Loading...
HomeMy WebLinkAboutF18-0053_approved documents_1534281420.pdf 75 South Frontage Road Fire-Construction Permit 0West, TOWN OF VAIL F18-0053 TOWN Vail,CO 81657 Issued: 08/14/2018 TOWN Or VAIL Office:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 311 BRIDGE ST R(210108279002 R)(210108279002) Unit#:R Parcel Number: 210108279002 Legal Description: Subdivision:HILL BUILDING Unit:R R785474 MAP 02-07-02 R785475 DEC 02-07-02 Contacts Contact Type:Applicant Full Name:SteveAllen Address: 274 Center Drive Glenwood Springs,CO 81601 Phone: 7202190574 Contact Type:Property Owner Full Name:43-45 RIVA RIDGE LLC NORTH BRIDGE VENTURE PARTNERS Address: Phone: None Contractor Contractor Type:Fire Protection Company: Western States Fire Protection Co. State License#: Phone: 303-549-8975 Projecllnformation Project Name:Hill Building Exterior Renovation 2017 Project Description: Install Fire Sprinklers per NFPA 13D and Vail Fire Requirements Fees Paid Account#:001-0000.31111.00-Fire Suppression Permit Fee Fee Amount: $1,793.84 Account#:001-0000.31123.00 Fire Suppression Review Fee Fee Amount: $432.00 Total Paid: $2,225.84 Conditions Issued By:Town of V ailFireand Emergency Services Department NOTICE:By issuance of this Permitthe applicant agrees to complyto all Titles of the Town of Vail Code and all applicable State and Federal law.Failureto do so will void this Permit and the applicant shallforfeit all applicablefees. Hydraulic Summary Job Number:CH0384 NI Report Description:MASTER BEDROOM Job Job Number Circuit Description CH0384 Trevor Storm Job Name: State Certification/License Number 311 Bridge Street 18-S-05209 Address t AHJ Vail,Colorado Vail Fire Address 2 Part Description 81657 311 Bridge Street Address 3 Drawing Name 311 Bridge-FP System Remote Area(s) Most Demanding Sprinkler Data Occupancy Job Suffix 4.9 K-Factor 13.00 at 7.039 Residential Hose Allowance At Source Density Area of Application 0.00 0.10gpm/ft2 900ft2(Actual 195ft2) Additional Hose Supplies Number Of Sprinklers Calculated Coverage Per Sprinkler Part Number Flow(apm) 4 196ft2 AutoPeak Results:Pressure For Remote Area(s)Adjacent To Most Remote Area Left:107.44 7 Thomas M. Coakley, CET Western States Fire Protection Co. NICET Level III Registration#107$52 Sprinkler System Layout Total Hose Streams 0.00 System Flow Demand Total Water Required(Including Hose Allowance) ' 54.04 54.04 Signa .' Maximum Pressure Unbalance In Loops 0.000 Maximum VelocityAbove Ground 19.83 between nodes 14 and 15 Maximum Velocity Under Ground df 1.22 between nodes 1 and 2 Volume capacity of Wet Pipes Volume capacity of Dry Pipes 153.91gal Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin 'art Numbe Name (gpm) (psi) (psi) @° (gpm) (psi) 0 (gpm) (psi) (psi) 1 Water Supply 130.000 45.890 1258.00 129.751 54.04 108.604 21.147 Contractor 411 ' Contractor Number Contact Name Contact Title 2 Trevor Storm Name of Contractor. Phone Extension Western States Fire Protection 303 909-3054 Address 1 FAX 7021 South Tucson Way Address 2 E-mail Centennial,Colorado Trevor.storm@wsfp.us Address 3 Web-Site 80112 ©M.E.P.CAD,Inc. AutoSPRINK2018 v14.2.9.0 7/10/2018 2:56:29PM Page 2 iii Hydraulic Analysis Job Number:CH0384 Report Description:MASTER BEDROOM Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length '--• Route 1 DR 1.0550 13.00 4.77 150 0.037751 0'-4 Pf 0.071 19 33'-8 13.00 4.9 7.039 Sprinkler, 1'-6'% Pe -0.145 18 34'-0 6.965 E(1'-6%) 1'-10%z Pv BL 1.0550 13.00 4.77 150 0.037751 4'-0 Pf 0.151 18 34'-0 6.965 Pe 17 34'-0 7.116 4'-0 Pv BL 1.0550 26.03 9.55 150 0.136386 4'-0 Pf 0.546 17 34'-0 13.03 7.116 Flow(q)from Route 2 Pe 16 34'-0 7.662 4'-0 Pv BL 1.0550 39.54 14.51 150 0.295595 4'-0 Pf 1.182 16 34'-0 13.51 7.662 Flow(q)from Route 3 Pe 15 34'-0 8.844 4'-0 Pv BL 1.0550 54.04 19.83 150 0.526875 26'-4%z Pf 16.755 15 34'-0 14.50 8.844 Flow(q)from Route 4 5'-5 Pe 14 34'-0 25.599 cplg(0'-9%),T(4'-8) 31'-9'% Pv CM 1.0550 54.04 19.83 150 0.526875 12'-7 Pf 12.357 14 34'-0 25.599 10'-10'% Pe 13 34'-0 37.956 4E(1'-6 ),T(4'-8) 23'-5'% Pv CM 1.0550 46.01 16.89 150 0.391279 0'-9'% Pf 2.140 13 34'-0 37.956 4'-8 Pe 12 34'-0 40.096 T(4'-8) 5'-5'%Pv FR 1.0550 46.01 16.89 150 0.391279 0'-0 Pf 1.822 12 34'-0 40.096 4'-8 Pe -4.335 11 24'-0 37.583 T(4'-8) 4'-8 Pv CM 1.0550 46.01 16.89 150 0.391279 9'-0'% Pf 7.177 11 24'-0 37.583 9'-4 Pe 10 24'-0 44.761 2T(4'-8) 18'-4 Pv CM 1.0550 54.04 19.83 150 0.526875 38'-5 Pf 30.872 10 24'-0 8.03 44.761 Flow(q)from Route 5 20'-2 Pe 9 24'-0 75.632 7E(1'-6%),2T(4'-8) 58'-7 Pv CM 1.2910 54.04 13.25 150 0.197123 34'-7 Pf 9.182 9 24'-0 75.632 12-0 Pe 8 24'-0 84.814 T(4'-4%),3E(2'-2),cplg(1'-1) 46'-7 Pv CM 2.0090 54.04 5.47 150 0.022879 1'-9 Pf 0.251 8 24'-0 84.814 9'-2'% Pe 7 24'-0 85.065 T(9'-2%) 10'-11'% Pv FR 2.0090 54.04 5.47 150 0.022879 0'-0 Pf 0.211 7 24'-0 85.065 9'-2'% Pe 6.936 6 8'-11%z 92.212 T(9'-2%) 9'-2'% Pv CM 2.0090 54.04 5.47 150 0.022879 7'-2%z Pf 0.225 6 8'-11'% 92.212 2'-7'% Pe 5 8'-11%z 92.436 E(2'-7%) 9'-10 Pv FR 2.0090 54.04 5.47 150 0.022879 2'-5 Pf 0.055 5 8'-11'% 92.436 Pe 1.049 4 6'-6'% 93.540 2'-5 Pv FR 4.2600 54.04 1.22 120 0.000889 1'-6%z Pf 0.013 4 6'-6'% 93.540 13'-2 Pe 0.660 3 5'-0 94.213 E(13'-2) 14'-8'% Pv FM 4.2600 54.04 1.22 120 0.000889 15'-0 Pf 10.048 3 5'-0 94.213 39'-6 Pe 1.736 2 1'-0 105.998 3E(13'-2),BFP(-10.000) 54'-6 Pv _UG 4.2600 54.04 1.22 120 0.000889 6'-0 Pf 0.005 2 1'-0 105.998 Pe 2.601 1 -5'-0 108.604 Water Supply 6'-0 Pv 0.00 Hose Allowance At Source 1 54.04 Route 2 DR 1.0550 13.03 4.78 150 0.037914 0'-4 Pf 0.189 20 33'-8 13.03 4.9 7.072 Sprinkler, 4'-8 Pe -0.145 17 34'-0 7.116 T(4'-8) 5'-0 Pv _G. Route 3 DR 1.0550 13.51 4.96 150 0.040547 0'-4 Pf 0.202 21 33'-8 13.51 4.9 7.604 Sprinkler, 4'-8 Pe -0.145 16 34'-0 7.662 T(4'-8) 5'-0 Pv Route 4 ©M.E.P.CAD,Inc. NU AutoSPRINK 2018 v14.2.9.0 7/10/2018 2:57:03PM Page 4 iii Hydraulic Analysis Job Number:CH0384 Report Description:MASTER BEDROOM Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length DR 1.0550 14.50 5.32 150 0.046209 0'-4 Pf 0.231 22 33'-8 14.50 4.9 8.758 Sprinkler, 4'-8 Pe -0.145 15 34'-0 8.844 T(4'-8) 5'-0 Pv E. Route 5 FR 1.0550 8.03 2.95 150 0.015480 0'-0 Pf 0.072 24 34'-0 8.03 39.345 Flow(q)from Route 6 4'-8 Pe 4.335 23 24'-0 43.752 T(4.-8) 4'-8 Pv CM 1.0550 8.03 2.95 150 0.015480 52'-8'/z Pf 1.008 23 24'-0 43.752 12'-5 Pe -0.000 10 24'-0 44.761 5E(1'-6'%),T(4'-8) 65'-1'% Pv Route 6 CM 1.0550 8.03 2.95 150 0.015480 57-1 Pf 1.389 13 34'-0 37.956 T(4'-8) 32'-7 Pe 24 34'-0 39.345 4T(4'-8),6E(1'-6'%2) 89'-8'/= Pv Equivalent Pipe Lengths of Valves and Fittings(C=120 only) ` C Value Multiplier= Actual Inside Diameter 487 ValueOfC 100 130 140 150 Schedule 40 Steel Pipe Inside Diameter ) =Factor MultiplyingFactor p 0.713 1.16 1.33 1.51 Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain BaIV Ball Valve DR Drop Discharge gpm BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run O R Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt Total pressure at a point in a pipe DeIV Deluge Valve SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure ata point in a pipe E 90°Elbow UG Underground Pf Pressure loss due to friction between points EE 45°Elbow Pe Pressure due to elevation difference between indicated Eel 11W Elbow points Ee2 22'1/x°Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. qg AutoSPRINK2018 v14.2.9.0 7/10/2018 2:57:03PM Page 5 i Summary Of Outflowing Devices I Job Number:CH0384 31:-/-%• - Report Description:MASTER BEDROOM Actual Flow Minimum Flow K-Factor Pressure Device (gpm) (gpm) (K) (psi) 4, Sprinkler 19 13.00 13.00 4.9 7.039 Sprinkler 20 13.03 13.00 4.9 7.072 Sprinkler 21 13.51 13.00 4.9 7.604 Sprinkler 22 14.50 13.00 4.9 8.758 * Most Demanding Sprinkler Data E,©M.E.P.CAD,Inc. In AutoSPRINK2018 v14.2.9.0 7/10/2018 2:56:48PM Page 3 i Hydraulic Overview \ Job Number:CH0384 C' Report Description:MASTER BEDROO M Job Number Circuit Description CH0384 Trevor Storm Job Name: Phone FAX 311 Bridge Street 303 909-3054 Address 1 State Certification/License Number Vail,Colorado 18-S-05209 Address 2 AHJ 81657 Vail Fire Address 3 Part Description 311 Bridge Street i Density Area of Application 0.10gpm/ft2 900ft2(Actual 195ft2) Most Demanding Sprinkler Data Hose Streams 4.9 K-Factor 13.00 at 7.039 0.00 Coverage Per Sprinkler Number O ropdnklers Calculated 196ft2 4 System Pressure Demand System Flow Demand 108.604 54.04 Total Demand Pressure Result 54.04 @ 108.604 +21.147 (16.3%) Supplies Check Point Gauges art Numb( Name Flow(gpm) HoseFlow(gpm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(gpm) 1 Water Supply 1258.00 130.000 45.890 311 Bridge-FP Water Supply at Node 1 (1258.00,0.00,130.000,45.890) 150 ►' — �),`' 135 Static– Pressure 130.000 120 H =_54.04 @ 108.604 105 . \ • 90 Q — - 75 W System demand curve o_• 60 45 • 1258.00 @ 45.890 1 1 30 15 111 • - r-1-4 alllimulll ll mum!111111111 111 11 11 1 1 II 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 00075010001250 1500 1750 2000 2250 2500 Water flow,gpm L©M.E.P.CAD,Inc. in AutoSPRINK 2018 v14.2.9.0 7/10/2018 2:56:26PM Page 1 6 1-f038y 111 Western States Fire Protection Co.0 Pwtect4t9 (lad Pwfte'4 Flow Test Information Done By: Steve Allen Address: 3/ ( '$(4.510 6k-f-e -1--, Hydrant Location: Same Date & Time: g 19 @ v be ed Static: ) 3 p.s.i. I36—.64-Aq tG Residual: ITh p.s.i. @ 16 ? g.p.m. 5.0 $S Pe5 Observers; 1 Z5-1 Signatur- Print Company rpciA) 0 Bulletin 135 R ev.M ® ModeIF1 Reliable Residential Sprinklers for cri DesignDensity of.05gpmfft2 a Model F1 Res Sprinklers engineered forthe lowestflows to meetthe minimumdesigndensityof.05 gpmfft2 Types: 1. Fl R es30 Pendent • . 