Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
F18-0055_Approved Documents_1534196189.pdf
75 South Frontage Road Fire-Construction Permit 0West, TOWN OF VAIL F18-0055 TOWN Vail,CO 81657 Issued: 08/13/2018 TOWN Or VAIL Office:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 2109 N FRONTAGE RDW(210311424025) (210311424025 ) Unit#: Parcel Number: 210311424025 DESC: PARCELA Subdivision:VAILCOMMONS CONDO BK-0709 PG-0894MAP 10-29-96BK-0709 Legal Description: PG-0960 DEC 10-29-96BK-0709 PG-0962 DEC 10-29-96BK-0727 PG-0864 MAP 05-28-97R654465 DEC 04-30-98R769007MAP 10-03-01 Contacts Contact Type:Applicant Full Name:Don Anderson Address: PO Box 3940331 Metcalf Rd Avon,CO 81620 Phone: 9707488888 Contact Type:Property Owner Full Name:TOWNOF VAIL DILLON REAL ESTATECO Address: Phone: None Contractor Contractor Type:Fire Protection Company: Meridian IntermountainNail Electronics State License#: Phone: 970-748-8888 Projectlnformation Project Name:Dr.Moses Dental Office 2018 Project Description: Reconfigure Sprinkler Heads in Unit Fees Paid Account#:001-0000.31111.00-Fire Suppression Permit Fee Fee Amount: $191.25 Account#:001-0000.31123.00 Fire Suppression Review Fee Fee Amount: $432.00 Total Paid: $623.25 Conditions Issued By:Town of Vail Fireand Emergency Services Department NOTICE:By issuance of this Permitthe applicant agrees to complyto all Titles of the Town of Vail Code and all applicable State and Federal law.Failure to do so will void this Permit and the applicant shall forfeit all applicablefees. °11111 ' PERMIT FEE RECEIPT TOWN OF VAIL Case # F18-0055 Date Printed: 08/08/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: F18-0055 Status: Created Permit Number: Date Started: 08/03/2018 Permit Type: Fire-Construction Permit Subc ases Fire Suppression Lot Number: Property: 2109 N FRONTAGE RDW(210311424025)(210311424025) Contacts Contact Type: Applicant Company Name: Meridain Intermountain Full Name: Don Anderson Address: PO Box 3940 331 Metcalf Rd Avon,CO 81620 Email: Dispatch@meridianintermountain.com Contact Type: Property Owner Full Name: TOWN OF VAIL DILLON REAL ESTATE CO Address: Permit Fees Fee Information Account Amount Fire Suppression Permit Fee 001-0000.31111.00 $191.25 Fire Suppression Review Fee 001-0000.31123.00 $432.00 Payment Information Date Paid Payment Type Amount Fire Suppression Review Fee 08/08/2018 Check $432.00 Paid By:Vail Alarm/Meridian-Notes:17922-Vail Alarm/Meridian Fire Suppression Permit Fee 08/08/2018 Check $191.25 Paid By:Vail Alarm/Meridian-Notes:17922-Vail Alarm/Meridian FEE TOTAL $623.25 AMOUNT PAID $623.25 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 08/08/2018-4:01:59 PM-Generated by:do ouc h 1 /1 tIII. 'El Worldwide Contacts l/1 Fire Protection www.tyco-fire.com Products Series TY-FRB — 28, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General when expo sed to co rro sive atmo- sp heres.Altho ugh corrosion-resistant Description coated sprinklers have passed the p standard corrosion tests o f the appli- The TYCO Series TY-FRB, 2.8, 4.2, cable approval agencies, the testing is , , ` L - 5.6,and 8.0 K-factor, Upright,Pendent, not representative o f all possible co r- and Recessed Pendent Sprinklers ro sive atmospheres. Consequently, described in this data sheet are quick it is reco mmended that the end user respo nse,standard coverage,decobe co nsulted with respect to the suit- - R it rative 3 mm glass bulb-type spray ability of these co atings fo r any given sprinklers designed for use in light o r corrosive enviro nment.The effects o f ordinary hazard,commercial amb lent temperature, concentration o f cies such as banks,commeho rcial occupan-nd shop- chemicals, and gas/chemical velocity, - -4`-r: -- _ ping malls. sho uld be co nsidered,as a minimum, — -',_110 along with the corrosive nature o f the The