Loading...
HomeMy WebLinkAboutApproved Plans_28.pdfE.'l. \!ii\\).\(.,- --e:. -v~\ \ ,. I I I I I t ( I I I l I ( I I I ( I I I I I J I I I I t I I I I ( I : :--, : : ~ I I I ~ ~ I I \~.. "J. Ii-i I ,. p. I 1 J I I <:.) 3 ( J ~ u.. I I -z r ' I I r ~ I - t t ~ I I )' I ~ 0 .. . , -- - I I : ! ___ ---~.; ------Ii\ I f I I I I 1 l I I I I I I I I I I I I I I : I Job Name: Location: Engineer: Wholesaler: Contractor: NOTES: 0 KHI055 8.3 55 0 KHN085 85 85 0 KHNllO 11 110 J/::-4 KHN155 155 155 <t KHN199 19.9 199.9 ~ KHl285 285 285 Notes: ® HIGH EFFICIENCY BOILERS & WATER HEATERS Submittal Sheet FLUE 95 51 44 6" 95 79 69 6" 95 102 89 7-3/8" 95 144 125 7-3/8" 95 185 161 7-1/2" 95 264 229 7-1/2" KNIGHT FIRE TUBE BOILER D D E 8-3/8" 11-1/8" 10-1/2" 8-3/8" 11-1/8" 10-1/2" 9-3/4" 11-1/8" 10-5/8" 9-3/4" 11-1/8" 10-5/8" 10-1/2" 11-1/8" 11-5/8" 10-1/2" 11-1/8" 11-5/8" Model No. Type Gas: Equipment Tag(s): AIR INLET WATER OUTLET GAS CON NE CTI ON HIGH-VOLTAGE ELECTRICAL CONNECTIONS LOW-VOLTAGE ELECTRICAL CONNECTIONS G H WATER INLET CONDENSATE DRAIN 13-1/4" 37-1/2" 32-5/8" 32-1/4" 13-1/4" 37-1/2" 32-5/8" 32-1/4" 14-5/8" 37-3/4" 33' 32-1/2" 14-5/8" 37-3/4" 33' 32-1/2" 15-3/8" 38" 33" 32-3/4" 15-3/8" 38" 33" 32-3/4" 13-1/4" 3-3/8" 13-1/4" 3-3/8" 14" 4-5/8" 14" 4-5/8" 14" 4-5/8" 14" 4-5/8" 43-3/8" 1/4" -1-1/4" ADJUSTABLE 1/2" 1" T T 160 1/2" 1" T T 165 1/2" 1" 3" 3" 170 1/2" 1· 3" 3" 175 1/2" 1-1/4" 3" 3" 195 1/2" 1-1/4" 3" 3" 205 • Indoor installation only. All information subject to change. Change "N• to "L• for • Lochinvar should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, LP gas models. extensive piping systems, etc. .~ • The Net AHR/ Water Ratings shown are based on a piping and pickup allowance of 1.15. • The ratings have been determined under the provisions governing forced draft burners. FIRING (ODES M9 Standard Construction Ml California Code Smart System TM Features >Smart System Digital Operating Control Multi-Color Graphic LCD Display w /Navigation Dial, Soft Keys and Loch-N-Link™ USB programming >Three Boller Setpolnt Temperature Inputs Plus Domestic Hot Water Prioritization >Built-in Cascading Sequencer for up to 8 Boilers, with Cascade Redundancy Multiple Size Boiler Cascade Lead Lag Efficiency Optimization Front End Loading Capability >Outdoor Reset Control with Outdoor Air Sensor Programmable for Three Reset Temperature Inputs >Programmable System Efficiency Optimizers SH Night Setback DHW Night Setback Anti-Cycling Outdoor Air Reset Curve Ramp Delay Modulation Factor Control Boost Temperature & Time >Four Pump Control System Pump with Parameter for Continuous Operation Boiler Pump with Variable Speed Control Domestic Hot Water Pu mp Domestic Hot Water Recirculation >Domestic Hot Water Prioritization DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps controlled by the SMART SYSTEM DHW Modulation Limiting Separately Adjustable Space Heat/DHW Switching Times >Building Management System Integration 0-10 VDC Input to Control Modulation or Setpoint 0-10 VDC Modulation Rate Output 0-10 VDC Input to Enable/Disable Call for Heat >Access to BMS Settings through Graphic LCD Display >High-Voltage Terminal Strip 120 VAC I 60 Hertz I 1 Phase Power Supply Three Sets of Pump Contacts >Low-Voltage Terminal Strip DHW Recirculation Pump Start/Stop 24 VAC Device Relay Proving Switch Contacts Flow Switch Contacts Alarm on Any Failure Contacts Runtime Contacts DHW Thermostat Contacts 3 Space