2. F1 R es30 Recessed Pendent/F2 • 3. F1 R es30 Recessed Pendent/FP • 4. Fl R es49 Pendent 5. Fl R es49 Recessed Pendent/F1 s 6. F1 R es49 Recessed Pendent/FP F� 7. Fl R es58 Pendent Fl R es30,49,58&76 Fl R es30,49,58&76 8. Fl R es58 Recessed Pendent/F1 Recessed Pendent/F1 Recessed Pendent/FP Fl R es58 HSWX 9. Fl R es58 Recessed Pendent/FP 10. F1 R es76 Pendent 11. F1 R es76 Recessed Pendent/F1 12. F1 R es76 Recessed Pendent/FP 13. Fl R es30 CCP Pendent r 14. Fl R es49 CCP Pendent 15. F1 R es58 CCP Pendent 411;1) • 16. Fl R es76 CCP Pendent 17. F1 R es44 HSW F1 R es30,49,58&76 F1 R es44&58 F1 R es44 SWC 18. Fl R es44 Recessed HSW/F2 CCP Pendent Recessed HSW/F2 19. F1 R es58 HSW 20. Fl R es58 HSWX Horizontal Sidewall sprinklers(Figs. 5,6&7)are equally attrac- 21. KRes58 HSWX tivewhenaboveceiling piping cannot be used. 22. Fl R es58 HSW Recessed HSW/F2 The3mmglass-bulb pendentsprinklers permittheefficient use 23. Fl R es44 SWC of residential watersupplies for sprinkler coverage in residential Listings & Approvals fire protection design. The lowflowF1 R essprinklers arespecially engineered forfast 1. Listed by Underwriters Laboratories Inc.and thermal response to meet the sensitive fire protection applica- UL Certified for Canada (cULus) tion needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heatcauses a sprinkler's Sprinklers for .10 Density: Refer to Bulletin 176 heat-sensitive element,glassbulborlinktoactuate,releasing the UL Listing Category waterway forwaterflowontothe deflector,evenlydistributing the R esidential Automatic Sprinkler discharged waterto control afire. UL Guide Number Technical Data: VKKW • Thermal Sensor: Soldered Element (Link)or Nominal 3mm glass-bulb Patents • Sprinkler Frame : Brass Casting US Patent No. 6,516,893 applies to the Model F1 R es49 • Sprinklers'Pressure Rating: 175 psi &58 Pendent Sprinklers Factory Hydrostatically Tested to 500 psi US Patent No. 7,353,882 applies to Model Fl R es44&58 • Thread Size: 1/2" NPT(R'/2) HSW Sprinklers • K-Factor:3.0(43.2XActual)-F1R es30 Pendent Sprinkler US Patent No. 7,784,555 applies to Model F1 R es44 SWC 4.9(70.6XActual) F1 Res49PendentSprinkler Sprinklers 5.8(83.5XActual)-Fl R es58 Pendent&HSWSprinkler Product Description 7.6(109)(Actual)-F1R es76 Pendent Sprinkler . Model Fl Res Pendent sprinklers (Figs. 1, 2, 3, &4)are fast 4.4(63)(Actual)-F1Res44HSWSprinkler response sprinklers combining excellent durability,high sensitiv- • Density: Minimum 0.05 gpm/ft2 ity glass-bulb and low profile decorative design. The Fl R es Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model F1 R esSprinklers are used for Residential Fire Pro- the onlyrecessed escutcheonsto be used with Model F1 R es tection according to UL 1626 Standard*. For ceiling types: sprinklers. Use of any otherrecessed escutcheon will void all Smooth Flat Horizontal,or beamed,or sloped, in accordance approvals and warranties. For installing Model F1 R esPen- with NFPA13D,13R ,or 13 2013 editions. Be surethatorifice dent sprinklers use only the Model D sprinkler Wrench; for size,temperature rating,deflectorstyleand sprinklertypeare installing Models F1 R es Recessed Pendent, CCP & SWC in accordance with the latestpublishedstandards of The Na- sprinklers use only the Model GFR2 sprinkler wrench; for in- tional Fire Protection Association or the approving authority stalling Model F1 R esRecessed HSW sprinklers use only the having jurisdiction. Model GFR 2Sprinkler Wrench. Use of wrenches other than Installation those specified may damage these sprinklers. Install F1 R es Models F 1 R es sprinklers are to be installed as shown. 44 with a ceiling to deflector distance of 4" 12". Flow arrow Model F1, F2 and FP Escutcheons, illustrated herewith, are on deflector must point away from near wall and"Top" mark- ing must face ceiling. Escutcheon*,Fl or F2,Data: Adjustment "A" Face of fitting to ceiling Type Inch(mm) Inch(mm) Inch(mm) Deflector Distance below bottom of beam Inch(mm) F1 3/4(19.0) Min.Recessed=15/8(41.3) 3/8(9.5) 13/4(44.4) Max.Recessed=7/8(22.2) 11/8(28.6) 1 (25.4) F2 /2(12.7) Min.Recessed=15/8(41.3) 3/8(9.5) 13/4(44.4) Max.Recessed=11/8(28.6) 7/8(22.2) 11/4(31.7) *Note:Escutcheons Fl or F2 may be used with Model Fl R es49,58&76 R ecessedPendent Sprinkler • Model Fl Res 30 Recessed Pendent/F2 • Model Fl Res 30, 49, 58 &76 Pendent • Model Fl Res 49,58 &76 Recessed Pendent/Fl 4— ' .41, '.../ 1 , F1 escutcheon, 3/4" (19mm) adjustment — 2 1/4""HOLE DIA. __ [57.2mm] 1 75/16"DIA. [49.2mm] \ / I rt 7""X 1/2"REDUCER I1J / TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER FACE OF FITTING TO WRENCH BOSS. r —I, 1 CEILING DIMENSION.. �__� 3/8"-1 7/8"(F7 ESCUTCHEON) II ®��d� �/, 1 3/8"-7/8"(F2 ESCUTCHEON) 11s��=,1 lig 4- ADJUSTMENT lml l 1%//O °l1 h%�u�r \ �Q -_ n.% [3.2mm] y y 227/32"DIA . 135x;03 ' r35,40i8 [72.2mm] Fig. 1 Fig. 2 - . • ical Data: F1Res 30 Pendent and Recessed Pendent(SIN R3511) Thread - •.inal Orifice Max.PressureSprinkler Temp.Rating Max.Ambient Temp Actual K Sprinkler Length Size Inch • _ psi(bar) °F °C °F °C Factor Inch(mm) 1/2"NPT2764"(8.2) 155 68 100 38 3.0(43.2) 2.25(57) (R 1/2) 175 79 Ordinary Temp.Ratin• • ermediate Temp.Rating Max.Coverage area Max. Minimum FtxFt(mxm) Spacing FIow(15S°F/6Pressure Flow ° /79°C) ure Top of Inch to Spacing Ft(m) GPM(Umin) PSI(bar) GPM(Umin) PSI(bar Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) 7.0(0,48) 8(30,3) 7.0(0,48) Smoot 'I•s 1'/4 to 4(31.7 to 102) using F2 e . eon. 14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11 (0,76) 10(37,8) 11 (0,76) Beamed Ceilings per NFP' -5 3R 8(2,4) 16 x 16(4,9 x 4,9) 16(4,9) 13 (49) 18.8(1,3) 13(49) 18.8(1,3) or 13 installed in beams 11/4 to 13/4(31.7 to 44.4)using F2 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D 2. Technical Data: F1Res 49 Pendent and Recessed Pendent(SIN R3516) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Pressure Temp.Rating AmbientTemp. K Length Size Inch(mm) psi(bar) °F °C °F °C Factor Inch(mm) 1/2"NPT7/16"(11) 175(12) 155 68 100 38 4.9(70.6) 2.25(57) (R 1/2) 175 79 150 66 Ordinary Temp.Rating Intermediate Temp.Rating I Top of Deflector Minimum Max.Coverage area Max.Spacing (155°F/68°C) (175°F/79°C) Ftx Ft(m x m) Ft(m) Flow Pressure Flow Pressure to Ceiling Spacing GPM(Umin) PSI(bar) GPM(Umin) PSI(bar) Inch(mm) Ft(m) 12 x 12(3,6 x 3,6) 12 (3,6) 13(49) 7.0(0,48) 13(49) 7.0(0,48) Smooth Ceilings 11/4 to 4(31.7 to 102)using F2 escutcheon. HEADS COVERING LESS THAN 130 SQ FT CALCULATED AT 13 GPM FOR A .1 DENSITY 16 x 16 (4,9 x 4,9) 16 (4,9) 13(49) 7.0(0,48) 13(49) 7.0(0,48) Beamed Ceilings per NFPA 8(2,4) 13D,13R or 13 installed in 18 x 18 (5,5 x 5,5) 18 (5,5) 17 (64,3) 12(0,83) 17(64,3) 12(0,83) beams 11/4 to 13/4 (31.7 to 44.4)using F2 escutcheon, 1 20 x 20(6,1 x 6,1) 20(6,1) 20(75,7) 16.7(1,14) 20(75,7) 16,7 (1,14) to 13/4(25.4 to44.4)using F1 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Ordinary Temp.Rating Intermediate Temp.Rating Top of Deflector Minimum Max.Coverage area Max.Spacing (155°F/68°C) (175°F/79°C) Ftx Ft(m x m) Ft(m) Flow Pressure Flow Pressure to Ceiling Spacing GPM(Umin) PSI(bar) GPM(Umin) PSI(bar) Inch(mm) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 15 (57) 9.4(0,65) 15(57) 9.4(0,65) Smooth Ceilings 4 to 8(100 to 203)using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(60,5) 10.6(0,73) 16 (60,5) 10.6(0,73) 4 to 8(100 to 203)using F1 escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 17(64,3) 12.0(0,83) 17 (64,3) 12.0(0,83) Beamed Ceilings per NFPA 13D, 8(2,4) 13R or 13 installed in beams 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 15.0(1,0) 19(72) 15.0(1,0) 41/4 to 8(108 to 203)using F2 escutcheon,4 to 8(100 to 203) 20 x 20(6,1 x 6,1) 20(6,1) 22(83,2) 20.2(1,4) 22(83,2) 20.2(1,4) using F1 escutcheon -chnical Data: F1Res 58 Pendent and Recessed Pendent(SIN R3513) Thread , : ' inal Orifice Max. Sprinkler Max. Actual Sprinkler Pressure Temp Rating AmbientTemp. Length Size Inc ) psi(bar) °F °C °F °C K Factor Inch(mm) 1/2"NPT1/z"(13) 5(12) 155 68 100 38 5.8(83.5) 2.25(57) (R 1/2) 175 79 150 66 Ordinary Te -ating Intermediate Temp.Rating Top of Deflector Minimum Max.Coverage area Max.Spacing (155°F/68°C) (175°F/79°C) Ftx Ft(m x m) Ft(m) Flow Pressure Flow Pressure to Ceiling Spacing GPM(Umin) PSI(bar) GPM Ir PSI(bar) Inch(mm) Ft(m) 12 x 12(3,6 x 3,6) 12 (3,6) 16(61) 7.6(0,53) 16(61) • 0,53) Smooth Ceilings 11/4 to 4(31.7 to 102)using F2 escutcheon. 14 x 14(4,3 x 4,3) 14 (4,3) 16(61) 7.6(0,53) 16(61) 7.6(0,53) •4(25.4 to 102)using Fl escutc . 16 x 16(4,9 x 4,9) 16(4,9) 16(61) 7.6(0,53) 16(61) 7.6(0,53) Beamed Ceili ._ .er NFPA 13D, 8(2,4) 13R or 13 installed in •2.ms 18 x 18(5,5 x 5,5) 18 (5,5) 19(72) 10.8(0,75) 19(72) 10.8(0,75) 11/4 to 13/4 (31.7 to 44.4)usin. F2 escutcheon, 1 to 13/4(25.4 to 20 x 20(6,1 x 6,1) 20(6,1) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 44.4)using F1 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D 3. - . I nical Data: Fl Res 76 Pendent and Recessed Pendent(SIN R7618) Thread mina)Orifice Max. Sprinkler Max. K Sprinkler Pressure Temp.Rating AmbientTemp Length Size Inc .i m) psi(bar) °F °C °F °C Factor Inch(mm) 3/4"NPT17/32"(13.5) 175(12) 155 68 100 38 7.6(109) 2.25(57) (R3/4) 175 79 150 66 Ordina , -mp.Rating Intermediate Temp.Rating Max.Coverage area Max.Spacing (155°F -. (175°F/79°C) Topof Deflectorto Ceiling Minimum FtxFt(mxm) Ft(m) Flow Press - FIowGPM Pressure Inch(mm) Spacing GPM(L/min) PSI(bar) -v in) PSI(bar) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 21 (79,5) 7.6(0,53) 21 (79,5) 7.6(0,53) Smooth Ceilings 41/4 to 8(108 to 203)using F2 escutcheon. 14 x 14(4,3 x 4,3) 14 (4,3) 21 (79,5) 7.6(0,53) 21 (79,5) 7.6(0, _ 4 to 8(100 to 203)using F1 es eon. 16 x 16(4,9 x 4,9) 16(4,9) 21 (79,5) 7.6(0,53) 21 (79,5) 7.6(0,53) Beamed -. •is per NFPA 8(2,4) 13D,13R or 13 in : -d in 18 x 18(5,5 x 5,5) 18(5,5) 21 (79,5) 7.6(0,53) 21 (79,5) 7.6(0,53) beams 41/4 to 8(108 to •• s- ing F2 escutcheon,4 to 8(100 20 x 20(6,1 x 6,1) 20(6,1) 23(87,1) 9.2(0,63) 23(87,1) 9.2(0,63) to 203)using F1 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D • Model F1 Res 30, 49, 58 & 76 CCP Pendent* • Model F1 Res 30, 49, 58 & 76 Recessed Pendent/FP •Il .. . au! *Not listed for corrosion resistance. FP push-on/thread-off escutcheon 2 5/8"[66.7mm] DIA. 2 5/8" DIA. [66.7mm] 2 5/16" DIA. HOLE IN CEILING —HOLE IN CEILING [58.7mm] CUP -----+:1-:), 2 5/16" DIA. k,_4_`__-s [58.7mm] T ------__ CUP_ 1"x1/2" REDUCER r `], CUP \ / I IT 1 I 1" X 1/2" REDUCER CEILING �illll III 1 1/4"[31.5mm] \ / II[ c�ll I 1 .r II II MAX. FACE OF FITTING T TO FACE OF CEILING L } ;����i�� DIMENSION CEILING I I 1 1/2" [38.1mm] MAX. �� i/ "C' ♦ I I;I tlU IlFACE OF FITTING "A" �A'� .,, "e» 1,,,� TO FACE OF CEILING COVER ADJUSTMENT -- ' D MENSION HEIGHT 0 FP ADJUSTMENT 1/2"[13mm] MAX. Ve 9 I I 3 5/16"DIA. - I I 7 35FG04E [84.1 mm] Mo 113 Fl RES 30, 49, 58 & 76 CCP PEND. Fl RES 49 PENDENT/FP Fig. 3 Fig. 4 Note: TheF1Res 76will u sea 1"x 3/4"reducer. CCP Cover Plate Data: FP Escutcheon Data: „C„ ..B„ Deflector Distance below bottom "A" Deflector Distance below bottom Cover Adjustment CCP Height FP Position Inch(mm) Inch(mm) of beam Inch(mm) of beam Inch(mm) Inch(mm) 1/2(12.7) 15/16(24) 1 (13)-1 (25.4) Max.Recessed 7/16(11) 1/2(12.7) 5/16(7.9) 3/4(19) 1/2(13)-1 (25.4) Min.Recessed 15/16(24) 1 (25.4) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. 4. - nical Data: F1Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) 'mina) Max. CCP Assembly Max. Sprinkler Thread K Orihc- Pressure Temp.Rating Ambient Temp. Length Size Factor Inch(mm) ps • °F °C °F °C Inch(mm) 1/2"NPT 27/64"(8.2) 175 (12) 13 57 100 38 3.0(43.2) 2.25(57) (R 1/z) Ordinary Temp.Ra • Minimum Max.Coverage area Max.Spacing (155°F/68°C) Top of Deflectorto Ceiling Ft x Ft(m x m) Ft(m) Flow Pressure Inch(mm) Spacing GPM(Umin) PSI(bar) Ft(m) 12 x 12(3,6 x 3,6) 12 (3,6) 8(30,3) 7.0(0,48) Smooth Ceilings 1/z to 1 (13 to 25.4)usin• .. '. 