recessed versio n o f the Series chemical to which the sprinklers will be TY-FRB Pendent Sprinkler, where exposed. applicable, is intended fo ruse in areas An intermediate level of the Series with a finished ceiling. This recessed TY-FRB Pendent Sprinklers is detailed pendent sprinkler uses one of the in Technical Data Sheet TFP356, and following: Sprinkler Guards are detailed in Tech- • A two-pieceStyle 10 (1/2 inch NPT) nical Data Sheet TFP780. r" v o rStyle 40(3/4 inch NPT) Recessed Escutcheonwith 1/2 inch (12,7 mm) NOTICE • ' . • o f recessed adjustment o r up to 3/4 The Series TY-FRB, 2.8, 4.2, 5.6,inch (19,1 mm) of total adjustmentfro mthe flush pendent position, ora and 8.0 K-factor, Upright, Pendent, TI and Recessed Pendent Sprinklers • A two-pieceStyle 20 (1/2 inch NPT) described herein must be installed o rStyle 30(3/4 inch NPT) Recessed and maintained in compliance with +' Escutcheo n with 1/4 inch (6,4 mm) this document and with the applica- o f recessed adjustment o r up to 1/2 ble standards of the National Fire Pro- inch (12,7 mm) of total adjustment tection Association, in addition to the fro mthe flush pendent position. standards of any authorities having - The adjustment provided by the jurisdiction.Failure to do so may impair Recessed Escutcheon reduces the the performance of these devices. Sprinkler accuracy to which the fixed pipe drops The owner is responsible for maintain- Identification to the sprinklers must be cut. ing their fire protection system and Co rro sio n-resistant co atings, where devices in proper operating condition. Number (SIN) applicable, are utilized to extend the life The installing contractor or sprinkler o f copper alloy sprinklers beyond that manufacturer should be contacted with TY1131 - Upright 2.8K, 1/2"NPT which would otherwise be obtained any questions. TY1231 - Pendent 2.8K,1/2"NPT TY2131 - Upright 4.2K,1/2"NPT TY2231 - Pendent 4.2K,1/2"NPT IMPORTANT TY3131 - Upright 5.6K,1/2"NPT Always refer to Technical Data TY3231 - Pendent 5.6K,1/2"NPT Sheet TFP700 for the "INSTALLER TY4131 - Upright 8.0K,3/4"NPT WARNING" that provides cautions TY4231 - Pendent 8.0K,3/4"NPT with respect to handling and instal- TY4831 - Upright 8.0K,1/2"NPT lation of sprinklersystemsand com- TY4931 - Pendent 8.0K, 1/2"NPT ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 NOVEMBER 2015 TFP171 TFP171 Page 2 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Co mpressio n is indicated o n ISO 7-1 can be provided o n ESCUTCHEON 2 - Butto n Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflecto r* SURFACE 7 - Bushing 7/16"0 101 r 4,4"/ � 1(11,1mm) `��11� � 3 i NOMINAL t 2 1/4" MAKE-IN (57,2 mm) 2 ______ (55,6 mm) 1 1 1-9/16" 41 I 4 . (39,7 mm) . �� 5 \ "-Am 1 //ffilln., .. .firv\ 6 1/2" NPT** } WRENCH STYLE 10 o r20 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 1/2I NCH NPT *Temperature rating ** Pipe threadconnectionsper 1 - Frame 3 - Sealing 5 - Compression is indicated o n ISO 7-1 can be provided o n ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflecto r* SURFACE iyrI' A ml...4.—li7/16" ,--... (11,1 mm)NOMINAL2 3/16" ,. �MAKE IN (55,6 mm)� 2-3/16" /1W1-1/2" 1 I 4 (55,6 mm) (38,1 mm) I �5 \ --- 1 --., .-- Ilia - 6* 1/2" NPT** f WRENCH STYLE 10 o r20 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 1/2I NCH NPT *Temperature rating ** Pipe threadconnectionsper 1 - Frame 3 - Sealing 5 - Co mpressio n is indicated o n ISO 7-1 can be provided o n 2 - Button Assembly Screw Deflector. special request. ESCUTCHEON 4 - Bulb 6 - Deflector* PLATE SEATING SURFACE 1 //��_^ , �, 1 _ 1 7/16" .—.— ���� 3 (11,1 mm) 1.'',�- I1, NOMINAL �� p !