Loading...
HomeMy WebLinkAboutShotcreteReport(18-6523.Shotcrete.0005).pdf Client: Chad Salli Town of Vail GROUND 1309 El 81rn Drive ENGINEERING Red Sandstone Parking Garage Report Date: Jul 17,2018 Work Order No.: 18-6523.Shotcrete.0005;ver:4 Work Order Date: Jun 18,2018 Reviewed by: Shane Sorensen Shotcrete Placement Contractor: Schnabel Performed by: Chris Leeper Nozzleman: Nick Quantity Placed: 15 yd3 Structure Type, Thickness: Soil Nail Retaining Wall,8 in Weather: Mostly Sunny Finish, Curing Methods: Gun Finished, None Placement Location: North and East Soil Nail Wall:Sta 2+20 to 3+15,8225'to 8229' Placement Area Conforms Does Not Conform Not Applicable Not Observed Surface/Substrate Condition: U U Reinforcing Steel Condition: U U Means and Methods Placement Method: Reinforcing Encasement: DI Presence of Voids: DI Sand Pockets or Lamination: Finish and Curing Finish Methods: El Curing Methods: El On-Site Notifications Name Company Tom Highsmith Haselden Construction Shotcrete Specifications Fresh Properties Hardened Properties 717-Shotcrete Air Content 5 to 9% Average Compressive 4000 min. Shotcrete Strength 717-Shotcrete Slump 2 to 4 inches Conformance Test Age 28 min. Shotcrete Material Material Property Target Casey,8.5 SHOTCR Results apply only to the specific items and locations referenced and at the time of testing,observations or special inspections.This report should not be reproduced,except in full,without the written permission of GROUND Engineering Consultants,Inc. www.groundeng.com Englewood I Commerce City I Loveland I Granby I Gypsum Page 1 of 3 Client: Chad Salli Town of Vail GROUND 1309 Elkhorn 81rn Drive ENGINEERING Red Sandstone Parking Garage Report Date: Jul 17,2018 Work Order No.: 18-6523.Shotcrete.0005;ver:4 Work Order Date: Jun 18,2018 Reviewed by: Shane Sorensen Shotcrete Shotcrete Sampling Quantity Truck Ticket Air Temp Water Sample No. Location (yd') Number Number Batch Time Test Time (°F) Added (gal) 4 East Wall:Sta 3+10,8228' 7.5 149 316378 11:22 AM 12:40 PM 65 0 Physical Properties of Shotcrete Sample No. Concrete Temp. (°F) Slump(in) Air Cont. (%) Meas. Vol. (ft3) Empty Meas. (lb) Full Meas. (Ib) Unit Wt. (pct) Panels Cast 4 72 2.5 8.0 .249 7.78 41.98 137.3 Yes Compressive Strength of Shotcrete Cores (ASTM C42 / AASHTO T24) Sample No.: 4 Laboratory ID: Shotcrete27 Age(d) Conformance Diameter(in) Area(in2) Length(in) L/D Ratio Correction Maximum Corrected Core Factor Load(lb-f) Strength(psi) 7 No 1.97 3.05 4.00 2.0 1.00 19,220 6,300 7 No 1.97 3.05 4.00 2.0 1.00 19,200 6,300 7 No 1.97 3.05 4.00 2.0 1.00 20,380 6,680 Compressive Strength of Shotcrete Cores (ASTM C42 / AASHTO T24) Sample No.: 4 Laboratory ID: Shotcrete28 Age(d) ConformanceCorrection Maximum Corrected Diameter(in) Area(in2) Length(in) L/D Ratio Core Factor Load(lb-f) Strength(psi) 28 Yes 1.98 3.06 4.00 2.0 1.00 22,010 7,190 28 Yes 1.97 3.05 4.00 2.0 1.00 21,640 7,100 28 Yes 1.97 3.05 4.00 2.0 1.00 22,340 7,330 Average Conformance Compressive Strength(psi) 7,210 Results apply only to the specific items and locations referenced and at the time of testing,observations or special inspections.This report should not be reproduced,except in full,without the written permission of GROUND Engineering Consultants,Inc. www.groundeng.com Englewood I Commerce City I Loveland I Granby I Gypsum Page 2 of 3 Client: Chad Salli Town of Vail GROUND 1309 El 81rn Drive ENGINEERING Red Sandstone Parking Garage Report Date: Jul 17,2018 Work Order No.: 18-6523.Shotcrete.0005;ver:4 Work Order Date: Jun 18,2018 Reviewed by: Shane Sorensen Shotcrete Photos eQ r .04,44 • A i. *Fr A- 'liiiiiiri„ - - ......Ar....nirlie: . :'.. .1.1441;11111111 ``;; _ -+'S .-•ter t"-T ".. � / ' . Shotcrete Shotcrete Resultsapply only to the specific items and locations referenced and at the time of testing,observations or special inspections.This report should not be reproduced,except in full,without the written permission of GROUND Engineering Consultants,Inc. www.groundeng.com Englewood I Commerce City I Loveland I Granby I Gypsum Page 3 of 3