1/2 to 1 (13 to 25.4)using FP escutcheon. Beamed Ceilings per NFPA 13D,13R or 13 installed in 4) 14 x 14(4,3 x 4,3) 14(4,3) 11 (37,8) 13.4(0,92) beams 1/2 to 1 (13 to 25.4)using CCP. 1/2 to 1 (13 to 25.4)using FP escutcheon. For Ceiling types refer to NFPA 13, 13R or 13D hnical Data: F1Res 49 CCP Pendent and Recessed Pendent/FP (SIN 3516) CCP Thread Orific inal Max. Max. Assembly Ambient K Sprinkler Size Inch ' essure Temp. Temp. Factor Length psi : -r) Rating Inch(mm) (mm) ° °C °F °C /z"NPT 7/16"(11) 175 (12) 135 100 38 4.9(70.6) 2.25(57) (R 1/2) Max.Coverage Ordinary Te = •ating Minimum Max.Spacing (155°F/68°C) Top of Deflector to Ceiling area Ft(m) Flow Pressure Inch(mm) Spacing Ft x Ft(m x m) GPM(1../min) PSI(bar) Ft(m) 12 x 12 (3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48) Smooth Ceilings 1/2 to 13 to 25.4)using 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) CCP. Y to 1 (13 to 25.4)using FP esc .•eon. 16 x 16(4,9 x 4,9) 16(4,9) 14(53) 8.2(0,56) Beamed Ceilings per NFPA 13D,13R. 3 8(2,4) installed in beams 1/2 to 1 (13 to 25.4)using 18 x 18(5,5 x 5,5) 18(5,5) 18 (68,1) 13.5(0,93) CCP. 1/2 to 1 (13 to 25.4)using FP escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 20(75,7) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D hnical Data:F1Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Nominal Max. CCP Assembly Max. Sprinkler Thread ; ',ice Pressure Temp.Rating AmbientTemp. K Length Size Inch(m psi(bar) °F °C °F °C Factor Inch(mm) Y"NPT (R 1/2) 1/2"(13) 1 2) 135 57 100 38 5.8(83.5) 2.25(57) Max.Coverage Ordinary ..Rating Minimum Max.Spacing (155°F/68° Top of Deflector to Ceiling area Ft(m) Flow Pressure Inch(mm) Spacing FtxFt(mxm) GPM(Umin) PSI(bar) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6(0,53) 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6(0,53) Smooth Ceilings 1/2 to 1 (13 to 2 .• ing CCP. Y to 1 (13 to 25.4)using FP escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 16(61) 7.6(0,53) Beamed Ceilings per NFPA 13D,13R or 13 ins- .. in beams 1/to 8(2,4) 1 (13 to 25.4)using CCP. 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 10.8(0,75) 1/2 to 1 (13 to 25.4)using FP escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 22(83,3) 14.4(1,0) For Ceiling types refer to NFPA 13, 13R or 13D 5. -chnical Data: F1Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Nominal Max. CCP Assembly Max. Sprinkler ThreadK t.% 'ice Pressure Temp.Rating Ambient Temp. Factor Length Inch(m psi(bar) °F °C °F °C Inch(mm) 3/4"NPT17/32"(13.5) 1 ) 135 57 100 38 7.6(109) 2.25(57) (R3/4) 150 66 Max.Coverage Ordinary e Rating Minimum Max.Spacing (155°F/68°C) Top of Deflector to Ceiling area Ft(m) Flow Pressure Inch(mm) Spacing Ft x Ft(m x m) GPM(L/min) PSI(bar) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 21 (79,5) 7.6(0,53) 14 x 14 (4,3 x 4,3) 14(4,3) 21 (79,5) 7.6(0,53) Smooth Ceilings 1/to 1 (13 to 25.4 . '••CCP. 1/2 to 1 (13 to 25.4)using FP escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 21 (79,5) 7.6(0,53) Beamed Ceilings per NFPA 13D,13R or 13 instal-. '.beams 1/2 8(2,4) to 1 (13 to 25.4)using CCP. 18 x 18 (5,5 x 5,5) 18(5,5) 22(83,3) 8.4(0,58) 1/2 to 1 (13 to 25.4)using FP escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 25(94,6) 10.8(0,74) For Ceiling types refer to NFPA 13, 13R or 13D • Model Fl Res 44&58 HSW r ' k FACE OF FITTING TO WALL DIMENSION 1 1/4"MIN. 2 1/4"HOLE DIA. [31.8mm] A [57.2 mm] f7/g CEILING TO [3.2mm] DEFLECTOR 7"X 1/2"REDUCER DIMENSION f 1 .� • Model Fl Res 44 &58 Recessed HSW/F2 gi ; IRI.' /O 7 15/76""D — — I .i i.� N_` [49.2mm] n'" I o,'/ 2 27/32""DIA. inn / , , r /,4 _. [72.2mm] 1 1 , , TURN COLLAR UNTILTIGHT AGAINST � i WRENCH BOSS.SPRINKLER \`! ■ 35Fcos—a 1/2"[13mm] ADJUSTMENT F1 RES 58 & 44 HSW/F2 F2 escutcheon, Fig. 5 1/2" (13mm) adjustment Technical Data: F1Res 44 HSW & HSW/F2 (SIN R3531) Escutcheon,F2, Data: Nominal Max. Sprinkler Max. Sprinkler Face of Fitting Thread Ambient K Adjustment Size Orifice Pressure Temp.Rating Temp. Factor Length Type Inch(mm) to wall Inch(mm) psi(bar) °F °C °F °C Inch(mm) Inch(mm) /z"NPT3/8"(10) 175(12) 155 68 100 38 4.4(63) 2.45(62) F2 '/2(13) ahs-11/.6 (R 1/2) 175 79 150 66 (4.7-17.4) 6. Ordinary Temp.Rating Intermediate Temp.Rating Max.Coverage area Max.Spacing (155°F/68°C) (175°F/79°C) Top of Deflector to Minimum Ft Ft(m x m) Ft(m) Flow Pressure Flow Pressure Ceiling Spacing GPM(L/min) PSI(bar) GPM(L/min) PSI(bar) Inch(mm) Ft(m) 12 x 12(3,6 x 3,6) 12 (3,6) 12(45,4) 7.5(0,52) 12(45,4) 7.5(0,52) 14 x 14(4,3 x 4,3) 14(4,3) 14(53,0) 10.2(0,71) 14(53,0) 10.2(0,71) 16 x 16(4,9 x 4,9) 16 (4,9) 16(60,6) 13.3(0,92) 16(60,6) 13.3(0,92) 4 to 6(100 to 152); 1/2(13)recessed 16 x 18(4,9 x 5,5) 16 (4,9) 18(68,1) 16.8(1,16) 18(68,1) 16.8(1,16) using F2 escutcheon 18 x 18(5,5 x 5,5) 18 (5,5) 19(72,0) 18.7(1,29) 19(72,0) 18.7(1,29) 16 x 20(4,9 x 6,1) 16 (4,9) 23(87,1) 27.4(1,89) 23(87,1) 27.4(1,89) 8(2,4) 12 x 12(3,6 x 3,6) 12 (3,6) 14(53,0) 10.2(0,71) 14(53,0) 10.2(0,71) 14 x 14(4,3 x 4,3) 14(4,3) 16 (60,6) 13.3(0,92) 16(60,6) 13.3(0,92) 6 to 12(152 to 305); 16 x 16(4,9 x 4,9) 16 (4,9) 17 (64,4) 15.0(1,04) 17(64,4) 15.0(1,04) 1/2(13)recessed using F2 escutcheon 16 x 18(4,9 x 5,5) 16 (4,9) 20(75,7) 20.7(1,43) 20(75,7) 20.7(1,43) 16 x 20(4,9 x 6,1) 16 (4,9) 23(87,1) 27.4(1,89) 23(87,1) 27.4(1,89) For Cciling typc3 rcfcr to NFPA 13, 13R or 13D - . nical Data:F1Res 58 HSW & HSW/F2(SIN R3533) Escutcheon,F2, Data: k ominal Max. Sprinkler Face of Fitting Max. Sprinkler Adjustment Thread 0 ''ce Pressure Temp.Rating Ambient K Length Type Inch mm to wall Size •si bar F °C °TF °C Factor Inch ( ) Inch(mm) ( ) (bar) ° ° ° ( ) 1/2 3/16-11/16 (R 1/2) 1/2"(13) 175(1 175 79 150 66 5.8(83.5) 2.45(62) (4.7-17.4) •rdinary Temp.Rating Intermediate Temp.Rating Max.Coverage area Max.Spacing 155°F/68°C) (175°F/79°C) Top of Deflector to Minimum Ft x Ft(m x m) Ft(m) Flo ' Pressure Flow Pressure Ceiling Spacing GPM(L/min PSI(bar) GPM(L/min) PSI(bar) Inch(mm) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 16(60,6) 7.: 1,53) 16(60,6) 7.6(0,53) 14 x 14(4,3 x 4,3) 14(4,3) 18(68,2) 9.7(0,69) 18(68,2) 9.7(0,69) 4 to 6(100 to 152); 16 x 16(4,9 x 4,9) 16 (4,9) 21 (79,5) 13.2(0,91) 21 -• 5) 13.2(0,91) 1/2(13)recessed using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 25(94,7) 18.6(1,28) 25(94,7) 18.6(1,28) 16 x 20(4,9 x 6,1) 16 (4,9) 29(109,8) 25.0(1,73) 29(109,8) 25.0 73) 8(2,4) 12 x 12(3,6 x 3,6) 12(3,6) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 14 x 14(4,3 x 4,3) 14(4,3) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 6 to 1 152 to 305); 1/2(13)r-.-ssed 16 x 16(4,9 x 4,9) 16 (4,9) 26(98,4) 20.1 (1,39) 26(98,4) 20.1 (1,39) using F2 escut •-on 16 x 18(4,9 x 5,5) 16 (4,9) 31 (117,4) 28.6(1,97) 31 (117,4) 28.6(1,97) For Ceiling types refer to NFPA 13, 13R or 13D 7. • Model Fl Res 44 SWC* v______ "Not listed for corrosion resistance. 4"to 12" [101.60mm To 1 1/4"[31.75mm]Maximum 304.80mm] Face Of Fitting PUSH ON COVER, THEN To Wal/Dimension TURN TO ADJUST UNTIL r TIGHT AGAINST WALL. 1"X 1/2"Reducer d al Recommended i4 !le Wall Hole 2 5/76" ', ,n i//ii. 2 5/8" [58.74mm]�� --- ja;=i„I4;• 3 5/16” Y ' !�.. [66.68mm] Dia. i Dia. `Inui ? [84.74mm] rj i TURN COLLAR UNTIL RET AGAINST SPRINKLER '^—.INKLER WRENCH BOSS. 1 21/32" [42.07mmJ 135F007 1/2"[72.70mm] Adjustment F1 RES 44 SWC Fig. 6 echnical Data:F1Res 44 SWC I SIN R3531) Cover Max. Thre.• Nominal Max. Temp. Ambient K Sprinkler Size Orifice Pressure Rating Temp. Factor Length •ch(mm) psi(bar) °F °C °F °CInch(mm) 1/2"NPT 3/8"(10 175(12) 135 57 100 38 4.4(63) 2.45(62) (R'/2) Ordinary Temp.Rating Top of Deflector to Minimum Max.Coverage area Max.Spa ' g (155°F/68°C) Ft x Ft(m x m) Ft(m) Flow Pressure Ceiling Spacing • (L/min) PSI(bar) Inch(mm) Ft(m) 12 x 12(3,6 x 3,6) 12 (3,6) 13 (A° ) 8.7(0,60) 14 x 14(4,3 x 4,3) 14(4,3) 14(53,0) 10.2(0,71) 4 to 6(100 to 152); 16 x 16(4,9 x 4,9) 16 (4,9) 17 (64,3) 15.0 1) 1/2(13)recessed using F2 escutcheon 16 x 18(4,9 x 5,5) 16 (4,9) 19(71,8) 18.7(1,13) 16 x 20(4,9 x 6,1) 16 (4,9) 23(87,1) 27.4(1,89) 8(2,4) 12 x 12(3,6 x 3,6) 12 (3,6) 14(52,9) 10.2(0,71) 14 x 14(4,3 x 4,3) 14(4,3) 15 (56,7) 11.7 (0,81) 6 to 12(152 to 305); 1/2(13)recessed 16 x 16(4,9 x 4,9) 16 (4,9) 18(68,1) 16.8(1,16) using F2 escutcheon 16 x 18(4,9 x 5,5) 16 (4,9) 20(75,6) 20.7(1,43) For Ceiling types refer to NFPA 13, 13R or 13D 8. -chnical Data: F1Res 58 HSWX (SIN RA3533) Nominal Max. Sprinkler Max. Sprinkler Sprinkler Th =.d Ambient K Size Orifice Pressure Temp.Rating Temp. Factor Length Identification ch(mm) psi(bar) °F °C °F °C Inch(mm) Number(SIN) Bulb 1/2"NPT 1/2"(13) 175(12) 155 68 100 38 5.8(83.5) 2.45(62) R A3533 (R'/) 175 79 150 66 •rdinary Temp.Rating Intermediate Temp.Rating Max.Coverage area Max.Spacing 155°F/68°C) (175°F/79°C) Top of Deflector to Minimum Ft Ft(m x m) Ft(m) Flo Pressure Flow Pressure Ceiling Spacing GPM(L/min) PSI(bar) GPM(L/min) PSI(bar) Inch(mm) Ft(m) 18 x 20(5,5 x 6,1) 18 (5,5) 30(114) 26.: 85) 30(114) 26.8(1,85) 20 x 20(6,1 x 6,1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 4 to 6(100 to 152); 16 x 22(4,9 x 6,7) 16 (4,9) 33(125) 32.4(2,23) 33 = 32.4(2,23) 1/2(13)recessed using F2 escutcheon 16 x 24(4,9 x 7,3) 16 (4,9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4(3,75) 42(160) 52.4( , ) 8(2,4) 18 x 20(5,5 x 6,1) 18 (5,5) 35(133) 36.4(2,5) 35(133) 36.4(2,5) 16 x 22(4,9 x 6,7) 16 (4,9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 6 to 12 to 305); 1(13)rec-- ed 16 x 24(4,9 x 7,3) 16 (4,9) 42(160) 52.4(3,6) 42(160) 52.4(3,6) using F2 escutch-:4 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9(4,34) 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D • Model Fl Res 58 HSWX(Bulb) 4 FACE OF FITTING TO - - ...„ )1..,Ili WALL DIMENSION 1 11/16" MIN. 2 1/4" HOLE DIA. [31.8mm] ---- �1/8," 'A" .. [57.2mm] y --.-1/8" [3.2mm] CEILING TO DEFLECTOR :7 s r r+ , . 7"X 1/2" REDUCER DIMENSION 4- - / % I �)7_ �,.� 1 ,4 1 75/16" DIA. / I I.. `--' [49.2mm] i n 111111117,1' % 2 27/32" DIA. nn Ilio [72.2mm] L_omL ,_-j; L .• I TURN COLLAR UNTIL �� • TIGHT AGAINST SPRINKLER `\`! Model KRes58 HSWX(Link) WRENCH BOSS. Li f 1/2"[73mm] . . 