HomeMy WebLinkAboutB08-0130� Community Development Department 75 South Frontage Road Vail, Colorado USA 81657 CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Title 10, Section 10-1-2, ADOPTED CODES of the Vail Town Code certifying that, at the time of issuance, this struciure was found to be substantially in compliance with the various ordinances of the town regulating building construction or use for the following: Name and description of project Address of project: 4220 [n] Residence Owner name and address: Scott Goldman, Maryalice Cheney, 26 Summit Street, Philadelphia, PA 19118 IBC Edition: 2003 IBC Occupancy Group(s): R3 Type(s) of Construction: VB Permit Number(s): B08-0130 Occupant Load: Martin Haeberle, Chief Building Official Sprinkler System Y/N Type: Q 3 D Date NOTE: THIS PERM/T MUST BE POSTED ON JOBSITE AT ALL TIMES : �ow�o�vnII; ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.4792149 ADD/ALT SFR BUILD PERMIT Job Address: 4220 SPRUCE WAY VAIL Location......: 4220 SPRUCE WAY Parcel No....: 210112226001 OWNER GOLDMAN, SCOTT M. - CHENEY, 05/O6/2008 26 SUMMIT ST PHILADELPHIA PA 19118 APPLICANT C& H CONSTRUCTION, LLC 05/O6/2008 Phone: 970-949-1502 PO BOX 341 AVON COLORADO 81620 License: 822-B CONTRACTOR C& H CONSTRUCTION, LLC 05/06/2008 Phone: 970-949-1502 PO BOX 341 AVON COLORADO 81620 License: 822-B ARCHITECT VAG, INC. ARCHITECTS & PLANN 05/06/2008 Phone: 970-949-7034 PO BOX 1734 VAIL CO 81658-1734 License: C000002386 Description: GOLDMAN/CHENEY REMODEL ADDITION & INTERIOR REMODEL Occupancy: Type Construction: Permit #: Project #: Status . . : Applied . . : issued . .. : Expires . ..: Valuation: Total Sq Ft Added: B08-0130 PRJ07-0565 ISSUED 05/06/2008 0611112008 12/08/2008 �.0� 1 �� � � �` �^� v, �� �- �f``� �1 $330,000.00 499 itRfi##tf�tRlrY�Y�ffR1't�#i4RRR�fi(iF4iRf'1r4frif4f4#}ikttlklr*iriikYr�R��t4it#ffet`4}'4fV��RM'k1rRw* FEE SUMMARY •••,•••••••••••••••,,•_••»••••••••••,•••«•,•••••••••••,•••••••_••••,,•••,,••,,, Building Permit Fee----> $2,281.75 Will Cal Fee---------------------� $4.00 Total Calculated Fees-------------> $10,318.59 Plan Check------------------> $1,483.14 Use Tax Fee-------------------> $6,400.00 Additional Fees----------------------> $0.00 Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES------------> $10,318.59 Investigation--------------> $0.00 Recreation Fee-----------------> $149.70 Payments-----------------------------> E10,318.59 Total Calculated Fees--------> $10,318.59 BALANCE DUE------------------------> 30.00 •4Y#tiRf�Yr1rYY4RRliY`4rt V tkf�4rtY41'tr V RfftRtn�ik*'kY4fl4tttRYrf'ftr#ik+'f#w*#4RfZlrfi'iYr�fiL�A'tR1�f x4trt#�kt�#fAflRf*t#'frYxfiiYrttYrxirtirffllrf#ffM�Rxwt�ii'f4iRYi+iLY`xx*1MNrt/t�tt#YriRRteftf tifi*if'kft4ttf'kffl�i#fYrtf}ti DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town� zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. � „ REQUESTS 8:00 AM - 4: or Print Name bld_alt_construction_perm it_041908 BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM �'11-U$ Date •t�xrt�r��t��ir+�wxx�w:�+te�wr��++rritx���wr�xrerwe���xxiww::e�:�xx�rw�:::i���r�+r��x�xxw+iyxew�w�����trwiie.+��iwwwxrrrx:����+wwrrx�tt�ir+�w�rrtwwtxt��i::tw�++��:t+���i.i.�e:�:���wvwr APPROVALS Permit #: 608-0130 as of 06-11-2008 Status: ISSUED •eeewxw:�w�wwrrNxrx:�.wx�wwrewex��.r��r�w�vrxx��+r��xx����e,eyix�w+��r+Mn�::w�:w+xrerw:�:�.����e�xrxx�x��r++r�wwxx+���r+xrxxrtwt:�wx++:xrrr�►wk+r+xwxxrw�.�e�w�,ew��xx,r,vwe��s.xx:�i::ri�htt Item: 05100 BUILDING DEPARTMENT 05/22/2008 jplano Action: CR F:\cdev\CHRIS\PERMIT.COMMENTS\B08-0130\608-0130. DOC 06/06/2008 jplano Action: AP see red lines and conditions Item: 05400 PLANNING DEPARTMENT 05/08/2008 NPETERSON Action: AP PLANS APPROVED DATE STAMPED 05/06/2008. REF DR608-0047. Item: 05600 FIRE DEPARTMENT 05/28/2008 JJR Action: AP APRROVED PLANS RECEIVED 5/06/08 Monitored fire alarm system required and shall comply with NFPA 72(2002) and VFES standards. Fire sprinkler system recommended. }tt41'Zlfitifl�tYih4Y!lRR4fOy'YY11rRRR*ftY�4Y1rV 1rf�ffy'fYTffflrRRieltk9'f V f#R+1#fttYfff�f�tttRt+�1`t�i`'kMy'fY�R}RMfY.RfNfwfftlrYYMH1f1fRf'kfkYxtlrV#f!f'kffY�1L#R**ttbYifkti4y'fYffff#k*#rtf VR4ff4Y�f4f}fr4R�i See the Conditions section of this Document for any that may apply. bld alt_construction_permit_041908 �WYkw4fwwYw�k*�/xk***tRAR�Rk##Rl��Rk4Rfw����R��fx�ffRR�ff�flflxx��f���ftffiK��R����ii*#�l�kRR�*R�ff1f�l��k/#�fif4xix##4f�w���wifRRW#f!�!M#iYw*wkMfXwlWwwwwlfYY�MfRlk�fwfl��lflRfRf�ff CONDITIONS OF APPROVAL Permit #: 608-0130 as of 06-11-2008 Status: ISSUED .RR+x����:�x�wix:�xirirw�rix�:�ttt�x:t�:txw�rh►e��:a�i��i��R�x��+ix:�wx�xr+:t��:wixxx�,rx�rtxr�:+�t��i��+.�,��+�+��������w�+��wias��,r�r3:+�������r��itrr+ww�t�,rvrr�r,rwexr�y�eee�xxx��exe Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: CON0010060 THE NEW DECK IS TOO CLOSE TO THE PROPOERTY LINE , IT NEEDS TO BE ONE HOUR OR MOVED 3' FROM THE PROPERTY LINE Cond: 16 (BLDG.): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R313 OF THE 2003 IRC. bld alt_construction�ermit_041908 ***********************«***�****�**+*�*��*******************r****************�++*++*�s****** TOWN OF VAIL, COLORADO Statement ******.*********************************++**********:****r********************�************* Statement Number: R080000931 Amount: $149.70 06/11/200811:45 AM Payment Method:Credit Crd Init: LC Notation: RICHARD CAPLES VIA CREDIT CARD Permit No: Parcel No: Site Address: Location: B08-0130 Type 2101-122-2600-1 4220 SPRUCE WAY VAIL 4220 SPRUCE WAY ADD/ALT SFR BUILD PERMIT Total Fees: $10,318.59 This Payment: $149.70 Total ALL Pmts: $10,318.59 Balance: $0.00 *�*****�*****************�*+*�*�*********r************�*******�+*****�********************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ RF 11100003112700 RECREATION FEES 149.70 , � APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSI b Project #: �' ' � �� Buildin Permit #: � � . :, � 3 � ,�i } u , ) ����'� � TOWN OF VAIL BUILDING PERMIT APPLICATION Separate Permits are required for electrical, plumbing, mechanical, etc.! 75 S. Frontage Rd. Vail, Colorado 81657 CONTRACTOR INFORMATION General Contractor: Town of Vail Reg. No.: Contact Person and Phone #'s: c� N Cc�►►tr�r,�d ��-c. � �$2t-B �ch �'� s 4- � so � Email address: ._ L a/�,,.,/,J/`,�sti_ rew, Fax #: 4 y��/ j�rj PLETE VALUATIONS FOR BUILDING PERMIT ***�*�******,t,t**********,�*******�*******FOR OFFICE USE ONLY*�*****��*,�*�*****�****,�***�**********,t,t�** T�tpe of Caristruc�on: �� Date Recerved: mm- � � dcGUpart�'� Group. Acc�pted By. F:\cdev\FORMS\Permits\Building\buildin�permit_4-21-06. DOC p ���o�� MAY 0� 2008 Pa9���11N OF VAIL�Z1�2o t , �nw�oFV� � -1 ASBESTOS TESTING REQUIREMENTS THE TOWN OF VAIL AND STATE OF COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTING ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED. AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITION OR REMOVAL OF BUILDING MATERIALS THAT MAY CONTAIN ASBESTOS. BUILDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVE NO ASBESTOS CONTAINING MATERIALS ARE EXEMPT. A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION • I have included the asbestos test and report with my building permit application I� i� ��t-C � ttti�� �/'r��� i�c I�,S� OR o� Svn�✓ • I certify my project will not disturb or remove more than 160 s.f. of building material. The construction plans submitted with my application clearly indicate this information. (This will be verified during plan review, and will delay your project if found to be inaccurate) applicant signature date OR • The building was constructed after October 12, 1988. The date of construction was original construction date applicant signature date F:\cdev\fORMS\Permits\Building\building_permit_4-21-06.DOC Page 4 of 16 04/21/2006 ******************************************************************************************** TOWN OF VAIL, COLORADO Statement **s**********************************************************ss***************************** Statement Number: R080000626 Amount: $10,168.8905/06/200803:16 PM Payment Method: Check Init: SAB Notation: 8677 C &H CONSTRUCTION ----------------------------------------------------------------------------- Permit No: B08-0130 Type: ADD/ALT SFR BUILD PERMIT Parcel No: 2101-122-2600-1 Site Address: 4220 SPRUCE WAY VAIL Location: 4220 SPRUCE WAY Total Fees: $10,168.89 This Payment: $10,168.89 Total ALL Pmts: $10,168.89 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code -------------------- BP 00100003111100 PF 00100003112300 UT 11000003106000 WC 00100003112800 Description ------------------------------ BUILDING PERMIT FEES PLAN CHECK FEES USE TAX 4$ WILL CALL INSPECTION FEE Current Pmts 2,281.75 1,483.14 6,400.00 4.00 ----------------------------------------------------------------------------- 05/14/2008 �YED 12:27 . FAg 9709491541 I / � 1 ASBESTOS INSPECTION AND SAMPLYNG REPORT Goldman Residence - 4220 Spruce Way in Vail, CO 81657 Presented to: C & H Construction, LLC 281 Metcalf Road Avon, CO 81620 Pcrformed by: Mr. Bra.ndon Sinkbeil DS Consulting, Inc. Pp Box 6864 Avon, CO 81620; DSC Project # 0443 May 12, 2008 DS Consulting, Inc. � �nmalrhe��l C�rt�tl+•nt�,�2ti_ Suprriur Fteyuli�, n������ U MAY 14 2008 I TOWN OF VAIL f� 002/013 05/14/2008 �YED 12: 27 FAX 970 I491541 C� 003/013 EXECUTIVE SUlVIIVIARY On May 7, 2008, Mr. Brandon Sinkbeil of DS Consulti.ng, Inc. (DSC) perFormed an inspcction and limited asbestos sttmpling at 4220 Sptuce Way ui Vail, Colorado, iz� order to identify patentially haza�rdnus friable aad non-&iable asbestos contair�ing material.s (ACM) within a portion of � he sb�ve-reference�, single-family residence_ Mr. Brandon Sinkbezl pei�furmed �.gbestns lrulk sampluig of various surfacang materials on shccttock in a total �f three (3) locations within the resid�ncc. All thr'ee (3) butk samples wcre analyzed by Reservoirs Environmental, Ine. with all laboratory resulls bcing non-detect for ACM (see Appendix A for laboratory results). 