Loading...
HomeMy WebLinkAboutmvpu3r2_1.pdf West Slope Testing & Inspection LLC Report #2 3177 Glendam Dr. Grand Junction, CO 81504 Page 1 of 1 Phone: 970-434-6988 Cell: 970-260-2844 Inspection Report Dates: 6-29-18 & 8-1-18 Project: Meadow Vail Place Unit 3 Remodel Address: 44 West Meadow Dr. Vail, CO Building Permit No: B 18-0086 General Contractor: Silich Construction Contractor that Performed Work: Thompson Welding Inspection of shop fabrication or field work at job site: Field Report: Visually inspected field welding at new tube steel bracing, gusset/brace connection plates, steel beam reinforcing, and stiffener plates level 3 & 4 framing grid line C from 6 to 8. Also visually inspected steel deck attachment puddle welds level 3 (low roof area) grids E to G. The field welding inspected above appeared to be in substantial conformance with the construction documents, and the quality requirements of the AWS Structural Welding Codes. Douglas E.Young C Cer ificatio 145I 02 2, uctu - uctu 1 W ting Spey 1 spe ,r • Inspector/Technician: Douglas E Youngour Ste f&Boltg •c;; Inspector a -applied ireproofin .p tial Inspector \� ,, Douglas E Young `' �' CWI 96070/3/ QC1 EXP. 7/1/2020