135FG08 ADJUSTMENT I Fl RES 58 HSWX Fig. 7 - t r r ,, 4, • 9. ' -chnical Data: KRes58 HSWX (RA3593) Nominal Max. Max. Sprinkler Sprinkler •read Ambient K SiOrifice Pressure Temp. Factor Length Identification - Inch(mm) psi(bar) °F °f. Inch(mm) Number(SIN) Link 1/2"NPT 1/2 13) 175(12) 100 3815.8(83.5) 2.45(62) RA3593 (R 1/2) Ordinary Temp.Rating Top of Deflector to Minimum Max.Coverage area Max.Spacin• (165°F/74°C) Ft Ft(m x m) Ft(m) Flow Pressure Ceiling Spacing GP min) PSI(bar) Inch(mm) Ft(m) 18 x 20(5,5 x 6,1) 18 (5,5) 29(109) 25(1,72) 20 x 20(6,1 x 6,1) 20(6,1) 30(114) (1,85) 4 to 6(100 to 152); 16 x 22(4,9 x 7,3) 16 (4,9) 33(125) 32.4(2, ' /(13)recessed sing F2 escutcheon 16 x 24(4,9 x 7,3) 16 (4,9) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4(3,75) 8(2,4) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4(2,5) 16 x 22(4,9 x 6,7) 16 (4,9) 38(144) 42.9(2,96) 6 to 12(152 to 305); 1/2(13)Recessed 16 x 24(4,9 x 7,3) 16 (4,9) 42(160) 52.4(3,6) using F2 escutcheon 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model Fl R es30, 49, F1 R es58, Fl R es 76 and Fl Res ter seal assembly shall consist of a Teflon* coated Bel- 44 Sprinklers should be inspected and the sprinkler sys- leville spring washer with top-loaded extruded or cold tern maintained in accordance with NFPA 25, 13, 13D, head cup with 3 mm glass bulb containing no plastic and 13R. Do not clean sprinkler with soap and water,Am- parts, and having a temperature rating of [155°F (68°C)] monia or any other cleaning fluids. R emovedust by using [175°F (79°C)]. Sprinklers shall have a nominal K-factor a soft brush or gentle vacuuming. Remove any sprinkler of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome- which has been painted (other than factory applied) or plated] [White Polyester] [Special finish- specify]. R esi- damaged in any way.A stock of spare sprinklers should dential pendent sprinklers shall be R eliableModel Fl R es be maintained to allow quick replacement of damaged or 30, 49 & 58, SIN R 3511, R 3516& R 3513(Bulletin 135). operated sprinklers.Prior to installation,sprinklers should Model F1 Res 49 & 58 Recessed Pendent/F1, remain in the original cartons and packaging until used. Model F1 Res 30, 49 & 58 Recessed Pendent/ This will minimize the potential for damage to sprinklers F2,Model F1 Res 30,49&58 Recessed Pendent/ that could cause improper operation or non-operation. FP Model F1 Res 30, 49 & 58 Pendent Sprinklers shall be [cULus Listed] [New York City MEA Sprinkler Specifications Approved(258-93-E)] low flow residential recessed pen- Sprinklers shall be [cULus Listed] [New York City MEA dent sprinklers engineered to provide a minimum design Approved(258-93-E)] low flow residential pendent sprin- density of 0.05 gpm/ft2 over the listed coverage area. klers engineered to provide a minimum design density of Listed flows as specified by the manufacturer's technical 0.05 gpm/ft2 over the listed coverage area. Listed flows data sheets are to be used. R esidential sprinklers shall as specified by the manufacturer's technical data sheets be installed in conformance with the manufacturer's in- are to be used. R esidential sprinklers shall be installed stallation guidelines and the applicable installation stan- in conformance with the manufacturer's installation guide- dard. Deflector-to-ceiling distance listing shall be 1" to 8" lines and the applicable installation standard. Deflector- maximum, only for F1R es49. Sprinkler frame and deflec- to-ceiling distance listing shall be 1" to 8" maximum, only tor shall be of bronze frame construction having a 1/2" NPT for F1R es 49. Sprinkler frame and deflector shall be of thread. Water seal assembly shall consist of a Teflon* bronze frame construction having a '/2" NPT thread. Wa- coated Belleville spring washer with top-loaded extruded *DuPont R egisteredTrademark 10. or cold head cup with 3 mm glass bulb containing no leville spring washer with top-loaded extruded or cold plastic parts, and having a temperature rating of [155°F head cup with 3 mm glass bulb containing no plastic (68°C)] [175°F (79°C)]. Sprinklers shall have a nomi- parts, and having a temperature rating of [155°F (68°C)] nal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [175°F (79°C)]. The solder element (Link) version, the [Chrome-plated] [White Polyester] [Special finish— spec- water seal consist of a cap with a bellville spring washer ify]. R ecessed escutcheon assembly shall be a steel, and a temperature rating of 165°F (74°C). The recessed two-piece escutcheon [with 1/2" adjustment (Model F2)] assembly forthe HSWX (Bulb & Link) should be a steel [with 3/4" adjustment (Model F1)] [of push-on and thread two pieces escutcheon with 1/2" adjustment (Model F2) off design with '/2" adjustment (Model FP)]. Standard fin- standard finish should be Bright Chrome and white paint- ish shall be [brass][bright chrome] [white painted]. R esi- ed. The Fl R es 58 HSW is also available with low lead dential recessed pendent sprinklers shall be R eliable frame. F1 R es58 HSW and HSWX sprinklers shall have a [Model Fl R es30,49&58 R ecessedPendent/F1] [Model nominal K Factor of 5.8 and Fl R es44 a nominal K factor Fl R es30,49&58 R ecessedPendent/F2][Model F1 R es of 4.4. Standard finish: [Bronze][Chrome-plated] [White 30, 49 & 58 Recessed Pendent/FP]SIN R 3511, R 3516& Polyester][Special finish—specify]. R esidential horizontal R 3513(Bulletin 135). sidewall sprinklers shall be R eliable Model F1 R es44, Fl Model Fl Res 30, 49 & 58 CCP Pendent Res58, F1 Res58 HSWX & Model KRes58HSWX, SIN (Concealed) R 3531,R A3533& R A3593(Bulletin 135). Sprinklers shall be [cULus Listed] [New York City MEA Model Fl Res 44 Recessed Approved (258-93-E)] low flow residential concealed Horizontal Sidewall Sprinkler sprinklers engineered to provide a minimum design den- Use description for the Model F1 R es44 horizontal side- sity of 0.05 gpm/ft2 over the listed coverage area. Listed wall sprinkler with the following modifications: R eplace flows as specified by the manufacturer's technical data "horizontal sidewall sprinkler" with "recessed horizontal sheets are to be used. R esidential sprinklers shall be in- sprinkler." Add: R ecessedescutcheon assembly shall be stalled in conformance with the manufacturer's installa— tion guidelines and the applicable installation standard. F2).Standard finish shall be [brass][bright chrome] [white Sprinkler frame and deflector shall be of bronze frame painted] [Special finish— specify]. R esidential recessed construction having a 1/2" NPT thread. Water seal as horizontal sidewall sprinklers shall be R eliable Model Fl sembly shall consist of a Teflon*coated Belleville spring R es44/F2,SIN R 3531(Bulletin 135). washer with top-loaded extruded or cold head cup with 3 Model Fl Res 76 Pendent mm glass bulb containing no plastic parts, and having a Sprinklers shall be [cULus Listed] low flow residential temperature rating of 155°F (68°C). Cover plate assem- pendent sprinklers engineered to provide a minimum bly shall consist of a brass cover plate and copper alloy design density of 0.05 gpm/ft2 over the listed coverage retainer flange. Method of attaching the cover plate to the area. Listed flows as specified by the manufacturer's sprinkler cup shall be a push-on and thread-off design technical data sheets are to be used. R esidential sprin- allowing a '/2" cover plate adjustment. Cover plate tem- klers shall be installed in conformance with the manufac- perature rating shall be 135°F (57°C). A plastic protec- turer's installation guidelines and the applicable installa- tive cap shall be provided and factory installed inside the tion standard. Sprinkler frame and deflector shall be of sprinkler cup to protect the sprinkler from damage, which bronze frame construction having a 3/4" NPT thread. Wa- could occur during construction before the cover plate ter seal assembly shall consist of a Teflon* coated Bel- is installed. Standard cover plate finish: [White] [Custom leville spring washer with machined or cold head cup with Color— specify]. ]. Concealed pendent sprinklers shall 3 mm glass bulb containing no plastic parts, and having be R eliable Model F1 R es30, 49 & 58 CCP,SIN R 3511, a temperature rating of [155°F (68°C)] [175°F (79°C)]. R 3516& R 3513(Bulletin 135). Sprinklers shall have a nominal K-factor of 7.6. Standard Model Fl Res 44, Fl Res 58 Horizontal finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- Sidewall, Fl Res 58 HSWX & KRes58 HSWX cial finish— specify]. R esidential pendent sprinklers shall Residential Sprinkler Specifications be Reliable Model F1 Res76, SIN R7618(Bulletin 135). Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. R esiden- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a'/2" NPT thread. Water seal assembly shall consist of a Teflon*coated Bel- *DuPont R egisteredTrademark 11. Model F1 Res 76 Recessed Pendent/F1, Model F1 Res 76 Recessed Pendent/F2, a temperature rating of 155°F (68°C). Cover plate assem- Model F1 Res 76 Recessed Pendent/FP bly shall consist of a brass cover plate and copper alloy Sprinklers shall be [cULus Listed] low flow residential retainer flange. Method of attaching the cover plate to the recessed pendent sprinklers engineered to provide a sprinkler cup shall be a push on and thread off design minimum design density of 0.05 gpm/ft2 over the listed allowing a 1/2" cover plate adjustment. Cover plate tem- coverage area. Listed flows as specified by the manu- perature rating shall be 135°F (57°C). A plastic protec- facturer's technical data sheets are to be used. R esiden tive cap shall be provided and factory installed inside the tial sprinklers shall be installed in conformance with the sprinkler cup to protect the sprinkler from damage, which manufacturer's installation guidelines and the applicable could occur during construction before the cover plate installation standard. Sprinkler frame and deflector shall is installed. Standard cover plate finish: [White] [Custom be of bronze frame construction having a 34" NPT thread. Color—specify]. ]. Concealed pendent sprinklers shall be Water seal assembly shall consist of a Teflon*coated Bel- Reliable Model Fl R es76 CCP,SIN R 7618(Bulletin 135). leville spring washer with machined or cold head cup with Finishes c1) 3 mm glass bulb containing no plastic parts, and hav- Standard Finishes ing a temperature rating of[155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard Sprinkler F1, F2,FP Cover Plates finish: [Bronze] [Chrome-plated] [White Polyester] [Spe Escutcheons cial finish— specify]. R ecessed escutcheon assembly Bronze Brass White Painted shall be a steel, two-piece escutcheon [with '/" adjust Chrome Plated Bright Chrome Plated Chrome White and Black White Painted ment (Model F2)] [with 3A" adjustment (Model F1)] [of Polyester(2)Coated push-on and thread off design with '/2" adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] Special Application Finishes [white painted]. R esidential recessed pendent sprinklers Sprinkler Fl, F2,FP shall be