HIGH EFFICIENCY BOILERS & WATER HEATERS Submittal Sheet
FLUE
95 51 44 6"
95 79 69 6"
95 102 89 7-3/8"
95 144 125 7-3/8"
95 185 161 7-1/2"
95 264 229 7-1/2"
KNIGHT FIRE TUBE BOILER
D
D
E
8-3/8" 11-1/8" 10-1/2"
8-3/8" 11-1/8" 10-1/2"
9-3/4" 11-1/8" 10-5/8"
9-3/4" 11-1/8" 10-5/8"
10-1/2" 11-1/8" 11-5/8"
10-1/2" 11-1/8" 11-5/8"
Model No.
Type Gas:
Equipment Tag(s):
AIR INLET
WATER OUTLET
GAS CON NE CTI ON
HIGH-VOLTAGE
ELECTRICAL
CONNECTIONS
LOW-VOLTAGE ELECTRICAL
CONNECTIONS G
H
WATER INLET
CONDENSATE DRAIN
13-1/4" 37-1/2" 32-5/8" 32-1/4"
13-1/4" 37-1/2" 32-5/8" 32-1/4"
14-5/8" 37-3/4" 33' 32-1/2"
14-5/8" 37-3/4" 33' 32-1/2"
15-3/8" 38" 33" 32-3/4"
15-3/8" 38" 33" 32-3/4"
13-1/4" 3-3/8"
13-1/4" 3-3/8"
14" 4-5/8"
14" 4-5/8"
14" 4-5/8"
14" 4-5/8"
43-3/8"
1/4" -1-1/4"
ADJUSTABLE
1/2" 1" T T 160
1/2" 1" T T 165
1/2" 1" 3" 3" 170
1/2" 1· 3" 3" 175
1/2" 1-1/4" 3" 3" 195
1/2" 1-1/4" 3" 3" 205
• Indoor installation only. All information subject to change. Change "N• to "L• for • Lochinvar should be consulted before selecting a boiler for installations having
unusual piping and pickup requirements, such as intermittent system operation, LP gas models. extensive piping systems, etc.
.~
• The Net AHR/ Water Ratings shown are based on a piping and pickup allowance of 1.15. • The ratings have been determined under the provisions governing forced draft burners.
FIRING (ODES
M9 Standard Construction
Ml California Code
Smart System TM Features
>Smart System Digital Operating Control
Multi-Color Graphic LCD Display w /Navigation
Dial, Soft Keys and Loch-N-Link™ USB
programming
>Three Boller Setpolnt Temperature Inputs
Plus Domestic Hot Water Prioritization
>Built-in Cascading Sequencer for up to 8
Boilers, with Cascade Redundancy
Multiple Size Boiler Cascade
Lead Lag
Efficiency Optimization
Front End Loading Capability
>Outdoor Reset Control with Outdoor Air Sensor
Programmable for Three Reset Temperature
Inputs
>Programmable System Efficiency Optimizers
SH Night Setback
DHW Night Setback
Anti-Cycling
Outdoor Air Reset Curve
Ramp Delay
Modulation Factor Control
Boost Temperature & Time
>Four Pump Control
System Pump with Parameter for Continuous
Operation
Boiler Pump with Variable Speed Control
Domestic Hot Water Pu mp
Domestic Hot Water Recirculation
>Domestic Hot Water Prioritization
DHW tank piped with priority in the boiler loop
DHW tank piped as a zone in the system with
the pumps controlled by the SMART SYSTEM
DHW Modulation Limiting
Separately Adjustable Space Heat/DHW
Switching Times
>Building Management System Integration
0-10 VDC Input to Control Modulation or Setpoint
0-10 VDC Modulation Rate Output
0-10 VDC Input to Enable/Disable Call for Heat
>Access to BMS Settings through Graphic LCD
Display
>High-Voltage Terminal Strip
120 VAC I 60 Hertz I 1 Phase Power Supply
Three Sets of Pump Contacts
>Low-Voltage Terminal Strip
DHW Recirculation Pump Start/Stop
24 VAC Device Relay
Proving Switch Contacts
Flow Switch Contacts
Alarm on Any Failure Contacts
Runtime Contacts
DHW Thermostat Contacts