05/14/2008 {VED 12:27 FA% 9709491541 i. Tntroduction f� 004/019 An inspection aud bulk sampling for ACM was conducted at 4220 Spntcc Way in Vail, Colorado, by Mr. Brandon Sinkbeil on May 7, 2008, �t ihc rcquest of C& H Conslructi�n, LLC in Avon, CO. Mr. Sinkbeil is a Colorado Slate Cc�'tx�ied inspector, and has EPA Accreditation #13442 (see Appenciix B for a c��py of tlus certificate). Thc purpose of the inspection was to idcatlfy, sample and assess potenti�lly hazardous friable and non-&iAble ACM in a portion of the single-�nmily residencc rcfcrcnccd above schedt,led for a rein�deling. II. Structnral Design 'fhe y�rue�ure is a wuod-framcd, single-ffunily home. ��. Sampling and Analytical Proccdures The ins�eetion and assessmetit were conducted by an EPA and AHERA accreciite�l Inspector qualified by experience, educ�tion and uai.nin� in the rec�gnition of poteniial ACM and approved bulk s�wapling I.u;lnniqu�s. Th� r�.sUestos bullc szttnplin� was conducted on suspecl AGM with a l�imited num�er of bulk samples being collected in the residence. The inspecti�n and �i�sessment wer� nerformed in accordance with EnvironmentAl Protec:tion �1,gency/AfiERA recpmmended procedures. Thcse procedures call for th�e visual insPection of tlie area of coiicein and collection and aa�filysis of repre�en�tttive bulk samples of suspeet matcrial. Some minor destruclive sampling was conducted. Walls, columns and �erimeter pip� chases wcrc not broken into in order to locate and quantify suspect ACM. [t sliould be notcd thAt additional ACM might be localed in ol,hcr inaccessiUlc are�.s. Raz�doztx bul� samples, representative of the suspcct asbestos-containing building materials (AC.BM} of eacli houiobenevus ��a (HA), were collected �ccvrdin� lo the �uidelines published �s Environmcntal Proiection Agency (EPA) Fin�l Rule: Title iT of the Toxic Substanccs Cantrol Act (TSCA), 15 USC, Seclioas 2641 througli 2654 and in compliance with 4Q CFR, Part 7tS3. itepresenlative sampling is U�.�ed on the following criteria: 1. The clislribution of the suspect inaterial l.hroufibout the [ IA. 2. The suspect material's physical eharacteristics and applieation. 3. Ranclum samplin� patterns detennined for cach FTA. Suspect materials sampled and ancilyzed should be c�nsidered to be represcntative of materials in each HA if: 1. They exhibit sunil�r physical eharaeteristics; and 2 05/14/2008 �VED 12:27 FA% 9709491541 2, Thc applicati�m c�f the sa�npled inaterial can be c;orrclatcd to the application of unsam�led material. Bulk sampl�s collected wzre analyzed utiliziug the EPA's �Vtcthod for the Determination of Asbestos in_Bulk Buildin� Materi�ls (EPA 600/R/116, July, 1993) and the McCmnc Research Institute'S•The Asbebtos Pariicle Atlas as method.s refereuces. Analysis of the bulk samples was performcd oa the "date reported," as listed in ihc bulk- sampl� analysis rcpon. iV. Notes on Report Format Suspeet materials alike in appearrsinnce and application were sampled as FIAs_ Suspect materials were divided into three classiGcarians: 1. Surfacin� z�aatc�a�: sprayed ar troweled onto slructural building member. 2. Thennal systems insulation: any type uf pipc, boiler, tank, or duct insul�ition. 3. Miscellaneous: othcr suspect materials, including floorin�;, ceiling �il�s, insulatinn, aud fmishing matcrials. C'ondition assessm�nts were perFormcd by tbe accredited inspector a� the timc of inspection. Condition assessmentS are listed in the followi.n6 secHon. Ratings of "good," "d�unaged," ancl "severely dnmaged" are me�uzt to indicate the overall condirinn af the material. A material in "g��od" condition has nu visible d�ma�c or dcterioration, or showing only very limited damage or deteriora�ion. A material in "damaged" condition has the following eharaetex'istics: Thc surftu:c is crumbling, blistered, water-stained, gouged, marred or otherwise abraded over less than one-tenlh of ihe surface if the d�nage is evenly distributed (on�-quarter ix thc damage is localized). Accumulatipn ofppwder, dust or debris siruil�r in appeatanee tp the suspect n�aterial an surfaces beueatl3 tlie �terial c�� be used as eontirmatory evidence. A material in "severely dfunaged" condition has one or �more of the followuig characterisiics: The surface is crumblin� or blistered over at least one-tcnth of thc surface if l.hc cl�ma�;e is ev�nly distributed (one-qu�,tter if the tiamage is l�calized). One-tenth (one-nuarter, if localizcd) �f the inateri.al is han�,►ing from thc surface, c�teriarated, Or showing adhesive iailur�. • Water stains, gouges, or mars �re ovcr at lcast one-tenth �f the surface if lhe dama�e is evenly dislribulcd (oz�e-quaiter if the dan�ge is localized). l� 005/01� 05/14/2008 WED 12:28 FA% 9709491541 Accurz�ulation u f powdcr, dust or debris siinilar in appe�nce 10 tb�c suspect material on surtaces heneath the material can be used as confirmslory evidznCe. R�SpUI1SC-aCl10II i�CO1X1Ii)�flc�StIpI1S f01• asbestos coutainiug HAs are alsa listed in the following section. Recommendations may be for more than one HA, if materi�ls are alike. Recommendati�ns are eilher "general" or "immediate." An nnmeciiate recoramcradation indicates an imminent hazard exists �nd should be addressed as soon as possible. V. Iuspector Comments No ACM was identified ciuring ihe bulk sampling conducted at 4220 Spruee W�y in Vail, Colorado. A total of three (3) bulk sfunples were colleet�d &om the above-referenced residence. All three bulk s�unples were reportcd as non-dctcct f�r asbest�s (see Appendix A for labor�tory results of bulk samplcs). Vl. Asbextos-Cont�ining Homogeneous Area De�criptions and SAmple Y,ocations Tl�e following sectian contains sampled H11 descripliuns and sample lncations (see the following t�3ble for lucations wherc bulk satnples were collected). Perc;eni-asbcstos content for cach samplc indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following sam�les were cotlected fmm the Sinble- family resiclance �i 42?0 Spruce Way in Vail, Colorado, on May 7, 2008: [� oosiois 4 05/14/2008 �VED 12:28 FAg 9709491541 Homogeneous Area #Ol Material Description: White Plaster w/ Craam Paint; Tan/ ink D aII Material Classification; Surfacing Matesial 1V�at�nial Location: Dawnstairs Living Room Wall at Li ht Switch Materi�l Conditioii: Good Material Quantity: N/A S�tmplc �{; DW-01 Q3 Composition: Non-detcct; Non-deteet lmmediate Recc�mmendation: NONE VII. Recommendations The laboratory results of the potential ACM sampled al 4220 Sprucc Way in Vail, Color�do, indicated that no bulk sainples were reporied as positive for asbest�s. Therefore, n� �ibalcmcnl acliviiies are recommendcd at tlus txme. DSC recommends that when ACM is rc:muved/abated, that anly a C:olorado-lic�nscd Asbestns aUatement eontraetor usuag personnel trained ii� the hundling of ACM be allowed to conduct such activities using appropriate methods (H�I'A-filtered v�tc;uuming, wet cleaning inetliods, respiratnry protection, prvtective c;lolhing, personnel decpntainination, negdlive-air cncloswes, air monitprin�, cta)_ r� oo7io13 05/14/2008 {YED 12:28 FA% 9709491541 APPENDIX A BULK SAMPLE ANALYSYS � oosioi� 05/14/2008 VYED 12:28 FA% 9709491541 p�� I,?e�erva�r� Envircinrrl�nta/, May 8, 20U8 Brandon Sinkbeil DS Consulting, Inc. 10988 E. 116th Ave. tienderson CO 80640 Dear Customer, La6oretory Code: Subcontract Number: Laboratory Report: Project Descriptlon: � ooaioi� I�c� RES NA RE31 b46od-1 �3 4220 Spruce Way Vail, CO ReseNOlrs Envlronmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Envi�onmental matrices by the National voluntary Laboratory Accreditauon Program (NVLAP), Lab Code # 101896 for Transmission �lectron Microscopy (fEM) and Polarized Light MicrosCOpy (PLM) anafysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) anelysis. This laboratory is curreritly proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodclogy as stated in the attached analysis table. The results have been submitted to your office. RE8154504-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservcirs Environmental, Inc. will not discuss eny part of this study with personnel other than those of the client, The �esults desuibed in this report only apply to the samples anafyzed. This report must not be used to daim endorsement of products or analytlCal results by NVLAP vr any agency of the U.S. Govemment, This �eport shell not be reproduced except in full, without written approval from Reservoirs Environment2l, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, r - J . "'• ' .�'��, •. — - .:.::,,,,r_ :..= •..z:_,.aF--•',�-''.;':� ..''.�* --.. ! � � {�. •' � Jeanne Spencer Orr President _,. __...- -. � .-�- - � �-- �� �, �,,,.•- �.� , �<.. ��. •...'r. �'���1 !J Analyst(s): Paul D. LoScalzo Wenlong Liu Paul F. Knappe Rich Wegrryn Michae{ Scales P;303-864-1896 F; 303-477�275 5801 Logan Street, Suite 100 Denver, CO 80216 Page � of 2 1-866-RESI-ENV www. reilab.com RESERVOIRS EKVIRONMENTAL, INC. NVIJ.P Accrediled Lsborab�ry �1 101896 TDH Licenaed Laboralory AF 30-0 I 36 TABLE PLM 6ULK ANALYSIS, PERCENTAGE COMPOSITION 6Y VOLUME RES Job Nurnber_ Client: CIieM Projecl Number 1 P.O.: CIieM Projed Description: Dale Samples Received: Analysis Type: Turnaround: Date Analyzed: RES 154504-1 DS Consulting, Inc. 443 4220 Spruce Way Vail, CO May 8, 2008 PLM, Short Reporl ?A Hour May 8, 2008 Page 2 0( 2 Analysl: RSW en L - � �' on on- Sample 10 Nurnber A Sub �� Asbestos Fibtous Number Y Physical Part I Fibrous Componen E Description (°r6) M�r�ra� ; wsua omponents (%) R � EsWnzte ('X. °k DW 0107 EM 273682 A 1Miite plaster wl cream painl 10 ND 0 100 B Tanlpink drywall 90 ND 10 90 DW Ot02 EM 273683 A Whiie plaster w/ cream painl 75 ND 0 100 B Tan/pink drywall 65 ND 10 90 DW 0103 � EM 273684 A While plaster w! cream painl 50 ND 0 1U0 B Tan/white drywall 5� ND 90 10 N�Non: [kle.led TR�7'ravo� "I�5 �%�uml Estio�us 7teui :�c.=Tca�udilc-Aqinalile NMr Fuuheranal)sis by'ICtiJ is:awramrndal fia c�aii:nlly bxnd malrnal i� c Aoor lilc) if PL�i ces�ha an.l°6. Dala QA O C7� � r � N 0 0 ao r� ty � N N 00 6�e m � 0 m � m � � � r � 0 � O O f+ to 05/14/2008 R'ED 12:29 FA% 9709491541 0 � ! � I� W I � � � SL . C � � � � C � � w � � � �1 � ID � W d � Y � �1 � � V� � Q� � � � 0 � 1 ` 4 i i � I ' 1 ! ' $� � ' ' 1 ! ' � � 1 �� -', �; �� � ' � � + C 1 , � s ( i � ; � �� � ` / J � f ; { .,�. � '{ � „ � �V �{y•' ' '� g � � F 1 , m�-3 „ � � � � � p � U� t 't ���� � f -� �°��`��� •.� �� ! ` � , -� �Q 8 ��� f"' , I , � � i � � � � 3 ?�1 � �v� l 3 ��, .� m - - �.. s siau!a�uo�J {� ` !,. � ° y°ro�� � � � _.....