Reliable[Model Fl R es 76 Recessed Pendent/ Escutcheons F1] [Model F1 R es 76 Recessed Pendent/F2] [Model F1 Electroless Nickel PTFE(Teflon®))2) Electroless Nickel PTFE(TeflorP) R es76 Recessed Pendent/FP]SIN R 7618(Bulletin 135). Bright Brass Bright Brass Model F1 Res 76 CCP Pendent(Concealed) Black Plated Black Plated Black Paint Black Paint Sprinklers shall be [cULus Listed] low flow residential Off White Off White concealed sprinklers engineered to provide a minimum Chrome Dull Chrome Dull design density of 0.05 gpm/ft2 over the listed coverage (')Other finishes and colors are available on special order. area. Listed flows as specified by the manufacturer's Consult factory for details. technical data sheets are to be used. R esidential sprin (2)cULus listed corrosion R esistant Note: Paint or any other coating applied over the factory finish will void klers shall be installed in conformance with the manufac- all approvals and warranties. turer's installation guidelines and the applicable installa- Ordering Information tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3A" NPT thread. Wa- Specify: ter seal assembly shall consist of a Teflon* coated Bel- 1. Sprinkler Model leville spring washer with machined or cold head cup with 2. Sprinkler Type 3 mm glass bulb containing no plastic parts, and having 3. Temperature R ating 4. Sprinkler Finish 5. Escutcheon Finish 6. Cover Plate Finish "DuPont R egisteredTrademark The equipment presented in this bulletinis to be installed in accordanceAiththe latestpublished Standards of the National FireProtection Association,Factory Mutual Research Corporation,or othersimilarorganizations and also with the provisions of governmental codes or ordinances wheneverapplicable. Products manufactured and distributed by Reliable have been protecting life and property for over90 years,and are installed and serviced by the most highly qualified and reputable sprinklercontractors located throughout the United States,Canadaand foreign countries. Manufactured by Reliable Automatic Sprinkler Co.,Inc. V. Recycled (800)431 1588 Sales Offices . Paper Reliabli (800)848 6051 Sales Fax (914) 829 2042 Corporate Offices R evisionlines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.06/15 P/N 9999970235 Bulletin 006 Rev.K February 2017 Reliable Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler cULus Listed Product Features • cULus Listed as Residential Sprinklers -�" .— • Push-On cover plate installation • Low water flow requirements Product Description Model RFC30 Model RFC43 Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- '.-_t;• cordance with UL 1626. Model RFC30, RFC43,and RFC49 sprinklers have a 165°F 11111 • (74°C) temperature rated fusible-link operating element. Model RFC49 Model RFC58 Model RFC58 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link op- erating element. Sprinklers with a 165°F (74°C)temperature rating are ordinary temperature classification and should be used with a 135°F (57°C)temperature rated cover plate. Sprinklers with a 212°F (100°C)temperature rating are inter- mediate temperature classification and should be used with a 165°F (74°C)temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30,RFC43,and RFC49 sprinklers allow 1/2" (••••.' (13 mm)of cover plate adjustment. Model RFC58 sprinklers allow 3/4"(19 mm)of cover plate adjustment. Model RFC cover plates are available in a variety of finishes Solid Perforated as listed in Table H. In addition, Model RFC cover plates may be ordered as either traditional solid cover plates or Model RFC Cover Plate perforated cover plates. Table A Nominal K-Factor Max.Coverage Area Sprinkler Sprinkler Model gpm/psiu2(I/min/bat-1'2) ft x ft(m x m) Identification Num ber(SIN) RFC30 3.0(43.2) 14 x 14 (4.3 x 4.3) RA0611 RFC43 4.3(62) 20 x 20(6.1 x 6.1) RA0612 RFC49 4.9(70.6) 20 x 20(6.1 x 6.1) RA0616 RFC58 5.8(84) 20 x 20(6.1 x 6.1) RA0613 www.reliablesprinkler.com Model RFC30 Residential Sprinkler SIN RA0611 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) Threads:1/2"NP Tor ISO 7-1 R1/2 Nominal K-Factor:3.0(43.2 metric) Sensitivity , _ Max.Working Pressure:175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) Temperature Rating Material Specifications 165°F (74°C)sprinkler Therm alSensor:Nickel Alloy Solder Link 135°F (57°C)cover plate Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate Yoke:Brass Alloy Model RFC cover plate ,V Sealing Assem bly:Nickel Alloy with PTFE .1.7"--- Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model FC Pins:Stainless Steel Deflector:Bronze Alloy Listings and Approvals e ,. Cup:Steel cULus Listed Bottom View ' , Model RFC30 Sprinkler Com ponents and Dimensions Figure 1 2-5/16"(58 mm) Threads Dia. Body Cup ~-.44L_ _ f _ M_ Tower ' - 1-3/4"(44 mm)+/-1/4"(6 mm) - Fusible Link .�� Nominal face of fitting to ceiling ° ��� ��a,' '..a,' Deflector(retracted) i'v—r v—v 3/16" 5 mm ) Pin(extended) - Deflector(extended) I 1 Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC30 Sprinkler Hydraulic Design Criteria Table B Minim urn Flow and Residual Pressure Max.Coverage Area Flow Pressure ft.x ft. gpm psi (m x m) (Wm in) (bar) 12 x 12 9 9.0 (3.6 x 3.6) (34) (0.62) 14 x 14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table B above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.K ��';��'� Page 2 of 7 February 2017 www.reliablesprinkler.com Model RFC43 Residential Sprinkler SIN RA0612 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) , '11111k Threads:1/2"NP Tor ISO 7-1 R1/2 Nominal K-Factor:4.3(62 metric) Sensitivity Nk Max.Working Pressure: 175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) . r Temperature Rating Material Specifications 165°F (74°C)sprinkler 4/#1i Therm alSensor:Nickel Alloy Solder Link 135°F (57°C)cover plate Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate oil Yoke:Brass Alloy Model RFC cover plate Sealing Assem bly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Sprinkler Wrench t Towers:Copper Alloy Model FC Pins:Stainless Steel . ''.'• Deflector:Bronze Alloy Listings and Approvals Bottom View f 6t Cup:Steel cULus Listed Model RFC43 Sprinkler Corn ponents and Dim ensions Figure 2 2-5/16"(58 mm) Threads Dia. Body Cup — = S t .W_4.1 Tower 1-3/4"(44 mm)+/-1/4"(6 mm) � Fusible Link Nominal face of fitting to ceiling-irAill �� ��� Deflector(retracted) `ate' '`ate' 3/16" 5 mm ) ----- 77x7//, Pin(extended) I I I I Ji Deflector(extended) ; .rtr„-, Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC43 Sprinkler Hydraulic Design Criteria Table C Minim urn Flow and Residual Pressure Max.Coverage Area Flow Pressure ft.x ft. gpm psi (m x m) (Wm in) (bar) 12 x 12 12 7.8 (3.6 x 3.6) (45) (0.54) 14 x 14 13 9.1 (4.3 x 4.3) (49) (0.63) 16 x 16 13 9.1 (4.9 x 4.9) (49) (0.63) 18 x 18 18 17.5 (5.5 x 5.5) (68) (1.21) 20 x 20 21 23.8 (6.1 x 6.1) (79) (1.64) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table C above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.K ��'- ° Page 3 of 7 February 2017 www.reliablesprinkler.com Model RFC49 Residential Sprinkler SIN RA0616 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) Threads:1/2"NPTor ISO 7-1 R1/2 Nominal K-Factor:4.9(70.6 metric) Sensitivity ,,,"".,,,o," Max.Working Pressure:175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) f' ., Temperature Rating ' '. 4 ''' Material Specifications 165°F (74°C)sprinkler = •! Therm alSensor:Nickel Alloy Solder Link 135°F (57°C)cover plate 11 Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate Yoke:Brass Alloy Model RFC cover plate Sealing Assem bly:Nickel Alloy with PTFE _ Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model FC Pins:Stainless Steel , Deflector:Bronze Alloy Listings and Approvals Bottom View " _;'41 ,1' Cup:Steel cULus Listed ax,;� N Model RFC49 Sprinkler Com ponents and Dim ensions Figure 3 -2-5/16"(58mm) y Threads Dia. Body Cup � � _= f � _ -- Tower ) 1-3/4"(44 mm)+/-1/4"(6 mm) Fusible Link ?`r ) Nominal face of fitting to ceiling I. ��� %' � �' Deflector(retracted) r r=%+ - I —v—'+_ 1 r 3/16"(5 mm) Pin(extended) MI ► Deflector(extended) j Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC49 Sprinkler Hydraulic Design Criteria Table D Minim urn Flow and Residual Pressure Max.Coverage Area Flow Pressure ft.x ft. gpm psi (m x m) (Wm in) (bar) HEADS CALCULATED FOR A .1 DENSITY - VARIES DEPENDING ON COVERAGE AREA 18 x 18 17 12.0 (5.5 x 5.5) (64.3) (0.83) 20 x 20 20 16.7 (6.1 x 6.1) (75.7) (1.15) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table D above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.K ��';��'� Page 4 of 7 February 2017 www.reliablesprinkler.com Model RFC58 Residential Sprinkler SIN RA0613 Technical Specifications Sensitivity Style:Flat Concealed Pendent Fast-response Threads:1/2"NP Tor ISO 7-1 R1/2 :" Nom inal K-Factor:5.8(84 metric) Temperature Ratings Max.Working Pressure:175 psi(12 bar) Ordinary: -*- Min. Min.Spacing:8 ft.(2.4 m) 165°F (74°C)sprinkler , '',l'o it- 135°F (57°C)cover plate Material Specifications Intermediate: i I. a i/� Therm alSensor:Nickel Alloy Solder Link 212°F (100°C)sprinkler Sprinkler Body:Brass Alloy 165°F (74°C)cover plate • Levers:Bronze Alloy . Yoke:Brass Alloy Cover Plate `` . z R Sealing Assem bly:Nickel Alloy with PTFE Model RFC Cover P late Load Screw:Bronze Alloy -- Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model FC Deflector:Chrome Plated Bronze Alloy / �'� Cup:Steel Listings and Approvals Bottom View; ,e cULus Listed r Cover Plate Finishes (See Table H) Model RFC58 Sprinkler Corn ponentsand Dim ensions Figure 4 2-5/16"(58 mm) Dia. Threads Body Cup s� �wI ss Tower �— � l , Fusible Link 1 1-7/8"(48 mm)+/-3/8"(9 mm) ,f Nominal face of fitting to ceiling IIiI1 Deflector(retracted) 11144-7 ' `—r _ \\\ I _ _ 17/////////// r 3/16"(5 mm) Pin(extended) Il """` -- Il i �1 Deflector(extended) � 'i' Fi Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC58 Sprinkler Hydraulic Design Criteria Table E Minim urn Flow and Residual Pressure Max.Coverage Aream Flow Pressure ft.x ft. gpm psi (m x m) (Wm in) (bar) 16 x 16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18 x 18 18 9.6 (5.5 x 5.5) (68.1) (0.66) 20 x 20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table E above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.K ��';��'� Page 5 of 7 February 2017 www.reliablesprinkler.com Cover Plate Finishesi'> Table H Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Custom Color Clad(3) Paint(2) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi-gloss,unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side.Cover plates are not listed or approved as corrosion resistant.Stainless steel clad cover plates are not available perforated. Installation Dimensions TableJ Recommended Min.to Min.to Max. Cover Plate Cover Plate Max. Face Dropped Deflector Cover Hole Diameter Cover Plate Sprinkler Diameter Adjustment of Fitting to Distance below Model Plate inch in Ceiling inch Ceiling(1) Ceiling Temperature Model (mm) (mm) (mm) inch inch Rating (mm) (mm) RFC30 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F RFC43 RFC (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC49 135°F2 RFC58 RFC 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) (84) (67) (19) (38 to 57) (6 to 25) or 165°F3 (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up.Verify dimensions based on fitting and thread sealing method prior to installation.A 1/2"x 1/2" brass nipple extension(Reliable P/N 6999991900)is available where necessary for replacement of existing sprinklers. 