� 2 1 MAKE-IN 2-3/16"I / �iLA ii (55,6 mm) 14if 4 `�� 2 3/16" 1 1 1/2" (55,6 mm) (38,1‘') mm) _ 111 6* 1/2" NPT** f WRENCH STYLE 10 o r20 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 1/2INCHNPT TFP171 Page 3 of 10 *Temperature rating ** Pipethread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE A 1 1/2" I i 3 (12,7 mm) IMAM 11r - A - 1 NOMINAL I� 2-5/16" L4if _ 4 2 MAKE IN (58,7 mm)1# A �- ir Fe 1111 2-1/4" (57,2 0 1-9/16" 4 1 (39,7 mm) r—5 1 3/4"NPT** WRENCH STYLE 30 or40 FLATS RECESSED 2-7/8"(73,0 mm)DIA. – UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,3/4INCH NPT CEILINGPLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 - Deflector* 1 Assembly 3 4 - Bulb 10 7/16" (11,1 mm) 2 1/4" • NOMINAL1 ) (57,2 mm) A'k. ® 2 MAKE IN * Temperature rating is 2 3/16" 1-9/16" I 4 indicated on Deflector. (55,6 mm) 1 i (39,7 mm) —_-- ��5 ** Pipe thread connections re per ISO 7-1 can be \ 1 - -- 1 -�+ - 6 * provided on special 1/2" NPT** WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 1/2INCHNPT 4 Cs WRENCH RECESS le WRENCH RECESS (END"A"USED FOR 1/2" NPT MODELS) .v t WRENCH RECESS • (END"B"USED FOR 3/4"NPT MODELS) PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHINGAREA FIGURE 6 FIGURE 7 W-TYPE 6 SPRINKLER W-TYPE 7 RECESSED WRENCH SPRINKLER WRENCH TFP171 Page 4 of 10 Technical Design Do not attempt to compensate for insufficient adjustment in the Escutch- Data Criteria eon Plate by under-or over-tightening the sprinkler. Re-adjust the position of Approvals The TYCO Series TY-FRB, 2.8, 4.2, the sprinklerfitting to suit. UL and C-UL Listed 5.6,and 8.0 K-factor, Upright,Pendent, Series TY-FRB Up right and Pendent FM,LPCB,and NYC Approved and Recessed Pendent Sprinklers are Sprinklers Refer to Table A and B forcomplete intended for fire protection systems The Series TY-FRB Pendent and approval information including corrosion- designed in accordance with the stan- Upright Sprinklers must be installed resistant status. dard installation rules recognized by in accordance with the following Maximum Working Pressure the applicable Listing or Approval instructions. Refer to Table C. agency (such as, UL Listing is based on the requirements of NFPA 13, and Step 1. Install Pendent sprinklers in the Discharge Coefficient FM Approval is based on the require- pendent position. Install upright sprin- K=2.8 gpm/psY2(40,3 Ipm/bar'/2) ments of FM's Loss Prevention Data klers in the upright position. K=4.2 gpm/psY2(60,5 Ipm/bar'/2) Sheets). Only the Style 10, 20, 30, or Step 2. With pipe-thread sealant K=5.6 gpm/psY2(80,6 Ipm/bar'/2) 40 Recessed Escutcheon,as applica- applied to the pipe threads, hand- K=8.0 gpm/psY2(115,2 Ipm/bar'/2) ble,is to be used for recessed pendent tighten the sprinkler into the sprinkler Temperature Rating installations. fitting. Refer to Table A and B. Step 3. Tighten the sprinkler into the Finishes Installation sprinklerfitting using only the W-Type Sprinkler:Refer to Table D. The TYCO Series TY-FRB,2.8,4.2,5.6, 6 SprinklerWrench(Figure 6).With ref and 8.0 K-factor, Upright,Pendent,and erence to Figures 1 through 5, apply Recessed Escutcheon:Signal or Pure Recessed Pendent Sprinklers must the W-Type 6 Sprinkler Wrench to the White,Jet Black,ChromePlated,or sprinkler wrench flats. Natural Brass be installed in accordance with this section. Series TY-FRB Recessed Pendent Physical Characteristics Sprinklers Frame Bronze General Instructions The Series TY-FRB Recessed Pendent Button Brass/Copper Do not install any bulb-type sprinkler Sprinklers must be installed in accor Sealing Assembly..Beryllium Nickel w/TEFLON if the bulb is cracked or there is a loss p Bulb Glass of liquid from the bulb.With the sprin- dance with the following instructions. Corn pressionScrew Bronze kler held horizontally,a sm all air bubble Step A.Afterinstalling the Style 10, 20, Deflector Copper/Bronze Bushing(K=2.8) Bronze should bepresent.The diameterof the 30, or 40 Mounting Plate, as app lica- air bubble is approximately 1/16 inch b le,over the sprinkler