HomeMy WebLinkAboutF18-0052_Approved Documents_1534341098.pdf 2/8/2017 69 Adjustable Swivel Ring-Pipe Hangers&Hardware I Anvil Home I News I Careers I Contact Us I Submittal Manager YNTER AT IN AL Building Connections That Last ABOUT US BRANDS INDUSTRIES PRODUCTS ENGINEERING PROJECT LITERATURE& PRODUCT SEARCH RESOURCES ACCELERATION PRICE SHEETS PRODUCTS Login I Create a Submittal Account Grooved Pipe Hangers&Hardware>Pipe Rings Gruvlok® FIG 69 Gruvlok®FireProtection 69 Adjustable Swivel Ring SPF Grooved Engineered Pipe Supports Size Range: 1/2"through 8" - • Spring Hangers Material:Carbon steel Constant Supports - . Finish: Strap is Pre-Galvanized Zinc Material.Nut is Zinc Plated. Vibration Control&Sway Brace Service:Recommended for suspension of non-insulated stationary Sway Strut Assembly pipe line. Snubbers Maximum Temperature: 650° F • Special Design Products Approvals: Complies with Federal Specification A-A-1192A(Type 10), Pipe Hangers&Hardware WW-H-171-E (Type 10), ANSI/MSS SP-69 and MSS SP-58(Type 10). Copper Tubing Hangers UL Listed and FM Approved (Sizes 3/4"-8"). h. Stainless Steel Hangers Features: Pipe Rings . Threads are countersunk so that they cannot become burred or damaged. Clevis •. Knurled swivel nut provides vertical adjustment after piping is in , Steel Pipe Clamps place. Socket Clamps . Captured swivel nut in the 1/2"through 6"sizes.The capture is • permanent in the bottom portion of the band, allowing the hanger Beam Clamps to be opened during installation if desired, but not allowing the nut Structural Attachments to fall completely out. Brackets Ordering:Specify size,figure number and name. Ceiling Plates&Ceiling Flanges Note:The acceptability of galvanized coatings at temperatures above 450°F is at the Concrete Inserts&Attachments discretion of the end user. Hanger Rods&Accessories Metric nut available upon request.Non-captured nut also available upon request. Rod Attachments Bolts,Nuts,Pins&U-Bolts Straps Get More Information Pipe Supports Trapeze Pipe Shields&Saddles Pipe Rolls Product Data Sheets Listings,Approvals&Certifications Pipe Guide&Slides I Figure 69 Submittal Info Sheet Seismic Sway Bracing Andrn Part <>Info Sheet Approved roved ® ULus Listed TriFlexLoop For Fire ProtectionAPPROVED InThe Pipe Brace Clamps Loading and Dimensions Structural Attachments Restraints Technical&CAD Data Sway Brace Attachment CAD Drawing for 69 Adjustable Swivel Ring TriFlexLoop Pipe Fittings Anvil Pipe Fittings SPF Pipe Fittings Strut&Strut Fittings Channels Channel Nuts Channel Hardware Beam Clamps Flat Plates http://www.anvi l i ntl.com/products/pi pe-hangers-and-hardware/pipe-ri ngs/69-fi gure-adj ustabl e-swivel-ring 1/2 2/8/2017 69 Adjustable Swivel Ring-Pipe Hangers&Hardware I Anvil Splice Clevises "U"Supports "Z"Supports Angle Fittings&Connectors Wing Fittings Brackets Post Bases Trolleys&Accessories Pipe&Conduit Supports Concrete Inserts End Caps Miscellaneous Fittings Anvil Rooftop Products HBM-Support HBM-HPC Series HBM-CE5 Extension Series HBS-Support HBS-CB Bridge Series HBS-CE Extension Series HBS-Roller Series HBS-CES Series HBS-DSFW Fixed Width Duct Support HBS-DSAW Adjustable Duct Support HBS-PH Light Duty Pipe Hanger Support HBS-PH Medium Duty Pipe Hanger Support HBS-PH Heavy Duty Pipe Hanger Support Coated Products Coated Products Valves Mueller UL/FM Valves Hydronic Balancing Valves Grooved Valves Valve Accessories OUR BRANDS -? ?ra+w 111=1 T /Sf11�.p1/IL EPs R rte*` nnnni srxrr .o ... North Alabama Pipe About Us Brands Products Industries About Anvil Anvil Grooved Mechanical&Industrial Building Connections Gruvlok Engineered Pipe Supports Fire Protection History SPF Pipe Hangers&Hardware Energy Plant Locations Beck Seismic Sway Bracing Customer Service Centers Anvil-Strut Pipe Fittings Tradeshows J.B.Smith Strut&Strut Fittings Published Articles Merit Coated Products Catawissa Mueller UL/FM Valves Anvil EPS Mueller NAP Anvil International is a subsidiary of Mueller Water Products,Inc. ©2017 Anvil International Legal and Privacy Statement Transparency in Supply Chains Act Disclosure Sitemap http://www.anvi I i ntl.com/products/pi pe-hangers-and-hardware/pipe-ri ngs/69-fi gure-adj ustabl e-swivel-ring 2/2 HANGER RODS 0.4wR4 Fig. 146 Continuous Threaded Rod Size Range:'/4"through 1'/2"Stocked in six,ten,and twelve foot lengths.Other even foot lengths can be furnished to order. Material:Carbonsteel or Stainless Steel Gr 304 Threads:National Coarse(USS),rod threaded complete length. " ""'��t'Iflflt�ll(II?'.,c++rt��i�+��a�ir++ i + Finish:❑Plain or Galvanized. Maximum Temperature:650°F. Ordering:Specify rod diameter and length,figure number, name and finish. Note:The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. FIG. 146: L CADS(LBS).WEIGHTS(LBS).DIMENSIONS(IN) Rod Size Threads Max Load Weight A per Inch 650° F per Ft. Length 1/4 20 240 0.12 3/s 16 730 0.30 IMISSOMOSIS�����������NISIONSMISSISMOSNI I '/2 13 1,350 0.53 5/s 11 2,160 0.84 A 3/4 10 3,230 1.20 7/4 9 4,480 1.70 1 8 5,900 2.30 11/4 7 9,500 3.60 11/2 6 13,800 5.10 Note:Other rod sizes av ailableupon request.Class 2 fit is av ailableupon request. PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engi neer: Remarks: Submittal Date: Notes 1: Notes 2: PH-11.11 diM67 M:1 PIPP: _ _ _ Fire Protection by Computer Design MERIDAN INTERMOUNTAIN P 0 BOX 3940 #1 AVON, CO 970-748-8888 Job Name : AXEL'S RETAIL AREA 1 Building : Location : System : Contract : Data File : AREA 1 7-10-2018.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MERIDAN INTERMOUNTAIN Page 1 AXEL'S RETAIL AREA 1 Date 7-10-2018 HYDRAULIC CALCULATIONS for Project name: AXEL'S RETAIL AREA 1 Location: Drawing no: Date: 7-10-2018 Design Remote area number: Remote area location: Occupancy classification: Density: .2 - Gpm/SqFt Area of application: - SqFt Coverage per sprinkler: 95.62 - SqFt Type of sprinklers calculated: No.of sprinklers calculated: 17 In-rack demand: - GPM Hose streams: 0 - GPM Total water required(including hose streams): 407.731 - GPM @ 111.106 - Psi Type of system: Volume of dry or preaction system: - Gal Water supply information Date: Location: Source: Name of contractor: MERIDAN INTERMOUNTAIN Address: P 0 BOX 3940 /#1 /AVON, CO Phone number: 970-748-8888 Name of designer: Authority having jurisdiction: Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C MERIDAN INTERMOUNTAIN Page 2 AXEL'S RETAIL AREA 1 Date 7-10-2018 City Water Supply: Demand: Cl - Static Pressure : 135 D1 - Elevation : 15.592 C2 - Residual Pressure: 49.46 D2 - System Flow : 407.731 C2 - Residual Flow : 1180.06 D2 - System Pressure : 111.106 Hose ( Demand ) D3 - System Demand : 407.731 Safety Margin : 11.917 150 140 s Cl 130 P 120 R110 E 100 S90 • S 80 U 70 R 60 C2 E 50 . 40 30 20 10 D1 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N " 1.85 ) Computer Program sby Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram MERIDAN INTERMOUNTAIN Page 3 AXEL'S RETAIL AREA 1 Date 7-10-2018 21 H1 F L1 I 21 22.? H2 - L2 20.4 H3 - L3 T I 20.4 23.P H4 - L4 19.1 H5 - L5 T I 19.1 20.? H6 -L6 T I 39.4 22.g H7 F L7 23.6 H8 -L8 T I 23.6 24.? H9 -L9 I 48.2 26 i H104-L10 22.2 H11F L11 25 H124-L12 I 25 25.? H134- L13 25.2 H144- L14 T I 25.2 26 i H154-L15 29.9 H164- L16 T I 29.9 311 H174- L17 21 L1 L2 M1 43.6 19.1 61.7 L5 -L6 - L7 - M2 39.4 20.4 L3 -L4 - M3 1' 43.5 I 43.5 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram MERIDAN INTERMOUNTAIN Page 4 AXEL'S RETAIL AREA 1 Date 7-10-2018 22.? L11<- M3 23.6 74.2 L8 - L9 - L10- M5 48.2 221.5 25 L12-L13- M4 50.$ I 221.5 25.2 I L144- L15<- M5 51.