�P�a�ws�lr ' � — -_:i.. � �4 � � � �on��s �� � • � �� � i ;� i T��uo � O� '02l9 'USKB "38J.W 'X31� -S�INV�o --- , ., . � - ------ ----• - -•° - —'': •_r• ue�B ��W ':iwR13 � 'd'pi 's Veraa .,, l. ,. � t I (s�iJ�IWM • g71IL�N . ( . � � r----- � eW�l�db 'Ri�t - 1Sf10 � �.� '�.� �L - � I � __._. ._. . . . _ _. �� _. _ C a�YtD�+K�SI 'a�u�o+�!ri 'w��lwos 'luw� I �, . �'/� o�. i:%w•� u i�� �/►�r�y ' w' 1 i �� x,�na �,ed� e►,� �a�, �s - � . ° ��� � �.k i. � .� z ��� °` a �+p �. ' � , } I:.{ � �� � � � ` � �a• � � � ' � ` �" �'. . � � r I , � �-� s ' ; : -s�r.e �� � � � � � , . _ � 1O � � � 04 � y � � y f , � 41 g, � I � �. o � ��w 4 � � � .� , .i q ��L � ��� � i � � - �I � r 1 I�� � I 1i 1 � z .: �� � ; ; � � !�' � � ¢ e'� � � •; � . , ;��� 1 I 1��= �J r� = s� �' '.I f ► � � �� r � � I.• � ' � � � � � �� � � , �� � ' a 3 3 � `� �.,° ' _ ; �� �� s �� � � $�f�`�� i � ;:.� � i �� �� �� � � w3��,��� �: � �� ,�� �� d� � � ��� ad u� �� O � v� .r�om��� �oiiioi3 � S� � � Z � � .; � g } _ � '� s ?� > e� � z m m � � � � � t Y, !A f � � i �' R � � v a '� �. x } f a � � � 0i' � � � F o � Q �'. �� � S;'u �S � � ^ i�°, ► ° � � L � �; '� n a �� � � £� I v W, W, � F � � �� �g � � , �� � � {... ._ � � •. .,�j,,...s v�' �r�y i.' ; €� .�• . � Z ��� �'�' E �' �y � ; � � R S i z , ; ��� � m m • I , • N C � s�C ; b �• ; ■� . -�-= , � � y � - � � n�� � d� m � O gggn p '� � : m � � ( ,� � ti � ; � �� 4 �a �� .; t � �3� ; : ' � °$ .�'« tl � S. s-^ a ' ; 0• � i � � y' . � i � , ' ; � � e � ;, s i � = �� � v m � � � � '�� r� u � � �� ! f� � i ' � � ' ` � +� � I ��./ ..-,�� � � �V'��{i � I .� �;� � $ _ x w � � da m _. ��,1 c � - . �� � � ��� ��f s� ' I � Y � � , i � _' � n � � ; i ,�! �' .. a�� L�� � ��� $� �T � �J� 05/14/2008 �YED 12:29 FA% 9709491541 APPEI�DIX B CERTIFICATE � oi2ioi3 "�'. 1 05/14/2008 �VED 12:29 FA% 9709491541 l • � r : . ..,�.�r �% 1. r' �� J� H'. t�i Pl1��' �'1 �~ s'�.�� p� ��i i�� 1! � 1J L i( �.�L� V � ���'^� S �.� _��M,,+�,qy�x.4��� • '�' " � ' '4 JJ � � r �-•�i' SM1 y � r� oi3iol� ""�-.^ •-. �`r >. i q4� 19r_ `' . �xC�!a�:.Y� .4�� 1 �x �.;� ';�; 1�SB��'�'Q� `� �`�; �? �=.:V, ,: � r. ti` .::��;,-,'� �-s � ��,;, � .� ,, ,�,: ���2�`Y�'��A.T�OI�T� � �:�.��f `� `�-��� ��, � �..�� r e� � :�:1�w:�;,':-" a �? A4 1'=,' r `^ ` ^_`''�'..�.'"b�f ,t � >, � ' "' ` � y Caior3do Deparnue�i of PuU�ic F��a�cE� �,� �� r, ,��� �ti 3 '�; .'. , �; , , r a[2d �AviY'orunc;ElL �• `'x� � x `�: �1 l�.�r Paliv#ian �vnvQJ 'p�'vision ��' ' '��s�. � n�,, �i � ,�h �^,: ;:•� ,;,�ax� x. r � `'�;•' � {� _.7s 1 � ' " ��� ° �"S:L �, . e 5 ihi3 CCi't1�S'•S ��at :�« ^+�'�� s ;� '� -� .�<, '��:'+r" , •• ;�� ��;�,: � " �k` �rar�d�u 5�nkbe� '�f�� �;��'� �4 ' ��,� 1 e��i 1 . i ;,f' N' �Nr y, ��4; ��'CIIfI `ui�10n �Q; ,��4� � ��':}'• a'�.1' �'. .W "� `^ wL� � ,�%�?,�,l�Z �! i r>� 1 �':�yY �1 �i�:,l' � �Y � JJ' ,�w• �`� 83�s mc:[ Th� z�'�c}uiresnents o�2�-7-50� C�.R.�. and �ir Qu��it}� �ontrol %��' '�� %��,, h': a � ,- �: � � r: ��: �� �Cr�mrreis�ion R.�gulation No_ 8, P�tt II, and is hwz:�)�� cc�r�-tit�r�d b�• the `'�` �>"�'S � � '�'� � �'vt , P v'�� ^; sr�te at�CO�Ot�� in, �kie to��o��'ing'$is�cipii�e: '��w �i� ,.,. > , �, �„ f. �, ,�"w �r:;�yr� ,� i, + �' ��^N.�I��� �1� � � 1 , � �yy qs pn I � V'Sw S P' �6+ i?'- S � ;,�` � �ui�din� In s��ec�or� �' ' ., �� ��:.' ; < . �; �, r •, , .+r�R}�, � ;:•{+•:�°i . , � '} ,`••��,� '����;a,r�J '•;`�`�, LSSi1��: .''�%lissipU7 ,� •;;r,� �� ;,{� ,-:��.,, •;� .,, :�, ,,� ��;` �xpirrti nn: Si�,Gl�4)4� �� �_}�� • <�� r a�;�,��-1r � S; / �'`` - '�:^�•, .. �;: .�w r�) '�` �~�i ��M �'1 �,-p�, titiS'4 �st�'�%'S \ ,��'�'.Yi'', �•'•r�� Sri a�.y t'i�� 1',��_ � 1 � �; '� ,A?CD Fteryecscr��rt y:';'�5, ' ��.��� I •` �' ' b4'n�. !! '�� 'T�1�f, ��:.�'�,��� r�f' ry � � M� ll�� {� ' .;!: �1`�&[eflif4.wrOtWii�anly>f+t�rrbcps+sl,Y.6�uA,�ACXHChii7liv��i�,P+�W�l+��'Xw�,•�v�+Irtr • '•',„,.' `. � •1 � �• � rY � r, �:;�t�t. % h� c�rnPfre�aflne iA fir df+tiv�GaC vpeer�ir�lul�tlr� Y-�;�:'�-K �� '' i �'-�.'jti�-%'�%K.� �: �(�t{ •��.:��°��..... � � .• �J,'i r � � `.., i i ,�iSrn.:.�� � ��;; ,,. ,, : ti •: .•r . ."{ �: .'•}';�SSi:,. - . , .'-r . � ..tif • ,!�:•, y i e , �: Ji ;� "^i. t . , , �e. ' F �' �k: ' �. . r Y " ',� �.,L �;;,,,,�,.,'ti-.y� • �f f'�t)„��L'��J I rvd:� nA��.v��, �'•:� �^J /'i.� ,�"�./Y f�J'. �i� wg'r. ��i:;�. �'. ,a����J.�'���� � •'��=,�y4 �ff�%�r , ! yi� a� �i ,,> •� • i� \ / N�' � �� I, ,� r�' • � , y �,Y ���,� .. i 1 � ��i�'°'y � � i� . r', � ' }• j` � `Q� ✓: i '�r !�'' \ J � i Y��. A�� 11♦ !,�'� /' f�J�J� 1 `\r� ���q� �,�,�� �y.�';� �� .�,�� a� ti •;"1;1� ��yiy z�;r�' ' �.r� � � r 1+�: ,�?�:� �✓� '�'� ,rr / • •�; �IT'- �ry, � �Ir � i J ��q�v: . •'ii p K• ( rI� ! ,• }.� •,► ��, � J� � � ��+4:. � 4 � ^,�w"�+. .��4'�^• ^ =-,�,.�t'..L_ ' .+'.�r`, r �.'Or�,.� =�". .�'�a''k`e . ��_ _ 'f'• • _ _ ��'`, rt::.�� o�. 9 ,, -�� �� �` ' � � Diepartment of Community Oeve%pment Bui/ding Safety and Insp�ection Services 755outh Frontage Road �ai/, Co%rado 81657 970-479 2138 FAX 970-479-2452 www, vai/gov.com BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS: TO: FAX/Email #: Contractor/Appl icant C&H Construction rich@candhcon.com NUMBER OF PAGES: FROM: DATE: BUILDING PERMIT #: OWNERS NAME: SITE ADDRESS: OCCUPANCY GROUP: TYPE OF CONSTRUCTION: NUMBER OF STORIES: BUILDING AREA: Architect VAG proj# 949-8134 John Plano, Building Plans Examiner 05/22/2008 608-0130 Goldman 4220 Spruce Way single family VB The documents submitted for this project have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 International Mechanical Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code, 2003 International Energy Conservation Code and 2005 National Electrical Code as modified and adopted by the Town of Vail. The fo/%wing comments wi// nee�d to be addresscd p�io� tn issuancae ofa bui/ding permit; For processing: • Please submit four com�lete sets of revised construction documents containing the requested information with all nlan revision items clouded or otherwise identified Partial plan sets or loose plan sheets are not accepted. . Please respond in writing to each comment by marking the attached list or creatina a response letter. Indicate which plan sheet, detail, specification, or calculation shows the requested information. Please send revisions to the attention of the plans examiner with the building permit ap�lication number noted. • Please be sure to include on the resubmittal the engineer's or architecYs'�wet" stamp, signature registration number and date on the cover page of anv structural calculations, all structural details and structural sheets of the plans. For commercial or multi-famil�projects all sheets of the plans must be stamped. s �,; Architectural Comments: � Please provide clear floor plans for all levels of the existing home. It is very difficult to determine exactly what is old and what is new. (IRC R106) �There are 2 sets of architectural drawings in each set. All the architectural drawings are marked "Preliminary: not for construction" Please coordinate the submittal, remove all duplicate sheets and remove the °Preliminary: not for construction" notes. (IRC R106) �Please have the structural engineer verify that the decks have been designed to 100 psf live load. �Provide a ResCheck report. Change the plans so the r-values on the plans are coinciding with the report. (IRC Chapter 11) � Please provide details to maintain roof ventilation. (IRC R806) '� Please provide adequate detail to verify that minimum ceiling height is obtained in the new powder room # 105. (IRC R305.1) V7' Please verify that the old fireplace being re-located to the bedroom is direct vented. 8 The shroud proposed for the fireplace terminations are to be listed by the manufacturer of th fireplaces. (IRC G2427.6.5.1) --- C�Q '� �-- C-�S�T�� ` � �� � � ���-� �2.2 — This sheet indicates the door between the garage and house swinging over steps. Please change the door swing. (IRC R311.5.4) �0 A2.3 — The floor plan of New GS #2 Bath does not scale 30" wide in the clear for the water closet. Please show on the drawings this dimension is maintained. (IRC R307) ]�,1�S1.1— The new roof rafters between grid E and D are shown through the fireplace chimney. There appears to be no room for the flue. Please check this and change the drawings to accommodate the flue pipes. Please refer to the cover sheet for information on resubmitting plans. in order to avoid delays in issuance of a permit, please check �1 requested information is included with the resubmitted plans. Please submit revised plans as a complete set. Partial plan resubmittals will not be reviewed. John Plano I.C.C. Plans Examiner Town of Vail Building Safety and Inspection Services 970.479.2140 jplano@vailgov.com F•\cdev\CHRIS\PERMIT COMMENI'S\608-0130\BOS-0130.DOC Memo : Project Name: Goldman/Cheney Addition Date: June 5, 2008 RE: Building Permit application B08-0130 FROM: Janue Hunt TO: John Plauo CC: 5cott Goldmau aud Maryalice Cheney C&H Construction Anne Gunion Remarks: Jolui, � �� V1�g, II1C. Architects & Planners Projec3ENo: 2723.00 VAg, Inc. Architects and Plamiers Town of Vail Building Safety and Inspection Services BelowLplease find the our responses toyour review conunents dated 5/22/2008 All notes reference drawinQS Issue ASI #2: 06.02.08, Issue "J" attached. 1. Please provide clear floar vlans for all levels of the existing home� Please refer to sheets X2.1-X4.1 fur existing floor plans elevations building sectious and details. 2. All architectural drawui�s are marked "Preliminar� not for constiuction"• Stamp has been removed from all drawinQS Sheets X2 1-X4 1 sliow existin� buildin� conditions sl�eets A21-A4.2 sl�ow all proposed work. Please see le end and notes for walls to be demo-ed new walls, new windows and new roofs. 3. Please have structural eu�iueer verifv deck designed to 100 psf live load: Refer to sheets 51.0 and S1.1_ 4. Provide REScheck report• See attaclied Coiupliauce CertiGcate 5. Provide details to maintain roof ventilation• Refer to slieets A2 4 and A4 1 for notes calline out sl�ed roof ventilation requirements. 6. Verifv minimum ceiling heiQht is obtained in the uew powder room #105: Refer to attached SK.O1 and SK.02 for section at new lower level powder roonr area below 7'- 0" indicated as "low heiQht" on floor plan. 7. Verifv that relocated fireplace is direct vented• Per X4 1 fireplace is a Heat-N-Glo GL 6000, See attached s�ieciftcations for direct vent information. 