threads and with Operation (1,6 mm)for the 135°F (57°C)and 3/32 pipe-thread sealant applied to the pipe inch(2,4 m m)forthe 286°F(141°C)tern- threads,hand-tighten the sprinkler into The glass bulb contains a fluid that perature ratings. the sprinklerfitting. expands when exposedto heat.When A leak-tight 1/2 inch NPT sprinkler Step B. Tighten the sprinkler into the the rated temperature is reached, the joint should be obtained bapp lying a sprinkler fitting using only the W-Type expands sufficiently to shatter the glass bulb, allowing the sprinkler to minim um to maxim um torque of 7 to 7 Recessed Sprinkler Wrench (Figure activate and water to flow. 14 ft.-lbs.(9,5 to 19,0 Nm).A leak tight 7). With reference to Figures 1 to 4, 3/4 inch NPT sprinkler joint should be apply the W-Type 7 Recessed Sprinkler obtained with a torque of 10 to 20 ft.- Wrench to the sprinkler wrench flats. lbs.(13,4 to 26,8 Nm).Higher levels of Step C. After ceiling installation and torque can distort the sprinkler Inlet finishing, slide on the Style 10, 20, 30, with consequent leakageorim pairment of the sprinkler. or 40 Closure over the Series TY-FRB Sprinklerand pushthe Closure overthe Mounting Plate until its flange comes in contact with the ceiling. TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 5) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTER*** FACTOR COLOR BRASS PLATED 135°F(57°C) Orange PENDENT 155°F (68°C) Red (TY1231) and 175°F(79°C) Yellow 1, 2,3,4 UPRIGHT (TY 1131) 200°F(93°C) Green 286°F(141°C) Blue 135°F (57°C) Orange 2.8 RECESSED 68° 155°F C 1/2"NPT PENDENT 155 ( ) Red (TY1231)* 175°F(79°C) Yellow Figure 8 200°F(93°C) Green 1, 2,4 135°F(57°C) Orange RECESSED PENDENT 155°F (68°C) Red (TY1231)** 175°F(79°C) Yellow Figure 9 200°F(93°C) Green 135°F (57°C) Orange PENDENT 155°F (68°C) Red (TY2231) and 175°F(79°C) Yellow UPRIGHT (TY2131) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 4.2 RECESSED 1/2"NPT PENDENT 155°F (68°C) Red 1, 2 (TY2231)* 175°F(79°C) Yellow Figure 10 200°F(93°C) Green 135°F(57°C) Orange RECESSED PENDENT 155°F (68°C) Red (TY2231)** 175°F(79°C) Yellow Figure 11 200°F(93°C) Green NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. "Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. "*Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. ***Frame and Deflector only. N/A:Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH(See Note 8) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTER*** LEAD FACTOR COLOR BRASS PLATED COATED 135°F(57°C) Orange PENDENT (TY3231) 155°F(68°C) Red and 175°F(79°C) Yellow 1, 2,3,4,5,6,7 1, 2,3,5 UPRIGHT 200°F(93°C) Green (TY3131) 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red 5.6 PENDENT 175°F(79°C) Yellow 1, 2,4,5 N/A 1/2"NPT (TY3231)* Figure 12 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT 175°F(79°C) Yellow 1, 2,3,4,5 N/A (TY3231)** Figure 13 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange PENDENT (TY4231) 155°F(68°C) Red and 175°F(79°C) Yellow 1, 2,3,4,5,6,7 1, 2,5 UPRIGHT 200°F(93°C) Green (TY4131) 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red 8.0 PENDENT 175°F(79°C) Yellow 1, 2,5 N/A 3/4"NPT (TY4231)* Figure 14 200°F(93°C) Green 286°F(141°C) Blue _ 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT 175°F(79°C) Yellow 1, 2,3,5 N/A (TY4231)** Figure 15 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange PENDENT 155°F(68°C) Red 8.0 (TY4931) 1/2"NPT and 175°F(79°C) Yellow 1, 2,4,5,6 1, 2,5 UPRIGHT 200°F(93°C) Green (TY4831) 286°F(141°C) Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification B oard(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Tyco Fire Suppression&B uilding Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification B oard(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. 'Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. '*Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. ''*Frame