$ I 34q.9 29.9 I L164- L17_ M6 60.9 43.6 171, 346.9 407.7 407.7 407.7 407.7 M1 - M2- M3-M4_ M5_ M6_ M7_ MR1F TR44_ TR34_ TR2_ TR14_ TOR- BOR- TEST 105.3 221.5 407.7 407.7 407.7 407.7 407.7 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary MERIDAN INTERMOUNTAIN Page 5 AXEL'S RETAIL AREA 1 Date 7-10-2018 Fitting Legend Abbrev. Name /2 3/4 1 1'/4 1% 2 2'/z 3 3'% 4 5 6 8 10 12 14 16 18 20 24 A Alarm Rel El &E3 7.7 21.5 17 27 29 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zib Wilkins 350A Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diam eters of Sched 40 pipe and CFactors of 120 except as noted with*. The fittings marked with a *show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a *will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Program sby Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure/ Flow Summary- STANDARD MERIDAN INTERMOUNTAIN Page 6 AXEL'S RETAIL AREA 1 Date 7-10-2018 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. H1 30.0 5.6 14.12 na 21.04 0.2 95.62 11.66 H2 30.0 5.6 16.26 na 22.58 0.2 95.62 11.66 H3 30.0 5.6 13.31 na 20.43 0.2 95.62 11.66 H4 30.0 5.6 16.97 na 23.07 0.2 95.62 11.66 H5 30.0 5.6 11.66 na 19.12 0.2 95.62 11.66 H6 30.0 5.6 13.15 na 20.31 0.2 95.62 11.66 H7 30.0 5.6 15.76 na 22.23 0.2 95.62 11.66 H8 30.0 5.6 17.73 na 23.58 0.2 95.62 11.66 H9 30.0 5.6 19.3 na 24.6 0.2 95.62 11.66 H10 30.0 5.6 21.59 na 26.02 0.2 95.62 11.66 H11 30.0 5.6 15.72 na 22.2 0.2 95.62 11.66 H12 30.0 5.6 19.91 na 24.99 0.2 95.62 11.66 H13 30.0 5.6 20.77 na 25.52 0.2 95.62 11.66 H14 30.0 5.6 20.17 na 25.15 0.2 95.62 11.66 H15 30.0 5.6 21.6 na 26.02 0.2 95.62 11.66 H16 30.0 5.6 28.47 na 29.88 0.2 95.62 11.66 H17 30.0 5.6 30.59 na 30.97 0.2 95.62 11.66 L1 31.0 15.26 na L2 31.0 17.62 na L5 31.0 12.55 na L6 31.0 14.19 na L7 31.0 17.06 na L3 31.0 14.37 na L4 31.0 18.4 na L11 31.0 17.02 na L8 31.0 19.24 na L9 31.0 20.96 na L10 31.0 23.49 na L12 31.0 21.63 na L13 31.0 22.58 na L14 31.0 21.93 na L15 31.0 23.49 na L16 31.0 31.05 na L17 31.0 33.37 na M1 31.0 21.1 na M2 31.0 21.12 na M3 31.0 21.22 na M4 31.0 23.98 na M5 31.0 27.44 na M6 31.0 39.61 na M7 31.0 45.38 na MR1 31.0 46.3 na TR4 31.0 54.23 na TR3 31.0 63.1 na TR2 31.0 80.21 na TR1 31.0 81.26 na TOR 11.0 94.97 na BOR 3.0 103.11 na TEST -6.0 111.11 na The maximum velocity is 17.7 and it occurs in the pipe between nodes TR4 and TR3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 MERIDAN INTERMOUNTAIN Page 7 AXEL'S RETAIL AREA 1 Date 7-10-2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H1 21.04 1.049 1T 5.0 6.000 14.120 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L1 21.04 0.1429 0.0 11.000 1.572 Vel = 7.81 0.0 21.04 15.259 K Factor= 5.39 H2 22.58 1.049 1T 5.0 6.000 16.260 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L2 22.58 0.1628 0.0 11.000 1.791 Vel = 8.38 0.0 22.58 17.618 K Factor= 5.38 H3 20.43 1.049 1T 5.0 6.000 13.314 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L3 20.43 0.1354 0.0 11.000 1.489 Vel = 7.58 0.0 20.43 14.370 K Factor= 5.39 H4 23.07 1.049 1T 5.0 6.000 16.972 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L4 23.07 0.1695 0.0 11.000 1.864 Vel = 8.56 0.0 23.07 18.403 K Factor= 5.38 H5 19.12 1.049 1T 5.0 6.000 11.662 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L5 19.12 0.1198 0.0 11.000 1.318 Vel = 7.10 0.0 19.12 12.547 K Factor= 5.40 H6 20.31 1.049 1T 5.0 6.000 13.154 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L6 20.31 0.1339 0.0 11.000 1.473 Vel = 7.54 0.0 20.31 14.194 K Factor= 5.39 H7 22.23 1.049 1T 5.0 6.000 15.755 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L7 22.23 0.1582 0.0 11.000 1.740 Vel = 8.25 0.0 22.23 17.062 K Factor= 5.38 H8 23.58 1.049 1T 5.0 6.000 17.733 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L8 23.58 0.1765 0.0 11.000 1.941 Vel = 8.75 0.0 23.58 19.241 K Factor= 5.38 H9 24.60 1.049 1T 5.0 6.000 19.296 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L9 24.6 0.1908 0.0 11.000 2.099 Vel = 9.13 0.0 24.60 20.962 K Factor= 5.37 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MERIDAN INTERMOUNTAIN Page 8 AXEL'S RETAIL AREA 1 Date 7-10-2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H10 26.02 1.049 1T 5.0 6.000 21.590 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L10 26.02 0.2117 0.0 11.000 2.329 Vel = 9.66 0.0 26.02 23.486 K Factor= 5.37 H11 22.20 1.049 1T 5.0 6.000 15.719 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L11 22.2 0.1578 0.0 11.000 1.736 Vel = 8.24 0.0 22.20 17.022 K Factor= 5.38 H12 24.99 1.049 1T 5.0 6.000 19.907 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L12 24.99 0.1964 0.0 11.000 2.160 Vel = 9.28 0.0 24.99 21.634 K Factor= 5.37 H13 25.52 1.049 1T 5.0 6.000 20.767 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L13 25.52 0.2043 0.0 11.000 2.247 Vel = 9.47 0.0 25.52 22.581 K Factor= 5.37 H14 25.15 1.049 1T 5.0 6.000 20.175 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L14 25.15 0.1988 0.0 11.000 2.187 Vel = 9.34 0.0 25.15 21.929 K Factor= 5.37 H15 26.02 1.049 1T 5.0 6.000 21.597 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L15 26.02 0.2118 0.0 11.000 2.330 Vel = 9.66 0.0 26.02 23.494 K Factor= 5.37 H16 29.88 1.049 1T 5.0 6.000 28.473 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L16 29.88 0.2735 0.0 11.000 3.008 Vel = 11.09 0.0 29.88 31.048 K Factor= 5.36 H17 30.97 1.049 1T 5.0 6.000 30.591 K Factor= 5.60 to 120.0 0.0 5.000 -0.433 L17 30.97 0.2923 0.0 11.000 3.215 Vel = 11.50 0.0 30.97 33.373 K Factor= 5.36 L1 21.04 1.049 4E 8.0 8.500 15.259 to 120.0 0.0 8.000 0.0 L2 21.04 0.1430 0.0 16.500 2.359 Vel = 7.81 L2 22.58 1.38 4E 12.0 6.040 17.618 to 120.0 1T 6.0 18.000 0.0 M1 43.62 0.1448 0.0 24.040 3.482 Vel = 9.36 Corn puter Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MERIDAN INTERMOUNTAIN Page 9 AXEL'S RETAIL AREA 1 Date 7-10-2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 43.62 21.100 K Factor= 9.50 L5 19.12 1.049 4E 8.0 5.750 12.547 to 120.0 0.0 8.000 0.0 L6 19.12 0.1198 0.0 13.750 1.647 Vel = 7.10 L6 20.31 1.38 4E 12.0 5.870 14.194 to 120.0 1T 6.0 18.000 0.0 L7 39.43 0.1202 0.0 23.870 2.868 Vel = 8.46 L7 22.23 1.61 4E 16.0 7.290 17.062 to 120.0 1T 8.0 24.000 0.0 M2 61.66 0.1297 0.0 31.290 4.059 Vel = 9.72 0.0 61.66 21.121 K Factor= 13.42 L3 20.43 1.049 4E 8.0 16.790 14.370 to 120.0 1T 5.0 13.000 0.0 L4 20.43 0.1354 0.0 29.790 4.033 Vel = 7.58 L4 23.07 1.38 4E 12.0 1.580 18.403 to 120.0 1T 6.0 18.000 0.0 M3 43.5 0.1441 0.0 19.580 2.822 Vel = 9.33 0.0 43.50 21.225 K Factor= 9.44 L11 22.20 1.049 2E 4.0 22.620 17.022 to 120.0 0.0 4.000 0.0 M3 22.2 0.1579 0.0 26.620 4.203 Vel = 8.24 0.0 22.20 21.225 K Factor= 4.82 L8 23.58 1.049 2E 4.0 5.750 19.241 to 120.0 0.0 4.000 0.0 L9 23.58 0.1765 0.0 9.750 1.721 Vel = 8.75 L9 24.60 1.38 2E 6.0 8.500 20.962 to 120.0 0.0 6.000 0.0 L10 48.18 0.1741 0.0 14.500 2.524 Vel = 10.33 L10 26.02 1.61 2E 8.0 5.620 23.486 to 120.0 1T 8.0 16.000 0.0 M5 74.2 0.1827 0.0 21.620 3.950 Vel = 11.69 0.0 74.20 27.436 K Factor= 14.17 L12 24.99 1.38 2E 6.0 12.330 21.634 to 120.0 0.0 6.000 0.0 L13 24.99 0.0517 0.0 18.330 0.947 Vel = 5.36 L13 25.52 2.067 4E 20.0 22.540 22.581 to 120.0 1T 10.0 30.000 0.0 M4 50.51 0.0266 0.0 52.540 1.395 Vel = 4.83 0.0 50.51 23.976 K Factor= 10.32 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MERIDAN INTERMOUNTAIN Page 10 AXEL'S RETAIL AREA 1 Date 7-10-2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn L14 25.15 1.049 0.0 7.870 21.929 to 120.0 0.0 0.0 0.0 L15 25.15 0.1989 0.0 7.870 1.565 Vel = 9.34 L15 26.03 1.38 4E 12.0 2.250 23.494 to 120.0 1T 6.0 18.000 0.0 M5 51.18 0.1947 0.0 20.250 3.942 Vel = 10.98 0.0 51.18 27.436 K