Loading...
HomeMy WebLinkAboutE18-0142_Bloom equp[1222]_1531321461.pdf SUBMITTAL DATA: RRV°7 A 36NA2 F M-SERIES MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM a 10 Job Name: . /� --- S IPA it ►� id �r System Reference: ` _ ,.iii.>� a, _I AAA Z�i,' 1��` Date: it 0, jig OD IP.' 0 7/1 1/1 8 ii •0 Outdoor Unit MXZ-4C36NA2 ACCESSORIES o 3/8"x 1/2"Port Adapter(MAC-A454JP) o 1/2"x 3/8"Port Adapter(MAC-A455JP) o 1/2"x 5/8"Port Adapter(MAC-A456JP) o 1/4"x 3/8"Port Adapter((PAC-493PI) o 3/8"x 5/8"Port Adapter PAC-SG76RJ) o M-NET Adapter(PAC-IFO1MNT E) o Base Heater(PAC-645BH-E) (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Specifications Model Name Unit Type MXZ-4C36NA2 Rated Capacity Btu/h 35,400/34,400 Cooling* Capacity Range Btu/h 12,600-36,400/12,600-34,800 (Non-ducted/Ducted) Rated Total Input W 3,760/3,940 Rated Capacity Btu/h 36,000/34,400 Heating at 47°F* Capacity Range Btu/h 11,400-43,000/11,400-41,400 (Non-ducted/Ducted) Rated Total Input W 3,020/3,100 Heating at 17°F* Rated Capacity Btu/h 22,200/20,300 (Non-ducted/Ducted) Rated Total Input W 3,340/3,450 Power Supply Voltage,Phase,Hertz 208/230V,1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A 22.1 Voltage Indoor-Outdoor S1-S2 V AC 208/230 Indoor-Outdoor S2-S3 V DC t24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 2.43 Sound Pressure Level Cooling dB(A) 54 Heating 56 External Dimensions(H x W x D) In(mm) 31-11/32 x 37-13/32 x 13 (796 x 950 x 330) Net Weight Lbs(kg) 139(63) External Finish Munsell 3.OY 7.8/1.1 Refrigerant Pipe Size O.D. Liquid(High Pressure) In(mm) 1/4(12.7) Gas(Low Pressure) A:1/2(6.35);B,C,D:3/8(9 52) Max.Refrigerant Line Length Ft(m) 230(70) Max.Piping Length for Each Indoor Unit Ft(m) 82(25) Max.Refrigerant Pipe Height If IDU is Above ODU 49(15) Difference If IDU is Below ODU Ft(m) 49(15) Connection Method Flared/Flared Refrigerant R41 OA Rating Conditions per AHRI Standard: Cooling I Indoor.80°F(27°C)DB/67°F(19°C)WB Heating at 47°F I Indoor.70°F(21°C)DB/60°F(16°C)WB Heating at 17.F I Indoor.70°F(21°C)DB Cooling I Outdoor 95°F(35°C)DB/23.9°C(75'F)WB Heating at 47°F I Outdoor.47°F(8°C)DB/43°F(6°C)WB Heating at 17°F I Outdoor 17°F(-8°C)DB/15°F(-9°C)WB Specifications are subject to change without notice ®2016 Mitsubishi Electric US,Inc. SPECIFICATIONS: MXZ-4C36NA2, contd. I 17. OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP (107 @ 47°F @ 1 Cooling 14 to 115°F(-10 to 46°C)DB /11/18 Non-ducted 19.2 9.4 11.0 3.50 2.67 Heating 5 to 65°F(-15 to 18°C)WB Ducted and 17.6 9.05 10.4 3.38 2.61 Non-ducted Ducted 16.0 8.7 9.8 3.25 2.54 NOTES: • Minimum of two Indoor Units must be connected to the MXZ-4C36NA2. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130%of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: -MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. -MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected,total connected capacity must be 100%or less. • When an MVZ is connected,no P-Series indoor units can be used(PCA,PLA,or PEAD). Notes: Specifications are subject to change without notice ®2016 Mitsubishi Electric US,Inc. DIMENSIONS: M XZ-4C36NA2 � Unit: it 0 JI 07/11/18 6-7/8' 23.518' 6-7/8' Fear Ar 2-13/16' 4-19 2'IIII h,,.,N•I h.