2. For use with 165°F(74°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F(38°C). 3. For use with 212°F(100°C)temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F(66°C). Inst.Ilatu®�n Model RFC series sprinklers are intended to be installed in ac- Donot exceed the maximum recommended torque. Exceeding cordance with NFPA 13, NFPA 13R, or NFPA 13D,as well as the the maximum recommended torque may cause leakage or im- requirements of applicable authorities having jurisdiction. Mod- pairment of the sprinkler. Use care when inserting or removing el RFC series sprinklers must not be installed in ceilings with the wrench from the sprinkler to avoid damage to the sprinkler. positive pressure in the space above.Ensure that the 4 slots in the cup are open and unobstructed following installation.Model Install the cover plate by hand by pushing the cover plate into RFC series sprinklers are shipped with a protective cap that the cup and turning the cover in the clockwise direction until it should remain on the sprinkler until installed.The protectivecap is tight against the ceiling. should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. /41"Is I ication Model RFC series sprinklers are installed with the Model FC Model RFC series sprinklers are intended for installation where wrench.The use of any other wrench to installed Model RFC se- residential sprinklers are permitted or required by NFPA 13, ries sprinklers is not permitted and may damage the sprinkler. NFPA 13R, and NFPA 13D.The sprinklers are concealed pen- Temporarily remove the protective cap during installation of the dent residential sprinklers. sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body.Do not wrench any other part of the Model RFC 30, RFC43,and RFC49 sprinklers are available in sprinkler/cup assembly.The Model FC wrench is designed to ordinary temperature classification for installation where the be turned with a standard 1/2" square drive.Tighten the sprin- Maximum Ceiling Temperature does not exceed 100°F (38°C). kler into the fitting after applying a PTFE based thread sealant Model RFC58 sprinklers are available in either ordinary or in- to the sprinkler's threads.Recommended installation torque is 8 termediate temperature classification for installation where the to 18 ft/lb(11 to 24 N/m). Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (66°C), respectively. Bulletin 006 Rev.K �e';ab'� Page 6 of 7 February2017 www.reliablesprinkler.com Wrench S Model FC Maintenance Guarantee Model RFC series sprinklers should be inspected and the For the Reliable Automatic Sprinkler Co.,Inc. guarantee,terms, sprinkler system maintained in accordance with NFPA 25. Do and conditions,visit www.reliablesprinkler.com. not clean sprinklerswith soap and water,ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace Patents any sprinkler cover plate assembly which has been painted (other than factory applied)or damaged in any way.A stock of Model RFC30,RFC43,RFC49,and RFC58 sprinklers are spare sprinklers should be maintained to allow quick replace- covered by U.S. Patent No. 9,248,327 and U.S. Patent No. ment of damaged or operated sprinklers. Prior to installation, 7,275,603. sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to Model RFC30 and RFC43 sprinklers are additionally covered sprinklers that would cause improper operation or non-oper- by U.S. Patent No. 8,776,903. ation. Ordering Information Listings and Approvals Specify the following when ordering. Listed by Underwriters Laboratories, Inc. and UL Certified for Sprinkler Canada(cULus) • Model (RFC30,RFC43,RFC49,RFC58) UL • Temperature Rating Listing Category Cover Plate • ModelRFC • Temperature Automatic Sprinkler Rating UL Guide Number • Finish(See Table H) Sprinkler Wrench • Model FC VKKW z CD CO CO COO N Bulletin 006 Rev.K �e1i��1e Page 7 of 7 February 2017 www.reliablesprinkler.com ES-F-880V SPECIFICATION SHEET /Fffff 9/0 /Fffff 9/0 • RiEXISTING �q5® MasterSenes® 880V Reduced Pressure Zone Assemblies 'r- Size:21/2" - 10" (65mm- 250mm) The FEBCO MasterSeries°880V Reduced Pressure ZoneAssembl iesare designed for use in health hazard applications.Standard orientation is inlet flowverticalup,outletflowvertical down.Vertical orientation is inletand ; outlet fl owvertical up. Pressure —Temperature - Temperature Range: 32°F to 140°F(0°C to 60°C) Max.Working Pressure: 175psi(12.1 bar) HydrostaticTest Press: 350psi(24.1 bar) • Materials Main ValveBody: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external MODEL 880VREDUCED PRESSURE Z ONEASSEMBLY AWWAC550-90 (Shown in vertical orientation) ShutoffValves: NRS and OS&Y resil ientwedge gate valvesAWWAC509 Trim: Bronze Elastomer Discs: EPDM . Y. Spring: Stainlesssteel Approvals— Standards . r te. -1;-00.4op: • ANSI/AWWA(C511-89) • Approved by the Foundation for Cross-Connection Control and Hydraulic �� Research at the Universityof Southern California. O • D Approved 1013 B64.4 _v. — MODEL 880VREDUCED PRESSURE ASSEMBLY * Less gate not FM approved. Less gate not UL Classifiedunless instal led (Shown in standard orientation) with UL Listed gate valves. Models U.S.Patent No.4,989,635•U.S.Patent No.5,107,888 ValveSetterwith MJ x MJ, MJ x FL,or FL x FL ends U.S.Patent No.5,385,166•U.S.Patent No.5,226,441 U.S.Patent No.5,392,803•U.S.Patent No.5,503,176 UL/FM 0S&Y RW Gate Valves Rel iefValveAir Gap Drain Funnel Wye Strainer End Connections: FI angedANSI B16.1 Class 125 IMPORTANT:INQUIREWITH GOVERNINGAUTHORITIES FOR LOCALINSTALLATION REQUIREMENTS Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative FEBCO product specifications in U.S.customary units and metric are approximate and are provided for reference only. For precise mea- surements,pl ease contact FEBCO.FEBCO reserves the right to change or modify product design,construction,specifications,or material s without prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previouslyor subse- quently sold. Model 880V/ Materials of Construction O47.1 cam ■o■ m O O se O eOOO m 0 am IN CD m 2.� VO O mm ® ■u■ 46, . \ '.I ee — sa./\ ` 4 Ilk ,,-,s woxv e 1-101111111 11O '� . iE i i /i o ma 00 r y------ 4„, cem , sINI ---- • 4,—�7 • • sr -4,-....4.-11 m� ��li 111 C) •c__„„/ I ( ( _.,....," •� ( . © Allam r .il °'- (( © �1�i, ReliefValve Detail m mm 6000000 10"(250mm)Disc Assembly 0 mom COO 4' ?ice�9�, ■i�= �� Ib�e iir ars '�..: 111 0000� �oo �• O CD ifaiLm.tm 0_ 9 .41:, -,011A%,,, O ID ID ®CUD® m 043) mCM® # DESCRIPTION MATERIAL # DESCRIPTION MATERIAL # DESCRIPTION MATERIAL 1 Body A536GR65-45-12 14 FlangeGasket Rubber/Fabric 36 AdaptorPlate Alloy 2 Coverlst Check A536 GR 65-45-12 15 Bearing Socket Acetal Resin 37 Sm.Diaphragm Nitrile ASTM D2000 2.1 0-Ring EPDM ASTM D2000 16 Hex Jam Nut SS 38 Retainer Alloy 2.2 Capscrew PI atedSteel 17 Washer SS 38.1 SI ipRing Acetal Resin 2.3 Hex Nut PI atedSteel 18 Fl angeBol t PI atedSteel 39 Fl ovA/asher Acetal Resin 2.4 Expansion Pin SS 18.1 Fl angeNut PI atedSteel 40 Bal Valve Alloy 2.5 Cover2nd Check A536 GR 65-45-12 20 R.V.Cover Al I oy 41 Nipple Brass 3 Seat Ring B584 Alloy C83600 20.1 BI eedScrew SS 42 GateValve AWWA C509 3.1 Gasket EPDM ASTM D2000 20.2 Gasket HDPE 43 Bulkhead Fitting Alloy 4 Arm B584 Alloy C83600 21 R.V.Body Alloy 43.1 Bulkhead Fitting Alloy 4.1 Bushing Swg Pin Acetal Resin 22 CoverBolt SS 45 Gasket EPDM ASTM D2000 4.2 Swing Pin SS 23 Elbow A536 GR 65-45-12 45.1 Gasket EPDM ASTM D2000 5 Retaining Clip SS 24 RVMtgBolt PlatedSteel 47 Nut Alloy 5.1 Hairpin Cotter SS 24.1 Washer-RV PI atedSteel 50 Sensing Line SAE Hydraulic Hose 6 CheckDisk EPDM Coated GR,45 25 RVMtgBolt PlatedSteel 51 Street Elbow Alloy Seat Disk Ductile Iron w/SS Stem 27 Lrg.Diaphragm Nitrile ASTM D2000 60 Identification PI ate Al I oy 6.1 Disk Hol der110") 28 Button A240304 SS 62 Drive Screw SS 6.2 Disk Retainer(l0") 28.1 Flow Screw Acetal Resin 70 Clamp(880V) AMA C606 6.3 Capscrew(101 29 RV Spring SS 7 Load Pin SS 30 Stem-RV Acetal Resin 9 Spring Stem SS 31 Main Guide-RV Alloy 9.1 Elastic StopJam Nut SS 31.1 0-Ring-RV FDAEPDM 10 Spring 1st Check SS 32 Seat Disc-RV EPDM ASTM D2000 10.1 Spring 2nd Check SS 33 LowerGuide Acetal Resin 11 Spring Guide SS 34 Seat Disc Alloy 12 UprSpringRetnr Alloy 34.1 0-Ring FDAEPDM 12.1 Bushing-Spr.Stem Acetal Resin 35 0-Ring Acetal Resin 13 Pivot Bearing Alloy 35.1 Back-Up Ring EPDM ASTM D2000 Model 880V Model 880V Standard Orientation Vertical Orientation ----c 4V 1-L '.. j' 1012 F FEBCO , = It '1 = F FE= _ �I- - = • l Ali C :1:::ii qAi�=A C s::11:�U i IreT VIII __ M MI -.% I'" -..: r I Itivi r tivisi t(IP m D . L. ...m..-- ►! �� fit 4—H - G A ° .-`L � GF B B 1-III 111-111 'Hair II lII II�;,III-111 II,;,III . lyzY 0J 0,P ---/--t- .51 0 t j _____} : 4 c. g'L: 7 OP \ 1 j ( C ] o 0 e ° Note:The Model 880V is shipped in the standard(N- Shape)orientation as shown above. ReliefValveDetail NRS Side View Rel iefshipped on right side(shown)field reversible to Ieftside. . E IBM E 1a= 1:111111•61 . 100 1 11 ilillOgi A Fo ;"ii=: Vfe4- - , a p. P.411kArIN 4—4 15/16 3 1/2 —> Dimensions—Weights Size:212"-10"(65-80mm) SIZE(DN) DIMENSIONS WEIGHT A B C D ENRS El OS&Y* F G H J K L M NRS OS&Y in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 211 65 121/2 318 253/4 654 241/4 616 415/6 125 12% 321 16% 416 16% 422 61/4 159 51/2 140 31 89 13% 346 71/4 184 27/ 692 210 95 220 99.8 3 80 121/2 318 253/4 654 243/4 629 51/26 138 121/8 327 221/4 565 16% 422 61/4 159 51/2 140 33/4 95 141/8 359 71/4 184 281/4 718 280 127 290 131.5 4 100 14 356 271/2 708 263/4 680 69/26 167 143/8 365 231/4 591 173/4 451 7 178 6 152 412 114 151/2 394 71/4 184 31 787 320 145 350 158.8 6 150 16 406 321/4 819 321/4 819 89/26 218 181/8 497 301/8 765 214/i 548 8 203 71/2 191 51 140 18% 473 91/2 241 371/4 946 480 218 530 240.4 8 200 1812 470 371 953 363/8 924 99/26 243 231/2 597 373/4 959 241/8 632 91/4 235 83/4 222 63/4 172 203/4 527 101/4 260 411/2 1054 810 367 880 399.2 10 250 21 533 421 1080 403/4 1035 111/2 292 271/2 699 48 1219 271/2 699 10 254 93/4 248 8 203 24 610 111/2 292 48 1219 1350 612 480 671.3 *OS&Y OPEN Weights do not incl uderisers or optional valvesetter. Note:Dimensions shown are nominal.Allowances must be made for normal manufacturing tolerances. Referto Specification Sheet SS VS for detail son valvesetter. Typical Installation Standard orientation(Model 880V) Vertical orientation(Model 880V) 1 18"min t (450mm) Y 18"min _ (450mm) Ali 18"min NV .,. I�1 i 8"min —.