Factor= 9.77 L16 29.88 1.049 0.0 8.500 31.048 to 120.0 0.0 0.0 0.0 L17 29.88 0.2735 0.0 8.500 2.325 Vel = 11.09 L17 30.97 1.38 4E 12.0 5.250 33.373 to 120.0 1T 6.0 18.000 0.0 M6 60.85 0.2682 0.0 23.250 6.235 Vel = 13.05 0.0 60.85 39.608 K Factor= 9.67 M1 43.62 2.635 0.0 3.250 21.100 to 120.0 0.0 0.0 0.0 M2 43.62 0.0065 0.0 3.250 0.021 Vel = 2.57 M2 61.67 2.635 0.0 3.290 21.121 to 120.0 0.0 0.0 0.0 M3 105.29 0.0316 0.0 3.290 0.104 Vel = 6.19 M3 65.70 2.635 2E 16.474 2.460 21.225 to 120.0 1T 16.474 32.948 0.0 M4 170.99 0.0777 0.0 35.408 2.751 Vel = 10.06 M4 50.51 2.635 6F 24.711 2.870 23.976 to 120.0 0.0 24.711 0.0 M5 221.5 0.1254 0.0 27.581 3.460 Vel = 13.03 M5 125.38 3.26 8E 75.261 3.750 27.436 to 120.0 2T 40.319 115.580 0.0 M6 346.88 0.1020 0.0 119.330 12.172 Vel = 13.33 M6 60.85 3.26 4E 37.631 4.330 39.608 to 120.0 0.0 37.631 0.0 M7 407.73 0.1376 0.0 41.961 5.772 Vel = 15.67 M7 0.0 3.26 0.0 6.700 45.380 to 120.0 0.0 0.0 0.0 MR1 407.73 0.1375 0.0 6.700 0.921 Vel = 15.67 MR1 0.0 3.26 4E 37.631 20.000 46.301 to 120.0 0.0 37.631 0.0 TR4 407.73 0.1375 0.0 57.631 7.927 Vel = 15.67 TR4 0.0 3.068 4E 28.0 20.000 54.228 to 120.0 0.0 28.000 0.0 TR3 407.73 0.1849 0.0 48.000 8.874 Vel = 17.70 TR3 0.0 3.26 8E 75.261 33.000 63.102 to 120.0 4F 16.127 91.388 0.0 TR2 407.73 0.1376 0.0 124.388 17.110 Vel = 15.67 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MERIDAN INTERMOUNTAIN Page 11 AXEL'S RETAIL AREA 1 Date 7-10-2018 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn TR2 0.0 4.26 0.0 28.000 80.212 to 120.0 0.0 0.0 0.0 TR1 407.73 0.0374 0.0 28.000 1.047 Vel = 9.18 TR1 0.0 4.26 0.0 135.000 81.259 to 120.0 0.0 0.0 8.662 TOR 407.73 0.0374 0.0 135.000 5.046 Vel = 9.18 TOR 0.0 4.26 1A 22.384 20.000 94.967 to 120.0 1G 2.633 25.017 6.465 * * Fixed Loss = 3 BOR 407.73 0.0374 1Fsp 0.0 45.017 1.682 Vel = 9.18 BOR 0.0 6.16 3E 45.302 100.000 103.114 to 120.0 1G 3.236 80.897 6.869 * * Fixed Loss = 2.972 TEST 407.73 0.0062 1T 32.359 180.897 1.123 Vel = 4.39 1Zib 0.0 0.0 407.73 111.106 K Factor= 38.68 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 2/8/2017 Fire Protection Pipe Fittings and Piping Connections I Anvil Intl Home I News I Careers I Contact Us I Submittal Manager quir..:;;AS,RIVIE Building Connections That Last ,N' INT ERM ATI ONAL ABOUT US BRANDS INDUSTRIES PRODUCTS ENGINEERING PROJECT LITERATURE& PRODUCT SEARCH RESOURCES ACCELERATION PRI CESHEETS PRODUCTS FOR FIREF PROTECTION f r . Show All ] II I ; Grooved Gruvlok® f - •IA • •.' ' Gruvlok®Fire Protection . 1 SPF Grooved I 'u K.,r Pipe Hangers&Hardware 11.' 0 I4 /t Pipe Rings t. Clevis Steel Pipe Clamps Beam Clamps Brackets Fire Protection Select Language • Seismic Sway Bracing And Anvil's unmatched range of domestic and Powered by Google Translate TriFlexLoop For Fire Protection globally sourced products for fire y Pipe Brace Clamps protection piping systems provide • ' • Links versatile and dependable performance Structural Attachments for a wide range of applications.Anvil Industries> products pprove are Ur availableted and wide M- t1101 1:11T Mechanical&Industrial> Restraints approved,and are available in a wide range of styles and functionality.Anvil Fire Protection> Sway Brace Attachment 9 Y Energy> combines the latest technology and most Pipe Fittings current fire protection ratings with the Anvil Pipe Fittings trusted history and manufacturing experience that have made Anvil the go-to Resources source for fire protection piping products.And that means better performance Fire Protection Brochure> SPF Pipe Fittings and better service for you and your business. NAP Brochure> Strut&Strut Fittings Channels Learn more about Anvil's Fire Protection Products Channel Nuts Seismic Bracing Solutions—Anvil offers seismic bracing solutions for the fire protection industry that deliver unrivaled quality versatility.Our seismic Channel Hardware fire protection design tool simplifies product selection and let's you easily Beam Clamps calculate whether or not a seismic fire protection system meets its seismic load requirements. Flat Plates Gruvlok—Gruvlok®Valves are compact,cost effective and designed for Splice Clevises use in grooved-end pipe fire protection systems and related equipment. "U"Supports They are UL/ULC listed.GruvlokCouplings and fittings are designed to provide quick,secure and reliable solutions forjoining pipe-to-pipe. "Z"Supports SPFTM'—SPFT"Grooved Couplings Fittings provide a rigid or flexible pipe Angle Fittings&Connectors connection for fire protection systems with dependable seals over a range of Wing Fittings internal pressure situations.SPFTM also offers Short Pattern Products through 8"to meet all of your fire protection needs. Brackets Steel Pipe Nipples and Steel Pipe Couplings—Anvil offers a huge variety Post Bases of Steel Pipe Nipples and Steel Pipe Couplings for the fire protection Trolleys&Accessories industry. Pipe&Conduit Supports Pipe H angers—The Anvil®brand of pipe hangers brings 150 years of experience to our fire-rated product line. Concrete Inserts Cast I ronand Malleable I ronThreaded Fittings—Anvil offers the most End Caps complete line of Cast Iron and Malleable Iron Threaded Fittings in the Miscellaneous Fittings industry.Our versatile range of fittings provides highly dependable, fire-rated service. Valves Anvil Fire Protection TriFlex Loop—The Anvil Fire Protection Tri-Flex Loop Mueller UL/FM Valves is the safest and most reliable means of absorbing movement resulting from Hydronic Balancing Valves thermal changes and random seismic shifts in a fire protection system. Grooved Valves Mueller®–Mueller®Valves are available in a variety of styles for fire protection applications including Resilient Wedge Gate Valves,O.S.&Y. Valve Accessories Resilient Wedge Stem Gate Valves,and Swing-Type Check Valves. Mueller®Valves are ideal for flanged fire pump applications and other system control valve needs. http://www.anvilintl.com/industries/fire-protection.aspx 1/2 VSR q, POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL,CUL and CSFM Listed,FM Approved,LPCBApproved,For CE Marked(EN12259-5)/VdS Approved model use VSR-EU ServicePressure: 450 PSI(31 BAR)-UL FlowSensitivityRangeforSignal: 4-10 GPM(15-38 LPM)-UL MaximumSurge: 18 FPS(5.5 m/s) Contact Ratings: TwosetsofSPDT(FormC) 10.0Ampsat 125/250VAC 2.0 Amp sat30VDC Resistive 10 mAmpsmin.at 24VDC ConduitEntrances: Twoknockoutsprovidedforl/2"conduit. Individual switchcompartments suitable f ordissimilarvoltages. Environ mentaiSpecifications: • NEMA4/IP54 RatedEnclosure suitable forindooror outdooruse with f actoryinstalle c aske land die-casthousing whenusedwithappropriate conduitfitting. • Temperature Range: 40°F-120°F,(4.5°C-49°C)-UL • Non-corrosivesleevefactory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 Specifications subject to change without notice. One or two family dwelling NFPA-13D Ordering Information Residential occupancy up to four stories NFPA-13R Nominal Pipe Size Model Part Number National Fire Alarm Code NFPA-72 2" DN50 VSR-2 1144402 2 1/2" DN65 VSR-2 1/2 1144425 ! WARN IN ti • Installation must be performed by qualified personnel and in 3" DN80 VSR-3 1144403 accordance with all national and local code sand ordinances. 3 1/2" - VSR-3 1/2 1144435 • Shock hazard.Disconnect power source before servicing. Serious 4" DN 100 VSR-4 1144404 injury or de athcould result. • Risk of explosion.Not foruse in hazardous locations.Serious 5" VSR-5 1144405 injury or de athcould result. 6" DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 CAUTION Optional Cover Tamper Switch Kit,stock no.0090148 Waterflowswitchesthataremonitoringwetpipesprinkleisystemsshall Replaceable Components:Retard/Switch Assembly,stockno.1029030 not be used as the sole initiating device to discharge AFFF,deluge. or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges trapped air,or shortretard times. Important: This document contains important information on the installation and operation of the VSR waterflow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA72 to be maintained on site. General Information Enclosure The Model VSR is a vane type waterflowswitchf oruse on wet sprinkler The VSR switches and retard device are enclosed in a general purpose, systems.It is UL Listed for use on a steel pipe;schedules 5 through 40, die-cast housing. The cover is held in place with two tampe rresistant sizes 2"-6"and is UL Listed and FM Approved foruse on steel pipe; screws which require a special key for removal. A field installable schedules 10 through 40,sizes 2"thru 8"(50 mm thru 200 mm).LPC cover tamper switch is available as an option which may be used approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering to indicate unauthorized removal of the cover. See bulletin number Information chart. 5401103 for installation instructions of this switch. The VSR may also be used as a sectional waterflow detector on larg e systems.The VSR contains two sing lepole,double throw,snap action switches and an adjustable,instantly recycling pneumatic retard. The switches are actuatedwhena flow of 10 GPM(38 LPM)or more occurs downstream of the device. The flow condition must exist fora period of time necessary to overcome the selected retard period. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG.#5401146-REV M PAGE 1 OF 4 11/15 VSR P POTTER VANE TYPE WATERFLOW ® The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6"(15 cm)of a fitting which changes the direction of the waterfiow or within 24" (60 cm)of a valve or drain. NOTE:Do not leave cover offforan extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow spe eddrill(see Fig. 1). Cle an the inside pipe of all growth or other material for a distance e qualto the pipe diameter on e itherside of the hole.Roll the vane so that it may be inserted into the hole;do not bend or crease it.Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe.Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle.Failure to follow these instructions may prevent the device from operating and will void the warranty.Do not obstruct or otherwise prevent the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm.If an alarm is not desired,a qualified technician should disable the alarm system. Fig.1 RetardAdjustment DO NOTLEAVE COVER OFFFOR �� AN EXTENDED PERIOD OF TIME The de laycan be adjusted by rotating the retard adjustment knob from Sili ...4,4 0 to the max setting(60-90 seconds).The time delay shouldbe set at • ;, r- the minimum required to prevent false alarms rte, �� j_\ , . ���\101191/ TIGHTENNUTS :II,,., , ; ill, ����� ALTERNATELY CAUTION ,11 ' -----40-0,30-i-I I:/ Hole must be drilled perpendicular to the pipe and vertically centered. `,� �'" / Refer to the Compatible Pipe/Installation Requirements chartforsize. I Correct Incorrect Ik, MOUNTON PIPE SO ARROW ON SADDLE - \J POINTS R DIRECTION O �j V �10� OF WATERFLOW ............, 0411ips..._., ...mi.,. WIW ROLL PADDLE IN I 50mm I OPPOSITE DIRECTION ADAPTER �rADAPTER DIRECTION OF OF WATERFLOW \�\\` %//// WATERFLOW .41111141101.. 20mm t2mm MAX. \\ \ (Flowing water activates device in one direction only) DN50 ONLY J USE(2)5180162 ADAPTERS AS SHOWN ABOVE DWG. 1146-11 DWG#1146-1F Compatible Pipe/Installation Requirements Model Nominal Pipe Nominal Pipe Pipe Wall Thickness Hole Size U-BoltNuts Size O.D. Lightwall Schedule 10(UL) Schedule 40(UL) BS-1387(LPC) DN(VDS) Torque inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 - - - - 1.25+.125/- VSR-21/2 2.5 - 2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 - - - - 33.0+2.0 - .062 VSR-2 1/2 - DN65 3.000 76.1 - - - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 VSR-3 1/2 3.5 - 4.000 101.6 - - 0.120 3.05 0.226 5.74 - - - - 20 27 VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 - 2.00±.125 50.8+2.0 VSR-5 5 - 5.563 141.3 - - 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DN150 6.625 168.3 .115 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 - - 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 NOTE:For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG.#5401146-REV M PAGE2 OF 4 11/15 VSR VANE TYPE WATERFLOW 1, POTTER The Symbol of Protection ALARM SWITCH WITH RETARD Fig.2 Fig.3 Fig.4 Switch Terminal Connections Clamping Toremove knockouts:Place screwdriver at Bre akout thin se ctionof cove rwhe n Plate Terminal, inside edgeofknockouts,notinthecenter. wiring both switches from one conduit ilentrance. - ♦ �% INCO�I�G ndi3Old� IV C y DCG.#1146-16 �!.4 1�'- 4.51Nri$:,i I A WARNING Oj (�• Anumnsulatedsectionof asm leconductorshouldnotbeloo ed owe„�. r �i.. around the terminal and se rveas two separate connections. The �, I II�� wire must be severed,thereby providing supervision of the NOTICE /�` connection in the event that the wire be comedislodged from unde r the terminal. Failure to sever the wire may render the de vice Do not drill into the base as this creates cl'Nille— DWG.1146-13 inoperable risking se ve reproperty damage and loss of life. me talshavings which can createDo not strip wire beyond 3/8"of leng thor expose an uninsulated electrical hazards and damage the ' conductor beyond the e dgeof the terminal block.Whe nusing device Drilling voids the warranty. stranded wire,capture all strands under the clamping plate. CONNECTOR Connections 5 Typical Electrical l onnections NEUTRAL FROM 2'1 BREAKER NEUTRAL FROM BELL OBELL, :4 1 GI .1 )BREAKER mYi1 I ! 1LINE FROM BREAKER �.�i Notes: EOL(End Or Line Resistor) 1. TheModelVSRhastwoswitchesonecanbeusedtooperateacentral i'72.7 station,proprietary or remote signaling unit,while the other contact It= is used to operate a local audible or visual annunciator. 2. For supervised circuits,see"SwitchTerminal Connections" +,c+�(; +>I:+:,c+> JL4=J..1��I �� drawing and warning note(Fig.4). M■� NOTE: When c onnec Lingo a UL Listed ntrolpanel,use the panel's resistor value for c ire uiBupervision. Ti!R •rr� 1 I,Ilii lf_1l��iIR1 i PSI 0-ice len- um 11 11111 um Testing The frequency of inspe ctiomndtesting forthe Mode 1VSR and its associated protective monitoring syste mshallbe in accordance with applicable NFPACodes and Standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently). If provided,the inspector's test valve shall always be used f ortest purposes.If there are no provisions fortesting the operationof the flow detection device on the system,application of the VSR is not recommended or advisable. A minimum flow of 10 GPM(38 LPM)is required to activate this device. NOTICE Advise the person responsible for testing of the fire prote ction system that this system must be tested in accordance with the to sting instructions. Fig.6 Mounting Dimensions 5.56in Fig.7 3.50 in 2.00 in (141.2 mm) (89.0 mm) (50.8 mm) GREEN GROUND SCREWS (5934m2.4 m)����� SII .....[17 UI;IAip1 PIPE DIA. ��il,����1��. U-BOLT NUT +5.25 in •��alto -- U-BOLT WASHER EN'-`...I (+133.4 mm) �/l AU I� �I Z PIPE SADDLE lir 1 ,ik, • 9iwir _ a I :t.---.17-- . 0 PIPE • 11 O(E.i!i.!O 011, MI ,1�1\I RF i��i�i1n'L�i,� IliPLASTICPADDL , It_ �i1= ;1 I'ewu .'aa,a - III U-BOLT NOMINAL PIPE DIA.+1.75in(+44.5 MM)FOR DN 50-DN 65 2-2.5 in IIIIIIIIII lull it NOMINAL PIPE DIA.+2.125in(+54.0 MM)FOR DN 80-DN 200 3-8 in DWG 1146-15 PRINTED IN USA MFG.