Heat Thermostat Contacts System Sensor Contacts DHW Tank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts 0-10 VDC BMS External Control Contact 0-10 VDC Boiler Rate Output Contacts 0-10 VDC Variable Speed System Pump Signal Input CHO VDC Signal to Control Variable Speed Boiler Pump Modbus Contacts >TimeOock >Data Logging Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts Last 10 Lockouts >Maintenance Reminder Custom Maintenance Reminder with Contractor Contact Information Installer Ability to De-activate Service Reminder >Low-Water Flow Safety Control & Indication >Password Security >Customizable Freeze Protection Parameters Standard Features >ENERGY STAR Most Efficient Product >95% DOEAFUE Efficiency >Modulating Burner with up to 10:1 Tumdown Direct Spark Ignition Low NOx Operation >ASME Stainless Steel Heat Ex.changer 30 PSI ASME ReliefValve Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon. Tennessee 37090 p, 615.889.8900 IF, 615.547.1000 11 r:J l!ll C Lochinvar.com >Vertical & Horizontal Direct Vent PVC, CPVC, Polypropylene or SS Venting up to 100 feet >Smart System Control >Condensate Trap >Other Features Automatic Reset High Limit Adjustable High Limit w/Manual Reset Boiler Circulating Pump Zero Clearances to Combustible Materials 15-Year Limited Warranty (See Warranty for Details) 5-Year Limited Parts Warranty Optional Equipment 0 CON·X·US® Remote Connectivity 0 Modbus Communication 0 BACnet MSTP 0 Flow Switch 0 Low-Water Cutoffw/Manual Reset & Test 0 Alarm Bell D Concentric Vent Kit 0 SMART SYSTEM™ PC Software 0 Condensate Neutralization Kit 0 BMS Gateway to LON or BACnet IP D Multi-Temperature Loop Control 0 Sidewall Vent Termination 0 Wireless Outdoor Sensor 0 LP Gas Conversion Kit 4/18-Printed in U.S.A. : ·~ KNIGHT XL COMMERCIAL BOILER HIGH EFFICIENCY BOILERS & WATER HEATERS Submittal Sheet . • • I KNIGHT XL COMMERCIAL CONDENSING HEATING BOILERS Job Name: ~c. o \l.._s Model No. \:::~f'.\ 400 Location: Engineer: Wholesaler: Contractor: NOTES: BACK Knight XL Heating Boiler *=~ I ~ 0 0 0 Model No. KBN400 KBNSOI KBN601 KBH701 KBNSOI Notes: Input Gross Min Max Thermal Output MBH MBH Eff. MBH 80 399 94.0% 376 JOO soo 94.0% 470 120 600 94.0% 564 140 700 94.0% 658 160 800 94.0% 752 Type Gas: _ _...~~~.L.U..L...!..•--------- Equipment Tag(s): HIGHVOLTAGE t---1<: .~~E~~CTR~l~CAL~:il~~=======t=====~ GAS CONNECTIONS 00 INLET 38-3/4" H 18-3/4" OUTLET AIR INLET HEAT EXCHANGER DRAIN 314" NPT A 1/4"-1~ ADJUSTABLE FRONT Net AHRI Rating MBH 327 409 490 S/2 654 A B c 42-1/2' I S.1/2' 27-3/4' 42-1/2' I S.l/l' 31-1/l' 42-1/2' I S.l/'l' 36-1/4' 42-1/T IS.l/'l' 40-1/4' 42-1/T I S.l/l' 45-1/4' LEFT SIDE Dimensions and Specifications D G H K 3-3/4' 20-3/4' 21· 14' 34• 34• 2· 18-3/4' 3-3/4' 25-1/'l' 21· 14• 32-1/2" 36' 2" 18' 3-3/4' 25' 21· 14' 36' 32-3/4' S-1/'l' 19-1/'l' 3-3/4' '1.9' 23' 17' 36" 32-3/4' 3-1/4' 23-1/'l' 3-3/4' 33-1/4' 23' 11· 36' 32-3/4' 3-1/4' 27-3/4' Ship Gas Water Air Vent Wt. Conn. Conn. Inlet Size (lbs.) 1· 1-1/l' 4• 4• 280 -~. 