8. Slu�oud provosed for the fireplace ternunations� Tlie prouosed sl�roud lias been eliminated. 9. Chan�e the door swinQ between the maiu house and Qara�e• Refer to sheet A2.2 for cl►a��ged door s�ving. 10. Maintain 30" clear dimension at the water closet in GS #2: Refer to sheet A2.3. 30" clearance is dimeusioned from face of glass sl�ower enclosure to ed�e of vauitv countertou. 11. The new roof rafters betweeu �rid E and D are shown tluouQh the fireplace chinuiev: Refer to sheet 51.1 for sh-uctural change. Pirysical Address: (970) 949-7034 Nlailing Address: 90 Benchmark Rd., Suite 202 fax: (970) 949-8134 P.O. Box 173a A�on,CO 81G20 emaiL general�i!vagarchitects.com VaiI,CO 3165R-173=1 . !��- _�:. -'�_�-,. �. l =;'(; �,�'� t,,�1ry,ri¢�...�w..,,,t, '�, 5�nh ,,��, t: �., �. ���s'��1•��;;;�'N1 Y ''�''F11i113`II .If `�f� �u;Ill �'t�i111II '� � �tdl�.Ij��1 a�� ��.�,�'�I F��f�.1��,:��i���t��'���c •�arimFntc11`c;i,�r'f!r`�tr.,,��,',; �',:�����l:;:f�tt��i'�t !CIll7[j �il%ti���' �71i("� l.�'!ii:�{��;'I'i�L4'? �c,iri;li.�.> .�4�U�1�,1 {i /,:;flj .?S� I' F)i:lclir:i� ��� �/lit?;`c�L.�C; .. i;i �r ,%'.`�/��".�1.?i;' i( C��'(]., �?t,''=,?�1 ! ,_ �'Y7r Kcli:i;0l�.�::,)71�1 i :�. . . � . � � hlC.i".f��t�V�Ar �i���'..�.��I J�i�`l► C'�'r�s��:'�i:�?��.,��I��"���_�,.�:,!',`ia,{tlef.. �._I_�{� �'�.�'�I.�...'y���.��_�....'.��.'� 4 si'!,{'�1�cz3I1.;��; �.^__........�.,,. ,�..., — - � '1����:R 4��'r,lii; I'i� : ,, ±::!,ill f i i:;'si;,�'i il"f �,,�.11,i I%;i ii:�1 (,.:����'1 �,('?':'I�ys'�'�.f�;::i't7 `! , l � �l �1ff.�� I'�! !(�li (! (, ''i_I�i i.�t�'ih��d_4=t. �%.i�.' RI�t��ti:i�ll:;Ya��. �E.�� �'��' s��`E; �; .�.SF_.�� i �`H'4;^ l�h���!t�k.i����.n X 'f+ u �IW �C��:i�.�i� Y�.'�FA�,Y.9�'�i�C.. �,��� /�4�°.,�t,�`f'F��i�;:�r�� GN��„�;ti'�,�'!i!' .y�r ����.i�,� a�.i��;'+ � ?(��; ��� �. �.`ia�k, �ii',+,.I,�!t I f.��:)��:I: y+�� �, �JI � �f . ��� � �' 1��6'k Li� 4..�-. 1.. .,Fa'� ',T i�i�.��' �.,,fl. i:;�",7�i ��,�..cy�r���,: t��,��;�:,��F,; �. • I � ai'kc'.�:;t '. :i'.°+ 1': � �. ::;. C.:.f:� i:i.?..`,.� i��i'!1 i'I':.li', i�t:frl �i!"�i,) �"�7'! �,:'.!�..)1'i'IiilE::r. ,� j `; r ; ,',' "? i ' `, ,; � '�t�}�:��i_;:!. :s' � 5..� : 5�.1' i� 7,. I'�. .:i�,.,;7„ ::�i ..... tiJ'.';:t'3/ 4 , q�� ,i�` ry� . k ;' : ��; :, �i, f ..• ,� ,.��_ . r. [:.� ;.ii:�.�rii�l���; 1`t;�ri��;<�, p F �:�i'�� a .1 � It ��t1 y`1�`.Iil�l�ili �j t�.�'�.��lt �I.l�l.l}�.����',I����I` 1 a [ � ( � � ,f-_ C��, .i.1t I 9 � - Ct'r1��3•'.7f�1 I.II I i`. ��F �1l it j� IJ�.;(?� [i i� M'� 11 � t. i�t �� � �� �>� � � i �3� '�1 �� �� � i E( ts �+, If . '� � {i.�l I��_ i;j� ?�i� �J� SR.I 1,� Ili�'�i��li� �; 4,.�� ��.t3:i� If�C- ft3) � i'�f� �,' ���r;i ��l'�' ��3� ��~Gti � t�,��kS C��;''iIl 1.�i'�fi i "C,�� {,lli.tC:'\1t5�IS;lI �..'.�4�k: Clfl,� �.:�•�1�;� ��liJf:l{;?.�.i ,.�' �.'.i1`.. _�!�:i Ili4t{, �i.':� .. li., ...i.. IE,�.h,l �(;ti 1.(.:,` i�[)�'�?i'1 �<< 1E'I . . , ii�- �' � .� + i' i�� � �a t I��i'� i.dfe i� .`i�'�:'F 6" ��ceE�l'��;i��: , � � , ..,,�, �� r �� � �+� � j � � � ' .�� ��� , ����,: � � �.SE:� a, , �.a�,f�� :kr, �:.,.:,�, .�,.: �:r:;'�� i`�� ���fP'c, i� r.,°�;�;� .�; r.,i r1 � E,�.. .r �;,..r t s.�„i.r t�. �;.� ;:9 i.c �. . � R �� �, i : r� � �'��� ���� <�s� ,�i')(il�f �i1t1 ��, �,� , � � � � ; ���' i� �Ir, ����� a�t E� �i��ii�� ���� ���f E;sii� `��'! � _ fl'I))It I. aF � � I , id1�J;ilv itt�)E11ill�li cI�3,.G.�i,_`I (l 5i1,aI� j� iy!�I�l i�. t�11' �`....�i .r, �i7' �i <G�ififrxj ���r�iE 44i'1,� ����1� i„"�< <�....�Si�y � �._..,..., .�... .._� .__._ ... , ....._... .... . , .. f4wNT rt. .�76�4h1� �.i��l�,i{,:'��:a i.1tP� �(I1 ��It?�I �.:N��9y�'�. r�''I�.-, �,�t��.il��l it, i�i 1���� ia � .� . .. �....:{ � -� �� ���t� � �f..Fjj��� (!_, � F� 1 (_I �.t....f��l{�Gd �. ir�r-II�� s.tL .t �il { Cl cl ( 1(311 _ �- �...f..7i �...{4.�1f il��i 'u'qf` 1 i� I�<h1 i E � ��r. i tiF. :r�� �.. ,�..'{ (! ?�ra i i, �f7`�.:�.:,�,'�r` if�r,,-s !� �'..%�iz.°s 1 . � . . ..�. . .i ..____ ._.. ._. ..�. . • j'- +'; <.� �rca „' � � � � �, {i �i�ii� ffl(Iri�� �4���,ti{'... �,I{t:�l!':�.� �. ttt;.�� �, i, t , 11� �� y , :t7C1 �R �.� i ���, � , + : �'� .F.... ..... ..r.. _._ �S . .. .. . n .......,..�..r.�, .... .,......, _ ._ _ _. _ . .. _, ...., , �... _._. , i. �,�.-r�i' f:������ � I ;a � .��;rnL�e��. �:��:� :;1�.�. ��Ii�.�..t.A� I� �.�.... �'I �.!..'�'' ...II_,,���il�'� E..'�� 4�I_� 1 .71JIi�'�i-1 �� I�f.'�':. �.�a�!.'.,.�`�:....'...�1 � .� 11��t�:. ( .1Y1Ltl�lil...`I� FI .��r ll����14���.t�.�'�f. t�, I, I It i,i fl it!lf i �1'.'1 �� 31,+� + I+ �j1it" { 1 � P�" , �� f tfl: `?it�I;tI�T t'.y Il� !<1i.1+)f�4�� ��� �f !!'S11 3� , , i i ,._ . , ., _ 1 (�C.;'j{� e:ii��� �'i�'1', ia�� t�1� Ei'' (1' ifI' kb' ft!' !;. I� i'1a f i!,i�!A(li i.1,(,-�a illli}�,.��_�.�.�'..�....1 Cj ..-LI� i1`{J,A.Ii' . _._._ . , __ ' . . ,.... .... ..... . ......... _ . 1}'�. �y ,i � `�'��`;�. .'. .. �,.�-'�E�''':�-`. � Report Date: 06/05108 Energy Code: Location: Construction Type: Glazing Area Percentage: Heating Degree Days: Construction Site: Generated by REScheck-Web Sofitware Compliance Certificate 2003 IECC Vail, Colorado Single Family 19% 9248 Owner/Agent: Compliance: 0.3% Better Than Code Maximum UA: 334 Your UA: 333 Wall 1: Wood Frame, 16in. o.c. Window 1: Wood Frame, 2 Pane w/ Low-E Door 1: Solid Door 2: Glass Floor1: All-Wood JoisUTruss Over Uncond. Space Ceiling 1: Flat or 5cissor Truss Ceiling 2: Cathedral Furnace 1: Forced Hot Air (Non-Electric)84 AFUE Boiler 1: Gas-Fired Steam75 AFUE Designer/Contractor: 1980 19.0 0.0 93 350 0.350 122 41 0.350 14 34 0.350 12 1489 39.0 0.0 39 580 30.0 0.0 20 982 30.0 0.0 33 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been design d to meet the 2003 IECC requirements in REScheck-Web and to comply with the mandatory requirements listed in the REScheck I pectio Checklist. �' � �' -- ►� �' ��� �,i. D � � � Name - Title a ure Date Project Title: Data Filename: Report date: 06I05/08 Page t of 4 r Generated by REScheck-Web Software Inspection Checklist Date: 06/05/08 Ceilings: ❑ Ceiling 1: Flat or Scissor Truss, R-3U.0 cavity insulation Comments: ❑ Ceiling 2: Cathedral, R-30.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1: Wood Frame, 16in. o.c., R-19.0 cavity insulation Comments: Windows: ❑ Window 1: Wood Frame, 2 Pane w( Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1: Solid, U-factor: 0.350 Comments: ❑ Door 2: Giass, U-factor: 0.350 Comments: Floors: ❑ Floor1: All-Wood Joist/Truss Over Uncond. Space, R-39.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Furnace 1: Forced Hot Air (Non-Electric): 84 AFUE or higher Make and Model Number: ❑ Boiler 1: Gas-Fired Steam: 75 AFUE or higher Make and Model Number: Air Leakage: � Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. � Recessed lights are 1) Type IC rated, or 2) instalied inside an appropriate air-tight assembly with a 0.5" ciearance from combustible materials. If non-IC rated, fixtures are installed with a 3" clearance from insulation. Skylights: � Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19. Vapor Retarder: � Installed on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: � Materials and equipment are installed in accordance with the manufacturer's installation instructions. � Materials and equipment are identified so that compliance can be determined. � Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. Project Title: Report date: 06/05/OS Data filename: Page 2 of 4 � Insulation R-values, glazing U-factors, and heating equipment efficiency are clearly marked on the buiiding plans or specifications. 0 Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insufated, and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: � Supply ducts in unconditioned attics or outside the building are insulated to at least R-11. � Return ducts in unconditioned attics or outside the building are insulated to at least R-6. � Supply ducts in unconditioned spaces are insulated to at least R-11. � Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return d�cts in basements. � Where exterior walls are used as plenums, the wall is insulated to at least R-11. Duct Construction: � Duct connections to flanges of air distribution system equipment are sealed and mechanically fastened. � All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics are rated UL 181A or UL 181 B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). � The HVAC system provides a means for balancing air and water systems. Temperature Controls: � Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is provided. Service Water Heating: � Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is paR of a circulating system. � Circulating hot water pipes are insulated to the levels in Tabie 1. Circulating Hot Water Systems: � Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: � All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depietable sources. Pool pumps have a time clock. Neating and Cooling Piping Insulation: � HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the leveis in Table 2. Project Title: Report date: 06/05/08 Data filename: Page 3 of 4 Table 1: Mini►num Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" Temperature (°F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 Low Temperature 106-200 0.5 Steam Condensate (for feed water) Any 1.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 Brine Below 40 1.0 NOTES TO FIELD: (Building Department Use Only) Project Title: Data filename: 1.5 1.5 1.0 1.0 1.0 1.5 0.5 0.75 1.0 1.5 2.0 1.5 2.0 1.0 1.5 Report date: 06/05I08 Page 4 of 4 .ea = — � VAg, Inc. ,\rchitects & Planners Pusl Office Box 1771 \'ail CU 81658.173J (970) Y49.7034 f:u:(970)949.8134 �ni1:4��ncr:il:ii �n4a�'chileil�.ir�i�� e911 fleneliinark Rond Suile ?02 reo�EC r Na,n�e: Goldman/Cheney 4220 Spruce Way DIL1\VING TI"1'LE: Section at I'owdei• crai F• in�, _ �,_��„ Addition Room Entry PROJEC'T NO: 2723.00 �ccuw n��rw�� n� n� n PHASE: Permil st�eE r: Sk.02 I)4'. \7� m _ - ` � — — = � � — VAg, Inc. ,\rchilccts & Planners r�:� om�� e�. iu� \'nil CU 81658.173J (970) 949.7034 „11 CI� 4i (970) 949h8134 "1" vn x.•�.�u���..k e�.a s�da� za: PROJECT NAIUE: Goldmaii/Cheney 4220 Spruce Way ua,����iNC rrri.e: SCCil011 �it i�01'VCiei' G('11.F'• 1/1" = I'-II' Addition IZOOIlI ll001' PROJECT NO: 2723.00 ICC114' Il �-I'G. 11l. Ill 1\fl PH.45E: Pennit sHEer: Sk.01 uc. �ii t' �i,49? .. 