#5401146-REV M PAGE 3 OF 4 11/15 VSR P POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable.In the unlikely event that either component does not perform properly,please order replacement retard switch assembly stock#1029030(see Fig.8).There is no maintenance required,only periodic testing and inspection. Retard/Switch Assembly Replacement(Se e Fig.8) NOTICE The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterflow switch from the pipe 1. Make sure the fire alarmzone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the powe r source for local bell(if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Removethe(2)mounting screws holding retard/switch assembly to the base.Do not removethe(2)retard housing screws. 5. Removethe retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly.Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re-install the(2)original mounting screws. 8. Reconnect all wires.Perform a flow test and place the system back in service. Fig.8 REMOVE(2)ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLYTO BASE BREAKOUTTHINSECTIONOFCOVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2)ORIGINAL MOUNTING CREWS RETARD/SWITCH ASSEMBLY mime PIN 407 11 ilk i(rEiN trim' iimmq \.��`,ry -11 (2)LOCATING PINS/ , - I GN% LOCATING SIN 1'l. \- DO NOT REMOVE I `f ':- BOSSES IN BASE (2)RETARD HOUSING I SCREWS r /w'1►�1��% .: BASE/c4i �■� ,� r ,�, DWG#1146-10 Removal of Waterflow Switch • To prevent accidental water damage,all control valves should be shut tig htand the system completely drained before waterflow detectors are re move dor replaced. • Turnoffelectrical power to the detector,then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enoug hto g etyour fingers under it. With your fingers,roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. PRINTED IN USA MFG.#5401146-REV M PAGE4 OF 4 11/15 Bull Moose Industries BULL ]'/[DOSE® TUBE (http://www.bullmoosetube.com) (http://www.bullmoosetube.com/products-servicesproductshollow- structural-section-hss/stratusteel) LTi ATIJ T 'Jretak1nghigh trei th, �rghtweight Steel to Dew heights- Call 800.325.4467 Contact Us (/companv/contact-us) Search MENU HOME(/) PRODUCTS&SERVICES(/PRODUCTS-SERVICES) PRODUCTS(/PRODUCTS-SERVICES/PRODUCTS) SPRINKLERPIPE Sprinkler Pipe Trust Bull Moose®when it comes to protecting your most valuable assets. As the leading manufacturer of steel sprinkler pipe for fire suppression we understand that there are no second chances in fire suppression. You need products of enduring quality,reliable service and products ' of exceptional strength.You need Bull Moose. Bull Moose Advantages • UL listed(US& Canada)and FM approved • ASTM A135 and A795 Type E, Grade A Certified • Complies with NFPA-13,13R and 14 • Industry-leading hydraulic characteristics • All pipe NDT weld testing • CRR of 1.0 and greater • Exclusive maker of painted red Reddi-Pipe® • Custom lengthoptions • Products(/products-services/products) • Hollow StructuralSection(HSS)(/products-services/products/hollow-structural-section-hss) o Mechanical Steel Tube(/products-services/products/mechanical-steel-tube) O Sprinkler Pipe(/products-services/products/sprinkler-pipe) ■ Reddi-Pipe(/products-services/products/sprinkler-pipe/reddi-pipe) • Sery ices(/products-services/services) • Quality(/products-services/quality) • R&D(/products-services/rd) (http://www.bullmoosetube.com/products-services/products/sprinkler-pipe/reddi-pipe) 1110 REDDI-PIPE 5prinitler pipe finished in BLACK of RED,ready to rise © 2016 Bull Moose TubeCompany.A division of Bull Moose Industries. VicoWorldwide Fire Protection Contacts www.tyco-fire.com Products Series EC-8 — 8.0K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General corrosive atmospheres. Consequent- ly, it is recommended that the end Description user be consulted with respect to the . p suitability of these corrosion resistant The Series EC-8 Extended Cover- coatings for any given corrosive envi- age Pendent Sprinklers are decora • ronment.The effects of ambient tem- ,,, tive glass bulb sprinklers designed perature,concentration of chemicals, ;+. for use in light hazard occupancies. and gas/chemical velocity,should be They are intended for use in automatic considered, as a minimum, along with sprinkler systems designed in accor the corrosive nature of the chemical to dance with standard installation rules which the sprinklers will be exposed. , (e.g., NFPA 13) for a maximum cover- age area of 400 ft2 (37,2 m2), as corn- NOTICE • pared to the maximum coverage area The Series EC-8 Extended Coverage of 225 ft2 (20,6 m2) for standard cov- Sprinklers described herein must be 1 erage sprinklers used in light hazard installed and maintained in compli- occupancies. ance with this document, as well as The recessed version of the EC-8, in- with the applicable standards of the tended for use in areas with a finished National Fire Protection Association, ceiling, uses either the two-piece in addition to the standards of any oth- t Style 30 or 40 Recessed Escutcheon. er authorities having jurisdiction. Fail- , - .51 The Style 30 Recessed Escutcheon ure to do so may impair the perfor provides up to 1/2 inch (12,7 mm) of mance of these devices. { J total adjustment from the flush pen- The owner is responsible for main- . dent position, whereas, the Style 40 taining their fire protection system provides 3/4 inch (19,1 mm) of verti- and devices in proper operating con- cal adjustment from the flush pendent dition. Contact the installing contrac- position. The adjustment provided by tor or product manufacturer with any , „ the Recessed Escutcheons reduces questions. 'Cr . the accuracy to which the fixed pipe drops to the sprinklers must be cut. Sprinkler Corrosion resistant coatings, where IdentificationPipe Thread Connection applicable, are utilized to extend the3/4 inch NPT life of copper alloy klers beyond Number (SIN) that which would otherwise be ob- Discharge Coefficients tained when exposed to corrosive at- K=8.0 gpm/psi1/2 mospheres. Although corrosion resis- TY4232-Pendent, 8.0K (115,2 Ipm/bar1/2) tant coated sprinklers have passed TY4232 is a re-designation for C4232 Temperature Ratings the standard corrosion tests of the ap- plicable approval agencies, the test- Technical 135°F(57°C)and 155°F(68°C) ing is not representative of all possible Finish Data Sprinkler: Refer to Table A IMPORTANT Approvals Recessed Escutcheon: Natural Brass, Always refer to Technical Data UL and C-UL Listed. Signal White,Chrome Plated Sheet TFP700 for the "INSTALLER FM Approved Physical Characteristics WARNING" that provides cau- NYC Approved. tions with respect to handling (Refer p pp Buttonrame Bronze and installation of sprinkler sys- to Table A for complete approv- Bronze rns and components.serilm ro al information including corrosion re- Sealing Assembly Beryllium Nickel teImprop- sistant status.The Approvals apply to w/TEFLON er handling and installation can Bulb Glass(3 mm dia.) permanently damage a sprin- the service conditions indicated in the Compression Screw Bronze kler system or its components Design Criteria section.) Deflector Brass and cause the sprinkler to fail Maximum WorkingPressure to operate in a firesituation or cause 175 psi(12,1 bar) it to operate prematurely. Page 1 of 6 DECEMBER 2014 TFP223 TFP223 Page 2 of 6 Components: 3/4" ESCUTCHEON PLATE 1 Frame NPT** SEATING SURFACE 1 \2 - Button � r t 3 - Sealing Assembly 4 - Bulb 2 5 - Compression G%I 2-1/8" Screw 3 ,—) A • . f (54,0 mm) 6 - Deflector* t= 1/2" (12,7 mm) *Temperature rating is 4 NOMINAL36,5 indicated on Deflector. MAKE-IN _ ( mm) **Pipe thread 5 m. connections per ISO -=�� s—= - 7-1 can be provided 6* on special request. FIGURE 1 SERIES EC-8(TY4232) EXTENDED COVERAGEPENDENTSPRINKLER I SPRINKLER F INISH(See Note 4) HAZARD TYPE TEMP. BULB LIQUID NATURAL CHROME POLYESTER* BRASS PLATED Light 135°F(57°C) Orange Pendent 1, 2,3,5 155°F(68°C) Red Refer to Table B for UL and C-UL 135°F 57°C O Sensitivity Rating Rec.Pendent (57°C) Orange g 1, 2,3,5 and w/Style 30 Esc. 155°F(68°C) Red Refer to Table C for F M Sensitivity Rating Rec.Pendent 135°F(57°C) Orange w/Style 40 Esc. 1, 2,5 155°F(68°C) Red NOTES: 1. Listed by Underwriters Laboratories, Inc.