HomeMy WebLinkAboutB15-0131_E3_1436284680.pdfFixture
Type
Lamp Type Quantity Fixture
Type
Lamp Type Quantity
C INCANDESCENT 2 A LED 10
D INCANDESCENT 3 A2 LED 3
E INCANDESCENT 1 A3 LED 4
H LED 1 B LED 2
B2 LED 2
F LED 4
G LED 2
Incandescent Total: 7 High-Efficacy Total: 27
Percent High-Efficacy: 79.41% (must be minimum of 50%)
Incandescent Fixtures High Efficacy Fixtures
IECC 2009 CALCULATION
TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER MOUNTING NO LAMP VOLTS DIMENSIONS REMARKS
A RECESSED DOWNLIGHT INDY L4-17-27-1 RECESSED 1 23.1 W LED 120
L400-HW-C-Q
A2 ADJUSTABLE RECESSED DOWNLIGHT INDY LA4-17-27-1 RECESSED 1 23.1 W LED 120
LA400-N-C
B CLOSET LIGHT 4' LED LITHONIA WL4-20L- -LP830 SURFACE 1 18.9 W LED 120
B2 CLOSET LIGHT 2' LED LITHONIA WL2-08L- -LP830 SURFACE 1 7.5W LED 120
C CEILING FAN COORD W/ OWNER COORD W/ OWNER SUSPENDED 4 60W INC 120 COORD WITH OWNER
D BATHROOM VANITY COORD W/ OWNER COORD W/ OWNER SURFACE 4 60W INC 120 COORD WITH OWNER
E CHANDELIER COORD W/ OWNER COORD W/ OWNER SURFACE 12 60W INC 120 COORD WITH OWNER
CHROMA I
F TRACK LIGHTING BRUCK 137-317-MC-4-M SURFACE 1 8.5 W LED 120
REUSE EXISTING FIXTURES
G UNDERCABINET LED STRIP GM LIGHTING LTR300-100-27 SURFACE 1 3W/FT 120 PROVIDE NEW FIXTURE IF FIELD
LED-CHL CONDITIONS REQUIRE
H CLOSE TO CEILING FIXTURE COORD W/ OWNER COORD W/ OWNER SURFACE 4 100W INC 120 COORD WITH OWNER
NOTE: ALTERNATE EQUIVALENT LIGHTING PACKAGES ACCEPTED WITH ENGINEER'S REVIEW OF SUBMITTAL.
THE ELECTRICAL CONTRACTOR SHALL PROVIDE FIRE TENTING TO MAINTAIN FIRE RATINGS FOR ALL RECESSED FIXTURES LOCATED IN FIRE RATED ASSEMBLIES.
BACKBOXES FOR NON-IC RATED FIXTURES MUST HAVE 3" CLEARANCE BETWEEN FIXTURE HOUSING AND INSIDE SURFACES OF BACKBOXES. BACK BOXES FOR IC-RATED FIXTURES MAY BE TIGHT TO FIXTURE HOUSING.
LUMINAIRE SCHEDULE
07/07/15