Loading...
HomeMy WebLinkAboutE18-0142_Bloom, Audree Load Calc_1531321458.pdf ,siti OF to .15 4 Sheet1 1374 Sandstone Drive Load Calculation 01 Existing service=200A main 07/11/18 Totals NEC 220.83B Airconditioner East 4840 VA @100% Airconditioner North 5280 VA @100% Bath Floor Heat 1.5 KVA @100% 11620 General light 3VAx3000 sq ft 9 KVA Small Appliance 2x1.5KVA 3 KVA Laundry 1.5 KVA Refridgerator 1 KVA Dishwasher 1.2 KVA Disposal 746 VA Microwave 1.5 KVA Master Tub 1.3 KVA Range 8 KVA Dryer Gas NA Heat Tape 3 KVA water heater Gas NA 30246VA -8000 1st 8 KVA @100% 22246 22246 @40% 8898 1st8KVA@100% 8 Remainder @ 40% 8898 Airconditioning and heat loads @100% 11620 28518 Total Load 28518 28518/240V=118AM PS Existing service=200A main Page 1 °F I/4 4...74011111111441;110.0 Sheetl 9-45.01 eft. IQ0711 07/11/18 VA VA VA KVA VA VA VA VA Page 2