• 2-1/32' is ri (Foundation Bat M104 13/32' il =. , ".Lai..�. ._ :=--_ Stile Ai h)ok. , �i�—=iei •- a 1— ,..;:i Hr i .._...._. ........_.....__..__ I[1T_Iani 6-01-/16'Dram H.I- — u Ar bayob,, " 113/32'iw n. !13/32' r. 1-1/2' 2-e7/B'knockoul hole 2-115/32'x1-13/32',Oval Hoe 1-1/2' I (Cunneen .wre hole) (Foundation Bot MO, 1-5/8' II " I 3-0nchetl hole i 3 7 13/32' 31/321� 19/32' I (Connect! •wre hole) • UlIr iinJ 1cHgnpe n iiIIiN"lull OrlilI:I!Il . I N ' 'I - 1.111.: o r!'Ill11111111111u1u116I1!II ��2-3/4' I O :11111I111111111!I9l1111111!lgl111lii Ar Inlae==w o® ; — �IIIIIIIIIIII!!II ulllllu;;,!III!!!!Illllli': ;�y 5}�,!a i. 1 -- 1111111111111111111111)1191111111111!11,1 11� GLA„,,}�,!r Lq 1/<109521F ' p Q® o 1: GAS WS 3rE1e9521FLARE 'lllIIIIIIIIII II!lull: vat als}u.!e l�lll 11111 VII III . Lp} Lq tl<'10b351FLME �r[a p ` It; A "A—VS NOR.r(FLARE �L�._��r -lam J — l • 1 - ,-_ I1-11/32' � -- ` 14-7/32 -- ---- 1.FREE SPACE a. E a '0 8 3-15/16'or more • a- a. 3-15/16'or more U 13-25/32'or more, 2.SERVICE SPACE i -1an .I ,Conduit plates 5 ,fiiiliflyb Conduit connector a pit,` 3-15/16'or more /"---� <I r1 SERVICE SPACE Lock nut 13-25/32'or more II 13-25/32'or more MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ilinl CERTIFIED_ C E I I us .4r,.,cr,vlcyx <- e FORM#MX2-4C36NA2 for Multiple Indoor Unit Styles-201611 ...'.. `""."..."' Intertek Specifications are subject to change without notice. 0 2016 Mitsubishi Electric US,Inc 10 SUBMITTAL DATA: MXZ-3C24NAF ' , M-SERIES MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM ,‘„:17040.40;:e. 41;1 Job Name: rat`ii 1 System Reference: t 1 , I e(U0 a. �� • �- .riaA \ Date: � 94. b 07/11/18 4 _ Aner 11 . 11 Ij 4 Outdoor lirrt MXZ-3C24NA ACCESSORIES 3/8"x 1/2"Port Adapter(MAC-A454JP-E) 1/2"x 3/8"Port Adapter(MAC-A455JP-E) 1/2"x 5/8"Port Adapter(MAC-A456JP-E) M-NET Adapter(PAC-IFO1MNT E) Base Heater(PAC-645BH-E) (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Specifications Model Name Unit Type MXZ-3C24NA Rated Capacity Btu/h 22,000/23,600 Cooling* Capacity Range Btu/h 12,600-22,000/12,600-25,500 (Non-ducted/Ducted) Rated Total Input W 1,620/2,100 Rated Capacity Btulh 25,000/24,600 Heating at 47°F* Capacity Range Btu/h 11,400-30,600/11,400-29,400 (Non-ducted/Ducted) Rated Total Input W 1,750/1,900 Heating at 17°F* Rated Capacity Btu/h 14,000/14,000 (Non-ducted/Ducted) Rated Total Input W 2,120/2,230 Energy Star®(ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) Yes Power Supply Voltage,Phase,Hertz 208/230V,1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A 22.1 Voltage Indoor-Outdoor S1-S2 V AC 208/230 Indoor-Outdoor S2-S3 V DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L-A. 