5'F ., � � � S . ' ';f. '.� � ly .'? � d �� k �x r @r ' � � .:��..,;:� . . � � t HEAT� `GLO No one builds a better fire ��N�" it � �= s� �i:- � ' �� ;C: � 4 � �� � �Y���' i � ,�„��� �r `� �� �- �� �,�,,.�.�_.. �° �� � j�� ?.: '�, �' �.' .. . . . . . . �'.<� .., � f. t_ __W� � � � .. , , � r'� � � ��p��:� :���. �� �.� ���. � � �.� � �_ .� �._� � �� � � �� ��.:�`� � The 6000 Series is loaded with state-of=the-art, patented innovations. ���� �� �� `��i�♦ �, �..�,.w ;.��;� :s:,=, �' --°.� •_ �; .. . """ `� �� : y� Flame-Out-of-Log Technology {y; Adds auotlier buruer iuside of the lo�,�, prociding a niore realistic flaiiie -'' appearance aud better tlame height. ,.� Mystifire Burner �� Coucealed, inulti-level, te�tured burner uiolded directly iuto the hearti� �•�� refractory. Improves flame height, eliminates meta] burner, and best replicates a woodburning ash bed. r� Accent Lighting �„ � Adds year-round aiubieuce �vith ot ��itliout tlie fire. IntelliSwitch Controls ��� User-friendly controls let you operate fireplace functions �vithout going underneath the tireplace. Our advanced technologies let us create dif�erent flame "ages" and looks. A younger fire ��ch y�ell��� Elames concentrated in the center of dic boa witli lrss glv�v 6000G and 6000GCF MVstiGrc burner and 30,000 13tu/Houc input A maturing fire ��•�rh spreading flames, plus more glo�v on tk�c lo�s and embers 6000GL Single Flame-Out-of-Log burner plus Mystifire Uuriier and 30,000 l3tu/Hour input Heat-Zone ° Optioual I Ieat-Zoiie cli�nate coiitrol systeiii turus your tireplace into a Ilexible, euergy-savitig lieat source by traiis£erriiig excess l�eat fiom your fireplace to otlier locations in your home. Not available on 6000GCF. Heat Duct Optioual I Icat Duct svstem iinproves fucuace rfl�iciency aud roun� comfort by piilliug excess he�a[ a�vay trom the� titeplace, out of the hearth room and into y-our fiarnace's cold air return iiucting. Not available on 6000GCF. Limited Lifetime Warranty* The �tron�es[ in the industcy. F-Ieat �� Clo pcovides a lifetime �varraut�� on tlie u�ost importa��t aspects of the fireylace: tiber lo�s, titainless steel bttrner, t3rebot and hcat exchan�;er. IntelliFireT"' Our e�cl�isive, state-of-the-ert [utelliFire ignition s}�stem redures ;,cis consuniption and theti�iog�uerator �nrear b}' prbviding a pilot Aame nnly' ���hen ner.dcii Ako su��plies a haiknp batter}' systcn� t�� ran tl�ic tireplace during a po�n-er uuta�e_ I .. ..;i , _;i- . _ _ I ,,.. ii � • o„ A very mature fire, blending larger flaines witli ]ots t�f glo�v spread tl�roughout the fireUox 6000GLX Dual Flame-Ou[-of-Log burners, Mystifire burner and 4(1,U0() Btii/Hour inpilt Healthy Hearth Our direct veu.t hreplaces featuce a sealed combustiou chau�ber that draws in fresh air fiont outcloors ancl discards all ro�nbustiou by-piroducts back outside. Recognized by the America�� Lung Association`-' Health House" program as a Clean Air Choice.'" Direct Venting System CONVEGTIVE HEAT Rp�IANt NE�T oNVECTION ., CAININtANE � . ,�„- _� OUtS10E W1LL "���':\ EXNRUST O:S OUTSIOE AIR fOR LOMBUSTION lLOWEP AMERICAN ' LUNG ' ASSOCIATION NEALTH HOUSE . � � • • - • _. . . _ . __ _ _ . . __ _ , MODEL ' HEIGHT FRONT WIDTH j BACK WIDTH � DEPTH GLASS SIZE '; Btu/Hour Input _ _. __ ; _ _ 6000GLX ��tual Frairing v.ctual Frar+i^r� Y._tu� Fran no Actu=1 Frarning 1 6000GLX 18,700-40,000 6000GL 38 i 38-1/2 41 42 36 x 24-3/4 6000GL 19,000-30,000 6000G ! Zg'��z , 4Z ' Z�"��z ; 22 ' � 6000G 18,200-30,000 - s, �. �t29J� � 3&l18 ��, �tmaj . . zo-vn '.• .. '. �524) ��. ��. � . i�-ir� - �aar� 'i ' i . v , � �i,,All � n �ier3� �a ��ul .. ♦, � 6000GLX .� +rs I�+t 6000GL 6000G 6000G Top View Corner Installation 6000G Top View - za-irz► pzz� '. u-1N I��l . � 2t�7rz 1 � : j ���� �.. _ . _ .� f t �&�re � j1A37) 42-1V�<. , (7P85) ��.. . s�,�n � � �s9c� . n` ��n [zi2� { ; ;(jz . _ .. , . y� � 1,,.� ♦ IB'� -� ��asz� �o �ims� :� . GAS LlNE . , .. B 11-518 AGCE55 ���,. �2D2j ..�.. 32-1/8 -�+� �291j , Ie 15� l :�'.1 � .:� _+ lt : ": �� , � � �s �e ► � I aa•_ua � � Side View j5ges� t.� 2�tre ��� � jsai� p'i le�s� �..? ! ze-na ��� t ) a�-in (sa31 �' 1 1,�-*-�it Y. k I$52j � �� . t �� ! � � ° ;�_ , � �, ���. 3 i :'� . 3Gt/8�. � fi•718 ► i� 1 � j916� 2-3l8 �. (t7e� Iz�l '.. 4t � fe�l + j�2� (t0e3� Front View 6000G Top View Corner Installation, Top Vent 1 Framing �e-�n �s�e� 7 . �z � lioer�. � 23 Side View ,- 155s� ELECTiCAL qCCES3 k MODEL l i HEIGHT ��FRONT'WIDTH 1 BACK WIDTH ! DEPTH j GLASS SIZE Bku/HourLLinput i � Nctual � Framing � ��� �c-tual E F2mirrJ � Arhial j k , Adual Fiamirq Framina ' ` 6000GCF z - � ' i � ` , 36 x 24-3/4 ; 20,000-30,000 � ; V 38 ! 44-3/4 � 41-1/8 42 � 28-1/2 42 � 21-1/2 22 � , _ �-- 40 I I1014) 20-51B I5251 Top View Corner Installation 16-3/8 -- - [415] _ �� � �;� / � � �� � ; �` % '�\ / ; 72 ' R �1832] 36-1/76 ; [916] ; ' '�'� �`� � i 1/2 ►.,�_ [14j � w�,,�i � � I Side Vieti^r 38 � [965] i - 2-1/B � i ��� �_ —_�_ - �i� l� � 6-7/8 - �_ � ��75� �`-GAS LINE ACCESS Top View .� 2e-vz ��22� �34�-� �4 - i i - I � o % ��' 21-1l2 o I`�8] �� �r �`'� B � - 12-7/8 � [203j j329] ►+ 32-7/4 '� [820j � i ; --� e� k � - 44-3l4 ��' � [1135) 21-1l2 :; i i �sa�� I j � I iF� 36-1/B -►'j L 7 (917.5] I (177] '�- 41-1/8 -►^ (1045j Front biew 4 j1 Framinq ,�' 22 'r [559] ��ELECTRICAL- � � ACCESS ` � 48-1l2 �`,; � [1230] 2-1/4 - Mj �5a, � �� I __;�� �:.� _s I—, � ��, -► !+- 5 [128J Side view I io�e 6, minin-�um ver_ical �;ent rwi r2qiihAd p.��ensiors eGoc� are in u;chvs. �elNrer�ce dimersions ���'1;�. `!d� recommei �d m�asu�u.� IndiviJ�d! units ai inslallation. -. �surn=- [na use of I; 2 dr,��n�all. NOTE on �usti�le :�alei ial ;hould n.�[ be Ins4,lied o��er the f� ce. Ma�? sure you do NOl cover tne decorati�.e door openlna. ?� -� �nst- I:dtior iranual fur U��_ai!ed speci I_ations on �install�.�q tl:is prc J i�t. I-'e�t & Glo ras �ve� tl-i_ r.ght to upd e � uts � t�� �.1i al�, R. I�in 3i J- n'iber �,�;iedranca rnay �, �, F,.:;eo _n .I-�e. tyt>e ��t fual b irr?d and th.A ventir.9 ror' c?.ir� 1 �,i� .ised P.d.ur�s in Lh�s l,rnch._ire <�re nol a Irue r�pr�,Ar.t.allo.� :�f 11ie f� ,���,i._ .�n�l, f�..an,�?,. c �l us it: �eu � FEATUR�S 6000GLX 6000G1 6000G 6000GCF our npu 4o,U00-18,700 30,000-19,000 Ignition System IntelliFire"' IntelliFire Flame-Out-of-Log Technology" A.djustable X Mystifire Burner X x ACCent Lighting' Adustable O{�tional Included Cont►ols" IntelliSwitch�00 Optional 4-Piece Brick Refractory Kit Stratford or Schoul House r�a Red 3-Piece Brick Refrectory Kit Nq strarford or School Hnuse Red AFUE Rated (Ceramic Glass) X Nq , , . _., . . ,.. Heater Rated X � Fan Kit w/Speed Control X Optional Heat-Zone' Option X X Heat Duct Option X X Gas Flex Connector X ;� ' Requires the IntelliSwitch30� to operat� F9afiie-0ut-i •• Remote control aqd other wall switches available. R � Surrounds Parsons � SecUon B-B —7- Section A-A ' s ii. � e r6 ]/� L r � B 1/2 �]9 3/B� � �� L , „z � „zr . �, 53 . 39 1/2 ` � 1� 1 3 I e e 5 v2 1 Portico SecLion B-B 3 ) 8 1/2� � Section A-A T 9 1 1/2� 4 3Q000-18,200 30,000-13200 intelliFire or Standing Pilot IntelliFire NA NA x X N4 NA OnjOff RucF;er Switch on Unit (uptional) Optienal NA NA Optienal Stratfurd (Schooi House Red optional) NA Nq X . _ X Optional Optional X NA X NA X x �; �,_ �. � �t. .`. Sonoma eclion B-B l 2 ) B 1/2 �1 5/B Section A-A 1/� L z �,ar 3 H EAT; ° G LO. For complete information and valuable assistance on this series, please contact us at: Heat & Glo A brand of Hearth & Nome Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 (888) 427-3973 (952) 985-6000 Emaii: infora�heatnylo.com Web: heatnglo.com TOWN OF VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-213 5 Job Address: Location.....: Parcel No...: Project No : OWNER APPLICANT CONTRACTOR VAIL FIRE DEPARTMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT 4220 SPRUCE WAY VAIL 210112226001 GOLDMAN, SCOTT M. 26 SUMMIT ST PHILADELPHIA PA 19118 VAIL ELECTRONICS, PO BOX 3940 AVON CO 81620 License: 198-S VAIL ELECTRONICS, PO BOX 3940 AVON CO 81620 License: 198-5 - CHENEY, 10/22/2008 LTD LTD Permit #: A08-0091 �� U�3U �r i�30� -C��Z.o� Status . . . : ISSUED Applied . . : 10/22/2008 Issued . . . 10/30/2008 Expires . .: 04/28/2009 10/22/2008 Phone: 970-827-9120 10/22/2008 Phone: 970-827-9120 Desciption: FIRE ALARM SYSTEM FOR REMODEL Valuation: $1,800.00 sr*+*s*ss**s*****s*�+sss�sa*a*ss***s*sss*:�*sssa*****s*s*ts*ss****** FEE SUMMARY +****+�*�a*s+*s******ss���+ss#s******sssss:*ss�sss*asts�sasa Electrical-------> $ 0. 0 o Total Calculated Fees--> $ 2 9 9. 5 0 DRB Fee----> $ o. o o Additional Fees-------> S o. o 0 Investigation--> $ o. o o Total Permit Fee------> $ 2 9 9. 5 0 W ill Call-------> $ 0. 0 0 Payments------------> $ 2 9 9. 5 0 TOTAL FEES—> $299. 50 BALANCE DUE-------> $0 . 00 f#i4i##i*t#i###t#fii#k#t###**i####t#####t4i4►###4#+k#*#R##ft####*######R#ft######*##*#t#i##t*##*R*#*#*t#t####*#i##*##tit#ti#*#ftt##f4k#�*i#t#t##ff Approvals: Item: 05600 FIRE DEPARTMENT 10/27/2008 drhoades Action: AP #tff##########►###f#TRt#k##t#####4#t#fRi###�##t###*##tfttf#*t**###+F####f###########f###R�F#*########t####►#*#t##*#tt###########f#f*t*#t�#t#+ttf!