HomeMy WebLinkAboutE18-0142_Bloom, Audree Load Calc_1531321458.pdf ,siti OF to
.15
4
Sheet1
1374 Sandstone Drive Load Calculation 01
Existing service=200A main 07/11/18
Totals
NEC 220.83B
Airconditioner East 4840 VA @100%
Airconditioner North 5280 VA @100%
Bath Floor Heat 1.5 KVA @100% 11620
General light 3VAx3000 sq ft 9 KVA
Small Appliance 2x1.5KVA 3 KVA
Laundry 1.5 KVA
Refridgerator 1 KVA
Dishwasher 1.2 KVA
Disposal 746 VA
Microwave 1.5 KVA
Master Tub 1.3 KVA
Range 8 KVA
Dryer Gas NA
Heat Tape 3 KVA
water heater Gas NA 30246VA
-8000
1st 8 KVA @100% 22246
22246 @40% 8898
1st8KVA@100% 8
Remainder @ 40% 8898
Airconditioning and heat loads @100% 11620
28518
Total Load 28518
28518/240V=118AM PS
Existing service=200A main
Page 1
°F I/4
4...74011111111441;110.0
Sheetl
9-45.01 eft.
IQ0711
07/11/18
VA
VA
VA
KVA
VA
VA
VA
VA
Page 2