1.9 Sound Pressure Level Cooling dB(A) 51 (Non-ducted/Ducted) Heating 55 External Dimensions(H x W x D) In(mm) 31-11/32 x 37-13/32 x 13 (796 x 950 x 330) Net Weight Lbs(kg) 135(61) External Finish Munsell 3.0Y 7.8/1.1 Refrigerant Pipe Size O.D. Liquid(High Pressure) In(mm) 1/4(6.35) Gas(Low Pressure) A Port:1/2(12.7);Other:3/8(9.52) Max.Refrigerant Line Length Ft(m) 230(70) Max.Piping Length for Each Indoor Unit Ft(m) 82(25) Max.Refrigerant Pipe Height if IDU is Above ODU 49(15) Difference If IDU is Below ODU Ft(m) 49(15) Connection Method Flared/Flared Refrigerant R410A •Rating Conditions per AHRI Standard: Cooling I Indoor 80°F(27°C)DB.67°F(19°C)WB Heating at 47°F I Indoor.70°F(21°C)DB/60°F(16°C)WB Heating at 17°F I Indoor.70°F(21°C)DB Cooling I Outdoor 95°F(35°C)DB:23.9'C(75'F)WB Heating at 47°F I Outdoor.47°F(8°C)DB/43°F(6°C)W B Heating at 17°F I Outdoor 17°F(-8°C)DB/15°F(-9°C)WB Specifications are subject to change without notice 0 2016 Mitsubishi Electric US,Inc. *Ali OF g .5, SPECIFICATIONS: MXZ-3C24NA - _ 41 40 4111111111111111if OPERATING RANGE ENERGY EFFICIENCIES Daq Outdoor Indoor Unit Type SEER EER HSPF C14::.177 • q j 11114 Cooling 14 to 115`F(-10 to 46°C)DB Non-ducted /1)1.6 Heating 5 to 65°F(-15 to 18°C)WB (06+06+09) 20.0 13.6 9.8 4.2 2.97 Ducted and 18.0 12.4 9.5 4.0 2.79 Non-ducted Ducted 16.0 11.2 9.2 3.8 2.61 (09+09+09) NOTES: • Minimum of two Indoor Units must be connected to the MXZ-3C24NA. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130%of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: -MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. -MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected,total connected capacity must be 100%or less. • When an MVZ is connected,no P-Series indoor units can be used(PCA,PLA,or PEAD). Notes: Specifications are subject to change without notice ©2016 Mitsubishi Electric US,Inc .0,011 OFg',! DIMENSIONS: MXZ-3C24NA z- RIM Unit:it 4°o ° t IQ OD'ell 07/11/18 6-7/8' 23 5/e' •-7/8' 8Y lak R@o " @ 2-13/16' 111 1/16• -19/2' 2-1/32. M 1 2-U Oh••ed Notched Hole 13/3Z' in; IFoundotlon Bolt M101 /F. I II ml,% -ie N MISS.L_M �S�_ 111. II, Iiiiimeel SW•e Woke* m N I •_ 6-01-5/16'Dram Hole 8wxnorge�• ry (13/32' ii I 13/32' 2-115/32•x1-13/32.1 Oval Hole 1-1/32' 2-07/8'knockout hole IFoundohon Boll 11101 1-1/2. I IConnech •wee hole) 1-5/B' .. 37-13/32' 31/32• 13' 19/32• .y I (Connecting hole `� !r! IConneClmg hwireed hole) . . !It . I23/4. ____y, -- 0051 II . �� QI FI��I Air Intake I: I Lq 11`U.IC 11* I n I N i WS1Lq t/<'I@6351FL�REOED O® I is Lq tMIBGAS 3+!1@957 FLM E.• I -- O® .b ill • ii4 Gq t�um,A_Lq v<Yo6351FL�RE r=fin-` �1� L 1 WSJ WS trl'1@t])IFLARE 11-11/32' 14.7132' - 1.FREE SPACE im a h g 3-15/16'or more o 0 to Il r i: ,,3-15/16'w more13-25/32'or more gal Conduit plates 2.SERVICE SPACEZii"�i' 1 /r Conduit connector With _.. ::'1441 __� ' P/.i 7.