4-- 1· 1-1/l' 4• 4• 310 1· T 4• 4• 340 1· T 4• 6' 370 1· T 4• 6' 405 • Indoor installation only. All information subject to change. Change "N• to "L ·for • Lochinvar should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, LP gas models. • The Net AHR/ Water Ratings shown are based on a piping and pickup allowance of 1.15. extensive piping systems, etc_ • The ratings have been determined under the provisions governing forced draft burners. Standard Features > 94% Thermal Efficiency > ModulatingBumerwith 5:1 Tumdown >Direct-Spark Ignition >Low NOx Operation >Sealed Combustion >Low Gas Pressure Operation > ASME Stainless Steel Heat Exchanger > ASME Certified, "H" Stamped Gasketless HEX > 160 psi Working Pressure > 50 psi ASME Relief Valve >Highly efficient, condensing design >Vertical&. Horizontal Direct-Vent >Category IV venting up to 100 feet >PVC, CPVC, Polypropylene or AU9-4CVenting up to 100 Feet >Factory Supplied Sidewall Vent Termination >Smart System Control > Other Features > On/OffSwitch >Adjustable High Limitw/ Manual Reset >Automatic Reset High Limit >Flow Switch >Flue Temperature Sensor > Low Air Pressure Switch >Temperature & Pressure Gauge >Adjustable Leveling Legs >Condensate Trap >Zero Clearances to Combustible Material > 10 Year Limited Warranty (See Warranty) Smart System Features >SMART SYSTEM Digital Operating Control >Multi-Color Graphic LCD Displayw/Navigation Dial >Three Reset Temperature Inputs with curves for three set point temperature inputs > Built in Cascading Sequencer for up to 8 Boilers >Multiple Size Boiler Cascade >Lead Lag >Efficiency Optimization > Outdoor Reset Control with Outdoor Air Sensor > Programmable System Efficiency Optimizers >Night Setback > DHW Night Setback >Anti-Cycling >Outdoor Air Reset Curve >Ramp Delay >Boost Temperature & Time >Three Pump Control > System Pump w/Parameter for Continuous Operation >Boiler Pump With Variable Speed Pump Control* >Domestic Hot Water Pump > Domestic Hot Water Prioritization > DHW tank piped with priority in the boiler loop > DHW tank piped as a zone in the system with the pumps controlled by the Smart System > DHW Modulation Limiting >Separately Adjustable SH/DHW SwitchingTimes* > Building Management System Integration > 0-10VDC Input to Control Modulation or Set Point > 0-10VDC Input Signal from Variable Speed System Pump* > 0-10VDC Modulation Rate Output > 0-10VDC Input to Enable/Disable call for heat >Access to BMS Settings through Display > High Voltage Terminal Strip > 120 VACI 60 Hertz I 1 Phase Power Supply >Three sets of Pump Contacts with Pump Relays > Low Voltage Terminal Strip > 24 VAC Device Relay > Proving Switch Contacts > Flow Switch Contacts >Alarm on Any Failure Contacts > Runtime Contacts > DHW Thennostat Contacts > 3 Space Heat Thennostat Contacts >System Sensor Contacts > DHW Tank Sensor Contacts >Outdoor Air Sensor Contacts >Cascade Contacts > 0-10 VDC BMS External Control Contact > 0-1 o VDC Boiler Rate Output Contacts > 0-10 VDCVariable Speed System Pump Signal Input > 0-1 O VDC Signal to Control Variable Speed Boiler Pump > Modbus Contacts >TimeOock > Data Logging >Hours Running, Space Heating >Hours Running, Domestic Hot Water > Ignition Attempts >Last 1 O Lockouts > Other Features >Low Water Flow Safety Control & Indication >Password Security > Inlet & Outlet Temperature Readout >Customizable Freeze Protection Parameters >Custom Maintenance Reminder with Contractor Info *Exclusive feature, available only from Lochinvar Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon. Tennessee 37090 P: 615.889.8900 IF: 615.547.1000 11 CJ ml C Lochinvar.com Optional Equipment 0Alann Bell D Condensate Neutralization Kit D Concentric Vent Kit (KB400-KB601) DBMS Gateway to LON or BacNet IP D BACnet MSTP Communication D High & Low Gas Pressure Switches w/ Manual Reset (KB501-KB801) D MODBUS Communication D Multi