HomeMy WebLinkAbout4273cddr1_1.pdf West Slope Testing & Inspection LLC Report #1
3177 Glendam Dr.
Grand Junction, CO 81504 Page 1 of 1
Phone: 970-434-6988
Cell: 970-260-2844
Inspection Report
Date: 8-1-18
Project: 4273 Columbine Dr. Duplex
Address: 4273 Columbine Dr. Vail, CO
Building Permit No's: B17-0421 & B-17-0422
General Contractor: Mountain Top Homes
Inspection of shop fabrication or field work at job site: Field
Report: Visually inspected field welding at the plate type steel frame moment
connections, tube steel connection plates, and inspected high strength A325
bolting at the steel beam & column connections. Note onsite welding & bolting
was inspected as best as possible at this stage of the construction with wood
framing, packing, plating, and exterior sheathing in place.
The field welding & high strength A325 bolting inspected above appeared to be
in general conformance with the plans, and the quality requirements of the AWS
D1.1 Structural Welding Code & the AISC/RCSC Specification for high strength
bolting.
Douglas F.Young
Certification#5102224
N tural Weld in pecial l e , r
Inspector/Technician: Douglas E Young • tural teel olting a 'a In ,ector
- d Fi roofing Spe.f.1 i spector
' ' , Douglas E Young
..,.j ld` S CWI 96070131
`` QC1 EXP. 7/1/2020