3 Space Heat Thermostat Contacts
System Sensor Contacts
DHW Tank Sensor Contacts
Outdoor Air Sensor Contacts
Cascade Contacts
0-10 VDC BMS External Control Contact
0-10 VDC Boiler Rate Output Contacts
0-10 VDC Variable Speed System Pump
Signal Input
CHO VDC Signal to Control Variable Speed
Boiler Pump
Modbus Contacts
>TimeOock
>Data Logging
Hours Running, Space Heating
Hours Running, Domestic Hot Water
Ignition Attempts
Last 10 Lockouts
>Maintenance Reminder
Custom Maintenance Reminder with
Contractor Contact Information
Installer Ability to De-activate Service
Reminder
>Low-Water Flow Safety Control & Indication
>Password Security
>Customizable Freeze Protection Parameters
Standard Features
>ENERGY STAR Most Efficient Product
>95% DOEAFUE Efficiency
>Modulating Burner with up to 10:1 Tumdown
Direct Spark Ignition
Low NOx Operation
>ASME Stainless Steel Heat Ex.changer
30 PSI ASME ReliefValve
Lochinvar, LLC
300 Maddox Simpson Parkway
Lebanon. Tennessee 37090
p, 615.889.8900 IF, 615.547.1000
11 r:J l!ll C Lochinvar.com
>Vertical & Horizontal Direct Vent
PVC, CPVC, Polypropylene or SS Venting up to
100 feet
>Smart System Control
>Condensate Trap
>Other Features
Automatic Reset High Limit
Adjustable High Limit w/Manual Reset
Boiler Circulating Pump
Zero Clearances to Combustible Materials
15-Year Limited Warranty (See Warranty for Details)
5-Year Limited Parts Warranty
Optional Equipment
0 CON·X·US® Remote Connectivity
0 Modbus Communication
0 BACnet MSTP
0 Flow Switch
0 Low-Water Cutoffw/Manual Reset & Test
0 Alarm Bell
D Concentric Vent Kit
0 SMART SYSTEM™ PC Software
0 Condensate Neutralization Kit
0 BMS Gateway to LON or BACnet IP
D Multi-Temperature Loop Control
0 Sidewall Vent Termination
0 Wireless Outdoor Sensor
0 LP Gas Conversion Kit
4/18-Printed in U.S.A.
: ·~
KNIGHT XL
COMMERCIAL BOILER
HIGH EFFICIENCY BOILERS & WATER HEATERS Submittal Sheet . • • I
KNIGHT XL COMMERCIAL CONDENSING HEATING BOILERS
Job Name: ~c. o \l.._s Model No. \:::~f'.\ 400
Location:
Engineer:
Wholesaler:
Contractor:
NOTES:
BACK
Knight XL Heating Boiler
*=~ I ~
0
0
0
Model
No.
KBN400
KBNSOI
KBN601
KBH701
KBNSOI
Notes:
Input Gross
Min Max Thermal Output
MBH MBH Eff. MBH
80 399 94.0% 376
JOO soo 94.0% 470
120 600 94.0% 564
140 700 94.0% 658
160 800 94.0% 752
Type Gas: _ _...~~~.L.U..L...!..•---------
Equipment Tag(s):
HIGHVOLTAGE t---1<: .~~E~~CTR~l~CAL~:il~~=======t=====~ GAS CONNECTIONS
00
INLET
38-3/4"
H
18-3/4"
OUTLET
AIR INLET
HEAT
EXCHANGER
DRAIN 314" NPT A
1/4"-1~
ADJUSTABLE
FRONT
Net
AHRI
Rating
MBH
327
409
490
S/2
654
A B c
42-1/2' I S.1/2' 27-3/4'
42-1/2' I S.l/l' 31-1/l'
42-1/2' I S.l/'l' 36-1/4'
42-1/T IS.l/'l' 40-1/4'
42-1/T I S.l/l' 45-1/4'
LEFT SIDE
Dimensions and Specifications
D G H K
3-3/4' 20-3/4' 21· 14' 34• 34• 2· 18-3/4'
3-3/4' 25-1/'l' 21· 14• 32-1/2" 36' 2" 18'
3-3/4' 25' 21· 14' 36' 32-3/4' S-1/'l' 19-1/'l'
3-3/4' '1.9' 23' 17' 36" 32-3/4' 3-1/4' 23-1/'l'
3-3/4' 33-1/4' 23' 11· 36' 32-3/4' 3-1/4' 27-3/4'
Ship
Gas Water Air Vent Wt.
Conn. Conn. Inlet Size (lbs.)