-' Lock nut 3-15/16'w moreII%/i_ SERVICE SPACE 13-25/32'or more 13-25/32'or more MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com AHEM CERTIFIED.. camm FORM#MXZ-3C24NA for Multiple Indoor Unit Styles-201611 '-""•"""_-""' Intertek Specifications are subject to change without notice. ©2015 Mitsubishi Electric US,Inc SUBMITTAL DATA: MSZ-GLO6NA-U1 F NI-SERIES, . 6,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS Job Name: � Iil/ L� lir �;, et System Reference: � � for_ v / -- .. ..".4 �/-� _�i�La �� 1�j t-�pt Date: / �'� 6rr SPECIFICATIONS: �107 Rated Capacity* Cooling' Btulhlw 6,000 ' Heating at 47°F2 Btulh I W 7,200 07/11/18 �. ..,_.. •J'y Rating Conditions perAHRI Standard: Indoor UNC MSZ•GLO6NA•U1 'Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB;Outdoor,95°F(35°C)DB/75°F(24°C)WB Healing al 47°F I Indoor 70°F(21°C)DB/60°F(16°C)WB;Outdoor 47°F(8°C)DB/43°F(6°C)WB For data on specific Indoor units(all ducted,all non-ducted,and both ducted and non-ducted) �. imi combinations,see the MXZ Technical and Service Manual Wireless Remote Controller Applications should be restricted to comfort cooling only,equipment cooling applications are not recommended for low ambient temperature conditions Electrical Power 208/230V, 1-Phase,60 Hz ACCESSORIES: Requirements Indoor Unit Minimum Circuit A 1 o Condensate Pump(BlueDiamond X87-711/721;115/230V) Ampacity(MCA) o Condensate Pump(Sauermann SI30-115/230;115/230V) o Anti-Allergy Enzyme Filter(MAC-408FT-E) o Platinum Catalyst Deodorizing Filter(MAC-308FT-E) Blower Motor(ECM) F.L.A. 0.76 o Drain Pan Level Sensor(DPLS2) Blower Motor Output W 30 Controls o Wireless Controller(MHK1) Field Drainpipe Size O.D. In.(mm) 5/8(15) o Wired Remote Controller PAR-32MAA(Requires MAC-333lF-E) o Wireless Interface for kumo dour"'(PAC-USWHS002-WF-1) Airflow Rate(Quiet-Lo-Med-Hi-Super Hi) o Thermostat Interface(PAC-US444CN-1) DRY 145-170-237-321-399 Cooling WET CFM 109-134-201-286-364 Heating DRY 145-170-237-321-406 Sound Pressure Level(Quiet-Lo-Med-Hi-Super Hi) Cooling 19-22-30-37-43 dB(A) Heating 19-22-30-37-43 External Dimensions In(mm) 11-5/8 x 31-7/16 x 9-1/8 (H x W x D) (295 x 798 x 232) Net Weight Lbs.(kg) 22(10) External Finish Munsell 1.0Y 9.2/0.2 Refrigerant Piping(Flared) Liquid(High Pressure) 1/4(6.35) In(mm) Gas(Low Pressure) 3/8(9.52) Specifications are subject to change without notice 0 2016 Mitsubishi Electric US,Inc. *VI OF gr. ..,,,,i DIMENSIONS: MSZ-GLO6NA-U1 tri � 4 MSZ-GLO6NA-U1 Unit:in.( C b 1/16x1 Oblong hole 1/16013/16 Oblon. ho .?3 Installation plate 3-118 8 7/8 8 118 I/B �, A r ■ r 11/18 1' 31-7/16 30-15/161/4 c w 'IR — - ao II���Il1- .- MN r �� e- ` I�M��II=M=N1I ` J __mIIm�m I .6-1/8 6-1/8 '' iimi _r_,iIr_r_tr_r.�Il - -_ ———--' - 2-3/8 13-5/16 13.9/16 2-1/8 9-1/8 3/16 ——— Indoor unit Allrj 111 all hole .2-9/16 0 — _ Installation .late - Pi,in , .... tt RI . ./ ,II" mnI, 7 ZT :7=-5 1-5/8 1-3/4 1-15/16_ 24-3/8 5-1/B_ 4-3/16"'.7 Drain hose 0 Ell 2-5/1611H II 3/4 - y :I � Air Out r' _ - _ --. .