Loading...
HomeMy WebLinkAbout4273cddr1.pdf West Slope Testing & Inspection LLC Report #1 3177 Glendam Dr. Grand Junction, CO 81504 Page 1 of 1 Phone: 970-434-6988 Cell: 970-260-2844 Inspection Report Date: 8-1-18 Project: 4273 Columbine Dr. Duplex Address: 4273 Columbine Dr. Vail, CO Building Permit No's: B17-0421 & B-17-0422 General Contractor: Mountain Top Homes Inspection of shop fabrication or field work at job site: Field Report: Visually inspected field welding at the plate type steel frame moment connections, tube steel connection plates, and inspected high strength A325 bolting at the steel beam & column connections. Note onsite welding & bolting was inspected as best as possible at this stage of the construction with wood framing, packing, plating, and exterior sheathing in place. The field welding & high strength A325 bolting inspected above appeared to be in general conformance with the plans, and the quality requirements of the AWS D1.1 Structural Welding Code & the AISC/RCSC Specification for high strength bolting. Douglas F.Young Certification#5102224 N tural Weld in pecial l e , r Inspector/Technician: Douglas E Young • tural teel olting a 'a In ,ector - d Fi roofing Spe.f.1 i spector ' ' , Douglas E Young ..,.j ld` S CWI 96070131 `` QC1 EXP. 7/1/2020