Temperature Loop Control D Low Water Cutoffw/Manual Reset & Test D Boiler Circulation Pump D Variable Speed Boiler Pump D SMART SYSTEM PC Software D Stainless Steel Vent Kits (KB701-KB801) D Stack Frame D 30 psi ASME Relief Valve D 75 psi ASME Relief Valve D 100 psi ASME Relief Valve D 125 psi ASME ReliefValve D 150 psi ASME Relief Valve Firing Codes D M9 Standard Construction D M7 California Code D M13 CSDl I FM I GE Gap (KB501-KB801) Venting Options D DirectVentVertical D Direct Vent Horizontal D Vertical Vent with Sidewall Air Intake D Sidewall Vent with Rooftop Air Intake D Vertical Vent with Optional Room Air D Sidewall Vent with Optional Room Air 11/17-Printed in USA STAINLESS STEEL DIRECTWATERHEATE Submittal Sheet SIT-Sub-02b STAINLESS STEEL INDIRECT WATER HEATERS JOB NAME ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ LOCATION ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ARCH.JEN GR. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~- WHOLESALER ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~- MECH. CONTRACTOR ~~~~~~~~~~~~~~~~~~~~~~~~~~~ MODEL NO. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ GALLON CAPACITY ~~~~~~~~~~~~~~~~~~~~~~~~~~~~ NOTES Standard Features •Fully Welded Construction • 100% Stainless Steel Construction •Built in U.S.A. at Lochinvar World Headquarters • 316L Passivated Stainless Steel Tank • 316L Stainless Steel Heating Coil • l" Boiler Supply and Return Connections • l" Domestic Water Connections (30, 40, 50 models) Optional Equipment Place an X in the box by all options that apply 0AquaStat • 1-1/2" Domestic Water Connections (65, 80, 119 models) • Non-HCFC High Density Foam Insulation •Temperature and Pressure Relief Valve (Shipped Loose) •Factory Supplied Tank Sensor •Warranty -Limited Lifetime Five year limited tank warranty on all models when used in a commercial application. One year warranty on parts. (See warranty for details) Stainless Steel Indirect Water Heater Dimensions & Specifications A D -" . ., BOILER r· .. \ SENSOR WELL G r[ r lr;r I \ t BOILER OUT COLD WATER INLET HOT WATER OUTLET RELIEF VALVE (lhlpped-) Domestic Coil Model Water Connection Shipping Number A B D G H I Conn. Size Wt. (Lbs.) SIT030 39-1/2'' 20" 32-1/4" 21-3/4" 8-1/4" 3" 1" 1" 79 SIT040 55-1/2" 20" 48-1/2" 25-1/4" 8-1/4" 3" 1" 1 ff 105 SIT050 47" 24" 39-3/4" 24-1/2" 9-1/4" 3-3/4" 1" 1" 131 SIT065 60" 24" 52-1/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 147 SIT080 69-1/2" 24" 61-3/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 177 SIT119 68-1/4" 28" 60-1/4" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1 ff 213 Heat Source Standby First Continuous 1st Hour Min. Flow Friction Model Capacity Water Volume Loss Draw Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (°F/Hr) Gals. (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SIT030 27 1.1 1.5 24 160 184 99,000 14.0 3.9 SIT040 40 1.6 0.9 27 181 208 115,000 14.0 4.5 SIT050 52 1.7 0.9 45 210 255 133,000 14.0 5.3 SIT065 67 1.9 0.7 65 263 328 154,000 14.0 5.7 SIT080 82 2.1 0.6 74 266 340 160,000 14.0 5.7 SITl 19 113 3.2 0.5 109 308 418 199,999 14.0 6.5 Peiformance data is based on IWH-TSJ test results. All ratings are based on l 80°F boiler water temperature with incoming cold water at 58°F and a Delta T of 77°F. Includes tank sensor for use with KNIGHT Heating Boiler. Optional thermostat available for use with other boiler models. (Website Update 9/16) 10/15-Printed in U.S.A.