1· 1-1/l' 4• 4• 280 -~. 4--
1· 1-1/l' 4• 4• 310
1· T 4• 4• 340
1· T 4• 6' 370
1· T 4• 6' 405
• Indoor installation only. All information subject to change. Change "N• to "L ·for • Lochinvar should be consulted before selecting a boiler for installations having
unusual piping and pickup requirements, such as intermittent system operation, LP gas models.
• The Net AHR/ Water Ratings shown are based on a piping and pickup allowance of 1.15. extensive piping systems, etc_
• The ratings have been determined under the provisions governing forced draft burners.
Standard Features
> 94% Thermal Efficiency
> ModulatingBumerwith 5:1 Tumdown
>Direct-Spark Ignition
>Low NOx Operation
>Sealed Combustion
>Low Gas Pressure Operation
> ASME Stainless Steel Heat Exchanger
> ASME Certified, "H" Stamped Gasketless HEX
> 160 psi Working Pressure
> 50 psi ASME Relief Valve
>Highly efficient, condensing design
>Vertical&. Horizontal Direct-Vent
>Category IV venting up to 100 feet
>PVC, CPVC, Polypropylene or AU9-4CVenting up
to 100 Feet
>Factory Supplied Sidewall Vent Termination
>Smart System Control
> Other Features
> On/OffSwitch
>Adjustable High Limitw/ Manual Reset
>Automatic Reset High Limit
>Flow Switch
>Flue Temperature Sensor
> Low Air Pressure Switch
>Temperature & Pressure Gauge
>Adjustable Leveling Legs
>Condensate Trap
>Zero Clearances to Combustible Material
> 10 Year Limited Warranty (See Warranty)
Smart System Features
>SMART SYSTEM Digital Operating Control
>Multi-Color Graphic LCD Displayw/Navigation Dial
>Three Reset Temperature Inputs with curves for
three set point temperature inputs
> Built in Cascading Sequencer for up to 8 Boilers
>Multiple Size Boiler Cascade
>Lead Lag
>Efficiency Optimization
> Outdoor Reset Control with Outdoor Air Sensor
> Programmable System Efficiency Optimizers
>Night Setback
> DHW Night Setback
>Anti-Cycling
>Outdoor Air Reset Curve
>Ramp Delay
>Boost Temperature & Time
>Three Pump Control
> System Pump w/Parameter for Continuous Operation
>Boiler Pump With Variable Speed Pump Control*
>Domestic Hot Water Pump
> Domestic Hot Water Prioritization
> DHW tank piped with priority in the boiler loop
> DHW tank piped as a zone in the system with
the pumps controlled by the Smart System
> DHW Modulation Limiting
>Separately Adjustable SH/DHW SwitchingTimes*
> Building Management System Integration
> 0-10VDC Input to Control Modulation or Set Point
> 0-10VDC Input Signal from Variable Speed
System Pump*
> 0-10VDC Modulation Rate Output
> 0-10VDC Input to Enable/Disable call for heat
>Access to BMS Settings through Display
> High Voltage Terminal Strip
> 120 VACI 60 Hertz I 1 Phase Power Supply
>Three sets of Pump Contacts with Pump Relays
> Low Voltage Terminal Strip
> 24 VAC Device Relay
> Proving Switch Contacts
> Flow Switch Contacts
>Alarm on Any Failure Contacts
> Runtime Contacts
> DHW Thennostat Contacts
> 3 Space Heat Thennostat Contacts
>System Sensor Contacts
> DHW Tank Sensor Contacts
>Outdoor Air Sensor Contacts
>Cascade Contacts
> 0-10 VDC BMS External Control Contact
> 0-1 o VDC Boiler Rate Output Contacts
> 0-10 VDCVariable Speed System Pump Signal
Input
> 0-1 O VDC Signal to Control Variable Speed
Boiler Pump
> Modbus Contacts
>TimeOock
> Data Logging
>Hours Running, Space Heating
>Hours Running, Domestic Hot Water
> Ignition Attempts
>Last 1 O Lockouts
> Other Features
>Low Water Flow Safety Control & Indication
>Password Security
> Inlet & Outlet Temperature Readout
>Customizable Freeze Protection Parameters
>Custom Maintenance Reminder with
Contractor Info
*Exclusive feature, available only from Lochinvar
Lochinvar, LLC
300 Maddox Simpson Parkway
Lebanon. Tennessee 37090
P: 615.889.8900 IF: 615.547.1000
