Use a Single Circuit Reversal Module when wiring multiple 260-CO detectors for tandem geoNC NC irE. interconnect.On alarm,the NO NO module disconnects the detec- tor from its normal power supply and applies reverse polarity from f.* Nce g* Nc the notification appliance circuit. +l``- EOL device +IICO�! EOL device pp -Iy�' -11W1 This causes the sounders to I I activate on other 260-00 detec- ® N 0 ® e m m e tors that are on the same loop. s . e e z . e e Only the initiatingdetector will ESL 405 ESL 405 y Polarity Reversal Polarity Reversal sound and blink red.All others Module Module in tandem mode will sound but NC , e 5 , I,•; NC , s 5 , not blink red. B ® ® ® I`�� ® ® ® ® NOi_�� NO ® i ? ® ® ® (§, ® i I ? ® ® ® AlarmControl Panel Power NAC Alarm SUPV Power NAG IDC IDC IDC Control Panel Page3of4 DATA SHEET ESL85001-0632 Not to be used for installation purposes. Issue 1 Specifications Input voltage 12 or 24 VDC supplied by UL 985 or UL 864 listed control panel or resettable auxiliary power supply Current consumption Normal 20 mA Alarm 40 mA(75 mA in test) Alarm relay 150 mA at 33 VDC Type Form C UL rating Zone Common trouble relay 150 mA at 33 VDC Type Normally opened held closed with power applied UL rating Common Sensor life 10 years from date of manufacture Sounder 85 dB Compatible control panel Listed to UL 985 or 864 standards Compatible electrical box 2-1/2 in.(64 mm)single-gang Wire size 14 to 22 AWG(0.25 to 2.0 mm2) Dimensions(W x L x D) Detector 3.1 x 4.6 x 1.4 in.(7.8 x 11.7 x 3.6 cm) Adapter plate 4.5 x 6.5 x 0.2 in.(11.4 x 16.5 x 0.5 cm) Color White Operating environment Temperature 40 to 100 °F(4.4 to 37.8°C) Relative humidity 10 to 90%noncondensing CO sensitivity 70 ppm,60 to 240 minutes 150 ppm,10 to 50 minutes 400 ppm,4 to 15 minutes North America T 885-286-8889 Asia T852-2907-8108 Ordering Information F 852-2142-5063 Model Descrip tion Australia 260-CO SafeAir Carbon monoxide detector,alarm&trouble relays, T 61-3-9239-1200 sounder,end-of life signal, 12/24VDC F 61-3-9239-1299 250-COPLT-5PKG Adaptor plate for use when replacing the 240-COeCO detector with a 260-CO Europe ESL 405-01 Polarity Reversal Module,24 VDC T32-2-725-11-2o ESL405-03 Polarity Reversal Module,12 VDC F 32-2-721-40-47 ESL 405-05 Polarity Reversal Module,12/24VDC Latin America CO Gas Test Spray Functional CO gas test spray Solo C-6 from SDI T 561-998-6114 (www.sdifire.com)available thro ugh security distribution. F 561-994-6572 interlogix interlogix.com Specifications subject to change without notice. ©2012 Interlogix. Interlogix is part of UTC Climate Controls&Security, a unit of United Technologies Corporation. All rights reserved Page 4 of 4 DATA SHEET ESL85 001-0632 7 Not to be used for installation purposes. Issue 1 SYSTEM �$ SENSOR`°' Mini-Horns = = Ji. The SpectrAlert®Advance series of mini-horn sounders are � w designed to simplify installations to provide primary and secondary signaling for fire and security applications. Et) SPECTRAlert difiemmyA N Features The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel,motel or residential fire system applications,where a • 12 and 24V operation smaller notification device is desired.The mini-horns offer high and • High and low volume settings low volume settings,and temporal or non-temporal tones. The horns • Temporal and non-temporal tones can be mounted to single gang back box esfor aesthetically sensitive • Mounts to single gang back box applications. Synchronization is also provided when using the MDL module. • Compatible with MDL sync module • Mechanically and electrically compatible with PA400series The MHR and MHW mini-horns can operate between32 and 120 Mini-AlertTM sounders degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply.They are listed to Underwriter's Laboratories • Listing for ceiling or wall mounting Standard UL 464 for fire protective signaling systems. Agency Listings U` ti Nc „,„„‘,E LISTED APP® S4011 3028007 CS1099 7135-1653:196 SpectrAlert®Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box.Mini-horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems.Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.When used with the Sync•Circuit'"'Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.61 x 2.9"W x .45"D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F(0°C to 49°C) Mounting Surface:deep single-gang back box(23/4"deep) Flush:Standard 4"x 4"back box with single gang mud ring,which allows sufficient clearance for conduit entrance. Electrical Specifications InputTerminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data Sounder Output(dBA) Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 Nominal 12 16-33 16-33 VDC VFWR VDC VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- High 72 71 75 74 80 79 temporal 4 Non- Low 70 69 73 72 78 77 temporal Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information Part No. Description MHR Mini-Horn,Red MHW Mini-Horn,White *� SYSTEM ©2012 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensorcom �� I SENSOR® Phone:800-SENSOR 2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS01500.3/12