- /_. (00mm)i FEBC+� �1, I I (450mm) W. 8"min iii �i� I ~7 =# (200mm) FEBCO 1 18"min :1 II. 4,__ ��".�,., 8„min �� �.� :.I) ) ,E a IuuILmm) � , .. (450mmr 1 %-i _ Flow 4"min 4"min Pipe Support (100mm) (18”with Air Gap Drain, (furnished by customer) ;, ,;, refer to local code) for valve weight only. 711T1iiiii IIIIIIIIEIIIII IlWllilll NI m—= Optional Valve Milar =iii =iiiii Setter w.. e, . 41"..::. ,. Flow Recommended minimum cl earancesfrom permanent structures for ease of test- ing and maintenance are shownon above drawings. Capacity kPa psi 21/2'(65mm) kPa psi 6"(150mm) 110 16 124 18 H 97 14 - - - B ti 110 16 ti 83 12 ti = 97 14 B- 69 10 - A_ 0 83 12 0 a 55 8 a 69 10 = 41 6 s 55 8 28 4 41 6 14 2 28 4 0 200 400 600 800 1000 1200 1400gpm 0 50 100 150 200 250 300 gpm 0 760 1520 2280 3040 3800 4540 5300 Ipm 0 190 380 570 760 950 1140 Ipm kPa psi 3"(80mm) kPa psi 8"(200mm) 124 18 138 20 110 16 A— _ 124 18 A- 9714 y 110 16 S N _ N 97 14 � O 83 12 B o 83 12 ' a 69 10 Tc 69 8 s 55 8 = L" 55 8 41 6 — - 41 6 28 4 28 4 0 50 100 150 200 250 300 350 400 450 gpm 0 500 1000 1500 2000 2500 3000 gpm 0 190 380 570 760 950 1140 1330 1520 1710 Ipm 0 1900 3800 5680 7560 9500 11350 Ipm kPa psi 4"(100mm) kPa psi 10"(250mm) 124 18 138 20 A y ti 110 16 _ 110 16 A— • 97 14 B Ln 83 12 B_ H 83 12 O 69 10 0 a• 55 8 a 555 8 = 41 6 L. L. 28 4 28 4 0 0 14 2 0 100 200 300 400 500 600 700 gpm 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 gpm 0 380 760 1140 1520 1900 2280 2660 Ipm 0 1900 3800 5680 7560 9500 11350 13250 15140 17030 18900 Ipm A-Verticalorientation The 6"and 10"flow curves(B-standard orientation) B-Standard orientation include the FEBCO valve setter model 611. frEs'cO/ CERF@ia A Division of Watts Water Technologies, Inc. USA: 4381 N.Brawley•Ste.102•Fresno,CA•93722•Tel.(559)441-5300•Fax:(559)441-5301 •www.FEBCOonline.com Canada: 5435 North Service Rd.•B urlington,ONT. •L7L 5H7•Tel.(905)332-4090•Fax:(905)332-7068• www.FEBCOonline.ca ES-F-880V 0708 ©FEBCO,2007 Bulletin 425 Rev.E co ® Reliable9.7 ReIiabIa Riser— Res lu entlai iser—Residential m Reliable Riser-Residential 1" (25mm), 1'/2" (40mm), and 2" (50mm)sizes. For use in NFPA 13D and 13R Residential Systems Features: 1. Stainless Steel body construction. Fig.1 BaseTrim 2. All brasstrim. 3. Factory ass embled. 4. Factory press uretested at 200 psi.(13.8 bar). 5. Choice of trim: Basic Trim(Fig.1). Basic Trim with Pressure Relief Kit(Fig.2). 041 Basic Trim with Testand Drain Valve(Fig.3). Basic Trim with Testand Drain Valve and Pressure Relief Kit(Fig.4). 6. Choice of mounting options: Fig.2 BaseTrim with PressureRelief H Supply/Systemlines support. Kit El Support Bracket(to stud)(Figs.5&6). Reces s edor Flush mount(to wood panel) (Fig.7). P11.1111..1 7. NPT(female x female)or tapered met- ric(female x female)connections. 8. Slim design allows for easy installation within 2" x 4"on 16" centers wood frame construction. 9. Dedicated cULus Listed and ULC Listed Wa- ter Flow Detector ass uresoptimum s ens itivity. Water Flow Detector is factory installed with Fig.3 BaseTrim with Testand Drain a metallic,weatherproof cover.Triggeringflow Valve rate is 4(15)GPM(LPM)to 10(38)GPM(LPM). Approvals &Listings 1. Lis ted by Underwriters Laboratories Inc.and ULC Lis ted. 2. NYC MEA 255-93-E Fig.4 BaseTrim with Testand Drain Valve&Press ureRelief Kit Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford,New York 10523 Optional Trims-Technical Data: Basic Trim with Bas is Trim with Test Basic Trim with Testand Description Basic Trim Press ureRelief Kit and Drain Valve Drain Valve Take Out &Press ureRelief Kit Dimension Dimensions Weight* Dimensions Weight* Dimensions Weight* Dimensions Weight* Manifold A B Lbs A B Lbs A B Lbs A B Lbs Size: inch inch (kgs) inch inch (kgs) inch inch (kgs) inch inch (kgs) inch (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) P 11 8a%4 7.3 13% 11 8.7 11 14% 9.0 15 14% 10.6 8% (25mm) (279) (222) (3.32) (343) (279) (3.95) (279) (362) (4.09) (381) (362) (4.82) (210) 1%" 11 9% 8.3 13% 11% 10.5 11 14% 9.7 15 14% 11.2 81/4 (40mm) (279) (235) (3.77) (343) (292) (4.77) (279) (375) (4.41) (381) (375) (5.09) (210) 2" 11 9% 8.8 13% 12 11.1 11 15% 10.5 15 15% 12.2 8% (50mm) (279) (248) (4.00) (343) (305) (5.05) (279) (387) (4.77) (381) (387) (5.55) (210) *Support Bracket Kit(optional)-1 lb(0.45 kg) All Reliable Ris ershave a 1"NPT drain port. Bas icTrim with Pres sire Relief Kit Ras icTrim with Test and Pr-eh Pres sire Relief Kit B elRlcpe B sa KaomGauge 'i .i� Kw wit, Q Mantly System aa:er 0 MiM 1 pie Ewen A —i�(50 lir 1�111�1 --� c 1 It=-01c 1 CICI•y-,ail CIL ( ) I�� (Take-Out) � ��1 Take-Out 11 '--. 4 b 1 tll- S*mrk ura�n .aivare scppiv varve w.. Eder F. (Contact R a tuns,25resaVAC s.0A®24voc) wat.r ria«on.m« (Contact Ratings:+One 125.0 VAC 2.50.e24v0c) Fig.5 Product Description: The Reliable-Risers come factory as s embledwith all of ®1W' (40 mm)cas t,non-welded s tainles ss teel body the neces s aryacces 5 oriesfor a cost effective,yet corn- with 1%"female NPT or ISO7-Rc1.5-11 threaded end plete ris ers olution. connections. Reliable-Risers are[UL Lis ted][ULC Lis ted][NYC Ap- ®2"(50 mm)cas t,non-welded,stainlesssteelbody with proved MEA 258-93-E]for horizontal or vertical ins Calla- 2"female NPT or ISO7-Rc2-11 threaded end connec- tions as a one-piece,factory assembled unit for use in tions. NFPA 13D and 13R res identials ys tems.The risermani- All of these manifold sizes have cast-on lettering that fold as s emblys hall cons is tof a(choos e one): clearly identifies the manifold's pipe size,flow direction, ®1"(25 mm)cast,non-welded stainleswteelbody with UL Listing/ULC Listing,and the testend drain outlet. A 1"female NPT or ISO7-Rc1-11 threaded end connec- built-in drain port is included to permit hydrostatic testing tions. without draining the a ys tern.The ass emblyhas a work- 2. ing pressure rating of 175 psi(12.1 bar). Cas t-in mount- Installation: ing holes are provided for reces s edor flus h mounting to 1. Ins tall the manifold with the flow arrow pointing to- a wall. Forstudmounting,a support bracket is available wards SYSTEM side us ing threaded connections. that is s pecificallydes igned for the castmounting holes. 2. Connect a 1" NPT drain line.Ens urethe drain Ball All of the trim variations include brass components,a Valve is in the CLOSED position. cULus Lis ted 300 psi water pres s uregauge, and a 250 3. Place the s prinklers ys temin s ervice. psi UL Lis ted/ULC Lis ted Waterflow Detector.This Water- flow Detector comes factory installed with a weatherproof Caution: (outs ide)cover. Automatic s prinkler s ys temshaving non-f ire protection connection(permitting continual water flow)require di- Trim Descriptions electric fittings,according to NFPA 13 sect.4-6,when ®Bas is Trim dis s imilarmetal piping materials are joined. Residential ris ermanifold ass emblytrim s hall include a cULus Lis ted pres s uregauge, a drain valve,and Note: dedicated waterflow detector containing two s ets of Useanon-hardening pipe joint compound,or tape. SPDT(Form C)contacts,having an electrical rating of 10A @125/250 VAC/2.5 A @ 24 VDC.Triggering —a 1/2" W M.GAP FOR waren ROW Mo1G10e flow rate is 4(15)GPM(LPM)to 10(38)GPM(LPM). COVER Reuo.(rrp NN AL1 uAwrOIDS) ®Basic Trim with Pres sureRelief Kit — Residential ris ermanifold ass emblytrim s hall include a cULus Lis ted pres s uregauge, a drain valve,and � ®�I� dedicated waterflow detector containing two sets of till SPDT(Form C)contacts,having an electrical rating of 10A @125/250 VAC/2.5 A @24 VDC. Triggering flow rate is 4(15)GPM(LPM)to 10(38)GPM(LPM). suPPOR.VRcxn MOUNT •• Pressure relief valve kit s hall be provided to maintain —sro° ERALRCT CLERK systenpressuresbelow 175 psi(12.1 bar). Arrr FACE DF ['Basic Trim with Test and Drain Valve Residential ris ermanifold ass emblytrim s hall include Fig.6 a cULus Lis ted pres s uregauge, a Testand Drain valve,and a dedicated waterflow detector contain- ing two s ets of SPDT(Form C)contacts,having an WOOD PANEL .LASrIC SPACERS electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM)to 10(38)GPM(LPM). The tes t orif ice s ize for the Tes t and Drain assemblyshall be** omm�� MOE :<�■1m�1,,,4 i **(Choose one) �1•u El 3/8"(10 mm) ir1 ® 7/16"(11 mm) 5 ['Basic lmm) °TrimwthTest and Drain Valve & -- - PressureRelief Kit rc)II V"�s Residential ris ermanifold ass emblytrim s hall include a cULus Lis ted pres s uregauge, a Testand Drain valve,and a dedicated waterflow detector containing RECESSED OR FLUSH MOUN CEO two sets of SPDT(Form C)contacts,having an elec- trical rating of 10A @125/250 VAC/2.5 A @24 VDC. Fig.7 Triggering flow rate is 4(15) GPM(LPM)to 10(38) GPM(LPM).Pressure Relief Kit s hall be provided to maintain systempressured elow 175 psi(12,1 bar). 