-_ _ ve Insulation a1-3180.0 o a Liquid line 0114 19-11/18(Flared connection 01/4) Tr i5 Gas line 03/8 16-15/16 2-3/16 I-15/16 I I 3/ 6 (Flared connection:03/8(GL86/09112NA),0112(GUM)) Drain hose Insulation 01-1/8 O.D Connected part 05/8 0 D A, MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ARM CERTIFIED.. ,.Augmeaca, (El )us FORM#MSZ-GLO6NA-U1 FOR MXZ-C MULTI-ZONE SYSTEMS-201611 -------- Intertek Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc. SUBMITTAL DATA: MSZ-GLO9NA-U1 F M-SERIES 9,000 BTUIH WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS ,40poirie. . Job Name: 1.0p 1 za !S ► — — 4 - System Reference: ■�Pila� �M Il 1�1 1 Dat t. X,iv y SPECIFICATIONS: �07 di Rated Capacity' Cooling' Btum/W 9,000 07/11/18 Amer Heating at 47°F2 Btum/W 10,900 I iso Ratin Conditions .-..-_ g per AHRI Standard: Indoor Unit:MSZ-GL09NA•U1 'Cooling I Indoor.80°F(27°C)DB/67°F(19°C)WB;Outdoor:95°F(35°C)DB/75°F(24°C)WB Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB,Outdoor 47°F(8°C)DB 143°F(6°C)WB For data on specific indoor units(all ducted,all non-ducted,and both ducted and non-ducted) .Poime, combinations,see the MXZ Technical and Service Manual Wireless Remote Controller Applications should be restricted to comfort cooling only,equipment cooling applications are not recommended for low ambient temperature conditions Electrical Power 208/230V, 1-Phase,60 Hz ACCESSORIES: Requirements Indoor Unit Ccuit o Condensate Pump(BlueDiamond X87-711/721;115/230V) Ampacity(MMinimum(MCAA)) A 1.0 o Condensate Pump(Sauermann SI30-115/230;115/230V) o Anti-Allergy Enzyme Filter(MAC-408FT-E) o Platinum Catalyst Deodorizing Filter(MAC-308FT E) Blower Motor(ECM) F.L.A. 0.76 o Drain Pan Level Sensor(DPLS2) Blower Motor Output W 30 Controls o Wireless Controller(MHK1) Field Drainpipe Size O.D In.(mm) 5/8(15) o Wired Remote Controller PAR-32MAA(Requires MAC-3331F-E) o Wireless Interface for kumo clouem(PAC-USWHS002-WF-1) Airflow Rate(Quiet-Lo-Med-Hi-Super Hi) o Thermostat Interface(PAC-US444CN-1) DRY 145-170-237-321-399 Cooling WET CFM 109-134-201-286-364 Heating DRY 145-170-237-321-406 Sound Pressure Level(Quiet-Lo-Med-Hi-Super Hi) Cooling 19-22-30-37-43 dB(A) Heating 19-22-30-37-43 External Dimensions 11-5/8 x 31-7/16 x 9-1/8 (H x W x D) In.(mm) (295 x 798 x 232) Net Weight Lbs.(kg) 29(12) External Finish Munsell 1.OY 9.2/0.2 Refrigerant Piping(Flared) Liquid(High Pressure) 1/4(6.35) In.(mm) Gas(Low Pressure) 3/8(9.52) Specifications are subject to change without notice 0 2016 Mitsubishi Electric US,Inc. ..„...." II DIMENSIONS: MSZ-GLO9NA-U1 � 4 MSZ-GLO9NA-U1 Unit:in.( C b 1/16x1 Oblon. hole 1/16x13/16 Oblon. ho Installation dale 3-1/8 8 1/8 8 1/8 I/B ,A mat ' 1/18 11/l6 30.15/16 I/4 c w rr7"—.1.1MMiiMINIMMs O r - I '_1 __I1_�_.Ii _ iilimm��immim.mi, - [ .6-1/8I 6-1.....