11 CJ ml C Lochinvar.com
Optional Equipment
0Alann Bell
D Condensate Neutralization Kit
D Concentric Vent Kit (KB400-KB601)
DBMS Gateway to LON or BacNet IP
D BACnet MSTP Communication
D High & Low Gas Pressure Switches w/ Manual
Reset (KB501-KB801)
D MODBUS Communication
D Multi Temperature Loop Control
D Low Water Cutoffw/Manual Reset & Test
D Boiler Circulation Pump
D Variable Speed Boiler Pump
D SMART SYSTEM PC Software
D Stainless Steel Vent Kits (KB701-KB801)
D Stack Frame
D 30 psi ASME Relief Valve
D 75 psi ASME Relief Valve
D 100 psi ASME Relief Valve
D 125 psi ASME ReliefValve
D 150 psi ASME Relief Valve
Firing Codes
D M9 Standard Construction D M7 California Code
D M13 CSDl I FM I GE Gap (KB501-KB801)
Venting Options
D DirectVentVertical
D Direct Vent Horizontal
D Vertical Vent with Sidewall Air Intake
D Sidewall Vent with Rooftop Air Intake
D Vertical Vent with Optional Room Air
D Sidewall Vent with Optional Room Air
11/17-Printed in USA
STAINLESS STEEL
DIRECTWATERHEATE
Submittal Sheet
SIT-Sub-02b
STAINLESS STEEL INDIRECT WATER HEATERS
JOB NAME ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
LOCATION
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
ARCH.JEN GR.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-
WHOLESALER
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-
MECH. CONTRACTOR ~~~~~~~~~~~~~~~~~~~~~~~~~~~
MODEL NO. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
GALLON CAPACITY ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
NOTES
Standard Features
•Fully Welded Construction
• 100% Stainless Steel Construction
•Built in U.S.A. at Lochinvar World Headquarters
• 316L Passivated Stainless Steel Tank
• 316L Stainless Steel Heating Coil
• l" Boiler Supply and Return Connections
• l" Domestic Water Connections (30, 40, 50 models)
Optional Equipment
Place an X in the box by all options that apply
0AquaStat
• 1-1/2" Domestic Water Connections (65, 80, 119 models)
• Non-HCFC High Density Foam Insulation
•Temperature and Pressure Relief Valve (Shipped Loose)
•Factory Supplied Tank Sensor
•Warranty -Limited Lifetime
Five year limited tank warranty on
all models when used in a commercial
application.
One year warranty on parts.
(See warranty for details)
Stainless Steel Indirect Water Heater Dimensions & Specifications
A
D
-" . .,
BOILER r· .. \ SENSOR
WELL
G r[ r lr;r I \
t
BOILER
OUT
COLD
WATER
INLET
HOT WATER
OUTLET
RELIEF VALVE
(lhlpped-)
Domestic Coil
Model Water Connection Shipping
Number A B D G H I Conn. Size Wt. (Lbs.)
SIT030 39-1/2'' 20" 32-1/4" 21-3/4" 8-1/4" 3" 1" 1" 79
SIT040 55-1/2" 20" 48-1/2" 25-1/4" 8-1/4" 3" 1" 1 ff 105
SIT050 47" 24" 39-3/4" 24-1/2" 9-1/4" 3-3/4" 1" 1" 131
SIT065 60" 24" 52-1/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 147
SIT080 69-1/2" 24" 61-3/4" 28" 9-1/4" 3-1/4" 1-1/2" 1" 177
SIT119 68-1/4" 28" 60-1/4" 31-3/4" 9-1/4" 3-1/4" 1-1/2" 1 ff 213
Heat Source Standby First Continuous 1st Hour Min. Flow Friction
Model Capacity Water Volume Loss Draw Delivery Delivery Coil Load Rate Loss
Number (Gallons) (Gallons) (°F/Hr) Gals. (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.)
SIT030 27 1.1 1.5 24 160 184 99,000 14.0 3.9
SIT040 40 1.6 0.9 27 181 208 115,000 14.0 4.5
SIT050 52 1.7 0.9 45 210 255 133,000 14.0 5.3
SIT065 67 1.9 0.7 65 263 328 154,000 14.0 5.7
SIT080 82 2.1 0.6 74 266 340 160,000 14.0 5.7
SITl 19 113 3.2 0.5 109 308 418 199,999 14.0 6.5
Peiformance data is based on IWH-TSJ test results. All ratings are based on l 80°F boiler water temperature with incoming cold water at 58°F and a Delta T of 77°F.
Includes tank sensor for use with KNIGHT Heating Boiler.
Optional thermostat available for use with other boiler models.
(Website Update 9/16) 10/15-Printed in U.S.A.