3. Ordering Information: Residential Riser Part Number Code Key 1N B 0 1M T38 1 1.5N T716 2 1.5M — T12 — 3 2N 2M B=Bas icTrim Ass embly 0=Assembly withoutPressure ReliefKit T38=Bas icTrim Ass emblyuith 3/8"(10mm) WaterDetector-UL&FM Approved 1N=1"(25mm)NPTThreaded Ends Ass embly Orif.Test and Drain Valve 1=Ass emblywith Pressure ReliefKit 1M=1"(25mm)Metric Threaded Ends Ass embly T716=Bas icTrim Ass emblya6h 7/16"(11mm) WaterDetector-UL&FM Approved 1.5N=1-1/2"(40mm)NPTThreaded Ends Ass embly Orif.Test and Drain Valve 2=Assembly withoutPressure ReliefKit 1.5M=1-1/2"(40mm)Metric Threaded Ends Ass embly T12=Bas icTrim As s emblywith 1/2"(15mm) WaterFlow Detector-ULC Approved 2N=2"(50mm)NP Threaded Ends Ass embly Orif.Test and Drain Valve 3=Ass emblyvith Pressure ReliefKit 2M=2"(50mm)Metric Threaded Ends Ass embly WaterFlow Detector-ULC Approved Example #1: 1.5N—B— 1 (1-1/2"(40mm)Residential Ris erAs s emblywith NPT Female Inlet and Outlet Threads,Bas ic Trim with ins tailed Pres- s ureRelief Kit). Example #2: 2M— T12—0 (2"(50mm)Residential Ris erAs s emblywith Metric Female Inlet and Outlet Threads,Bas ic Trim with Test and Drain Valve having a 1/2"Diameter TestOrifice.) Also, If Required: Description Part Number Pressure Relief Kit(For Basic Trim) 98020076 Pressure Relief Kit(For Bas ic Trim with Tes Land Drain Valve) 6501203551 Support Bracket Kit 6899190001 Waterflow Detector(RFDTHN) 96556910 Waterflow Detector ULC(RFDTHANA) 96556914 Paddle Tree-Waterflow Detector 96556911 The equipment presented in this bulletin is to be installed inaccordancewiththelates tpublis hedStandards of The National Fire Protection Association,Factory Mutual Research Corporation,or others imilartxganizations and als owiththe provis ions obovemmental codes or ordinances wheneveepplicable. Products manufactured and distributed byReliablehavebeenprotecting lifeand propertyforover90years,andare installed and serviced by the most highly qualified and reputable s prinklecontractors located throughout the United States,Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co.,Inc. ®Recycled Rel (800)431-1588 Sales Offices Paper iable (800)848-6051 Sales Fax Revis ionlines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Eu.Printed in U.S.A.12/15 P/N9999970348 NI BCD www.nibco.com AHEAD OF THE FLOW® Revised 5/2/2007 300 lb. WWP Bronze Ball Valves Dezincification Fire Protection Valve • Threaded or Grooved Body Style • Full Port Design 1" - 2" • Resistant Standard Port Design 21/ • Accepts Internal Supervisory Switches --- 4300 PSI/20.7 Bar Non-Shock Cold Water CONFORMS TO MSS SP-110 • FM APPROVED • UL LISTED FOR INDOOR AND OUTDOOR SERVICE • CALIFORNIA STATE FIRE MARSHAL LISTING NO. 7770-1243:103 APPROVED BY NEW YORK CITY M.E.A. 218-04-E WITH APPROPRIATE NYC INDICATOR. • 0"`� KT-505-W-8 MATERIAL LIST Threaded PART SPECIFICATION 1111166._ 10 1. Body BronzeASTM B 584 Alloy C84400 2. Ball Chrome Plated Brass ASTM B 124 Alloy C37700 3. Seat Ring Carbon-filled TFE KG-505-W-8 4. Thrust Washer ReinforcedTFE Grooved 5. Stem BronzeASTM B 371 Alloy C69430 0 6. Stem 0-Ring Nitrile an - 3.84 CI 7. Retaining Washer Brass o M 8. Retaining Ring Steel o o 9. Ground Wire Screw Steel oi i ic,__°ij 10. 505-8 Act Assy. Brass 0 '44%•;.... .., \ F s71 J 0 © 4111 ,/ 11. BodyEnd BronzeASTM B 584 AlloyC84400 '%/\R. y-�4- y�y�ly/di�• iw 12. MountingScrew Steel �-Illi `"�'�'� o 11ml II1f1 13. Lock Washer Steel 0 111111110� IN cl o 14. Handle Pin Brass -�;;� - 15. Hand Wheel Steel/plastisol coated(1174'-21/i) -.B. Brass Tee Handle(1") 16. Indicator Flag Painted Steel 6 4!) 17. Body Gasket Elastomer 18. Lead Screw 0-Ring Nitrile _ ``p1; 19. Thrust Washer Anti-friction Polymer I,[_F LIOMM�1 II1 20. Cover Gasket Neoprene r��Z�o\�rT':�0"711 21. Flag Seal 0-Ring Nitrile E11 22. Tamper-Proof Screw Stainless Steel 23. Pipe Plug(-4 units) Stainless Steel(Not shown) m 00 Refer to page 41 for details for TS-2M Sw itchKit. 1 � 0 KT-505W DIMENSIONS-WEIGHTS-QUANTITIES Dimensions A B Weight Size Threaded Grooved Threaded Grooved C D E F G Cvt Threaded Grooved Box Master In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. Value Lbs. Kg. Lbs. Kg.Qty.Ctn.Qty. 1 25 3.33 85 - - 1.66 42 - - 2.11 54 3.81 97 2.31 59 6.14 156 1.75 44 57 6.1 2.77 - - 1 10 1Y4 32 4.18 106 - - 2.09 53 - - 2.46 62 4.21 107 2.72 69 6.33 161 3.50 89 103 7.1 3.23 - - 1 8 11/2 40 4.70 119 - - 2.35 60 - - 2.95 74 4.46 113 2.97 75 6.33 161 3.50 89 143 8.1 3.68 - - 1 4 2 50 5.15 131 6.71 170 2.57 65 3.36 85 3.69 94 4.67 119 3.18 81 6.33 161 3.50 89 245 10.7 4.86 9.7 4.40 1 4 2Y2 65 5.65 144 7.28 185 2.92 74 3.64 93 3.75 95 4.67 119 3.18 81 6.33 161 3.50 89 183 13.0 5.91 12.6 5.73 1 4 t Note:Cv is defined as the flow in GPM that a valve w ill carryw itha pressure drop of 1.0 psi w henthe media is w aterat 60°F. 4UL APPROVED NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 6 TECH SERVICES PH:1.888.446.4226•FAX:1.888.336.4226•INTERNATIONALOFFICE PH:+1.574.295.3327•FAX:+1.574.295.3455 www.nibco.com WILKJãPJmS a panPRESSURE GAUGES SPECIFICATION SUBMITTAL SHEET 60,0 00� 90 Qy tt �_ Model HGI-25 Model 92-25 & 92-25A Hose Bibb Pressure Gauge with Pressure Gauge Maximum pressure indicator Application: Application: Designedformeasuring watersystempressurewithina build- Designed for accuratelymeasuring system pressure down- ing. The 3/4"hose adapter allows for direct connection toa stream of a Pressure Reducing Valve.The Pressure gauge hose bibb or water heater drain valve.The indicator needle can be threaded directlyto all WI LKI NSPressure Reducing identifies the highest pressure reached within the system. Valves supplied with tapped or plugged option. For water Ideal for registering maximum system pressurecaused by service only. thermalexpansion or pressure spikes.The maximum pres- sure indicator needle can be reset by turning the external knob counter clockwise.For water service only. • I dentifywaterservicepressure to determine if a FEATURES pressure regulatoris needed. • Troubleshoolpressure problems. Sizes: ❑ 1/8" NPT(Model 92-25A) • I dentifythermalexpansion problems. ❑ 1/4" NPT(Model 92-25) FEATURES Dial size: 2" range:0-100 psi; minimum 2 psi graduation Sizes: ❑ 3/4" Hose Connection Dial size: 2" NOTE:A Pressure Regulatorshould be installed when sup- Range: 0-200 psi; minimum 2 psi graduation ply pressureexceeds 60psi. 3/4"hose adaptor Knurledfor easy gripping Sold in convenientpegboardpackaging �-p HOSE BIBB •F " • HOSE BIBB 121 HOSE BIBB 4/16111111.1 114111111111 PRESSURE PRESSURE GAUGE MODEL BR4 MODEL BR4 — REGULATOR mom f REGULATOR 1'101 IiI "41;ND 1I® PRESSURE GAUGE SHUT-OFF ' SHUT-OFF ' WATER VALVE I WATER VALVE—\,,m METER �IF METERIla y I 11111% DIRECTION OF FLOW I=D DIRECTION OF FLOW TYPICALINSTALLATION(MODEL HGI-25) TYPICALINSTALLATION(MODEL 92-25&92-25A) DOCUMENT#: REVISION: MIS-GAUGE 10/02 WILKINS OPERATION OF ZURN INDUSTRIES,1747 Commerce Way,Paso Robles,CA 93446 Phone:805/238-7100Fax:805/238-5766 IN CANADA:ZURN INDUSTRIES LIMITED,3544 Nashua Dr.,Mississauga,Ontario L4V 1L2 Phone:905/405-8272Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com WILKINSModel 800C Swing Away Ball Valves a ZURN.company For Li•uid or Gas Installations SPECIFICATION SUBMITTAL SHEET N, APPLICATION ' IlkDesigned for installation on liquid or medical gas lines as a means of positive shut-off.The "swing away" design al- lows for repair and maintenance without removing the 1 device from the line. ,,,,d MATERIALS FEATURES Main valve body Forged brass('/2"-1") Sizes: ❑ '/2" ❑ 3/4" ❑ 1" ❑ 1'/2" Cast bronzeASTM B 584(11/2"-3") ❑ 2" ❑ 2 '/2" ❑ 3" Ball Brass ASTM B 16, chrome plated Seat& packing Teflon Maximum pressure 400 PSI WOG 0-rings Buna Nitrile, NSF Listed Copper connections(FC) ANSI B16.22 SPECIFICATION The three piece swing away ball valve shall consist of a OPTIONS copper alloy body,two tailpieces, a hard-chromed copper alloy ball,two Teflon seats, a stem and coated handle. The ❑ - with female copper inlet x outlet stem shall be blow-out proof and the ball &seats replace- CI CL - with copper"L"tube extensions able in-line without the use of special tools.Tailpieces shall be designed to accept sweated copper tube or provided ACCESSORIES with copper tailpiece extensions. The three piece swing away ball valve shall be a WILKINS Model 800C. ❑ Repair kit;o-rings, stem and seats ❑ Bracket for locking ball valve handle in open position I C = (Model BVLCK) ❑ Bracket and padlock(Model BVLCKP) 7 liii'0! 1 DIMENSIONS &WEIGHTS(do not include pkg.) A DIMENSIONS (approximate) 1 SIZE A B C WEIGHTS in. m m in. m m in. mm in. mm lbs. kg. 1 /2 15 2 1/8 54 1 5/8 41 3 7/8 98 1 0.5 3/4 20 2 3/4 70 1 7/8 48 3 7/8 98 1 0.5 1 25 31/2 89 2 51 41/2 ' 114 2 1.0 1 1/2 40 4 7/8 124 2 7/8 73 6 152 7 3.0 j 2 50 51/2 140 31/8 79 6 152 9 4.0 2 1/2 65 6 3/8 162 3 5/8 92 6 152 17 8.0 3 80 6 3/4 172 4 3/8 111 12 305 22 10.0 DOCUMENT#: REVISION: BV-800C 5/05 WILKINS OPERATION OF ZURN INDUSTRIES,1747 Comm erceWay,Paso Robles,CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA:ZURN INDUSTRIES LIMITED,3544 Nashua Dr.,Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com NIBCO www.nibco.corn Alli AD_ `O F THE ILO yn/ Revision 5/14/02 Copper Water Tube continued DIMENSIONAL DATA-COPPER WATER TUBE-TYPE"M" TYPE"M" Hard Drawn Only: 20-ft.(6.1m)Straight Lengths Usage: For general purpose plumbing,heating and drainage installations. Tolerances Hard Drawn (Hard Drawn Only) Outside Tubing OD Nominal Wall Weight Bursting Safe Working Nominal Diameter Thickness Per Foot Pressure" Pressures Water Tube Min. Max. Size(In Inches) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Lb (kg) psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) N/A N/A N/A N/A N/A N/A N/A N/A 3/8 0.5W (12.70) 0.497 (12.62) 0.501 (12.73) 0.025 (0.64) 0.145 (0.07) N/A N/A 855 (59) 1/2 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.028 (0.71) 0.204 (0.09) 6135 (423) 741 (51) 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) N/A N/A N/A N/A N/A N/A N/A N/A 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.032 (0.81) 0.328 (015) 4717 (325) 611 (42) 1 1125 (28.58) 1.122 (28.50) 1127 (28.63) 0.035 (0.69) 0.465 (0.21) 3865 (266) 506 (35) 11/4 1.375 (34.93) 1.372 (34.85) 1,377 (34.98) 0.042 (1.07) 0.682 (0.31) 3875 (267) 507 (35) 11/2 1.625 (41.28) 1.621 (4117) 1.627 (41.33) 0.049 (1.24) 0.940 (0.43) 3550 (245) 497 (34) 2 2125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.058 (1.47) 1.460 (0.66) 2935 (202) 448 (31) 21/2 2,625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.065 (1.65) 2.030 (0.92) 2800 (193) 411 (28) 3 3125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.072 (1,83) 2.620 (1.22) 2665 (184) 380 (26) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (9213) 0.083 (2.11) 3.580 (1.62) N/A N/A 378 (26) 4 4125 (104.78) 4.121 (104.67) 4127 (104.83) 0.095 (2.41) 4.660 (2.11) 2215 (153) 377 (26) 5 5125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.109 (2.77) 6.660 (3.02) 2490 (172) 349 (24) 6 6125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.122 (310) 8.920 (4.05) 2000 (138) 328 (23) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.170 (4.32) 16.500 (7.48) 2285 (158) 344 (24) 10 10,125 (25718) 10.119 (257.02) 10.127 (257.23) 0.212 (5.38) 25.600 (11.61) N/A N/A 344 (24) 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.254 (6.45) 36.700 (16.65) N/A N/A 345 (24) Note:Information and data contained in these charts,as taken from ASTM Specifications 8 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanical joints "Based on actual laboratory test data provided by Copper Development Association,Inc. `Based upon 150°F(65 6°C)with an allowable stress of 9500 psi(668 kPa). U.S.customary units in this document are the standard;the metric units are provided for reference only.The values stated in each system are not exact equivalents. It] NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH:1.800.234.0227 TECH SERVICES PH:1.888.446.4226•FAX 1.800.234,0557•INTERNATIONAL SERVICE PH:+1,574.295.3221 •FAX:+1.574,2953455