#�Fi CONDITIONS OF APPROVAL #*t#4#t##ti#4#�*tttR##*##t##f#####*#i*#t#t#4##fif#t#######4#F######*#�1##fi�tR#�4####*##t#t#t#tM�#�#t#####M#�Ft#*R#t###�t#�FR*#*#i#####4f#�F#####4+�Rf#f DECLARATIONS ' I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, �I and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all I' Town ordinances and state laws, and to build this structure according to the tow zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinanc o e To�plicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOURS IN A�AN�nB���F� _ - - FROM 8:00 AM - 5 PM. OR CONTRACTOR FOR HIMSELF AND OWNER *********************�***********************************�************************�**�****** TOWN OF VAIL, COLORADO Statement +*�***�******�**********�*************+*r****************�***********�*s****�**********�***: Statement Number: R080002082 Amount: $299.50 10/30/200801:54 PM Payment Method: Check Init: DDG Notation: Vail Alarms 2650 ----------------------------------------------------------------------------- Permit No: A08-0091 Type: ALARM PERMIT Parcel No: 2101-122-2600-1 Site Address: 4220 SPRUCE WAY VAIL LoCation: Total Fees: $299.50 This Payment: $299.50 Total ALL Pmts: $299.50 Balance: $0.00 ********�**************************�*****************************************�********+****� ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 FIRE ALARM PERMIT FEES 67.50 PF 00100003112300 PLAN CHECK FEES 232.00 ----------------------------------------------------------------------------- � APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED Project #: � ' 'rJ�O 'rj Building Permit #: F ' 1 � Alarm Permit #: — � � 970-479-2135 (/nspections) '� TOWN OF VAIL FIRE ALARM PERMIT APPLICATION ����� Commercial � Residential Fire Alarm shop drawings are required at time of 75 S. Frontage Rd. application submittal and must include information listed on the Vail, Colorado 81657 2nd page of this form. Application will not be accepted without this information. � ���,�/ CONTRACTOR INFORMATION Fire larm Contractor: ��� ��e. E-Mail Address: � Contractor Signature: Town of Vail Reg. No.: O� and Phone �� 2.1-0� � �� COMPLETE VALUATIONS FOR ALARM PERMIT (Labor 8� MateriafsL _ .�-� �-----��- � �- , , � � ;�; i� �, ��,�7 i { � '�� ,�, i Fire Alarm: $ ��j 00, O O s } 4� y . . � ,�..�o.,. �oy.` ...,...�ty Assessors �ce at 970-328-8640 or visif www.e__ _�kountv.com for Parcel # Parcel # �} �r") � �'Z �, 2 lv Qa \ Job Name: �' S m(M Ch�r'1 <a Legal Description Lot: , Block: Filing: Owners Name: r„n� a,�„^ . i r►.,, „_. Address:2� e S� ► N Address: ��, ;, Location of work: (i.e., floor, unit #, bldg. #) .�. Job Address: ) L n�.� c� r.` �., � Si � Subdivision: j��� Q � �jk�tik �=►%A Phone: Phone: �f�9-`j � �� Work Class: New ( ) Addition ( ) Remodel Repair ( ) Retro-fit ( ) Other ( ) Type of Bldg.: Single-family ( Two-family ( ) Mufti-family ( ) Commercial ( ) Restaurant ( ) Other ( ) No. of Existing Dwelling Units in this building: � No. of AcoommodaYbn units in this building: Does a Fire AIaRn Exist: Yes ) No (} Does a Fire Sprinkler System Exist: Yes () No �CI�XY�U .e�a�th.� ,��*,�*��*��*�xx****:*******�,�**�,�**�***�FOR OFFICE USE ONLY:�*:******���**����***�***��*****�**� ,�,��nu�p L.7 gy; AR�'��` , ,ated �` � ��� � , � � ---_ � .: � - 'r .r� . � — ,. osrz�ooa NOTE: THIS PERMIT MUST BE POSTED ON JOBS/TE AT ALL TIMES : �owxo�v�¢ . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 ELECTRICAL PERMIT Permit #: E08-0123 �36�s �� 30 ASFR Project #: PRJ07-0565 Job Address: 4220 SPRUCE WAY VAIL Location.....: 4220 SPRUCE WAY Parcel No...: 210112226001 OWNER GOLDMAN, SCOTT M. - CHENEY, 06/11/2008 26 SUMMIT ST PHILADELPHIA PA 19118 APPLICANT DANICI ELECTRIC 06/11/2008 Phone: 970-390-1173 PO BOX 7246 BRECKENRIDGE CO 80424 License: 114-E CONTRACTOR DANICI ELECTRIC 06/11/2008 Phone: 970-390-1173 PO BOX 7246 BRECKENRIDGE CO 80424 License: 114-E Desciption: REMODEL AND ADDITION: NEW WIRING Valuation: $12,000.00 Square feet: 2000 Status . . . : ISSUED Applied . . : 06/11/2008 Issued . . : 06/12/2008 Expires . .: 12/09/2008 ........«......«.....«*.........,...«*.�,�.........«....�..,...,..... FEE SUMMARY «..*.«««..,.....«.....««.,...,,.,*..,.........*.«.*.,..,.,..,�....,....*............. Electrical Permit Fee---------> $86.25 Total Calculated Fees--> $90.25 Investigation Fee--------------> $0.00 Additional Fees----------> $0.00 Will Call Fee--------------------> $4.00 Use Tax Fee-------------------> $0.00 TOTAL PERMIT FEE---> $90.25 Total Calculated Fees-------> $9025 Payments-----------------> $90.25 BALANCE DUE----------> $0.00 *.......«....*.....«...............«**,......*.......,.....«.,......,,...*.,*.....*..,.,..,.«...�.«.......«.......«...«.,.,...,.«*....*.*..�*.......,......«.....,,.,.,.,,..,.*.�. APPROVALS Item: 06000 ELECTRICAL DEPARTMENT 06/11/2008 JLE Action: AP ..«..,.........«.........,..«....*..«.......,..�..,.,.....«,,,,.,........«.*....*,....**....««..,.*..*.,....*.,...*........*..*.,...,,.*...�.,...«.«....*...,...#.,.......*�*.... CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. .......«...,,..,,...*.�,.*....«.«..,....,..........,.........«.*.,...*..,,.«.�.....«.,....,....*.,...*,...,....«*......,.......*...�.*,�...*..,.........«.,,...,,,.....*..**.,.,....�. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. �/f/J // Signature of Owner or Contractor �l/f�'�fJ /v�r�'V\`� --� Print Name elec_prm_041908 t Z �g Dat *************************�****�*****��**�*************+*�*****+��******+***+***�*****r****** TOWN OF VAIL, COLORADO Statement s****�*****�**�********�***�*******�*****r***********�*�*r*+***�*r***�*******�*r************ Statement Number: R080000940 Amount: $90.25 06/12/200809:29 AM Payment Method: Check Init: DDG Notation: Danici Electric 3295 ----------------------------------------------------------------------------- Permit No: E08-0123 Type: ELECTRICAL PERMIT Parcel No: 2101-122-2600-1 Site Address: 4220 SPRUCE WAY VAIL Location: 4220 SPRUCE WAY Total Fees: $90.25 This Payment: $90.25 Total ALL Pmts: $90.25 Balance: $0.00 *�+**************************�*************************�*******************+**************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ EP 00100003111100 ELECTRICAL PERMIT FEES 86.25 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- � APPLIGTION WILL NOT BE ACCEP'TED IF INCOMPLETE OR UNs� G ED ProjeCt #: F' '?-6S `, Building Permit #: O f � Electrical Permit #: 12 ��it�fi � 970-479-2149 (Inspections) ►!�!i 75 S. PY�ontsge Rd. Vail, Colorado 81657 TOWN OF VAIL ELECTRICAL PERMIT APPLICATION CONTRAGTOR INFORMATION COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Matierials) AMOUNT OF SQ FT IN STRUCTURE: ,� jj,(j� � ELECTRICAL VALUATION: $ � � � � � � ***************************************FOR OFFICE USE ONLY*******�I Il�*** �IUN* 1 ��Q ��J Il� r. f F:�cde�►�FORMS\PERMITS�Building�elecdcal_permi�ll-23-2005.DOC Page 1 of 2 13J23R005 32�� NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT : �nwxo�vnQ, . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ASFR Job Address: 4220 SPRUCE WAY VAIL Location.....: Parcel No...: 210112226001 OWNER GOLDMAN, SCOTT M. - CHENEY, 08/20/2008 26 SUMMIT ST PHILADELPHIA PA 19118 APPLICANT SKYLINE MECHANICAL P.O. BOX 1258 GYPSUM CO 81637 License: 121-M CONTRACTOR SKYLINE MECHANICAL P.O. BOX 1258 GYPSUM CO 81637 License: 121-M 08/20/2008 Phone:970-524-6809 08/20/2008 Phone:970-524-6809 Desciption: REPLACE FURNACE, RE-VENT WATER HEATER Valuation: $6,500.00 ALL TIMES Permit #: M08-0209 ( �b�s -o ��J Project #: Status . . . : Applied . . : Issued . . . Expires . .: `� � ` � � O � ` PRJ07-0565 ISSUED 08/20/2008 0812112008 02/17/2009 .«....« .........................................................................FEE SUMMARY............,......»...........«.......:..«.....................«.................,..: Mechanical Permit Fee---> $140.00 Will Call-----------> $4.00 Total Calculated Fees---> $179.00 Plan Check--------------> $35.00 Use Tax Fee-----> $0.00 Additional Fees----------> $0.00 Investigation-----------------> $0.00 TOTAL PERMIT FEE---> a179.00 Total Calculated Fees--> $179.00 Payments----------------> E179.00 BALANCE DUE--------> 50.00 •tt:wx�t�t+�+ri�f.*�xr+w*�t*�f��rrr+�*,trreir**►,t�::xx�t�r►���*wrxRrrr��wr*:ixrrr�***+nev��+r�ww**r*:rr�+�r�+►tsr�x,ti+x�+neea�,t��tenr�*:+ewye+r++af+rre+�+r*t+�rw,r�+.�sw+�,tt,�v�wn��+*+��,t�t�r�xax+.+.�t+t+� APPROVALS Item: 05100 BUILDING DEPARTMENT OS/20/2008 JLE Action: AP ex+3Rt�rr�rR:.ttti�fRt:r�iw�;f�,tt+�x:fr�#���+e+t*++�rxKk+�tx,rw�x:,tit+xw►*:ra+xr*�++t+wr+�t+snvww,t�»xw��+*+t���rr�i+*�+xK�3,t,rrxw�,t�:ww�waat���,erxxtt�+rxr�rt��+r�vr�t�++���*r�**�e�irix�+�t��++fr� CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. ♦:yf+++vexf+t�t►r�*+*xtt::f��++nrtx*:*:�trer*��x,triww+r*�xr►fr:�::,rw��►,t::sxf+r�wwx�+::+rr#x*r�:r�t�►tr�xr*i+t��w+w��+.+:xw��:#�rw,tr�+t�xvrk,rr�:tx*�+r*t,r++*ttt**ww�ttsrsw��t+r+rr*ntrri,v*�rt�wxx,ti+t DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed'an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. AM-4 SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( �ture of Guner or Contractor ii�/ � Print Name mechcanical_perm it_041908 �' �/ �'�' Date ***r**+�*********++******�**+�**+**�+**+***�*****�***************+***+*******�*****:*r****** TOWN OF VAIL, COLORADO Statement *�*****++******s*r*s********r**************r***r*****************+**************+***�**++*** Statement Number: R080001447 Amount: $179.00 08/21/200810:46 AM Payment Method: Check Init: DDG Notation: Skyline Mechanical 13534 ----------------------------------------------------------------------- Permit No: MOS-0209 Type: MECHANICAL PERMIT Parcel No: 2101-122-2600-1 Site Address: 4220 SPRUCE WAY VAIL Location: Total Fees: $179.00 This Payment: $179.00 Total ALL Pmts: $179.00 Balance: $0.00 ********�**�************************************+**+******************+�******************** ACCOUNT ITEM L1ST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ MP 00100003111100 MECHANICAL PERMIT FEES 140.00 PF 00100003112300 PLAN CHECK FEES 35.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- Rug 20 2008 8:10RM Skyline Mechanical IHC. 970-524-6810 p.l APPI.ICATION WI�L lVOT 8E ACCE�'TEO IF INCOMPLETE OR UNSI6NED p tG� Q� prpject #. , ��•! — Buikiing Permit #: - o Mechanicat Pen»it #: " �• 970-479-2349 (Inspectio�s) n1�1Vt)F YA1L �T?o •�179 -�) 38' cprw�c,� �s-�i���� �t �i�:■ �!C/�LlAV'f/�A� ncnurr w�ne �ri•�-�-rs�� 75 5. FrontaQe Rd. Vail, Colorad� 81657 Permit will not be accepted without the following: Provide Mec�wnical Room Layart dravim to scale to indude: � MeshaMcai Room Dime�sions ; Conrbustion Alr Ouc# 5ize and Location �Flue, Yent and Gas Line Sire and Lvcation Heat Loss Cal n qu pment �Cut/Spec St�eets ' F�x -� �� �us� COI�R°LETE VALUAl30N FOR MECHANICAL PERMIT (Labor 8� Materialsj MECHANICAL: $ 6� �d 4. O.0 CONTRACTOR INFaRMATiON **********************�*FOR OFFICE USE ON�Y********�***�*�****�********* e� ce.e• . .. � . . Planner Sion'-0}f: . ' •�Eed:�l1= � _ _ Fa/everl►one/fo�mslm�P�� �I� G� • !ia -� V NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT : �wrro�vnQ, � Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ADUP Job Address: 4220 SPRUCE WAY VAIL Location.....: Parcel No...: 210112226001 OWNER GOLDMAN, SCOTT M. - CHENEY, 09/02/2008 26 SUMMIT ST PHIWDELPHIA PA 19118 APPLICANT R 8 H MECHANICAL LLC 09/02/2008 Phone: (970) 328-2699 PO BOX 810 EAGLE CO 81631 License: 184-M CONTRACTOR R& H MECHANICAL LLC 09/02/2008 PO BOX 810 EAGLE CO 81631 License: 184-M Desciption: HEATER Valuation: Phone: (970) 328-2699 INTERIOR REMODEL: INSTALL RADIANT HEAT, BOILER AND WATER $20,500.00 Permit #: Project #: Status . . . : Applied . . : Issued . . . Expires . .: ALL TIMES M08-0217 �b�S-v �3b PRJ07-0565 ISSUED 09/02/2008 09105/2008 03l04/2009 .........................