and Deflector only. N/A:Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME POLYESTER LEAD FACTOR BRASS PLATED COATED PENDENT(TY1231) and 2.8 UPRIGHT(TY1131) 175 PSI(12,1 BAR) N/A 1/2" NPT RECESSED PENDENT(TY1231) PENDENT(TY2231) and 4 2 UPRIGHT(TY2131) 1/2"NPT 175 PSI(12,1 BAR) N/A RECESSED PENDENT(TY2231) PENDENT(TY3231) and 5.6 UPRIGHT(TY3131) OR 250 PSI BAR) BAR) 1/2"NPT RECESSED (SEE NOTE 1) PENDENT(TY3231) PENDENT(TY4231) 175 PSI and (12,1 BAR) 8.0 UPRIGHT(TY4131) 3/4"NPT 175 PSI(12,1 BAR) RECESSED N/A PENDENT(TY4231) PENDENT(TY4931) .0 175 PS 1/28 NPT and 175 PSI(12,1 BAR) (12,1 BAIR) UPRIGHT(TY4831) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Under- writers Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE Care and have not operated,should be replaced Care must be exercised to avoid if they cannot be completely cleaned damage to the sprinklers -before, Maintenance by wiping the sprinkler with a cloth or during, and after installation. Sprin- by brushing it with a soft bristle brush. klers damaged by dropping,striking, The TYCO Series TY-FRB must be Care must be exercised to avoid wrench twist/slippage,orthe like,must maintainedand serviced in accordance damage to the sprinklers before, be replaced.Also, replace any sprin- with this section. during, and after installation. Sprin- kler that has a crackedbulborthat has Before closing a fire protection system tion klers damaged by dropping,striking, liquidfrom its bulb.(Ref.Installa main control valve for maintenance wrenchtwist/slippage,orthe like,must Section). work on the fire protection system be replaced.Also, replace any sprin- Initial and frequent visual inspections of that it controls, obtain perm issionto kler that has a cracked bulb or that has random samplesarerecommendedlor shut down the affected fire protection lost liquid from its bulb.(Ref.Installa- corrosion-resistant sprinklers to verify systems from the proper authorities tion Section.) the integrity of the corrosion-resistant and notify all personnel who may be The owner is responsible for the material of construction. Thereafter, affected by this action. inspection,testing,and maintenance of annual inspections per NFPA25 should their fire protection system and devices suffice. Absence of the outer piece of an in compliancewith this document,as escutcheon, which is used to cover p Inspections of corrosion resistant a clearance hole, can delay sprinkler well as with the applicable standards sprinklers are recom m ended at close operation in a fire situation. of the National Fire Protection Asso- range, instead of from the floor level ciation (e.g., NFPA 25), in addition to per NFPA. Inspection at close range Sprinklers which are found to be the standards of any other authorities can better determine the exact sprin- leaking or exhibiting visible signs of having jurisdiction.Contact the install- kler condition and the long-term integ- corrosion must be replaced. ing contractor or sprinkler manufac- rity of the corrosion-resistant material, Automatic sprinklers must never be turer regarding any questions. which can beaffectedbythe corrosive painted, plated, coated, or other- Automatic sprinkler systems are rec- conditions present. wise altered after leaving the factory. ommended to be inspected, tested, Modified sprinklers must be replaced. and maintained by a qualified Inspec- Sprinklers that have been exposed to tion Service in accordance with local corrosive productsof combustion,but requirem entsand/or national codes. TFP171 Page 8 of 10 2-7/8"DIA. _ 2-7/8"DIA. _ 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8 (73,0 mm) 1/2" (12,7 mm) (15,9±6,4 mm) _ 2_1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) _ 2-1/4" DIA. 1/4" (6,4 