Loading...
HomeMy WebLinkAboutShotcreteReport(18-6523.Shotcrete.0024).pdf Client: Chad Salli Town of Vail GROUND 1309 El 81rn Drive ENGINEERING Red Sandstone Parking Garage Report Date: Aug 2,2018 Work Order No.: 18-6523.Shotcrete.0024;ver: 1 Work Order Date: Jul 31,2018 Reviewed by: Shane Sorensen Shotcrete Placement Contractor: Schnabel Performed by: Chris Leeper Nozzleman: Nick Quantity Placed: 30 yd3 Structure Type, Thickness: Soldier Beam Wall,8 in Weather: Sunny Finish, Curing Methods: Other,None Placement Location: Soldier Beam Wall Placement Area Conforms Does Not Conform Not Applicable Not Observed Surface/Substrate Condition: U U Reinforcing Steel Condition: Means and Methods Placement Method: Reinforcing Encasement: DI Presence of Voids: DI Sand Pockets or Lamination: Finish and Curing Finish Methods: El Curing Methods: El On-Site Notifications Name Company Tom Highsmith Haselden Construction Shotcrete Specifications Fresh Properties Hardened Properties 717-Shotcrete Air Content 5 to 9% Average Compressive 4000 min. Shotcrete Strength 717-Shotcrete Slump 2 to 4 inches Conformance Test Age 28 min. Shotcrete Material Material Property Target Casey,8.5 SHOTCR Results apply only to the specific items and locations referenced and at the time of testing,observations or special inspections.This report should not be reproduced,except in full,without the written permission of GROUND Engineering Consultants,Inc. www.groundeng.com Englewood I Commerce City I Loveland I Granby I Gypsum Page 1 of 2 Client: Chad Salli Town of Vail GROUND 13019 El 81rn Drive ENGINEERING Red Sandstone Parking Garage Report Date: Aug 2,2018 Work Order No.: 18-6523.Shotcrete.0024;ver: 1 Work Order Date: Jul 31,2018 Reviewed by: Shane Sorensen Shotcrete Shotcrete Sampling Quantity Truck Ticket Air Temp Water Sample No. Location (yd') Number Number Batch Time Test Time (°F) Added (gal) 14 Sta 0+15(8197') 10 145 317302 11:48 AM 1:45 PM 80 5 Physical Properties of Shotcrete Sample No. Concrete Temp. (°F) Slump(in) Air Cont. (%) Meas. Vol. (ft') Empty Meas. (lb) Full Meas. (lb) Unit Wt. (pct) Panels Cast 14 80 2.25 6.3 .249 7.78 42.4 139.0 Yes Photos Illr- ,/ - - I\- I J ei 7 1.4,-- 3, — —$.y--. .:'''T'Al' ti ' - -fir 'I 1 1 I' I, r, _ _ //' ', 411111: tn 'M Iris \N Shotcrete Shotcrete Results apply only to the specific items and locations referenced and at the time of testing,observations or special inspections.This report should not be reproduced,except in full,without the written permission of GROUND Engineering Consultants,Inc. www.groundeng.com Englewood I Commerce City I Loveland I Granby I Gypsum Page 2 of 2