«.....................................«.......«........FEE SUMMARY.............:...............................................................»....... Mechanical Permit Fee---> $420.00 Will Call------------> $4.00 Total Calculated Fees---> $529.00 Plan Check----------------> $105.00 Use Tax Fee------> $0.00 Additional Fees-----------> $0.00 Investigation-----------------> $0.00 TOTAL PERMIT FEE--> 5529.00 Total Calculated Fees--> $529.00 Payments----------------> b529.00 BALANCE DUE---------> 50.00 •*�fr�+t++fri�+r*��rr�txwin+r*�*,t,t+t*wx�*R�::wxe�x��a4�x+++rt+r��*+�f+xx:,e+,t**rt*»rt�xx***���+r+ewwr►*r+xtw��+rx����ii��w�w�r***�ttri��*�**,r:tirr,eve+xf�+::++xw**�+r:�::�rw++rt�:xt,evew��+rtt�otr�+x APPROVALS Item: 05100 BUILDING DEPARTMENT .R*« 09/05/2008 cg* ��o**.x**»Aotion *AP �ff#*****A##t�#H##R**f►►ilRf##Yt*Rt4f#i*1�M4MIftiRftti**t*RRYi�R#*#4****R!►R********i!f*i*4#i!****Ot4###**1flfeMf�f4R�Rt�#fMr*M�fRib*##I�ftY►1iR*fMM*+tiYri CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC.. Cond: 31 (BLDG.): BOILERS SHALL BE MOUNTED ON F�OORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. rretff�t►�rw:�►►frfrrr,e+evvri►*�,rx�+e�rrif��*rtr+nerx�t�t�***�:�tww��*r��,e�we:►��twwxww���r��r�rr**3rf.��,r,rxwx++t����ww�x��tr+rt�xwrxatt,tx�x�wrnrt»x��+�rrr�:�t��+�xx�►�rw+�+rttiir+++xkxwxr��,ve,�+• mechcanical_perm it_041908 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM - Signature of Owner or Print Name mechcanical_perm it_041908 � S`� r � � Date +*******r*s*************r**r*****************�**************************************r**��*** TOWN OF VAIL, COLORADO Statement ****«•**r****�*****«*****��******�+*+*�***********�*********+��************++**r********�*** Statement Number: R080001562 Amount: $529.00 09/05/200803:31 PM Payment Method: Check Init: LC Notation: #14154/R&H MECHANICAL ----------------------------------------------------------------------------- Permit No: M08-0217 Type: MECHANICAL PERMIT Parcel No: 2101-122-2600-1 Site Address: 4220 SPRUCE WAY VAIL Location: Total Fees: $529.00 This Payment: $529.00 Total ALL Pmts: $529.00 Balance: $0.00 ***�++��**********�**************************+**********+�*********�************************ ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ MP 00100003111100 MECHANICAL PERMIT FEES 420.00 PF 00100003112300 PLAN CHECK FEES 105.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- APPLICATION WILL NOT BE aCCEPTED TF INCOMPLroj� �UNSIGNED n' O�VQ � IvJ Building Permit #: � � �� � ��� Mechanical Permit #: � . 970-479-2249 jinspections) ��pF�� T4WN OF VAIL MECHANICAL PERMiT APPLIC�ATION 75 s. Frontage �td. Permit will not be accepted w�tfiout the following: Vaii, Colorado 81657 Provide Mechanical Room Layout drawn to sca�e to include: o Mechanical Room �imensions o Cambustion Air Duct Size and tocation � r� Flue, Vent and Gas Une Size and Locatio� ❑ Heat Loss Calcs. ❑ Equipment Cut/5pec 5heets rANTR e["TnR iI�TFORMATYON � � -- � • �' H nical Contractor: Town of Va �{ N�e�n,�i.c�-4� (.�-� ��— �-Ma'I Address: o S 1 Cont ctor Stgnatu : OMPLETE VALUATION FOR MI MECHANICAL: $ � � �� • � Parcel # Job Name: �� O I� h��� Legal Description Lot: � � Reg. No.: I � ��. r_HeNZCAL P a�� �- Ot�ic�e at 970-328-8640 or visit � 7ob Address: rck: Filing: � A�ess��Gk,�l� �1- , �ll Jl� #�S & Materials) le-counlv com fo� Parcel � Subdivision: � � � E�gineer: Address: �'""'�. Detailed description of work: � �'� ��� � � �'x �� V�0���2. �r��wu. �.t� • JO�,l.�.2 � k�-S SS 0 t�1 ' Work Class: New ( ) Addition ( ) Alteration ( Repair ( ) Other ( ) Exterior Other poes an EHU exist at this focation: Yes () No () Boiler �ocation: Interior ) � ) � � Multi-fami Commercial ( ) Restaurarrt ( ) Other ( ) Type of Bldg: Single-familY () �uPlex ('� �Y i) No. of �xistlng Dwelling Units in this building; No. of Accommodation Units in this building: Gas Loqs O Wood/Pellet ) Wood Buming O � No/T e of Fireplaces Existin9' Gas ADpiiances O Wood Burnm NOT ALLOWED) No/Type of Freplaces Proposed: Gas Appliances () Gas Logs () Wood/Pellet () 9 i Is this a conversion from a wood buming fireplace to an EPA Phase II device? Yes () No () �1�.�� *****�***********�**�******** ***�*�*�******�*�**�****FOR CiFF�CE US� �l�LY . ._. .. ----- .,. .g ;.,__ ,,... ... .eJ.:� . . -E;� -� : - • Acoe •. .. ' `� ..... .. .. M;... . � . �, .• _ , . .. : . :... ,::_.�, ,.. .... ... . ,. ,,.. •••-•:. ... . .,.. •..'K: . �. . _ 07/26!�002 ann7 �7 �d i � �'M'� I ui.�li�• �`/ �fr�.�„ l �.1. � 3 � i � ! GJ tJ 1 �. l, I Y� VLJ . vl i� Y! 4i �'au/ � v�+ •v, `.�.. i I� o,`�t f �r �'N �-�� � � �D � � � s{;GC �� i Yi'a. i�+ e4 �' u/ �� t• a f-N r�� s Li G� � � �LL C 4V.� j� +1 �t ��.ri .'n 3 �. t'�C. u� i'�I ru +� 1�s.'f�`�, ��� .� c. r�.r�,�. S,`�Lc �c.%�1 t/<<.z t-��� ,.�� ��r�rn�y�,� ��� . .. ,���.E�, 5�rc,��eC�r6,� ;r�� � S�u��,_ iU �: �-�r r3.�.' r e r z� �! ��� �� s�-� 11+��1 � �, � ru �,�r�j�k rA �+N���v�,.��-i��� ��aS��'t �r,��t�,�g�.• � 1'' �r.�,.,1 [ � r9' � L � �' � (f ,� � t r ,0 � � � N N O O � N � "� � � i2° _ � m � _ D Z � D r z � � �. .� 7 O� 11 i _...�..,_....�......._ ..,,. . . . ,. . . ..... . . . . . . . . . .. . .. .. ...... � , � . ��� ��������.�.� , r�,�1�.C�9 R9^a=.�� �'.30�.Q33 � . !.?.8=.337 � ( F.R�.A SQUP+PE r� VALU� �t • UA G7 . $TCJ`s �G bUT ��oa�s 's �� � �` � ���'P�L ! ��� `�u • �' � 7�S � cEi � � y7 Z . � nr� �. � �' � �� � f."'� � ! �,� •. " �i� � . . � . '� , . . � � , `waas �,� 7 � j j y �� � . ! �{ �.',� i�� �� �`T { �.� � ► � � wiNao��� �� �.Z. . �,� . ��'� i l"Y �5 -,�,� • �� �:����.5` . � : '� � `� +� �� � ��,�i� � � � . . . .��+"a �� ' • , . : �.. I?�r=ELTRAi l�h r . • 1�x' � ��C ��-� ' . � . . . ' '! D0� � .i5 .� • . • ,. . s�.'i- . � .- • . . COI�ITR�tGTOP` ���"� ��.-�j:���'�4t�`: 4`sy ,' . ,�,.,-y"�;,C%7 �7„ , • ' � i U s C�IJTp�; . ADbR�SS: � . . " ' ��r`1Ct:J+ICY: � �� ��`.p[i �''"'] � •- . , • � , . ,abb��ss: . . • . � i � � �.� . . •�. - ?.�TfT"Ub�: . . .... PHOI�l�; . � � t� r � � I- ' • ' • 7UTA.L 3T►Js if�r�L? N�D�[?:• . . JQB '1�1A9E �"�"Ga_ � ►Lj �h,/ . � - � , GA�A a��• 2.�^� . � - AD�r��SS: . . . • ' • . ." Sf�OVtr M�I.T: . � • : : ��nMi7 �� ' •. 70 i AI. 3 i�Js: � 1�! �' �U '`��y' !�;-�;�'�., �DLJSaI�t?..1'!f $}?�rG, �,�j� � ' .� ►� ' , . ' . , . r��'t'-- � .1��`�'� �, nt� ! ' 1��.� a%� . , . � � 7 • L. �t � V ``� . . � ( L. ��.tL- �:J � e: J J ,�'�V t�ft., . � � �!� : �.:�.�' � � . . . , ; , � '�, � . �_ � 5'd 698ti'oN 1'd�INdH�3W H'8� Wdlti�Z 804Z 'Z 'daS NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT : �o�ro�vnu, ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970-479-2139 f.970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ASFR Job Address: 4220 SPRUCE WAY VAIL Location.....: Parcel No...: 210112226001 OWNER GOLDMAN, SCOTT M. - CHENEY, 09/24/2008 26 SUMMIT ST PHILADELPHIA PA 19118 APPLICANT RESORT MOUNTAIN ENTERPRISES 09/24/2008 Phone: 970-384-2748 P.O. BOX 2032 GLENWOOD SPRINGS CO 81602 License: 268-M CONTRACTOR RESORT MOUNTAIN ENTERPRISES 09/24/2008 P.O. BOX 2032 GLENWOOD SPRINGS CO 81602 License: 268-M Desciption: INSTALL TWO DIRECT-VENT FIREPLACES Phone:970-384-2748 Permit #: Project #: Status . . . : Applied . . : Issued . . . Expires . .: ALL TIMES M08-0241 � �� -° �3� PRJ07-0565 ISSUED 09/24/2008 0912412008 03/23/2009 Valuation: $7,500.00 ...« .....................«..................................«.,....:.............FEE SUMMARY.........................«...«....................................«.................. Mechanical Permit Fee---> $160.00 Will Call------------> $4.00 Total Calculated Fees--> $204.00 Plan Check----------------� $40.00 Use Tax Fee------> $0.00 Additional Fees-----------> $0.00 Investigation-------------> $0.00 TOTAL PERMIT FEE—> 5204.00 Total Calculated Fees--> $204.00 Payments------------> 5204.00 BALANCE DUE--------> 50.00 w+�,r�*:+r*rt�,t*:rf �tai�frtar�*+i+erf i+.+ntat����t*�ii*ir*���rt+w�*tr�*►��wt�+erfrarf+tr�f.��+m*i**�trw�t�e+.reiriw�w�it+e*ai+nt*►�:�+�r��+��rirra,r+�t�ar*+��wrtir+:��+a�rri:rn�:w�era�wt:ine3�r�+♦�iwa�e,e�t APPROVALS Item: 05100 BUILDING DEPARTMENT 09/24/2008 JLE Action: AP •ti*r�t,e*3�rri.�ive*t*�w�ti�,efrat�*+:+i+»trr*tw*:��*�eiir�tfwrt��xat►��itr�iwr�:r:��r,t++x�fr3+t*�it*+t+r��ttrwr��rnt�irart+�a++,rraie�*r�w�ttwfe�t,t�tt�*�it,v�t�i�tft+ra�tr�t+rtfe�:ei�:x�,tt�+erit+e*�tw+a� CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIEO BY TOWN OF VAIL. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. •:���t�r*�ir,t*irtr�+f�r�i+rtfr+�+efr�r�r�i+ernft*r+:rr*+�*airy-eitr�at�rirrie�:�*a�+�*���►ix�+tainrt+�e*tr►��rit:*irwr��w��awrrt+e*ai+,e*33w*at�xt�rwttt++t:��3+i:�er�:�e�+e+r�**�+r�,via,��++�+aa:r��:�x�r:��v DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS F R INSP TION SH BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM - PM. Q (>� �� a ure f Owner or Contrac or ate Print Name mechcan ical_perm it_041908 The foilowina items MUST be attached to this aertnit apalication Mechanical Room Lavout drawn to scale to include: Mechanical Room Dimensions Combustion Air Dud Size and Location Flue, Vent and Gas Line Size and Location Heat Loss Catculations _ Equipment Cut / Spec Sheets Project Address �l�!�:t� r�P��c� C,J ,� �U� CoMractor Information Company: . � ��'l�—/,[QC�iI� (M �/ �C_�— Company Address: 10 a)° � 3 2 C�y:� C� S State�� Zip: Contact Name: � � �- Contact Ph: � `C ��V T ��eII:�K 11 `� �7 �--� E-MaiL• Y��B D�K��.l� lG7 /� +�W/� _ Town of Vail �ontraotor Registration No: Property Ir�formation �� n r t�.,�-� 26- 00 Parcel #: '� Legal Description: Lot # Blk # Subdivision: Job Name: Owner Name: ���.j{J�L�^_,,� Mailing Address: (For Parcel � Contad Eagte County assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Architect ( ) Designer ( ) Ertgineer ( ) Name: Phone: Fax: E-Mail: . � I� ._ Project #: 1 � `� � � ( J c���.J Building Permit #: �� c� - n �3� Mechanicai Permit #: � v� � Q °`� � Detailed Description of Work: � , .