__._ ___f — •'-- --- - 2-3/8 13-5/16 13-9/16 ,2-1/8 9-1/6 3/16illill Indoor unit Air In all hole 42 9/16 I b Installation .late .. / pi.. z411 ..... , u., ,z, II r , _ _ , ..... „ ..., . \ III.'r_.... <. • ( 1-5/8 1-3/4 1-15/16_ 24.3/8 5-1/8, 4-3/16,;,ti Drain hose 2-5/16 I I it 3/4 — Ir I AbouHeti t ^ Insulation o1-3/8 O.D - ��I l� • .E4 Liquid line o1/4 19-11/16(Flared connection o1/4) 2-3/16 I-15/16 'n. Gas line e3/816-15/16 I-3/16 (Flared connection:03/8(GLOG/09/12NA),e1/2(GL15NA)) IDrain hose Insulation e1-1/8 0.D Connected part 05/8 0 D MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA 30024 Toll Free:800-433.4822 www.mehvac.com _ cats nu :CE'RTIFIED� FORM#MSZ-GLO9NA-U1 FOR MXZ-C MULTI-ZONE SYSTEMS-201611 .: � �c-�. oa Intertek Specifications are subject to change without notice 0 2016 Mitsubishi Electric US,Inc SUBMITTAL DATA: MSZ-GLI8NA-U1 & MUZ-GLI8NA-U1 OF , M-SERIES 18,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Job Name: MA id r System Reference: r` `Azr � y ?Zai Date: - i..7l. bt •-- Electrical Power "1 q ] Requirements 208/230V, 1-Phase,60 Hz 07/11/10 Minimum Circuit Ampacity(MCA) Indoor Unit MSZ-GLI8NA-U1— •-' I 0 Indoor/Outdoor A 1 /14 Wireless Remote Controller Outdoor Unit.MUZ-GL18NA-U1 Indoor Unit ACCESSORIES: Blower Motor(ECM) F.L.A. 0.67 Indoor Unit Blower Motor Output W 30 o Condensate Pump(BlueDiamond X87-711/721;115/230V) o Condensate Pump(Sauermann S130-115/230;115/230V) SHF/Moisture Removal 0.87/2.1 pt./h ❑ Anti-Allergy Enzyme Filter(MAC-408FT E) ❑ Drain Pan Level Sensor(DPLS2) Field Drainpipe Size O.D. I In.(mm) 5/8(15) Outdoor Unit Outdoor Unit o Outdoor Mounting Pad(ULTRILITE1) Compressor DC INVERTER-driven Twin Rotary o Drain Pan Heater(MAC-642BH-U) o 3-1!4"Mounting Base[Pair](DSD-400P) Fan Motor(ECM) F.LA. 0.93 o Drain Pan Socket(MAC-851 DS) ❑ Air Outlet Guide(MAC-886SG-E) Airflow Rate(Quiet-Lo-Med-Hi-Super Hi) ❑ Wall Mounting Bracket(QSWB2000M-1) Indoor DRY 259-333-416-523-646 Controls (Cooling) WET 233-300-375-470-581 o Wireless Controller(MHK1) ❑ Wired Remote Controller PAR-32MAA(Requires MAC-3331F-E) Indoor CFM o Wireless Interface for kumo cloud TM'(PAC-USWHS002-WF-1) (Heating) DRY 296-384-469-563-646 o Thermostat Interface(PAC-US444CN-1) Outdoor 1,691 /1,691 SPECIFICATIONS: Sound Pressure Level(Quiet-Lo-Med-Hi-Super Hi) Rated Conditions(Capacity/Input) Cooling 28-33-38-44-49 Cooling' Bluth/W 18,000/1,340 Indoor Heating 28-33-38-43-48 Heating at 47°F2 Bluth/W 21,600/1,680 dB(A) Cooling 54 Outdoor Capacity Range Minimum Maximum Heating 55 Cooling' Btu/h 5,800 22,000 External Dimensions Heating at 47°F2 Btu/h 5,400 25,000 Heating at 17°F' Blum - 18,200 Indoor(H x W x D) 12 x 36-5/16 x 9-13/16 (305 x 923 x 250) Heating at 5°F4 Bluth - 14,500 — In.(mm) Outdoor(H x W x D) 34-5/8 x 33-1/16 x 13 'Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB;Outdoor.95°F(35°C)DB/75°F(24°C)WB' (880 x 840 x 330) 'Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB;Outdoor:47°F(8°C)DB/43°F(6°C)WB' 'Heating at 17°F I Indoor.70°F(21°C)DB/60°F(16°C)WB;Outdoor.17°F(-8°C)DB/15°F(-9°C)WB' 'Heating at 5°F I Indoor:70°F(21°C)DB/60°F(16°C)WB:Outdoor 5°F(-15°C)DB/5°F(-15°C)WB Net Weight •Rating Conditions per AHRI Standard: Indoor 28(13) Lbs.