mm) / FACE (57,2 mm) MOUNTING / FAC (57,2 mm) 1 MOUNTING SPRINKLER PLATE SPRINKLER PLATE ,----- FITTING FITTING / 1/8" 1/8" (3,2 mm) (3,2 mm) pr j t \ l'E =1_ 1 1777 7. miW\ ,� t SURFACE IP t MOUNTING SURFACE i•�r ii•�� CLOSURE SERIES 1-5/16" (33,3 mm) CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16" (20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 8 FIGURE9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2INCHNPT 2.8 K-FACTOR, 1/2INCHNPT 2-7/8"DIA. _ 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) / FACE (57,2 mm) 1 MOUNTING / FACEOF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / (3,2 m / 1/8" I_ mm) ' T ------- --'1!_ri 1777 7. (3,2 mm) i_ MiliBl / J �� l�_, f \ \ ,,, MOUNTING IV" t MOUNTING SURFACE SURFACE ' _ ' CLOSURE SERIES 1-1/4" (31,8 mm) CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1" (25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2INCHNPT 4.2 K-FACTOR, 1/2INCHNPT TFP171 Page 9 of 10 2-7/8"DIA. 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8 (73,0 mm) 1/2" (12,7 mm) (15,9±6,4 mm) _ 1/4" (6,4 mm) (12,7±3,2 mm) 1/4" 2-1/4" DIA. _ 2-1/4" DIA. (6,4mm) / FACEOF r (57,2 mm) MOUNTING / FACEOF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / 1/8" / 1/8" (3,2 mm) 1 (3,2 mm) A / ► T® - ----4 77 ► T A ni\ ��� �� MOUNTING IIP MOUNTING SURFACE SURFACE/ r / CLOSURE / SERIES 1-1/4" (31,8 mm) CLOSURE SERIES 1-1/4" (31,8 mm) I TY-FRB 3/4"(19,1 mm) TY-FRB 1" (25,4 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2INCH NPT 5.6 K-FACTOR, 1/2INCH NPT 2-7/8"DIA. 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) (57,2 mm) FACEOF MOUNTING FACEOF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" / (3,2 mm) 1 / (3,2 mm) _-etr J� ► 1-*---r J' 177 7 : /7A T�, MOUNTING 'IT / I MOUNTING -- - I SURFACE SURFACE -----.. 1 ---------.. CLOSURE SERIES 1-5/16" (33,3mm) CLOSURE SERIES 1-5/16" (33,3mm) TY-FRB 13/16" (20,6 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 14 FIGURE 15 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2INCH TOTAL ADJUSTMENT STY LE40 RECESSED ESCUTCHEON STYLE30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4INCH NPT 8.0 K-FACTOR, 3/4INCH NPT TFP171 Page 10 of 10 P/N 57 - XXX- X - XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 330 2.8K UPRIGHT(1/2"NPT) TY1131 1 NATURAL B BASS 135 135°F (57°C) 331 2.8K PENDENT(1/2"NPT) TY1231 3 PURE WHITE 1 155 155°F(68°C) POLYESTER(RAL9010) 340 4.2K UPRIGHT(1/2"NPT) TY2131 4 SIGNAL WHITE 175 175°F 79°C POLYESTER(RAL9003) ( ) 341 4.2K PENDENT(1/2"NPT) TY2231 5 JET B LACK 200 200°F(93°C) POLYESTER(RAL9005)2 370 5.6K UPRIGHT(1/2"NPT) TY3131 7 LEAD COATED 286 286°F(141°C) 371 5.6K PENDENT(1/2"NPT) TY3231 9 CHROME PLATED 390 8.0K UPRIGHT(3/4"NPT) TY4131 NOTES: 1. Eastern Hemisphere sales only. 391 8.0K PENDENT(3/4"NPT) TY4231 2. Available in only 2.8K,4.2K,and 8.0K,155°F(68°C) and 200°F(93°C);requires lead time to manufacture. 360 8.0K UPRIGHT(1/2"NPT) TY4831° 361 8.0K PENDENT(1/2"NPT) TY4931` TABLE D SERIES TY-FRB PENDENTAND UPRIGHTSPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty term sand conditions,visit Contact your local distributor for www.tyco-fire.com. availability. When placing an order, indicate the full p roductnam a and Part Num ber(P/N). SprinklerAssemblies with NPT Thread Connections Specify:Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright)Sprinkler(specify)temperature rating, (specify)finish or coating, P/N (specifyfromTable D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N(specify*) Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 "Refer to Technical Data Sheet TFP770 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdal e,PA 194461 Telephone+1-215-362-0700 Copyright©2015 Tyco Fire Products, LP. All rights reserved. t(gco TEFLON is trademark of The DuPont Corporation. Fire Protection Products