HomeMy WebLinkAboutmvpu3r2_1.pdf West Slope Testing & Inspection LLC Report #2
3177 Glendam Dr.
Grand Junction, CO 81504 Page 1 of 1
Phone: 970-434-6988
Cell: 970-260-2844
Inspection Report
Dates: 6-29-18 & 8-1-18
Project: Meadow Vail Place Unit 3 Remodel
Address: 44 West Meadow Dr. Vail, CO
Building Permit No: B 18-0086
General Contractor: Silich Construction
Contractor that Performed Work: Thompson Welding
Inspection of shop fabrication or field work at job site: Field
Report: Visually inspected field welding at new tube steel bracing, gusset/brace
connection plates, steel beam reinforcing, and stiffener plates level 3 & 4 framing
grid line C from 6 to 8. Also visually inspected steel deck attachment puddle
welds level 3 (low roof area) grids E to G.
The field welding inspected above appeared to be in substantial conformance
with the construction documents, and the quality requirements of the AWS
Structural Welding Codes.
Douglas E.Young
C Cer ificatio 145I 02 2,
uctu
-
uctu 1 W ting Spey 1 spe ,r
• Inspector/Technician: Douglas E Youngour Ste f&Boltg •c;; Inspector
a -applied ireproofin .p tial Inspector
\� ,, Douglas E Young
`' �' CWI 96070/3/
QC1 EXP. 7/1/2020