(UL). 2. Listed by Underwriters Laboratories, Inc.for use in Canada(C-UL). 3. Approved by Factory Mutual Research Corporation(FM). 4. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. 5. Approved by the City of New York under MEA 113-04-E. °Frame and Deflector only. TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) Operation UL and C-UL Listing Requirements FM Approval Requirements 1. The Series EC-8 Sprinklers may be The Series EC-8 Extended Coverage The glass bulb contains a fluid that ex- used for the coverage areas shown Sprinklers are to be installed in ac- pands when exposed to heat. When in Table D, based on maintaining cordance with the applicable Factory the rated temperature is reached, the the minimum specified flow rate Mutual Loss Prevention Data Sheet. fluid expands sufficiently to shatter as a function of coverage area and Information provided in the FM Loss the glass bulb, allowing the sprinkler hazard group for all of the sprin- Prevention Data Sheet relate to, but to activate and flow water. klers in the design area. are not limited to, hydraulic design, 2. With respect to heat sensitivity,the ceiling slope and obstructions, mini- Design Series EC-8 Sprinklers can be used mum and maximum allowable spac- with unobstructed construction ing, and deflector-to-ceiling distance. Criteria consisting of flat, smooth ceilings (including bar joists) with a maxi- The Series EC-8 Extended Cover- mum pitch of one in six as defined age Pendent Sprinklers must only be and permitted byNFPA 13. installed in accordance with the ap- 3. The minimum allowable spacing plicable UL and C-UL Listing or FM between the Series EC-8 Sprin- Approval requirements as indicated klers, to prevent cold soldering, is below. Only the Style 30 or 40 Re- 8 ft. (2,4 m). cessed Escutcheon is to be used for 4. The Series EC-8 Sprinklers are recessed installation, as applicable to be installed in accordance with (Ref.Table A, B,and C). all other requirements of NFPA 13 for extended coverage pendent sprinklers. TFP223 Page 3 of 6 Area Style 135°F(57°C) 155°F(68°C) Installation 16 x 16 Pendent QR QR The Series EC-8 Sprinklers must 16 x 16 Style 30 Recessed QR QR be installed in accordance with this - — — section. 16 x 16 Style 40 Recessed QR QR General Instructions 18 x 18 Pendent QR QR Do not install any bulb type sprinkler - 18 x 18 Style 30 Recessed OR SR if the bulb is cracked or there is a loss 18 x 18 Style 40 Recessed OR SR of liquid from the bulb.With the sprin- kler held horizontally,a small air bub- 20 x 20 Pendent OR SR ble should be present. The diameter 20 x 20 Style 30 Recessed QR SR of the air bubble is approximately 1/16 inch (1,6 mm). 20 x 20 Style 40 Recessed SR SR A leak tight 3/4 inch NPT sprinkler QR:Quick Response joint should be obtained with a torque SR:Standard Response of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). TABLE B Higher levels of torque may distort the SENSITIVITY RATING FOR UL AND C-UL LISTING sprinkler inlet with consequent leak- OF SERIES EC-8 SPRINKLERS age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment of an escutch- Area Style 135°F(57°C) 155°F(68°C) eon plate by under-or over-tightening 16 x 16 Pendent QR QR the sprinkler. Re-adjust the position of - 16 x 16 Style 30 Recessed QR N/A the sprinklerfitting to suit. 16 x 16 Style 40 Recessed N/A N/A Step 1. The sprinkler must be in- stalled with the deflector parallel to 18 x 18 Pendent QR QR the mounting surface. Pendent sprin- ts x 18 Style 30 Recessed QR N/A klers must be installed in the pendent position. 18 x 18 Style 40 Recessed N/A N/A Step 2. After installing the Style 30 or 20 x 20 Pendent QR QR 40 mounting plate(or other escutch- 20 x 20 Style 30 Recessed QR N/A eon, as applicable) over the sprinkler pipe threads, and with pipe thread 20 x 20 Style 40 Recessed N/A N/A sealant applied to the pipe threads, QR:Quick Response hand tighten the sprinkler into the SR:Standard Response sprinklerfitting. N/A:Not Applicable Step 3.Wrench tighten pendent sp rin- TABLE C klers using only the W-Type 3 (End A) SENSITIVITY RATING FOR FM APPROVAL Sprinkler Wrench. Wrench tighten the OF SERIES EC-8 SPRINKLERS recessed pendent sprinklers using only the W-Type 23 Sprinkler Wrench. The wrench recess of the applicable Description Area GPM PSI sprinkler wrench (Ref. Figures 4 and 5) is to be applied to the sprinkler 16 x 16 26 10.6 wrench flats(Ref.Figure 1). TY4232(K=8.0) 18 x 18 33 17.0 Pendent 20 x 20 40 25.0 1 ft=0.3048 m 1 ft2=0.093 m2 1 gpm=3.785 1pm 1 psi=0.06895 bar 1 gpm/ft2=40.74 mm/min TABLE D FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS TFP223 Page 4 of 6 2-7/8"DIA. "FITTING SIDE" 7/16±1/8" (73,0mm) 1/2" (12,7 mm) TOWARDS SPRINKLER (11,1±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FITTING FACEOF (57,2 mm) SPRINKLERING ,2m1/8" ) ,�\ FITTING (3,2mm) f �� I 1WRENCH u1 / RECESS �� 'I (END..A..) MOUNTING 1101" MOUNTING FIGURE4 SURFACE PLATE W-TYPE 3 CLOSURESPRINKLER WRENCH 1-5/16" (33,3mm) 1-1/16" (27,0 mm) WRENCH RECESS FIGURE2 0 SERIES EC-8 RECESSED PENDENTSPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT E- i (7) STYLE30 RECESSED ESCUTCHEON _ 2-7/8"DIA. I 9/16±1/4" (73,0 mm) — ~ 3/4"(19,1 mm) (14,3±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) 0 4.1 0 FACE O F (57,2 mm) j SPRINKLER 1/8" --1 FITTING (3,2 mm) 1 1iff 1 / 1 FIGURE5 I lI h= 1 W-TYPE 23 RECESSED \ If SPRINKLER WRENCH MOUNTING corrosion resistant coating. Thereaf- SURFACE MOUNTING PLATE ter, annual inspections per NFPA 25 CLOSURE —� should suffice; however, instead of in- specting from the floor level,a random 1-5/16" (33,3 mm) sampling of close-up visual inspec- 13/16" (20,6 mm) tions should be made, so as to better FIGURES determine the exact sprinkler condi- SERIES EC-8 RECESSED PENDENTSPRINKLER ASSEMBLY tion and the long term integrity of the WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT corrosion resistant coating, as it may STYLE40 RECESSED ESCUTCHEON be affected by the corrosive condi tions present. Care and wise altered after leaving the factory. The owner is responsible for the in Modified sprinklers must be replaced. spection, testing, and maintenance Maintenance Sprinklers that have been exposed to of their fire protection system and de- corrosive productsofcombustion,but vices in compliance with this docu- The Series EC 8 Sprinklers must be have not operated,should be replaced ment, as well as with the applicable p if they cannot be completely cleaned standards of the National Fire Pro maintained and serviced in actor- tection Association(e.g., NFPA in dance with this section. by wiping the sprinkler with a cloth or ) by brushing it with a soft bristle brush. addition to the standards of any oth Before closing a fire protection system er authorities having jurisdiction. The main control valve for maintenance Care must be exercised to avoid dam- installing contractor or sprinkler man- work on the fire protection system that age to the sprinklers before, during, ufacturer should be contacted relative it controls, permission to shut down and after installation. Sprinklers dam to any questions. the affected fire protection systems aged by dropping, striking, wrench y twist/slippage, or the like, must be It is recommended that automatic must be obtained from the proper au- replaced. Also, replace any sprinkler sprinkler systems be inspected, test- thorities and all personnel who may that has a cracked bulb or that has ed, and maintained by a qualified In- be affected by this action must be lost liquid from its bulb.