�� �__ .. _ �.,,�u � ' .# r •� i (Use additional sheet ff necessary) Complete Valuation for Mechanical Permit: Mechanical $ .��� � Work Class: New ( ) Addition ( ) Remodel ( �epair ( ) Other ( ) Boiler Location: Interior ( ) Exterior ( ) Other ( ) No/Type Existing Fireplaces: Gas Appliances( ) Gas Logs () Wood/Pellet () NolType Proposed Fireplaces: Gas Appliances(71 Gas Logs () Wood�Pellet () Buiiding Type: Single-Family �Two-Family ( ) Multi-Family ( ) Commeraal ( ) Townhome ( ) Other Date Receiv � 1� � � �� �� �' � n �EP 2 � 2008 � �F �a� NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES : �ot��vn¢ � Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 PLUMBING PERMIT Permit #: P08-0103 ��� ���3� ASFR Job Address: 4220 SPRUCE WAY VAIL Location.....: 4220 SPRUCE WAY Parcel No...: 210112226001 OWNER GOLDMAN, SCOl'T M. - CHENEY, 09/08/2008 26 SUMMIT ST PHILADELPHIA PA 19118 , APPLICANT PLUMBING SYSTEMS, INC. PO BOX 3879 AVON COLORADO 81620 License: 277-P CONTRACTOR PLUMBING SYSTEMS, INC. PO BOX 3879 AVON COLORADO 81620 License: 277-P 0 Desciption: 1 Valuation 09/OS/2008 Phone:970-390-7763 09/08/2008 Phone:970-390-7763 GOLDMAN/CHENEY REMODEL $10,000.00 Project #: Status . . . : Applied . . : Issued . . . Expires . .: PRJ07-0565 ISSUED 09/08/2008 09/08/2008 03/07/2009 .+..........++..........+ ..................«.......................,t............ FEE SUMMARY #RfN�Yri#MfRtffRfYe�R+Rf##rtrtR1'*1f+Rff##rtffkir�HrffNwMi*1M�tfffMrt#M�t#Mk43#Rtl�4eHffM#w Plumbing Permit Fee--> $150.00 Will Call--_______________> $4.00 Total Calculated Fees---> $191.50 Plan Check---------------> $37.50 Use Tax Fee------------> $0.00 Additional Fees---------> $0.00 Investigation------------> $0.00 TOTAL PERMIT FEES--> 5191.50 Total Calculated Fees--> $191.50 Payments----------------> 5191.50 BALANCE DUE-----------> 50.00 ..............................,. �........ �.... «..............................,......................................., t.... «................ «..... ««.......................... «............. APPROVALS Item: 05100 BUILDING DEPARTMENT 09/08/2008 RLF Action: AP Item: 05600 FIRE DEPARTMENT �xrr��xwxwx���xx:�see��+r,ee��+�,+x��+t�wxxx+xxx��+.xxvw+v.,.xx�t+xx�a++xxxw+r,++.+.��**+*rxxe��wxxw�:s.ex+�rw,+.*++.�,e���+**x�+++�xRx++x+x�rrxwx+�+xxx+t�x.++xrxx��xx��+xx..Rx.�+�++++**x»xxi+t+xw� CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. «...:..........« .............................::.........«.«.......«.«....«...,..«....+«...,�........:....x.......:........,......,..:�...:........«......................................, DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTI SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM - 4 PM. �' U '— Q� Date / Signatur ner or Contractor � -� >> Print Na e plmbpermt1_041908 i r *�*******#**t******************�*********#************�#****�*******************#******�**** TOWN OF VAIL, COLORADO Statement ***+**�**r�********************+********************************r**********+**�*�*********** Statement Number: R080001584 Amount: $191.50 09/08/200803:55 PM Payment Method:Credit Crd Init: DDG Notation: credit card- James Harper ------------------------------------------------ Permit No: P08-0103 Type: PLUMBING PERMIT Parcel No: 2101-122-2600-1 Site Address: 4220 SPRUCE WAY VAIL Location: 4220 SPRUCE WAY Total Fees: $191.50 This Payment: $191.50 Total ALL Pmts: $191.50 Balance: $0.00 **+*****************�*********�+****s****************************************s**********+*** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- --------------------- PF 00100003112300 PLAN CHECK FEES 37.50 PP 00100003111100 PLUMBING PERMIT FEES 150.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 --------------------------------------------- TOWN OF VAIL PLUMBING PERMIT APPLICATION Project Address: Contractor Information Company: /X� lGl ir► �5 �Z � � ����"f � Company Address: �G " L � �`" c � �� City: �i�� State: � ) Zip: ��b �0 Contact Name: Contact Ph: �?�� Cell: E-Mail: Town of V'I Contra or Registration No: X � tractor atuPe (required) Plumbing Valuation (Labor & Material}o(J Plumbing $ ��D��� Property Information Parcel #: Legal Description: Lot # Blk # Subdivision: Job Name: Owner Name: Mailing Address: (For Parcel # Contact Eagle County assessors Office at 970-328-8640 or visit www.eaglecounty. us/patie) � Project #: � Building Permit #: �6 � ��c3 � Plumbing Permit #: Architect ( ) Designer ( ) Engineer ( ) Name: Phone: Fax: E-MaiL Detailed Description of Work: ��.� ►���'.�Y�-/��� . L , � C! (Use additional sheet if necessary) Work Class: New () Addition Remodel Repair () Other () Building Type: / Single-Family S/�wo-Family ( Commercial ( ) Townhome ( Multi-Family ( ) Other ( ) Date Received: V � ✓ r � **�******�*******************************************�***�*��******�************************ Statement TOWN OF VAIL, COLORADO ***********************************�*+*�**************+***********************************r� Statement Number: R080001745 Amount: $204.00 09/24/200811:32 AM Payment Method: Check Init: JLE Notation: 2957 MICHAEL NEMELKA ---------------=----------------------- Permit No: M08-0241 Type: MECHANICAL PERMIT Parcel No: 2101-122-2600-1 Site Address: 4220 SPRUCE WAY VAIL Location: Total Fees: $204.00 This Payment: $204.00 Total ALL Pmts: $204.00 Balance: $0.00 ***********************�******+**********+***�*****************+**************************** ACCOUNT ITEM LIST: Current Pmts Account Code Description ------------------------------ ---- MP 00100003111100 MECHANICAL PERMIT FEES 160.00 40.00 PF 00100003112300 PLAN CHECK FEES 4.00 WC 00100003112800 WILL CALL INSPECTION FEE ---------------------------------------- r 12-08-2008 Inspection Request Reporting Page 10 4:20 pm Vail CO _C_�Tv �r Requested Inspect Date: Tuesday, December 09, 2008 Inspection Area: �220 SPRUCE WAY VAIL Site Address: 4220 SPRUCE WAY A/P/D Information Activity: B08-0130 Type: A-BUILD Sub Type: ASFR Const Type: Occupancy : Use: Owner: GOLDMAN, SCOTT M. - CHENEY, MARYALICE Contractor: C& H CONSTRUCTION, LLC Phone: 970-949-1502 Architect: VAG, INC. ARCHITECTS & PLANNERS Phone: 970-949-7034 Description: GOLDMAN/CHENEY REMODEL ADDITION & INTERIOR REMODEL Requested Inspection(s) Item: Requestor: Comments: Assigned To: Action: 70 BLDG-Misc. C & H CONSTRUCTION, LLC asked for a Bldg. TCO , fire alarm is scheduled for 9:00 GDENCKLA Inspection Historv Item: 10 BLD06� C07/ CO / C071 Item: Item: Item: Item: Item: Item: Item: Item: G� Status: ISSUED Insp Area: jp Requeste Phone� 970 949� 1502 Entered By: DGOLDEN K Time Exp. r � � � �� �V C� �� r��� � C�� *" Approved "" ,o�+.,�• SC;RFMMER Action: AP APPROVED on u` "� �"���v Action: AP APPROVED `'� " ;k � ready for cement. Action: NR NOT READY FOR INSPECTIO� mpleted, subcontr Action�t AP APPROVED � W�II be rescheduli «,.,., r.,,,..,.. Comment: Steel in foundation wall OK. 20 BLDG-Foundation/Steel "' Approved "" Action: DN DENIED 07/01/08 Inspector: � 1gulick Comment: Not ready. Ha-If of forms not installeAction� nAP APt�'ROVED� 07/17/08 Inspector: JGG Comment: Footin steel OK. ready for concret Action: AP APPROVED 07/22/08 Inspec�or: JGG Comment: Steel in foundation wall OK. 30 BLDG-Framing *" Approved "' Action: AP APPROVED 09/05/08 Inspector: JGG Comment: . Framing OK, according to*approved plans and revisions. 50 BLDG-Insulation Approved Action: AP APPROVED 09/12/08 Inspector: JGG Comment: All blown-in and batts OK. 60 BLDG-Sheetrock Nail "" Approved *` 09/22/08 Inspector: JGG Action: AP APPROVED C11%17/08 I�nspector reBs�lOk. Garage not finisActon:2�AP APPROVED Comment: Garage dry wall nailing comp�eted and approved 70 BLDG-Misc. 533 PLAN-TEMP. C/O 534 PLAN -, FINAL C/O ��" 90 BLDG-Final Action: NO NOTIFIED 12/08/08 Inspe�ctor: JRM Comment: MESSAGEIAT 376S167TION REQUEST. A,M,P PERMITS NEED FINAL INSPECTION,. LEF REPT131 Run Id: 8767 . • 1 Inspect�on R �qu�s* rting Requested Inspect Date: Tuesday, December 09, 2008 Inspection Area: JRM Site Address: 4220 SPRUCE WAY VAIL AIP/D Infortnation Activity: M08-0241 Type: B-MECH Const Type: Occupancy . Owner: GOLDMAN, SCOTT M. - CHENEY, MARYALICE Contractor: RESORT MOUNTAIN ENTERPRISES Description: INSTALL TWO DIRECT-VENT FIREPLACES Sub Type: ASFR Use: Phone: 970-384-2748 ���o . _� Status: ISSUED Insp Area: JRM Requested Time: 01:00 PM - C&HH inal Phone: 376-1157 -or- 970-384- 2926 �place Entered By: DGOLDEN K "f"�°'"`� Time Exp: irep ace i no operate. Inspection wi e resc eduled. /� '� �" v � Insaection Historv Item: 200 MECH-Roug h "" Approved "" Action: AP APPR D 10/07/OS- Inspector: JGG Comment: 1" clearance met on Vermont unit. Gas pipe was secur d. Item: 310 MECH-Heating. Item: 315 PLMB-Gas PipAg Item: 330 MECH-Supp y Item: 340 MECH-Misc. Item: 390 MECH-Final Action: CR CORRECTION REQUIRED 12/05/08 Inspector: JGG Comment: Fireplace did not operate. Inspection will be rescheduled. Ruri Id: 8767 REPT131 E08-0123: Entries for Item:190 - ELEC-Final 10:02 01/31/2013 Action Comments By Date Unique_ Ke AP shahn 12/03/2008 A000120 588 Total Rows: 1 Page 1 M08-0217: Entries for Item:390 - MECH-Finai 10:02 01/31/2013 Action Comments By Date Unique_ Ke AP Radiant in-floor heat OK. Boiler final insp. OK. JGG 12/02/2008 A000120 Gara e and M. bed baseboard heat OK. 543 Total Rows: 1 Page 1 12-08-2008 Inspection Request Reporting Page 43 4�20 pm Vail C� - Citv Of Requested Inspect Date: Tuesday, December 09, 2008 Inspection Area: JRM Site Address: 4220 SPRUCE WAY VAIL 4220 SPRUCE WAY A/P/D Information Activity: P08-0103 Type: B-PLMB Sub Type: ASFR Const Type: Occupancy : Use: Owner: GOLDMAN, SCOTT M. - CHENEY, MARYALICE Contractor: PLUMBING SYSTEMS, INC. Phone: 970-390-7763 Description: GOLDMAN/CHENEY REMODEL Re uested Ins ection s ���' Item: -Final Requesto � MBING SYSTEMS, INC. Assigned. : CKLA Action: ime Exp: Inspection Historv Item: 210 PLMI Item: 220 PLMI Item: 230 P Item: 240 P Item: 250 PLM Item: 260 PLM Item: 290 PLM Status: ISSUED Insp Area: JRM Requested Time: 01:30 PM Phone: 970-390-7763 Entered By: DGOLDEN K n .W.V. "" Approved "` spector: JGG �ugh plumbing and DWV OK. la%r ig `* Approved'* spector: JGG �s pipe tested at 16 psi, Ok. Action: AP APP Action: AP APPROVED REPT131 Run Id: 8767