(kg) Operating Conditons(Indoor Intake Air Temp.)(Max/Min.) Outdoor 121 (55) Cooling2° 90°F(32°C)DB/67°F(19°C)DB External Finish Heating 80°F(27°C)DB/70°F(21°C)DB Indoor Munsell 1.0Y 9.2/0.2 Operating Conditons(Outdoor Intake Air Temp.)(Max./Min.) Outdoor Munsell No.3Y 7.8/1.1 Cooling5 115 F(46°C)DB/14°F(-10°C)DB Refrigerant R410A;3 lb.9 oz. Heating 75°F(24°C)DB/-4°F(-20°C)DB- 'Applications B"'Applications should be restricted to comfort cooling only;equipment cooling applications are not Refrigerant Piping(Flared) recommended for low ambient temperature conditions -System cuts out at-9°F(-27°C)to avoid thermistor error and automatically restarts at-4°F(-20°C) Liquid(High Pressure) 1/4(6.35) In.(mm) Gas(Low Pressure) 1/2(12.7) AHRI Efficiency Ratings SEER/HSPF 20.5/11.2 Max.Total Refrigerant 50(15) Pipe Length(Height Diff.) COP at 47°F/17°F 3.77/2.73 Ft.(m) Max.Total Refrigerant 100(30) Pipe Length(Length.) Energy Stand Yes ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Jpecincanons are subject to cnange wnnout notice. ®2016 Mitsubishi Electric US,Inc. DIMENSIONS: MSZ-GL18NA-U1 & MUZ-GLI8NA-U1 z- 5 MSZ-GLI8NA-U1 Unit:in.( 43 .....pAppoliii: z ono 7/16%13116 " -1gOD NJ Installation plate Oblong hole Indoor unit 1 n7/16 Oblong hole3.111rt1/11/18 -, 36-916 J L 3.11116 8-7/8 8-7/8 11 Ir m 35.13116 Ilik 1r4 � %. ie II d ,a, I a II ) 9-13/16 s 8.11/16 ,,, 8.1116 . e 3/16 - 2-916 15-7/8 r 15.3/16 , �3 I Air in Wall hole 03 Installation.ate RI s 1 2-112 2-1/16 'tit 27.19166.916 . I!!ll.—�/. N. /II Drain hose 2-5/16�r 3/4 , * TT7T=1 2-9/16 0. I I 'Il� ���'� 1.7 EH �I ffil Air out 111= 5-3/4 111 J r 2-9/16 2-9116 m 1 r 3-11/16 rn Insulation 02 O.D . Liquid line 05/16 15-3/8 (Flared connection 01/4) elGas line 015/32 13-3/8(Flared connection 01/2) Drain hose Insulation 01-1/8 Connected part 05/8 0.D Unit:in.(mm) MUZ-GLI8NA-Ut- REQUIRED SPACE '1 20 in.(500 mm)or more when front and sides of the unit are clear 16-7/16 �� 1 Drain hole 01-5/8 00 Air in 1-9/16 9 '�p• e II it. if r/Ips `\\o r--::=- 111mt ,tA _� \n °uta —� 40``' yl ,�p� ►11 I About 2-holes 13/32x13/16 20' O�R�\ ,0Y'� o7 500,07 6-7/8 619.11/16 of �'���1�`titi,,,, '2 When any 2 sides of left,right and rear of the unit are clear 33-1/16 3716 4-5/16 Service panel • . .=a I Liquid refrigerant pipe Joint i �`�� Refrigerant pipe(flared)01/4(GL18) . MITSUBISHI / Refrigerant pipe(flared)o 3/8(GL24) a kiefrifinsi - - - i li /� ELECTRIC '111' � COOLING & HEATING —1 M/'ileo /!I 1340 Satellite Boulevard.Suwanee,GA30024 Gas refrigerant pipeJointlu 4---- te' I=-1 Refrigerant pipe(flared)012(GL18) Toll Free:800-433-4822 www.mehvac.com r'_! ' ---_�- - Refrigerant pipe f flaredl a 5/81 GL24) �i CERTIFIED. E- us „HmM Y 71V10 FORM#MSZ-GL18NA-U1—MUZ-GL18NA-U1-201611 Intertek Specifications are subject to change without notice. ©2016 Mitsubishi Electric US,Inc.