(Ref. Installs spection Service in accordance with notified. tion Section.) local requirements and/or national Sprinklers that are found to be leaking codes. or exhibiting visible signs of corrosion Frequent visual inspections are ret must be replaced. ommended to be initially performed for corrosion resistant coated sprin- Automatic sprinklers must never be klers, after the installation has been painted, plated, coated, or other- completed,to verify the integrity of the TFP223 Page 5 of 6 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributorforavail- ability. When placing an order, indi- cate the full product name and Part Number(P/N). SprinklerAssemblies with NPT Thread Connections Specify:Series EC-8(TY4232), K=8.0, Extended Coverage (Light Hazard) Pendent Sprinkler, (specify) tem- perature rating, (specify) finish, P/N (specify): 135°F(57°C) Natural Brass PSN 50-801-1-135 Signal White(RAL9003) Polyester PSN 50-801-4-135 Chrome Plated PSN 50-801-9-135 155°F(68°C) Natural Brass PSN 50-801-1-155 Signal White(RAL9003) Polyester PSN 50-801-4-155 Chrome Plated PSN 50-801-9-155 Recessed Escutcheon Specify:Style(30 or 40) Recessed Es- cutcheon with (specify*) finish, P/N (specify*) `Refer to Technical Data Sheet TFP770 SprinklerW rench Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 23 Recessed Sprin- kler Wrench,P/N 56-000-6-838 TFP223 Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products, LP. All rights reserved. tyco TEFLON is trademark of The DuPont Corporation Fire Protection Products VicoWorldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRL — 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The Series TY-FRL Sprinklers de- Description e Description scribed herein must be installed and maintained in compliance with this The TYCO Series TY-FRL, 2.8, 5.6, document, as well as with the appli- and 8.0 K-factor, Upright and Pendent cable standards of the National Fire Sprinklers described in this data sheet Protection Association,in addition to are quick response, standard cover- the standards of any other authorities age, solder type spray sprinklers de- having jurisdiction. Failure to do so signed for use in light and ordinary may impair the performance of these hazard commercial occupancies such devices. " as banks, hotels, shopping malls, The owner is responsible for main- schools,hosp itals,etc. taining their fire protection system The recessed version of the 2.8 and and devices in proper operating con- 5.6 K-factor, Series TY-FRL Pendent dition.Contact the installing contrac- Sprinkler, where applicable, is intend- tor or sprinkler manufacturer with any ed for use in areas with a finished ceil- questions. ing. It uses a two-piece Style 20 (1/2 inch NPT) Recessed Escutcheon.The Recessed Escutcheon provides 1/4 Sprinkler inch (6,4 mm) of recessed adjustment Identification or up to 1/2 inch (12,7 mm) of total ad- justment from the flush pen Numbers dent position. The adjustment provid- ed by the Recessed Escutcheon re- TY1121 Upright 2.8K, 1/2"NPT duces the accuracyto which the fixed TY1221 . . . . Pendent 2.8K, 1/2"NPT _� ,� � , pipe drops to the sprinklers must be TY3121 Upright 5.6K,1/2"NPT cut. TY3221 . . . . Pendent 5.6K,1/2"NPT An intermediate level version of the TY4121 Upright 8.0K,3/4"NPT 5.6 and 8.0 K-factor, Series TY-FRL TY4221 . . . . Pendent 8.0K,3/4"NPT Pendent Sprinkler can be obtained TY1121 is a redesignation for S1879 by utilizing the Series TY-FRL Pen- and G8973. dent Sprinkler in combination with the Model S4 Shield. TY1221 is a redesignation for S1880 and G8971. TY3121 is a redesignation for S1864 and G8974. TY3221 is a redesignation for S1865 and G8972. TY4121 is a redesignation for S1866 and G8174. IMPORTANT TY4221 is a redesignation for S1867 and G8172. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler sys- tems and components. Improp- er handling and installation can permanently damage a sprin- kler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 OCTOBER 2013 TFP130 TFP130 Page 2 of 6 *Temperature rating ** Pipe thread connections per 1 - Frame 5 - Link 7 - Button is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Strut Assembly 8 - Seal Deflector. special request. PLATE SEATING 3 - Deflector* 6 - Ejection 9 - Bushing DEFLECTOR* SURFACE 4 - Hook Spring . �_�_"1_R1�< 1 I�' WRENCH 1 2-11/16" 7M --- (68,3 i �i� AREA �� 8 (68,3 mm) • _ �� �� �+ :it h2-11/16"7/16" 1 _�1 (68,3 mm) ���_/j 6 _���� N10M NAL ���� 2" ���� fi .0„ 7 10 l� �J 2 I��� MAKE IN (50,8 mm2-)11/16" m) • / _ STYLE 2 0 RECESSED .=1 4 ESCUTCHEON 1/2"NPT** WRENCH DEFLECTOR* 2-7/8"(73,0 mm)DIA. .. 3* FLANGES UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRL UPRIGHT(TY1121)AND PENDENT(TY1221)SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT *Temperature rating ** Pipe thread connections per 1 - Frame 5 - Link 7 - Button is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Strut Assembly 8 - Seal Deflector. special request. PLATE SEATING 3 - Deflector* 6 - Ejection DEFLECTOR* SURFACE 4 - Hook Spring 1 mr��id ,I�o Ju.r. 2-11/16" Ww. AREAH ' 8 (68,3 mm) »U �. 4 �r r 1 2 11/16" r 1 6 r' `1 7/16" �� ��� _o' 7 1 1 (68,3 mm) �� I -�* �, —�� (11,1 mm) ````�► ll``�►//�� rp 1� � NOMINAL 2.' l% 5 11 2 M E MAKE IN (50,8 ---=----- m2-)11/16" m) / I = 1 STYLE 2 0 1 RECESSEDI 4 a 4 i ESCUTCHEON 1/2"NPT** WRENCH DEFLECTOR* 2-7/8"(73,0 mm)DIA. 3* FLANGES UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRL UPRIGHT(TY3121)AND PENDENT(TY3221)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT TFP130 Page 3 of 6 DEFLECTOR* CEILING PLATE 1 - Frame 6 - Ejection SEATING SURFACE 2 - Strut Spring ft Ar 3 Deflector* 7 Button rol 1 4 - Hook 8 - Seal WRENCH 5 - Link 213/16" AREA 8 Assembly (71,4 mm) 1/2 (. ..1.) 2 15/16" �_ 1- -101 7 *Temperature rating is i WIN (1217/2m" 127 mm) (74,6 mm) 6 - * indicated on Deflector. NOMINAL Id 4 MAKE-IN(-) 2-3/16" 0 2 ** ME (55,6 mm) 5 Pipe thread connections = i TO per ISO 7-1 can be d 4 provided on special . 04 request. \ 1 /.___ ___.. 1 1 —�`�— 3 3/4"NPT** WRENCH DEFLECTOR* FLANGES UPRIGHT PENDENT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRL UPRIGHT(TY4121)AND PENDENT(TY4221)SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Technical Operation Installation Data The fusible link(heat collector)assem- The TYCO Series TY-FRL Sprinklers bly is comprised of two halves that must be installed in accordance with Approvals are joined together by a thin layer of this section. UL and C-UL Listed. FM, NYC, and solder. When the rated temperature A leak tight 1/2 inch NPT sprinkler LPCB Approved.(Refer to Table A for is reached, the solder melts and the joint should be obtained with a torque complete approval information includ- two link halves separate, allowing the of 7 to 14 ft./lbs. (9,5 to 19,0 Nm). A ing corrosion resistant status.) sprinkler to operate. leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 Maximum Working Pressure Design Criteria to 20 ft./lbs.(13,4 to 26,8 Nm). Higher 175 psi(12,1 bar) The TYCO Series TY-FRL Pendent levels of torque may distort the sprin- kler inlet and cause leakage or impair- Discharge Coefficient and Upright Sprinklers are intended ment of the sprinkler. K=2.8 GPM/ps712 (40,3 LPM/bar1I2) for fire protection systems designed in K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) accordance with the standard instal- Do not attempt to make-up for insuf- K=8.0 GPM/psi112 (115,2 LPM/bar112) lation rules recognized by the appli- ficient adjustment in the escutcheon cable Listing or Approval agency(e.g., plate by under-or over-tightening the Temperature Ratings UL Listing is based on the require- sprinkler. Readjust the position of the Refer to Table A ments of NFPA 13, and FM Approval sprinkler fitting to suit. is based on the requirements of FM's Series TY-FRL Pendent and Upright Finishes Loss Prevention Data Sheets). Only Sprinkler Installation Sprinkler:Refer to Table A the Style 20 Recessed Escutcheon,as applicable, is to be used for recessed The Series TY-FRL Pendent and Up- Recessed Escutcheon:White Coated, pendent installations. right Sprinklers must be installed in Chrome Plated,or Brass Plated accordance with this section. Physical Characteristics Step 1. Pendent sprinklers are to be Frame installed in the pendent position, and Strut BronzeMonel upright sprinklers are to be installed in the upright position. Deflector Bronze Hook Monel Step 2. With pipe thread sealant ap- Link Assembly Nickel plied to the pipe threads,hand tighten Ejection Spring Inconel the sprinkler into the sprinkler fitting. Button Bronze Step 3. Tighten the sprinkler into the Seal TEFLON sprinkler fitting using only the W-Type Bushing(2.8K only) Brass 9 Sprinkler Wrench (Ref. Figure 6). With reference to Figures 1, 2, and 3, the W-Type 9 Sprinkler Wrench is to be applied to the wrench area. TFP13O Page 4 of 6 SPRINKLER FINISH Series TY-FRL Recessed Pendent Sprinkler Installation K TYPE TEMP. FRAME NATURAL CHROME RATING COLOR BRASS PLATED The Series TY-FRL Recessed Pendent CODE Sprinklers must be installed in accor- 165°F(74°C) Unpainted accor- dance with the following instructions. PENDENT Step A. After installing the Style 20 (TY1221) 212°F(100°C) White Mounting Plate, as applicable, over 2.8 UPRIGHT 165°F(74°C) Unpainted the sprinkler threads and with pipe 1/2" (TY1121) — 1, 2,5 thread sealant applied to the pipe NPT 212°F(100°C) White threads,hand tighten the sprinkler into RECESSED 165°F(74°C) Unpainted the sprinkler fitting. PENDENT Step B. Tighten the sprinkler into the (TY1221 w/Style 20) 212°F(100°C) White sprinkler fitting using only the W-Type PENDENT 165°F(74°C) Unpainted 1, 2,3,4,5 12 Recessed Sprinkler Wrench (Ref. (TY3221) Figure 7). With reference to Figure 1, 212°F(100°C) White 1,2,3,5 or 2, the W-Type 12 Recessed Sprin- 5.6 UPRIGHT 165°F(74°C) Unpainted 1, 2,3,4,5 kler Wrench is to be applied to the 1/2" (TY3121) sprinkler wrenching flanges. NPT 212°F(100°C) White 1,2,3,5 Step C. After the ceiling has been in- RECESSED 165°F(74°C) Unpainted stalled or the finish coat has been ap- PENDENT 1, 2,5 plied, slide on the Style 20 Escutch- (TY3221 w/Style 20) 212°F(100°C) White eon over the Series TY-FRL Sprinkler PENDENT 165°F(74°C) Unpainted and push the Escutcheon over the (TY4221) Mounting Plate until its flange comes 8.0 212°F(100°C) White in contact with the ceiling. 3/4" 1, 2,3,5 NPT UPRIGHT 165°F(74°C) Unpainted (TY4121) 212°F(100°C) White NOTES: (1) Listed by Underwriters Laboratories,Inc.(UL)as Quick Response Sprinklers (2) Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL)as Quick Response Sprinklers. (3) Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. (4) Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/03)as Quick Response Sprinklers. (5) Approved by the City of New York under MEA 112-04-E. TABLE A LABORATORY LISTINGS AND APPROVALS TFP13O Page 5 of 6 1/2±1/8" 2-7/8"DIA. 1/2" (12,7 mm) / (12,7±3,2 mm) (73,0 mm) 1/4" (6,4 mm) FACE OF 2-1/4" DIA. MOUNTING SPRINKLER (57,2 mm) PLATE FITTING 1/8" WRENCH iii 1 — — I (3,2 mm) RECESS } \ 1� FIGURE 6 MOUNTING W-TYPE 9 SPRINKLER SURFACE 1-3/4" (44,5 mm) WRENCH 1-1/2" (38,1 mm) li < CLOSURE TY-FRL _�- WRENCH FIGURE 4 RECESS SERIES TY-FRL (TY1221)RECESSED PENDENT SPRINKLER t 1 ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT lit 1/2±1/8" 2-7/8"DIA. 1/2" (12,7 mm) % t (12,7±3,2 mm) (73,0 mm) 1/4" (6,4 mm) FACE OF 2-1/4" DIA. MOUNTING III SPRINKLER (57,2 mm) PLATE FITTING PUSH WRENCH UP TO 1/8" ENSURE ENGAGEMENT 1 / I _ (3,2 mm) WITH SPRINKLER = J --r�� 1 WRENCHINGAREA —/ [ i FIGURE 7 W-TYPE 12 RECESSED MOUNTING I SPRINKLER WRENCH SURFACE 1-3/4" (44,5 mm) 1-1/2" (38,1 mm) CLOSURE TY-FRL":___ ___2" FIGURE 5 SERIES TY-FRL(TY3221)RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT Care and Sprinklers that are found to be leaking tection Association (e.g., NFPA 25), in or exhibiting visible signs of corrosion addition to the standards of any oth- Maintenance must be replaced. er authorities having jurisdiction. The Automatic sprinklers must never be installing contractor or sprinkler man- The TYCO Series TY-FRL Sprinklers painted, plated, coated or otherwise ufacturer should be contacted relative must be maintained and serviced in altered after leaving the factory.Mo di- to any questions. accordance with this section. fied or over-heated sprinklers must be It is recommended that automatic Before closing a fire protection sys- replaced. sprinkler systems be inspected, test- tern main control valve for mainte- Care must be exercised to avoid darn- ed, and maintained by a qualified In - ed work on the fire protection sys- age to the sprinklers -before,during, spection Service in accordance with tern that it controls,permission to shut and after installation. Sprinklers dam- local requirements and/or national down the affected fire protection sys- aged by dropping, striking, wrench codes. tern must be obtained from the prop- twist/slippage, or the like, must be er authorities and all personnel who replaced. may be affected by this action must The owner is responsible for the in- be notified. spection, testing, and maintenance Absence of an escutcheon, which is of their fire protection system and de- used to cover a clearance hole, may vices in compliance with this docu- delay the time to sprinkler operation in ment, as well as with the applicable a fire situation. standards of the National Fire Pro- TPF13O Page 6 of 6 • P/N 58 - XXX - X - XXX I I SIN SPRINKLER TEMPERATURE RATING 973 2.8K UPRIGHT(1/2"NPT) TY1121 1 NATURAL BRASS 165 165°F(74°C) 981 2.8K PENDENT(1/2"NPT) TY1221 9 CHROME PLATED 212 212°F(100°C) 974 5.6K UPRIGHT(1/2"NPT) TY3121 982 5.6K PENDENT(1/2"NPT) TY3221 174 8.0K UPRIGHT(3/4"NPT) TY4121 172 8.0K PENDENT(3/4"NPT) TY4221 TABLE B SERIES TY-FRL PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name and Part Number(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRL (specify SIN), (specify K-factor), (specify Up- right, Pendent, or Recessed Pendent) Sprinkler Quick Response, (specify) temperature rating, (specify type of finish), P/N(sp ecify from Table B) Recessed Escutcheon Specify: Style 20 Recessed Es- cutcheon with (specify*) finish, P/N (specify*) *Referto Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 9 Sprinkler Wrench, P/N 56-000-1-849 Specify:W-Type 12 Sprinkler Wrench, P/N 56-798-1-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2013 Tyco Fire Products, LP. All rights reserved. t/ co TEFLON is trademark of The DuPont Corporation. Fire Protection Products